Allen-Bradley 1492-RCDA4A40

Similar documents
1492-SP Supplementary Protectors

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection

Control Circuit and Load Protection Products

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

TeSys IEC Contactors and Overload Relays

Allen-Bradley 700-K40E-DJ

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Supplementary Circuit Protectors Type GSB63

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

ALLEN BRADLEY RELAY Bulletin 700-HF

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Bulletin 700-HL 2-Pole Terminal Block Relay

Cat. No. (Spring Clamp. Input Voltage

Introduction Circuit Protection

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Bulletin 1489 Circuit Breakers. Selection Guide

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Motor protection relays

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

60103 Circuit Breaker

Miniature Circuit Breakers and Supplementary Protectors. Contents

Section 4 Ground-Fault Protection Devices

Combined RCD/MCB Devices FRBmM, 1+N-pole

CS8 Industrial Control Relays

Complete UL/CSA Disconnect Switch Kits

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Residual Current Devices drcm Digital

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

9926 Series Branch Rated Circuit Breakers AC Version

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Square D General Purpose Relays

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Product Guide. UL 489 DIN rail miniature circuit breakers

Allen-Bradley Drives

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Jtec 10kA Miniature Circuit Breaker

Bulletin 700-HA Tube Base Relay

Disconnect Switches. Safe Switching and Disconnecting

Bulletin 817 Thermistor Protection Relay

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Digital ac/dc (24V) Input Module

DSE201, DSE201 M Compact design with enhanced protection

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Product Guide. UL 1077 DIN Rail Supplementary Protectors

MULTI 9 System Catalog

E-STOP relays, safety gate monitors

Digital ac/dc (24V) Input Module

ic60n RCBO 30 ma IEC , IEC , AS/NZS

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Electronic timer CT-ARS.11

Add-on Residual Current Protection PBSM MW

MINI-PS AC/10-15DC/8

Installation Instructions

Motor protection circuit breakers

PanelView Plus/VersaView CE Terminals and Display Modules

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

140M C 2 E A63 KN CC GJ

Horizontal distribution busbar HX 3 80/125 A plug-in

Surge & Filter Protection Addressing your industrial power quality needs.

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

ITEM ESM-BA301

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

CompactBlock Guard I/O EtherNet/IP Safety Modules

Multi 9 System Catalog

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Transcription:

Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps prevent wiring misses Test push button to verify device functionality Indicator window reflects contact state red: closed; green: open Scratch- and solventresistant printing IP20 finger-safe design (all sides) Accepts right-mounted auxiliary and signal contacts The Bulletin 1492-RCD line includes Residual Current Devices, also known as Residual Current Circuit Breakers, for detecting and interrupting leakage current to ground. By detecting small leakage currents and disconnecting all ungrounded connectors quickly, RCDs can prevent injury to exposed personnel and damage to equipment. RCDs are used in series with miniature circuit breakers for additional circuit protection from not only overload and short circuit, but also ground fault. Many short circuits begin as undetected ground faults. Using an RCD in an application may detect problems before costly equipment damage and downtime occurs. These devices are Type A Residual Current Devices to IEC Standards. Features Provides protection against current leakage to ground (earth) caused by an insulation loss between a live conductor and an exposed conductive part (such as an abraded wire, or a grounded person touching the live conductor) Suitable for protection against AC and pulsating DC (rectified AC) earth leakage current 30 ma sensitivity devices for personnel protection (consult local requirements) 100, 300 and 500 ma sensitivity devices for equipment protection Dual terminals allow a more secure connection of two wires, or both a wire and bus bar Reversible line and load connections 1492-RCD Residual Current Devices Current Ratings Rated Sensitivity I n Poles 2, 4 Standards Compliance Certifications 25, 40, 63, 80 A 30, 100, 300, 500 ma UL 1053 ANSI/NFPA 70 EN 61008 CSA C22.2 No.144 GB 16916 curus Recognized, File No. E53935 RoHS Compliant Allen-Bradley 1492-RCDA4A40 85

Catalog Number Explanation Note: Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; some combinations may not produce a valid catalog number. 1492 - RCDA 2 A 25 a b c d e a Type Code Description RCDA Residual Current Device, Type A b Poles Code Description 2 2-Pole 4 4-Pole c Sensitivity I n Code Rated Sensitivity [ma] A 30 B 100 C 300 D 500 d Rated Current (I n ) Code Current [A] 25 25 40 40 63 63 80 80 e Delay Option (available on select 4-pole devices) Code Description Can be left blank S With Delay 86

Product Selection 4-Pole (3-Pole + Neutral) Sensitivity (ma) Rated Current (A) 2-Pole (1-Pole + Neutral) Standard With Delay 25 1492-RCDA2A25 1492-RCDA4A25 30 40 1492-RCDA2A40 1492-RCDA4A40 63 1492-RCDA4A63 80 1492-RCDA4A80 25 1492-RCDA2B25 1492-RCDA4B25 100 40 1492-RCDA2B40 1492-RCDA4B40 1492-RCDA4B40S 63 1492-RCDA4B63 1492-RCDA4B63S 25 1492-RCDA2C25 1492-RCDA4C25 300 40 1492-RCDA2C40 1492-RCDA4C40 1492-RCDA4C40S 63 1492-RCDA4C63 1492-RCDA4C63S 80 1492-RCDA4C80 25 1492-RCDA4D25 500 40 1492-RCDA4D40 63 1492-RCDA4D63 80 1492-RCDA4D80 Diagram Allen-Bradley 1492-RCDA4A40 87

