IBM DS4000 Service Alert Setup Instructions

Similar documents
Platform LSF Version 9 Release 1.1. Migrating on Windows SC

IBM Rational Synergy DCM-GUI

Platform LSF Version 9 Release 1.3. Migrating on Windows SC

IBM Spectrum LSF Process Manager Version 10 Release 1. Release Notes IBM GI

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide

Using Client Security with Policy Director

iscsi Configuration Manager Version 2.0

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony

IBM Rational Development and Test Environment for System z Version Release Letter GI

IBM Software. Maximo Asset Management Version 7 Releases. Enabling Enterprise Mode for Internet Explorer. Maximo Report Designer/Architect.

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

Build integration overview: Rational Team Concert and IBM UrbanCode Deploy

IBM Kenexa LCMS Premier on Cloud. Release Notes. Version 9.3

IBM Storage Driver for OpenStack Version Release Notes

IBM SmartCloud for Social Business. Sametime Chat and Meetings mobile User's Guide

Best practices. Reducing concurrent SIM connection requests to SSM for Windows IBM Platform Symphony

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide

IBM License Metric Tool Enablement Guide

IBM z/os Management Facility V2R1 Solution Guide IBM Redbooks Solution Guide

IBM Security QRadar Version Forwarding Logs Using Tail2Syslog Technical Note

Limitations and Workarounds Supplement

Utility Capacity on Demand: What Utility CoD Is and How to Use It

IBM Maximo for Aviation MRO Version 7 Release 6. Installation Guide IBM

IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide

IBM Security QRadar Version Customizing the Right-Click Menu Technical Note

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

Getting Started with InfoSphere Streams Quick Start Edition (VMware)

CONFIGURING SSO FOR FILENET P8 DOCUMENTS

A Quick Look at IBM SmartCloud Monitoring. Author: Larry McWilliams, IBM Tivoli Integration of Competency Document Version 1, Update:

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

IBM. IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns. Version 2 Release 1 BA

Integrated use of IBM WebSphere Adapter for Siebel and SAP with WPS Relationship Service. Quick Start Scenarios

IBM Operations Analytics - Log Analysis: Network Manager Insight Pack Version 1 Release 4.1 GI IBM

IBM emessage Version 8.x and higher. Account Startup Overview

Version 9 Release 0. IBM i2 Analyst's Notebook Configuration IBM

Netcool/Impact Version Release Notes GI

IBM. Networking INETD. IBM i. Version 7.2

Migrating Classifications with Migration Manager

IBM 6 Gb Performance Optimized HBA IBM Redbooks Product Guide

IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version Release Notes

IBM Maximo for Service Providers Version 7 Release 6. Installation Guide

Version 2 Release 1. IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns IBM BA

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

Version 9 Release 0. IBM i2 Analyst's Notebook Premium Configuration IBM

Integrated Management Module (IMM) Support on IBM System x and BladeCenter Servers

Setting Up Swagger UI for a Production Environment

IBM FlashSystem V Quick Start Guide IBM GI

IBM VisualAge for Java,Version3.5. External Version Control

IBM Content Analytics with Enterprise Search Version 3.0. Expanding queries and influencing how documents are ranked in the results

IBM Cognos Dynamic Query Analyzer Version Installation and Configuration Guide IBM

Using application properties in IBM Cúram Social Program Management JUnit tests

IBM LoadLeveler Version 5 Release 1. Documentation Update: IBM LoadLeveler Version 5 Release 1 IBM

IBM Geographically Dispersed Resiliency for Power Systems. Version Release Notes IBM

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

Printing Systems Division. Infoprint Manager for AIX NLV Release Notes

IBM. Release Notes November IBM Copy Services Manager. Version 6 Release 1

Patch Management for Solaris

Tivoli Access Manager for Enterprise Single Sign-On

IBM Storage Driver for OpenStack Version Installation Guide SC

Best practices. Linux system tuning for heavilyloaded. IBM Platform Symphony

Tivoli Access Manager for Enterprise Single Sign-On

Engineering and Scientific Subroutine Library for AIX, Version 4 Release 2. Installation GA

IBM. Cúram JMX Report Generator Guide

IBM Endpoint Manager Version 9.1. Patch Management for Ubuntu User's Guide

IBM WebSphere Sample Adapter for Enterprise Information System Simulator Deployment and Testing on WPS 7.0. Quick Start Scenarios

