Specifications. S&C Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv and 27 kv)

Similar documents
Specifications. S&C IntelliNode Interface Modules. Conditions of Sale

Specifications. S&C IntelliNode Interface Modules

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

S&C IntelliRupter PulseCloser Fault Interrupter

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Specifications. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) For Remote Supervisory Control

S&C 6801M Automatic Switch Operator

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Specif ications. S&C Remote Supervisory Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv)

Specifications. S&C 6802 and 6803 Automatic Switch Controls

Specifications. S&C Scada-Mate CX Switching System Outdoor Distribution (14.4 kv and 25 kv)

Primary Injection Test Procedure

Docking Station Instructions

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

Source-Transfer Application Guide

Specifications. S&C 6801 Automatic Switch Controls

Product Description. S&C 5800 Series Automatic Switch Control S&C ELECTRIC COMPANY TABLE OF CONTENTS

Specifications. S&C Micro-AT Source-Transfer Control. In Weatherproof Enclosure

S&C IntelliRupter PulseCloser. Outdoor Distribution 14.4 kv and 25 kv

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

Wi-Fi and Security Administration

DNP Points List and Implementation

IntelliTeam II Automatic Restoration System

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Specifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.

Operating and Diagnostic Instructions for IntelliTeam SG Automatic Restoration System

DNP Points List and Implementation

Specif ications. S&C Alduti-Rupter Switches Outdoor Distribution (14.4 kv through 69 kv)

Elastimold Molded Vacuum Recloser - MVR

DNP Points List and Implementation for Universal Controls

Installation. Section Page Section Page NOTICE

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Specifications. S&C Loadbuster Disconnect Switches Outdoor Distribution (14.4 kv through 34.5 kv)

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Operation. S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Table of Contents

Table of Contents Section Page Section Page Introduction Safety Information Installation Diagrams Installation

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

S&C Scada-Mate Switching Systems Outdoor Distribution (14.4 kv through 34.5 kv)

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

IPR-150 INSTALLATION GUIDE 150KVA Three-Phase Release 1.0

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

Specifications. S&C Loadbuster Disconnects a Outdoor Distribution (14.4 kv through 34.5 kv)

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

NU-LEC. Loop Automation. Reclosers & Sectionalizers

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Mr. Russell James Irby Utilities 7125 Belton Street Fort Worth, TX 76118

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

SPECIAL SPECIFICATION 1303 Lifelink

SPECIAL SPECIFICATION 1826 Field Ethernet Switch

Vista SD Portable Remote Control Pendant

ASCO 920 Remote Control (RC) Switches

Setup. S&C 5800 Series Automatic Switch Controls With IntelliTeam Automatic Restoration System. Table of Contents. Instruction Sheet

920 Remote Control (RC) Switches

SECTION SWITCHBOARDS

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

PG&E Points List for Universal Controls

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

DNP Points List and Implementation for the 6802 Vista Control

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION ( ) LIGHTING CONTROL PANELBOARD

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

PS/IO Circuit Board Retrofit

Meter Enclosure and Equipment Standards

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

SERIES SD3800 / SD3810 SPECIFICATION

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

Products Portfolio. Pole mounted Vacuum Recloser

SECTION DISCONNECT SWITCHES

Specification Voltage Limiting Device

1510 MOTOR CONTROLLERS

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List

Model HM-535 Power Supply Installation and Service Instructions

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

SPECIAL SPECIFICATION 8371 Field Terminal Server

Bus Bar Protection Relay B-PRO 4000

ELG4125: System Protection

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

1. Coordination of series-rated devices is permitted where indicated on Drawings.

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

SPECIAL SPECIFICATION 8143 Wireless Ethernet Radio System

Setup Instructions. S&C Universal Interface Module. Table of Contents. Instruction Sheet

Document C0. Use for:

SPECIAL SPECIFICATION 8885 Wireless Ethernet Radio (Backhaul) Link

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Siemens Fusesaver and Remote Control Unit 3AD8

Transcription:

Outdoor Distribution (155 kv and 27 kv) Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheets 150 and 181 apply, except as modified by the SPECIAL WARRANTY PROVISIONS and WARRANTY QUALIFICATIONS on pages 6 and 7 SPECIAL TO THIS PRODUCT AND ASSOCIATED SERVICES: NOTE: S&C Pad-Mounted Style IntelliRupter fault interrupters accommodate separable insulated connectors and accessories This equipment must be operated by qualified persons who are thoroughly trained in, and who understand any hazards that may be involved with, the operation of separable insulated connectors and related accessories INCLUSIONS: A Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter is a unitized package of fault-interrupting and control components that provides fault-isolation and circuit-restoration functions on an underground distribution system IntelliRupter fault interrupters can operate as stand-alone fault interrupters or, with appropriate options, can be integrated into a SCADA system and/or an S&C IntelliTeam SG Automatic Restoration System IntelliRupter fault interrupters feature PulseClosing Technology a unique test for verifying the line is clear of faults before initiating a close operation PulseClosing Technology is superior to conventional reclosing It greatly reduces stress on system components as well as voltage sags experienced by customers upstream of the fault IntelliRupter fault interrupters provide full live-switching performance under all conditions The circuit-making, circuit-breaking, and use of PulseClosing Technology are accomplished within the interrupters; there are no external moving parts Each IntelliRupter fault interrupter is factory-assembled in a freestanding, self-supporting enclosure with provisions for cable entrance and exit through the bottom The enclosure meets the requirements of ANSI C571228 (enclosure integrity) Pad-Mounted Style IntelliRupter fault interrupters have these features: Three-pole vacuum interrupters rated 630 amperes continuous, 16,000 amperes interrupting at 155 kv, and 12,500 amperes interrupting at 27 kv Unique magnetic latching actuators that provide singlephase tripping/single-phase lockout, single-phase tripping/three-phase lockout, or three-phase tripping/ three-phase lockout of the interrupters (IntelliRupter fault interrupters can also be manually tripped by a manual OPEN/CLOSE/READY lever) Sensors for three-phase monitoring of line current and three-phase monitoring of line voltage on both sides of the interrupters Choice of one integral power module, which derives necessary control power directly from the distribution feeder or an external power supply for use when user-provided control power is available (Other control power source options are available See Table 3 on page 9; one control power source must be specified) An OPEN/CLOSED indicator for each phase An external power supply connector (This permits preinstallation uploading and downloading of configuration settings, plus radio programming and battery charging, as applicable, indoors in the user s service center or lab) A manually actuated OPEN/CLOSE/READY lever A manually actuated GROUND TRIP BLOCK toggle switch A manually actuated HOT-LINE TAG toggle switch to enable or disable a hot line-tag or disable an electronically set hot-line tag A control group featuring a protection and control module and a communication module mounted in a low-voltage compartment (The IntelliRupter fault interrupter is easily configured and operated from the safety and security of a vehicle parked near the Pad-Mounted Style IntelliRupter fault interrupter by means of a secure Wi-Fi communication link to a laptop computer The protection and control module and communication module can be easily removed from service using the included module stub handle, catalog number 4435) A unique multifunction status light that shows the control group operation (The blink rate changes if a Wi-Fi connection is made, control power is lost, or the position of the OPEN/CLOSE/READY lever has been changed A separate Hot-Line Tag indicator shows a set tag) An integrated Global Positioning System (The system provides 1-ms accurate time-stamping of events to speed post-event analysis as well as IntelliRupter fault interrupter location data for entry in the user s graphical information system) Access to compartments controlled by the S&C Penta-Latch Mechanism, which provides automatic door latching and permits padlocking only when the door is securely latched (The doors can be opened only with a pentahead socket wrench or tool) September 10, 2018 S&C Electric Company 2012-2018, all rights reserved Specification Bulletin 766A-31

