SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

Similar documents
SIY. Features. PC-Programmable Signal Isolator/Converter

SDY. PC-Programmable Signal Isolator/Converter with Display

HIT/HIX HART Isolator

SFY Functional Safety Frequency-to-DC Transmitter with Display

ECT Signal Isolator/Converter

FDY. Features Exceptional accuracy and long-term stability. Typical accuracy is ±0.025% of span with up to 5 years between scheduled calibrations.

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

STA SIL 2 and SIL 3 Capable Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms

No J September PC-Programmable Signal Isolator/Converter SIY

SYI TRY & TRX TRX & TRY. User s Manual. PC-Programmable Temperature Transmitters. Isolated (TRY) & Non-Isolated (TRX)

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

Intrinsically Safe Barriers

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

TIY TIY. Thermocouple Transmitter. Programmable Isolated. Programmable Isolated Thermocouple Transmitter. July E

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

M-series Intrinsically Safe I/O

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

NCS MIM. with MODBUS Interface. NET Concentrator System. September A. with MODBUS Interface

4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

SYI TDY. User s Manual. PC-Programmable Temperature Transmitter with Display. Demand Moore Reliability. No H November 2017

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

HES. Description. Industrial Internet of Things - HART Over Ethernet

FLEX Ex Spring Clamp Terminal Base

General Specifications

General Specifications

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

SITOP in the SIMATIC Design

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Fisher i2p-100 Electro-Pneumatic Transducer

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Isolated Process Current Input with Loop Power 7B35

TS Series. Description

PHOENIX CONTACT - 12/2007

TEPI11 P/I signal converter

MODEL 9250 Preliminary data sheet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Series 3730 Electropneumatic Positioner Type

SCADAPack Modbus multivariable transmitter

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Operating Instructions

User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PI-EX-ME-2NAM/COC-24VDC

General Specifications

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

APPLICATION GUIDE. Interface Modules IM Series.

Operating Instructions

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

/8 DIN Universal Process Indicator

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

microncs Description Features MODBUS RTU Master and Distributed I/O System

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

PI-EX-ME-2NAM/COC-120VAC

Series 3730 Type Electropneumatic Positioner

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

itemp TMT180 Technical information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

General Specifications

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

INSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS 1. GENERAL DESCRIPTION PAGE 1

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

DeltaV SIS TMConditioning Components

Inform IT Single Pen Circular Chart Recorder

DeltaV SIS Conditioning Components

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

BMXAMI0410 analog input module M340-4 inputs - high speed

DC561, digital input/output module,

3420 Fieldbus Interface Module (FIM) Contents

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Thermocouple Input Module Product Specifications and Installation Data

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Proximity Transducers, Seismic Sensors and Accessories

Type i2p-100 Electro-Pneumatic Transducer

Thermo Scientific CM515 and HME900 Density Converter Electronics

8mm, 5mm Proximity Probe TM0180 and TM0105 Systems

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

AI561 Analog Input Module

VariTrans P The Problem The variety of tasks results in a large number of different devices.

4110 HART Level Encoder

M-series Traditional I/O

DC562, digital input/output module,

VALVE ACCESSORIES & CONTROLS V100 POSITIONER VAC V100 SERIES POSITIONER SIMPLE DURABLE RELIABLE

Transcription:

September 2003 New Features! Data Sheet 2.55 Description Moore Industries Signal Isolator/Converter combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy, and ease of use. The highly versatile programs to accept a wide range of current or voltage inputs. It outputs an isolated, proportional, signal. As a flexible analog/digital hybrid, this 2-wire (loop-powered) transmitter programs in seconds to handle a wide range of important signal interface applications: Isolate Signals to stop erratic process measurements caused by ground loops. Convert Signals so field instruments can interface directly with an indicator, recorder, DCS, PLC, or PC-based SCADA system. Divert Signals so the output from one transmitter can be sent to two separate locations. Protect Equipment and Signals by eliminating common electrical paths. Boost Signals so that more instruments can be added to an overburdened loop. Solve Bucking Power Supplies by stopping a conflict caused by a 4-wire transmitter and a DCS both trying to power the same process loop. Figure 1. Compact yet powerful, this 2-wire signal interface features programmable inputs with a completely isolated output. Current 0-20mA 0-50mA 10-50mA Special Ranges 1 2 3 4 COM Voltage 0-1Vdc 0-5Vdc +PS PS 1-5Vdc 0-10Vdc Special Ranges 2-Wire (Loop-Powered) * All product names are trademarks of their respective companies. New Available in rail-mount DIN-style and head-mount hockey-puck housings, these precision instruments install in a high-density cabinet or in harsh field conditions. Features Wide range of signal input choices. There s no need to specify and stock fixed-range instruments as spares. The handles the majority of current/ voltage interface applications you are likely to encounter. Input/output. The delivers superior protection against the harmful effects of ground loops and other plant noise. Fast measurement cycle. Delivering an output update up to 8 times per second, you ll get analog speed combined with digital versatility. RFI/EMI protection. The is resistant to the harmful, unpredictable effects of radio frequency and electromagnetic interference. Enhanced configuration software. From a single screen, you can set all the applicationspecific parameters. New features allow you to: trim input sensor readings, customize input linearization curves, program output damping, and calibrate other loop instruments-all from a single screen! Certifications Check the listing and the housing information on Page 3 for full certification details. 2003 Moore Industries-International, Inc. 235-710-05C