IBM Tivoli Monitoring for Databases. Release Notes. Version SC

Contents. Configuring AD SSO for Platform Symphony API Page 2 of 8

IBM OpenPages GRC Platform - Version Interim Fix 1. Interim Fix ReadMe

Lotus Forms Designer 3. What s New

Release Notes. IBM Security Identity Manager GroupWise Adapter. Version First Edition (September 13, 2013)

Version 1.2 Tivoli Integrated Portal 2.2. Tivoli Integrated Portal Customization guide

IBM High IOPS SSD PCIe Adapters IBM System x at-a-glance guide

IBM Tivoli Directory Server Version 5.2 Client Readme

Tivoli Access Manager for Enterprise Single Sign-On

Application and Database Protection in a VMware vsphere Environment

IBM License Metric Tool Version Readme File for: IBM License Metric Tool, Fix Pack TIV-LMT-FP0001

Installing Watson Content Analytics 3.5 Fix Pack 1 on WebSphere Application Server Network Deployment 8.5.5

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM Maximo Calibration Version 7 Release 5. Installation Guide

Setting Up Swagger UI on WebSphere

Proposal for a Tivoli Storage Manager Client system migration from Solaris with VxFS to Linux with GPFS or AIX with GPFS or JFS2

Networking Bootstrap Protocol

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

IBM Copy Services Manager Version 6 Release 1. Release Notes August 2016 IBM

IBM Decision Server Insights. Installation Guide. Version 8 Release 6

IBM Storage Driver for OpenStack Version Installation Guide SC

Release Notes. IBM Tivoli Identity Manager GroupWise Adapter. Version First Edition (September 13, 2013)

IBM Storage Driver for OpenStack Version Release Notes

Release Notes. IBM Tivoli Identity Manager Oracle PeopleTools Adapter. Version First Edition (May 29, 2009)

IBM OpenPages GRC Platform Version Interim Fix 5. Interim Fix ReadMe

IBM Netcool/OMNIbus 8.1 Web GUI Event List: sending NodeClickedOn data using Netcool/Impact. Licensed Materials Property of IBM

Enterprise Caching in a Mobile Environment IBM Redbooks Solution Guide

IBM Maximo Spatial Asset Management Version 7 Release 5. Installation Guide

IBM Spectrum LSF Version 10 Release 1. Readme IBM

IBM Security QRadar Version 7 Release 3. Community Edition IBM

Tivoli Endpoint Manager for Patch Management - AIX. User s Guide

Transcription:

IBM DS4000 Service Alert Setup Instructions Updated 05/30/06 Version 9.16 (C) Copyright International Business Machines Corporation 1999, 2006. All rights reserved. US Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Note: Before using this information and the product it supports, read the general information under "NOTICES and TRADEMARKS" in this document.

Table of Contents About this file... 3 Who should read this file... 3 How to get help... 3 DS4000 Service Alert description... 3 Service offering contract... 3 Activating DS4000 Service Alert... 4 Prerequisites... 4 Creating a user profile (userdata.txt)... 4 Renaming the storage subsystem... 5 Synchronizing the controller clock... 7 Configuring Storage Manager to Send Alerts... 7 Activate the Service Alerts with IBM Technical Services (ITS)... 10 Upgrading to DS4000 Storage Manager 9.x with Service Alert previously installed... 10 Notices... 11 Trademarks... 12 IBM DS4000 Service Alert Setup Page 2

