November/December 2011

Similar documents
Virtualization and consolidation

Highly Efficient Power Protection for High Density Computing Applications

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Green IT and Green DC

Switch to Perfection

HPC Solutions in High Density Data Centers

Thermal management. Thermal management

APC InfraStruXure Solution Overview

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Building a power monitoring and management strategy Selecting the software and services needed to keep critical power systems continuously available

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Overcoming the Challenges of Server Virtualisation

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

The Evolving Data Center

The Green Imperative Power and cooling in the data center

ENCLOSURE HEAT DISSIPATION

Best-practice strategies for designing and deploying modular data centers

CyrusOne Case Study About CyrusOne

Data Center Infrastructure Management (DCIM) Demystified

84 kw, Tier 3, Direct Expansion, 937 ft 2

DC Energy, Efficiency Challenges

Data Center Infrastructure Management (D.C.I.M.)

APC by Schneider Electric Elite Data Centre Partner

Manage power your way

Next Generation Cooling

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

Liebert DCW CATALOGUE

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

MSYS 4480 AC Systems Winter 2015

Data Center Trends: How the Customer Drives Industry Advances and Design Development

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

DCIM Data Center Infrastructure Management Measurement is the first step

How to Increase Data Center Efficiency

The Energy. David L. Moss Dell Data Center Infrastructure

DATA CENTER COLOCATION BUILD VS. BUY

Total Modular Data Centre Solutions

Green Data Centers A Guideline

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis

Product Brochure Eaton 93PR UPS kw

White Paper: Data Center Capacity Management Provides New Business Opportunities & Efficiency at State-of-the-Art One Wilshire June 8, 2017

Data Center Lifecycle and Energy Efficiency

RF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

A Green Approach. Thermal

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

University of Florida Data Center at Eastside Campus: Key Facts

Careful What You Wish For: Poor Colocation Design Could Cost You. Thorough assessment of upfront costs to prevent future system failures

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Power and Cooling for Ultra-High Density Racks and Blade Servers

Reducing Data Center Cooling Costs through Airflow Containment

Google s Green Data Centers: Network POP Case Study

Los Anseles W Department of 5* Water & Power

Rethinking Datacenter Cooling

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

siemens.com/dcim We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Energy Action Plan 2015

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Building Management Solutions. for Data Centers and Mission Critical Facilities

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

DCIM Data Center Infrastructure Management

HPE Energy Efficiency Certification Service

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

Case study on Green Data Center. Reliance Jio Infocomm Limited

5.2 MW, Pod-based build, Chilled Water, ft 2

Optimiz Chilled January 25, 2013

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Catch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable

THE OFFICIAL TRADE JOURNAL OF BICSI

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER

Power & Cooling Considerations for Virtualized Environments

Comprehensive Data Center Energy Management Solutions

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Remodel. New server deployment time is reduced from weeks to minutes

Cooling Solutions & Considerations for High Performance Computers

Accelerate Your Enterprise Private Cloud Initiative

Facilities Design for High density Data Centers

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Company Builds Sustainable, Highly Efficient Headquarters Facility

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

EDX DC-3 environmental monitoring solution

Greening Terremark Data Centers

Measurement and Management Technologies (MMT)

Session 6: Data Center Energy Management Strategies

Transcription:

November/December 2011

Company is justifiably proud of its new facilities Helping companies plan, design, operate, and eventually refresh or repurpose their data centers more efficiently and effectively is a core part of Eaton Corporation s mission. So, too, is doing business in ecologically sustainable ways. Not surprisingly then, when Eaton embarked on Project BlueGrass, a strategic effort to construct next-generation data centers, it took its own advice, employing today s most sophisticated tools, techniques, and design William W. Blausey Jr. is senior vice president and chief information officer for Eaton Corporation, a $13.7 billion global diversified power management company. Blausey is responsible for the enterprise information technology strategy and execution. Blausey assumed his current position in January 2006 after serving as vice president, information technology, for Eaton s Fluid Power Group since 2001. Born and raised in Sweden, Lennart Jonsson completed his MS degree in electrical engineering from Chalmers University of Technology in 1974.In 2004 he was appointed as director of engineering at Eaton Power Quality Corporation, with the responsibility to develop and grow all power quality products globally. With a diverse and rich experience of 35 years in the power industry, Jonsson currently holds the title of executive vice president and chief technology officer for Eaton Corporation. BY BILL BLAUSEY AND LENNART JONSSON methods in a manner that carefully balanced business priorities with environmental responsibility. The result is a set of state-of-the-art computing facilities that will reliably support Eaton s IT needs for the next two decades while delivering a projected $23 million in energy savings along the way. ORGANIZATIONAL ALIGNMENT The first piece of advice is less about the technology itself and more about increasing ROI through the efficient and effective use of organizational alignment. At most companies, two departments split responsibility for the data center: IT, which typically reports up to the CIO; and facilities, which typically reports to the COO or vice president of corporate real estate. Changing the organizational structure so that both the IT and facilities departments report to the same executive helps to align everyone in the data center around common goals, metrics, and objectives. That, in turn, can drive greater efficiencies by ensuring that IT and facilities managers are equally motivated to improve performance and lower power bills. In order to maximize efficiencies and ensure the successful operation of Project BlueGrass facilities, Eaton created a new extension of the IT Enterprise Infrastructure Services Team, called the Mission Critical Facilities Team (MCF), consisting of resident engineers whose specialty consists of more than 10 years of electrical and mechanical experience in the data center space.

