Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Similar documents
US Catalog March Surge protective devices (SPDs) UL range

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Surge Protection Devices Type 1+2

Surge Protection Devices and Surge Protection Kit

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Autoprotected Surge Arresters New OVR Plus range

Surge Protection Devices Ex9UE2

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection

Overvoltage Protection Devices

ETITEC - Lightning and Surge Arresters

Type of surge arrester

Overvoltage Protection Devices

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Reliability in Surge Protection. Photovoltaic Systems.

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

wietap wietap Overvoltage Protection Tensions running high

Cirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Modular surge protective devices (SPDs)

Surge & Filter Protection Addressing your industrial power quality needs.

Lightning and Surge Arresters

3 Design of the electrical installation protection system

Modular surge protective devices (SPDs)

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Modular surge protective devices (SPDs) Cat. Nos :

L*W*H:120*65*35.5 L*W*H:152*133*48 L*W*H:220*143*48 L*W*H:360*280*132 for 1ph 5A~10A for 1ph 10A~16A for 1ph 20A~45A for 1ph 50A~120A/200kA

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

2 Principle of lightning protection

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Modular surge protective devices

Surge Protective Device

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks

ENGR. MARITES R. PANGILINAN, P.E.E.

Lightning Current Equipotential Bonding SPDs

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Building Surge Protection Information Pack

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

Surge Protection for Surveillance Systems

VAL-CP-3S-350. Extract from the online catalog. Order No.:

DSE201, DSE201 M Compact design with enhanced protection

Coordination of Surge protection devices

SPD Catalogue. SPD Catalogue. for AC applications

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

Surge Protection Solutions

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

OPTIMISED LUMINAIRE PROTECTION

Surge Protective Devices OVR Series - Enclosed SPD Mining and Aggregates

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Lightning & Surge Protection

NEW surge protective devices

Lightning & Surge Protection for Wind Turbine Systems

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

OPTIMISED LUMINAIRE PROTECTION

BS th Edition wiring regulations Furse overview

PT 3-PB-ST. Extract from the online catalog. Order No.:

Lightning & Surge Protection

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Installation / Control Technique

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

Surge Protection for Low Voltage Power Systems

QUINT-PS/ 1AC/24DC/ 5

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

CONNECT AND PROTECT. nvent ERICO Critec SRF N-Series. Surge Reduction Filters

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

Remote contact signaling available. visual status indication

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

QUINT-PS AC/24DC/10

R3&A Limited, Cobourg, ON

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations

Product Overview Surge Protective Devices

US CATALOG SMISSLINE TP

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

ELECTRONICS Electronics

Surge Protective Device

PV protective solutions

Datasheet Stock No: RS Pro

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

US Catalog July 2016 SMISSLINE TP

Overvoltage Protection for low-voltage supplies

CARLO GAVAZZI Automation Components. Surge Protection Devices

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Lightning and Surge Protection for PV Systems

ic60n RCBO 30 ma IEC , IEC , AS/NZS

Company Profile Surge Protective Devices

Surge Protection Devices OVR series

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

Lightning and Surge Arresters

Transcription:

Type 1 & Type 1+2 TECHNICAL FEATURES Technology Type 1 OVR T1 2 TS Triggered spark-gap Electrical features Standard IEC 61643-1 / EN 61643-11 Type / test class 1 / I Poles 1P - 1P -, 2P 2L 3P 3L 4P 4L 1P+N 1N 3P+N 3N Types of networks IT - TNS TNS-TNC TNC TNS TT - TNS TT - TNS Type of current A.C. Nominal voltage Un (L-N/L-L) V 400 230 230/400 230/400 230/400 Max. cont. operating voltage Uc V 440 2 - - Max. cont. operating voltage Uc (L-N / N- ) V - - 2 / 2 2 / 2 Impulse current Iimp (10/30) per pole ka 2 2 - - Impulse current Iimp (10/30) (L-N / N- ) ka - - 2 / 0 2 / 100 Imax discharge current (8/20) per pole (Imax) ka - - - - Imax discharge current (8/20) (L-N/N-terre) (Imax) ka - - - - Nominal discharge current In (8/20) ka 2 2 2 2 Voltage protection level Up kv 2 2. - - Voltage protection level Up (L-N / N- ) kv - - 2. / 2 2. / 2 Follow current interrupting rating If i karms 0 0 - - Follow current interrupting rating If i (L-N / N- ) karms - - 0 / 0.1 0 / 0.1 TOV (Temporary overvoltage) withstand U T (s.) V 690 400 - - TOV (Temporary overvoltage) withstand U T (L-N: s. / N- : 200ms.) V - - 400 / 1200 400 / 1200 Continuous operating current Ic ma None Short-circuit withstand capability karms 0 Load current I load (for V-wiring) A 12 Maximum back-up fuse gg/gl - Parallel Connection A 12 Serial Connection (V-wiring) A 12 Mechanical features Stocking and operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 V0 Colour of Housing Polyarylamide grey RAL 703 State indicator Option (with TS) TS remote indicator Option (TS) Wire range (L, N, ) solid wire mm 2 2.... 0 stranded wire mm 2 2.... 3 Stripping length (L, N, ) mm 1 Tightening torque (L, N, ) Nm 3. TECHNICAL FEATURES OF THE INTEGRATED AUXILIARY CONTACT (TS) Electrical features Contact complement 1NO (1 normally open contact), +1NC (1 normally closed contact) Min. load 6 V D.C. - 10 ma Max. load 20 V A.C. - A Continuous operating current ma 10 Connection cross-section mm 2 1. /2 ABB

