Installation Instructions Models FCM-6 / LCM-8 / SCM-8 Model CSB

Similar documents
Installation Instructions Model RNI

Installation Instructions Model PSX-12

Installation Instructions Model FMT

Installation Instructions Models CC-5 / CC-2

INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches)

Installation Instructions Model PSC-17C

Installation Instructions Model LPB

CAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM, OD-LP, OD-BP, OD-GP, REMBOX2, REMBOX4, XLS-MLE6-ADPT,

Installation Instructions Model ZAM-180

Installation Instructions Model NIC-C

MXL/MXLV 19 Rack Mount Fire Alarm Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3

MXL / MXLV Enclosures & Equipment

MXL / MXLV Rack-Mount Fire-Alarm Equipment

INSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card

Installation Instructions Model SNC Serial Network Card for USB Application with Windows

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

Installation Instructions

CP150B Vandal & Weather Resistant Keypad Security Systems

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

PowerCore Model TEC-10 Installation Manual

ATP1000 Touchpad/Display Installation Instructions

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

MS-7000: SuperStar Reader

FC-25/50DA Main Circuit Board Replacement Product Installation Document

NFS NFS-3030 NFS2-640 NFS-640 NFS-320 NCA NCA-2 DVC-EM ONYXWorks

E2460GS Oscilloscope Upgrade Kit

INSTALLATION INSTRUCTIONS

Product and functional description

C5 Series Stainless Steel Photoelectric

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

Wireless keypad PRF-LCD-WRL

MODEL FPI-32 PROGRAMMER/TESTER Operations Manual

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Fire Safety. Installation Instructions Model ACM-1 Audio Control Module INTRODUCTION OPERATIONS

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

Technovision Inc. CD-ROM Audio Sampler. Repair Manual

The Model Scalance X204-2 Multimode and X204--2LD Single

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Access control panel U-Prox IC E (Elevator control)

AE21 SERIES DISPLAY CONTROL TERMINAL

PowerView Model PV485. Installation Manual Section 78

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

Lock Parts. Keys. Key Insertion. Front Unit. Rear Unit. Product Guide. Standard Keypad Bolt Mechanism. Connection Options

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

1. Unpacking the System

S7999D SOLA Operator Interface Display

Redundant Master Controller Installation Instructions

TruPortal Output Expansion Board Quick Reference

Desigo Fire Safety Modular system

INSTALLATION INSTRUCTIONS

Product Data Sheet. Hochiki 8 Way I/O Card. Features

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

SERVICE MANUAL MODEL SSW-521-D2-ADA

Keypad Lock. Operation and Service Manual. Order parts online

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

INSTRUCTION/INSTALLATION SHEET lyriq Studio Keypad

icp installation guide

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

FC726 Fire control panel

APPENDIX FOR AccuLINK (CSG-M) Revision 17.01

EP-ELVCTL Elevator Control (NION-16C48M)

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

FC724 Fire control panel

FC722 Fire control panel

Figure 36. Connecting the 24V/DC power supply

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

MXLV Multiplex Emergency Voice Alarm/Communication System

In the following learning unit, you receive a function overview of the DCS-IP-gateway regarding: - Set-up

TURN-O-MATIC INSTALLATION GUIDE

Product Guide. Key Button. Pull Handle

Model XAV2 & XAV2-LED System Installation

FE Series Photoelectric Sensors

The Power Generation Display Unit is available in two sizes as described in the following table:

MXLV Multiplex Emergency Voice Alarm / Communication System

mbc082 Bus Converter

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Instruction Sheet Board Style Low Water Cutoff

Room Pressurization Controller Electronic Output

Signal Tower KombiSIGN 50

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

TruPortal Dual Door Interface Module Quick Reference

Quick Installation Guide

4100/ VDC Converter Installation Instructions

A-100G6 - Basic frame assembly diagram

Product and functional description

Terminal Equipment Controller Enclosure

Network Camera Quick Operation Guide

232iLM Keypad Installation and Programming Instructions

For Powerful Digital Marketing and Total Multimedia Solution DV-6664 & DV-6664T. User s Guide version 1.0

Wireless door phone INSTALLATION AND USER S GUIDE. Ed V11 AG 651 AG 652

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

INSTRUCTION MANUAL RA 19-4C RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF 300W, 600W, 1200W, 1500W SERIES POWER SUPPLIES

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

AC5160 SiPass integrated controller kit

Installation Instructions. Product Summary. Installation Guidelines. Tools and Equipment Needed. Table 1. Touchpad Power Usage

