DN-700C / DN-501C MIDI Command Guide

Similar documents
Specification. For. Serial Interface DN-T645/625

Specification. for. Serial Interface DN-C635

DV4001/DV6001/DV7001 VC6001. RS-232C Control Specification

[DP19] DN-500CD. Serial Command Protocol Guide

TASCAM SS-CDR250N/SS-R250N CONTROL I/O Terminals RS-232C/TELNET Protocol Specifications

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

4. CONTROL FEATURES RS-232C CONTROL. (2) Control command codes. (1) Interface Condition. (3) Status Request and Status Information codes ENGLISH

Planar Simplicity Series

C628 Enhanced JPEG Module. User Manual

Communications Protocol

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Industrial Serial Device Server

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam UDP411 BD Player

TRP-C37 User s Manual

JPEG2000 HDTV RECORDER

Generic RS232 protocol

Projector Control Command Reference Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

User Manual A08. User Manual

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

20 Channel MP3 Sound Board. User s Manual. Model: FN-BC20

Logosol Joystick Node LS-731

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam BDP100/300 BD Players

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC

Sender Receiver Sender

TRP-C37M User s Manual

1. Summary. 2. Module Application Instruction. 1.2.Features. 1.3.Application Specification Description

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

DataVU 5 - Interface Manual Modbus

TRP-C37M User s Manual

TASCAM HS-2/HS-20/HS-2000

imcu7100evb User s Guide

DataVU 5 - Interface Manual Modbus

WIZ140SR/WIZ145SR Datasheet

ALESIS M20. RS-422 Implementation

IO64 User's Manual. Rev C. Document

Starter Guide Version Sphinx Access Control System

MF1-RW-TTL-PCB Mhz Mifare ISO14443A reader/writer module with TTL interface CONTENT 1. MAIN FEATURES...,, PINNING INFORMATION...

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Reference Guide. Remote Control

TTL TO ETHERNET Module. MODEL No: TTL-Sereth1P VER 1.0

960H H.264 DVR Setup Guide

Ethernet Serial Server

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam Solo Movie 2.1 and 5.1

FEC-240G. Rev. Date

15693-RW-TTL-PCB1 CONTENT 1. MAIN FEATURES PINNING INFORMATION BAUD RATE SETTING COMMUNICATION PROTOCOL...5

B-100 / B-300 Series HDMatrix Switchers

1. Implemented CM11 protocol

DN120 DeviceNet Gateway User Manual

Technical Description

Application Note BDLxxxx RS232 SERIAL INTERFACE COMMUNICATION PROTOCOL (SICP V1.82)

Visual KeyMaker. Programming Software Instructions. Contents A B

HVR-1500 HVR-1500A. PROTOCOL MANUAL 1st Edition (Revised 8) DIGITAL VIDEOCASSETTE PLAYER DSR-60/60P DSR-1600/1600P DSR-1600A/1600AP

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

Standard H.264 DVR Setup Guide

User Manual. Multi-display Control Module Protocol MCS. dedicated KVM switch and rackmount screen technology

ALESIS M20. System Exclusive

FLAT WIDE DISPLAY FWD-50PX1. PROTOCOL MANUAL (USER CONTROL ONLY) 1st Edition

WiFi to RS-422/485 adapter user manual

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A

AVE DR16X / AVE DR8X Quick Installation Guide

Cable Pinouts. SRP I/O Module

Russound Controllers. RNET Protocol & Specifications RS-232 Communication. Document version

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:

USB-SD MP3 Module Manual

FN-BC04 MP3 Sound Module with 10W Amplifier. User s Manual

Application Note: Using Modbus With the Conext CL Series. Important Safety Instructions

C1182 Video Compression Module User Manual. Release Note: 1 st Release : Aug 01, 2012

Winsonic MODBUS Remote IO user manual Rev. 1.0

Appendix) Specifications of Monitor & Control Rev. 4.0 July 13, 2016

DGH A3000 Configuration Guide For use with DGH Modules

e-net TCP/IP Converters

Name: Serial MP3 Player A manual

T-7 FINGERPRINT TERMINAL. HARDWARE USER'S MANUAL Rev 1.1

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

HDTVMT0404VL1 User Manual

Tel: Fax:

Locus Engineering Inc

C6820 Enhanced JPEG Module. User Manual V2.0. Release Note: 1. Feb 8, 2007 official released v Nov 16, 2007 released V2.0

The RS-485 user manual for B800 series communication

VC-C4 COMMUNICATION CAMERA PROGRAMMER'S MANUAL

TASCAM HD-R1. Serial Control port RS-232C Protocol Specification Document

HRM-0800 Instruction Manual

CDN36X Series DeviceNet Gateway User Manual

C-MAX CME8000-BUS. Module Layout CME8000-BUS-LP02 RS232. Industrial Module with CME8000 receiver IC. Short Description

Modbus Gateway User's Manual ADM-5850G

SSE232-LE Serial Server- User s Manual

KYTronics Corp.,Ltd KYT-22XX SPECIFICATIONS B 1 OF kytronics.co.kr. 3 rd Floor, A-Dong, Twin Town-Bldg,

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0

Hardware technical specifications Front Face of the 512 / 1024 channels interfaces LED 7-segments display operation:...