Type 1 & Type 1+2 Type 1 Type1+2 Type 1+2 Type 1+2 OVR T1 2 2-7 OVR T1+2 2 2 TS OVR T1+2 1 2-7 OVR T1+2 7 27 s P Triggered spark-gap Triggered spark-gap/varistor Triggered spark-gap Varistor IEC 61643-1 / EN 61643-11 IEC 61643-1 / EN 61643-11 IEC 61643-1 / EN 61643-11 IEC 61643-1 / EN 61643-11 1 / I 1/ I 1 / I 1 / I 1P - 3P+N 3N 1P - 3P+N 3N 1P - 3P 3L 4P 4L 1P+N 1N 3P+N 3N TNS-TNC TT - TNS TNS - TNC TNS-TNC TT - TNS TNS-TNC TNC TNS TT - TNS TT - TNS A.C. A.C. A.C. A.C. 230/400 230 230 230/400 230 230/400 230/400 230/400 2-2 2-27 27 27 / 2-2 / 2 - - 2 / 2 2-2 1-7 - - - 2 / 100 - - 1 / 0-7 / 12. 7 / 12. - - 60 60 60 70 - - - 70/70 70/70 2 2 1 6 6 6 2. - 1. 1. - 0.9 - - - 2. / 1. - - 1. / 1. - 0.9 / 1.4 0.9 / 1. 7-1 7 - NA - - - 7 / 0.1 - - 7 / 0.1 - NA / 0.1 NA / 0.1 60-334 60-334 - - - 60 / 1200 - - 60 / 1200-334 / 1200 < 2 (LED) < 1 (Varistor leakage) < 2 (LED) < 1 0 0 0 0-12 - - 12 12 12 0 NA 12 NA NA -40 to +80-40 to +80-40 to +80-40 to +80 IP 20 IP 20 IP 20 IP 20 V0 V0 V0 V0 Polyarylamide grey RAL 703 Polyarylamide grey RAL 703 Polyarylamide grey RAL 703 PC grey RAL 703 Yes Yes Yes Yes No Yes No No 2.... 0 2.... 0 2.... 0 2.... 2 2.... 3 2.... 3 2.... 3 2.... 16 1 1 1 12. 3. 3. 3. 2.8-1NO (1 normally open contact), - - - +1NC (1 normally closed contact) - 12V D.C. - 10 ma - - - 20V A.C. - 1 A - - - None - - - 1. - - ABB /3

Type 2 TECHNICAL FEATURES Technology Type 2 (pluggable) OVR T2 (s) P (TS) Varistor Electrical features Standard IEC 61643-1 / EN 61643-11 Type / test class 2 / II Poles 1P - 3P 3L 4P 4L 3P+N 3N 1P - 3P3L 4P4L 1P+N 1N 3P+N 3N Types of networks IT - TNS IT* IT TT - TNS TNS-TNC TNC TNS TT-TNS TT-TNS Type of current A.C. A.C. A.C. A.C. A.C. Nominal voltage Un (L-N/L-L) V 400 230/400 230/400 230 230 400 230 230/400 Max. cont. operating voltage Uc V 440 440-27 - Max. cont. operating voltage Uc (L-N / N-PE) V - - 440 / 2-27 / 2 Max. cont. operating voltage Ucpv V Maximum discharge current Imax (8/20) per pole ka 1 40 70 40 70 - - - 1 40 70 - - - Maximum discharge current Imax (8/20) (L-N / N-PE) ka 1 /70 40 /70 70 /70 - - - 1 /70 40 /70 70 /70 Nominal discharge current In (8/20) ka 20 30 20 30 20 30 20 30 20 30 Nominal discharge current In (8/20) (L-N / N-PE) ka /30 20/30 30/30 - - - /30 20/30 30/30 Voltage protection level Up kv 1. 1.9 2 1.9 2 - - - 1 1.4 1. - - - Voltage protection level Up (L-N / N-PE) kv 1./1.4 1.9/1.4 2/1.4 - - - 1/1.4 1.4/1.4 1./1.4 Residual voltage Ures at 3 ka per pole kv 1.4 1.4 1.3 1.4 1.3-0.9 0.9 0.8 - Residual voltage Ures at 3kA (L-N / N-PE) kv 1.4/1.2 1.4/1.2 1.3/1.2-0.9/1.2 0.9/1.2 0.8/1.2 Follow current interrupting rating If i karms NA NA - NA - Follow current interrupting rating If i (L-N / N-PE) karms - - NA / 0.1 - NA / 0.1 TOV (Temporary overvoltage) withstand Ut (s.) V 440 440 440 440-334 - TOV (Temporary overvoltage) withstand Ut (L-N: s./n-pe: 200ms) V - - 440 / 1200-334 / 1200 Continuous operating current Ic ma < 1 < 1 < 1 < 1 < 1 Short-circuit withstand capability karms 0 0 0 0 0 Short-circuit D.C. current withstand capability Iscwpv A Disconnector gg -gl fuse A 0 0 0 0 0 curve C circuit breaker A 0 0 0 0 0 Mechanical features Stocking and operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 V0 Material of Housing PC grey RAL 703 Pluggable cartridge Yes Integrated thermal disconnector Yes State indicator Yes Safety reserve Option (s) TS remote indicator Option (TS) Wire range (L, N, ) solid wire mm 2 2.... 2 stranded wire mm 2 2.... 16 Stripping length (L, N, ) mm 12. Tightening torque (L, N, ) Nm 2.8 TECHNICAL FEATURES OF THE INTEGRATED AUXILIARY CONTACT (TS) Electrical features Contact complement 1NO (1 make contact), +1NC (1 normally closed contact) Min. load 12V D.C. - 10 ma Max. load 20V A.C. - 1 A Continuous operating current ma None Connection cross-section mm 2 1. /4 ABB

