Digital Dimmer Unit Instruction Manual

Similar documents
Digital Dimmer Unit with RCK system Instruction Manual

Digital Dimmer Unit Instruction Manual

DMX Switch Pack Instruction Manual

Series400 Dimming Bar Instruction Manual

Portable Wireless Dimmer Instruction Manual

Hoist Controller for Low Voltage Hoist Instruction Manual

Hoist / Motor Controller Instruction Manual

Hoist Controller for Low Voltage Hoist

Hoist Controller for Low Voltage Hoist Instruction Manual

DST 4-way DMX/AC Power Splitter Instruction Manual

DST8-DIN 8-way DMX Splitter Instruction Manual

Wireless DMX Transmitter/Receiver/Splitt Instruction Manual

Hoist Controller for Direct Voltage Hoist Instruction Manual

House Light Controller

Digital Remote for Hoist Controller Instruction Manual

Wireless Motor Controller Instruction Manual

Network Dimmer Pack Instruction Manual

2300W output in each channel DMX 512 control DMX addressing per channel (Patch) Preheat Channel test heat controlled super silence ventilator

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Installation and User Guide

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

MOTION-8D 8-channel hoist controller with analogue remote control User s manual

SPICE RACK DIMMER OPERATING MANUAL

English USER'S MANUAL DMX MENU UP DOWN ESC. Please read before use

Manual. Dimmer DMD-12-2

LED Master 64. Manual. Please read these instructions carefully before use. Order code: BOTE04

IGLOO IGLOO EASY INSTRUCTION MANUAL

TB-1230 QW. User Manual Please read the instruc on carefully before use

IGLOO IGLOO EASY INSTRUCTION MANUAL

ANYtronics smartdim. 12 Channel Dimming System

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

MATRIX LED LED User Manual Please read the instructions carefully before use

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

PX175. DMX-DALI Converter MANUAL

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

LED W RGBA User Manual

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

User Manual Please read the instructions carefully before use

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

Dimmer DPX terminal

LIGHT AND EASY LED User Guide Please read these instructions carefully before use

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

VBAR 270. User Manual. Version 1.2

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

Installation and User Guide

UV Power Flood. User Manual. Order code: EQLED029

Compulite Systems (2000) Ltd.

CP 64 BD15 CP 64 PD15

CDP 405 Digital Dimmer Pack

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

Endura 1Q120 RGBW COB Exterior Fixture

UV Spectra Batten 12 x 5W UV LEDs

Vector Beam White. User Manual. Order code: LEDJ265

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

COB100/200W 2in1/3in1 led Par Light

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

DS-1312 USER'S MANUAL

Crossfire. User Manual. Order code: EQLED061

DX-610/DX CH DMX Dimmer Pack User Manual

SATELLITE QUICK OPERATION

Gobo Projector XP 80W

PF LED Profile. User Manual

English MDP CH. DIGITAL MODULE DIMMER. Instruction Manual

Blitzer Strobe. User Manual. Order code: EQLED366

Manual. DP-6 S Dimmer Pack

MATRIX 25E. Matrix Beam Wash, ArtNet, RDM. User manual. Please read the instructions carefully before use

ZF LED Zoom Fresnel. User Manual

Metro-Optical Transport Access Nodes

NIR Moisture Analyzer KB-30

Four-channel DC Controller DMX Instruction &Maintenance Manual

Vortex. User Manual. Order code: EQLED073

MODEL 805 USER MANUAL

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

DPX-620III 6-Ch. dimmer pack. user manual

D-Pack 6 Classic ORDERCODE 50315

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

RGB Power Batten. User Manual. Order code: EQLED032

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

High Power Electronic Gear Installation and operation Guide

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

Party Dimmer IEC ORDERCODE 50324

CMSA-100 Manual. Cinema Media Server Automation

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

1 Channel Sliding Profile Dimmer ORDERCODE 50425

P3-RS Remote Slave Module

PX165. DMX Splitter INSTRUCTION MANUAL

DarkFX Spot 670 User Manual English

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

LED Commander 16/2 DMX controller. user manual

User Manual Charter Street Los Angeles CA

Architectural Lighting Controller AC612 XU User Manual

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

i.shine 1136 RGBW Color Stainer CN USER MANUAL

Transcription:

Digital Dimmer Unit Instruction Manual Models: DDPx1210, DDPx1213, DDPx1216 DDPx6025, DDPx6032, DDPx3025 version 4.0 since 6 July 2018 ATTENTION! This instruction manual contains important information about the installation and the use of the equipment. Please read and follow these instructions carefully. Always ensure that the power to the equipment is disconnected before opening the equipment or commencing any maintenance work. DDP12XX_en_manual_M018.doc ( 1 / 20)

General information IMPORTANT INSTRUCTIONS! All safety and operating instructions should be read before the equipment is installed or operated. IMPORTANT SAFETY INFORMATION The following general safety precautions have to be observed during all phases of operation, service, and the repair of this equipment. Failure to comply with these precautions or with specific warnings in this manual violates safety standards of design, manufacture, and the intended use of this equipment. Do not operate in an explosive atmosphere! Do not operate this equipment in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard. Water, moisture, heat and humidity Do not operate this equipment near water or in areas with wet floors, or in high humidity atmosphere, where condensation forms on the equipment. It should never be placed near or over a heat register or other source of heated air. It should not be installed or operated without proper ventilation. Power connections This equipment must be earthed. Let the equipment adapt the environment for at least 10 minutes after unpacking. Please double check the signals of the power cable. Cable must be 5-wire (3L+N+E) with the CEE form input socket 32A/63A 5-pin or hardwired to the installation rack. Output connection The output terminals are located inside the dimmer. Live, neutral and earth connections must be made to all load equipment. Have a look at the PCB for more information about connection of outputs and the power input. DMX Input connection DMX512 standard 3-pin and 5-pin XLR connectors are located on the rear panel of DDP12xx. DMX input is optically isolated. Analogue input (standard 0-10V) is made via the HD-SUB 15-pin connector. ( 2 / 20)

Functions and Control Front panel: Rear panel: 1. GFI63 or 80A, 30mA / *main switch B models 2. Indicator of main input 3. Circuit breakers 1P for DDP model and 1P+N for DDPN model 4. Output load indication /off when the lamp connection and channel level are set to zero/ 5. ESC button 6. ENCODER 7. ENTER button ( 3 / 20)

DMX input/output Analog/Scene input SUB HD15 Power cable 5G6mm2 or 5G10mm2 GND grounding point Navigation menu The initial menu indicates the DMX start address, DMX status, inside dimmer temperature and main voltage. DMX status: NC ER OK DMX is not connected swap 2 and 3 on the DMX cable DMX is OK DMX:216-OK DMX:216-NC T:37C 228V 230V 231V DMX:216-OK T:37C 228V 230V 231V DMX:216-OK DMX:216-ER T:37C 228V 230V 231V Temperature status: # Number shows the temperature of dimmer in C OL! Warning: The inside temperature of the dimmer is higher than 75 C. Outputs are switched off. DMX:216-OK T:37C 228V 230V 231V DMX:216-OK T:OL! 228V 230V 231V Rotate the ENCODER to see the output bargraph. DIMM OUT: Menu navigation: Press the ENCODER to enter the main menu. Rotate the ENCODER and select one of the following items by pressing it: ( 4 / 20)

1. START ADDRESS 2. PREHEAT 3. CURVE 4. AUTOMATIC TEST 5. LOCK CONTROLS 6. LIMIT OUTPUTS 7. SETUP /to enter the SETUP, press the ESC and ENTER buttons at the same time/ 1. DMX MODE 2. ANALOGUE MODE 3. MANUAL MODE 4. MIX MODE 5. PATCH 6. SCENE 7. LOST DMX 8. FACTORY RESET Set the DMX address SET DMX < 1 > START ADDRESS DMX START: <001> DMX ADDRESS - 001 - SAVED! Press the ENTER button. Rotate the ENCODER to set the DMX start address (001-512). Press the ENTER button to confirm. Preheat PREHEAT < 2 > EACH COMMON SET COMM.PREHEAT < +000 > SET COMM.PREHEAT SAVED! PREHEAT < 000 > - CHANNEL: 01 + SAVE SETTINGS? SAVED! Press the left button to select preheats for every channel individually or the right button to set one common preheat for all channels. If necessary, use preheat 0-100% for a fast control of the dimmer output. Dimmer curves CURVES < 3 > EACH COMMON SET COMMON CURVE < 0 > LINEAR COMMON CURVE - 0 - SET! SET COMMON CURVE < 1 > S-CURVE COMMON CURVE - 1 - SET! SET COMMON CURVE < 2 > LOG. COMMON CURVE - 2 - SET! SET COMMON CURVE < 3 > SWITCH COMMON CURVE - 3 - SET! < S-CURVE > - CHANNEL :01 + SAVE SETTINGS? SAVED! ( 5 / 20)