Room Control Module (2000i-RCM) Interface Command Structure. for the

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

B-520-MTRX-230 HDBaseT Matrix Switchers

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features

USR-TCP User Manual

Lite H.264 DVR Setup Guide

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

Transcription:

DN-700C / DN-501C September 10 th, 2014 Ver.1.00 1

Contents 1. General... 3 2. Specification... 4 2-1. RS-232C Control... 4 2-2. IP Control (Ethernet) * DN-700C only... 6 3. Communication Protocol... 7 4. Command List... 8 4-1. Playback operation... 8 4-2. Device operation... 11 4-3. File operation... 12 4-4. Playback setting... 13 4-5. Device setting... 17 4-6. Playback status... 20 4-7. Device status... 24 4-8. Get list... 25 2

1. General Note: In this document, the controlled equipment is called the device (our product) and the controlling equipment is called the host. The Serial Remote control function can be used when the host machine, like a PC, is connected to the device. The host controls the device by sending Control commands and detects the device's status by sending Status Request commands. The device and host can be connected in one of two ways: RS-232C and IP (Ethernet). Three main features: 1. Device control from the host 2. Device status detection via Status Request commands from the host 3. Device status changes are sent automatically to the host 3

2. Specification 2-1. RS-232C Control The host can control the device when they are connected with a RS-232C straight cable. Connect the cable to the device's 9-pin D-sub connector as shown in the following diagram. Transmission type: Asynchronous / full duplex Connector type: 9-pin D-sub (straight) Transfer rate: 9,600 / 38,400 bps, selectable (via Serial Bit Rate in the System Setting menu) Clock accuracy: < +2.0% Data length: 8 bits Parity: None Start bit: 1 bit Stop bit: 1 bit Flow Control: None Maximum data length: 93 bytes 4

Pin Assignments Pin No. Signal Name I/O 1 GND - 2 TxD Transfer 3 RxD Receiver 4 NC - 5 S.GND - 6 NC - 7 NC - 8 NC - 9 NC - 5

2-2. IP Control (Ethernet) * DN-700C only The host can control the device when they are connected with an Ethernet cable. Connect the cable to the device's RJ-45 connector as shown in the following diagram. (10BASE-T / 100BASE-TX) IP Control Connection Transmission type: Full duplex Transfer speed: 10 Mbps / 100 Mbps TCP port number: 23 (telnet) Maximum data length: 93 bytes 6

3. Communication Protocol Commands are sent using command packets between the start byte and end byte. 0x F0004003 (Start Byte) Command Packet 0xF7 (End byte) This is the format of command packet: Format Total Command Packet Remain Command Packet Command Parameter Pack Length Parameter Pack Checksum (0x11) (1 byte) (1 byte) (2 bytes) (1 byte) (0-80 bytes) (2 bytes) Item Format Total Command Packet Remarks 0x11 Fixed. This is used when sending a command whose parameter length is more than 80 bytes. When the parameter length is 80 bytes or less, the Total Command Packet is 1. Remain Command Packet This is used when sending a command whose parameter length is more than 80 bytes. When the parameter length is 80 bytes or less, the Total Command Packet is 0. Command Parameter Pack Length Parameter Pack Checksum This is structured by the Category code and Command. The length is 2 bytes. The length of the Parameter Pack. The maximum length is 80 bytes. The command parameter. The sum from Format to Parameter Pack. The MSB 4-bit and LSB 4-bit are then translated into ASCII code. Example: In ASCII, 3 is 0x33 and F is 0x46. When the checksum is 0x3F, this is translated into 0x33, 0x46. 7

4. Command List 4-1. Playback operation Command Category Code Command Example Example Command Code * Red points are variable Remark [STOP] 0 1 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x01,0x00,0x31,0x33,0xF7 [PLAY] 0 2 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x02,0x00,0x31,0x34,0xF7 [PAUSE] 0 3 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x03,0x00,0x31,0x35,0xF7 [CUE] 0 4 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x04,0x00,0x31,0x36,0xF7 [CUE TRK] 0 5 Move to track #1 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x05,0x04,0x30,0x30,0x30,0x31,0x44,0x43,0xF7 [CUE TIME 0 6 Move to 000:05:67 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x06,0x09,0x30,0x30,0x30,0x3a,0x30,0x35,0x3b, * 2 000:05:67] in current track 0x36,0x37,0x46,0x38,0xF7 [FRAME FWD] 0 7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x07,0x00,0x31,0x39,0xF7 [FRAME REV] 0 8 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x08,0x00,0x31,0x41,0xF7 [SEARCH SS1 FWD] 0 10 Speed 1 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x0A,0x00,0x31,0x43,0xF7 [SEARCH SS1 REV] 0 11 Speed 1 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x0B,0x00,0x31,0x44,0xF7 [SEARCH SS2 FWD] 0 12 Speed 2 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x0C,0x00,0x31,0x45,0xF7 [SEARCH SS2 REV] 0 13 Speed 2 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x0D,0x00,0x31,0x46,0xF7 [SEARCH SS3 FWD] 0 14 Speed 3 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x0E,0x00,0x32,0x30,0xF7 [SEARCH SS3 REV] 0 15 Speed 3 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x0F,0x00,0x32,0x31,0xF7 [SEARCH SS4 FWD] 0 16 Speed 4 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x10,0x00,0x32,0x32,0xF7 [SEARCH SS4 REV] 0 17 Speed 4 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x11,0x00,0x32,0x33,0xF7 [SEARCH SS5 FWD] 0 18 Speed 5 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x12,0x00,0x32,0x34,0xF7 [SEARCH SS5 REV] 0 19 Speed 5 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x13,0x00,0x32,0x35,0xF7 [TRACK FWD] 0 20 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x14,0x00,0x32,0x36,0xF7 [TRACK REV] 0 21 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x15,0x00,0x32,0x37,0xF7 The parameter and checksum (written in red) are variable. The parameter should be 0001 to 2000 in ASCII. * 2 The parameter and checksum (written in red) are variable. The parameter should be 000:00;00 to 999:59;74 in ASCII. 8