Type 2 Type 2 (non pluggable) Type 2 (non pluggable) OVR Plus N1 40 OVR Plus N3 1 OVR Plus N3 40 OVR T2 27 Varistor IEC 61643-1 / EN 61643-11 EN 61643-11, IEC 61643-1 EN 61643-11, IEC 61643-1 IEC 61643-1 / EN 61643-11 2 / II T2/II T2/II 2 / II 1P+N N1 4 4 1P - 4P 4L TT - TNS TT-TNS TT-TNS TNS - TNC TNS A.C. A.C. A.C. A.C. 230/400 230/400 230/400 230 230/400 320 320 320 27 - - - - 20 40 20 / 40 1/60 40/60 - - - - - 20 20 /40 20/40 - - - - - 1 1.4 1.6 / 1. 1.3/1. 2/1. - - - - - 1 0.9 1/0.6 1.1/1 1.1/1 - - NA - - NA - - - - - - - 334-334/1200 334/1200 - < 1 <0.1 <0.1 < 1 1 10 1 0 Integrated MCB Integrated MCB Integrated MCB - 0-0 -40 to +80-40 to +80 IP 20 IP 20 V0 V0 PC grey RAL 703 PC grey RAL 703 No No No No Yes Yes Yes Yes Yes (MCB) Yes (MCB) Yes (MCB) Yes No No No No Optional (S2C-H6R) Optional (S2C-H6R) Optional (S2C-H6R) ABB (2CDS200912R0001) ABB (2CDS200912R0001) ABB (2CDS200912R0001) No 2.... 2 2. 2 2. 2 2.... 2 2.... 16 2. 16 2. 16 2.... 16 11 11 11 12. 2.8 2,8 2,8 2,8 ABB /

Type 2 NEW TECHNICAL FEATURES Type 1 Photovoltaic OVR PV T1 6.2 xx P TS Technology Varistor Electrical features Standard IEC 61643-1 / EN 61643-11 / UTE 61740-1 / pren 039-11 Type / test class T1/I Poles 9 Types of networks Photovoltaic Type of current V D.C. Nominal voltage Un (L-N/L-L) V 600 1000 Max. cont. operating voltage Uc V - - Max. cont. operating voltage Ucpv V 670 1000 Impulse current Iimp (10/30) per pole ka 6,2 6,2 Maximum discharge current Imax (8/20) per pole ka - - Nominal discharge current In (8/20) ka 6,2 6,2 Voltage protection level Up kv 1.9 / 1.9 2. / 2. Follow current interrupting rating Ifi ka - - TOV (Temporary overvoltage) withstand Ut (s.) V - - TOV (Temporary overvoltage) withstand Ut (L-N: s./n-pe: 200ms) V - - Response time ns <2 <2 Series resistance Ω - - Cut frequency MHz - - Continuous operating current Ic ma <0.1 <0.1 Short-circuit withstand capability ka - - Short-circuit D.C. current withstand capability Iscwpv A 100 Disconnector If Iscwpv>100A fuse A 10AgPV (E90PV) circuit breaker A - - Mechanical features Stocking and operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 VO Material of Housing PC grey RAL 703 Pluggable cartridge No No Integrated thermal disconnector Yes Yes State indicator Yes Yes Safety reserve No No TS remote indicator Yes Yes Wire range (L, N, ) solid wire mm² 2. 2 stranded wire mm² 2. 16 Stripping length (L, N, ) mm 12,2 12,2 Tightening torque (L, N, ) Nm 2, 2, TECHNICAL FEATURES OF THE INTEGRATED AUXILIARY CONTACT (TS) Electrical features 1 NO - 1 NC 1 NO - 1 NC Contact complement Min. load 12 V DC - 10 ma 12 V DC - 10 ma Max. load 20 V AC - 1 A 20 V AC - 1 A Connection cross-section mm² 1, 1, /6 ABB