Conditions of Sale Continued An enclosure roof undercoated with an insulating no-drip compound (A resilient closed-cell gasket on the enclosure bottom flange protects the finish from being scratched during installation and isolates it from the alkalinity of a concrete foundation The enclosure is protected from corrosion by S&C s olive green Ultradur Finishing System) Terminals equipped with 600-ampere bushings, with studs (The bushing interfaces are in accordance with ANSI/IEEE Standard 386 to accept all standard separable insulated connectors Parking stands are provided adjacent to each bushing Grounding provisions suitable for use with separable insulated connectors and related accessories are located in the termination compartment) A hinged roof section over the cable-termination compartment Application Note: The cable-termination compartment can accommodate either single 600-ampere deadbreak connectors equipped with elbow-style surge arresters or stacked (two) 600-ampere deadbreak connectors without elbow-style surge arresters See Application Notes on page 6 concerning the need for surge arresters on both sides of the IntelliRupter fault interrupter Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters are available with or without an integral disconnect for visible air-gap isolation of switched-open circuits A status point for remote monitoring of the disconnect position is included Interrupters may be operated with the disconnect in either position IntelliRupter fault interrupter pole-units are molded of S&C Cypoxy Insulator insulation The sensors are embedded, eliminating the cost, clutter, and complexity associated with separately mounted sensors Sensing accuracy is ±05% for both voltage and current; total system accuracy for fault detection, including sensing, control, and interrupting time, is ±2% IntelliRupter fault interrupters include on-site user training on setup, configuration, and operation These services apply to first-time orders only; they can be provided for subsequent orders at the charge indicated in Table 13 on page 15 Control Groups Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters are available with a variety of control groups Each features easy configuration and operation and examination of waveforms and events using secure wireless communication to a nearby laptop computer The protection and control module and the communication module are easily removed from the base with a module-handling fitting attached to a hookstick This flexible, low-maintenance arrangement offers excellent immunity to surges and noise induced by normal power-line events such as faults and lightning strikes IntelliRupter fault interrupters are powered from the distribution feeder through the integral power module(s) or the external power supply, if furnished The protection and control module provides point-onwave closing to minimize asymmetric fault current and inrush current It features a complete set of protection and control functions, including: Simultaneous independent directional-phase, ground, negative-sequence, and sensitive-earth time-overcurrent, instantaneous-overcurrent, and definite-time elements Directional blocking of overcurrent elements Over/under voltage elements Over/under frequency elements Phase-unbalance detection Synchronization check A cold-load pickup modifier User-selectable single-phase or three-phase tripping at any point in the test sequence with single-phase or three-phase lockout Comprehensive diagnostics, including data and waveform capture The protection group is automatically selected in response to the system configuration for optimized protection The protection and control module provides sophisticated remote terminal unit (RTU) functionality, including remote reporting of IntelliRupter fault interrupter status points and operations, as well as current, voltage, watts, and vars A 20-channel global-positioning system (GPS) receiver in the communication module provides 1-ms accurate time-stamping of events to speed post-event analysis as well as IntelliRupter fault interrupter location data to help maintain the user s graphical information system Select the control group that meets the requirements of the distribution system Standard Control Group The Standard Control Group is suitable for the following applications: The IntelliTeam SG Automatic Restoration System (Teams use peer-to-peer communication, real-time data, and distributed intelligence to make automatic operating decisions No central processing or SCADA is required, though they are fully supported Each IntelliRupter fault interrupter must be furnished with an S&C SpeedNet Radio or other approved communication device) 2 S&C Specification Bulletin 766A-31