Specifications General Data Poles 2,4 Rated currenti n Rated sensitivity I n Rated short-circuit strength 2-pole 4-pole Rated operational voltage U e per IEC/EN Rated voltage U e per UL Max. operating voltage of circuit test Min. operating voltage of circuit test Rated frequency Electrical Ratings 25, 40, 63, 80 A 30, 100, 300 ma 30, 100, 300, 500 ma 10 ka with 63 A gg/gl back-up fuse, 10 ka with 80 A gg/gl back-up fuse for 80 A device 230/400V AC 480Y/277V AC 254V AC 110V 50/60 Hz Rated conditional short-circuit 10 ka (SCPD - fuse gg 100 A) Rated residual breaking capacity Rated impulse withstand voltage U imp (1.2/50µs) Dielectric test voltage at ind. freq. for 1 min. Electrical endurance Indicator window Protection degree Housing Terminals Ambient temperature (with daily average +35 C) Mechanical Environmental 1 ka 4 kv 2.5 kv 10,000 operations Red ON/green OFF IP4X IP2X -25...+55 C Storage temperature -40...+70 C Mechanical endurance Terminal type Cross-section of wire - solid, stranded, flexible (front/back terminal slot) Cross-section of bus bars (front/back terminal slot) Tightening torque Mounting Supply 25...63 A 80 A Installation 20,000 operations Dual terminal 25/25 mm 2 18...4 AWG 35/35 mm 2 18 2 AWG 25...63 A 10/10 mm 2 80 A 16/16 mm 2 25...63 A 80 A 2.8 N m 25 in lb 4.8 N m 43 in lb DIN Rail EN 60715 (35 mm) with fast clip device Optional Approximate Dimensions and Weight Dimensions (H x D x W) 2-pole 88 x 67 x 35 mm 4-pole 88 x 67 x 70 mm Weight 2-pole 200 g (7.1 oz.) 4-pole 350 g (12.3 oz.) Combination with Auxiliary Elements Auxiliary contact Yes Signal contact Yes Power Loss Due to Current Power Loss [W] Rated Current [A] 2-pole 4-pole 25 1 1.3 40 2.4 3.2 63 3.2 4.4 80 8.8 33.3 88

Approximate Dimensions Note: Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 88 mm (3.5 ) 35 mm (1.4 ) 70 mm (2.8 ) 75 mm (3.0 ) 67 mm (2.6 ) 2-, 4-Pole 2-Pole 4-Pole Allen-Bradley 1492-RCDA4A40 89

Accessories Right Mount Photo Product Description Contacts Standards Certifications Auxiliary/Signal Contact Auxiliary Contact 1 N.O./N.C. (1 C.O.) UL 1077 98 96 CSA 22.2 No. 235 EN 60947-5-1 95 GB 14048.5 1 N.O./N.C. (1 C.O.) UL 1077-4 - 1-2 1-2- 3-1 N.O. + 1 N.C. -1-2 -4 1-2 - - 1 2 N.C. -3-2 - 2 1-2 - 2 N.O. -1-3 -3-4 -4 1-2 - CSA 22.2 No. 235 EN 60947-5-1 GB 14048.5 UL 1077 CSA 22.2 No. 235 EN 60947-5-1 GB 14048.5 UL 1077 CSA 22.2 No. 235 EN 60947-5-1 GB 14048.5 UL 1077 CSA 22.2 No. 235 EN 60947-5-1 GB 14048.5 UL Recognized CSA Certified UL Recognized CSA Certified UL Recognized CSA Certified UL Recognized CSA Certified UL Recognized CSA Certified UL/CSA Max. Current/Voltage 1 A @ 480V AC 2 A @ 277V AC 1.5 A @ 125V DC 2 A @ 60V DC 4 A @ 24V DC 1 A @ 480V AC 2 A @ 277V AC 1.5 A @ 125V DC 2 A @ 60V DC 4 A @ 24V DC 1 A @ 400V AC 2 A @ 230V AC 1 A @ 50V DC 2 A @ 30V DC 1 A @ 400V AC 2 A @ 230V AC 1 A @ 50V DC 2 A @ 30V DC 1 A @ 400V AC 2 A @ 230V AC 1 A @ 50V DC 2 A @ 30V DC IEC Ratings Current/Voltage 2 A @ 230V (AC-14) 1 A @ 400V (AC-14) 1.5 A @ 110V (DC-12) 1 A @ 220V (DC-12) 4 A @ 24V (DC-13) 2 A @ 60V (DC-13) 2 A @ 230V (AC-14) 1 A @ 400V (AC-14) 1.5 A @ 110V (DC-12) 1 A @ 220V (DC-12) 4 A @ 24V (DC-13) 2 A @ 60V (DC-13) 2 A @ 230V (AC-14) 1 A @ 400V (AC-14) 2 A @ 30V (DC-12) 1 A @ 50V (DC-12) 2 A @ 30V (DC-13) 1 A @ 50V (DC-13) 2 A @ 230V (AC-14) 1 A @ 400V (AC-14) 2 A @ 30V (DC-12) 1 A @ 50V (DC-12) 2 A @ 30V (DC-13) 1 A @ 50V (DC-13) 2 A @ 230V (AC-14) 1 A @ 400V (AC-14) 2 A @ 30V (DC-12) 1 A @ 50V (DC-12) 2 A @ 30V (DC-13) 1 A @ 50V (DC-13) Cat. No. 189-ASCR3 189-AR3 189-AR11 189-AR02 189-AR20 A maximum of one C.O. type signal contact, and one C.O. type auxiliary contact OR two C.O. type auxiliary contacts may be installed per 1492-RCD. A maximum of one 189-AR11, -AR02, or -AR20 auxiliary contact may be installed per 1492-RCD. They may not be combined with C.O. type contacts. A maximum of three accessories of any type may be installed per 1492-RCD. The signal contact must be mounted closest to the RCD, then the auxiliary contact(s). For allowed combinations, and installation instructions please contact your local Rockwell Automation sales office or Allen-Bradley distributor. 90

