TDM-100/150 TO NMD-50 CONVERSION PROCEDURES RL5000

Similar documents
TDM To MiniMech conversion ProceDure

EMV 330 CARD READER UPGRADE

SECURITY MODULE UPGRADE

T9 EPP KEYPAD FIELD UPGRADE

Serial Printer Controller

Serial Printer Controller. 91xx / Mako / 97xx. TDN Oct 09, 2012

System Storage EXP3000 Rack Installation Instructions

X-SCALE TO X2 CONVERSION

USB MODEM UPGRADE INSTALLATION/SETUP PROCEDURES (MODELS RL/FT5000/RT2000)

Megatouch FORCE Monitor Chassis Board Replacement

9600 PCI EPP Keypad and

Peel/Rewind Upgrade Kit

Rack Installation Instructions

IBM. Rack Installation Instructions

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Rack Installation Instructions

Rack Installation Instructions

Royal RVV-500 (B) Retrofit Kit

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Rack Installation Instructions

Controller PC Hard Drive

Print Mechanism Maintenance Kit

To connect the AC adapter:

Codonics Virtua Virtua-2 Optical Drive Replacement

SPEECH UPGRADE INSTALLATION GUIDE (MODEL 9100)

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Removing and Replacing Parts

INSTALLATION INSTRUCTIONS

Encore XT Manual Gun Upgrade Kit

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

S4M 10/100 Internal ZebraNet PrintServer, Wireless Print Server, Parallel Port, and No Comm Option Kits

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

INSTALLATION INSTRUCTIONS

Service & Maintenance

APES-14 HD-6500 & HD-7000 Version Operator s Training Manual

Dell Latitude C800 Service Manual

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Z Series and S4M Ribbon/Head Open Sensor Assembly

Standard icontrol Power Supply Kit

Field Service Guide Supplement for the NS 7000/030

Installing the Server into a Rack

Star Trac Fitness E-ST 5090 Stepper. Install Guide

Oracle <Insert Picture Here>

Removal and Installation8

How To Install: C4000 EMV Upgrade Kit

Power Supply, 17-inch

AutoScan to MultiScan Replacement Kit

TURN-O-MATIC INSTALLATION GUIDE

Upgrade Instructions Printer Terminal Holder

Upgrading LVDS Cables Instruction Sheet

EMC 10T "CE" Mechanical Upgrade Procedure

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Rear Consumer LCD Hinge Assembly Large Displays

Assembly and Setup Manual

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

Dell Latitude C800 SERVICE MANUAL. support.dell.com

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Model RL1600 QUICK REFERENCE GUIDE TDN THIS AREA FOR SERVICE PROVIDER CONTACT INFORMATION:

Assembly Instructions for #5630 Medication PalWOW

Installing a Power over Ethernet injector

E2460GS Oscilloscope Upgrade Kit

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

CAMERA ASSEMBLY. Removal/Replacement of the Camera Box Assembly APR-CA. Install Camera Assembly. Remove Camera Assembly

Z Series and S4M Ribbon Take-Up Spindle Maintenance Kit

Installation Instructions

Kit# KOV ModBox IR REMOTE CONTROL KIT

Installation Instructions

Replacement Instructions

Instructions to Install Retrofit Kit 6/7000 Machine

527F Dual PC Option Installation Guide as replacement for 32MP made by Fadal

HD Flex Zero RU Cassette Holder and Bracket

PC9/P9 CPU Card Replacement

Cutter Option Installation Instructions

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Installation Instructions

Plasma Panel Replacement Guide DU-42PX12X

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

G12/G12x USER S MANUAL

Removal and Installation 8

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

Replacing the Billboard Diagnostic Camera

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Assembly and Setup Manual

imac Intel 21.5" EMC 2638 RAM Replacement

Validator Update Instructions for Rowe BC1200 $1 - $20

E1135C PDU and Pod Upgrade Procedure

A-dec 584 Monitor Mount on a Central Cabinet

Additional Help For additional installation instructions and videos, please visit our website at What s Included

Sabio Digital SD-KN1 Notebook Assembly Guide

Mac mini Mid 2011 IR Sensor Replacement

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Shop Fox Fence Kit Installation Instructions:

