www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

Similar documents
www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

Bus Bar Protection Relay B-PRO 4000

Transformer Protection Relay

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

Protection Relays PHASE & RESIDUAL OVERCURRENT

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

Power System Monitoring Recorder TESLA 3000

SEL-551/SEL-551C Overcurrent and Reclosing Relay

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

RT4F-110V/25A RECTIFIER

PMC 530 Series Advanced Multifunction Meter

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS

BF 79 81

Form 6 Pole Mount Microprocessor-Based Recloser Control Technical Specifications

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

Residual overvoltage relay

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Power System Monitoring Recorder

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

RT4F-120V/20A-WAC RECTIFIER

Functional specification for Form 6 pole-mount recloser control

FP-5000 Feeder Protection

QUALITROL QTMS Transformer Monitoring System

RT4F-48V/50A-WAC RECTIFIER

PMC-630 Series Advanced Multifunction Meter

RT4B-110V/12A RECTIFIER

Earth-fault Relay SPAJ 110 C. Product Guide

Power System Monitoring Recorder. Product Overview. 10 Year WARRANTY

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL Request publication Request publication

GE Multilin 350 Feeder Protection Relay Specifications

www. ElectricalPartManuals. com .Basler Electric BE1-878 HIGH IMPEDANCE BUS DIFFERENTIAL RELAY ADVANTAGES ADDITIONAL INFORMATION APPLICATION Page2

GE Power Management. MMII Intelligent MCC Controller

GRD130 - FEATURES APPLICATION

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Feeder protection relay SPAA 121 C. Product Guide

DGC-2000 DIGITAL GENSET CONTROLLER

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

BF

M-2001D DIGITAL TAPCHANGER CONTROL SUGGESTED SPECIFICATIONS

Providing the missing piece in your Condition Based Monitoring platform

CONTROLS. Digital Regulator. Digital Regulator Control for General Electric, Siemens, Cooper and Howard Regulators

Feeder/ Motor Protection Relay VAMP 40

Maximize process uptime with the SEL-patented motor thermal model.

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

POWER METER HC Features

Designed For Reliability Manufactured To Last

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

BE1-951 OVERCURRENT PROTECTION SYSTEM ADVANTAGES

MINER-S Station Controller

For Transmission, Distribution and Machinery protection.

Relion 611 series. 611 series Type Test Certificate

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

RT12-240V/2.4kW Rectifier Specification

Scout-S Station Controller

GRE130. Protection and Control for MV Systems

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Contact protection relay

A low-cost, economical solution for distribution feeder protection

SEL-587Z High-Impedance Differential and Overcurrent Relay

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Protection relay for secondary distribution

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

CSPS-6K (Shelf Type) POWER you need POWER SHELF

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

MINER-S Station Controller. Substation Automation

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

SEL-2730M 24-Port Managed Ethernet Switch

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

NPW800R RETROFITTING. Power and Volatge Protection Relay

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Using the Bitronics 70 Series to Improve Local Monitoring and Control

UW Purchase Specification Section

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems.

BE1-951 MULTIFUNCTION PROTECTION SYSTEM ADVANTAGES

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Synchro-check relay. Application

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

APR64(Rackable) APR64P (Portable)

GRD110 FEATURES APPLICATION

Transcription:

Protective Relays Electrical Apparatus Capacitor Bank Protection Relay 165-440-900 Figure 1: Edison Idea Relay The capacitor bank protection relay is a member of Cooper Power Systems Edison Idea TM line of protective relays. The is a full-featured relay suitable for shunt capacitor or filter bank protection and automatic voltage control applications. The relay is ideally suited for new or retrofit applications of fuseless or internal/externally fused banks requiring neutral unbalance protection. It utilizes voltage or current neutral unbalance to provide flexible protection for both grounded and ungrounded banks. Single or double wye bank configurations may be accommodated. The relay easily permits nulling of inherent bank unbalance and compensates for real time system unbalances (single wye) thus permitting maximum sensitivity for detection of internal problems. The relay detects capacitor unit failure when the compensated neutral quantity increases beyond a threshold. The neutral unbalance algorithms permit secure and economical protection on banks of various var ratings. The also provides advanced power quality, metering, communication, and PLC functions. The uses Cooper Power Systems ProView interface software package for PCs running the Microsoft Windows operating system. Via the IDEA Workbench feature of ProView, add additional functionality to the by means of downloadable Custom Modules obtained from Cooper Power Systems. Provide custom solutions by employing the Workbench s intuitive and graphical tools for creating, viewing and testing logic diagrams. This expandability provides a continuous upgrade path that not only protects the initial investment in the relay but also provides a means to increase the relay s functionality in response to changing protection requirements and regulatory, power quality and reliability concerns. February 2007 Supersedes November 2006 PROTECTION AND CONTROL FUNCTIONS Unbalance detection of grounded or ungrounded capacitor or filter banks using compensated neutral current (50N) or voltage (59N). Three-phase definite-time and inverse-time overcurrent fault protection (50P, 51P). Residual definite-time and inverse-time overcurrent ground fault protection (50R, 51R). Phase and neutral rms, definite-time reactor / resistor over load protection (50OL, 50NOL). Definite time overvoltage alarming, tripping and inverse time overvoltage protection (59-A, 59-T, 51V). Definite time undervoltage (27); Dead Bus Trip (DBT). Block of Close following Trip Lockout or awaiting discharge. Fuse Fail (Loss of Voltage) detection (27FF). Automatic voltage control. Breaker Failure. ADVANCED CAPABILITIES Add new functions and features using IDEA Workbench Custom Modules. Virtual Test Set : Pre-test relay protective responses and custom logic interaction using the powerful simulation module built into the Proview software. Relay Replay : Anticipate future changes to the protection environment based on historical oscillographic event data. Metering of Amps, Volts, Vars, etc: Accurately quantify system and bank health via important analog data. Sequence of Events: Quickly access logged relay responses to system or human activity via the front panel display or uploaded files. Data Profiler: Time-trend harmonic levels in and around the bank. Tailor the Profiler to trend the data important to you. ProView s relay scheme file completely documents protection and control algorithms via interactive logic diagrams; these are color-coded and come alive when viewing historical, on-line, or simulated data. Dual ports Ethernet: Easily integrate the relay into your communication network.

IDEA Capacitor Bank Protection Relay CUSTOMIZE THE WITH THE IDEA WORKBENCH The is a fully functional relay, ready to use right out of the box. However, there are applications where custom control logic, or custom functions need to be added to the relay. The IDEA Workbench is a revolutionary graphical software-programming environment provided by ProView that permits the user to customize the. Add new features or protective functions by means of IDEA Workbench Custom Modules; e.g., bank switching based on time of day or season. Through these, your investment in the relay is protected as future needs and developments are addressed. Create custom control and protection logic using over 400 programming signals and tools, all selectable from drag-off Toolboxes. Logic created using these tools can then be saved as Custom Modules to be reused or shared with associates. Figure 2: Typical Interactive Logic Diagram in ProView Monitor and control practically every aspect of the relay s operation with interactive logic diagrams. See Figure 2. View the layout of protection and control logic diagrams via the graphical interface software; observe actual binary status or analog data values while On Line, playing back events or in simulation mode. Create custom metering and measurement quantities and application-specific sequence of event records and data profiling. Configure communication protocols. Alter protocol type, ports, data rates and input / output mapping to match the needs of the application. Use the IDEA Workbench to rapidly and accurately create customized solutions by working the way the engineer thinks, via logic diagram and flowchart construction methods in a graphical environment. No equation-based or command-based logic programming is required. CAPACITOR BANK UNBALANCE PROTECTION USING NEUTRAL CURRENT (50N) OR VOLTAGE (59N), SINGLE OR DOUBLE WYE CONFIGURATION Using well-proven neutral unbalance capacitor bank protection principles, the is applicable regardless of bank grounding (ungrounded, solid or resistive / capacitive), capacitor unit fusing (external, internal or fuseless), wye configuration (single or double), or system voltage or bank var rating. Multiple levels of unbalance alarm and trip protection are provided. The inherent neutral unbalance quantity is committed to relay memory at commissioning time to compensate for capacitor tolerances. For single wye configurations, input bus voltages permit the relay to compensate for system voltage unbalances. For double wye applications where ambiguous indications are a concern, additional logic tracks self canceling can failures by preventing similar capacitor failures in both sides of the same phase from rebalancing the neutral signal. Together, these advanced features offer to the user ultimate sensitivity and permit detection of the smallest number of unit failures within the bank. OVERCURRENT PROTECTION The eliminates the need for additional relays by offering complete backup definite-time and inverse-time overcurrent protection for both phase and ground faults. The inverse-time response follows IEEE, IEC or industry standard characteristic curves. OVERLOAD PROTECTION Series-connected inrush or harmonic tuning reactors are susceptible to thermal effects due to harmonic-rich bank currents. Use the s true rms current sensing definite-time phase element to aid in harmonic overload alarm and trip protection of any reactors connected. Enable the relay s built-in neutral overload element to prevent excessive thermal stress in neutral-ground connected components, e.g., a capacitor bank neutral resistor. 2