Specifications Performance Accuracy: ±0.08% of span (includes input accuracy, output accuracy, and the combined effects of linearity, hysteresis, repeatability, and adjustment resolution) Minimum Input Span: Current, 1mA; Voltage, 250mV Isolation: HPP housing, 1500Vrms input to output to case; DIN housing, 500Vrms input to output to case Measurement Cycle: Output updates 8 times per second Output Response: 256msec, maximum (128msec typical) for output to reach full scale in response to a 10-90% step change on input Input Impedance: Voltage, 1Mohm; Current, 20ohms Ripple: 10mV peak-to-peak maximum (measured across 250ohm resistor) Load Effect (current outputs): Negligible within specified load limits Performance (continued) Ambient Conditions Power Supply Effect: 0.002% of span per 1V change Over-Voltage Protection: 48V, maximum on output; 48V reverse polarity protection on output Maximum Input Overrange: Current: 100mA maximum continuous; Voltage on Current Input: ±5Vdc peak; Voltage: 18Vdc Load Capability: Supply Voltage 10V = Ohms 21.4mA Output Current Limiting: 3.8mA (low) and 21.4mA (high) Operating Range: 40 C to +85 C ( 40 F to +185 F) Storage Range: 40 C to +85 C ( 40 F to +185 F) Effect of Ambient Temperature on Accuracy: ±0.015% of span/ C Relative Humidity: 0-95%, non-condensing Ambient Conditions (continued) Adjustments Weight RFI/EMI Immunity: 20V/m @ 20-1000MHz, when tested according to SAMA standard 33.1 (10V/m @ 80-1000MHz, 1kHz AM, when tested according to IEC 1000-4-3-1995) Common Mode Rejection: 100dB, minimum, @ 50/60Hz Normal Mode Rejection: 60dB, typical, @ 1V peakto-peak, 50/60Hz The choice of a current or a voltage input is selected via the input terminals; all other settings are made using Windows-based configuration software HPP-Style Housing: 65 g (2.3 oz) DIN-Style Housing: 184 g (6.5 oz) LH1-Style Housing: Polyester Cover: 283.5 g (10 oz.) Metal Cover: 468 g (16.5 oz.) Stop Ground Loop Noise! A difference in potential between a grounded transmitter and a grounded receiving device on the same loop may result in unpredictable ground loop problems, which can lead to signal drift. Use the to break the galvanic path between a field transmitter and an indicator, recorder, DCS, PLC, or PC-based SCADA system. This stops the harmful effects of ground loops, motor noise, and other electrical interferences. NON- ISOLATED 2-WIRE PS + PS + Non- +PS +PS + + RECEIVER Everything you need is included... Each order comes with one copy of our Configuration Software on a 3½-inch floppy disk (Windows 3.1, 95, 98, NT, 2000 and XP Compatible). To order additional copies, specify Moore Industries part number: 235-75120-01. A Configuration Cable is required to use the PC to configure the. To order an unisolated cable for use in the shop using a grounded PC, specify Moore Industries part number 803-040-26. If you plan to configure the in the field or in areas with high ground potentials, specify part number 803-039-26 for a cable equipped with its own selfpowered, input-to-output circuit. Ground POWER SUPPLY POWER SUPPLY Ground Page 2 Specifications subject to change without notice. Printed in the U.S.A.

