Supplemental Protectors

Similar documents
Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

60103 Circuit Breaker

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

1492-SP Supplementary Protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Jtec 10kA Miniature Circuit Breaker

UL 489 DIN rail branch circuit breakers

Miniature Circuit Breakers and Supplementary Protectors. Contents

Introduction Circuit Protection

9926 Series Branch Rated Circuit Breakers AC Version

WMS SUPPLEMENTARY PROTECTORS

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

US BROCHURE. Circuit protection according to UL 489 and UL 1077

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Product Guide. UL 1077 DIN Rail Supplementary Protectors

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

TeSys IEC Contactors and Overload Relays

Supplementary Circuit Protectors Type GSB63

MULTI 9 System Catalog

UL 489 DIN Rail Miniature Circuit Breakers

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Selection Guide. Control Circuit and Load Protection

Bulletin 1489 Circuit Breakers. Selection Guide

UL 489 DIN Rail Miniature Circuit Breakers

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Multi 9 System Catalog

Selection Guide. Control Circuit and Load Protection

Allen-Bradley 1492-RCDA4A40

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Control Circuit and Load Protection Products

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Protection Equipment

Section 4 Ground-Fault Protection Devices

Introduction Electronic Circuit Protection ESX10-T

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Applying branch circuit breakers and supplementary protectors in North America

CS8 Industrial Control Relays

Product Guide. UL 489 DIN rail miniature circuit breakers

MULTI 9 System Catalog

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

US Catalog July 2016 SMISSLINE TP

Circuit Breakers Type CTI 25M, CTI 45MB

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Applying branch circuit breakers and supplementary protectors in North America

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Thermal-Magnetic Circuit Breaker 2216-S

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Go to:

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Mini Contactors & Overloads

US CATALOG SMISSLINE TP

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Miniature Circuit Breakers for Railway Applications

CS7 Industrial Control Relays

Motor protection relays

For Sales and Support call KMParts.com (866)

DSE201, DSE201 M Compact design with enhanced protection

Overvoltage Protection

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

CS7 Industrial Control Relays

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Circuit and Surge Protection Protection Solutions Catalog. North America

Time Delay Values (E-Series)

MOTOR PROTECTION CIRCUIT BREAKERS

3 Pole Contactors with AC operating coils

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Solid-State Switching Devices

PERCENT OF RATED CURRENT

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

920 Remote Control (RC) Switches

CERTIFICATE OF COMPLIANCE

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

Miniature Circuit-Breaker IEC Series 8562

Non-Fusible Disconnect Switches

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

IELR Rail-Mount Series Magnetic Circuit Protectors

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

C-Series. Circuit Breaker

78 Series Electromechanical Relay Selection Guide

IELR Series

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Motor protection circuit breakers

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

ASCO 920 Remote Control (RC) Switches

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Transcription:

compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are current limiting, DIN rail mounted and can offer a good equivalent to fused systems. The S2 is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to B, C, D, K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. Features Current limiting Fast breaking time (2.5 3.5 msec) Unique bus connection system Wide range of accessories Available with variable depth handle mechanism Optional Z curve for SCR protection CE certified and marked DIN rail or front panel mounting Finger safe terminals Multi-function terminals Suitable for reverse feed 480Y/277VAC and 500VDC versions UL489 Listed - branch circuit protective device. UL file # E22323 UL077 Recognized - supplemental protective device. UL file # E7626 UL Approved Miniature Molded Case Circuit Breakers and Supplemental Protectors Low Voltage Products & Systems.