SSD Dual Drive Installation

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

Dell Inspiron XPS and Inspiron 9100 Service Manual

BL-FLOWSTN-P FlowStation Module Installation Guide

Transcription:

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES RL5000 TDN 0702-00062 March 7, 204 Corporate Headquarters 2405 B Street Long Beach, MS. 39560 Phone: (800) 259-6672 Fax: (228) 868-9445 COPYRIGHT NOTICE 204 Triton. All Rights Reserved. TRITON logo is a registered trademark of Triton Systems of Delaware, LLC

Document Updates March 2005 March 204 Original Corrections to part numbers.

PURPOSE This guide covers the steps for replacing your TDM-00 or TDM-50 dispenser in the Model RL5000 ATM with an NMD- 50 multi-cassette dispenser. This procedure includes a list of all tools and hardware necessary for the conversion as well as the steps involved. SCOPE This procedure applies to all service personnel involved in the process of maintaining or converting Triton ATMs. APPLICATION The two (2) conversion kits available depend on the Model RL5000 unit cabinet you currently have. The following guidelines will determine which kit is required to upgrade your ATM: Units built with serial numbers Before LRL504293385 require kit P/N 06200-0004. These cabinets are identified with a vault door T-Handle installed. Units built thereafter require kit P/N 06200-0003. These cabinets (current) are identified with a vault door Lift handle. How to Determine Unit Builds To determine when your unit was built, the serial number (located on the affixed label inside the control panel) has a julian date located in the block of numbers. For example, in the serial number mentioned above, LRL504293385, the 04293 is the year (04) and julian day (293th day of the year) that the unit was built. Section - This section covers the conversion procedures with older style cabinets (P/N 06200-0004). Section 2 - This section covers the conversion procedures with the current cabinet.

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES REQUIRED PARTS AND TOOLS TOOLS REQUIRED Slotted and Phillips Screwdriver /32" (9mm) and 7/6" ( mm) Nut Driver TDM to NMD-50 CONVERSION KIT (P/N 06200-0004) "T-Handle" Cabinet PARTS SUPPLIED PART NUMBER DESCRIPTIO N QUANTIT Y 09200-025 Power Supply 09005-0350 NMD-50 Mechanism (w/2 Cassettes and Reject Vault ) 030-02033 Bracket, L-shaped, Slide Stop 02054-00235 Screw, 4mm x 0mm, Low Profile, Slotted Panhea d 6 030-00760 Handle Bracket (Dispenser ) 2 0060-0046 Connector, Quick Connect, Molex 03072-00009 Clip, Panduit Adhesive Cable 6 03082-00000 Custom Slide, 8" 2 030-05023 Slide Spacer Bracket 09600-00057 Data Cable, EJ to Mech 0920-003 Data Cable, EJ to Docking Board 0920-07029 DC Power Cable, NMD-50 09200-00075 EJ Module, Yello w 030-048 Bracket, EJ 0920-00367 Ground Wire, NMD-50 02302-00032 Hex Bolt, /4-20 x 3/8", Zinc Steel 3 02309-00049 Lock Washer, /4", Zinc Steel 3 0230-0004 Kep Nut, /4-20 2 0920-00367 Dispenser Ground Wir e 03072-0005 Ty Wrap 3 03072-0009 Flat Cable Clamp, Adhesiv e 03072-00002 Snap-in Connector, Plasti c 0700-00024 Model RL5000 Quick Reference Card (NMD-50) 02054-00320 8-32 x 3/8 Phil Truss HD Machine Screw 2

