Variable Speed IPLV.36 kw/tr

Similar documents
Trailblazer AGZ-E air-cooled scroll chillers

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Air Handling Units. With Intelligence

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

Dykin Engineering Part & Services Sdn. Bhd.

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Pathfinder AWV air-cooled screw chillers

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

COMPANY PROFILE OF LESA PROSERV

Efficiency of Data Center cooling

18 th National Award for Excellence in Energy Management. July 27, 2017

MSYS 4480 AC Systems Winter 2015

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

Ecotel Free Cool 5-15kW

Precision Cooling Mission Critical Air Handling Units

MEASURE MONITOR UNDERSTAND

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Performance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Data Center Energy Savings By the numbers

Magnitude magnetic bearing centrifugal chillers

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Energy Engineering: Tools and Trends

Next Generation DCP Optimization using MV VSDs

Samuel Tepp Engineering Seminar Topics

Rack cooling solutions for high density racks management, from 10 to 75 kw

High Efficient Data Center Cooling

Comprehensive Energy Management & Utility Master Plan

DUCTED SPLIT SYSTEMS With Scroll compressors

IT Air Conditioning Units

HOURLY ANALYSIS PROGRAM 5.10

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Beverly D. Grappone Hall Certified LEED Silver Home of NHTI s State-of-the Art Nursing Simulation Center

CARRIER HOURLY ANALYSIS PROGRAM v5.0

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

CASE STUDIES. Brevard Community College: Florida Power & Light. Cape Canaveral Air Force Station: NORESCO

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

ecoenergy Innovation Initiative Research and Development Component Public Report

Driving Proactive Facility Operations with Automated HVAC Diagnostics

ASHRAE elearning Course Catalog

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

New Wisconsin Energy Code: What it Means for Me?

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Introducing the Heat Wheel to the Data Center

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Committed to Energy Efficiency

CLICK TO EDIT MASTER TITLE STYLE. AdvanTEC Solutions CHILLER PLANT HEALTH MANAGER

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Concord Hospital Infrastructure Upgrades Increased Energy and Operating Efficiencies with a Tangible Reduction in Operating Costs

where we are, where we could be, how we can get there. 12/14/2011

Date: 30th August to 1st September 2017 Presented By: Jayant Kad

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

The new generation of dedicated HVAC drives

SE7600E Series Application Guide

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Ecoflair Air Economizers

Indirect Adiabatic and Evaporative Data Center Cooling

Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

The Global HVAC Market. Amber Liu Product Promotion Specialist

Media Pack. ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING

19 th National Award for Excellence in Energy Management ICICI Bank, Chandivli Tower, Mumbai Presenters Atul Parkar Energy Manager Deepak Tyagi Tower

COMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012

Air-Cooled Series R Chiller

Achieving Operational Excellence

What s on the Horizon for HVAC in Title ? Mark Hydeman, PE, Principal Taylor Engineering, LLC

Reliability and extended operation

ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI

Carrier Hong Kong Limited. Carrier Comfort Network. - optimizes the performance of HVAC Systems & is the premier solution for Building Control

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

Self-Contained Air Conditioning Systems

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Commercial HVAC and Other Measures for 7P. Outline

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Energy Efficiency as Competitive Advantage. Houston, TX September 14, 2010

Indirect Adiabatic and Evaporative Data Centre Cooling

We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our

Scalable, Secure. Jason Rylands

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Energy Action Plan 2015

Fle F xs le y xs s y C s on C tr on oller

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

How Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Ceiling Concealed Split System C Series

Data Center Optimized Controls

Transcription:

ACEGWFVXR Series 50 Hz Energy Efficient Variable Speed Water-Cooled Screw Chillers 3 Range from 00 TR to 00 TR Variable Speed IPLV.36 kw/tr GREEN EFFICIENT SUSTAINABLE ACEGWFXR Series 50Hz Energy Efficient Water-Cooled Screw Chillers 3 Range from 00 TR to 350 TR