Command Category Code Command Example Example Command Code * Red points are variable Remark [HOT START] 0 22 Start HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x01,0x32,0x41,0xF7 Start HOT #02 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x02,0x32,0x42,0xF7 Start HOT #03 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x03,0x32,0x43,0xF7 Start HOT #04 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x04,0x32,0x44,0xF7 Start HOT #05 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x05,0x32,0x45,0xF7 Start HOT #06 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x06,0x32,0x46,0xF7 Start HOT #07 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x07,0x33,0x30,0xF7 Start HOT #08 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x08,0x33,0x31,0xF7 Start HOT #09 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x09,0x33,0x32,0xF7 Start HOT #10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x0A,0x33,0x33,0xF7 Start HOT #11 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x0B,0x33,0x34,0xF7 Start HOT #12 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x0C,0x33,0x35,0xF7 Start HOT #13 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x0D,0x33,0x36,0xF7 Start HOT #14 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x0E,0x33,0x37,0xF7 Start HOT #15 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x0F,0x33,0x38,0xF7 Start HOT #16 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x10,0x33,0x39,0xF7 Start HOT #17 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x11,0x33,0x41,0xF7 Start HOT #18 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x12,0x33,0x42,0xF7 Start HOT #19 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x13,0x33,0x43,0xF7 Start HOT #20 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x16,0x01,0x14,0x33,0x44,0xF7 9

Command Category Code Command Example Example Command Code * Red points are variable Remark [HOT CUE] 0 23 Cue up HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x01,0x32,0x42,0xF7 Cue up HOT #02 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x02,0x32,0x43,0xF7 Cue up HOT #03 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x03,0x32,0x44,0xF7 Cue up HOT #04 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x04,0x32,0x45,0xF7 Cue up HOT #05 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x05,0x32,0x46,0xF7 Cue up HOT #06 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x06,0x33,0x30,0xF7 Cue up HOT #07 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x07,0x33,0x31,0xF7 Cue up HOT #08 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x08,0x33,0x32,0xF7 Cue up HOT #09 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x09,0x33,0x33,0xF7 Cue up HOT #10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x0A,0x33,0x34,0xF7 Cue up HOT #11 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x0B,0x33,0x35,0xF7 Cue up HOT #12 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x0C,0x33,0x36,0xF7 Cue up HOT #13 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x0D,0x33,0x37,0xF7 Cue up HOT #14 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x0E,0x33,0x38,0xF7 Cue up HOT #15 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x0F,0x33,0x39,0xF7 Cue up HOT #16 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x10,0x33,0x41,0xF7 Cue up HOT #17 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x11,0x33,0x42,0xF7 Cue up HOT #18 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x12,0x33,0x43,0xF7 Cue up HOT #19 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x13,0x33,0x44,0xF7 Cue up HOT #20 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x17,0x01,0x14,0x33,0x45,0xF7 [SKIP BACK] 0 24 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x18,0x00,0x32,0x41,0xF7 [FRAME ON] 0 25 Frame On 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x19,0x01,0x01,0x32,0x44,0xF7 Frame Off 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x19,0x01,0x00,0x32,0x43,0xF7 [END MONITOR] 0 26 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x00,0x1A,0x00,0x32,0x43,0xF7 10

4-2. Device operation Command Category Code Command Example Example Command Code * Red points are variable Remark [POWER ON] 1 1 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x01,0x00,0x31,0x34,0xF7 [POWER STANDBY] 1 2 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x02,0x00,0x31,0x35,0xF7 [RETRACT] 1 3 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x03,0x00,0x31,0x36,0xF7 [EJECT] 1 4 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x04,0x00,0x31,0x37,0xF7 [UNBAL VOL UP 10] 1 5 Volume up 0.1 db 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x05,0x02,0x30,0x31,0x37,0x42,0xF7 Volume up 1.0 db 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x05,0x02,0x30,0x41,0x38,0x42,0xF7 [UNBAL VOL DN 10] 1 6 Volume down 0.1 db 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x06,0x02,0x30,0x31,0x37,0x43,0xF7 [UNBAL VOL -123] 1 7 Volume -12.3dB Volume down 1.0 db 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x06,0x02,0x30,0x41,0x38,0x43,0xF7 Volume +10.0dB 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x07,0x04,0x01,0x31,0x32,0x33,0x42, 0x35,0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x07,0x04,0x00,0x31,0x30,0x30,0x41, 0x46,0xF7 [ENTER] 1 8 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x08,0x00,0x31,0x42,0xF7 * 2 [ESC] 1 9 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x09,0x00,0x31,0x43,0xF7 [ABORT] 1 10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x0A,0x00,0x31,0x44,0xF7 [ARROW D] 1 11 Arrow down 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x0B,0x00,0x31,0x45,0xF7 [ARROW U] 1 12 Arrow up 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x0C,0x00,0x31,0x46,0xF7 [ARROW R] 1 13 Arrow right 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x0D,0x00,0x32,0x30,0xF7 [ARROW L] 1 14 Arrow left 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x01,0x0E,0x00,0x32,0x31,0xF7 The parameter and checksum (written in red) are variable. The parameter should be 00 to FF (hexadecimal) in ASCII (e.g., 1.0dB = 0A, 1.6dB = 10 ). * 2 The parameter and checksum (written in red) are variable. The parameter should be as below: Byte 1: 0:Plus / 1:Minus Byte2 to Byte5: 10 times the value of the volume in ASCII (+1.23 is 0x00,0x31,0x32,0x33) 11