Transcription:

Installation Instructions Models FCM- / LCM- / SCM- Model CSB Control Module / LED Control Module / Switch Control Module CAN Sounder Board INTRODUCTION The Models FCM-, LCM- and SCM- from, are similar in appearance and identical in installation. Model FCM- Control Module (Figure ) contains six sets of three pushbutton switches and their corresponding LEDs. The ON and AUTO switches both have one bi-color (red/green) LED while the OFF switch has one bi-color and one yellow LED. The functions of the switches and LEDs are programmed using the Zeus Tool (Refer to the Zeus Quick Start Guide, P/N -). All LEDs can be programmed ON, OFF, or FLASHING. The FCM is designed for general control requiring ON/OFF/AUTO operation. Model LCM- LED Control Module (Figure ) contains eight pairs of LEDs. Each pair contains one bi-color (red/green) and one yellow LED. The functions of the LEDs are programmed using the Zeus Tool (Refer to the Zeus Quick Start Guide, P/N - ). All LEDs can be programmed ON, OFF, or FLASHING. These LEDs are used for fire system status annunciation. Model SCM- Switch Control Module (Figure ) contains eight switches and eight pairs of LEDs. Each pair contains one bi-color (red/green) and one yellow LED. The functions of the switches and LEDs are programmed using the Zeus Tool (Refer to the Zeus Quick Start Guide, P/N -). All LEDs can be programmed ON, OFF, or FLASHING. The SCM is used for manual control of the fire system. Figure FCM- Control Module Figure LCM- LED Control Module Figure SCM- Switch Control Module P/N -- Building Tec echnologies Division

The Model CSB CAN Sounder Board from Siemens Industry, Inc., (P/N -) is an optional module that can be ordered separately. It contains a sounder (buzzer) that can be used with the SCM- or FCM- to provide audible feedback to indicate that a switch closed properly and communication was successful. The CSB requires no programming. Buzzer Figure CSB Sounder Board All modules mount on an ID-MP mounting plate which is then mounted on the inner door of a CAB enclosure or the outer door of a REMBOX enclosure. The mounting plate can hold either SCMs/LCMs or FCMs or FCM and SCMs/LCMs. OPERATION FCM Controls and Indicators The FCM contains six sets of three pushbutton switches and their corresponding LEDs. Pressing any of the six ON, OFF, or AUTO switches generates a unique CAN message on the bus to the NIC that indicates which switch was pressed. A CAN message from the NIC to the FCM produces a preprogrammed output to the corresponding LED (ON, FLASHING, or OFF). An open collector is provided for connection to the CAN Sounder Board (CSB), a separate audio module. The CSB provides an audible feedback to indicate that the switch closed properly and that communication between the FCM and NIC was successful. LCM Controls and Indicators The LCM contains eight pairs of LEDs. A CAN message from the NIC to the LCM produces a preprogrammed output to any of the corresponding LEDs (ON, FLASH- ING, or OFF). SCM Controls and Indicators The SCM contains eight switches and eight pairs of LEDs. Each switch is associated with a pair of LEDs. Pressing of any of the eight switches generates a unique CAN message on the bus to the NIC that indicates which switch was pressed. A CAN message from the NIC to the SCM produces a preprogrammed output to the corresponding LED (ON, FLASHING, or OFF). An open collector is provided for connection to the CAN Sounder Board (CSB), a separate audio module. The CSB provides an audible feedback to indicate that the switch closed properly and that communication between the SCM and NIC was successful. CSB Controls and Indicators The CSB contains a sounder (buzzer) that sounds when any switch on an FCM or SCM is pressed. Only one CSB is required for audible feedback; more can be connected to increase the volume if needed. PRE-INSTALLATION Set the board address for each FCM/LCM/SCM using both of the ten-position rotary switches located on the back of the board (See Figure ). Each of these addresses must be a sub-address of the NIC and must be the same as the addresses assigned in the Zeus Programming Tool. The CSB does not require address setting. After setting the address, label each switch or LED. When viewed from the front panel of the FCM/LCM/SCM, the labels are on the left and the control switches and LEDs are on the right. Refer to the Zeus configuration for the address of each module and its assigned functions. Remove the label strip from its slot, and type or print a brief function identifier for each switch. After completing the label strip, insert in back into its slot (See Figure ). P/N --

