ENMAT Premium Data Logger User Manual

Similar documents
Installation and User Guide. Version 0.6

Installation and User Guide. Version 1.1

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Comet Blu +USB User and Developer Guide

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

TM258LD42DT4L compact base M I/O - 24 V DC

KTA-250 Anemometer Alarm Card

NetBiter Serial Server User Manual

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

NetBiter I/O Extender User Manual

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description

RS485 MODBUS Module 6RO

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

Com X 210, Com X 510 Technical Datasheet

Communication Interface

TM258LF42DT compact base M I/O - 24 V DC - CANopen

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

TM258LF42DT compact base M I/O - 24 V DC - CANopen

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

RS485 MODBUS Module 8I8O

RTU560 Remote Terminal Unit Connections and Settings

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Power Serial Device Server

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Characteristics and functioning

Serial Communication Converters & Adapters Instruction Manual

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

MOTION COORDINATOR MC405 Quick Connection Guide

Quick Start Installation Guide

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

INSTALLATION MANUAL Z-UMTS

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

icex-cmtm General specs and Installation guide

4Trio Motion Technology3

-C5RS-LC RS232 EXTENDER

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

INTERFACES TRADITIONAL PC ADAPTER CARDS. DATA SHEET page 1/6. Description

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

TM258LD42DT4L compact base M I/O - 24 V DC

RTU32S RTU32S Series Small Compact Utility RTU

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

RTU32S RTU32S Series Small Compact Utility RTU

TM241CE40R controller M IO relay Ethernet

TM241CE24U controller M IO transistor NPN Ethernet

POWERWISE INDAC SETUP MANUAL

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

TM241CE24T controller M IO transistor PNP Ethernet

DGH A3000 Configuration Guide For use with DGH Modules

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

Installation & Operation Guide

COSMOS COLLECTOR X10 COSMOS X10 DATA COLLECTION AND REPORTING SYSTEM. User manual

TM241CE40R controller M IO relay Ethernet

Web-enabled DAQ System

Hot pluggable communication modules

TM241CE40R controller M IO relay Ethernet

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM241CE24T controller M IO transistor PNP Ethernet

LMC058LF42 compact base - 42 I/O - 24 V DC supply

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

TM241CE40T controller M IO transistor PNP Ethernet

Mega_Link Telemetry Communication System

Intech Micro 2400-A16-SD

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

TM258LF42DT compact base M I/O - 24 V DC - CANopen

Chapter 1. Introduction. Additional Documentation

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

Characteristics and functioning

Data Acquisition Package

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

DC561, digital input/output module,

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

TM241CEC24R controller M IO relay Ethernet CAN master

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

M-Bus-Logger Data Logger

MODEL: GR8-EM. Communication Adaptor GR8 Series

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Industrial Media Converters

Quick Guide Flex Gateway G2

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

NetCom Plus 113 (NetCom 113, NetCom 113 PRO)

RS 485 Mini Modbus 1AO

PSI-MODEM-SHDSL/SERIAL

Transcription:

Page 1

Information in this document is subject to change without notice. Copyright 2013 Envantage Ltd. All rights reserved. ENMAT is a trading name of Envantage Ltd. While the information contained in this document was correct at the time of printing, it may not be the latest version available. Please visit our website at http://www.en-mat.com to check for updates. Reproduction of any printed material, software or hardware without prior consent of Envantage Ltd is strictly forbidden. Page 2

This manual contains setup and general use instructions. Should you require any further information please contact the ENMAT support team on 0161 448 7722 Page 3

Contents 1. Specifications...5 2. Installation..7 3. Field Connections 9 4. After Sales Service..10 5. Guarantee.. 10 Page 4

