Connex Vital Signs Monitor 1.7 to 2.2 Upgrades

Similar documents
Connex Spot Monitor (CSM) 1.x Software Version

Date: SAP DIR #: PMP Host version and earlier Welch Allyn Service Tool version X and earlier

Customer Service Bulletin

Welch Allyn Service Dashboard. Administrator guide

Date: SAP DIR #: Subject. CSB Clearing CVSM/CIWS NIBP EEPROM Error

confident capable comfort

Connex Device Integration Suite (CDIS) Network Connectivity Engine (NCE) software

Cardiac Monitoring Catalog USA

GettyImages jpg. Vital Sync Virtual Patient Monitoring Platform. User Guide

LPAdjustableBases.com. Prodigy CE. app instructions

The Smart Prime 6 Frequently Asked Questions. The Smart Prime 6 handset

Welch Allyn Connex Vital Signs Monitor 6000 Series. Service manual

FIELD GUIDE for dbadge2 Personal Noise Dosimeter

IMS Client Operation Guide Version V1.1 Date

ios Accessibility feature: Guided Access

Acuity LT Hardwired Central Monitoring System

SWITS User Manual. Accessing SWITS. This document focuses on the elements required to Access SWITS. Total Pages: 5

INSITES CONNECT ADMINISTRATION GUIDE. Version 1.4.3

Date and Time Change FAQs

EASI MP-X Series. User Manual EASI MPR. Workstation. MPR Workstation user manual, , rev003

Mindray North America. Patient Monitoring FAQ s

ADT EPR Provincial Manual 10 Getting Started in EPR Gateway Version Revision Date Course Length

Student User Manual December 2017

Hardware and Components: Philips Monitors in Critical Care

Work Smart: Windows 7 New Features

Quick Guide 0005C: Installing and Using e-bridge (Secure Messaging) on a Windows PC

Date: SAP DIR #: Subject: CSB PLFM Radio Ver Upgrade. CVSM Host version or earlier

QUICK REFERENCE GUIDE

my i-limb App: Quick Reference Guide for i-limb quantum

VISTA DESKTOP. The following table explains the various features of the Windows Vista desktop.

Content. Welcome... 5 Getting Started... 5 Initial setup... 5 Setting a SIM card... 5 Locking and unlocking the screen... 7

Brivis Touch. Owner s Manual

Outdoor User Manual. ios Application Android Application PC Setup

FIELD GUIDE for dbadge2 Personal Noise Dosimeter

The Qube compact monitor delivers both simplicity and style. VERSATILE INTRODUCING QUBE

QUICK REFERENCE GUIDE

FAQ for KULT Basic. Connections. Settings. Calls. Apps. Media

Copyright

Frequently Asked Questions

Mate2. Quick Start Guide

Welch Allyn Connex Vital Signs Monitor 6000 Series

DSS User Guide. End User Guide. - i -

Training Booking System User Guide Contents:

Welcome to Maestro. Your Quick Guide for Getting Started and Using Key Features. Maestro. Save time. Easily communicate with colleagues

User Guide. BlackBerry 8700 Smartphone

Mirasys NVR. User s Guide

8 Processing Applications for Permanent Changes of Station (PCS) Transactions

PHYSICIAN S OFFICE STAFF Instructions for Paragon s WebStation for Physicians

CME E-quotes Wireless Application for Android Welcome

Your phone at a glance

Flex Supplier Portal How to use Flex Supplier Portal

Keylines DO NOT print 4-Color Process. with TIPS CARD. See System Operating Manual for complete instructions including warnings and cautions.

Hand-Held Inspection Device. Quick Start User Guide

Set-Top Box Guide. Got Questions? Get Answers Online: Or Call Us At:

User Manual. Version 1.1. Page. Nicole Durham 7/21/16

DART SVP. Software Manual For Web Based User Interface And For Apple ipod touch User Interface. Software Version 3.0.x ipod Application Version 1.

MCS-TOUCHSCREEN Auto Disk Clean up

GV-Access for ios and Android Mobile Devices

OptionPower 3.2. for Office 2007 STARTUP GUIDE. Interactive Audience Response Systems

Welcome Getting Started Initial setup Locking and unlocking the screen Screen and Display The home screen...

Introduction to the SAM Student Guide 4. How to Use SAM 5. Logging in the First Time as a Pre-registered Student 5 Profile Information 7

This guide describes features that are common to most models. Some features may not be available on your tablet.