Ordering Information Unit Input Output Power Options Housing PC- Programmable Isolator/ Converter PRG Programmable with supplied Configuration Software and front panel connection terminals for: CURRENT (into 20ohms): Any range from 2.5mA to 55mA including: 0-20mA 0-50mA 10-50mA (recommended minimum span, 1mA) VOLTAGE (into 1Mohm): Any range from 0.5 to 11V including: 0-5Vdc 1-5Vdc 0-10Vdc (recommended minimum span, 250mV) Programmable output span between 4mA minimum and 20mA maximum into 650ohms with 24Vdc power supply 10-42DC 10-30DC Required for ISC, ISE, ISF, and NE options -ISC CSA approved IS (HPP) -ISE LCIE- ATEX approved IS (HPP) -ISF FM approved IS (HPP) -NE Type N w/lh (HPP) DIN DIN-style aluminum housing mounts on 32mm G-type (EN50035) and 35mm Top Hat (EN50022) rails HPP Hockey-puck housing for mounting in standard connection heads LH1NS Connection head (FM approved, NEMA 4X, IP66) with two entry ports: ½-inch NPT cable and process black PBT polyester cover LH1MS Connection head (FM approved, NEMA 4X, IP66) with two entry ports: M20 cable and ½-inch NPT process black PBT polyester cover LH1CS Connection head with two entry ports: M20 cable and G½ (BSP) process black PBT polyester cover LH1NX Connection head with ½NPT entry and mounting plate for customer's air duct opening black PBT polyester cover LH2NS Explosion-proof connection head (FM approved, Class I, Div 1, Groups A*,B,C,D; Class II, Groups E,F,G; Class III) with two entry ports: ½-inch NPT cable and process black metal cover LH2MS Explosion-proof connection head (FM approved, Class I, Div 1, Groups A*,B,C,D; Class II, Groups E,F,G; Class III) with two entry ports: M20 cable and ½-inch NPT process black metal cover CH6 Plastic connection head CH17 CSA & UL approved explosion-proof housing for use in Class I, Div 1, Groups A,B,C,D; Class II, Groups E,F,G; Class III NOTE: Add E suffix to any LH2 housing to obtain ATEX Flame-Proof certification. The 2-inch pipe mounting hardware is included. (e.g., LH2NSE) Add P suffix to any LH housing for 2-inch pipe mounting hardware. (e.g., LH1NSP) * For Group A (only) all conduits must be sealed within 18 inches. LH2 Explosion-proof certification carries 60 C (140 F) max ambient temperature restriction. Other connection heads, cabinets, and enclosures also available. Ask your Interface Solutions Expert for details. When ordering, specify: Unit / Input / Output / Power / Options [Housing] Model number example: / PRG / 4-20MA / 10-42DC [DIN] Certifications Factory Mutual Approvals: Intrinsically Safe & Non-Incendive [HPP]: Class I, II, III, Division 1, Groups A, B, C, D, E, F, G Class I, Division 2, Groups A, B, C, D Suitable for use in: Class II, Division 2, Groups F and G Class III, Division 2 Temperature Code: T6@60 C Max. Op. Ambient Explosion/Dust Ignition-Proof [HPP in LH2]: Class I, Division 1, Groups A*, B, C, D Class II and III, Division 1, Groups E, F, G T6@60 C Maximum Operating Ambient Environmental Protection: NEMA 4X, IP66 Canadian Standards Association (CSA) General (Ordinary) Location [DIN/HPP] Intrinsically Safe & Non-Incendive [HPP]: Class I, Divisions 1 and 2, Groups A, B, C, D CENELEC/ATEX 94/9/EC Directive Approvals: LCIE - Intrinsically Safe [HPP] II 2G EEx ia IIC T6@60 C ISSeP - Flame-Proof [HPP in LH2] II 2GD EEx d IIC T6, IP66 Type N Inherent [LH] II 3G EEx na II T6 CE Conformant EMC Directive 89/336/EEC EN 61326 * For Group A only, all conduits must be sealed within 18 inches 60 C (140 F) Maximum Operating Ambient Temperature Page 3