Type 2 Type 2 Photovoltaic OVR PV 40 xx P (TS) Telecom / Dataline OVR TC xx V P Varistor IEC 61643-1 / EN 61643-11 / UTE 61740-1 / pren 039-11 IEC 61643-21 T2/II C2 3 1 pair Photovoltaic RS RS 232 4/20 ma RNIS ADSL ADSL 422/48 D.C. D.C. 600 1000 6 12 24 48 200FR 200 - - 7 14 27 3 220 220 670 1000-40 40 10 20 20 - - 1 20 3 70 400 700 - - - - - - <2 <2 <1 <100 - - 10 na - - 10 2 4 6 3 na <0.0 <0.0 140 na - - - 100 If Iscwpv>100A 10AgPV (E90PV) - S802PV-S10 S804PV-S10 - -40 to +80 IP 20 VO PC grey RAL 703 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - Yes Yes - No No No No No No No No Yes (TS option) Yes (TS option) No No No No No No 2. 2 1, 2. 16 6 12,2 12,2 7 2, 2, 0,4 1 NO - 1 NC 1 NO - 1 NC - - 12 V DC - 10 ma 12 V DC - 10 ma - 20 V AC - 1 A 20 V AC - 1 A - 1, 1, - ABB /7

Selection tables T1 2CSC400313F0201 2CSC400313F0201 2CSC400316F0201 2CSC40031F0201 2CSC40031F0201 2CSC400306F0201 Surge Protective Devices, Type 1 / Type 1+2 Function: Type 1 and Type 1+2 are Lightning Current Arresters. They can handle and divert high energy from lightning. They are necessary when the installation is exposed to direct lightning (for example when the building is equipped with external lightning protection system or powered by aerial lines). They shall be installed at the line entrance of the installation (meter board or main distribution board). ABB Type 1 and Type 1+2 are tested with wave-shape 10/30. Additionnaly, Type 1+2 are also tested with wave-shape 8/20 to guarantee protection against overvoltage of low energy from remote lightning stroke or from switching operations. ABB Type 1+2 feature a better voltage protection level (Up) than Type 1 which make them suitable for protection of most of electrical and electronic equipment. Type 1 Neutral are for TT networks when used in combination with phase Type 1 or Type 1+2. Application: residential, commercial, industrial Standard: IEC 61643-1 / EN 61643-11 10/30 current wave for Type 1, 10/30 & 8/20 for Type 1+2, spark-gap technology (no blow-out). Nb. of Impulse Follow Voltage Nominal Max. cont. Order Bbn Price Price Weight Pack poles current current protection voltage operating details 3660308 1 piece group 1 piece unit Iimp interrupting level voltage (10/30) If i Up Un Uc ka karms kv V V Type code Order code EAN kg pc. Type 1 (Ifi = 0 ka) TNS, TNC 1 2 0 2. 230 2 OVR T1 2 2 2CTB81101R0100 10877 0.2 1 IT, TNC 1 2 0 2 400 440 OVR T1 2 440-0 2CTB81101R9300 14929 0.27 1 TNS 2 2 (2) 0 2. 230 2 OVR T1 2L 2 2 2CTB81101R1200 10891 0.0 1 2 2 (2) 0 2. 230 2 OVR T1 2L 2 2 TS (3) 2CTB81101R1100 1094 0.60 1 TT (1 Ph+N), TNS 1+N 2/0 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 1N 2 2 2CTB81101R100 10921 0.0 1 1+N 2/0 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 1N 2 2 TS (3) 2CTB81101R1000 10976 0.60 1 TNC 3 2 (2) 0 2. 230 2 OVR T1 3L 2 2 2CTB81101R1300 10907 0.7 1 3 2 (2) 0 2. 230 2 OVR T1 3L 2 2 TS (3) 2CTB81101R0600 1092 0.8 1 TNS 4 2 (2) 0 2. 230 2 OVR T1 4L 2 2 2CTB81101R1400 10914 1.00 1 4 2 (2) 0 2. 230 2 OVR T1 4L 2 2 TS (3) 2CTB81101R0800 10969 1.10 1 TT (3 Ph+N), TNS 3+N 2/100 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 3N 2 2 2CTB81101R1600 10938 1.00 1 3+N 2/100 (1) 0/0.1 (1) 2./2 (1) 230 2/2 (1) OVR T1 3N 2 2 TS (3) 2CTB81101R0700 10983 1.10 1 (1) L-N / N-. (2) per pole. (3) TS: telesignal contact for remote control of the status of the Surge Protective Device. Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ /8 ABB