Automatic source transfer using two IntelliRupter fault interrupters (The IntelliRupter fault interrupters ensure a high degree of critical-load continuity by minimizing interruptions resulting from the loss of one source Each IntelliRupter fault interrupter must be furnished with an S&C SpeedNet Radio or other approved communication device) Automatic loop restoration using normally closed IntelliRupter fault interrupters or conventional reclosers with a normally open IntelliRupter fault interrupter switching point (The feeder on either side of the switching point can be fed from a different source If a fault occurs on either feeder, the normally closed devices in that feeder open and then test the circuit using PulseClosing Technology (or reclosing) sequentially to sectionalize and isolate the fault Service is automatically restored to unfaulted line segments by closing the normally open IntelliRupter fault interrupter) Wide-area SCADA, when equipped with an S&C SpeedNet Radio or other approved communication device Standalone (noncommunicating) applications Approved communication devices permit configuration, operation, interrogation, and software maintenance of IntelliRupter fault interrupters from any location having access to the communication system using optional IntelliLink Remote Setup Software No batteries are required for standalone applications and applications with operating times of 30 seconds or less; ac line voltage must be available on the side of the IntelliRupter fault interrupter with the integral power module, or control power must be available from the external power supply, if furnished The Standard Control Group includes IntelliTeam SG Bronze Level Software When furnished with optional IntelliTeam SG Silver Level Software, the Standard Control Group is additionally suitable for basic closed-loop applications When furnished with optional IntelliTeam SG Gold Level Software, the Standard Control Group is additionally suitable for basic closed-loop applications and applications on systems with three or more sources IntelliTeam Designer configuration and licensemanagement software is required to activate IntelliTeam SG software Standard Control Group with Battery Backup This control group is identical to the Standard Control Group and is suitable for the same applications It additionally includes batteries that support operation for a minimum of four hours after loss of ac line voltage on both sides of the IntelliRupter fault interrupter, permitting extended dead-line switching Group with Battery Backup but includes either IntelliTeam SG Gold Level Software and IntelliTeam Designer configuration and license-management software or an IntelliTeam II Automatic Restoration System software license, as specified When the former is specified, the Universal Control Group is suitable for all applications of the Standard Control Group with Battery Backup as well as basic closed-loop applications and applications on systems with three or more sources When the latter is specified, the Universal Control Group is suitable for all IntelliTeam II applications Equipment/Services Packages Complete equipment/services packages are available for three- through 12-member IntelliRupter fault interrupter teams, as listed in Table 13 on page 15 Each team member includes the IntelliTeam SG Automatic Restoration System and a SpeedNet Radio One SpeedNet Repeater Radio is also included with the team Each package includes the following services: A communication site survey IntelliTeam SG system factory acceptance testing IntelliTeam SG system training IntelliTeam SG system commissioning IntelliRupter fault interrupter training Services-Only Packages Services-only packages are also available for Pad- Mounted Style IntelliRupter PulseCloser Fault Interrupters as listed in Table 14 on page 15 Offerings include: Communication site surveys Overcurrent protective device-coordination studies IntelliTeam SG system device settings determination IntelliTeam SG system factory acceptance testing IntelliTeam SG system training IntelliTeam SG system commissioning IntelliTeam SG system SCADA integration IntelliTeam SG system monitoring Loop-restoration training IntelliRupter fault interrupter training IntelliRupter fault interrupter maintenance IntelliRupter fault interrupter project and construction management Universal Control Group This control group is identical to the Standard Control S&C Specification Bulletin 766A-31 3

Communication Site Surveys A communication site survey is required for new IntelliTeam SG system applications and is critical to ensure acceptable signal strength between the IntelliRupter fault interrupters in the team and the head-end SCADA radio, if applicable A site survey includes: An engineering review of selected team member sites that considers distance, topological constraints, and other factors that can affect signal strength An on-site survey of team member sites to confirm feasibility and, if necessary, determination of alternative sites that will provide better signal strength A detailed report defining the GPS coordinates of all team and repeater radios Establishment of baseline communication statistics for monitoring communication system performance Training on installation and configuration of SpeedNet Radios or UtiliNet Radios The user will need to supply a line truck and the engineer/technician responsible for the project The site survey ensures optimal communication when the system is commissioned However, building construction, relocation of lines, vegetation growth, and other factors can degrade communication over time A subsequent tune-up site survey may be desirable Overcurrent Protective Device Coordination Studies A coordination study is used to select appropriately rated protective devices and their settings, including those of IntelliRupter fault interrupters Proper protective device coordination minimizes the impact of short-circuits by isolating faults as quickly as possible while maintaining power to the rest of the system IntelliTeam SG System Device Settings Determination Appropriate device settings are essential to the successful implementation of the IntelliTeam SG Automatic Restoration System These settings must be documented before factory acceptance testing and commissioning of the IntelliTeam SG Automatic Restoration System IntelliTeam SG System Factory Acceptance Testing Factory acceptance testing ensures all information required for a successful IntelliTeam SG implementation is gathered and understood before commissioning and is strongly recommended if there are any unusual system characteristics or loading limitations It provides significant insight into how the IntelliTeam SG Automatic Restoration System will work on the user s system the specific system-protection settings, available fault currents, connected loads, etc To perform this testing, the user must furnish the following: Substation breaker data, including overcurrent pickup levels and relay timer settings Available fault current at each IntelliRupter fault interrupter location or if S&C is providing an overcurrent protective device coordination study and/or determination of IntelliTeam SG device settings information that will allow S&C to calculate these values Any substation-capacity, conductor-loading, or systemoperating-rule limitations A written description of the desired system functionality A single-line diagram of the circuits on which the IntelliTeam SG Automatic Restoration System will be applied Completed IntelliTeam SG settings sheets (Determination of device settings is the customer s responsibility, or it can be provided by S&C) Factory acceptance testing is performed at S&C s IntelliLab facility in Chicago S&C will provide a detailed test plan After testing has been completed, the user will receive a CD-ROM containing the results of each simulation, which the user can use for training IntelliTeam SG System Training IntelliTeam SG system training is conducted on-site and ensures the user s personnel fully understand IntelliTeam SG functioning Both operations and engineering sessions are provided Operations training is geared toward persons who will encounter the equipment in the field, dispatch personnel, or create switching orders A typical agenda includes: An IntelliTeam SG Automatic Restoration System what it is, how it works, and examples Operation of IntelliRupter fault interrupters in an IntelliTeam SG system Real-world examples of IntelliTeam SG system operation using IntelliTeam Designer in Instant Replay mode Engineering training geared toward engineers and technicians who will configure the controls and radios A typical agenda includes: A detailed look at how the IntelliTeam SG Automatic Restoration System works Explanation of all control settings Software screens useful for troubleshooting Configuration of the radios Creation of a DNP lookup table IntelliTeam SG System Commissioning IntelliTeam SG system commissioning ensures the IntelliRupter fault interrupters in the team have been set up correctly and are ready to be put into service These services include: 4 S&C Specification Bulletin 766A-31