DISASSEMBLY PROCEDURES Before proceeding, follow these steps to remove power from the ATM: Enter Management Functions > System Parameters > Shut Down the Terminal. When prompted, turn power OFF on the ATMs power supply. Unlock and open the ATM control panel. Turn the power switch to the OFF (0) position. If possible, unplug the ATM power cord at the wall outlet.. Power Supply - Open the control panel. Disconnect all cables (AC/DC) from the terminal power supply (Figure ). Lift the control panel slightly. Using an /32" nut driver, loosen the two (2) nuts that secure the power supply to the cabinet (Figure 2). Slide the power supply towards the rear of cabinet and remove from the unit. Figure. Disconnect all cables from power supply. Figure 2. Loosen the 2 nuts that secure power supply. 2. Dispenser Cable Harness - Using a 7/6" nut driver, remove the screw that secures the ground wire (Figure 3). After removing the ground wire, reinstall the screw. Next, disconnect the Dispenser data cable (RJ-45 end) connected to the Docking board assembly. Loosen/turn the cable bundle guides (Figure 4) and separate data cable from bundle. Feed the dispenser data, power, and ground wire harness down to the vault area through the cable access hole in Figure 5. Figure 3. Disconnect ground wire. Figure 4. Loosen guides. Figure 5. Feed cables down to vault area. 3. TDM Dispenser - Open the cabinet vault door. Release the locking slide rail and fully extend the dispenser from the cabinet. Rotate the dispenser mounting platform 80 to the Service position. Locate the spring-loaded locking pin on the underside of the mounting tray (Figure 6). Pull the pin down and turn the tray clockwise (Figure 7) so the note and reject cassettes can be accessed from the front. Release the locking pin and move the platform back and forth slightly to ensure the pin snaps into place to the Service position (Figure 8). Figure 6. Pull release pin. Figure 7. Rotate mechanism clockwise. Figure 8. Mech in Service position. 3

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES 4. Disconnect the power and communication (Comms) cables from the dispenser (Figure 9). Carefully cut any Ty wraps that are securing the cables to the dispenser. Remove the cables from the cabinet. Remove the note and reject cassettes. Using a phillips-head screwdriver, remove the four (4) or six (6) mounting screws that secure the dispenser to the swivel platform (Figure 0). Remove the TDM dispenser mechanism. Ferrite Figure 9. Power and Comm cable disconnected. Figure 0. Remove mounting screws. 6. Dispenser Slide Rail Hardware - With the tray extended out, use a phillips screwdriver to remove the screws (3 on each side) that secure the slide rails to the mounting brackets (Figure ). Remove the slide rails (with mounting tray attached) from the cabinet. UPGRADE KIT ASSEMBLY PROCEDURES. Right Side Slide Assembly - On a flat surface, assemble the right side slide assembly. Extend one of the slide rails (Figure ) and secure to the slide Figure. Remove slide rails w/tray. spacer bracket with four (4) Truss phillip head screws (Figures and 2). Mount this assembly to the right cabinet bracket shown in Figure 3. Using a 7/6" nut driver, secure the assembly to the cabinet bracket using two (2) 3/8" hex bolts and lock washers. When installed, the slide rail (pushed in) should be even with the door flange (Figure 4). Figure. Slide rail extended. Figure 3. Cabinet bracket. Figure 4. Assembly mounted to cabinet. Figure 2. Slide rail/spacer assembly. 4

2. Left Side Slide Rail - Mount the other slide rail to the left cabinet bracket (Figure 5) using four (4) Truss phillip head screws (Figure 6). Use the diagram below for screw locations. Note: When installing slide rail, ensure the power/ phone cables are tucked behind the cabinet bracket as shown in Figure 5. Slide rails will be offset when extended. Figure 5. Cabinet bracket. Figure 6. Slide rail installed. 3. Electronic Journal (EJ) and Bracket - The EJ (yellow), bracket, and cables (2 - EJ to dispenser, EJ to docking board) should be pre-assembled in the kit. If they are not, use Figure 7 as a reference for assembly. Locate the two (2) bolts in the upper right of the vault area (Figure 8). Mount the EJ assembly to the bolts (cable connects towards rear of cabinet) and secure with the two (2) Kep nuts provided using a 7/6" nut driver (Figure 9). Figure 7. EJ and hardware assembly. Figure 8. Mounting bolt location. Figure 9. EJ mounted. 4. Dispenser Ground - Remove the cabinet ground bolt (Figure 0), if installed. If no bolt is available, one is included in the kit. Install the dispenser ground wire included and secure both ground wires with the bolt previously removed or one included (Figure ). The other end of ground wire will attach to the NMD-50 when installed. Dispenser ground Figure 0. Remove door ground bolt. Figure. Dispenser ground installed. 5