Selection tables T1 2CSC400297F0201 Nb. of Impulse Follow Voltage Nominal Max. cont. Order Bbn Price Price Weight Pack poles current current protection voltage operating details 3660308 1 piece group 1 piece unit Iimp 7% level voltage (10/30) If i Up Un Uc ka karms kv V V Type code Order code EAN kg pc. Type 1 (Ifi = 7 ka) TNS, TNC 2CSC400299F0201 1 2 7 2. 230 2 OVR T1 2 2-7 2CTB81101R8700 14110 0.12 1 TT (3 Ph+N), TNS 3+N 2/100 (1) 7/0.1 (1) 2./1. (1) 230 2/2 (1) OVR T1 3N 2 2-7 2CTB81101R8800 14127 0.60 1 OVR HL (Type 1 with varistors) T1+T2 1N 4L T1 (N+PE) 2CSC400306F0201 2CSC400299F0201 2CSC400299F0201 2CSC400297F0201 2CSC400300F0201 2CSC400299F0201 TT, TNS, TNC, IT 1 1 NA 1.4 400 440 OVR HL 1 440 s P TS 2CTB81201R0800 09802 0.2 1 2 1 NA 1.4 400 440 OVR HL 2L 1 440 s P TS 2CTB81303R0400 09826 0. 1 Type 1+2 (Iimp = 2 ka) TNS, TNC 1 2 1 1. 230 2 OVR T1+2 2 2 TS (3) 2CTB81101R0300 10884 0.30 1 Type 1+2 (Iimp = 1 ka) TNS, TNC 1 1 7 1. 230 2 OVR T1+2 1 2-7 2CTB81101R8900 14134 0.12 1 TT (3 Ph+N), TNS 3+N 1/0 (1) 7/0.1 (1) 1./1. (1) 230 2/2 (1) OVR T1+2 3N 1 2-7 2CTB81101R9000 14141 0.60 1 Type 1+2 (Iimp = 7 ka) 1 7 0 0.9 230 27 OVR T1+2 7 27s P 2CTB81101R3900 13403 0.12 1 2 7 0 0.9/1.4 230 27 OVR T1+2 1N 7 27s P 2CTB81302R1000 1728 0.27 1 4 7 0 0.9/1.4 230 27 OVR T1+2 3N 7 27s P 2CTB8102R1000 173 0. 1 3 7 0 0.9 230 27 OVR T1+2 3L 7 27s P 2CTB81101R4000 13410 0.4 1 4 7 0 0.9 230 27 OVR T1+2 4L 7 27s P 2CTB81101R4100 13427 0. 1-7 0 0.9 230 27 OVR T1+2 7 27s C 2CTB81101R3800 1348 0.1 1-7 0 1.4 230 27 OVR T1+2 70 NC 2CTB81101R100 1742 0.0 1 Type 1 Neutral For TT networks when used in combination with phase Type 1 or Type 1+2 1 2 0.1 < 4-690 OVR T1 2 N 2CTB81101R9700 17043 0.2 1 1 0 0.1 1. - 2 OVR T1 0 N 2CTB81101R0400 1083 0.2 1 1 100 0.1 2-2 OVR T1 100 N 2CTB81101R000 10860 0.2 1 (1) L-N / N-. (3) TS: telesignal contact for remote control of the status of the Surge Protective Device. Bus bar For TT (3Ph+N) networks, this bus bar can be used to connect four single pole Type 1 & Type 1+2 (except for Type 1 with Ifi = 7 ka) - Bus bar 3N 2CTB81102R0400 16091 0.00 0 Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ ABB /9