GAMMA instabus Application Program Description. July CO Colour Touch-Panel

Creating and Using a Database in Access 2007

itrail Convoy (Global) User s Manual

Document Number: /4/2012

Major League Baseball Club Accreditation System

EV1000 Clinical Platform Software Version 1.9 Quick Reference Guide

X SeriesTM. Xtremely. Small, Light, and Powerful

The MalariaCare Toolkit. Tools for maintaining high-quality malaria case management services

2015 Optima Healthcare Solutions Page 2

Blue Meeting Room

If you are currently using a beta version of EPIC that is prior to 4.56 then you need to upgrade to version 5.00.

Site Coordinator User Guide

CPN Training Materials

Operating Instructions. Panorama. Web Viewer

Quantum 3.2 Software. User Manual

SAVANT PRO 8 APP AT A GLANCE

BookSense User Manual

Captivate your audience by integrating Operator Assi sted audio conferencing with the cutting edge Adobe Connect online collaboration solution.

Interaction Feedback

GETTING STARTED. Link Controller. Remote

Microsoft Windows 7 is an operating system program that controls:

Veris Sensors App. Quick Start Guide Pressure Monitoring. For Use with Differential Pressure / Air Velocity Transducers. Introduction.

TriCounty Telecom IPTV User s Guide


GET STARTED. ALL YOU NEED TO KNOW TO GET GOING.

LEGAL NOTICE INVITATION TO SUBMIT BIDS

Using MDC Manager to Manage Power Settings

Safety Assistance Watch

Getting Started. Microsoft QUICK Source 7

980 HDMI 2.0 Protocol Analyzer UHDA Source Compliance Test

User Guide. 3CX Audio Scheduler. Version

InForm for Primary Investigators Performing esignature Only (v4.6) Narration

Welch Allyn Connex Vital Signs Monitor 6000 Series

PATIENT SAFETY INCIDENT REPORTING AND LEARNING. Training manual for web-based information system

Manual Version: V1.15. Video Management Software Guard Station User Manual

HSIP2 User Manual. ios Application Android Application PC Setup

HSIP2 User Manual. ios Application Android Application PC Setup

Lenovo TAB A User Guide V1.0. Please read the safety precautions and important notes in the supplied manual before use.

Transcription:

Connex Vital Signs Monitor 1.7 to 2.2 Upgrades Clinical Inservice Presentation MC12690 1

Welcome! Thank you for choosing Welch Allyn! Objectives: 1. Identify User Interface (UI) changes between CVSM 1.7 and CVSM 2.2 2. Identify additional applicable parameters and features added to your CVSM device MC12690 2

Table of Contents & Summary of Changes Updates to Home Screen, menus and NIBP features Power off Two additional NIBP programs Lock Display Icon Manual parameter entry & clear function Custom Modifier entry Custom Scoring (EWS) entry Combine Manual & Modifier tabs Placement of Profile Configuration in Advanced Settings & Profile Change Continuous Monitoring option Pause Monitoring option Addition of etco 2, RRa, or EarlySense (optional) Patient Rest Mode (Connex Central Station required) MC12690 3

Power Off on CVSM 2.2 1. Press the Power On button located on the side of the device 2. The onscreen Power Down dialog appears 3. Select the desired function from the list Power Down Sleep Cancel Power Down may also still be accomplished by touching the battery icon in the top right corner of the Home Screen and choosing POWER DOWN, as with CVSM 1.7 devices. MC12690 4

Two additional NIBP Programs on CVSM 2.2 Two additional blood pressure Programs have been added. A Program is now entered in Interval (minutes) and Frequency (number of occurrences). 1. Enter the Interval by selecting a value from the dropdown menu. 2. Enter the Frequency by typing in the desired number of occurrences. Example: Q15 X 4 MC12690 5

Lock Display Icon on CVSM 2.2 The display lock prevents clinician input, which can be useful during cleaning the display. To lock the display: 1. Touch the Settings tab 2. Touch the Device tab 3. Touch Lock Display Now To unlock the display, touch the icon. MC12690 6

Manual Parameter Entry and Clear Function on CVSM 2.2 All automated parameters can now be manually entered or cleared All readings are marked with Source: Manual on the home screen, and are noted with an * in the review tab next to the value To manually enter or clear a value: 1. Press and hold the desired parameter frame 2. Type the desired value in the keypad 3. Press OK 4. To clear a value, touch the backspace button and press OK MC12690 7

