TC22/23/24/25 Capacitance level transmitter - electronic preamplifi er

Similar documents
MTU5. Warranty. Factory Test Certificate. Ultrasonic level transmitter. Technical Data. MTU5... Production and check date:...

METER Ultrasonic level transmitter

CAPACITIVE: CONTROL CLS2 CLS4 CLS5. Applications liquids / solids liquids / solids solids / granules

KTU5 ultrasonic level transmitter

METER. ultrasonic level transmitter. technical documentation EN Rev. P

FLOWMETER Ultrasonic flow transmitter

VLW90M Tank Inventory, Differential Level, Open Channel Flow, Pumps Control

Instruction Manual. T3110 T3110L T3110Ex

Resolver to Digital Expansion Board

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

USER MANUAL. WBV412U01 AC voltage transducer

SWING. Tank Inventory, Differential Level, Open Channel Flow, Pumps Control

CAPVEL-LP : User Manual & Datasheet Contact level transmitter based on capacitance measurement

Level transmitter TR3420 Instructions manual

Level-Lance Model 5400A

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

EX-RC1 Remote I/O Adapter

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

USER MANUAL. WBI412F41 AC current transducer

USER MANUAL. WBI414F21 AC current transducer

FLS M9.06. ph/orp MONITOR

8000 Series: Installation Supplement R2-1-12

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

MAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Installation, Operation & Maintenance Instructions

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

FA-2448 SIX POSITION Filter Wheel

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

VariTrans P Standard-Signal Isolators

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

FLOW MONITOR & TRANSMITTER

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

OPERATION MANUAL MODEL TT-LP

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

AEXX-349 SERIES REMOTE DISPLAYS

Intrinsically safe batch controller Batching Master 110i

Conveyor Belt Alignment Switches from IDEM

87421/22A Power Supply. Operating and Service Manual

SWING Ultrasonic Level & Flow Controller

AWP-24 Wave Height Gauge User's Guide

Remote Divert User Interface DI. Instruction Manual

User's Guide. Extech AM A AC Analog Clamp Meter

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

SCHMIDT Sensor interface PROFIBUS Instructions for use

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Operating Instructions VEGAMET 381

This document set is applicable to the following part number configurations:

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

User's Guide. Model High Precision Quad Output DC Power Supply

Operating Manual RISH DPM Hz

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

LCI User Manual mantracourt.com

Temperature Switches

Operating Instructions Differential Pressure Transducer PS27

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

DC425 NEMA 4X Analog Output Transducers

QAL50 Series Analog Line Sensor

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

ES-600 Ozone Controller Operation Manual

Model Number: DZ300-12EU

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

InCos-P Pressure sensor 20 Pa Pa

LPG STM 94442A User s Manual

20W Tungsten-Halogen Light Source. Operation Manual

BTU 4 & Sensors. Installation and Operation Manual

WS115 BREAKOUT ADAPTER USER MANUAL

V E1B Snap-in I/O Module

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Automated Tuner System Power Distribution Hub

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

V3 series Inductive sensors with AC/DC supply voltage

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

KBMG MULTI-SPEED BOARD

DEVAR Inc. Model d-rtti User Manual

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

Mini position indicator

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

Transcription:

TC22/23/24/25 Capacitance level transmitter - electronic preamplifi er technical documentation EN Rev. S

TC22 25 - contents CONTENTS 1-WARRANTY 2-PRODUCT 3-TECHNICAL FEATURES 4-DIMENSIONS 5-MECHANICAL INSTALLATION 6-ELECTRICAL CONNECTIONS 7-CALIBRATIONS 8-REMOTE VERSION 9-FACTORY TEST AND QUALITY CERTIFICATE page 3 page 4 page 5 page 6 page 7 page 8 page 10 page 15 page 16 Pag. 2 di 12 www.sgm-lektra.com

TC22 25 - warranty 1-WARRANTY Products supplied by SGM LEKTRA are guaranteed for a period of 12 (twelve) months from delivery date according to the conditions specifi ed in our sale conditions document. SGM LEKTRA can choose to repair or replace the Product. If the Product is repaired it will maintain the original term of guarantee, whereas if the Product is replaced it will have 12 (twelve) months of guarantee. The warranty will be null if the Client modifi es, repair or uses the Products for other purposes than the normal conditions foreseen by instructions or Contract. In no circumstances shall SGM LEKTRA be liable for direct, indirect or consequential or other loss or damage whether caused by negligence on the part of the company or its employees or otherwise howsoever arising out of defective goods. www.sgm-lektra.eu Pag. 3 di 12