Selection tables T2 Surge Protective Devices, Type 2 Function: Type 2 are surge arresters. They can handle energy from distant/ indirect lightning strikes or from switching operations. Type 2 can not discharge high energies from direct lightning like Type 1 but they feature lower protection level (Up). They are recommended at the incoming of installation for locations with no exposure to direct lightning impulses. Application: residential, commercial, industrial Standard: IEC 61643-1 / EN 61643-11 8/20 current wave, varistor technology 2CSC400303F0201 2CSC400304F0201 2CSC400302F0201 2CSC400301F0201 2CSC400311F0201 2CSC400311F0201 2CSC400311F0201 Nb. of Maxi. Nominal Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack poles discharge discharge protection voltage operating details 3660308 1 piece group 1 piece unit current current level Un voltage Imax In Up Uc (8/20) (8/20) ka ka kv V V Type code Order code EAN kg ppc. Type 2 (pluggable) TNS, TNC 1 1 1.0 230 27 OVR T2 1 27 P 2CTB80381R2400 12840 0.12 1 1 40 20 1.4 230 27 OVR T2 40 27 P 2CTB80381R2300 12833 0.12 1 1 40 20 1.4 230 27 OVR T2 40 27s P 2CTB80381R2000 12826 0.12 1 1 40 20 1.4 230 27 OVR T2 40 27 P TS 2CTB80381R1700 14363 0.14 1 1 40 20 1.4 230 27 OVR T2 40 27s P TS (3) 2CTB80381R1400 12802 0.1 1 1 70 30 1. 230 27 OVR T2 70 27 s P 2CTB80381R1900 12819 0.12 1 1 70 30 1. 230 27 OVR T2 70 27s P TS (3) 2CTB80381R1300 12796 0.1 1 IT, TNS, TNC 1 1 1. 400 440 OVR T2 1 440 P 2CTB80381R1100 12772 0.12 1 1 40 20 1.9 400 440 OVR T2 40 440 P 2CTB80381R1200 12789 0.12 1 1 40 20 1.9 400 440 OVR T2 40 440 s P 2CTB80381R0800 1276 0.12 1 1 40 20 1.9 400 440 OVR T2 40 440 P TS 2CTB80381R000 14370 0.14 1 1 40 20 1.9 400 440 OVR T2 40 440s P TS (3) 2CTB80381R0200 12741 0.1 1 1 70 30 2 400 440 OVR T2 70 440 s P 2CTB80381R0700 1278 0.12 1 1 70 30 2.0 400 440 OVR T2 70 440s P TS (3) 2CTB80381R0100 12734 0.1 1 1 120 60 2. 400 440 OVR T2 120 440s P TS (3) 2CTB80391R1300 17036 0.12 1 TT, TN-S (1 Ph+N) 1+N 1/70 (1) (1) 1.0/1.4 (1) 230 27/2 (1) OVR T2 1N 1 27 P 2CTB80392R1200 13106 0.22 1 1+N 40/70 (1) 20 (1) 1.4/1.4 (1) 230 27/2 (1) OVR T2 1N 40 27 P 2CTB80392R1100 1320 0.27 1 1+N 40/70 (1) 20 (1) 1.4/1.4 230 27/2 OVR T2 1N 40 27s P 2CTB80392R0800 13090 0.27 1 1+N 40/70 (1) 20 (1) 1.4/1.4 (1) 230 27/2 (1) OVR T2 1N 40 27 P TS 2CTB80392R000 14387 0.27 1 1+N 40/70 (1) 20 (1) 1.4/1.4 (1) 230 27/2 (1) OVR T2 1N 40 27s P TS (3) 2CTB80392R0200 13076 0.27 1 1+N 70/70 (1) 30 (1) 1./1.4 230 27/2 OVR T2 1N 70 27 s P 2CTB80392R0700 13083 0.27 1 1+N 70/70 (1) 30 (1) 1./1.4 (1) 230 27/2 (1) OVR T2 1N 70 27s P TS (3) 2CTB80392R0100 13069 0.27 1 TNC 3 1 (2) (2) 1.0 230 27 OVR T2 3L 1 27 P 2CTB80383R3400 12987 0.3 1 3 40 (2) 20 (2) 1.4 230 27 OVR T2 3L 40 27 P 2CTB80383R2400 13366 0.3 1 3 40 (2) 20 (2) 1.4 230 27 OVR T2 3L 40 27sP 2CTB80383R2200 12963 0.3 1 3 40 (2) 20 (2) 1.4 230 27 OVR T2 3L 40 27 P TS 2CTB80383R200 14400 0.40 1 3 40 (2) 20 (2) 1.4 230 27 OVR T2 3L 40 27s P TS (3) 2CTB80383R2300 12970 0.40 1 3 70 (2) 30 (2) 1. 230 27 OVR T2 3L 70 27 s P 2CTB80383R4100 12994 0.3 1 3 70 (2) 30 (2) 1. 230 27 OVR T2 3L 70 27s P TS (3) 2CTB80383R4400 13007 0.40 1 TNS 4 1 (2) (2) 1.0 230 27 OVR T2 4L 1 27 P 2CTB80383R6000 13038 0.4 1 4 40 (2) 20 (2) 1.4 230 27 OVR T2 4L 40 27 P 2CTB 80383R600 13274 0.4 1 4 40 (2) 20 (2) 1.4 230 27 OVR T2 4L 40 27sP 2CTB80383R400 13021 0.4 1 4 40 (2) 20 (2) 1.4 230 27 OVR T2 4L 40 27 P TS 2CTB80383R200 14417 0.0 1 4 40 (2) 20 (2) 1.4 230 27 OVR T2 4L 40 27s P TS (3) 2CTB80383R000 13014 0.0 1 4 70 (2) 30 (2) 1. 230 27 OVR T2 4L 70 27 s P 2CTB803919R0200 1304 0.4 1 4 70 (2) 30 (2) 1. 230 27 OVR T2 4L 70 27s P TS (3) 2CTB803919R0400 1302 0.0 1 TT, TN-S (3 Ph+N) 3+N 1/70 (1) (1) 1.0/1.4 (1) 230 27/2 (1) OVR T2 3N 1 27 P 2CTB80393R1200 1311 0.4 1 3+N 40/70 (1) 20 (1) 1.4/1.4 (1) 230 27/2 (1) OVR T2 3N 40 27 P 2CTB80393R1100 13267 0.4 1 3+N 40/70 (1) 20 (1) 1.4/1.4 230 27/2 OVR T2 3N 40 27sP 2CTB80393R0800 13144 0.4 1 3+N 40/70 (1) 20 (1) 1.4/1.4 (1) 230 27/2 (1) OVR T2 3N 40 27 P TS 2CTB80393R000 14394 0.0 1 3+N 40/70 (1) 20 (1) 1.4/1.4 (1) 230 27/2 (1) OVR T2 3N 40 27s P TS (3) 2CTB80393R0200 13120 0.0 1 3+N 70/70 (1) 30 (1) 1./1.4 230 27/2 OVR T2 3N 70 27 s P 2CTB80393R0700 13137 0.4 1 3+N 70/70 (1) 30 (1) 1./1.4 (1) 230 27/2 (1) OVR T2 3N 70 27s P TS (3) 2CTB80393R0100 13113 0.0 1 (1) L-N / N-. (2) per pole. (3) TS: telesignal contact for remote control of the status of the Surge Protective Device. The safety reserve(s) ensures a preventive maintenance of the installation. TT*: in TT network for L/N protection only Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ /10 ABB