Press the left button to select the curves for each channel individually or the right button to set one common set of curves for all channels. Automatic lamp test AUTOMATIC < 4 > LAMP TEST DIMM OUT: Press the ENTER button to start the test. Every channel will be tested by increasing/decreasing the output value per channel. ( 6 / 20)

Lock Code LOCK: < 5 > SET CODE ENTER OLD CODE: <?000> ENTER NEW CODE: <?000> NEW LOCK CODE IS <1234> Enter the old code (factory setting is 0000). Press the ENCODER button. Enter a new code and press the ENCODER button. The new code is now saved. To lock the menu, press both buttons at the same time. To unlock the menu, press the ENCODER and enter the code. The menu is now unlocked. If you need to restore the code, please ask for service manual. Limits Press the left button to select the limit for each channel individually or the right button to set one common limit for all channels. Limit 100% means that output will go to 100%. Limit 50% means that outputs will go to 50% maximum. You can set the limit from 0-100%. Setup SETUP < 7 > PRESS PRESS Press the ESC and ENTER buttons at the same time to enter the SETUP MODE. The dimmer has six modes of control: DMX mode /controlled by DMX/ Analogue mode /controlled by 0-10V/ Manual mode /controlled by menu of dimmer/ Mix input mode /LTP or HTP rule/ Patch mode Scene control DMX mode SETUP: < 1 > DMX MODE DMX START: <001> DMX ADDRESS - 001 - SAVED! Rotate the ENCODER and set the DMX address (001-512). Press the ENTER button to confirm. The dimmer works only with the DMX input now. ( 7 / 20)

Analogue mode 0-10V SETUP: < 2 > ANALOG MODE SWITCH TO ANALOG ANALOG MODE SET Press the ENTER button. The dimmer works only with 0-10V control now. Manual mode SETUP < 3 > MANUAL MODE SWITCH TO MANUAL <02> 183: Press the ENTER button. The dimmer works only with manual control now. You can set output channel for each channel. Mix mode SETUP < 4 > MIX INPUT MODE MIX MODE: < 1 > OFF MIXED INPUT MODE!SWITCHED OFF! MIX MODE: < 2 > HTP MIXED INPUT MODE! SET TO HTP! MIX MODE: < 3 > LTP MIXED INPUT MODE! SET TO LTP! The dimmer is switched to the HTP or LTP mix mode now. In this mode, the dimmer is controlled via DMX and 0-10V input at same time. Patch mode SETUP < 5 > PATCH INPUT: OUT MANUAL:000 01 SAVE SETTINGS? SAVED! Press the right button to select the dimmer channel. Press the left button to select the control mode (DMX, analogue or manual mode) for each channel. Use the ENCODER to assign control mode for each channel. Scene mode SETUP < 6 > SCENE SCENE < 01 > ENABLE ENABLE SCENE? SCENE ENABLED SAVED! SCENE < 01 > DISABLE DISABLE SCENE? SCENE DISABLED SAVED! In menu scene, you can enable or disable the scene function. Press the ENTER button to confirm your selection. ( 8 / 20)

