PMC 530 Series Advanced Multifunction Meter

Similar documents
PMC-630 Series Advanced Multifunction Meter

Designed For Reliability Manufactured To Last

PMC-680i Advanced Utility Power Quality Analyzer

PMC-670 Advanced C&I Power Quality Analyzer

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

Advanced Power Quality Analyzer. For Utility, Industrial and Commercial Power Quality Monitoring.

Revenue Grade General Specifications

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

Ceiec Electric Technology

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

MIC-2 Multi-instrument DATA SHEET

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

!"!#$!%&'()!%*+,-%./0/123&&45&

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Energy Management Energy Transducer Type ET112

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Bus Bar Protection Relay B-PRO 4000

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Acuvim L Series. Multifunction Power Meters FEATURES

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MINER-S Station Controller. Substation Automation

Revenue Grade with DATA-LOGGING and WAVEFORM CAPTURE

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

Multifunction Transducer MT440

General information. Display. Supply voltage. Input current

Power Meter PowerMonitor 500

Digital Multifunction Meters. Digital Multifunction Meters

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Metering Devices IQ 300

MINER-S Station Controller

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Voltage Transducer UMT516 / MT516

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

Energy Management Solutions

EM6400 series Multi-Function meters

General information. Display. Supply voltage. Input current

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

extending the boundaries of technology evolution of proven technology FEATURES

General information. Display. Supply voltage. Input current

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

FU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Protection Relays PHASE & RESIDUAL OVERCURRENT

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

LBVR1718. Description. Features channel paperless recorder

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

General information. Display. Supply voltage. Input current

Relion 611 series. 611 series Type Test Certificate

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

UW Purchase Specification Section

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

HMI software. gems 3100 Multi-Channel Power Meter

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Features. Applications and Benefits TRC ELECTRONICS, INC

Type VRLTC tap changer

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

Scout-S Station Controller

Gelo LED Driver 100W, Single output RGLD100-24

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

POWER METER HC Features

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

USER MANUAL 2012 V1.1

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

QUALITROL QTMS Transformer Monitoring System

General information. Display. Supply voltage

VCL-TP, Teleprotection Equipment

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

General information. Display. Supply voltage

02/11/2015

PM800 series. Applications

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Electronic Submeter with Advanced WiFi Ethernet Capability

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Transformer Protection Relay

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

General information. Display. Supply voltage. Input current

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

Transcription:

IEC 62053 22 Class 0.5S WF Capture @ 128 samples/cycle WF and Data Recording Harmonics & Transient Monitoring I residual Monitoring Setpoint Alarms, SOE Log RS 485 and I/O Capabilities Large, Bright, Backlit LCD Display with Wide Viewing Angle Standard Tropicalization Industrial Grade Components Metal Enclosure with No Openings Extended Temperature Extended Warranty