TC22 25 - product 2-PRODUCT 3 1 2 2 4 1. Led indicators 2. Terminals for electrical connections 3. Programming buttons 2. Fixing system to the probe 1.2 IDENTIFICATION Each instrument has an adhesive identifi cation plate on which are the meter main data. The following picture describes the information and data on the identifi cation plate. 1 2 3 Mod. 400A072B - TC22 P.S. S.N. 24Vdc CCE091501066 1. Product code 2. Power supply 3. Serial number Pag. 4 di 12 www.sgm-lektra.com

TC22 25 - technical features 3-TECHNICAL FEATURES Housing material Nylon; metallized Nylon Mechanical fitting Bajonet (to be insert into IP66/67 enclosure) IP rating IP50 Electrical connection 1 x 6 pole plug-in connector Working temperature -30 +80 C Power supply TC22 24Vdc TC23 24 Vac 50Hz TC24 115 Vac 50Hz TC25 230 Vac 50Hz Measure range 30pF 10.000pF Consumption Max 2.5W (1.5W Vdc) Analog output 4 20 ma (max 500ohm) Serial output RS485 Termichal drift compensation by ref. internal capacitor Linearity ±0.5% Calibration two push-buttons, for self-acquisition Led display : run mode Fixed LED: calibration mode www.sgm-lektra.eu Pag. 5 di 12

TC22 25 - dimensions 4-DIMENSIONS 60 mm 51 mm 27 mm 120 mm Pag. 6 di 12 www.sgm-lektra.com

TC22 25 - mechanical installation 5-MECHANICAL INSTALLATION 5.1 SAFETY MEASURE - Installation must be only performed by qualifi ed personnel and in accordance with local governing regulations. - The equipment must be used only after having correctly transposed the instructions of this manual - The power supply and electrical connections plate data must always be respected - Improper device use would cause serious damage to people, to the product and connected equipment 5.2 INSTALLATION The TC22 25 insert must be lodge into the IP66/67 capacitancesensor head connection. Important to screw tight the cover of the head connection and the cable gland in order to grant the sensor IP66/67. Thanks to the bayonet fi xing-system, to insert or remove the TC22 25 from the head connection need to push and rotate. Rotate clock-wise to fi x into the head Rotate reverse-clock-wise to remove from the head. No screws or conventional mounting system required. Important! Fully tighten the cap and cable glands to prevent water infi ltration and ensure the IP66/67 protection. www.sgm-lektra.eu Pag. 7 di 12

TC22 25 - electrical connection 6-ELECTRICAL CONNECTION 6.1 CONNECTIONS The TC22 25 capacitive transmitter can be supplied in DC or AC voltage depending on the model as shown in the following images. The current consumption is less than 1,5W for Vdc power supply and 2,5W for Vac power supply. The TC22 25 capacitance trannsmitters are lodged into the sensor capacitance head connections; remove the cover unscrewing and opening the upper part, gain the access to two 6-pole plug-in connectors. Electrical connection must be made with a multi-wires round cable of proper diameter, otherwise the seal of the cable gland may be impaired. No special cable or coax-cable are requests for compact version, and no practice distance limits. For the Vdc power supply take in consideration that the negative of the power supply is electrically connected to the negative output current. For the Vac power supply versions, from the power supply and the output current there is a galvanically separation. 24Vdc + - P2 P1 + 4 20mA - Probe SCH A B RS485 TC22 24Vdc L N GND P2 P1 + 4 20mA - Probe SCH A B RS485 TC23 24Vac TC24 115Vac TC25 230Vac Pag. 8 di 12 www.sgm-lektra.com

TC22 25 - electrical connection 6.2 REMOTE ELECTRODES CONNECTIONS Connecting the coaxial cable for probes version with electronic separate from the electrode. Probe (red) SCH (yellow/green) 6.3 GROUNDING CONNECTION Always connect the electrode to vessel ground. For this purpose there is a terminal on the side of the housing or on the mechanical connection. This connection is also used to supply the ground reference potential as well as to drain off electrostatic charges. GND www.sgm-lektra.eu Pag. 9 di 12

