Est Active Power Factor Regulator. 100kVA kVA

Similar documents
Est Active Power Factor Regulator APR-L 100kVA kVA APR-H 1-10MVA

Est Static Transfer Switches STSt A STSi A

Est Constant Current Regulator MC2 3kW 30kW

Est Uninterruptible Power Supplies

Est Constant Current Regulator MC4 3kW 30kW

Est FlexiPower Maxi UPS FPX Maxi kVA

Est ComPower Mini. Compact UPS kva

Modular UPS S KVA

Est FlexiPower Ultra UPS FPX Ultra kVA

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Est FlexiPower Maxi. Modular UPS kw

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

MEGADRIVE-LCI. Medium voltage AC drive for control and soft starting of large synchronous motors

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

MP7. Uninterruptible Power Supply

Hitec QPS product range

UNITROL 5000 Excitation Systems for Medium and Large Synchronous Machines

Liebert GXT MT kva

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Socomec Netys PR RT U P S TOWER / RACK MOUNT

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.

Quantum Chargers Enhanced AC Line Transient Immunity

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Uninterruptible Power Systems

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Specification Voltage Limiting Device

LPI SST Surge Filters

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Tel: AC Power for Business-Critical Continuity TM

7011A Series Single-Phase

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

DC Substations / Supply Program

T300MVi MEDIUM VOLTAGE DRIVES

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Medium Voltage Metal-Enclosed Harmonic Filter Systems

FUSELESS ists C,H,K & G

MAJOR VA Power Inverter

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

JUNXY Series DC Load Banks

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

LP 33 Series UPS. Digital Energy. GE Digital Energy

Medium Voltage Metal-Enclosed Power Capacitor Banks

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Technical Data Sheet Medium Current Power Surge Filters

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

AIR COOLED MODULAR RECTIFIER

RL Line/Load Reactors

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Cooper Controls Group. The power to drive industry

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire

Standard SureVolt Power Conditioner / Voltage Regulator

SMARTONLINE E3 UPS SYSTEMS

PRODUCT PRESENTATION PROTECT 1. April 2012 DATA&IT, SBU C-UPS, PM/SR

Air Cooled Medium Voltage AC Drives ALSPA VDM6000

RT12-240V/2.4kW Rectifier Specification

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

The Power of Modularity

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

StacoDVR-5 Digital Voltage Regulator Electromechanical three-phase kVA

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

LPI SG + SST Spark Gap Surge Filter

Intelligent On-Line UPS

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

LPI SG + SS480 Spark Gap Surge Filters

Industrial Facility Wide Protection

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

SVC static var compensator

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartOnline V 1kVA 700W On-Line Double-Conversion UPS, Tower, C14 inlet, DB9 Serial

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Product Specifications

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Variable Speed Drives

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Transcription:

Est.1968 Active Power Factor Regulator APR-L APR-H 100kVA - 1000kVA 1-10MVA

Concept New sophisticated technologies require a quality power supply and businesses today cannot afford to have their productivity diminished by even occasional outages. Poor harmonic distortion, including voltage notching, flicker and short-term sagging are no longer acceptable reasons for productivity down time. A poor power factor also results in unnecessary penalty electricity rates that add to the operating costs of business. Thycon Active Power Factor Regulators (APR) accurately and continuously regulate power factor and minimise harmonic distortion of the power supply to increase your business productivity. At higher power levels, APRs can also provide substantial energy saving and improved power network availability for existing power distribution infrastructure. Applications APRs are suitable for any power quality application where accurate power factor regulation, harmonic voltage distortion mitigation (including voltage notching, flicker and short term sagging) or maximisation of existing power distribution infrastructure is required. Beneficial applications of an APR include: minimised electricity supply bill penalty costs minimised disturbance notching and flicker caused by heavily switched loads increased power distribution network availability of up to 30% Minimised electricity supply bill penalty costs Active power factor correction using an APR is effective in minimising penalty power costs contributed by poor power factor of the supply. Correction of supply power factor from 0.7 to 1 can save up to 1c/kVArh. Minimised disturbance notching and flicker caused by heavily switched loads Rectifiers are notorious for supply harmonic distortion and notching effect caused by their heavy switching of currents. The waveforms shown on the following page highlight the quality of the mains supplying a 12- pulse rectifier with and without an APR. Increased power distribution network availability Increase in power distribution network availability is proportional to the voltage drop experienced by poor power factor on distribution lines over long distances. If a poor power factor of 0.7 causes a voltage drop of 20% over a 200 km of distribution line, an APR can be used to improve distribution capability of the power network by 20%. This can effectively: forestall the need to upgrade existing distribution power networks across the country reduce capital expenditure on new distribution power networks by allowing for the margin of growth as a result of using an APR APR features and benefits Thycon s Static Flywheel Technology continuous, accurate power factor regulation minimised harmonic distortion, notching, flicker and short term sagging microprocessor-based diagnostics and controls energy saving soft-start control robust technology eliminates contactor welding issues no moving parts fuseless design high efficiency high reliability long life cost effective low maintenance cost compact, modular construction indoor or outdoor enclosures Australian made 1

Power distribution APR on a heavily switched load Mains supply voltage and current without an AVR, THVD: 8%, THID: 11% Voltage Current 400 2.00 300 1.50 200 1.00 100 0.50 0V 0.00kA -100-0.50-200 -1.00-300 -1.50-400 -2.00 5ms/Div 5ms/Div Mains supply voltage and current with an AVR, THVD: 1%, THID: 6% 400 2.00 300 1.50 200 1.00 100 0.50 0V 0.00kA -400-0.50-300 -1.00-200 -1.50-100 -2.00 5ms/Div 5ms/Div Voltage Current 2

Wind farm generators Principle of operation Thycon APRs use a combination of thyristor current source inverter technology with fixed capacitor banks to provide a fully-controllable static VAr source. Insertion of the capacitor bank gives leading reactive compensation while insertion of the variable inductor gives lagging reactive compensation. The capacitor and inductor are varied to regulate the power factor at a user-defined point. The variable inductor is achieved by regulating inductive current through a thyristor converter. This mature, low-cost technology offers the best basis for rugged and extremely reliable power electronic conversion. The 12-pulse converter inherently reduces harmonic distortion to less than 1% without the use of additional filters. The APR has no moving parts and with the use of Thycon s Static Flywheel Technology has a high degree of stored energy to provide ride through capacity for short sags. By utilising SCR conversion to correct power factor it avoids the mechanical wear of continual step contactor operation that affects traditional power factor correction units. Its control of large kvar ratings is hence very effective. If a supply failure occurs, the APR disconnects from the supply. When the supply returns the APR waits for it to stabilise and then restarts. If a generator is connected then the APR can be held off-line if required. This mature, low cost technology offers... rugged and extremely reliable power electronic conversion. Installation and testing An APR offers modular design for quick and easy site installation. All that is required is the installation of power cables and control/monitoring cabling. The APR is tested comprehensively prior to delivery and needs minimal site commissioning. An APR can also be provided as a complete containerised assembly that can be placed in the harshest Australian conditions and easily relocated to other sites as required. Reliability and maintenance requirements Thycon has been supplying active power factor regulators for 40 years and has demonstrated their high reliability and low maintenance demands in critical applications for defence, telecommunications, computer centres and manufacturing. Transformers and power electronic converters can be forced or naturally cooled, which contributes to high reliability and low ongoing maintenance. The power components (capacitors, transformers, switchgear and instrument transformers) are all standard commercial products of proven reliability and long life expectancy. 3