4-3. File operation Command Category Code Command Example Example Command Code * Red points are variable Remark [HOT LOAD] 3 3 Load Hot List from USB: DN-700C.PPL 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x03,0x03,0x22,0x35,0x35,0x35, 0x33,0x34,0x32,0x33,0x41,0x35,0x43,0x35,0x43,0x34,0x34,0x34,0x45, 0x32,0x44,0x33,0x37,0x33,0x30,0x33,0x30,0x34,0x33,0x32,0x45,0x35, 0x30,0x35,0x30,0x34,0x43,0x37,0x43,0xF7 Load Hot List from USB: DN-700C.ppl 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x03,0x03,0x22,0x35,0x35,0x35, 0x33,0x34,0x32,0x33,0x41,0x35,0x43,0x35,0x43,0x34,0x34,0x34,0x45, 0x32,0x44,0x33,0x37,0x33,0x30,0x33,0x30,0x34,0x33,0x32,0x45,0x37, 0x30,0x37,0x30,0x36,0x43,0x38,0x32,0xF7 [HOT SAVE] 3 4 Save Hot List to USB: DN-700CS.PPL 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x03,0x04,0x24,0x35,0x35,0x35, 0x33,0x34,0x32,0x33,0x41,0x35,0x43,0x35,0x43,0x34,0x34,0x34,0x45, 0x32,0x44,0x33,0x37,0x33,0x30,0x33,0x30,0x34,0x33,0x35,0x33,0x32, 0x45,0x35,0x30,0x35,0x30,0x34,0x43,0x45,0x37,0xF7 [PRG LOAD] 3 5 Load Program List from USB: DN-700C.M3U 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x03,0x05,0x22,0x35,0x35,0x35, 0x33,0x34,0x32,0x33,0x41,0x35,0x43,0x35,0x43,0x34,0x34,0x34,0x45, 0x32,0x44,0x33,0x37,0x33,0x30,0x33,0x30,0x34,0x33,0x32,0x45,0x34, 0x44,0x33,0x33,0x35,0x35,0x38,0x35,0xF7 [PRG SAVE] 3 6 Save Program List to USB: DN-700CS.M3U 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x03,0x06,0x24,0x35,0x35,0x35, 0x33,0x34,0x32,0x33,0x41,0x35,0x43,0x35,0x43,0x34,0x34,0x34,0x45, 0x32,0x44,0x33,0x37,0x33,0x30,0x33,0x30,0x34,0x33,0x35,0x33,0x32, 0x45,0x34,0x44,0x33,0x33,0x35,0x35,0x46,0x30,0xF7 Save Program List to USB: DN-70CS.M3U The parameter and checksum (written in red) are variable. The file name is specified as below: The separator is " (0x5C". The media name is CDA:, CDD:, USB:, or NETxxx:. 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x03,0x06,0x22,0x35,0x35,0x35, 0x33,0x34,0x32,0x33,0x41,0x35,0x43,0x35,0x43,0x34,0x34,0x34,0x45, 0x32,0x44,0x33,0x37,0x33,0x30,0x34,0x33,0x35,0x33,0x32,0x45,0x34, 0x44,0x33,0x33,0x35,0x35,0x38,0x42,0xF7 The folder name ends with " ". The root directory is specified by. The upper folder is specified by... (Example of the file path:i USB: FOLDER1 TRACK.mp3.) All characters are transferred to 2 bytes. (Example: A is 0x41 in ASCII. This MSB is 4 (0x34), and this LSB is 1 (0x31). Therefore, the A is transferred to 0x34,0x31.) 12

4-4. Playback setting Command Category Code Command Example Example Command Code * Red points are variable Remark [HOT SET] 5 1 Set current track to HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x01,0x31,0x41,0xF7 Set current track to HOT #02 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x02,0x31,0x42,0xF7 Set current track to HOT #03 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x03,0x31,0x43,0xF7 Set current track to HOT #04 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x04,0x31,0x44,0xF7 Set current track to HOT #05 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x05,0x31,0x45,0xF7 Set current track to HOT #06 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x06,0x31,0x46,0xF7 Set current track to HOT #07 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x07,0x32,0x30,0xF7 Set current track to HOT #08 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x08,0x32,0x31,0xF7 Set current track to HOT #09 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x09,0x32,0x32,0xF7 Set current track to HOT #10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x0A,0x32,0x33,0xF7 Set current track to HOT #11 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x0B,0x32,0x34,0xF7 Set current track to HOT #12 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x0C,0x32,0x35,0xF7 Set current track to HOT #13 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x0D,0x32,0x36,0xF7 Set current track to HOT #14 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x0E,0x32,0x37,0xF7 Set current track to HOT #15 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x0F,0x32,0x38,0xF7 Set current track to HOT #16 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x10,0x32,0x39,0xF7 Set current track to HOT #17 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x11,0x32,0x41,0xF7 Set current track to HOT #18 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x12,0x32,0x42,0xF7 Set current track to HOT #19 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x13,0x32,0x43,0xF7 Set current track to HOT #20 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x01,0x01,0x14,0x32,0x44,0xF7 13

Command Category Code Command Example Example Command Code * Red points are variable Remark [HOT SET] 5 2 Set track #0010 to HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x02,0x05,0x01,0x30,0x30,0x31,0x30,0 x45,0x30,0xf7 Set track #0009 to HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x02,0x05,0x01,0x30,0x30,0x30,0x39,0 x45,0x38,0xf7 Set track #0008 to HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x02,0x05,0x01,0x30,0x30,0x30,0x38,0 x45,0x37,0xf7 [HOT RMV] 5 3 Remove HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x01,0x31,0x43,0xF7 Remove HOT #02 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x02,0x31,0x44,0xF7 Remove HOT #03 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x03,0x31,0x45,0xF7 Remove HOT #04 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x04,0x31,0x46,0xF7 Remove HOT #05 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x05,0x32,0x30,0xF7 Remove HOT #06 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x06,0x32,0x31,0xF7 Remove HOT #07 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x07,0x32,0x32,0xF7 Remove HOT #08 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x08,0x32,0x33,0xF7 Remove HOT #09 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x09,0x32,0x34,0xF7 Remove HOT #10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x0A,0x32,0x35,0xF7 Remove HOT #11 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x0B,0x32,0x36,0xF7 Remove HOT #12 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x0C,0x32,0x37,0xF7 Remove HOT #13 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x0D,0x32,0x38,0xF7 Remove HOT #14 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x0E,0x32,0x39,0xF7 Remove HOT #15 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x0F,0x32,0x41,0xF7 Remove HOT #16 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x10,0x32,0x42,0xF7 Remove HOT #17 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x11,0x32,0x43,0xF7 Remove HOT #18 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x12,0x32,0x44,0xF7 Remove HOT #19 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x13,0x32,0x45,0xF7 Remove HOT #20 [HOT IN ] 5 7 Set 000:01:23 to HOT #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x03,0x01,0x14,0x32,0x46,0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x07,0x0A,0x01,0x30,0x30,0x30,0x3a, 0x30,0x31,0x3b,0x32,0x33,0x46,0x34,0xF7 The parameter and checksum (written in red) are variable. The first byte is the hot list number (hexadecimal). The second byte to fifth byte is the track number ( 0000 to 2000 in ASCII). * 2 The parameter and checksum (written in red) are variable. The first byte is the hot list number (hexadecimal). The time information after that is in ASCII ( 000:00;00 to 999:59;74 ). * 2 14