SOE Log 64 events time stamped to ±1ms resolution Setup changes, Setpoint events and I/O operations Data Recorder Log 2 Data Recorder Logs of 6 parameters each Recording interval from 1s to 40 days Configurable depth and recording offset Combined capacity of 600 measurements The PMC 530 series Advanced Digital Multifunction Meter is CET s latest offer for the low, medium and high voltage power/energy metering market. Housed in an industry standard DIN form factor measuring 96mmx96mmx125mm, the PMC 530 is perfectly suited for utility, industrial or commercial applications. The meter features quality construction with metal enclosure, multifunction and high accuracy measurements, transient detection and waveform recording capabilities, extensive I/O and communications configurations, and an easy to read, back lit LCD display, capable of displaying 3 phase measurements at once. The meter comes standard with four Digital Inputs for status monitoring and two Digital Outputs for control or alarming applications. Further, the PMC 530 optionally provides an I residual input, an Analog Input, an Analog Output and additional Digital Outputs. The standard SOE Log records all setup changes, DI and Setpoint status changes, and DO operations in 1ms resolution. With the standard RS485 port and Modbus protocol support, the PMC 530 becomes a vital component of an intelligent, multifunction monitoring solution for any Power and Energy Management systems. Typical Applications Analog meter replacement Low, medium and high voltage applications Industrial and commercial panel metering Substation, building and factory automation I residual monitoring Power quality monitoring and waveform recording Features summary Easy of use Large, backlit, easy to read 5 line LCD display with wide viewing angle Password protected setup via front panel or our free PMC Setup software Easy installation with mounting slide bars, no tools required Basic Measurements 3 phase voltage, current and power measurements Bi directional energy measurements TOU tariff metering supporting 4 tariff rates, 6 seasons and 1 daily profile with 10 periods Demands kw Total Demands and Peak Demands for This Month and Last Month Power Quality Voltage and Current Unbalance THD, TOHD, TEHD and K Factor Individual harmonics up to 31 st on board WF Capture at 128 samples/cycle for harmonics analysis up to 63 rd WF Recording of all Voltage and Current inputs at 16 samples/cycle for 12 cycles with 3 pre fault cycles and a capacity of 3 records I residual ALARM and TRIP protection functions Setpoints 9 user programmable setpoints Configurable threshold and time delay DO and WF Recording trigger High speed Transient Voltage and Current Setpoints I residual Input (Residual Current) Requires an optional, external zero sequence CT Two levels of alarm ALARM and TRIP. Each alarm level: Can be enabled individually Has its own programmable threshold and time delay Logs an SOE event AND triggers a dedicated DO when activated Analog Input 0 20 / 4 20mA DC input Can be used to measure external transducer signal Programmable zero and full scales Analog Output 0 20 / 4 20mA DC output Can be keyed to any measured quantity Programmable zero and full scales Digital Inputs 4 channels for external status monitoring Volts free dry contact, 24 VDC internally wetted 1000 Hz sampling Digital Outputs Up to a maximum of 4 channels Form A mechanical relays 2 or 4 channels DO1 is reserved for I residual ALARM if present AND enabled DO2 is reserved for I residual TRIP if present AND enabled DO3 and DO4 are available for general purpose control Form A SS Relays 2 optional channels for energy pulsing applications DO3 is reserved for kwh pulsing DO4 is reserved for kvarh pulsing Front Panel LED Pulse Outputs kwh and kvarh energy pulse outputs for accuracy testing Communications Port 1 Optically isolated RS485 port Baud rate from 1200 to 19,200bps Modbus RTU protocol Port 2 Optically isolated RS485 port Baud rate from 4800 to 19,200bps Modbus RTU protocol Profibus Auto baud from 9600bps to 12Mbps Profibus DP protocol Ethernet 10/100BaseT Ethernet with RJ45 connection Modbus RTU over TCP/IP and Modbus TCP protocols Real time clock Battery backed real time clock @6ppm (0.5s per day)* System integration Supported by our PMC Setup software and PecStar Integrated Automation System Easy integration into other Automation or SCADA systems via Modbus RTU and Profibus DP protocols *Supported by Firmware Version V3.1x.06 or later

Technical Specifications Standard (Un) Optional (Un) PT Ratio Frequency Standard (In / Imax) Optional (In / Imax) CT Ratio Standard Sampling Hysteresis Voltage Inputs (V1, V2, V3, VN) 220VLN/380VLL 57.74VLN/100VLL 10% to 120% Un 1 2200 1.2xUn continuous, 2xUn for 10s <0.5VA per phase 45 65Hz Current Inputs (I11, I12, I21, I22, I31, I32) 5A / 6A 1A / 1.2A 0.1% to 120% In 1 6,000 (5A) or 1 30,000 (1A) 1.2xIn continuous, 20xIn for 1s <0.3VA per phase Power Supply (L+, N, GND) 95 250VAC/VDC ± 10%, 47 440HZ <4W Digital Inputs (DI1, DI2, DI3, DI4, DIC) Dry contact, 24VDC internally wetted 1000Hz 20ms minimum Digital Outputs (DO11, DO12, DO21, DO22, DO3, M34, DO4) Form A Mechanical Relay Loading 5A @ 250VAC or 30VDC Pulse Outputs (kwh, kvarh) Isolation Max. Load Voltage Max. Forward Current Nominal Input Parameter Loading Nominal Current Nominal Output Accuracy Frequency Line Length Dielectric Strength I residual Sensor Models Operating Temp. Storage Temp. Humidity Atmospheric Pressure Pollution Degree Measurement Category Panel Cutout Unit Dimensions IP Rating Shipping Weight Shipping Dimensions Form A Solid State Relay Optical 80V 50mA I residual Input (I41, I42) 1V 1% to 120% Nominal Analog Input (I41, I42) 0 20 / 4 20 ma 24 ma maximum Analog Output (AO+, AO ) 0 20 / 4 20 ma Selectable 500 Ω maximum 24 ma maximum I residual Sensor (Zero Sequence CT) 1A 1V 1.2A 1% 50 / 60Hz 4000mm 2.5kV @ 1 minute PMC MIR 35, PMC MIR 50, PMC MIR 75, PMC MIR 120 Environmental Conditions 25 C to 70 C 40 C to 85 C 5% to 95% non condensing 70 kpa to 106 kpa 2 CAT III Mechanical Characteristics 92x92 mm (3.62 x3.62 ) 96x96x125 mm (3.78 x3.78 4.92 ) 52 1.1 kg 170x145x155 mm (6.69 x5.71 6.10 ) Accuracy Parameter Accuracy Resolution Voltage ±0.2% reading 0.01V Current ±0.2% reading + 0.05% F.S. 0.001A kw, kvar, kva IEC 62053 22 Class 0.5S 0.001k kwh, kvah IEC 62053 22 Class 0.5S 0.001kXh kvarh IEC 62053 23 Class 2 0.001kvarh Power factor IEC 62053 22 Class 0.5S 0.001 Frequency ±0.02Hz 0.01Hz Harmonics IEC 61000 4 7 Class B 0.1% K Factor IEC 61000 4 7 Class B 0.1 V,I Phase angles ±1 0.01 AI, I residual ±1.0% F.S. 0.01mA AO ±1.0% F.S. Models and Measurements Measurements PMC 530A PMC 530B PMC 530C VLN per phase and Avg VLL per phase and Avg Voltage phase angles Current per phase and Avg Current phase angles kw per phase and Total kvar per phase and Total kva per phase and Total PF per phase and Total kwh Imp, Exp, Total, Net kvarh Imp, Exp, Total, Net kvah Total Frequency RS485 Port kwh & kvarh LED Pulse Demands and TOU Power Quality Harmonics (2 nd to 31 st ) V and I Unbalance WF Recording Log (3) WF Capture I residual ALARM and TRIP I residual * * * Setpoint and Logging Setpoint (9) SOE Log (64) Data Recorder Log (2) Inputs and Outputs DI 4 4 4 DO (Mechanical) 2 / 4* 2 / 4* 2 / 4* DO (Solid State) 2* 2* 2* AI (0 20 / 4 20mA) 1* 1* 1* AO (0 20 / 4 20mA) 1* 1* 1* Communications Modbus RTU RS485 2* 2* 2* Profibus DP 1 # N.A. N.A. Ethernet 1* 1* 1* Standard *Optional # Profibus option excludes all other Comm. options