Eaton Takes Own Advice for New LEED Certified Data Centers We recognize that a specialized set of skills is required for our team to successfully operate, support, and manage the power and cooling infrastructure that is required by the IT equipment within our data center halls, said Rob Agar, vice president of enterprise infrastructure services at Eaton Corporation. By aligning the Mission Critical Facilities Team within the Enterprise Infrastructure Services Team, we feel the collaboration, direction, and integration of their activities is important to our success moving forward. As a result of this organizational structural change made three years ago at Eaton, these teams together own the facilities design and operation in Project BlueGrass, with decisions by one team directly affecting the responsibilities of the other group. INVESTING INTECHNOLOGY New electrical power management components are so much more efficient than their predecessors that they can quickly pay for themselves. Agar used only energy-efficient servers and switches, as well as the latest and more efficient power quality and distribution systems in the design and implementation of Project BlueGrass. Though such components will cost us a little more up front, said Agar, they will significantly reduce our energy bills and carbon footprint over the long term. In addition to upgrading uninterruptible power supply (UPS) hardware, you can also save money by modernizing your data center hardware. Deploying state-of-the-art, energy-efficient power distribution units (PDUs), such as the Eaton 400V epdu, can measurably lower your exposure to costly server outages as can upgrading to newer, more energy-efficient servers, said Agar. Figure 1. The Eaton 400V RPP works alongside Eaton 9395 UPS with Energy Saver System to extend the capabilities of its UPS technology, allowing users to run servers at 230V, while operating the UPS at 99 percent efficiency. MODULAR DESIGN PRINCIPLES Experts increasingly recommend taking a modular approach to power system design, in which capacity is deployed as it is needed and meets only the initial requirements at the outset. A modular power system offers both improved reliability, by building around multiple modular components instead of a single big one, and increases redundancy and greater flexibility due to smaller size and easier installation. These features make modular systems ideal for today s fast-paced data centers. To allow for future growth in Eaton s new data centers, Agar used modular power design principles in Project BlueGrass to support Eaton s needs for at least the next 10 to 15 years. While we initially will use only 30 percent of that capacity, we don t have to buy 15 years worth of anticipated power resources in advance, said Agar. This means that on day one, each site will contain two data halls of 10,000 square Figure 2. The lobby of Eaton s new facility feet at a power density of 90 watts per square foot. The ultimate build out of these two sites, however, is projected to be six data halls of 10,000 square feet each at a power density of 180 watts per square feet. ENTERPRISE MONITORING With web-based convergence solutions, organizations can use a single pane of glass to monitor their entire enterprise. Utilizing this secure holistic view, IT and facilities can increase server availability and optimize power usage. Convergence solutions correlate specific power circuits to