2.5MVA power transformer installation Thycon APR maintenance requirements are dependent on environmental and application conditions. We accommodate customer requirements from basic to full warranty maintenance. Each maintenance plan ensures the equipment operates in top condition with maximum availability of engineers and parts at minimum cost to the customer. Qualified engineers perform the maintenance with the full back up and resources of Thycon. Training and support Training and support can be provided to on-site personnel to ensure that they are fully versed in the operation, maintenance and fault rectification of a Thycon APR. Control and monitoring Smart digital signal processing provides control and power factor regulation of an APR. The control is automatic, continuous and linear about the set-point selected by the user ensuring an inherently fast transient response. A soft-start mechanism at turnon and smooth regulation throughout the operating range eliminates the typical switching effects of traditional power factor regulation methods. APRs can be controlled and monitored from the unit itself and remotely via serial, TCP/IP, SCADA or DNP3. The system is totally automatic and does not require manual restarting for fault-initiated supply disturbances. Control and status An APR provides a simple control and status interface. Start and Stop push-buttons allow you to operate the equipment and to go on-line. Power Available and Power On LEDs indicate that the mains power is available and that the APR is on-line. A Cancel button is used as an audible silence alarm acknowledge. Monitoring The APR system monitor is a smart LCD panel featuring a simple and effective user interface that incorporates advanced diagnostic facilities enabling immediate access to: power monitoring - voltage / current / kw / kva / power factor / harmonic distortion operating status and alarms event history password protected user defined settings service control and test options The system monitor stores the last 200 system events in a non-volatile information buffer for fast, efficient fault diagnosis and status indication even after a re-start or a complete power outage. Low-level interface Operating status of the equipment to a remote monitoring system can be performed in the form of 8 standard voltage-free contacts. 4

3 phase 12 pulse 200kVA thyristor converter Additional features include the ability to notify your network server of alarm conditions and send emails to designated recipients. High-level interface Real-time performance monitoring of the APR is performed via serial, TCP/IP, SCADA or DNP3 connection. A basic hardcopy of operating events and data can be obtained by connecting a printer. An optional high-level interface via Modbus, SNMP or web html can be provided to those requiring additional display features for immediate performance monitoring and analysis. An additional feature is the ability to notify your network server of alarm conditions and send emails to designated recipients. APR data such as real-time waveforms, alarms and system events can be stored in solid state, nonvolatile memory holding up to 500 MBs of information. Connecting the APR to a PC using any of the available ports allows you to maintain a full history of the equipment over its lifetime. Options Remote monitoring Modem connection enables the APR to dial and notify Thycon or a remote user automatically whenever an alarm condition arises. Thycon s Service Centre automatically logs data, performs analysis and diagnostics and then alerts our 24-hour service staff if further intervention is required. All APR utilisation and incidents found or reported are logged and a full report is provided for each occurrence. The report highlights remedial actions, cautions and follow up recommendations. Alternatively, the remote user can interrogate the APR at will. Thycon power system monitor The APR monitor offers the user a web-based interactive diagnostic tool and database management system for continuous real-time monitoring of APR system utilisations, alarms, events and variables. The database management logs data to your PC s hard disk for future analysis and display. Expansion Future expansion and redundancy can be achieved by parallel connection of the APR modules. Each module can be isolated manually or automatically from the load bus without affecting availability of supply. Container modules An APR can be provided as a complete containerised assembly that can be placed in the harshest Australian conditions and easily relocated to other sites. Each module is self-contained enabling use in applications varying from city building rooftops to coastal oil rigs to outback mining stations. 5