S200 Series General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are approved for use by Underwriters Laboratories in systems rated up to 600VAC/VDC. Devices are also certified per CSA. MCBs are approved per IEC-898 and VDE 064, and certified under IEC-947 and VDE 0660 standards for use in systems rated up to 690VAC. MCBs can be applied to 6 2/3Hz 400Hz and DC power systems. Special direct current version MCBs include a permanent magnet for DC fault current interruption. These "UC" versions are rated 250/500VDC under UL077/CSA 22.2 No. 235. Continuous current ratings are as low as 0.2 amperes and up to 25 amperes maximum. MCBs are of compact size and can be quickly mounted on standard 35mm DIN rail or can be front mounted by use of a front mounting kit. MCBs include line and load side terminals for conductors from 8 through 4AWG (0.75 25mm 2 ) for 63 amperes. MCBs can also be connected via busbar conductors which can be either upper or lower mounted for top feed or bottom feed. Dual function terminals allow busbars to be connected with main incoming line conductors without separate lugs. Accessories Auxiliary devices can be added to the, S200 series MCBs: Shunt trips Auxiliary contacts Bell alarm contacts Aux/bell alarm contacts Undervoltage release Accessory device modules can be field mounted to all above listed ABB MCBs. Auxiliary contacts are also available for the S500 series MCB. Applications MCBs can be used for equipment protection, in commercial appliances, protection of control circuits against overcurrent faults, computer equipment and other computer peripheral devices. UL 489 S200U and S200UP MCBs are listed as molded case circuit breakers for use as branch circuit protective devices. Miniature MCCBs and accessories are listed under UL file E22323. UL 077 S200 and S200P MCBs are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided or not required. MCBs and accessories are recognized under UL File E7626. CSA C22.2 MCBs and accessories are certified under CSA C22.2 No. 235 per File LR98793. Tripping characteristics Time-current curves ABB miniature circuit breakers are available with different trip characteristics, allowing for maximum system protection. B Characteristic Available with the S200 and S500 series has rated currents of 6 through 63 amperes in 0 steps. The "B" time-current curve is designed primarily for use in cable protection applications. Instantaneous tripping occurs between approximately 3 to 5 times rated current in 50/60Hz systems. This quick trip curve maximizes protection of control circuits under low short circuit fault levels that could damage control wiring. C Characteristic Available in the S200 and S500 series with rated currents up through 63 amperes and the S290 series with rated currents of 80, 00 and 25 amperes. The "C" time-current curve is designed for medium magnetic start-up currents. Instantaneous tripping occurs between 5 and 0 times rated current in 50/60 Hz systems. D Characteristic The new magnetic trip action has an instantaneous trip between 0 and 20 times the breaker rating. Thus, the S200 and S500-D can be a good protective solution for applications involving high in-rush transformers, motors and other high inductive systems. It is also suitable for any application where a high instantaneous trip point is desired. K Characteristic The "K" time-current characteristic considers high magnetic start-up currents from motors, transformers and other equipment. Instantaneous tripping occurs between 8 and 2 times rated current in 50/60Hz systems. The "K" characteristic is available up through 63 amperes. The "K" curve offers the best protection for the broadest range of electrical systems. The higher magnetic trip settings maximizes protection while allowing for higher in-rush currents during system startup. Available in S200P, S200U, S200UP and S500. Z Characteristic Also available up through 63 amperes, the "Z" characteristic offers instantaneous tripping between 2 and 3 times rated current in 50/60Hz systems. This trip characteristic is available in the S200P, S200U and S200UP series with both the 480Y/277VAC and 250/500VDC ratings. Many applications require a very low short circuit trip setting in order to protect semiconductor or other sensitive devices and the "Z" trip characteristic may provide maximum protection and service in these applications..2 Low Voltage Products & Systems