Assistance with configuring the IntelliRupter fault interrupters (Determination of device settings is the customer s responsibility, or it can be provided by S&C) Verification of acceptable peer-to-peer communication Verification of acceptable communication with the SCADA system Checking each IntelliRupter fault interrupter for conformance with installation recommendations Verification that each team is capable of achieving Ready status (Upon user request, the teams will be disabled after verification) IntelliTeam SG System SCADA Integration If the IntelliTeam SG Automatic Restoration System is to communicate with a SCADA system, integration services may be desirable These services include: Working with the SCADA supplier Designing and installing the communication infrastructure linking the IntelliTeam SG Automatic Restoration System with the user s LAN Developing the protocol conversion necessary to change DNP into the native language of the SCADA master Developing optimal SCADA settings and polling sequence IntelliTeam SG System Monitoring Ongoing remote system monitoring ensures IntelliTeam SG system operation meets agreed-upon service levels It requires a SpeedGate Radio Interface with a wireless telephone modem If wireless telephone service is not available, a telephone modem and a user-supplied telephone line must be installed at the SpeedGate Radio Interface System monitoring allows S&C s engineers to assist with any required troubleshooting, update configurations, and provide weekly health reports on the status of the system Such reports can include: Team Ready status IntelliTeam SG system operational status Battery system status Active trouble conditions or alarms The scope and format of the reports can be customized to meet specific user needs IntelliRupter Fault Interrupter Training This training is conducted on-site and ensures the user s personnel know how to properly set up, configure, and operate IntelliRupter fault interrupters These services include: Training on use of IntelliLink Setup Software Configuring IntelliRupter fault interrupters for use in a loop-restoration system, if applicable Use of security keys IntelliRupter fault interrupter operation, including PulseClosing Technology These services are provided for first-time orders IntelliRupter Fault Interrupter Maintenance IntelliRupter fault interrupter maintenance includes periodic field inspection and testing on a three-year interval Services provided for each team member include: Visual inspection of the IntelliRupter fault interrupter, antenna, grounding, and wiring connections Verification of IntelliLink Setup Software operation through a secure Wi-Fi connection Downloading of a full report from the IntelliRupter fault interrupter, review of the data, and execution of any corrective actions necessary Replacement of the battery Operation of the IntelliRupter fault interrupter (if it can be bypassed) locally, manually, and from SCADA Inspection of the repeater radio and replacement of its battery Communication-statistics monitoring and comparison against the initial baseline Identification of recommended communication enhancements All system maintenance is coordinated with the user s designee To facilitate the inspection process and ensure consistent and accurate reporting, S&C will work with the designee to develop an inspection checklist and train inspection crews on its importance and use Loop-Restoration Training This training is conducted on-site and ensures the user s personnel know how to properly set up, configure, and operate IntelliRupter fault interrupters in a loop application comprised of normally closed IntelliRupter fault interrupters or conventional reclosers with a normally open IntelliRupter fault interrupter switching point S&C Specification Bulletin 766A-31 5

IntelliRupter Fault Interrupter Project and Construction Management S&C s highly trained and experienced staff will assist the user s automation team in the areas of project and construction management and work closely with them to ensure on-time project completion Services may include working with the user s contractor or crew to: Ensure proper installation of the IntelliRupter fault interrupters Supply the automation system as a complete turnkey or Engineer-Procure-Construct (EPC) project EXCLUSIONS: Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters do not include separable insulated connectors A connector suitable for grounding the enclosure is listed in Table 10 on page 13 Equipment/ services packages and services-only packages do not include field installation or construction labor IntelliRupter fault interrupters furnished with Standard Control Group or Standard Control Group with Battery Backup do not include optional IntelliTeam SG Silver Level Software, IntelliTeam SG Gold Level Software, or IntelliTeam Designer Configuration and License Management Software For non-intelliteam SG applications, S&C may be able to furnish and install in the communication module or make provision for a customer-specified communication device not listed in Table 8 on page 12 S&C will need to evaluate the physical and electrical requirements of the communication device and its performance characteristics and conduct qualification testing to verify its suitability for the desired application Refer to the nearest S&C Sales Office for scheduling information S&C cannot furnish or install any communication device for which the supplier requires S&C to offer Tier I (ie, help desk ) support If a licensed radio is required for a SCADA interface, the frequency selection and FCC license application are to be provided by others S&C can provide a radio propagation study as well as a general system review to ensure optimal application of distribution automation components APPLICATION NOTES: The following factors should be considered when applying Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters: System voltage restrictions For adequate power to be available from the integral power module(s), an IntelliRupter fault interrupter must be applied on a system that is solidly grounded, uni-grounded, grounded through a grounding transformer, or resonant-grounded through a Peterson coil The base of the IntelliRupter fault interrupter must be grounded, and the line-to-line voltage must be in the range shown in the following table: Range, kv, at 60 Hz Range, kv, at 50 Hz 1143 through 155 90 through 192 1881 through 27 20 through 24 When furnished with the external power supply, an IntelliRupter fault interrupter may be applied at line-toline voltage as low as 413 kv, 50/60 Hz For application on a completely ungrounded system, the external power supply must be specified, less integral power module(s) Integral power modules cannot be applied on completely ungrounded systems Application of surge arresters Elbow-style surge arresters are required on both sides of an IntelliRupter fault interrupter when installed on feeders to protect it from surges beyond its ratings When installed in substations or at the base of riser/dip poles, surge arresters are only required on the load side of IntelliRupter fault interrupter SPECIAL WARRANTY PROVISIONS: The standard warranty contained in the seller s standard conditions of sale, as set forth in Price Sheets 150 and 181, applies to the Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupter and its associated options, except for the control group, as applicable For these devices, the first and second paragraphs of said warranty are replaced by the following: (1) General: The seller warrants to the immediate purchaser or end user for a period of 10 years from the date of shipment that the equipment delivered, with the exception of S&C SpeedNet Radio, will be of the kind and quality specified in the contract description and will be free of defects of workmanship and material S&C's SpeedNet Radio is similarly warranted for a period of two years from the date of shipment Should any failure to conform to this warranty appear under proper and normal use within 10 years after the date of shipment (two years for S&C SpeedNet Radios) the seller agrees, upon prompt notification thereof and confirmation that the equipment has been stored, installed, operated, and maintained in accordance with recommendations of the seller and standard industry practice, to correct the nonconformity either by repairing any damaged or defective parts of the equipment, or (at the seller s option) by shipment of necessary replacement parts The seller s warranty does not apply to any equipment that has been disassembled, repaired, or altered by anyone other than the seller This limited warranty is granted only to the immediate purchaser or, if the equipment is purchased by a third party for installation in third-party equipment, the end user of the equipment The seller s 6 S&C Specification Bulletin 766A-31

