Building Profile & Facts 1 Location Map & Aerials 4 Floor Plans 5
BUILDING PROFILE & FACTS SHEET 1 Property Name Address Tax Map & Parcel Number Land Area Building Size Experis Data Centers, LLC 8209 Valley Pike, Middletown, Frederick County, VA 22645-1941 90-A-58-C 6.15 Acres (267,955 SF) Includes 15,000 SF Enclosed Card-Access Equipment Yard 75,123 Rentable SF Main Entrance & Surface Parking Lot (Microwave Towers in Use by Existing Tenant) Raised Floor/ Conditioned Space/ Column Space Computer Room #1 Computer Room #2 Computer Room #2a Computer Room #3 Computer Room #4 Total 18,594 SF 12,730 SF 2,771 SF 2,436 SF 4,114 SF 40,645 SF Year Built 1970 / 1984 Renovated 2008-2009 ($10+ Million) Computer Room #1 Containing Ten (10) Liebert 225 kva PDU s UPS/Electrical Equipment for Computer Room #1 Property Owner / Manager Parking Number of Floors Zoning Flood Zone / Map Floor Load Capacity Ceiling Heights Utility Power UPS Power Experis Data Centers, LLC as Agent for Virginia DR Solutions, LLC 48 Surface Spaces (1.97 per 1,000 RSF) One (1), plus mezzanine M-1, Light Industrial Zone C (Outside the 500 Year Flood Plain) Map Panel 5100630175B (July 17, 1978) 1,250 lbs/psf 9 to 20 Raised Floor to Ceiling 24 Raised Floor Electrical Power is Supplied by Rappahannock Electric Cooperative by Two Underground Diverse 13.2kV Feeds Leading to Three Transformers Located in the Secured Equipment Yard. Primary Electrical Service Enters the Building to Independent Electrical Switchgear that Steps Down the Primary Power to 480 Volt and 208 Volt Services. Total Building Utility Load is 3.75 MW. Six (6) 500 kva Liebert Systems (Expansion), Dedicated to Computer Room #1 (~100 watts/sf) Two (2) 500 kva and Two (2) 375 kva Liebert Systems, Dedicated to Computer Rooms #2, #3 & #4 (~50 watts/sf) (Expandable)
BUILDING PROFILE & FACTS SHEET 2 Emergency Generators Two (2) 1.5 MW Kohler Generators w/3,000 Gallon Belly Tanks, Dedicated to Computer Room #1 (Expansion). 48-hour Runtime Capacity at Full Load. Two (2) 1.25 MW Caterpillar Generators and One (1) 750 KW Caterpillar Generator with Two (2) 2,000-Gallon Above-Ground Fuel Storage Tanks and One (1) 275-Gallon Day Tank, Dedicated to Computer Rooms #2, #3, #4 and Common Areas. 72 Hour Runtime Capacity at Full Load. HVAC System The HVAC System is Comprised of Three (3) Carrier 400-Ton Centrifugal Chiller Units and Three (3) 400-Ton BAC Cooling Towers, each recently overhauled. Computer Room #4 Computer Room #1 is Conditioned Using Seven (7) 100-Ton Trane Air Handlers Servicing Through a 24 under floor plenum. Computer Room #2 is Conditioned Using Nineteen (19) Liebert 20-Tons CRAC Units. Computer Room #3 is Conditioned Using Two (2) Liebert 20-Ton CRAC Units and Two (2) Liebert 20-Ton Split Systems. Computer Room #4 is Conditioned Using Two (2) Liebert 20-Ton CRAC Units and Two (2) Liebert 15-Ton CRAC Units. Visitor Entrance Shared Conference Room Water Supply Fire Protection Loading Docks Security Fiber Connectivity Winchester Public Utilities. Emergency Water Provided by Secured On-Site Well with 400 Depth and 80 Gallon per Minute Positive Displacement Lift Pump. Four (4) Pre-Action Sprinkler Systems with ADT/ Honeywell Detection and Alarm System. Two (2) Loading Docks Located in Secure Fenced Yard. Property Has On-Site Security 24 x 7x 365. Entire Perimeter of Property is Secured by Motion-Detecting Fence System. Key Card Access Controls Entrance Gates, All Entry Doors, Equipment Rooms and Individual Computer Rooms. Perimeter (5) and Interior (9) Cameras are Monitored in Central Security Office. Tape Backup Maintained for 90 Days. Verizon Business and Shentel. Access w/ Shentel to AT&T, Embarq, Elantic, NTelos, Sprint, Valley Net, DDR Net, and EchoStar, as well as providing local loop dark and lit services to Equinix in Ashburn.
BUILDING PROFILE & FACTS SHEET 3 Network Operations Center A 972 SF Manned NOC Serves as the Security Access Point for Visitors and Monitoring Equipment for All Critical Operating Systems. Work Recovery/ Conference Rooms The Property Contains Four (4) Disaster/Work Recovery Rooms Containing Ninety Five (95) Work Stations Equipped with Computer and Phone. There are Two (2) Conference Rooms for Use by Clients. Amenities Cafeteria and Vending Area Network Operations Center Interior Finishes The Typical Interior Finish in Areas Other than Computer Rooms Consists of Commercial Grade Carpet, Painted Sheetrock Walls; 2 x2 Inlaid Acoustical Tile Ceiling and Flush Mounted Florescent Lighting, Vinyl Baseboards and Solid- Core Fire-Rated Entry Doors. Foundation Foundation Consists of Continuous Monolithic Slab Poured on Reinforced Concrete. Structural System Steel Frame with Steel Beams and Steel Deck. Roof Pitched Metal-Seamed Roof. Exterior Walls The Interiors and Exteriors of Computer Rooms #3 and #4 are Coated with CITADEL Blast Protection Polymer, Sanctioned by the Department of Defense. Work Recovery Room Elevators One (1) HydraPower Freight, rated at 6,000 lbs at Loading Dock and One (1) Dover Passenger, rated at 4,500 lbs, both Serving the Mezzanine Level. Power Cost Average Total Cost of Electricity, Including Utility Company Fees and Taxes is $.076 per kwh. Cafeteria Seating Area Proximities The Experis Data Center is Strategically Located to the Northern Virginia and Washington DC Markets, and is Accessible by Two International Airports, Washington Dulles and Baltimore. From Experis Data Center to: Washington DC 80 Miles Manassas, VA 45 Miles Reston, VA 70 Miles Dulles Airport 65 Miles Baltimore Airport 115 Miles
LOCATION MAP & AERIALS 4 Location of Experis Data Center 22645-1941 Latitude: 39.017666 Longitude: -78.290927 High A ltitude A erial of Experis Data Center 22645-1941 Latitude: 39.017666 Longitude: -78.290927
FLOOR PLAN 1 ST FLOOR 5
FLOOR PLAN MEZZANINE 6