ACEGADXR R34a 50Hz Energy Efficient Air-Cooled Screw Chillers Range from 00 TR to 380 TR ECBC & GREEN Series Capacity: 00 TR to 380 TR WCFX-V Series 50/60Hz VFD Water Cooled Screw Chillers from Dunham Bush Cooling Capacity: 33 to 665 TR (467 to 340 kw) Variable Speed IPLV.36 kw/tr 3

DCLC Series 50Hz Water Cooled Centrifugal Chillers from Dunham Bush Cooling Capacity: 300 to 500 TR (055 to 574 kw) WCFX-E Series 50Hz Water Cooled Rotary Screw Chillers from Dunham Bush Cooling Capacity: 60 to 843 TR ( to 965 kw) 3 Multiple Compressor Configuration from 00 TR and above 4

AFVX Series (High Ambient) 50Hz Air Cooled Screw Flooded Chillers from Dunham Bush Cooling Capacity: 85 to 445 TR (99 to 565 kw) AFVXB Series 50Hz Air Cooled Screw Flooded Chillers from Dunham Bush Cooling Capacity: 00 to 50 TR (35 to 830 kw) 5

Voltas Absorption Chillers Direct Fired & CO-GEN Model Capacity Range from: 0 TR to 450 TR Heat Source: HSD / LDO / SKO / Natural Gas The New Generation Machines with Advanced Paraflow Technology Featuring High Reliability & Efficiency manufactured & Tested state-of the-art facilities in India, to the highest standards. Small Direct Fired (Koala Series) Capacity Range from: 40 TR to 00 TR Heat Source: HSD / LDO / SKO / Natural Gas Voltas Absorption Chillers Hot Water Model Capacity Range from: 60 TR to 000 TR Heat Source: Saturated Steam at.0kg/cmg, Low Temp. At 85 Hot Water, High Temp. At 40 Hot Water The New Generation Machines with Advanced Paraflow Technology Featuring High Reliability & Efficiency manufactured & Tested state-of the-art facilities in India, to the highest standards. Double Effects & Steam Fired Capacity Range from: 40 TR to 450 TR Heat Source: Saturated Steam 8kg/cmg 6

Outdoor Units Up to 80 HP The Next Generation VOLTAS VRF System Variable Refrigerant Flow System with DC Inverter Scroll Compressors Features DC fan motor, low noise, low power consumption 80 sine-wave DC inverter control Full Inverter: all DC inverter compressors Modular : DC inverter + AC fixed compressor 7

Wide Range of Indoor Units Microprocessor-Controlled Packaged & Ductable Split Units Capacity Range 6 TR to 4 TR 8

INTELLISYS Range with R40A Capacity Range: 6 TR to 8 TR Outdoor Units - Up to 80 HP A comfortable future begins with sustainable cooling solutions. Voltas is committed to providing innovative HVAC solutions that benefit our customers as well as the environment. Our proactive development of R40A refrigerant systems are designed to be the INTELLIGENT and COMPACT, to cater to your total sustainable cooling requirements. Air Quality & Energy Management Systems Engineered Ozone Systems Supervisory Ozone Monitor CZ Controzone CZ8 LAN Controzone CZ6 Sc &CZ6 C Supervisory Ozone Monitor CZ 9

Air Quality & Energy Management Systems First Engineered OZONE System in the World Qualifying to UL 867A Silent Feature of IAQ Management system Reduction to near total elimination of VOC and odor Sustains CO below,000 PPM No replacement consumable is required Power to operate is very low Eliminates mold and fungi in AC ducts Operates with outdoor air less than 5 Cfm / Person while yet delivering the IAQ benefits. System in total conformity with ASHRAE Demand Load Ventilation Operation fully automatic with microprocessor based monitors and controllers. All IAQ parameters displayed remotely through web based IP. Supports monitoring and continuous audit of IAQ and energy parameters. Issues automatic alerts on email if IAQ or energy parameters are not within optimum range. Reduces energy consumed by AC plant up to 0 % Reduces water consumed by AC plant up to 0 % Results in Cap Ex savings of AC system ROI is typically to 3 years The entire system is UL listed for operational safety (UL 995), safety against fire and smoke (UL 043), and for safety for use in human occupied space (UL 867A). COILOTRON Perfect System for Mold Free Cooling Coil and Drain Pan Fire and Smoke Test to UL 043 Near Total Elimination of Mold, Fungi, and Microbes on Cooling Coil and Drain Pan Clean and new looking Cooling Coil Near 00 % elimination of Endotoxin and Pathogens on coil Reduces allergy symptoms, SBS, and indoor air related sickness Improves Heat Transfer Efficiency up to 0 % Results in reduced energy Earns LEED and GBC Merit Points Environmentally Friendly Suitable for new or retrofit installations Easy to Install Quick Return on Investment 0