Accessory Approximate Dimensions Note: Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 8.8 mm (0.35 ) 85 mm (3.35 ) 74 mm (2.91 ) 189-ASCR3 8.8 mm (0.35 ) 85 mm (3.35 ) 74 mm (2.91 ) 189-AR3 8.8 mm (0.35 ) 85 mm (3.35 ) 74 mm (2.91 ) 189-AR11, 189-AR02, 189-AR20 Allen-Bradley 1492-RCDA4A40 91

Bus Bars 1492-RCD Cuttable Bus Bars Cat. No. Description Pins Pkg. Qty. 2-Phase MCB to RCD 4 10 189-CL204 4-Phase MCB to RCD 8 10 189-CL408 These devices are, but not certified to any UL, CSA, or other standard. 1492-RCD Bus Bar Accessories Cat. No. Description Pkg. Qty. Terminal Power Feed, 6...25 mm 2 10 189-CLT25 Terminal Power Feed, 6...50 mm² 10 189-CLT50 Dedicated Power Feed, 50 mm² 10 189-CLT50D For 2-phase bus bar 10 189-CL3EC For 4-phase bus bar 10 189-CL4EC Protective Shroud for unused pins 10 189-CLPS These devices are, but not certified to any UL, CSA, or other standard. 189-CL3EC also used for 2- and 3-phase MCB bus bars. 1492-RCD 2.4 Nm (21 lb in) 92

Bus Bar Approximate Dimensions Note: Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 2- and 4-Phase Bus Bars 4 mm (0.16 ) 17.6 mm (0.69 ) 3 x 17.6 = 52.6 mm (3 x 0.69 = 2.21 ) 9.8 mm (0.39 ) 1 mm (0.04 ) 29 mm (1.14 ) 19.2 mm (0.76 ) 14.8 mm (0.58 ) 72 mm +2 (2.83 ) +2 189-CL204 4 mm (0.16 ) 17.6 mm (0.69 ) 7 x 17.6 = 123.2 mm (7 x 0.69 = 4.85 ) 11.5mm (0.45 ) 1 mm (0.04 ) 30.5 mm 19 mm (1.20 ) (0.75 ) 19.3 mm (0.76 ) 148 mm +2 (5.82 ) +2 189-CL408 Allen-Bradley 1492-RCDA4A40 93

17 mm (0.67 ) 8 mm (0.31 ) 1492-RCD Residual Current Devices Bus Bar Accessory Approximate Dimensions Note: Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 7 mm (0.27 ) 4.3 mm (0.17 ) 2 mm (0.08 ) 11 mm (0.43 ) 4.3 mm (0.16 ) 2 mm (0.08 ) 15 mm (0.59 ) 15 mm (0.59 ) 32.5mm (1.28 ) 35 mm (1.38 ) 13 mm (0.51 ) 16.5 mm (0.65 ) 13 mm (0.65 ) 25.6 mm (1.01 ) 189-CLT25 189-CLT50 12.3 mm (0.48 ) 29.8 mm (1.17 ) 28.8 mm (1.13 ) 12 mm (0.47 ) 13.9 mm (0.55 ) 17.75 mm (0.70 ) 35.3 mm (1.39 ) 10.5 mm (0.41 ) 18 mm (0.71 ) 3.6 mm (0.14 ) 189-CLT50D 189-CL3EC 23.7 mm (0.93 ) 3.5 mm (0.14 ) mm 5 ) 13.5 mm (0.53 ) 4.3 mm (0.17 ) 84.7 mm (3.33 ) 4.2 mm (0.17 ) 18.5 mm (0.73 ) 3.5 (0. 17.8 mm (0.70 ) 4 x 17.8 = 71.2 mm (4 x 0.70 = 2.80 ) 11.6 mm (0.46 ) 189-CL4EC 189-CLPS 94