Custom Modifier Entry on CVSM2.2 Up to 20 custom modifiers can be entered at the device Custom Modifiers will be determined by your facility Connex required The fields can be entered as any of the following: -Free text -Drop down list -Integer or Decimal entry To enter Custom Modifiers: 1. Touch the Custom Modifier box on the Home screen 2. The Manual tab appears displaying all available fields 3. Select an entry from a dropdown list or touch in a field to enter a value using the keypad 4. Press OK to confirm the entries MC12690 8

Custom Scoring Entry on CVSM 2.2 Provides a facility the capability to calculate Early Warning Scores at the device Scoring system is determined by facility Available only in Spot Check/ Intervals Monitoring. Scoring summary will alert staff if a further clinician notification is required MC12690 9

Manual and Modifiers Tab On CVSM 1.7 Devices Manual Parameters -From the Home tab, touch the Manual parameters frame. -Touch the up/down arrow keys or the keypad to adjust the parameters. -Touch OK to confirm settings and return to the Home tab. For Modifiers -Touch the Patients tab. -Touch the Modifiers tab. -Enter desired settings. -Touch OK to accept the changes, or touch Clear to delete all entries. MC12690 10

Manual and Modifiers Tab On CVSM 2.2 Devices The Manual and Modifier tabs have now been combined to eliminate an additional key press. User can now shortcut to the Manual tab by pressing the manual field on the home screen. Once this tab is selected, all Manual and Modifier options will be available for selection. MC12690 11

Changes to Patient Profile Configuration CVSM 1.7 to 2.2 User Interface for Patient Profile Changes Triage, Spot, and Monitor were the three available profiles by default. Profile name change was done by selecting the settings tab and choosing profiles. The user would then delete and type the name they desired for the profile. To change the default profile, the user selects the profile of choice and would then press save as default from the device tab. The available profiles by default are now: Triage Spot Intervals Monitoring (Formerly Monitor on 1.7) Continuous Users must now go into Advanced Settings to set the default profile, choose available profiles and rename profiles. The user can still navigate to the profiles as with 1.7; however, the editing and changing of the default profile must be done in Advanced settings. To change profiles in 2.2, now the user simply has to press the profile shown at the top right of the screen. (see next slide) MC12690 12

Profile Change for CVSM 2.2 1. Touch the current Profile displayed in the status bar. 2. Select the desired Profile from the list provided. -Continuous Monitoring -Intervals Monitoring -Spot Check -Triage 3. Touch the Home tab to return to the Home screen. MC12690 13

Continuous Monitoring on CVSM 2.2 CVSM 2.2 only features The CVSM 2.2 offers a new profile, Continuous This profile allows for the continuous collection of data and can incorporate any one of these three new technologies: Continuous capnography (Microstream etco2) Acoustic Respiration (Masimo RRa) Contact-free monitoring (EarlySense ) for PR, RR and patient movement, or contact-free monitoring (EarlySense Safety) for patient movement only MC12690 14

Continuous Monitoring on CVSM 2.2 CVSM 2.2 only features Continuous Mode will allow for the continuous collection of data for an individual patient; therefore, the review screen will change. Data in review will be for an individual patient only. The trend period options will change as well. Continuous mode will give the team member the ability to Pause monitoring. User can press the Pause button to suspend continuous monitoring for a specified period of time, while maintaining patient information on the device. CVSM can be paused for up to 4 hours. Patient monitoring will automatically be resumed once the countdown timer expires. NOTE: If EtCO2, RRa, or EarlySense are purchased, training will be provided onsite for the facility. The next two slides illustrate the Continuous Review Screen and Pause Monitoring features. MC12690 15

Review Screen on CVSM 2.2 in Continuous Profile Data in review will be for an individual patient only. The trend period options will change as well MC12690 16

Pause Monitoring on CVSM 2.2 MC12690 17

Patient Rest Mode on CSVM 2.2 CVSM 2.2 only feature Patient Rest Mode is available for those customers using the Welch Allyn Connex Clinical Surveillance System While in Patient Rest Mode, the CVSM s audio is turned off, and the screen is dimmed. Visual indication of alarms remains at the device, and audible alarms remain at the Central Station. The user will have the ability to turn Patient Rest Mode on individually at a single device or for all connected devices at the central station. MC12690 18

Patient Rest Mode If devices are connected to a Central Station, you may turn on patient rest mode Allows disabling of audible alarms at the bedside, but keeps alarms on at CS If connectivity is lost from the CS, alarms will revert to previous audio state To use: Touch alarms Choose Patient Rest Mode On MC12690 19

Resources Thank you for choosing Welch Allyn Customer Care: 1-800-535-6663 Website: www.welchallyn.com MC12690 20