About this file This file contains the most recent information about the Service Alert for the IBM System Storage DS4000 Storage Server. You should print and review the contents of this file before using the DS4000 Service Alert. You can find additional documentation for the various models of DS4000 at the following Web site: http://www-1.ibm.com/servers/storage/disk/ds4000/index.html Who should read this file This readme file is intended for storage and network administrators. How to get help Go to the following Web sites for the most current DS4000 documentation and support information: http://www-1.ibm.com/servers/storage/disk/ds4000/index.html DS4000 Service Alert description DS4000 Service Alert (hereafter called Service Alert) is a feature of the IBM System Storage DS4000 Storage Manager that monitors system health and automatically notifies the IBM Support Center when problems occur. Service Alert sends an e-mail to a call management center that identifies your system and captures any error information that can identify the problem. The IBM support center analyzes the contents of the e-mail alert and contacts you with the appropriate service action. The IBM DS4000 Service Alert, complements, but does not replace the basic hardware maintenance agreement in place for the DS4000 storage subsystems. With the DS4000 Service Alert activated, the IBM support center will monitor Service Alert e-mails with the same coverage being provided in the basic hardware maintenance agreement Service offering contract 1. Following is an overview of the process for obtaining a service offering contract: 2. The account team submits an RPQ requesting Service Alert, using the designated country process. 3. The System Storage Hub receives the request and ensures that the following prerequisites are met: The machine type, model, and serial number are provided unless this is for a DS4000 on order (not yet shipped). The DS4000 management station is running DS4000 Storage Manager client version 9.12 or higher. The DS4000 firmware level is at 05.3x.xx.xx or higher The DS4000 management station has Internet access and e-mail capability. Willingness to sign the service contract with the applicable fee. The account team can provide details regarding billing and fees. 4 After the prerequisites are confirmed, the service offering contract is sent. 5 When the contract has been signed, the approval is sent from the System Storage Hub, with the support team copied. IBM DS4000 Service Alert Setup Page 3

Activating DS4000 Service Alert This section contains the instructions required to activate Service Alert. You must do all of the following tasks: Verify the prerequisites Create a user profile (userdata.txt) Rename each storage subsystem and synchronize the controller clock Configure Storage Manager to send alerts Activate the Service Alerts with IBM Technical Services (ITS) Prerequisites Before you use Service Alert, you must install DS4000 Storage Manager Client version 9.12 or higher in the DS4000 management station. In addition, the DS4000 firmware levels must be at 05.3x.xx.xx or higher. You can download the DS4000 Storage Manager Client and firmware from the following Web sites: http://www-1.ibm.com/servers/storage/support/disk/ds4800/ http://www-1.ibm.com/servers/storage/support/disk/ds4500/ (FAStT 900) http://www-1.ibm.com/servers/storage/support/disk/ds4400/ (FAStT 700) http://www-1.ibm.com/servers/storage/support/disk/ds4300/ (FAStT 600) http://www-1.ibm.com/servers/storage/support/disk/ds4100/ (FAStT 100) http://www-1.ibm.com/servers/storage/support/disk/fastt500/ http://www-1.ibm.com/servers/storage/support/disk/fastt200/ During the Storage Manager installation, be sure to enable the Event Monitor Service. If Storage Manager 9.12 or higher has already been installed, make sure that the IBM DS4000 Event Monitor service was enabled. If not, you must uninstall the DS4000 Storage Manager client and reinstall it with the Event Monitor service enabled. NOTE: DS4000 Event Monitor service is not supported on Novell Netware 6. You must use a management station with other operating systems installed, such as Windows Server 2003, Windows 2000 or Windows NT4. Creating a user profile (userdata.txt) The user profile is a text file that contains your individual contact information. It is placed at the top of the e-mail that Service Alert generates. A template is provided, which you can download and edit using any text editor. IMPORTANT: The user profile file name must be userdata.txt. The file content must be in the format as described in step 2. In addition, the file must be placed in the appropriate directory in the DS4000 management station as indicated in step 4. Perform the following steps to create the user profile: 1 Download the userdata.txt template file from one of the following Web sites: http://www-1.ibm.com/servers/storage/support/disk/ds4800/downloading.html http://www-1.ibm.com/servers/storage/support/disk/ds4500/downloading.html (FAStT 900) http://www-1.ibm.com/servers/storage/support/disk/ds4400/downloading.html (FAStT 700) http://www-1.ibm.com/servers/storage/support/disk/ds4300/downloading.html (FAStT 600) http://www-1.ibm.com/servers/storage/support/disk/ds4100/downloading.html (FAStT 100) http://www-1.ibm.com/servers/storage/support/disk/fastt500/downloading.html http://www-1.ibm.com/servers/storage/support/disk/fastt200/downloading.html The userdata.txt template is named "userdata.txt". IBM DS4000 Service Alert Setup Page 4