165-440-900 UNDER, OVERVOLTAGE PROTECTION The protection response characteristic follows a piece-wise linear curve based on the IEEE STD-18 overvoltage / time point pairs. The rated voltage of the capacitor bank is the only setting for this simple but effective protective element. The inverse time overvoltage element adjusts for any voltage drop across an inrush or tuning reactor. Select between three methods to calculate equivalent capacitor voltage: Root Sum of Squares (RSS), Arithmetic Summation (Asum) or direct phase voltage inputs. The also provides definite-time overvoltage alarming and undervoltage trip protection. VOLTAGE CONTROL Use the to automatically control bus voltage by selectively operating the bank s switching device based on adjustable voltage profile thresholds and time delays. Use maximum / minimum per-phase voltage values, positive sequence magnitude, or a user-defined analog value as the controlling signal. If necessary for the application, Workbench customization permits additional switching control based on time-of-day, day-of-week, season-of-year or other criteria determined by the user. Augment the real-time control via SCADA as needed. DEAD BUS TRIP (DBT) If the capacitor bus becomes inadvertently de-energized, e.g., due to tripping of line breakers in response to a system fault, the DBT element may trip off the capacitor bank prior to any auto-reclosing. This prevents the occurrence of damaging electrical transients associated with re-energizing capacitor banks still containing trapped charge. BLOCK OF CLOSE Re-energization of capacitor banks with trapped charge causes transient overvoltages. The has logic implemented with user-settable time delays to allow decay of the trapped charge. METERING The offers extensive and high accuracy metering capabilities, including: Instantaneous Volt, Amp, Watt, vars and other quantities in primary scaled values. Demand metering with date/time stamped peak values. Harmonics metering (through the 15 th ) including THD for all voltage and all current channels. EVENT RECORDS AND ANALYSIS TOOLS The shares the same event recording and analysis tools as all Edison Idea relays. The Edison Idea allows for the display of event records in a variety of formats including waveforms (oscillography), magnitude plots, phasor diagrams, symmetrical component diagrams and more. Many of these event views are also available in On-Line View mode, where it is possible to monitor the status of the relay in real-time. Convert event data to COMTRADE files if needed for subsequent analysis Figure 3: Typical Oscillography View in ProView Relay Replay To evaluate the effect different settings would have on the relay, the Relay- Replay feature of the Edison Idea s ProView software allows the user to make any number of setting changes and replay an existing event using these new settings without the need for an actual relay or expensive test equipment. The operation of every aspect of the relay s performance can be observed: which elements pick-up what is the response time of those elements that do. This tool provides unprecedented what-if analysis capabilities. 3

IDEA Capacitor Bank Protection Relay COMMUNICATIONS Modbus RTU and DNP 3.0 (serial or TCP/IP) communication protocols are available. Customize communication maps, add or delete information, add control points, and even create new signals to be brought out through communications via various serial or Ethernet ports. See Table 1 Ordering Options for details on available communication options. HARDWARE DIMENSIONS 4 Figure 4: Edison Idea Relay Panel Cutout and Outline Dimensions in Inches (mm) 0.28 0.41 R: 0.14