Specifications Ethernet Speed: 10/100Mbs Protocols: HTTP, FTP, SMTP, SNTP, Telnet Modbus RS485 / RS232 Two serial bus connections are available for the connection of RS485 or RS232 Modbus devices. Mode RS485: 2-wire, half-duplex, un-terminated Baud: selectable up to 115200 bps Connector: 3- way, 5.08mm pitch, 2.5mm2 CSA Mode RS232: 3-wire, full-duplex Baud: selectable up to 115200 bps Connector: RJ45 Bus port Diagnostics COMMS port - RS232 A serial terminal is available for low-level configuration and diagnostic purposes. This is not usually needed but can be used in case of problems with the Ethernet connection, for example, unknown IP address. Baud: fixed at 115200 Mode: 8 None 1, hardware handshake Connector: 9-way female D-type Cable: null modem Page 5

Mechanical Dimensions: 157mm x 86mm x 58mm Weight: 0.5Kg Mounting: symmetrical DIN rail Connectors: 5.08mm pitch, 2.5mm2 CSA Electrical Power Supply: 12-24Vac/dc ±10% Consumption: <5W (typical) Fuse: 500mA resettable (internal) Input/Output Connections Digital Inputs 8 x S0 volt-free contact or open collector Digital Outputs 2 x change-over relays Analogue Inputs* 8 x 0-10Vdc (non-isolated) Page 6

The ENMAT Premium Data Logger is pre-configured before dispatch to customer site to send data to ENMAT Cloud Software or an ENMAT engineer will be installing as part of the service. For more information please see: http://www.en-mat.com/store/enmat-installation-services If we are dispatching we many need further information from you such as SMTP Server and Static assigned IP configuration. Please ask you systems administrator to contact ENMAT Support for more details. Installation The ENMAT Premium Data Logger is an Internet connected device for the collection, storage and transmission of meter data for energy management and environmental monitoring. Powered by a high speed ARM processor the ENMAT Premium Data Logger has the capacity to acquire, process, record, present and stream data from multiple energy meters, sensors and networked devices. The ENMAT Premium Data Logger has meter pulse inputs for direct connection to energy meters and analogue inputs for use with the LEM range of AC Current Transformers. The Modbus serial port enables communication with additional meters, Building Management Systems, PLCs and other networkable devices. TCP Modbus devices can also be read using the Ethernet network connection. Energy consumption is recorded at selectable intervals, typically ½ hourly. This data is stored on the ENMAT Premium Data Logger and automatically sent to a the ENMAT Cloud server software. Installation Procedure Using a standard Ethernet cable (RJ45 plugs), connect the ENMAT Premium Data Logger to the Ethernet network. Connect the field devices to the ENMAT Premium Data Logger IO terminals, such as a Modbus network or pulse meters, as described in the Field Connections section. Connect a suitable power supply to the Vin terminals. Page 7

Check the following: The green Power LED illuminates, indicating the power supply is connected The Input LEDs perform a start-up routine indicating the ENMAT Premium Data Logger processor is initialising, after which they will remain off The Status LED flashes periodically to indicate the ENMAT Premium Data Logger is operational Each time a pulse is detected at a digital input, the corresponding Input LED will flash. The Modbus network should be connected according to the remote device manufacturer s guidelines. The COM terminal at the ENMAT Premium Data Logger is not internally connected and is only intended to facilitate the connection of a suitable ground to the network cable shield. No termination resistor is installed in the ENMAT Premium Data Logger. Page 8

Field Connections Page 9

After Sales Service We will provide unlimited telephone support for 30 days following purchase of the product. Following this period, we will provide unlimited e-mail support. This will allow us to keep the cost of the product competitive. When contacting us for support, please have the following information to hand (or include in e-mail): Serial number of unit (usually on base of product) Where purchased from? (i.e. directly from us or a reseller) Your contact details including telephone and e-mail address Description of the problem Guarantee Your ENMAT product is guaranteed for 1 year from the date of purchase. Please keep your invoice as proof of purchase. Should a problem arise with the product, please contact: support@en-mat.com for technical assistance. If you wish to return your product, please contact us via the details on the back page and instructions for returning the product will be given. If you send any items back to us without arranging a returns number then we do not guarantee any repair or refund of the item. This guarantee does not affect your statutory rights. Envantage Ltd ENMAT Energy Management 8 Grange Lane Didsbury Manchester Greater Manchester M20 6RW Page 10 www.en-mat.com info@en-mat.com