Command Category Code [PRG INS ] 5 11 [PRG INS] 5 12 [PRG RMV] 5 13 [SET CUR FDR] 5 17 Command Example Example Command Code * Red points are variable Remark Insert current track to 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x0B,0x04,0x30,0x30,0x30,0x31,0x45,0x37,0xF7 program #0001 Insert track #1 to 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x0C,0x08,0x30,0x30,0x30,0x31,0x30,0x30,0x30,0x31, Program #0001 0x41,0x44,0xF7 * 2 Remove program #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x0D,0x04,0x30,0x30,0x30,0x31,0x45,0x39,0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x11,0x1C,0x35,0x35,0x35,0x33,0x34,0x32,0x33,0x41, Set Current folder 0x35,0x43,0x35,0x43,0x34,0x44,0x35,0x30,0x34,0x37,0x34,0x43,0x34,0x31,0x34,0x45,0x34,0x37, USB: MPGLANG1 0x33,0x31,0x34,0x43,0xF7 * 3 [SET CUR FDR FWD] 5 18 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x12,0x00,0x32,0x39,0xF7 [SET CUR FDR REV] 5 19 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x13,0x00,0x32,0x41,0xF7 [SET CUR FIL] 5 20 0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x14,0x04,0x30,0x30,0x30,0x31,0x46,0x30,0xF7 [PITCH SW XXX] 5 21 Pitch On 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x15,0x01,0x01,0x32,0x45,0xF7 Pitch Off 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x15,0x01,0x00,0x32,0x44,0xF7 [PITCH VAL ] 5 22 Pitch +12.3% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x16,0x06,0x00,0x30,0x31,0x32,0x33,0x30,0x32,0x39, 0xF7 * 4 Pitch -12.3% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x16,0x06,0x01,0x30,0x31,0x32,0x33,0x30,0x32,0x41, 0xF7 Pitch 0.0% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x16,0x06,0x00,0x30,0x30,0x30,0x30,0x30,0x32,0x33, 0xF7 [KEY SW] 5 25 Master Key On 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x19,0x01,0x01,0x33,0x32,0xF7 Master Key Off 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x19,0x01,0x00,0x33,0x31,0xF7 [PITCH UP LOW] 5 27 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x1B,0x00,0x33,0x32,0xF7 [PITCH UP MID] 5 28 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x1C,0x00,0x33,0x33,0xF7 [PITCH UP HI] 5 29 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x1D,0x00,0x33,0x34,0xF7 [PITCH DN LOW] 5 30 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x1E,0x00,0x33,0x35,0xF7 [PITCH DN MID] 5 31 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x1F,0x00,0x33,0x36,0xF7 [PITCH DN HI] 5 32 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x20,0x00,0x33,0x37,0xF7 The parameter and checksum (written in red) are variable. The first 4 bytes are the insert position ( 0000 to 0099 in ASCII). * 2 The parameter and checksum (written in red) are variable. The first 4 bytes are the insert position ( 0000 to 0099 in ASCII). The file number ( 0000 to 2000 in ASCII) follows it. * 3 The parameter and checksum (written in red) are variable. The file name format is referred to File Operation. * 4 The parameter and checksum (written in red) are variable. The parameter should be as below: Byte 1: 0:Plus / 1:Minus Byte 2 to Byte 5: 10 times the value of the pitch in ASCII (e.g., "+1.23" is "0x00,0x31,0x32,0x33"). 15

Command Category Code Command Example Example Command Code * Red points are variable Remark [SET AB ] 5 33 Set AB loop A point = 000:01;00 B point = 000:02;00 [SET CUR MEDIA XXX] 5 34 USB Set AB loop A point = 000:01;00 B point = 000:05;00 CD ipad Net 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x21,0x12,0x30,0x30,0x30,0x3A,0x30,0x31, 0x3B,0x30,0x30,0x30,0x30,0x30,0x3A,0x30,0x32,0x3B,0x30,0x30,0x44,0x37,0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x21,0x12,0x30,0x30,0x30,0x3A,0x30,0x31, 0x3B,0x30,0x30,0x30,0x30,0x30,0x3A,0x30,0x35,0x3B,0x30,0x30,0x44,0x41,0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x22,0x04,0x30,0x30,0x30,0x30,0x46,0x44, 0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x22,0x04,0x30,0x30,0x30,0x31,0x46,0x45, 0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x22,0x04,0x30,0x30,0x30,0x32,0x46,0x46, 0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x05,0x22,0x04,0x30,0x30,0x30,0x33,0x30,0x30, 0xF7 The parameter and checksum (written in red) are variable. The first 9 bytes are the A point time information in ASCII ( 000:00;00 to 999:59;74 ). The B point time information follows it with the same format. 16