Convert Signals The takes one process signal type (such as 1-5V) and converts it to a standard, isolated. This allows devices like transmitters and transducers to interface directly with an indicator, recorder, DCS, PLC, or PC-based SCADA system. 4-WIRE 1-5Vdc POWER SUPPLY RECEIVER Divert and Protect Signals Using the, you can send the output from one transmitter to a second location, protect expensive monitoring/control equipment by eliminating common electrical paths, or create a buffer between devices to allow interruption of one system without impacting the other. ISOLATED 2-WIRE Loop PLC DCS Loop Boost Signals If you need to add another instrument to an overloaded loop, use the. It features a high drive capability of 650ohms (with a 24V power supply) and an input impedance of just 20ohms. 4-WIRE (into 700ohms Maximum) INTEGRATOR (250ohms) PID (250ohms) (20ohms) 24V into 650ohms RECORDER (250ohms) Solve Bucking Power Supplies When two devices (such as a 4-wire transmitter and a DCS) are trying to source power to a loop, the result is a non-functioning loop. When neither of the devices can be eliminated, the solution is the. It can operate with powered inputs from both sides, thus restoring normal operations to the loop. 4-WIRE 24V 24V DCS Page 4

One Window. One Minute. One Setup. New Software! New Features! Figure 2. From a single software window, you can program the in one minute or less Configuring the is as simple as point-and-click. All you need is a PC running Windows (v3.1, 95, 98, or NT), our Configuration Software (one copy supplied free with each order), and a configuration cable. In minutes, you can begin configuring the following transmitter parameters: Input type and range (zero and full scale) Output range (, zero and full scale) Noise rejection (50Hz or 60Hz) Direct or reverse output Over or under input range detection Custom instrument tag and serial number Custom input linearization Custom input trimming to actual sensors Fixed output with an easy loop test Damping time for erratic signal compensation (0-20.032 seconds) Custom Linearization Tables Unusual inputs are not a problem for the. Not when it is so easy to build a custom 85-point linearization table with the Configuration Program s straightforward interface. Output Damping If your sensor is prone to step increases and decreases, use the to lessen the impact on your process. You can program a damping value from 0 to 20.032 seconds, averaging out sensor fluctuations over the time period setting, and lessening the impact of step changes. On-Screen Setup Confirmation Once programmed, the operating parameters you have selected are constantly displayed in the configuration window. Configuration Alerts Data fields on the configuration window provide alert messages (such as Zero or Full Scale Outside of Conformance Range ) to let you know when you are making a nonstandard or ill-advised selection. Store and Print Files After you ve created a configuration file, it can be downloaded to mulitple s, printed out as a hardcopy, or named and stored (on a PC hard drive or disk). Reverse Output Setting Zero Scale Input numerically above Full Scale Input will result in the transmitter s output going up when the input goes down, and vice-versa. When you have chosen this operation, the Output portion of the configuration screen changes to read Reverse Output. Digital Output Trimming A sophisticated yet simple-to-implement software feature allows you to adjust the s output to compensate for inaccuracies in your readout equipment. The Zero Scale Output can be adjusted between 3.797 and 17.400mA. The Full Scale Output adjusts between 7.798 and 21.401mA. Context-Sensitive HELP System Just point to the area on the Configuration Screen where you are encountering difficulty, and an explanation appears on the bottom of the screen. Page 5

Figure 3. Installation Dimensions. TOP BOTTOM SIDE 51.8 mm (2.04 in) 25.4 mm (1.0 in) 8.8 mm (0.35 in) 16 mm (0.63 in) 10 mm (0.39 in) 5.5 mm (0.22 in) 5.5 mm (0.22 in) 8.8 mm (0.35 in) +PS PS Hockey-Puck (HPP) Housing 48.7 mm (1.92 in) 1 29.7 mm (1.16 in) 2 3 4 26.7 mm (1.05 in) C L 33 mm (1.3 in) 7 mm (0.28 in) 6 mm (0.24 in) 7 mm (0.28 in) 4 X40 0.125 in depth 2 PLACES 33 mm (1.3 in) 138.2 mm (5.44 in) WHEN INSTALLED 133.4 mm (5.25 in) WHEN INSTALLED 1 2 3 4 43 mm (1.69 in) DIN-Style (DIN) Rail-Mount Housing COM 80 mm (3.15 in) +PS PS Table 1. Terminal Designations. 25.4 mm (1.0 in) Input Input Output Type Terminals Terminals Terminal Number 1 2 3 4 Left to Right Current Inputs +I -I +PS -PS Voltage Inputs +V -V +PS -PS 109.7 mm (4.32 in) 112.7 mm (4.44 in) Factory Configuration Available We can deliver your Isolator/Converters preconfigured to your specifications and ready to install. You ll still receive a free copy of our software with your order so that you can reconfigure your if your needs change. Consult your Moore Industries Sales Representative for details. The Interface Solution Experts www.miinet.com United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China sales@mooreind.sh.cn Tel: 86-21-62481120 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 Page 6