Flash scene SCENE < 02 > FLASH 12345678 FLASH:<12345678> - SCENE: 1 + SAVE SETTINGS? SAVED! FLASH:<2345678 > - SCENE: 1 + FLASH:<12345678> - SCENE: 1 + The flash scene is a scene mode, where scenes are called by a single press of a button. When any other button on the HLC is pressed, the other scene is called. You can preset up to 8 scenes. A scene that is to be flashed must be added to the Flash scene list. Rotate the ENCODER until you get to the desired scene number and confirm by the ENTER button. To remove a scene from the Flash scene list, rotate the ENCODER to the scene number and press the ESC button. A single press of the ENCODER saves all settings. Scene channel The channel for scene call from the DMX console (as if it was from analogue input) can be set here. The scene is called when the channel value is set to one of ten values. Scene numbers and their channel value ranges are illustrated in the table below. For example, to call scene 1, channel 13 can be used. The scene is called if fader is set in one of these values for more than 2 seconds. Value other than 0 blocks the scene call via analogue input, while value 255 cancels all scenes. Scene # Channel value range 1 10-19 2 20-29 3 30-39 4 40-49 5 50-59 6 60-69 7 70-79 8 80-89 9 90-99 10 100-109 11 110-119 12 120-129 13 130-139 14 140-149 15 150-159 Note: If the MIX INPUT MODE (SETUP <4>) is turned off, the selected channel does not cancel the scene call. ( 9 / 20)

Scene fade speed The fade speed can be set in three timeframes: SLOW, NORMAL or FAST. According to the setup, the scene will be changed to the selected speed when the scene is called. Save output of dimmer to scene The output of dimmer can be easily saved to any scene. This means that actual light output from dimmer can be saved to a scene and called later remotely. Select scene by rotating the ENCODER and save it by the ENTER button. This value will then be processed by a curve. If preheat on the channel is later changed, the scene will remain unchanged. Set up the scene manually Up to 15 scenes in the dimmer can be set up/recorded and their LATCH/FLASH function can be selected. Use ESC/ENTER button for scrolling over channels and the ENCODER for the selection of channel value and its confirmation. Then set up the output levels for each scene individually and confirm by pressing the ENTER button. DMX lost setup SETUP < 7 > LOST DMX LOST DMX: < 1 > DMX HOLD LOSS OF DMX DMX HOLD LOST DMX: < 2 > OUT TO 0% LOSS OF DMX SET TO 0% LOST DMX: < 3 > OUT TO 100% LOSS OF DMX SET TO 100% LOST DMX: < 4 > LOAD SCENE 01 SEL.SCENE < 01 > LOSS OF DMX LOAD SCENE 01 ( 10 / 20)

There are four options to set if the DMX signal from DMX port is disconnected: Outputs will hold the last DMX data frame. Outputs will fade to zero. Outputs will go to 100%. Outputs will be changed to a selected SCENE (0-15). Factory reset SETUP < 8 > FACTORY RESET RESET DEVICE? PLEASE WAIT FOR REBOOT The following are the factory defaults: DMX mode DMX start address: 001 Preheat: 000 Curve 01: linear Mixed mode: OFF Limits: 100% Lock code: 0000 Scene: disabled All scenes are erased Flash scene: 1-8 Latch scene: 9-15 Fade speed: NORM Lost DMX: hold active Service menu Contact your distributor or manufacturer to get the code to enter the service menu. In this menu, you are able to change the type of dimmer. You can set up the new lock code if the old one has been lost or calibrate the voltage metering and the global preheat. DDP S400 v.56 SRS LIGHT DESIGN Hold SERVICE CODE: <?000> Service menu 1. New code ENTER NEW CODE: <?000> NEW LOCK CODE IS <1234> Service menu 2. Calibration Cal. L1 (+002V) 228V 230V 231V SAVE SETTINGS? ESC ENTER SAVED! ESC ENTER Cal. L2 (+002V) 228V 230V 231V Cal. L3 (+002V) 228V 230V 231V Service menu 3. Channels Channels < 12 > ESC ENTER Channels < 12 > SAVED! Service menu 4. Preheat PREHEAT < 001 > ESC ENTER PREHEAT < 001 > SAVED! ( 11 / 20)

Menu tree ( 12 / 20)

Setup menu tree ( 13 / 20)