Selection tables Nb. of Maxi. Nominal Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack T2 poles discharge discharge protection voltage operating details 3660308 1 piece group 1 piece unit current current level Un voltage Imax In Up Uc (8/20) (8/20) ka ka kv V V Type code Order code EAN kg ppc. 2CSC400310F0201 2CSC400307F0201 2CSC400310F0201 2CSC400309F0201 2CSC400309F0201 2CSC400309F0201 2CSC400303F0201 TT (3 Ph+N), TNS 3+N 1 1./1.4 (1) 230 440/2 (1) OVR T2 3N 1-440 P 2CTB80393R1300 366030816800 0.4 1 3+N 40 20 1.9/1.4 (1) 230 440/2 (1) OVR T2 3N 40-440 P 2CTB80393R1400 366030816817 0.4 1 3+N 40 20 1.9/1.4 (1) 230 440/2 (1) OVR T2 3N 40-440 P TS (3) 2CTB80393R100 366030816824 0.4 1 3+N 40 20 1.9/1.4 (1) 230 440/2 (1) OVR T2 3N 40-440s P TS (3) 2CTB80393R1600 366030816831 0.4 1 3+N 70 30 2/1.4 (1) 230 440/2 (1) OVR T2 3N 70-440s P 2CTB80393R1700 366030816848 0.4 1 3+N 70 30 2/1.4 (1) 230 440/2 (1) OVR T2 3N 70-440s P TS (3) 2CTB80393R1800 3660308168 0.4 1 TNC, IT 3 40 20 1.9 230 440 OVR T2 3L 40-440 P 2CTB80383R2600 16879 0.3 1 3 40 20 1.9 230 440 OVR T2 3L 40-440 P TS 2CTB80383R2700 16886 0.40 1 3 70 30 2 230 440 OVR T2 3L 70-440s P 2CTB80383R4200 16893 0.3 1 3 70 30 2 230 440 OVR T2 3L 70-440s P TS 2CTB80383R4300 16909 0.40 1 TNS, IT 4 40 20 1.9/1.4 (1) 230 440 OVR T2 4L 40-440 P 2CTB80383R100 16916 0.4 1 4 40 20 1.9/1.4 (1) 230 440 OVR T2 4L 40-440 P TS 2CTB80383R300 16923 0.0 1 4 70 30 2/1.4 (1) 230 440 OVR T2 4L 70-440s P 2CTB80383R7000 16930 0.4 1 4 70 30 2/1.4 (1) 230 440 OVR T2 4L 70-440s P TS 2CTB80383R7100 16947 0.0 1 Type 2 Neutral 1 70 30 1.4 230 2 OVR T2 70 N P 2CTB80393R1900 16862 OVR Type 2 Special 24/48V AC & DC These type 2 SPD s can be used in very low voltages & data lines for current higher than 140mA. 1 1 0.3 7 7 OVR 1 7 P 2CTB81381R2800 04647 0.12 1 1 1 0.3 7 7 OVR 1 7 P TS 2CTB81381R2700 04630 0.13 1 2 1 0.3/0.6 7 7 OVR 2 1 7 P 2CTB81382R1700 04609 0.22 1 2 1 0.3/0.6 7 7 OVR 2 1 7 P TS 2CTB81382R1600 0493 0.23 1 2 1 0.3/0.6 7 7 OVR 2 1 7s P TS 2CTB81382R1300 0479 0.23 1 Back-up protection by fuse: 16A gg under AC, 16A gr under DC Replacement cartridges for Surge Protective Devices Type 2 Phase cartridge, 7 V - 1 0.3 7 7 OVR 1 7 C 2CTB81384R1400 08892 0.10 1 Phase cartridge, 27 V - 1 1.0 230 27 OVR T2 1 27 C 2CTB80384R1200 13168 0.10 1-40 20 1.4 230 27 OVR T2 40 27 C 2CTB80384R1000 13182 0.10 1-40 20 1.4 230 27 OVR T2 40 27s C (1) 2CTB80384R0900 13199 0.10 1-70 30 1. 230 27 OVR T2 70 27s C (1) 2CTB80384R0700 13229 0.10 1 Neutral cartridge for products OVR T2 1N (..) & OVR T2 3N (..), 27 V - 70 30 1.4-440 OVR T2 70 N C 2CTB80384R0000 13243 0.0 1 Phase cartridge, 440 V - 1 1. 400 440 OVR T2 1 440 C 2CTB80384R0600 1317 0.10 1-40 20 1.9 400 440 OVR T2 40 440 C 2CTB80384R0400 1320 0.10 1-40 20 1.9 400 440 OVR T2 40 440s C (1) 2CTB80384R0300 13212 0.10 1-70 30 2.0 400 440 OVR T2 70 440s C (1) 2CTB80384R0100 13236 0.10 1 T2+T3 3N Nb. of Maxi. Nominal Voltage Voltage Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack poles discharge discharge protection protection combination voltage operating details 3660308 1 piece group 1 piece unit current current level level wave Un voltage Imax In Up Up Uoc Uc (8/20) (8/20) at Uoc ka ka kv kv kv V V Type code Order code EAN kg ppc. Type 3 (non pluggable) 1+N 10 3 0.9/1.4 0.9/1.4 6 230 27 OVR 1N 10 27 2CTB813912R1000 09208 0.2 1 3+N 10 3 0.9/1.4 0.9/1.4 6 230 27 OVR 3N 10 27 2CTB813913R1000 0921 0.4 1 Technical details... pag. 11/131 Overall dimensions... pag. 13/26 Application sheets... pag. 12/ ABB /11