duty to perform under any warranty may be delayed, at the seller s sole option, until the seller has been paid in full for all goods purchased by the immediate purchaser No such delay shall extend the warranty period The seller further warrants to the immediate purchaser or end user that for a period of two years from the date of shipment, the software will perform substantially in accordance with the then-current release of specifications if properly used in accordance with the procedures described in seller s instructions The seller s liability regarding any of the software is expressly limited to exercising its reasonable efforts in supplying or replacing any media found to be physically defective or in correcting defects in the software during the warranty period The seller does not warrant the use of the software will be uninterrupted or error-free For equipment/services packages, the seller warrants, for a period of one year after commissioning, that the IntelliRupter fault interrupters will provide automatic fault isolation and system reconfiguration per agreed-upon service levels The remedy shall be additional system analysis and reconfiguration of the IntelliTeam SG Automatic Restoration System until the desired result is achieved WARRANTY QUALIFICATIONS: The standard warranty contained in the seller s standard conditions of sale, as set forth in Price Sheets 150 and 181, does not apply to major components not of S&C manufacture, such as batteries, customer-specified remote terminal units, and communication devices, as well as hardware, software, resolution of protocol-related matters, and notification of upgrades or fixes for those devices The seller will assign to the immediate purchaser or end user all manufacturers warranties that apply to such major components The seller s standard warranty does not apply to any components not of S&C manufacture that are supplied and installed by the purchaser or to the ability of the seller s equipment to work with such components Warranty of equipment/services packages is contingent upon receipt of adequate information on the user s distribution system, sufficiently detailed to prepare a technical analysis The seller is not liable if an act of nature or parties beyond S&C s control negatively impact performance of equipment/services packages; for example, new construction that impedes radio communication or changes to the distribution system that affect protection systems, available fault currents, or system loading characteristics END USER LICENSE AGREEMENT: The end user is granted a nontransferable, non-sublicensable, nonexclusive license to use the LinkStart Connection Management Software, IntelliLink Remote Setup Software, IntelliTeam Automatic Restoration Software, Loop Restoration Software, and/or other software furnished with the IntelliRupter PulseCloser Fault Interrupter only upon acceptance of all the terms and conditions of the seller s end user license agreement set forth in Price Sheet 155 How to Order 1 Obtain the catalog number of the desired Pad-Mounted Style IntelliRupter fault interrupter from Tables 1 and 2 on page 8 2 Add the suffix of the desired control power source option from Table 3 on page 9 3 Add the suffix of the desired control group option from Table 5 on page 10 4 Add the suffix(s) of desired optional features and special optional features from Tables 6 and 7 on page 11 5 If wide-area network capability is desired for the Standard Control Group, Standard Control Group with Battery Backup, or Universal Control Group, add the suffix of the desired communication device from Table 8 on page 12 6 Obtain the catalog number of the desired connector from Table 10 on page 13 7 Obtain the catalog numbers of desired accessories and touch-up kit components from Tables 9, 11, and 12 on pages 13 through 15 S&C Specification Bulletin 766A-31 7

Table 1 Non-Disconnect Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters12 Ratings Circuit Diagram kv Max BIL Cont Amperes, RMS Interrupting Symmetrical Catalog Number3 COMPARTMENT-2 Y3 X3 Y2 X2 Y1 X1 COMPARTMENT-1 L V C 155 27 95 125 630 630 16 0004 12 5005 248812R1 248813R1 1 For adequate power to be available from the integral power module(s), the base of the IntelliRupter fault interrupter must be grounded 2 When applied on a system that is not solidly grounded, uni-grounded, grounded through a grounding transformer, or resonant-grounded through a Peterson coil, total system phase-to-ground capacitance must be sufficient to reduce the neutral-voltage shift produced by the integral power module(s) Refer to the nearest S&C Sales Office 3 Includes on-site user training on setup, configuration, and operation of IntelliRupter fault interrupter These services apply to first-time orders only; they can be provided for subsequent orders as indicated in Table 14 on page 15 4 248-kA asymmetrical interrupting and making 5 20-kA asymmetrical interrupting and making Table 2 Disconnect Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters12 Ratings Circuit Diagram kv Max BIL Cont Amperes, RMS Interrupting Symmetrical Catalog Number3 COMPARTMENT-2 Y3 X3 Y2 X2 Y1 X1 L V C 155 27 95 125 630 630 16 0004 12 5005 248822R1 248823R1 COMPARTMENT-1 1 For adequate power to be available from the integral power module(s), the base of the IntelliRupter fault interrupter must be grounded 2 When applied on a system that is not solidly grounded, uni-grounded, grounded through a grounding transformer, or resonant-grounded through a Peterson coil, total system phase-to-ground capacitance must be sufficient to reduce the neutral-voltage shift produced by the integral power module(s) Refer to the nearest S&C Sales Office 3 Includes on-site user training on setup, configuration, and operation of IntelliRupter fault interrupter These services apply to first-time orders only; they can be provided for subsequent orders as indicated in Table 14 on page 15 4 248-kA asymmetrical interrupting and making 5 20-kA asymmetrical interrupting and making 8 S&C Specification Bulletin 766A-31

Table 3 Control Power Source One Control Power Source Must Be Specified Integral power modules for use on 60-Hz systems Integral power modules for use on 50-Hz systems Control Power Source One integral power module fed from one phase on one side One integral power module fed from one phase on one side plus an external power supply1 Two integral power modules fed from a different phase on both sides Two integral power modules fed from a different phase on both sides plus an external power supply1 Voltage Range, kv L-L Suffix to be Added to Catalog Number 75 92 -P161 108 159 -P162 187 274 -P163 160 220 -P164 75 92 -P361 108 159 -P362 187 274 -P363 160 220 -P364 75 92 -P261 108 159 -P262 187 274 -P263 160 220 -P264 75 92 -P461 108 159 -P462 187 274 -P463 160 220 -P464 External power supply only1 -P300 One integral power module fed from one phase on one side One integral power module fed from one phase on one side plus an external power supply1 Two integral power modules fed from a different phase on both sides Two integral power modules fed from a different phase on both sides plus an external power supply1 90 121 -P151 135 196 -P152 180 260 -P153 90 121 -P351 135 196 -P352 180 260 -P353 90 121 -P251 135 196 -P252 180 260 -P253 230 330 -P254 90 121 -P451 135 196 -P452 180 260 -P453 External power supply only1 -P350 1 The external power supply accepts 90-Vac to 259-Vac, 50/60-Hz, primary source input; and accepts 90-Vac to 259-Vac, 50/60-Hz; 19-Vdc to 60-Vdc; or 100-Vdc- to 360-Vdc, secondary source input Table 4 Interrupter Options Suffix to be Added to Catalog Number 155-kV IntelliRupter fault interrupter furnished with interrupters tested and certified to meet 27 kv -Z3 S&C Specification Bulletin 766A-31 9