TYPICAL DC WIRING DIAGRAM 2 Power Supply 1 ci1 3 4 52, Cap Breaker ci2 5 6 ci3 7 8 9 Trip 10 ss1 52a 11 12 co1 13 15 14 Relay Alarm co2 17 16 Close co3 52b 19 co4 18 TB1 DC positive DC negative 1 2 co7 Breaker Fail TB4 Figure 5: DC Wiring Diagram / Idea AVAILABLE CAPACITOR UNBALANCE PROTECTION APPLICATION OPTIONS In Va Vb Vc Rn In Va Vb Vc Figure 6: Single Wye, Neutral Current (3-phase overcurrent inputs not shown) Vn Va Vb Vc Va Vb Vc Cn Figure 7: Single Wye, Neutral Voltage (3-phase overcurrent inputs not shown) Vn 165-440-900 5

IDEA Capacitor Bank Protection Relay 6 Ia In Ia Figure 8: Double Wye, Neutral Current (3-phase overcurrent and voltage inputs not shown) Ia Figure 9: Double Wye, Neutral Voltage (3-phase overcurrent and voltage inputs not shown) Ia Vn In Vn In Va Vb Vc Figure 10: Double Wye, Neutral Voltage and Current (3-phase overcurrent inputs not shown)

Table 1 Ordering Options Construct Catalog Number from this table. Product 165-440-900 A B C D E F G H I Idea Enclosure PR6 D2 C44 Sample Catalog Number: PR6 D2 C44 E 1 5 1 0 S TYPE Edison Idea/IdeaPlus Relay PR6 Edison Idea Chassis D2 Scheme/ -900 neutral unbalance cap bank scheme C44 Inserts English E Language Portuguese P Spanish S Other O Power 48VDC Power Supply 4 125VDC/120VAC Power Supply 1 250VDC/240VAC Power Supply 2 24VDC Power Supply 3 Input 5 Amp CT Inputs, 67/120V PT Inputs 5 Ranges 1 Amp CT Inputs, 67/120V PT Inputs 1 Comm. RS485 1 Options Fiber serial 3 Ethernet Fiber Optic:Fiber Optic MTRJ/MTRJ 4 Ethernet Fiber Optic:Wire MTRJ/RJ45 5 Ethernet Wire:Wire RJ45/RJ45 6 Standard: None 7 Ethernet Single Mode Fiber LC/LC 8 Aux I/O Select 8 Contact Inputs and 8 Contact Outputs, all N.O 0 Select 8 Contact Inputs and 8 Contact Outputs, 1 NC, 7NO 1 Select 8 Contact Inputs and 8 Contact Outputs, 2 NC, 6NO 2 Select 8 Contact Inputs and 8 Contact Outputs, 3 NC, 5NO 3 Term. All Barrier S All Compression C Relay Accessories Description Scheme Catalog Number 19 rack mount panel adapter for Idea relay PR6ADRP 19 2-relay side-by-side mounting adapter for Idea relays PR6ADJK 6 foot (2m) front panel RS232 cable F500066001 Language Power Input Range CommOption Aux I/O TermBlk 7