Thycon APR advantages Design advantages Simple, reliable design Robust technology Static switch design with no moving parts Component rating Thyristor technology Fuseless design Surge protection Modular construction Environment Uncomplicated design facilitates high strength, durability and reliability. The power circuit uses simple, robust static switches to form a sine wave by line commutation control technology. This design contributes to significantly higher lifetime, reliability, MTBF and lower MTTR than traditional methods. Robust construction achieves reliable performance and long equipment life, as proven by 40 years of Thycon installations. This design eliminates the switching stresses, losses, interference, mechanical wear and tear and contactor welding suffered by traditional methods. Commercially available standard mains frequency thyristors are used as single devices up to 2.4kA. No series or parallel matching of components is required to achieve high power applications. Use of thyristors (SCRs) eliminates the need for special high-speed semiconductor fuses and crowbar arrangements and results in a simpler design with increased reliability. Thyristors have the highest power and fault tolerance of all semiconductor devices and can withstand faults of up to 10 times the current for 1000 times the period of transistor and IGBT switching technologies. No power fuses are required. Power components are liberally over-rated so that simple and reliable methods of circuit breaker protection can be used. This greatly reduces down time and eliminates the need for stock control of spare fuses. Built in surge protection increases the attenuation of over-voltages caused by distribution faults and lightning. Construction from standardised components and modules, results in a high mean time between failures (MTBF) and a low mean time to repair (MTTR). No special ventilation or air conditioning is required. The equipment is at home in computer rooms or in harsher environments without de-rating. Thycon equipment can be containerised and installed in the extremes of Australian environments. Performance advantages Soft-start control and active regulation Static transfer Thycon s Static Flywheel Technology Transient response Efficiency Parallel operation Smooth transfer on-line and accurate regulation through the operating range ensures seamless operation of the APR. Eliminates the typical crude and inaccurate step switching associated with traditional methods. Transfer to and from the load is fully automatic requiring no user checks or adjustments before it is initiated, thus removing the possibility of human error. The APR uses Thycon s proprietary Static Flywheel Technology to provide fast continuous regulation of power factor and harmonic distortion. This technology also allows the APR to store substantial reserve power for transient conditions and high crest factor loads. A fast dynamic response enables correction of transient step load changes within one power cycle period. System operates up to 99% efficiency resulting in low running costs and heat dissipation. Easy paralleling with similar systems during any stage of the APR lifetime means increased flexibility and permits future growth as required. 6

Technical specifications APR-L100-300 APR-L100 APR-L200 APR-L300 Reactive power rating 100kVAR at 415V 200kVAR at 415V 300kVAR at 415V 50Hz 50Hz 50Hz Rated voltage 415VAC 415VAC 415VAC Voltage operating range 415VAC ± 20% 415VAC ± 20% 415VAC ± 20% Supply unbalance withstand 2% continuous 2% continuous 2% continuous Temporary power frequency overvoltage 1.8pu for 3s 1.8pu for 3s 1.8pu for 3s Frequency - operating range 50Hz ± 5Hz 50Hz ± 5Hz 50Hz ± 5Hz Source impedance - operating range Not critical Not critical Not critical Current RMS 139A 277A 416A Overload current 150% 30s 30s 30s Overload current 120% 10 min. 10 min. 10 min. THVD* <1% <1% <1% Reactive compensation 100kVAR leading 200kVAR leading 300kVAR leading to 100kVAR lagging to 200kVAR lagging to 300kVAR lagging Regulation time constant Subcycle Subcycle Subcycle Insertion loss 2.5kW 5kW 7.5kW Audible noise level <65dB(A) <65dB(A) <65dB(A) Permissible ambient temp 0 to 45ºC 0 to 45ºC 0 to 45ºC Protection type IP20 IP20 IP20 Dimensions w x d x h (mm) 600 x 800 x 1200 600 x 1000 x 1800 600 x 1000 x 1800 Specifications are subject to change without notice *Subject to application 7