Table 5 Control Groups One Control Group Must Be Specified Standard Control Group For IntelliTeam SG Automatic Restoration, automatic source transfer, automatic loop restoration, SCADA, and stand-alone (non-communicating) applications Includes IntelliTeam SG Bronze Level Software Optional IntelliTeam SG Silver Level Software provides suitability for basic closed-loop applications Optional IntelliTeam SG Gold Level Software provides suitability for basic closed-loop applications and applications on systems with three or more sources No batteries are required for standalone applications and applications with operating times of 30 seconds or less; ac line voltage must be available on the side of the IntelliRupter fault interrupter with the integral power module or control power must be available from the external power supply, if furnished Specify communication device, if required for the application, from Table 8 on page 12 All team devices must be furnished with the same type of communication device IntelliTeam Designer configuration and license-management software is required to activate IntelliTeam SG software Suffix to be Added to Catalog Number -C0 Standard Control Group with battery backup Identical to the Standard Control Group but additionally includes batteries that support operation for a minimum of four hours after loss of ac line voltage on both sides of IntelliRupter Fault Interrupter, permitting extended dead-line switching Specify communication device, if required for the application, from Table 8 on page 12 All team devices must be furnished with the same type of communication device IntelliTeam Designer configuration and license-management software is required to activate IntelliTeam SG software -C1 Universal Control Group Identical to the Standard Control Group with Battery Backup Includes either IntelliTeam SG Gold Level Software and IntelliTeam Designer Configuration and License Management Software or IntelliTeam II Software License, as specified For the IntelliTeam SG Automatic Restoration System, specify one IntelliTeam Designer Slot part number 008-007006-01 and one IntelliRupter PulseCloser Fault Interrupter Gold License part number 008-007101-01 This license requires an IntelliTeam SG-qualified communication device from the communication device options listed in Table 8 on page 12 For the IntelliTeam II Automatic Restoration System, specify one IntelliTeam Designer Slot part number 008-007006-03 and one IntelliRupter PulseCloser Fault Interrupter IntelliTeam II License part number 008-007106- 01 This license requires an IntelliTeam II-qualified communication device from the communication device options listed in Table 8 on page 12 When ordering enter the selected licenses as separate line items as included in the above and specify communication device, if required for the application, from Table 8 on page 12 All team devices must be furnished with the same type of communication device -C7 The 008-007106-01 license should not to be confused with IntelliTeam SG Automatic Restoration System operating in IntelliTeam II mode An IntelliTeam SG Automatic Restoration System operating in IntelliTeam II mode requires an IntelliTeam SG Automatic Restoration System-qualified communication device 10 S&C Specification Bulletin 766A-31

Table 6 Optional Features Suffix to be Added to Catalog Number Light gray outdoor Ultradur Finishing System finish instead of olive green -A2 Equipment green outdoor finish (Toronto standard) instead of olive green -A3 Seafoam green outdoor finish instead of olive green -A4 Special color outdoor Ultradur Finishing System finish instead of olive green -A5 With olive green outdoor Ultradur Finishing System finish -A10 With light gray outdoor Ultradur Finishing System finish -A12 Stainless steel enclosure1 With equipment green outdoor finish -A13 With seafoam green outdoor finish -A24 With special color outdoor Ultradur Finishing System finish -A15 Hexhead actuator for use in lieu of pentahead actuator on all Penta-Latch Mechanisms -B Key interlock Prevents operation of disconnect unless IntelliRupter fault interrupter is locked open2 -D1 Mounting provisions for fault indicator in cabletermination compartment Note: Accommodates three-phase indicator with singlephase sensors Without viewing window in door -J1 With viewing window in door -J2 Windows in control module cover Permit viewing of status and hot-line tag indicators -V Base spacer Mild steel Stainless steel 6 inches (152 mm) -K7 12 inches (305 mm) -K8 6 inches (152 mm) -K17 12 inches (305 mm) -K18 600-Ampere bushings without studs -M1 Provisions for remote pole-mounted antenna Includes PolyPhaser surge suppressor with female N-Type connector mounted in low-voltage compartment Ten-year IntelliRupter fault interrupter warranty In lieu of standard two-year warranty Matches standard 10-year warranty for control groups Does not include enclosure Spanish -L51 Portuguese -L52 -S3 -T1 Foreign language labels, and screens3 French -L53 Chinese -L54 Arabic -L55 International crating Wood products used in packaging are either hardwood or certified by the wood supplier as being heat treated (kiln dried) to a core temperature of 133 F (58 C) for a minimum of 30 minutes -L71 1 When this optional feature is specified, the entire exterior of the enclosure will be fabricated from 11-gauge Type 304 stainless steel When ordering optional hexhead actuators, provisions for fault indicators with viewing windows in doors, or base adapter, specify the correct suffix for use with a stainless-steel enclosure 2 When ordering, please furnish name of the end user and the location of gear 3 All labels are available Contact the nearest S&C Sales Office for screen availability Table 7 Special Optional Feature Suffix to be Added to Catalog Number Reversed colors for IntelliRupter fault interrupter OPEN/CLOSED indicators and OPEN/CLOSED/READY lever (green for closed, red for open) -F2 S&C Specification Bulletin 766A-31 11