Eaton Takes Own Advice for New LEED Certified Data Centers building-related status information in one place, said Agar. In the event of an alarm, managers will be able to view alarms on a mobile device and have access to a complete, three-dimensional map of the data center that will provide real-time information about what the problem is and in what piece of equipment it is located. Additionally, the EPMS will provide access to an executive dashboard that will allow decision-makers to monitor key metrics including PUE in real time. The system will also archive power-monitoring data for future reference, enabling data center managers to generate a variety of informative reports on topics such as energy consumption, load capacity, and power quality. That, in turn, will allow data center managers to identify and proactively address areas of energy inefficiency. Figure 3. Eaton s Foreseer Enterprise Monitoring software works in conjunction with building management systems (BMS) to provide comprehensive and real time view of the electrical, mechanical, life safety and security systems. specific servers and applications, enabling data center managers to spot potentially dangerous electrical conditions in real time, see exactly which business services they jeopardize and take prompt preventive action. Enterprise monitoring was implemented in both of our new data centers, said Agar. Our IT and facilities departments will both enjoy access to the same enterprise-wide monitoring technology, enabling our technicians to identify and address power issues as quickly and effectively as they do network and storage problems. Additionally, most enterprise monitoring solutions collect historical data on power usage patterns that can allow facilities managers to levy precise charge backs to business managers based on the actual amount of energy they consume, or perform what if analyses to find the most efficient data center configuration for their environment. The new data centers will be equipped with an electrical power management system (EPMS) and a third-party building management system (BMS). These systems will provide a high level of monitoring and management and, in the case of the BMS system, will also allow the facility operations staff to control the mechanical portions of the facility from a command console, said Agar. They have also been integrated in our new data centers to allow critical data to flow from the BMS platform to the EPMS platform. The BMS system will pass 515 measurements per second to the EPMS, including computer room air handler (CRAH) and chiller status, water temperature, water tank status, generator status, and outside air temperature. The EPMS for our project will incorporate that data into its dashboards and reports, giving it and the facility operations staff a comprehensive view of both power-and SUSTAINABLE PRACTICES Lastly, organizations can further reduce carbon footprint and energy spending by implementing environmentally responsible green IT practices such as consolidating servers through virtualization, creating hot-and-cold aisles, and deploying modern UPSs. Coupling ideas like these with deployment of more efficient power and cooling technologies can enable a midsize data center with 1,500 servers to save millions of dollars while dramatically shrinking its contribution to global warming. In keeping with a company-wide commitment to doing business right that has the complete support of the company s chairman and CEO, Eaton s new data centers employ a variety of technologies and practices aimed at conserving power and shrinking our impact on the environment. In designing Project BlueGrass, the project team focused on a design that would be flexible, modular, and scalable enough to stay in front of rapid business/it change and demand. On day one, the electrical cooling infrastructure will support power densities of 90 watts per square foot with upgrade steps at 120 watts per square foot and 180 watts per square foot, said Agar. The rack-level electrical loads are projected to be 4 kilowatt per rack on day one, and to scale up to 8 kilowatt as the IT technology footprint grows within the facilities. Over the data center lifetime, server, and storage virtualization will dramatically limit total power consumption, and save footprint as well. HOT-AND-COLD AISLES The Project BlueGrass data halls are designed to be maintained at a temperature of 74ºF by conditioning and recirculating the air within the room using a CRAH. Heat from the data hall is exchanged by the warm air passing over the coil, which has cool water inside it, resulting in cold air being distributed back into the room and warm water being transported from the coil via closed chilledwater loop to a chiller, said Agar. There, after another

Eaton Takes Own Advice for New LEED Certified Data Centers exchange, heat is passed to the cooling towers via condenser loop, where it is discharged into the atmosphere. Eaton enclosures and thermal management systems are used to create complete isolation between cool inlet air and hot return air. This hot or cold aisle approach eliminates inefficient mixing of hot and cold air. MODERN UPS Eaton modular 9395 UPSs in Energy Saver System mode provide scalable power protection and 99 percent efficiency in a dual-bus architecture. Further, the UPS system is backed by two 3,300 horsepower generators (2 megawatts) capable of delivering 12,470 volts in the event that the site loses utility power are also included in the design. This is consistent with Eaton s N+1 redundancy requirements for these facilities. On day one, one generator is required to provide the power requirements for the site during an outage, said Agar. The generators are supported by a 30,000-gallon diesel tank in the service yard which is projected to allow the facility to operate for 10 days without supplemental fuel in the case of an extended utility outage. Project BlueGrass vividly demonstrates how companies that take a disciplined approach to designing, building and equipping new data centers can deliver IT services not only reliably and cost-effectively but with sustainability as well. Thanks to the rigor with which the team selected vendors and locations, as well as the leading-edge infrastructure resources, power quality equipment and monitoring systems it chose, Eaton will soon be equipped to support at least 20 more years of IT growth while conserving water, energy, and natural resources in ways that will generate tens of millions of dollars in savings. The good news for other companies is that they can achieve similar results by employing the same best practices. Figure 4. Eaton s Heat Containment System (HCS) technology, featuring the scalable Paramount Enclosure System, protects mission-critical electronics and servers while lowering air handling-related power usage by up to 30 percent. Reprinted from the November/December 2011 issue of Mission Critical magazine www.missioncriticalmagazine.com

Hot exhaust air is removed from the server enclosures via HCS chimneys located on the top rear of the racks and is then directed back to precision cooling units (the CRACs) by way of a ceiling plenum.