2 Type in the required information. There should be seven lines of information in the file. The first line should always be "Title: IBM DS4000 Product". The other lines contain the company name, company address, contact name, contact phone number, alternate phone number, and machine location information. Do not split the information for a given item; for example, do not put the company address on multiple lines. Use only one line for each item. Note: When you type in the text for the userdata.txt file, the colon (:) is the only legal separator between the required label and the data. No extraneous data is allowed (blanks, commas, and so on) in the label unless specified. Labels are not case sensitive. The Title field of the userdata.txt file must always be "IBM DS4000 Product". The rest of the fields should be completed for your specific DS4000 installation. This is an example of a completed userdata.txt user profile: Title: IBM DS4000 Product Company name: IBM (73HA Department) Address: 3039 Cornwallis Road, RTP, NC 27709 Contact name: John Doe Contact phone number: 919-254-0000 Alternate phone number: 919-254-0001 Machine location: Building 205, Lab 42 3 Save the userdata.txt file as a plain text file. 4 Store the userdata.txt file in the appropriate subdirectory of the DS4000 Storage Server management station, depending on the operating system that is installed in the management station: For Microsoft(R) Windows(R) Server 2003, Windows 2000 and Windows NT4, store the userdata.txt file in the "\IBM_DS4000\client\data" directory on the drive where Storage Manager was installed. Typically: C:\IBM_DS4000\client\data For AIX(R), Solaris, HP-UX and Linux operating systems, store the userdata.txt file in the /var/opt/sm directory. For Novell NetWare, store the userdata.txt file in the sys:/ibm_ds4000/client/data directory. VMware ESX servers that are connected to a DS4000 will require a separate workstation for DS4000 management. Service Alert is only supported in a VMware ESX and DS4000 environment by way of the remote management station. Renaming the storage subsystem NOTE: If you are an existing user of Service Alert which had been installed with Storage Manager version 8.x, please read Upgrading to DS4000 Storage Manager 9.x with Service Alert previously installed one page 10 before continuing. When you register for Service Alert, you must change the existing node ID of each DS4000. Service Alert uses this new name to identify which DS4000 has generated the problem e-mail. You rename the storage subsystem using DS4000 Storage Manager client. Before you can rename the storage subsystem, you must know the DS4000 machine type, model, and serial number. Depending on the model of DS4000, the information is located in the following areas: IBM DS4000 Service Alert Setup Page 5

For the FAStT200: the label with this information is located on the right side on the rear lip of the controller enclosure. NOTE: Be careful not to use the information of the drive expansion enclosure. The FAStT200 looks very similar to the FAStT EXP500 drive expansion enclosure. For the FAStT500, DS4300, DS4400, and DS4500 the label with this information is located on the right side on the rear lip of the controller enclosure. NOTE: Be careful not to use the information of the drive expansion enclosure. The DS4300 looks very similar to the DS4000 EXP700 drive expansion enclosure. For the DS4800: the label with this information is located on the left side of the rack mounting flange in the rear of the controller enclosure. Perform the following steps to rename the storage subsystem: 1 Open the DS4000 Storage Manager client Enterprise Management window. 2 Double click on the storage system that you want to rename. The Subsystem Management Window opens. 3 Click Storage Subsystem --> Rename. The Rename Storage Subsystem window opens. 4 Type the new name for the subsystem. You must use the following naming convention for the new name; any errors in the format of the new name can result in delays or denial of IBM service support. The new name cannot contain more than 30 characters. Please use the following naming convention: ttttmmm-sssssss-cust_nodeid_reference Where: tttt is the 4-digit IBM machine type of the product mmm is the 3-digit IBM model number for the product - is the required separator sssssss is the 7-digit IBM serial number for the machine - is the required separator subsystem_name is any name for the subsystem IMPORTANT: No extra characters are allowed before the start of the "cust_nodeid_reference" string. Following are some examples of a new storage subsystem name: 174290U-23A1234-IBM_Eng 17421RU-23A1235-IBM_Acctg 35521RX-23A1236-IBM_Mktg 35422RU-23A1237-IBM_Mfg IBM DS4000 Service Alert Setup Page 6