Technical data Dimming capacity DDPx1210 DDPx1213 DDPx1216 DDPx6025 DDPx6032 DDPx3025 DDPx3032 12x10A 12x2.3kW 12x13A 12x3kW 12x16A 12x3.7kW 6x25A 6x5.7kw 6x32A 6x7.3kW 3x25A 3x5.7kw 3x32A 3x7.3kW Dimensions & Housing: 482.5 x 132 x 420 mm, Steel housing with gray powder coating Weight: DDPx12xx: DDPx60xx: DDPx30xx: 29 kg 28 kg 27 kg Interference suppression: Phase-angle control with triacs and in-line precision filters: 400us Protection: Short circuit protection by MCB Optional 1P+N, 1P+1P short circuit protection Double thermal protection Ventilation: 100% duty cycle Temperature-controlled fan Automatic shutdown at critical temperatures Others: All safety features are displayed on the display Soft start Controlling of special functions via display, three keys and an encoder Circuit breakers on the front panel Easy change of power output connectors Display Functions: Voltage of all 3 phases Single channel values Inner temperature Load status check DMX signal status Digital menu functions: Preheat per channel Dimmer curve per channel Single channel patch Variable channel set DMX processing with fast output response Hold function for output in case of the DMX data failure ( 14 / 20)

Power Cable: H07RNF cable 5 x 4/6/10 mm 2 Inputs and Outputs: Pin out for the XLR connectors: Pin 1: Data CMN (not connected to earth) Pin 2: Data - Pin 3: Data + Pin 4, 5: Not connected The DMX Input and Output are wired in ratio 1:1. Pin out for the SUB-HD connector: Pins 1-12: Channels 1-12, analogue input (0-10V) Pins 13-14: DC - pole Pin 15: DC out +20V, 150mA Pin out for the K0 DDP12xx Terminal board for direct cable connection: Pin out for the K0 DDP60xx Terminal board for direct cable connection: ( 15 / 20)

Pin out for the SOCAPEX connectors: Output 1: Pin 1,3,5,7,9,11 Pin 2,4,6,8,10,12 Pins 13-19 Phase 1,2,3,4,5,6 Neutral Earth Output 2: Pin 1,3,5,7,9,11 Pin 2,4,6,8,10,12 Pins 13-19 Phase 7,8,9,10,11,12 Neutral Earth Pin out for the Harting/Ilme 24 connectors: Pins 1-12 Pins 13-24 Phases 1-12 Neutral Pin out for the Harting/Ilme 16 connectors /Type A phase + neutral/ Pins 1-6 Pins 9-14 Phases 1-6/7-12 Neutral ( 16 / 20)

Pin out for the Harting/Ilme 16 connectors /Type B phases + neutral inline/ Pin 1,3,5,7,9,11 Pin 2,4,6,8,10,12 Phases 1-6/7-12 Neutral Pin out for the 4x Harting/Ilme 16 connectors /wiring on request/ Pin out for the Ilme 6 connectors: Output 1: Pin 1,2,3 Pin 2,4,6 Phase 1,2,3 Neutral Output 2: Pin 1,2,3 Pin 2,4,6 Phase 4,5,6 Neutral Pin out for the 12x Socket /French, Schuko, UK, Danish, / ( 17 / 20)

Pin out for the 12x CEE16/3p type 17 socket Pin out for the 6x CEE32/3p socket Pin out for the 3x CEE32/3p socket ( 18 / 20)

Declaration of conformity We hereby declare that the equipment described below conforms to its design, type and version introduced by us to the fundamental safety and health requirements of the EU Guidelines Machines. Manufacturer: SRS Group Rybničná 36/D 83106 Bratislava Slovakia Declares that the product Name of product: Type/version: Digital dimmer pack series400 DDP12xx, DDPN12xx Correspond to the specification: EN 60-950-1:2003 EN 55103-1:2000 EN 55103-2:2000 EN 60-598-2-17 1989 including amendments 1/2 EN 60-598-1 1992 including amendment 1 CE marking directive 93/68 EEC Low voltage directive (2006/95/EG) EMC directive (2004/108/EWG) Bratislava, 29 April 2011 Robert Sloboda ( 19 / 20)

Copyright 2017 SRS Group, s.r.o. Specifications subject to change without notice. Document: DDP12XX_en_manual_M018.doc Version 4.0 Actual as of: 6 July 2018 SRS Group s.r.o. Rybnicna 36/D 831 07 Bratislava Slovakia Phone: +421 2 44 681 417 Fax: +421 2 4468 1419 Email: sales@srs-group.com www.srs-group.com ( 20 / 20)