General information Interruption ratings Trip characteristics overview S200 Series Interruption ratings Voltage Rated interrupting Rated MCB capacity current type Comment 20 VAC 0kA 0.5-63A S200-B,C,D 0.5-63A S200-K 0.2-63A S200P-K, Z 0.2-63A S200U-K, Z 0.2-25A S200UP-K, Z 8kA 32-63A S500-B,C,D 26-45A S500-K 30kA 6-25A S500-B,C,D 0.5-25A S500-K 240 VAC 6kA 0.5-63A S200-B,C,D Single pole 0.5-63A S200-K Single pole 0kA 0.5-63A S200-B,C,D Multi pole 0.5-63A S200-K Multi pole 0.2-63A S200P-K,Z Single pole 0.2-63A S200P-K,Z Multi pole 0.2-63A S200U-K,Z Single pole 0.2-63A S200U-K,Z Multi pole 0.2-25A S200UP-K,Z Single pole 0.2-25A S200UP-K,Z Multi pole 8kA 32-63A S500-B,C,D 26-45A S500-K 30kA 6-25A S500-B,C,D 0.5-25A S500-K 277 VAC 6kA 0.5-63A S200-B,C,D 0.5-63A S200-K 0KA 0.2-63A S200P-K,Z 0.2-25A S200UP-K,Z 480Y/277 VAC 6kA 0.5-63A S200-B,C,D 0.5-63A S200-K 0KA 0.2-63A S200P-K,Z 0.2-25A S200UP-K,Z 60 VDC 0kA 0.5-63A S200-B,C,D Single pole 0.5-63A S200-K Single pole 25 VDC 0kA 0.5-63A S200-B,C,D Multi pole 0.5-63A S200-K Multi pole 0.2-63A S280UC-K,Z Single pole 250 VDC 4.5kA 0.2-63A S280UC-K,Z Single pole 500 VDC 4.5kA 0.2-63A S280UC-K,Z Multi pole Trip characteristics overview Curve Magnetic Thermal characteristic characteristic Series B 3-5X.3.45X S200, S500 C 5-0X.3.45X S200, S290, S500 D 0-20X.3.45X S200, S500 K 8-2X.05.20X S200, S500 Z 2-3X.05.20X S200 All values are relative to MCB's ampere rating. Low Voltage Products & Systems.3

S200 Series General information Tripping curves 0,000 5000 B 0,000 5000 C 0,000 5000 D 000 500 000 500 000 500 00 50 00 50 00 50 0 5 0 5 0 5 seconds 0.5 0. 0.05 AC DC seconds 0.5 0. 0.05 AC DC seconds 0.5 0. 0.05 AC DC 0.0 0.0 0.0 2 3 5 7 0 20 30 multiple of rated current 2 3 5 0 8 20 30 multiple of rated current 2 3 5 0 20 30 multiple of rated current 0,000 5000 K 0,000 5000 UC-K 000 500 000 500 00 50 00 50 0 5 0 5 seconds 0.5 0. 0.05 AC DC seconds 0.5 0. 0.05 DC 0.0 0.0 2 3 5 8 02 20 30 multiple of rated current 2 3 5 0 20 30 multiple of rated current 0,000 5000 Z 0,000 5000 UC-Z 000 500 000 500 00 50 00 50 0 5 0 5 seconds 0.5 0. 0.05 AC DC seconds 0.5 0. 0.05 DC 0.0 0.0 2 3 5 0 20 30 2 3 5 0 20 30 multiple of rated current multiple of rated current.4 Low Voltage Products & Systems

General information Construction details S200 Series Electro-magnetic protection Tripping lever Upper terminal Operating mechanism Thermal protection-bimetal Operator Arc chamber Space for identification marker Fixed contact Moving contact DIN rail holder Lower terminal Low Voltage Products & Systems.5