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES 5. Dispenser Power and Data Cables - Feed the EJ to Docking board cable (RJ-45 connector end) through the control panel access hole shown in Figure 2. Feed the dispenser power cable (insert) also up to the control panel (0-pin connector end). These 2 cables will be connected in later steps. Route the 2 cables in the vault area (EJ to dispenser, dispenser power cable end) in the existing cabinet cable clips (Figure 3). Dispenser power cable Figure 2. EJ to Docking board cable. Figure 3. Route power/data cables. 5. Dispenser - Extend the slides fully. Ensure all cables in vault area have been moved out of way before installing mechanism. Remove cardboard support from mechanism cassettes. With 2-personnel, lift the NMD-50 by the green handles and align the rails on the dispenser with the slide rails. Start inserting the rail on the RIGHT first, then the LEFT due to the offset of the rails (Figure 4). Slide mechanism up to the rail stops, then push the RIGHT release in, then LEFT (Figure 5) and continue sliding mechanism fully into cabinet. Repeat extending/inserting mechanism into cabinet a few times to ensure no binding on slide rails. Release tab Figure 4. Rails extended (offset). Figure 5. Push release tabs in. 6. Dispenser Cables - Connect the power, data, and ground wires to the NMD-50 as shown in Figures 6 and 7. Route the cables through the cable clips attached to the mechanism covers (Figure 8). Ground wire routes down behind slide and through the lower cable clips. Ground wire routing Figure 6. Power cable connection. Figure 7. Data/ground connections. Figure 8. Route cables thru clips. 6

7. Power Supply/Cables - Open the control panel. Connect the EJ to Docking board cable (RJ-45 connector end) to the Dispenser port of Docking board. Route the cable through the cable guides (see Figure 4, Disassembly Procedures ). Next, install the new power supply by reversing the procedures in Step, Disassembly Procedures. Reconnect all power cables (AC/ DC) to the power supply (Figure 9). Reconnect ATM power cord to wall outlet, if applicable. Figure 9. Power supply connected. The following illustrations show the installation of the slide catch bracket to the dispenser slide rail. Tool required is a #2 flat-tip screwdriver. Installation time approximately less than 5 minutes. See table below to determine which type and placement for the catch bracket. NMD-50 Slide Stop (Model / Placement) M odel / Cabinet Bracket # RL55 (Business Hours / T-Handle) Placemen t 030-02032 Right side 030-02033 (Acute-angle 030-02032 (L-bracket) Step Fully extend mechanism. Remove screw shown from Right or Left side rail (see table). Retain screw. Step 2 Slide catch bracket through slot on front of rail (L-shaped or angle end pointing out). L-Bracket Step 3 Secure bracket with screw previously removed. Step 4 Slide mechanism back in cabinet. 7

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES REQUIRED PARTS AND TOOLS TOOLS REQUIRED Slotted and Phillips Screwdrivers /32" (9mm) and 7/6" ( mm) Nut Driver TDM to NMD-50 CONVERSION KIT (P/N 06200-0003) "Lift Handle" Cabinet PARTS SUPPLIED PART NUMBER DESCRIPTIO N QUANTIT Y 09200-025 Power Supply 09005-350 NMD-50 Mechanism (w/2 Cassettes and Reject Vault ) 030-02033 Bracket, Acute Angle, Slide Stop 02054-00320 8-32 x 3/8 Phil Truss HD Machine Screw 030-00760 Handle Bracket (Dispenser ) 2 0060-0046 Connector, Quick Connect, Molex 03072-00009 Clip, Panduit Adhesive Cable 6 03082-00000 Custom Slide, 8" 2 030-0594 Left Slide Bracket 030-0595 Right Slide Bracket 09600-00057 Data Cable, EJ to Mech 0920-003 Data Cable, EJ to Main Board 0920-07029 DC Power Cable, NMD-50 09200-00075 EJ Module, Yello w 030-048 Bracket, EJ 0920-00367 Ground Wire, NMD-50 0230-00024 Hex Nut, #8-32, Ext.Tooth Washer, Zin c 6 0230-0004 Kep Nut, /4-20 2 02054-00332 Cap Screw M4 x 0mm 6 03072-0005 Ty Wrap 3 03072-00002 Snap-in Connector, Plasti c 0700-00024 Model RL5000 Quick Reference Card (NMD-50) 8

