Functions IOB BIP I/ O Module BACnet Modbus CEA 709 M Bus KX OPC IOB 550/551/552/553/554 V2 Datasheet #027119 WEB, STUDIO The IOB 55x Modules communicate over Ethernet/ IP in the BACnet/ IP network. They adhere to the BACnet Building Controller Profile (B-BC) and either expose their I/ O data points through BACnet server objects or actively fetch them from a BACnet server via BACnet client maps. According to the B-BC profile, the IOB 55x Modules support BACnet alarming, scheduling, and trending. They are BT tested and certified. ROC BACnet/ IP over Ethernet IX BACnet The IOB 55x I/ O Modules are equipped with two Ethernet ports including a builtin Ethernet switch. This allows for building a daisy chained line topology of up to 20 devices, which reduces costs for network installation. Dual Ethernet port devices also allow the setup of a redundant Ethernet installation (ring topol ogy), which increases reliability. The redundant Ethernet topology is enabled by the Rapid Spanning Tree Protocol (RSTP), which is supported by most managed switches. OPC XM-DA IOB IP -IX VC PC IOB 1 +2 3 4 B A 5 Automation Server CIP ACT 2 1 6 The IOB 55x Modules are equipped with a web interface to query the device sta tus and display or change each data point of the module. In addition to the BACnet object interface, the I/ O data points are exposed by the integrated OPC server providing SS encrypted web services (OPC XM DA) or UA Secure Conversation (OPC UA). The local display can be accessed via VC. IK ACT RI serial Base-T IX-110 power 12-35 VDC IPUT or 12-24 VAC, 40-70 Hz - + ~ ~ DC AC 16 17 y=f(x) IOB IP Mode The IOB 55x Modules can be switched to IOB IP mode using manual local oper ation. In IOB IP mode, the IOB 55x Modules extend IX Automation Servers, IOB 58x I/ O Controllers, and ROC Room Controllers with physical inputs and outputs via plug and play. Gateways ocal I/O ocal Operation and Override VIS, -STAT All IOB I/ O Modules are equipped with an CD display (128x64) with backlight and jog dial for manual local operation. Device and data point information is dis played in text form and via graphical symbols. POW-24B USB IX-202 GD + -IX Automation Server 1 24VAC/DC - + PWR EXT GD B A USB 2 USB 1 Ethernet 2 Ethernet 1 C B 2 A GD + - Intranet IOB-IP DI5 GD DI6 DI7 GD DI8 IOB-451 DAI Routers, IC IX I/ O integration through IOB IP via plug and play DO1 DO2 DO3 DO4 IOB-452 DO6 DO7 DO8 GD UI2 UI3 GD UI4 UI5 GD UI6 AO1 GD AO2 AO3 GD AO4 AO5 GD AO6 DO2 DO3 DO4 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI16 GD DI DI14 GD DI DO6 DO7 DO8 DO9 IOB-450 DI9 GD DI10 DI11 GD DI12 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI1 GD DI2 AO1 GD AO2 Features I/ O module with physical inputs and outputs Compliant with ASI/ ASHRAE 5 2012 and ISO 16484 5:2012 standard Ethernet/ IP network interface BACnet objects for integration in BACnet/ IP channels Interfaces BACnet Client Mappings to access to BACnet/ IP objects Fulfills the BACnet Building Controller Profile (B BC) Accessories Manual operation using the jog dial or VC client 78 B-BC (BACnet Building Controller) functionality, BT certified Supports BACnet Alarming, Scheduling, and Trending Connected to the IX Automation Server, ROC Room Controller and IOB 58x I/ O Controller via IOB IP 128x64 graphic display with backlight Automatic integration into device configurations with IX, ROC, and IOB 58x I/ O Controller ocal access to information about device and data points in clear text and symbols Easy device replacement without any additional software at the IX, ROC, and IOB 58x I/ O Controller Integrated web server for device configuration and monitoring data points Built-in OPC XM DA and OPC UA server Math objects to execute mathematical operations on data points