4-5. Device setting Command Category Code Command Example Example Command Code * Red points are variable Remark [DIMMER XXX] 7 1 Dimmer 100% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x01,0x01,0x01,0x31,0x43,0xF7 Dimmer 75% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x01,0x01,0x02,0x31,0x44,0xF7 Dimmer 50% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x01,0x01,0x03,0x31,0x45,0xF7 Dimmer 25% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x01,0x01,0x04,0x31,0x46,0xF7 Dimmer 0% 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x01,0x01,0x05,0x32,0x30,0xF7 [LOCK XXX] 7 2 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x02,0x01,0x01,0x31,0x44,0xF7 [PRESET X: Y] 7 3 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x03,0x06,0x30,0x30,0x30,0x30,0x30,0x30,0x34, Shift Mde= LOCK 0x32,0xF7 [PRESET ALL CHG ] 7 4 (All 1) 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x04,0x30,0x30,0x31,0x30,0x31,0x30,0x31,0x30, 0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31, 0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30, 0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x36,0x35,0xF7 [PRESET DEFAULT 7 5 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x05,0x00,0x31,0x45,0xF7 [PRESET LOAD] 7 6 File name = default 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x06,0x00,0x31,0x46,0xF7 [PRESET SAVE] 7 7 File name = default 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x07,0x00,0x32,0x30,0xF7 7 8 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x08,0x0C,0x30,0x30,0x30,0x35,0x43,0x44,0x31 [SET MAC ADDR] 00-05-CD-12-00-70,0x32,0x30,0x30,0x37,0x30,0x41,0x33,0xF7 [GET MAC ADDR] 7 9 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x09,0x00,0x32,0x32,0xF7 [SYSCFG X Y] 7 10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x0A,0x06,0x30,0x30,0x30,0x30,0x30,0x30,0x34, System config 0:0 0x39,0xF7 [SYSCFG ALL CHG] 7 11 (All 1) 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x0B,0x22,0x30,0x31,0x30,0x31,0x30,0x31,0x30, 0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x31,0x30,0x30,0x30,0x30,0x30,0x30, 0x30,0x30,0x30,0x30,0x30,0x30,0x30,0x30,0x30,0x30,0x41,0x46,0xF7 [SYSCFG DEFAULT] 7 12 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x07,0x0C,0x00,0x32,0x35,0xF7 * 2 * 3 * 4 The parameter and checksum (written in red) are variable. The first 2 bytes are Parameter 1 ( 00 to 27 in ASCII). Parameter 2 follows ( 0000 to 001D in ASCII). Parameter 1 and 2 are specified in the following table. * 2 The parameter and checksum (written in red) are variable. Parameter 2 is stored each in 2 bytes. * 3 The parameter and checksum (written in red) are variable. The Mac address is specified 8 bytes ASCII strings * 4 The parameter and checksum (written in red) are variable. The first 2 bytes is the SYSCFG index num. (It is 00 to 08 in ASCII). The value ( 0000 to 0004 in ASCII) follows it. * 5 The parameter and checksum (written in red) are variable. The parameter 2 is stored each in 2 bytes. 17

Parameter 1 Item Parameter 2 0 1 2 3 4 5 6 7 0 Shift Mode Lock Momentary 1 Power On Stop Resume Play Play First 2 Play Range All Folder 3 Play Mode Single Contnuous 4 Random Off On 5 Program Off On 6 Finish Mode Stop Next Recue 7 Repeat Off On 8 Auto Cue Off -48dB -42dB -36dB 9 Skip Back 0.5sec to 60sec (0.5sec step) 0:0.5sec~29:60sec 10 Search Mode Normal Silent 11 Auto Fade In Off 0.5sec 1.0sec 3.0sec 12 Auto Fade Out Off 0.5sec 1.0sec 3.0sec 13 Start Delay Off 100msec 200msec 300msec 14 End Of Message Off 0sec 5sec 10sec 15sec 20sec 30sec 60sec 15 Next Trk Reserve Off On 16 Master Key Off On 17 Dimmer Off On 18 Display Dimmer 100% 75% 50% 25% 0% 19 LED Dimmer 100% 75% 50% 25% 20 Screen Saver Off On 21 Remain Time Mode Track Total 22 Fader Start Play Play-Pause Play-Next Play&Lock Play&Lock-Pause Play&Lock-Next 23 Para Rem Mode HotStart HotCue 18

Parameter1 Item Parameter2 0 1 2 3 4 0 Mono Off On 1 Volume Output Fixed(0dB) Variable 2 Output Rate Auto 44.1k 48k 3 Auto Sleep Off 30sec 10min 20min 30min 4 IR Remote Off On 5 Ref(XLR/RCA) +24dBu/+10dBV +20dBu/+6dBV +18dBu/+4dBV +6dBV/+6dBV 6 Display Contrast 1 2 3 4 5 7 Serial Bit Rate 9600 38400 8 Serial Protocol MIDI RC 19