DISASSEMBLY PROCEDURES Before proceeding, follow these steps to remove power from the ATM: Enter Management Functions > System Parameters > Shut Down the Terminal. When prompted, turn power OFF on the ATMs power supply. Unlock and open the ATM control panel. Turn the power switch to the OFF (0) position. If possible, unplug the ATM power cord at the wall outlet.. Power Supply - Open the control panel. Disconnect all cables (AC/DC) from the terminal power supply (Figure ). Lift the control panel slightly. Using an /32" nut driver, loosen the two (2) nuts that secure the power supply to the cabinet (Figure 2). Slide the power supply towards the rear of cabinet and remove from the unit. Figure. Disconnect all cables from power supply. Figure 2. Loosen the 2 nuts that secure power supply. 2. Dispenser Cable Harness - Using a 7/6" nut driver, remove the screw that secures the ground wire (Figure 3). After removing the ground wire, reinstall the screw. Next, disconnect the Dispenser data cable (RJ-45 end) connected to the Docking board assembly. Loosen/turn the cable bundle guides (Figure 4) and separate data cable from bundle. Feed the dispenser data, power, and ground wire harness down to the vault area through the cable access hole in Figure 5. Figure 3. Disconnect ground wire. Figure 4. Loosen guides. Figure 5. Feed cables down to vault area. 3. TDM Dispenser - Open the cabinet vault door. Release the locking slide rail and fully extend the dispenser from the cabinet. Rotate the dispenser mounting platform 80 to the Service position. Locate the spring-loaded locking pin on the underside of the mounting tray (Figure 6). Pull the pin down and turn the tray clockwise (Figure 7) so the note and reject cassettes can be accessed from the front. Release the locking pin and move the platform back and forth slightly to ensure the pin snaps into place to the Service position (Figure 8). Figure 6. Pull release pin. Figure 7. Rotate mechanism clockwise. Figure 8. Mech in Service position. 9

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES 4. Disconnect the power and communication (Comms) cables from the dispenser (Figure 9). Carefully cut any Ty wraps that are securing the cables to the dispenser. Remove the cables from the cabinet. Remove the note and reject cassettes. Using a phillips-head screwdriver, remove the four (4) or six (6) mounting screws that secure the dispenser to the swivel platform (Figure 0). Remove the TDM dispenser mechanism. Ferrite Figure 9. Power and Comm cable disconnected. Figure 0. Remove mounting screws. 6. Dispenser Slide Rail Hardware - With the tray extended out, use a phillips screwdriver to remove the screws (3 on each side) that secure the slide rails to the mounting brackets (Figure ). Remove the slide rails (with mounting tray attached) from the cabinet. 7. Mounting Brackets - Using an /32" nut driver, loosen the two (2) nuts that secure the brackets to the cabinet (Figure ). Remove the brackets. These will be replaced. Start two (2) more nuts (one each side) to the third bolt closest to rear of cabinet (Figure 2). Note: The cabinet ground wire is attached to the left side front bolt. You will have to temporarily remove this nut to remove the ground wire lug. Nut will be attached in later steps. Hex nuts w/tooth washer Figure. Side rails removed. Figure 2. Nuts started on bolts. 8. Tray Stop (Door) - Locate the tray stop mounted on the door (Figure 3). Remove this item from the door using a 7/6" nut driver.. Figure 3. Remove tray stop. 0