Technical specifications APR-L400-800 APR-L400 APR-L600 APR-L800 Reactive power rating 400kVAR at 415V 600kVAR at 415V 800kVAR at 415V 50Hz 50Hz 50Hz Rated voltage 415VAC 415VAC 415VAC Voltage operating range 415VAC ± 20% 415VAC ± 20% 415VAC ± 20% Supply unbalance withstand 2% continuous 2% continuous 2% continuous Temporary power frequency overvoltage 1.8pu for 3s 1.8pu for 3s 1.8pu for 3s Frequency - operating range 50Hz ± 5Hz 50Hz ± 5Hz 50Hz ± 5Hz Source impedance - operating range Not critical Not critical Not critical Current RMS 556A 833A 1111A Overload current 150% 30s 30s 30s Overload current 120% 10 min. 10 min. 10 min. THVD* <1% <1% <1% Reactive compensation 400kVAR leading 600kVAR leading 800kVAR leading to 400kVAR lagging to 600kVAR lagging to 800kVAR lagging Regulation time constant Subcycle Subcycle Subcycle Insertion loss 10kW 15kW 20kW Audible noise level <65dB(A) <65dB(A) <65dB(A) Permissible ambient temp 0 to 45ºC 0 to 45ºC 0 to 45ºC Protection type IP20 IP20 IP20 Dimensions w x d x h (mm) 600 x 1000 x 1800 1200 x 1000 x 1800 1200 x 1000 x 1800 Specifications are subject to change without notice *Subject to application 8

Technical specifications APR-H APR-H05M APR-H07M APR-H10M Reactive power rating 5MVAr at 22kV, 50Hz 7MVAr at 22kV, 50Hz 10MVAr at 22kV, 50Hz Rated voltage 22kV 22kV 22kV Maximum continuous voltage 26.4kV 26.4kV 26.4kV Voltage operating range 22kV ± 20% 22kV ± 20% 22kV ± 20% Supply unbalance withstand 2% continuous 2% continuous 2% continuous Temporary power frequency overvoltage 1.8pu for 3s 1.8pu for 3s 1.8pu for 3s Power frequency insulation withstand voltage 50kV for 1 min. 50kV for 1 min. 50kV for 1 min. Impulse withstand voltage 125kVp, 1/50_s 125kVp, 1/50_s 125kVp, 1/50_s (150kVp optional) (150kVp optional) (150kVp optional) Frequency - operating range 50Hz ± 5Hz 50Hz ± 5Hz 50Hz ± 5Hz Source impedance - operating range Not critical Not critical Not critical Current RMS 131A 183A 262A Short-time current withstand 10kA for 3s 10kA for 3s 10kA for 3s Overload current 150% 30s 30s 30s Overload current 120% 10 min. 10 min. 10 min. Auxiliary voltage supply 240/415V ac 240/415V ac 240/415V ac and 24-125V dc and 24-125V dc and 24-125V dc THVD* <1% <1% <1% Reactive compensation 5MVAr leading 7MVAr leading 10MVAr leading to 5MVAr lagging to 7MVAr lagging to 10MVAr lagging Regulation time constant Subcycle Subcycle Subcycle Insertion loss 125kW 175kW 250kW Audible noise level <70dB(A) <70dB(A) <70dB(A) Permissible ambient temp -5 to 45ºC -5 to 45ºC -5 to 45ºC Protection type IP54 IP54 IP54 Dimensions w x d x h (mm) 9000 x 2500 x 2500 10000 x 2500 x 2500 9000 x 5000 x 2500 Specifications are subject to change without notice *Subject to application 9

THYCON INDUSTRIAL PTY LTD 20 AUDREY AVE COBURG 3058 VIC AUSTRALIA PH 61 3 9319 9000 FAX 61 3 9319 9001 ABN 17 068 011 049 THYCON INDUSTRIAL PTY LTD 9 WRIGHTS RD DRUMMOYNE 2647 NSW AUSTRALIA PH 61 2 9911 6601 FAX 61 2 9911 6602 EMAIL info@thycon.com.au THYCON INDUSTRIAL PTY LTD 10 LISTER CRESENT AINSLIE 2602 ACT AUSTRALIA PH 61 2 6161 1548 FAX 61 2 6161 7789 WEB www.thycon.com.au THYCON INDUSTRIAL PTY LTD 11 PRESTON ST COMO 6152 WA AUSTRALIA PH 618 9367 0620 FAX 61 8 9457 2597 24-HOUR SERVICE 1800 670 700 Published by Thycon