4-6. Playback status Command Category Code Command Example Example Command Code * Red points are variable Remark [GET TRP STAT] 9 1 Get transport status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x01,0x00,0x31,0x43,0xF7 [GET CUR FDR] 9 2 Get current folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x02,0x00,0x31,0x44,0xF7 [GET ELP TIME] 9 3 Get elapse time 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x03,0x00,0x31,0x45,0xF7 [GET REM TIME] 9 4 Get remain time 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x04,0x00,0x31,0x46,0xF7 [GET CUR FILE] 9 5 Get current file 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x05,0x00,0x32,0x30,0xF7 [GET CUR TRK] 9 6 Get Current Track number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x06,0x00,0x32,0x31,0xF7 [GET CUR IDX] 9 7 Get current index number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x07,0x00,0x32,0x32,0xF7 [GET CUR SIZE] 9 8 Get current file size 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x08,0x00,0x32,0x33,0xF7 [GET CUR LEN] 9 9 Get current total time 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x09,0x00,0x32,0x34,0xF7 [GET CUR TITL] 9 10 Get title name 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x0A,0x00,0x32,0x35,0xF7 [GET CUR ART] 9 11 Get artist name 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x0B,0x00,0x32,0x36,0xF7 [GET CUR ALBM] 9 12 Get album name 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x0C,0x00,0x32,0x37,0xF7 [GET CUR CH] 9 13 Get channel number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x0D,0x00,0x32,0x38,0xF7 [GET CUR FMT] 9 14 Get file format 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x0E,0x00,0x32,0x39,0xF7 [GET CUR SMP] 9 15 Get sample rate 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x0F,0x00,0x32,0x41,0xF7 [GET TAT TTL] 9 16 Get total track number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x10,0x00,0x32,0x42,0xF7 [GET TAT FIL] 9 17 Get track file name 0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x11,0x04,0x30,0x30,0x30,0x31,0x46,0x31,0xF7 [GET CUE FILE] 9 18 Get current file name 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x12,0x00,0x32,0x44,0xF7 [GET CUE TRK] 9 19 Get current track number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x13,0x00,0x32,0x45,0xF7 [GET CUE TIME] 9 20 Get cue time 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x14,0x00,0x32,0x46,0xF7 [GET HOT NO] 9 21 Get Hot Number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x15,0x00,0x33,0x30,0xF7 [GET HOT FILE] 9 22 Get file name of Hot start 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x16,0x00,0x33,0x31,0xF7 The parameter and checksum (written in red) are variable. The first 4 bytes are the file number ( 0000 to 2000 in ASCII). 20

Command Category Code Command Example Example Command Code * Red points are variable Remark [GET HOT FILE XX] 9 23 Get file name of Hot list #01 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x01,0x33,0x34,0xF7 Get file name of Hot list #02 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x02,0x33,0x35,0xF7 Get file name of Hot list #03 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x03,0x33,0x36,0xF7 Get file name of Hot list #04 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x04,0x33,0x37,0xF7 Get file name of Hot list #05 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x05,0x33,0x38,0xF7 Get file name of Hot list #06 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x06,0x33,0x39,0xF7 Get file name of Hot list #07 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x07,0x33,0x41,0xF7 Get file name of Hot list #08 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x08,0x33,0x42,0xF7 Get file name of Hot list #09 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x09,0x33,0x43,0xF7 Get file name of Hot list #10 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x0A,0x33,0x44,0xF7 Get file name of Hot list #11 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x0B,0x33,0x45,0xF7 Get file name of Hot list #12 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x0C,0x33,0x46,0xF7 Get file name of Hot list #13 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x0D,0x34,0x30,0xF7 Get file name of Hot list #14 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x0E,0x34,0x31,0xF7 Get file name of Hot list #15 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x0F,0x34,0x32,0xF7 Get file name of Hot list #16 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x10,0x34,0x33,0xF7 Get file name of Hot list #17 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x11,0x34,0x34,0xF7 Get file name of Hot list #18 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x12,0x34,0x35,0xF7 Get file name of Hot list #19 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x13,0x34,0x36,0xF7 Get file name of Hot list #20 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x17,0x01,0x14,0x34,0x37s,0xF7 21

Command Category Code Command Example Example Command Code * Red points are variable Remark [GET HOT IN XX] 9 24 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x01,0x33,0x35,0xF7 start time code in HOT #01 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x02,0x33,0x36,0xF7 start time code in HOT #02 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x03,0x33,0x37,0xF7 start time code in HOT #03 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x04,0x33,0x38,0xF7 start time code in HOT #04 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x05,0x33,0x39,0xF7 start time code in HOT #05 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x06,0x33,0x41,0xF7 start time code in HOT #06 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x07,0x33,0x42,0xF7 start time code in HOT #07 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x08,0x33,0x43,0xF7 start time code in HOT #08 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x09,0x33,0x44,0xF7 start time code in HOT #09 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x0A,0x33,0x45,0xF7 start time code in HOT #10 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x0B,0x34,0x30,0xF7 start time code in HOT #11 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x0C,0x34,0x31,0xF7 start time code in HOT #12 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x0D,0x34,0x32,0xF7 start time code in HOT #13 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x0E,0x34,0x33,0xF7 start time code in HOT #14 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x0F,0x34,0x34,0xF7 start time code in HOT #15 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x10,0x34,0x35,0xF7 start time code in HOT #16 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x11,0x34,0x36,0xF7 start time code in HOT #17 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x12,0x34,0x37,0xF7 start time code in HOT #18 Get track number and 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x13,0x34,0x38,0xF7 start time code in HOT #19 Get track number and start time code in HOT #20 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x18,0x01,0x14,0x34,0x39,0xF7 22

Command Category Code Command Example Example Command Code * Red points are variable Remark [GET PRG NO] 9 28 Get Program number 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x1C,0x00,0x33,0x37,0xF7 [GET PRG FILE] 9 29 Get program file name 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x1D,0x00,0x33,0x38,0xF7 [GET PRG FILE XXX] 9 30 Get file name of program #0001 Get file name of program #0002 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x1E,0x04,0x30,0x30,0x30,0x31,0x46, 0x45,0xF7 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x1E,0x04,0x30,0x30,0x30,0x32,0x46, 0x46,0xF7 [GET PRG TTL] 9 31 Get total Number of program 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x1F,0x00,0x33,0x41,0xF7 [GET TRP DIR] 9 33 Get playback direction 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x21,0x00,0x33,0x43,0xF7 [GET TRP SPD] 9 34 Get playback speed 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x09,0x22,0x00,0x33,0x44,0xF7 The parameter and checksum (written in red) are variable. The first 4 bytes are the file number ( 0000 to 2000 in ASCII). 23