Selection tables T2 3N auto-protected 2CSC400309F0201 Nb. of Maxi. Nominal Voltage Nom. Max. cont. Order Bbn Price Price Weight Pack poles discharge discharge protection voltage operating details 3660308 1 piece group 1 piece unit current current level Un voltage Imax In Up Uc (8/20) (8/20) ka ka kv V V Type code Order code EAN kg ppc. Type 2 (non pluggable) 1 20 1.0 120/240 10 OVR T2 20-10 2CTB804200R0700 1807 0.12 1 1 40 20 1.4 120/240 10 OVR T2 40-10 2CTB804201R0700 18064 0.12 1 1 20 1.0 230/400 27 OVR T2 20-27 2CTB804200R0100 14882 0.12 1 1 40 20 1.4 230/400 27 OVR T2 40-27 2CTB804201R0100 14103 0.12 1 3 20 1.0 230/400 27 OVR T2 3L 20 27 2CTB804600R0400 197 0.3 1 3 40 20 1.4 230/400 27 OVR T2 3L 40-27 2CTB804601R0400 1964 0.3 1 4 20 1.0 230/400 27 OVR T2 4L 20 27 2CTB804600R000 1971 0.4 1 4 40 20 1.4 230/400 27 OVR T2 4L 40-27 2CTB804601R000 1988 0.4 1 N GND TC L 2CSC400309F0201 2CSC400309F0201 2CSC400309F0201 OVR Plus with integrated end of life protection (auto-protected) N+1 40*/40 20/40 1.6/1. 230 320/2 OVR Plus N1 40 2CTB803701R0100 1700 0.26 1 N+3 1/60 /40 1.3/1. 230/400 320 OVR Plus N3 1 2CTB803701R0400 17081 0.79 1 N+3 40/60 20/40 2/1. 230/400 320 OVR Plus N3 40 2CTB803701R0300 17074 0.79 1 *Im = Imax MOV Surge Protective Devices, Low current The transmission line pluggable surge arresters (OVR TC P) provide protection against transient overvoltages for quipment connected to telephone lines (digital or analog), computer links or current loops, for applications such as RS-48, or 4-20 ma. 1 10 0.01 6 OVR TC 6V P 2CTB804820R0000 1230 0.0 1 1 10 0.02 12 OVR TC 12V P 2CTB804820R0100 1247 0.0 1 1 10 0.03 24 OVR TC 24V P 2CTB804820R0200 124 0.0 1 1 10 0.07 48 OVR TC 48V P 2CTB804820R0300 1261 0.0 1 1 10 0.7 200 OVR TC 200V P 2CTB804820R0400 1278 0.0 1 1 10 0.3 200 OVR TC 200FR P 2CTB804820R000 128 0.0 1-10 0.01 7 OVR TC 6V C 2CTB804821R0000 1292 0.02 1-10 0.02 14 OVR TC 12V C 2CTB804821R0100 1308 0.02 1-10 0.03 27 OVR TC 24V C 2CTB804821R0200 131 0.02 1-10 0.07 3 OVR TC 48V C 2CTB804821R0300 1322 0.02 1-10 0.7 220 OVR TC 200V C 2CTB804821R0400 1339 0.02 1-10 0.4 220 OVR TC 200FR C 2CTB804821R000 1346 0.02 1 1 Base OVR TC RJ11 2CTB804840R1000 199 0.02 1 2 Base OVR TC RJ4 2CTB804840R1100 160 0.04 1 Surge Protective Devices, Photovoltaic OVR TC P 200 V in parallel OVR TC P / xx V / 200 FR in series PV 2CSC400309F0201 OVR PV 600 V 2CSC400001F0202 The specific OVR PV range offer a safe and efficient protection against transient overvoltages for equipments on photovoltaic installations. The OVR PV range comply with the UTE C 61-740-1 on surge protective devices connected to photovoltaic generators. Impulse Maxi. Nominal Voltage Max. Short circuit Order Bbn Price Price Weight Pack current discharge discharge protection Cont. DC current details 3660308 1 piece group 1 piece unit current current level Operating withstand Iimp Imax In Up Voltage Iscwpv (10/30) (8/20) (8/20) Ucpv ka ka ka kv V A Type code Order code EAN kg ppc. Type 1 PV, 9 poles 6.2-6.2 1.9 670 100 OVR PV T1 6.2-600 P TS 2CTB80393R700 18361 1.10 1 6.2-6.2 2. 1000 100 OVR PV T1 6.2-1000 P TS 2CTB80393R6700 18378 1.10 1 Type 2 PV. 3 poles - 40 20 1.4 670 100 OVR PV 40-600 P 2CTB80393R300 1610 0.38 1-40 20 1.4 670 100 OVR PV 40-600 P TS 2CTB80393R400 1627 0.39 1-40 20 3.8 1000 100 OVR PV 40-1000 P 2CTB80393R6400 1634 0.38 1-40 20 3.8 1000 100 OVR PV 40-1000 P TS 2CTB80393R600 1641 0.39 1 Replacement cartridges for Surge Protective Devices OVR PV 6.2 - - - 600 - OVR PV T1 6.2-600 C 2CTB80390R1000 18978 0.24 1 6.2 - - - 1000 - OVR PV T1 6.2-1000 C 2CTB80390R1000 18989 0.24 1-40 - - 600 - OVR PV 40-600 C 2CTB80390R0000 168 0.12 1-40 - - 1000 - OVR PV 40-1000 C 2CTB80390R0100 166 0.12 1 - OVR PV MC 2CTB80390R0300 1676 0.12 1 NEW /12 ABB