Table 8 Communication Devices for IntelliTeam SG, IntelliTeam II, Automatic Source Transfer, and SCADA Applications Suffix to be Added to Catalog Number Communication Devices Suitable For IntelliTeam SG, IntelliTeam II, Automatic Source Transfer, and SCADA Applications1 Factory-installed and wired S&C SpeedNet Radio, providing high-speed network communication via DNP 30 protocol and a 900-MHz, 3-dBi gain antenna2 -R80 Factory-installed and wired SpeedNet SDR 4 Software Defined Radio5 -R254 Factory-installed and wired SpeedNet SDR 4x4 Software Defined Radio5 -R256 Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 100-Mbps multi-mode LC transceiver 550 m, 850 nm, low-voltage (Input 9-36 Vdc) Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 100-Mbps multi-mode LC transceiver 2 km, 1310 nm, low-voltage (Input 9-36 Vdc) Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 100-Mbps single mode LC transceiver 10 km, 1310 nm, low-voltage (Input 9-36 Vdc) Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 100-Mbps single mode LC transceiver 30 km, 1310 nm, low-voltage (Input 9-36 Vdc) Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 100-Mbps single mode LC transceiver 60 km, 1310 nm, low-voltage (Input 9-36 Vdc) Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 120-Mbps single mode LC transceiver 100 km, 1550 nm, low-voltage (Input 9-36 Vdc) Factory-installed and wired is5 Comm Inc - ies6-module with 2-SFP 100-Mbps single mode LC transceiver 120 km, 1550 nm, low-voltage (Input 9-36 Vdc) -R278 -R279 -R280 -R281 -R282 -R283 -R284 Factory-installed and wired SpeedNet Radio and SpeedNet Cell Edge Gateway6 -R322 Provisions only for SpeedNet SDR 4 Software Defined Radio5 -R255 Provisions only for SpeedNet SDR 4x4 Software Defined Radio5 -R257 Provision only for is5 Comm Inc - ies6-module multimode LC transceiver use - Customer must provide an ies6 module with 2-SFP LC transceivers -R276 Provision only for is5 Comm Inc - ies6-module single-mode LC transceiver use - Customer must provide an ies6 module with 2-SFP LC transceivers -R277 Communication devices suitable for automatic source transfer and SCADA applications only Factory-installed and wired SpeedNet ME Mesh End-Point Radio -R240 Provisions only for SpeedNet ME Mesh End-Point Radio -R241 Factory-installed and wired SpeedNet Cell Edge Gateway7 -R320 Provision only for single-mode Dymec 5843SHRT fiber-optic modem3 -R42 Provision only for multi-mode Dymec 5843HRT fiber-optic modem4 -R43 Factory-installed and wired MDS TransNET 900 transceiver and 900-MHz, 3-dBi gain antenna2 -R18 Factory-installed and wired MDS TransNET 900 transceiver with diagnostics and 900-MHz, 3-dBi gain antenna2 -R19 1 These are the only wide-area network communication devices approved for use with the IntelliTeam SG Automatic Restoration system For other communication devices, refer to the nearest S&C Sales Office 2 Antenna mounts directly to the roof of the low-voltage compartment If a remote pole-mounted antenna is desired instead, see Table 6 on page 11 3 A Single-Mode Mating Connector and Termination Kit must be specified See Table 9 on page 13 4 A Multi-Mode Mating Connector and Termination Kit must be specified See Table 9 on page 13 5 Please see Specification bulletin 1075-31 for SpeedNet SDR 4 and SpeedNet SDR 4X4 radio-antenna options 6 Please see Specification Bulletin 1072-31 for SpeedNet Radio antenna options and 1076-31 for SpeedNet Cell Edge Gateway antenna options 7 Please see Specification Bulletin 1076-31 for SpeedNet Cell Edge Gateway antenna options 12 S&C Specification Bulletin 766A-31

Table 9 Fiber-Optic Connection Accessories Single-mode mating connector and termination kit Includes connector hood, inserts, and fiber termination components Multi-mode mating connector and termination kit Includes connector hood, inserts, and fiber termination components Catalog Number SD-6607 SD-6608 Table 10 Connector (For enclosure ground) Illustration Description Accommodating Conductor Catalog Number Bronze body, tin plated, two galvanized steel bolts, two Belleville washers No 2 solid through 500 kc mil (335 mm 2 ) stranded copper or aluminum 4745 S&C Specification Bulletin 766A-31 13

Table 11 Accessories Description Battery charger output harness For connecting battery pack to an 800-mA, current-limited 12-Vdc lead-acid battery charger Pre-configured laptop computer a 14-inch Dell computer with 2-MB RAM, 80-GB hard drive, and factory-loaded IntelliLink Setup Software (not available for sale outside the United States) Wi-Fi tester Simulates connection to communication module Confirms user s laptop computer is properly configured to establish secure Wi-Fi connection to IntelliRupter fault interrupter Also demonstrates use of Wi-Fi security keys For indoor use only, in user s service center or lab Remote antenna kit Includes a unidirectional Yagi antenna, a pole-mounted single antenna arm, and a 50-foot (1524 cm) coaxial cable with N-Type male connectors on both ends Detailed instruction manual Binder containing printed copies of all IntelliRupter fault interrupter instruction sheets, erection drawings, and reference drawings Spare protection and control module Spare communication module less battery pack and radio Spare 12-Vdc, 8-ampere-hour battery pack for communication module Docking station Powers the protection and control module and the communication module, removed from IntelliRupter fault interrupter base Permits uploading and downloading of configuration settings plus programming of radio and charging of radio batteries, as applicable, in user s service center or lab Power supply Attaches to an external power supply connector Powers the protection and control module and the communication module, for pre-installation uploading and downloading of configuration settings plus radio programming and battery charging, as applicable For indoor use only in user s service center or lab Input voltage range is 88-264 Vac, 50/60 Hz Catalog Number 007-001551-01 SDA-5697 908-000961-01 903-002321-03 RD-6949 SDA-4540R2 SDA-4554-1 SDA-4605 SDA-4650R2 TA-3221 Shotgun clamp sticks for use with separable connectors and voltage testers Storage bag for shotgun clamp stick, heavy canvas 6-feet 5½-inch (197-cm) length 9933-150 8-feet 5½-inch (258-cm) length 9933-151 6-feet 6-inch (198-cm) length 9933-152 8-feet 6-inch (259-cm) length 9933-153 Voltage tester with audio and visual signals, includes a voltage tester, batteries, an adapter for shotgun clamp sticks, and a storage case1 9931-072 Pentahead socket, for ½-inch drive 9931-074 is5 Comm Inc - ies6-module only with conformal coating, power terminal block and DB9 console cable, low-voltage (Input 9-36 Vdc), LC connector 110-003780-01 SFP 100-Mbps multimode LC transceiver 550 m, 850 nm 110-003774-01 SFP 100-Mbps multimode LC transceiver 2 km, 1310 nm 110-003774-02 SFP 100-Mbps single-mode LC transceiver 10 km, 1310 nm 110-003774-04 SFP 100-Mbps single-mode LC transceiver 30 km, 1310 nm 110-003774-05 SFP 100-Mbps single-mode LC transceiver 60 km, 1310 nm 110-003774-06 SFP 100-Mbps single-mode LC transceiver 100 km, 1550 nm 110-003774-07 SFP 100-Mbps single-mode LC transceiver 120 km, 1550 nm 110-003774-08 is5 Comm Inc ies22gf industrial Ethernet switch, High voltage (Input 130-370VDC or 90-264VAC), 8-10/100/1000 Base TX RJ45 Ports, 4 - GSFP is5 Comm Inc ies22gf industrial Ethernet switch, Low voltage (Input 9-36 Vdc), 8-10/100/1000 Base TX RJ45 Ports, 4 - GSFP is5 Comm Inc ids3 industrial single port RS232/422/485 to Ethernet serial device server, Low voltage (Input 9-36 Vdc), 1-serial port, 2-10/100 Base TX RJ45 Ports 110-003777-01 110-003778-01 110-003779-01 1 For ultimate users other than electric utilities, also specify a shotgun clamp stick of the appropriate length 14 S&C Specification Bulletin 766A-31