4-7. Device status Command Category Code Command Example Example Command Code * Red points are variable Remark [GET POW STAT] 11 1 Power status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x01,0x00,0x31,0x45,0xF7 [GET WIN STAT] 11 2 Display window status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x02,0x00,0x31,0x46,0xF7 [GET DIM STAT] 11 3 dimmer status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x03,0x00,0x32,0x30,0xF7 [GET LOCK STAT] 11 4 Key lock status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x04,0x00,0x32,0x31,0xF7 [GET PITCH STAT] 11 5 Pitch status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x05,0x00,0x32,0x32,0xF7 [GET PITCH VAL] 11 6 Pitch value 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x06,0x00,0x32,0x33,0xF7 [GET KEY STAT] 11 7 Master key status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x07,0x00,0x32,0x34,0xF7 [GET PRS 5] 11 8 Preset setting value of #005 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x08,0x01,0x05,0x32,0x42,0xF7 [GET UBL VOL] 11 9 Volume 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x09,0x00,0x32,0x36,0xF7 [GET FW VER] 11 10 Firmware version 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x0A,0x00,0x32,0x37,0xF7 [GET DRV VER] 11 11 Drive firmware version 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x0B,0x00,0x32,0x38,0xF7 [GET DEV ID] 11 12 MAC address 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x0C,0x00,0x32,0x39,0xF7 [GET PPWD] 11 14 Password 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x0E,0x00,0x32,0x42,0xF7 [GET AVAILABLE PSTAT] 11 15 Power status 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x0F,0x00,0x32,0x43,0xF7 [GET CUR MEDIA] 11 18 Current Media 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x12,0x00,0x32,0x46,0xF7 [GET ALV 5] 11 19 System setting value of #0005 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0B,0x13,0x04,0x30,0x30,0x30,0x35,0x46, 0x39,0xF7 The parameter and checksum (written in red) are variable. The first 4 bytes are the System setting index number ( 0000 to 0008 in ASCII). 24

4-8. Get list Category Command Command Example Example Command Code * Red points are variable Remark Code [GET MEDIA LIST] 13 1 No answer (refresh) 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x01,0x00,0x32,0x30,0xF7 [GET MEDIA TTL] 13 2 Number of Media 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x02,0x00,0x32,0x31,0xF7 [GET MEDIA X] 13 3 Media type of #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x03,0x04,0x30,0x30,0x30,0 x31,0x45,0x37,0xf7 [GET MSV LST] 13 4 No answer (refresh) 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x04,0x00,0x32,0x33,0xF7 [GET MSV TTL] 13 5 Number of Server 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x05,0x00,0x32,0x34,0xF7 [GET MSV X] 13 6 Server name of #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x06,0x04,0x30,0x30,0x30,0 x31,0x45,0x41,0xf7 [GET FDR TTL] 13 7 Number of Folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x08,0x00,0x32,0x37,0xF7 [GET FDR LST X] Folder List of #0003 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x07,0x04,0x30,0x30,0x30,0 13 8 No answer (refresh) x33,0x45,0x44,0xf7 [GET FDR XXXX] 13 9 #0005 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x09,0x04,0x30,0x30,0x30,0 x35,0x46,0x31,0xf7 #0001 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x09,0x04,0x30,0x30,0x30,0 x31,0x45,0x44,0xf7 #0002 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x09,0x04,0x30,0x30,0x30,0 x32,0x45,0x45,0xf7 [GET SND LST X] 13 10 #0007 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0A,0x04,0x30,0x30,0x30,0 No answer (refresh) x37,0x46,0x34,0xf7 [GET SND TTL XXXX] 13 11 number of sound file in #0008 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0B,0x04,0x30,0x30,0x30,0 x38,0x46,0x36,0xf7 number of sound file in #0001 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0B,0x04,0x30,0x30,0x30,0 x31,0x45,0x46,0xf7 [GET SND XXXX YYYY] File name of first track in #0001 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0C,0x08,0x30,0x30,0x30,0 13 12 x31,0x30,0x30,0x30,0x31,0x42,0x35,0xf7 [GET M3U LST XXXX] #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0D,0x04,0x30,0x30,0x30,0 13 13 No answer (refresh) x31,0x46,0x31,0xf7 [GET M3U TTL XXXX] number of program file in #0001 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0E,0x04,0x30,0x30,0x30,0 13 14 x31,0x46,0x32,0xf7 [GET M3U XXXX YYYY] 13 15 File name of first program file in #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x0F,0x08,0x30,0x30,0x30,0 folder x31,0x30,0x30,0x30,0x31,0x42,0x38,0xf7 [GET PPL LST XXXX] 13 16 #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x10,0x04,0x30,0x30,0x30,0 No answer (refresh) x31,0x46,0x34,0xf7 [GET PPL TTL XXXX] 13 17 number of hot list file in #0001 folder 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x11,0x04,0x30,0x30,0x30,0 x31,0x46,0x35,0xf7 [GET PPL XXXX YYYY] 13 18 File name of first hot list file in #0001 0xF0,0x00,0x40,0x03,0x11,0x01,0x00,0x0D,0x12,0x08,0x30,0x30,0x30,0 folder x31,0x30,0x30,0x30,0x31,0x42,0x42,0xf7 The parameter and checksum (written in red) are variable. The first 4 bytes are the number ( 0000 to 9999 in ASCII). * 2 The parameter and checksum (written in red) are variable. The first 4 bytes are the folder number ( 0000 to 9999 in ASCII).The file number ( 0000 to 9999 in ASCII) follows it. * 2 * 2 * 2 25