UPGRADE KIT ASSEMBLY PROCEDURES. Electronic Journal (EJ) and Bracket - The EJ (yellow), bracket, and cables (2 - EJ to dispenser, EJ to docking board) should be pre-assembled in the kit. If they are not, use Figure as a reference for assembly. Locate the two (2) bolts in the upper right, rear of the vault area (Figure 2). Mount the EJ assembly to the bolts (cable connects towards top of cabinet, Figure 3) and secure with the two (2) Kep nuts provided using a 7/6" nut driver. Figure. EJ and hardware assembly. Figure 2. Mounting bolt location. Figure 3. EJ mounted. 2. Slide Rail Mounting Brackets - Locate the two (2) mounting brackets in kit (Figure 4). There is a Left (L) and Right (R) specific. Mount brackets by first starting backslot (Figure 5) on the rear screw and rotating down over the other two (2) screws. Using an /32" nut driver, secure the hex nuts. Right Mounting brackets Left Figure 4. Rail mounting brackets. Backslot seated fully Figure 5. Mount bracket on rear screw first, then rotate down. * Important* Ensure all screws are fully seated in the bracket slots and not resting on bracket. Brackets must be level when installed! 3. Slide Assemblies - Install slide rails to the mounting brackets. Start a truss phillips screw in the second to last hole of the slide assembly first (Figure 6). Extend rails out and install the other two (2) screws and secure all. Push in slide rails. When installed correctly, the front of slide rails will be flush with mounting brackets (Figures 7 and 8). Figure 6. Slide rail. Figures 7 and 8. Slide rails flush w/bracket front.

TDM-00/50 TO NMD-50 CONVERSION PROCEDURES 4. Dispenser/Cabinet Grounds - Reconnect the cabinet ground wire removed in Step 7 (page ) to the front left screw. Install the dispenser ground wire included and secure both ground wires with the nut previously removed (Figure 9). The other end of dispenser ground wire will attach to the NMD-50 when installed. 5. Dispenser Power and Data Cables - Feed the EJ to Docking board cable (RJ- 45 connector end) through the control panel access hole. Feed the dispenser power cable (insert) also up to the control panel (Figure 0). These 2 cables will be connected in later steps. Route the 2 cables in the vault area (EJ to dispenser, dispenser power cable end) in the existing cabinet cable clips (Figure ). Figure 9. Ground wires installed. Dispenser power cable Figure 2. EJ and dispenser power cables. Figure. Route power/data cables. 6. Dispenser - Extend the slides fully. Ensure all cables in vault area have been moved out of way before installing mechanism. Remove cardboard support from mechanism cassettes. With 2-personnel, lift the NMD-50 by the green handles and align the rails on the dispenser with the slide rails. Insert the rails and slide mechanism up to the rail stops (Figure 2). Push the release tabs in (Figure 3) and continue sliding mechanism fully into cabinet. Repeat extending/ inserting mechanism into cabinet a few times to ensure no binding on slide rails. Release tab Figure 2. Insert mechanism to rail stop. Figure 3. Push release tab. 7. Dispenser Cables - Connect the power, data, and ground wires to the NMD-50 as shown in Figures 4 and 5. Route the cables through the cable clips attached to the mechanism covers (Figure 6). Ground wire routes down behind slide and through the lower cable clips. Note: Ensure ground wire doesn t catch on cabinet shoulder bolts when sliding mechanism into cabinet. Ground wire routing Figure 4. Power cable connection. Figure 5. Data/ground connections. 2 Figure 6. Route cables thru clips.

8. Power Supply/Cables - Open the control panel. Connect the EJ to Docking board cable (RJ-45 connector end) to the Dispenser port of Docking board. Route the cable through the cable guides (see Figure 4, Disassembly Procedures ). Next, install the new power supply by reversing the procedures in Step, Disassembly Procedures. Reconnect all power cables (AC/ DC) to the power supply (Figure 7). Reconnect ATM power cord to wall outlet, if applicable. Figure 7. Power supply connected. The following illustrations show the installation of the slide catch bracket to the dispenser slide rail. Tool required is a #2 flat-tip screwdriver. Installation time approximately less than 5 minutes. See table below to determine which type and placement for the catch bracket. NMD-50 Slide Stop (Model / Placement) M odel / Cabinet Bracket # Placemen t 030-02033 (Acute-angle 030-02032 (L-bracket) RL55 (Business Hours / Lift-Handle) RL525 (Level - Vault) 030-02033 Right side 030-02033 Left side Step Fully extend mechanism. Remove screw shown from Right or Left side rail (see table). Retain screw. Step 2 Slide catch bracket through slot on front of rail (L-shaped or angle end pointing out). Angle Step 3 Secure bracket with screw previously removed. Step 4 Slide mechanism back in cabinet. 3