TC22 25 - calibration 7-CALIBRATION 7.1 CALIBRATION The TC22 25 calibration can be made by means the P1 and P2 push-buttons in two different procedures: a) Full-Empty Calibration. b) High and Low-point Calibration. To calibrate, needs to lodge the TC22 25 into the head connection of the capacitance sensor installed into the vessel or tank in which needs the level measurement. Depends to the possibility to reach easily 0% and 100% level is possible to use: Full-Empty Calibration or, when 0% and 100% level can t be reached High and Low-point Calibration procedure can be used, see fi g.below. Important! The calibration can be done fi rst with empty and than with full (as the above procedure) or fi rst with full and than with empty as well. full 100% 20mA intermediate points calibration level 100% full high point high point low point 0% 4mA empty 20mA low point empty 0% 4mA Pag. 10 di 12 www.sgm-lektra.com

TC22 25 - calibration 7.2 EMPTY AND FULL 4 20mA CALIBRATION The TC22 25 transmitter can be calibrate in respectively at the level of 0% and 100% level, in order to memorise the relevant capacity electronically. 7.2.1 0% (4mA) calibration needs to have the level at the 0%. Press simultaneously P1 and P2, release them and verify that led will stay fi x lightened. Press two times P1. The measured capacity has been memorised and associated to 4mA output. Press simultaneously P1 and P2 again to switch in measure mode ( led fl ashing). Empty Calibration 0% 4mA Measure x 2 Measure Fixed LED Fixed LED www.sgm-lektra.eu Pag. 11 di 12

TC22 25 - calibration 7.2.2 100% (20mA) calibration needs to have the level at the 100%. Press simultaneously P1 and P2, release them and verify that led will stay fi x lightened. Press two times P1. The measured capacity has been memorised and associated to 20mA output. Press simultaneously P1 and P2 again to switch in measure mode ( led fl ashing). Full calibration 100% 20mA Measure Measure x 2 Fixed LED Fixed LED Pag. 12 di 12 www.sgm-lektra.com

TC22 25 - calibration 7.3 HIGH AND LOW POINT CALIBRATION 7.3.1 Low Point calibration If only a limitate level variation is possible, the calibration of the TC22-5 is still possible. Need to connect a current-meter on the TC22-5 output current and verify the present level point at which make the calibration. Supposely you are on the Low-point calibration, and the relevant level is 26%(8,16mA) than; Press simultaneously P1 and P2, release them and verify that led will stay fi x lightened, Open the calibration mode. Press two times P1. The measured capacity has been associated at the moment to 4mA output. Now, pushing few times the P2 key, increase the output current from 4mA to 8,16mA, (P1 decrease the value). Once the correct current-output is displayed in to the current meter; press simultaneously P1 and P2 again to Exit from calibration going in measure mode ( led fl ashing). Low Point calibration 4mA Measure x 2 Measure Fixed LED Fixed LED www.sgm-lektra.eu Pag. 13 di 12

TC22 25 - calibration 7.2.2 High Point calibration Increase the level of your product as much as possible, for instance up to 58%(13,28mA) than; Press simultaneously P1 and P2, release them and verify that led will stay fi x lightened, Open the calibration mode. Press two times P2. The measured capacity has been associated at the moment to 20mA output. Now, pushing few times the P1 key, decrease the output current from 20mA to 13,28mA, (P2 increase the value) ; press simultaneously P1 and P2 again to Exit from calibration going in measure mode ( led fl ashing). Important! The calibration can be done fi rst with low-point and than with high-point (as the above procedure) or fi rst with high-point and than with low-point as well. High Point calibration 20mA Measure Measure x 2 Fixed LED Fixed LED Pag. 14 di 12 www.sgm-lektra.com

TC22 25 - remote version 8-REMOTE VERSION WITH FIXING BASE The R and S versions of the CLTx capacitive probes have an aluminum base. It is used to fi x the housing and connect the coaxial cable from the electrode. To connect the coaxial cable, proceed as follows: A - Unscrew the four screws on the base bottom B - Rotate the housing to access the inside of the aluminum base C - Connect the red wire to the central connection point (electrode signal) and the yellow-green cable to the lateral connection point (cable shield) D - Tighten the 4 screws on the base bottom E - Tighten the cable gland F - Fix the housing red yellow/ green A B C D E F www.sgm-lektra.eu Pag. 15 di 12

Documentation subject to technical change with no prior warning 9-FACTORY TEST AND QUALITY CERTIFICATE In conformity to the company and check procedures I certify that the equipment: (electronic preamplifi er) (capacitive probe) is conform to the technical requirements on Technical Data and it is made in conformity to the procedure Quality Control Manager:... Production and check date:... SGM-LEKTRA S.r.l. Via Papa Giovanni XXIII, 49 20090 Rodano (MI) - ITALY tel: ++39 02 95328257 fax: ++39 02 95328321 e-mail: info@sgm-lektra.com web: sgm-lektra.com