B S200 Series UL 077 CSA C22.2 No. 235 VDE 064 IEC-898 Cable protection S200 480Y/277 VAC Supplemental protectors S20-B, pole S202-B, 2 pole S20-BNA, P+N S203-B, 3 pole Rated Catalog List Delivery current number price class pole 6 S20-B6 $ 36 0 S20-B0 36 3 S20-B3 36 6 S20-B6 36 20 S20-B20 38 25 S20-B25 38 32 S20-B32 40 40 S20-B40 42 50 S20-B50 48 63 S20-B63 56 pole + neutral A 0 4.5 6 S20-B6NA 62 0 S20-B0NA 62 3 S20-B3NA 62 6 S20-B6NA 62 20 S20-B20NA 68 25 S20-B25NA 72 B 5 9.0 32 S20-B32NA 74 40 S20-B40NA 76 50 S20-B50NA 90 63 S20-B63NA 02 2 pole 6 S202-B6 78 0 S202-B0 78 3 S202-B3 78 6 S202-B6 78 20 S202-B20 86 25 S202-B25 88 32 S202-B32 94 40 S202-B40 98 50 S202-B50 2 63 S202-B63 28 Sugg. order qty Wgt. oz. ( pc.) A 5 9.0 Rated Catalog List Delivery current number price class 3 pole 6 S203-B6 $ 8 0 S203-B0 8 3 S203-B3 8 6 S203-B6 8 20 S203-B20 30 25 S203-B25 32 32 S203-B32 2 40 S203-B40 8 50 S203-B50 70 63 S203-B63 94 3 pole + neutral A 3.5 6 S203-B6NA 2 0 S203-B0NA 2 3 S203-B3NA 2 6 S203-B6NA 2 20 S203-B20NA 62 25 S203-B25NA 68 B 8.0 32 S203-B32NA 76 40 S203-B40NA 84 50 S203-B50NA 22 63 S203-B63NA 240 4 pole 6 S204-B6 56 0 S204-B0 56 3 S204-B3 56 6 S204-B6 56 20 S204-B20 72 25 S204-B25 76 32 S204-B32 88 40 S204-B40 96 50 S204-B50 224 63 S204-B63 256 Sugg. order qty B 8.0 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) S204-B, 4 pole S203-BNA, 3P+N 0,000 5000 B 000 500 00 50 0 5 seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 7 0 20 30 multiple of rated current.6 Discount schedule CB5 Low Voltage Products & Systems

S200 480Y/277 VAC Supplemental protectors S200 Series C UL 077 CSA C22.2 - NO. 235 VDE 064 IEC-898 Cable & equipment protection 0,000 5000 000 500 S20-C, pole S202-C, 2 pole S20-CNA, P+N S203-C, 3 pole S204-C, 4 pole S203-CNA, 3P+N C Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty pole 0.5 S20-C0.5 $ 42 S20-C 42.6 S20-C.6 42 2 S20-C2 42 3 S20-C3 42 4 S20-C4 42 6 S20-C6 42 8 S20-C8 42 0 S20-C0 42 A 0 4.5 3 S20-C3 42 6 S20-C6 42 20 S20-C20 42 25 S20-C25 46 32 S20-C32 48 40 S20-C40 52 50 S20-C50 60 63 S20-C63 68 pole + neutral 0.5 S20-C0.5NA 84 S20-CNA 84.6 S20-C.6NA 84 2 S20-C2NA 84 3 S20-C3NA 84 4 S20-C4NA 84 6 S20-C6NA 84 8 S20-C8NA 84 0 S20-C0NA 84 3 S20-C3NA 84 6 S20-C6NA 84 20 S20-C20NA 84 25 S20-C25NA 88 32 S20-C32NA 90 40 S20-C40NA 96 50 S20-C50NA 2 63 S20-C63NA 30 2 pole 0.5 S202-C0.5 96 S202-C 96.6 S202-C.6 96 2 S202-C2 96 3 S202-C3 96 4 S202-C4 96 6 S202-C6 96 8 S202-C8 96 0 S202-C0 96 3 S202-C3 96 6 S202-C6 96 20 S202-C20 96 25 S202-C25 06 32 S202-C32 06 40 S202-C40 6 50 S202-C50 36 63 S202-C63 52 B 5 9.0 A 5 9.0 Rated Catalog List Delivery current number price class 3 pole 0.5 S203-C0.5 $ 38 S203-C 38.6 S203-C.6 38 2 S203-C2 38 3 S203-C3 38 4 S203-C4 38 6 S203-C6 38 8 S203-C8 38 0 S203-C0 38 3 S203-C3 38 6 S203-C6 38 20 S203-C20 38 25 S203-C25 56 32 S203-C32 58 40 S203-C40 74 50 S203-C50 200 63 S203-C63 228 3 pole + neutral 0.5 S203-C0.5NA 200 S203-CNA 200.6 S203-C.6NA 200 2 S203-C2NA 200 3 S203-C3NA 200 4 S203-C4NA 200 6 S203-C6NA 200 8 S203-C8NA 200 0 S203-C0NA 200 3 S203-C3NA 200 6 S203-C6NA 200 20 S203-C20NA 200 25 S203-C25NA 206 32 S203-C32NA 22 40 S203-C40NA 224 50 S203-C50NA 204 63 S203-C63NA 304 4 pole 0.5 S204-C0.5 28 S204-C 28.6 S204-C.6 28 2 S204-C2 28 3 S204-C3 28 4 S204-C4 28 6 S204-C6 28 8 S204-C8 28 0 S204-C0 28 3 S204-C3 28 6 S204-C6 28 20 S204-C20 28 25 S204-C25 234 32 S204-C32 238 40 S204-C40 260 50 S204-C50 300 63 S204-C63 338 Sugg. order qty Wgt. oz. ( pc.) A 3.5 B 8.0 B 8.0 00 50 0 5 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 0 8 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB5.7