NOTE: If you have previously installed Service Alert with DS4000 Storage Manager version 8.x, a different naming convention was used. It is not necessary to change any host names when upgrading to DS4000 Storage Manager version 9.12, but if you do rename a host, you must use the new naming convention described in this step. 5 Click OK to save the new name. Steps 1-5 must be performed for each DS4000 that supports Service Alert. Synchronizing the controller clock This step is optional. If performed, it facilitates the trouble-shooting session because the time that the alert e-mail is sent is about the same as the time that the errors occurred in the DS4000. To synchronize the controller clock with the time in the DS4000 management station that monitors the alerts, go to the Storage Management window. Select Storage System --> Set Controller Clock. Click OK when the confirmation window opens. Configuring Storage Manager to Send Alerts Important note: Starting with Storage Manager 9.14, ( and depending on the level of firmware installed on the DS4000 controllers), you may have additional options for sending email alerts. These options are to: send event information only; Send event plus profile send event plus support data For Service Alert, specify "event plus profile". You may also be given an option to specify how frequently to send events. For Service Alert, specify every event Perform the following steps: 1 From the DS4000 Storage Manager client s Enterprise Management window, select Exit --> Configure Alerts... The Configure Alerts window opens.. IBM DS4000 Service Alert Setup Page 7

2 Click the Mail Server tab. Enter the following information: Mail (SMTP) server - This is the address of your SMTP server. This server must be able to route data to the Internet domain. Email sender address: This is the sender's e-mail address. This address is displayed on every mail message that is sent to the configured e-mail alert destination. If you have properly created the userdata.txt file, the contents will be displayed under Sender contact information. If this area is blank, refer to Creating a user profile (userdata.txt) on page 4. 3 Click the Email Tab. IBM DS4000 Service Alert Setup Page 8

4 Enter the email address that alerts will be sent to. Email address: This is the email address of the IBM location to which alerts will be sent. Enter one of the following depending on your geographic location: For EMEA and A/P locations: callhome0@de.ibm.com For the following locations use: callhome1@de.ibm.com 5 Click Add. < North America < South and Central America < Caribbean Islands 6 Click OK to close the Configure Alerts window. Note that alerts can also be configured using the Task Assistant. The major difference is that you will be able to configure alerts for individual subsystems or all subsystems. Usually you will want alerts configured for all subsystems. IBM DS4000 Service Alert Setup Page 9

Activate the Service Alerts with IBM Technical Services (ITS) After all previous tasks have been completed; you are ready to activate your system for Service Alert. Call your IBM Support Center. Call the phone number you normally use to report a problem with a DS4000 subsystem. Provide the IBM Machine Type and Model of one of the storage subsystems that Service Alert will be used with. Tell the representative that you are ready to activate the DS4000 Service Alert process. The IBM representative will work with you to test your system setup and ensure that DS4000 Service Alert is working properly. Depending on your configuration, you will be asked to use one of the following procedures to test that Service Alert is working: If you have a DS4000 or expansion enclosure with redundant power supplies perform this test: < Ensure that both power supplies are on. < Close the DS4000 Storage Manager client. < Then turn off one of the redundant power supplies in the DS4000 or DS4000 expansion enclosure. This simulates a power supply failure and a Service Alert will be sent to the IBM e-mail address that you specified in Configuring Storage Manager to Send Alerts on page 9. IMPORTANT: Do not turn off the power supply if this is the only one that is powered on in your storage server or expansion enclosure. See if you can use the alternate test described below. If you have a drive that is unused or not configured you can perform the following test: The IBM Support will assist you in manually failing a non-configured drive in the DS4000 Storage Server using the DS4000 Storage Manager client. Upgrading to DS4000 Storage Manager 9.x with Service Alert previously installed If you had previously installed Service Alert with DS4000 Storage Manager version 8.x, you may notice that a different naming convention for hosts was used than is described in this readme. It is not necessary to change any host names when upgrading to DS4000 Storage Manager version 9.x. However if you do need to rename a host, you must use the new naming convention described in Renaming the Storage Subsystem on page 5. You will need to repeat the tasks described in Configuring Storage Manager to Send Alerts on page 7, and Activate the Service Alerts with IBM Technical Services on page 10 in order to re-define the email server and email addresses used for Service Alert. IBM DS4000 Service Alert Setup Page 10

Notices This information was developed for products and services offered in the U.S.A. and other countries or regions. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-ibm product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. IBM DS4000 Service Alert Setup Page 11

Trademarks The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: AIX IBM FAStT System Storage Microsoft, Windows, and Windows NT are of Microsoft Corporation in the United States, other countries, or both. Novell NetWare is a trademark of Novell Corporation in the United States, other countries, or both. Linux is a trademark of Linus Torvalds in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, and service names may be trademarks or service marks of others. --------------------------------------------------------------------------- (C) Copyright IBM Corporation 2004, 2006 All rights reserved. IBM DS4000 Service Alert Setup Page 12