P PLUG-IN CABLE CONNECTION ROTARY ADDRESS SWITCHES P Figure FCM-, LCM-, SCM- Address Switches And Cable Connections Figure Inserting A Label Into The Back Of The FCM- INSTALLATION FCM-, LCM-, and SCM- (Refer to Figure.). Hold mounting bracket Model ID-MP so that the words UP are at the top.. Place each FCM/LCM/SCM in the desired position on the mounting bracket, aligning the two studs in the smaller holes on the bracket. Secure with a - nut on each threaded stud.. If all of the positions on the mounting plate are not filled with FCM/LCM/SCM modules, install a Control Module Blank Plate BCM in each of those positions by aligning the two studs in the smaller holes on the bracket and securing with a - nut on each threaded stud.. Position the filled mounting bracket over the two studs on the back of the inner door, so that the modules face through the opening and secure with a - nut on each threaded stud.. Repeat steps through until all FCM/ LCM/SCM modules are installed. Figure Installing FCM-, LCM-, SCM- Modules. Install a blank plate, Model ID-SP, in unused spaces on door and secure with - nuts. Refer to Models CAB-BD/-RD and CAB-BD/-RD Installation Instructions, P/N - for more information. P/N --

CAN Sounder Board (Refer to Figure.) The CSB is normally positioned at the last FCM, LCM or SCM. If desired, multiple CSBs can be installed. The CSB mounts on the stud of the FCM/LCM/SCM module that it connects to.. Determine the position of the CSB on the ID-MP Mounting Plate. (This is normally at the last FCM, LCM or SCM module.). If necessary, remove - nut from stud of FCM/LCM/SCM where CSB is to be mounted.. Place mounting hole on the CSB over stud.. Secure with - nut supplied with FCM/LCM/SCM. ID-MP MOUNTING PLATE SCM- MODULES FCM- MODULE CSB SOUNDER BOARD BUZZER Figure Mounting The CSB WIRING (Refer to Figure.) Remove all system power before installation, first battery then AC. (To power up, connect the AC first, then the battery.) Each FCM/LCM/SCM module is a node in the CAN bus. Each FCM/LCM/SCM connects through the CC-/CC- CAN bus via a plugin cable to the NIC or to another FCM/LCM/SCM module. Up to FCM/LCM/SCM modules, in any combination, can be connected to the CAN bus of each NIC. Each FCM/LCM/SCM/CSB module is shipped with one CCS cable. P/N --

P INSTALL CAN TERMINAT P/N - (SHIPPED WITH NIC-C) P P TO CC-/CC-, P P LCM- SCM- P LCM- SCM- P LCM- SCM- P CABLE MODEL # CCL P FCM- P P LCM- SCM- P P LCM- SCM- P LCM- SCM- P P P P P LCM- SCM- P LCM- SCM- P LCM- SCM- P P FCM- P P LCM- SCM- P P LCM- SCM- P LCM- SCM- P Buzzer CSB CABLE MODEL # CCS Figure Typical Wiring For FCM-, LCM-, SCM- And CSB Cable connections for FCM/LCM/SCM/CSB modules are shown in the following table and in Figure : FCM/LCM/SCM/CSB CABLE CONNECTIONS Cable Description Part Number Connection CCL CCS CAN-CABLE-Lon g in., -conductor CAN-CABLE-Shor t ½ in., -conductor - Connects from row to row (on door) for FCM/LCM/SCM/CSB modules. Also connects from P on CC-/CC- to first FCM/LCM/SCM - Connects FCM/LCM/SCM/CSB modules to FCM/LCM/SCM/CSB modules in a single row P/N --

H SLOT SLOT TO PSC- TB + TB - CCL TO FRONT DO (P/N -) P L V M + - P C N A E/E a c a c P CC- / CC- SLOT SLOT Figure Connecting Power For FCM-, LCM-, SCM- Modules Mounted In CAB Enclosures The CAN bus requires a S resistance at each end of the loop. Refer to the NIC-C Installation Instructions, P/N - for details about CAN termination. ELECTRICAL RATINGS V Back Plane Current Screw Terminal V Current ma max + ma per active LED.V Back Plane Current V Standby Current ma max + ma per active LED Output Power CAN Network Pair V peak to peak max. ma max. (during msg transmission) P/N --

This page has been left intentionally blank. P/N --

This page has been left intentionally blank. For CE applications in Cerberus E systems refer to Installation Instruction A-A-B (English) or A-A-A (German). Florham Park, NJ Siemens Canada Limited Kenview Boulevard Brampton, Ontario LT E Canada Siemens Gebäudesicherheit GmbH & Co. ohg D- München P/N --