GERMITRON Suitable for Hospitals, Speciality Labs, Animal Houses etc Indoor Air Quality & Bactericidal Management System Achieves 90% Kill Rate of Bacteria and Virus, per pass Scientifically Proven Design with Computerized Selection to assure delivery of Specified or Target Kill Rate. Custom Designed to suit airflow and duct size Rated Average Life of Lamps is 6,000 Hours, longest in the Industry High Energy output 800 ma Lamps Lamps installed in frame mounted Quartz Sleeve Easy and quick Lamp change, without withdrawal or removal of frame from duct work or access door, or Quartz Sleeve Indicating lamp to show Lamp failure, without opening access door, or turning off power Fire and Smoke Test to UL 043 Integrated Approach from Design To Commissioning Design Management Project Management Construction Management Risk Management Testing Balancing Commissioning Customer Care

Indira Paryavaran Bhawan - First Net Zero Building Of INDIA Project Highlights This is the First NET ZERO building of India with LEED Platinum certification and GRIHA Five Star certification for Exemplary Demonstration of Renewable Technologies. India s First Net Zero Building. First time used of Condensing Chilled Beam Unit with Drain Pan suitable for Hot & Humid climate like India. Total Energy savings of about 40% has been achieved by adoption of Energy Efficient Chilled Beam Unit. Reduction in Water Consumption has been achieved by use of GEO- Thermal System. Energy efficient VFD Driven Screw Chillers of IPLV.37 kw / TR Energy Produced per year 4,9,000 kwh & Energy Consumption for building per year 4,,000 kwh

First Time Use of Condensing Chilled Beams Suitable for Hot and Humid Climate like India. BRIEF DETAIL OF IGPB - Equipment Details Screw Chillers: 40 nos ( one standby), 00 TR nos along with Variable pumping system and cooling towers( only for conventional system) Air handling units 3 numbers for chilled beams, 9 nos for conventional system ( for Meeting / common areas) Heat recovery units : 0 nos Chilled Beams: 376 numbers. Geo thermal System : for heat rejection of 80 TR Ventilation fans : 6 for smoke extraction, 4 for normal ventilation VAV boxes : 4 numbers BMS system: way PIVC valves along with motorized butterfly valves. Air cooled DX type packaged units: 03 numbers BRIEF DETAIL OF IGPB - Details of HVAC System Total Air Conditioned Area 0000 sqft Area air conditioned with chilled beams 93000 sqft 30 TR (00 by chilled beams,0 Tr by primary air AHUs) Area air conditioned with conventional system 7000 sqft 30 TR (load) Ventilation Area 06400 sqft (Three basements) 3

Blueridge IT Park, Pune Project Highlights LEED Gold Standard Green Building IT SEZ Park, Pune Total Air conditioning Area million sqft Total Air conditioning capacity 5,000 TR Energy saving through IAQ Management & Demand Load Ventilation 700 TR Project Completion Date May 0 (Phase ) 4

Some of our state-of-the-art MEP projects Netaji Subhash Chandra Bose International Airport, Kolkata HVAC, Electrical works, Plumbing, Water treatment Delhi / Chnnai Metro Rail Project Underground stations: Airconditioning Automatice control & Monitoring system, Electrical Power supply & distribution system Buddh International Circuit, Greater Noida Seasons Mall, Magarpatta HVAC & Fire Fighting Cybercity, Magarpatta HVAC The 5 Star Sofitel Hotel, Mumbai HVAC, Electrical, Plumbing, Fire fighting Responsible, Reliable & Efficient Customer Care: 800 33 0 800 66 000 5

Thank you 6