+~ -~ DO2 DO3 DO4 DO6 DO7 DO8 DO9 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI1 GD DI2 AO1 GD AO2 DO2 DO3 DO4 DO6 DO7 DO8 DO9 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI1 GD DI2 AO1 GD AO2 DI5 GD DI6 DI7 GD DI8 DI9 GD DI10 DI11 GD DI12 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI16 GD DI DI14 GD DI General Specifications Dimensions (mm) Specifications IOB BIP I/ O Module (IOB 55x) IOB 550/551/552/553/554 V2 Type IOB 550 IOB 551 IOB 552 IOB 553 IOB 554 Power consumption 4.5 W (Relays on) 4.5 W 4.5 W (Relays on) 4.5 W (Relays on) 4.5 W (Relays on) Universal (UI) 8 8 6 6 7 Digital (DI) 2 12 - - - Analog (AO) 2-6 6 4 Digital (DO) 8 (4 x Relay 6 A, 4 x Triac 0.5 A) Digital specification - 8 (8 x Relay 6 A) 5 (4 x Relay 16 A, 1 x Relay 6 A) 7 (5 x Relay 6 A, 2 x Triac 0.5 A) Please refer to the General and Specification of devices at the end of the IOB section for more details. Differential Pressure Sensor - - - - 0 500 Pa Order number Product description IOB 550 IOB BIP : 8 UI, 2 DI, 2 AO, 8 DO (4 x Relay 6 A, 4 x Triac 0.5 A) IOB 551 IOB BIP : 8 UI, 12 DI IOB 552 IOB BIP : 6 UI, 6 AO, 8 DO (8 x Relay 6 A) IOB 553 IOB BIP : 6 UI, 6 AO, 5 DO (4 x Relay 16 A, 1 x Relay 6 A) IOB 554 POW 24A POW 24B -TEMP2 107 x x 75 ( x W x H), DIM018, DIM019, DIM020, DIM021, DIM022 Installation DI rail mounting following DI 43880, top hat rail E 50022 Operating conditions Power supply Interface Resource limits Plug and play I/ O integration through IOB IP IOB BIP : 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 0.5 A), 1 Pressure Sensor IOB Connect power supply unit, 24 V DC, W Power supply unit with power connector 24 V DC, W External temperature sensor (TC10K) for use with IOB Universal s IOB BIP I/ O Module 0 C to 50 C, 10 90 % RH, non condensing, degree of protection: IP40, IP20 (terminals) 24 V DC / 24 V AC ±10 % via IX, ROC, or POW, or with IOB Connect, or via connecting of an external power supply to the upper left terminal 2 x Ethernet (Base-T): OPC XM DA, OPC UA, IOB IP, BACnet/ IP OPC data points BACnet notification classes 32 In BACnet mode, IOB BIP devices communicate through BACnet/ IP BACnet objects 1 per I/ O Trend logs (BACnet or generic) 10 (0 000 entries, 2 MB) BACnet client mappings 20 Total trended data points 10 BACnet calendar objects 10 Alarm logs 5 BACnet scheduler objects 5 Connections (ocal / Global) 200 / Math objects 20 IOB-580 BACnet I/O Controller Object IOB-IP Intranet BACnet/IP IOB-550 BACnet BACnet/IP IOB-551 Object BACnet Functions WEB, STUDIO ROC IX IOB Gateways VIS, -STAT DAI Routers, IC Interfaces Accessories buildings under control 79
Accessories Interfaces Routers, IC DAI VIS, -STAT Gateways IOB IX ROC WEB, STUDIO Functions DIM018 DIM019 IOB 450 IOB 480 IOB 550 IOB 580 IOB 451 IOB 481 IOB 551 IOB 581 DO2 DO3 DO4 DO6 DO7 DO8 DO9 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI1 GD DI2 AO1 GD 107 [4.2] AO2 SCAE 1 : 2 40 60 80 mm DI5 GD DI6 DI7 GD DI8 DI9 GD DI10 DI11 GD DI12 GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD UI8 DI16 GD DI DI14 GD DI 107 [4.2]
DIM020 DIM021 IOB 452 IOB 482 IOB 552 IOB 582 IOB 453 IOB 483 IOB 553 IOB 583 DO1 DO2 DO3 DO4 DO6 DO7 GD UI2 UI3 GD UI4 UI5 GD UI6 AO1 GD AO2 AO3 GD AO4 AO5 GD 107 [4.2] DO1 DO1 DO2 DO2 DO8 AO6 SCAE 1 : 2 40 60 80 mm DO3 DO3 DO4 DO4 1 1 1 1 GD UI2 UI3 GD UI4 UI5 GD UI6 AO1 GD AO2 AO3 GD AO4 AO5 GD 107 [4.2] AO6 Functions WEB, STUDIO ROC IX IOB Gateways VIS, -STAT DAI Routers, IC Interfaces Accessories buildings under control
Accessories Interfaces Routers, IC DAI VIS, -STAT Gateways IOB IX ROC WEB, STUDIO Functions DIM022 IOB 454 IOB 484 IOB 554 IOB 584 94 DO1 DO2 DO3 DO4 DO6 DO7 OW PRESSURE HIGH GD UI2 UI3 GD UI4 UI5 GD UI6 UI7 GD C AO1 GD AO2 AO3 GD AO4 107 [4.2] SCAE 1 : 2 40 60 80 mm