Device View and Dimensions Front View Side View Panel Cutout Accessories 4DI+4DO+2xRS485 4DI+2DO+1AO+1AI+1xProfibus DP 4DI+2DO+1AO+1AI+1XRS 485+1xEthernet I residual Sensor (Zero Sequence CT) PMC MIR 35, 35mm Inner Diameter PMC MIR 50, 50mm Inner Diameter PMC MIR 75, 75mm Inner Diameter PMC MIR 120, 120mm Inner Diameter

Standards of Compliance Safety Requirements CE LVD 2006/95/EC EN 61010 1 2001 Insulation IEC 60255 5 2000 Dielectric Test 2kV @ 1 minute Insulation Resistance >100MΩ Impulse Voltage 5kV, 1.2/50µs Electromagnetic Compatibility CE EMC Directive 2004/108/EC (EN61326: 2006) Immunity Tests Electrostatic Discharge IEC 61000 4 2:2008 Radiated Fields IEC 61000 4 3:2008 Fast Transients IEC 61000 4 4:2004 Surges IEC 61000 4 5:2005 Conducted Disturbances IEC 61000 4 6:2008 Magnetic Fields IEC 61000 4 8:2009 Voltage Dips and Interruptions IEC 61000 4 11:2004 Oscillatory Waves IEC 61000 4 12:1996 Emission Tests Limits and methods of measurement of electromagnetic disturbance characteristics of industrial, scientific EN 55011 2009 (CISPR 11) and medical (ISM) radio frequency equipment Limits and methods of measurement of radio disturbance characteristics of information technology equipment Limits for harmonic current emissions for equipment with rated current 16 A Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current 16 A Emission standard for residential, commercial and light industrial environments Electromagnetic Emission Tests for Measuring Relays and Protection Equipment Radio Frequency Devices Unintentional Radiators Limits and methods of measurement EN 55022 2006+A1 2007 (CISPR 22) EN 61000 3 2 2006+A1 2009 EN 61000 3 3 2006 EN 61000 6 3 2007 IEC 60255 25:2000 47 CFR FCC Part 15 Subpart B ANSI C63.4: 2009 Mechanical Tests Vibration Test Response IEC 60255 21 1 Endurance IEC 60255 21 1 Shock Test Response IEC 60255 21 2 Endurance IEC 60255 21 2 Bump Test IEC 60255 21 2 Ordering Information Accessories Ordering Information I residual Sensor Model # Inner Diameter (mm) Phase Current PMC MIR 35 35 0A to 63A PMC MIR 50 50 63A to 125A PMC MIR 75 75 125A to 250A PMC MIR 120 120 250A to 1000A Ceiec Electric Technology Inc. A: 8/F, WestSide, Building 201, Terra Industrial & Tradepark Che Gong Miao, Shenzhen, Guangdong, P. R. China 518040 T: +86.755.8341.5187, +86.755.8342.3089x627 F: +86.755.8341.0291 E: sales.international@ceiec electric.com W: www.ceiec electric.com Your Local Representative CET, PMC and PecStar are trademarks or registered trademarks of Ceiec Electric Technology Inc. Other marks used herein are the property of their respective owners. CET reserves the right to update the specifications without notification. Revision Date: March 4, 2011