IDEA Capacitor Bank Protection Relay Specifications Frequency Voltage Inputs Current Inputs Digital Inputs (Optically Isolated) Relay Outputs Solid-State Outputs 50/60 Hz Six voltage input channels; four used in the scheme 50 250 VAC continuous (phase-to-neutral) Burden < 0.1VA at 120V Primary DC Resistance 1,454Ω Error % < 0.3% over operating temperature Four current input channels I Nominal = 5A, I continuous = 15A, I 3sec = 150A, I 1sec = 300A Range of overcurrents settings 0.1 A to 90 A Step size 0.01 A Burden < 0.2VA at 5A Primary DC Resistance 3.4 mω Error % < 0.3% over operating temperature I Nominal = 1A, I continuous = 3.2A, I 3sec = 30 A, I 1sec = 100A Range of overcurrents settings 0.02 A to 18 A Step size 0.002 A Burden < 0.2VA at 1A Primary DC Resistance 52.1 mω Error % < 0.3% over operating temperature 9 150 VDC [24 VDC power supply] 36 150 VDC [48 VDC power supply] 90 300 VDC [120 VAC / 125 VDC power supply] 165 300 VDC [240 VAC / 250 VDC power supply] Nominal current draw of 2.5 ma, minimum operating time of 15 msec 240 Vac / 250 Vdc. Make: 30A for 0.2 seconds; Carry: 6A continuous. Break: 0.2A (L/R = 40 ms) Pickup time: <8ms; Dropout time: <5ms 240 Vac / 250 Vdc; Make: 30A for 0.2 seconds; Carry: 8A continuous. Break: 10A (L/R = 40 ms) Pickup time: <1ms; Dropout time: <15ms Power Supply 24 VDC ± 20% 48 VDC ± 20% 120 VAC / 125 VDC ± 30% 240 VAC / 250 VDC ± 20% Burden: 14W Local/Remote communications EIA-RS-232C: 1 ea. located on front and rear panel Baud Rates: Auto baud rate up to 115,200 bps IRIG-B: 1 located on rear panel Optional Comm. Daughterboards (available with ProView 4.0.1): RS-485 (DC isolated) Modbus 57,600 bps; DNP 38,400 bps Serial Fiber Optic (ST) Ethernet, Multi-Mode, Fiber Optic (MTRJ/MTRJ) Ethernet, Multi-Mode, Fiber Optic / Wire (MTRJ/RJ45) Ethernet, Multi-Mode, Wire (RJ45/RJ45) Ethernet, Single-Mode, Fiber Optic (LC/LC) 8

Front Panel Targets Front Panel Display Front Panel Keypad Dimensions Relay Weight Mounting Operating Temperature 23 Programmable LEDs 20 x 4 character LCD 165-440-900 8 fixed-function keys, 4 multi-function "soft" keys 8 programmable Hot-Keys Idea relay: 3 U high by 8.5 wide; 19 rack mount adapter plates and side by side mounting kits available 10 lbs Horizontal -40 F to 158 F (-40 C to 70 C) continuous Bump & Shock Test IEC 60255-21-2 (1988) Class 1 Cold Temperature Test IEC 60068-2-1 (1993) 16 hours at 40C Electrostatic Discharge EN 61000-4-2 (2001) Levels 1, 2, 3, and 4. High temperature Test Humidity Test IEC 60068-2-2 (1993) 16 hours at 70C IEC 60068-2-30 (1999) 25C to 55C, 95% Humidity, 2 cycles Impulse/Dielectric Withstand IEC 60255-5 (2000) Impulse Test: 5kV, 1.2 μs rise time, half wave 50 μs. Applied 3 impulses at each polarity. Dielectric: 3150 VDC for 1 minute. Insulation Resistance: Greater than 10 Gigaohms. Radio Frequency Interference Radiated: EN 61000-4-3 (2001) 20 MHz 1 Ghz, Idea 35 V/m. ANSI/IEEE C37.90.2 (1995) 35V/m from 20 MHz to 1 GHz Conducted: IEC 61000-4-6 (2001) 150 khz 80 MHz, 10 Vrms IEC 61000-4-16 (2001) 15 Hz 150 khz, 10 Vrms Surge Withstand Vibration Test IEC 60255-21-1 (1988) Class 1 ANSI/IEEE C37.90.1 (2002) 2.5 kv oscillatory, ± 4 kv fast transient Contact Rating ANSI/IEEE C37.90, Section 6.7 (1989) 30A for 0.2 seconds, 2000 operations, at 125 VDC, 250 VDC, and 240 VAC. Object Penetration IEC 60529 (2001-02) IP3X rating Specifications subject to change without notice. 9

IDEA Capacitor Bank Protection Relay 10

165-440-900 11

IDEA Capacitor Bank Protection Relay 2007 Cooper Power Systems, Inc., or its affiliates. ProView, IDEA Workbench, User Workbench, Relay-Replay, and Virtual Test Set are trademarks of Cooper Power Systems, Inc., or its affiliates. Edison is a registered trademark of Cooper Power Systems, Inc., or its affiliates. (Relay Replay United States Patent Number 5,878,375) Microsoft Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. 12