Table 12 Touch-Up Kit Components Aerosol Coatings in 12-ounce cans Catalog Number S&C light gray outdoor finish 9999-080 S&C olive green (Munsell 7GY329/15) outdoor finish 9999-058 S&C red-oxide primer 9999-061 Table 13 IntelliRupter PulseCloser Fault Interrupter/Services Packages 155-kV IntelliRupter PulseCloser Fault Interrupter/Services Packages Each package includes Non-Disconnect Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters Catalog Number 248812-P262-C1-R80 or 248812-P262-C1-R201 Each IntelliRupter fault interrupter includes two Integral power modules for use on 1143-kV to 155-kV, 60-Hz systems, Standard Control Group with Battery Backup, and SpeedNet Radio One SpeedNet Extension-Arm-Mounted Repeater Radio is also included Services furnished include a communication site survey, IntelliTeam SG factory acceptance testing, IntelliRupter fault interrupter training, IntelliTeam SG training, and IntelliTeam SG commissioning 27-kV IntelliRupter PulseCloser Fault Interrupter/Services Packages Each package includes Non-Disconnect Pad-Mounted Style IntelliRupter PulseCloser Fault Interrupters Catalog Number 248813-P263-C1-R80 or 248813-P263-C1-R201 Each IntelliRupter fault interrupter includes two Integral power modules for use on 1881-kV to 27-kV, 60-Hz systems, Standard Control Group with Battery Backup, and SpeedNet Radio One SpeedNet Extension-Arm-Mounted Repeater Radio is also included Services furnished include a communication site survey, IntelliTeam SG factory acceptance testing, IntelliRupter fault interrupter training, IntelliTeam SG training, and IntelliTeam SG commissioning Three-member team Four-member team Five-member team Six-member team Seven-member team Eight-member team Nine-member team Ten-member team Eleven-member team Twelve-member team Table 14 IntelliRupter Fault Interrupter Services Packages Communication site survey Field testing to confirm the user-proposed IntelliRupter fault interrupter locations will provide acceptable communication between team members and the head-end SCADA radio, if applicable The user should make available their engineer/technician responsible for the project IntelliTeam SG training On-site training on functioning of the IntelliTeam SG Automatic Restoration System Includes operations and engineering training sessions IntelliTeam SG commissioning Ensures IntelliRupter fault interrupters have been set up correctly and IntelliTeam SG is ready to be put into service IntelliTeam SG SCADA integration Includes review of the user s SCADA system, development of DNP points lists, coordination with the user s SCADA supplier, and review of the SCADA database IntelliTeam SG factory acceptance testing Factory testing ensures all information required for successful IntelliTeam SG implementation is gathered and understood before commissioning Provides insight into how the IntelliTeam SG Automatic Restoration System will work on the user s system The user must travel to Chicago to witness the testing IntelliTeam SG monitoring Factory testing ensures all information required for successful IntelliTeam SG implementation is gathered and understood before commissioning Provides insight into how the IntelliTeam SG Automatic Restoration System will work on the user s system The user must travel to Chicago to witness the testing IntelliRupter Fault Interrupter maintenance Includes inspection, testing, and battery replacement on a threeyear interval IntelliRupter Fault Interrupter project and construction management Determination of appropriately rated protective devices and their settings, including those of IntelliRupter fault interrupters Proper coordination minimizes the impact of short-circuits by isolating faults as quickly as possible while maintaining power to the rest of the system Overcurrent Protective Device Coordination Study Determination of appropriately rated protective devices and their settings, including those of IntelliRupter fault interrupters Proper coordination minimizes the impact of shortcircuits, by isolating faults as quickly as possible, while maintaining power to the rest of the system IntelliTeam SG device settings determination Determination of these settings is essential to the successful implementation of the IntelliTeam SG Automatic Restoration System and must be documented before factory acceptance testing and commissioning Loop-restoration training Covers setup, configuration, and operation of IntelliRupter fault interrupters in a loop application comprised of normally closed IntelliRupter fault interrupters or conventional reclosers with a normally open IntelliRupter Fault Interrupter switching point IntelliRupter Fault Interrupter training Covers the IntelliLink Setup Software; configuring the IntelliRupter fault interrupter for use in an IntelliTeam SG, source-transfer, or loop restoration system, as appropriate; use of security keys; and operation Catalog Number AS100 AS101 AS102 AS103 AS104 AS105 AS106 AS107 AS108 AS109 AS110 AS111 S&C Specification Bulletin 766A-31 15