S200 Series S200 480Y/277 VAC Supplemental protectors D UL 077 CSA C22.2 VDE 064 IEC-898 Cable & equipment protection Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) S20-D, pole S202-D, 2 pole pole 0.5 S20-D0.5 $ 42 S20-D 42.6 S20-D.6 42 2 S20-D2 42 3 S20-D3 42 4 S20-D4 42 6 S20-D6 42 8 S20-D8 42 0 S20-D0 42 A 0 4.5 3 S20-D3 42 6 S20-D6 42 20 S20-D20 42 25 S20-D25 46 32 S20-D32 48 40 S20-D40 52 50 S20-D50 60 63 S20-D63 68 2 pole 0.5 S202-D0.5 96 S202-D 96.6 S202-D.6 96 2 S202-D2 96 3 S202-D3 96 4 S202-D4 96 6 S202-D6 96 8 S202-D8 96 0 S202-D0 96 3 S202-D3 96 6 S202-D6 96 20 S202-D20 96 25 S202-D25 06 32 S202-D32 06 40 S202-D40 6 50 S202-D50 36 63 S202-D63 52 A 5 9.0 3 pole 0.5 S203-D0.5 $ 38 S203-D 38.6 S203-D.6 38 2 S203-D2 38 3 S203-D3 38 4 S203-D4 38 6 S203-D6 38 8 S203-D8 38 A 3.5 0 S203-D0 38 3 S203-D3 38 6 S203-D6 38 20 S203-D20 38 25 S203-D25 56 32 S203-D32 58 40 S203-D40 74 50 S203-D50 200 63 S203-D63 228 S203-D, 3 pole 0,000 5000 D 000 500 00 50 0 5 seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 0 20 30 multiple of rated current.8 Discount schedule CB5 Low Voltage Products & Systems

S200 480Y/277 VAC Supplemental protectors S200 Series K UL 077 CSA C22.2 - NO. 235 VDE 064 IEC-898 Cable & equipment protection seconds 0,000 5000 000 500 00 50 0 5 0.5 0. 0.05 S20-K, pole S202-K, 2 pole S20-KNA, P+N S203-K, 3 pole S204-K, 4 pole S203-KNA, 3P+N K AC DC Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty pole 0.5 S20-K0.5 $ 42 S20-K 42.6 S20-K.6 42 2 S20-K2 42 3 S20-K3 42 4 S20-K4 42 5 S20-K5 42 6 S20-K6 42 8 S20-K8 42 0 S20-K0 42 3 S20-K3 42 A 0 4.5 5 S20-K5 42 6 S20-K6 42 20 S20-K20 42 25 S20-K25 46 30 S20-K30 48 32 S20-K32 48 40 S20-K40 52 50 S20-K50 60 60 S20-K60 68 63 S20-K63 68 pole + neutral 0.5 S20-K0.5NA 84 S20-KNA 84.6 S20-K.6NA 84 2 S20-K2NA 84 3 S20-K3NA 84 4 S20-K4NA 84 6 S20-K6NA 84 8 S20-K8NA 84 0 S20-K0NA 84 B 5 9.0 3 S20-K3NA 84 6 S20-K6NA 84 20 S20-K20NA 84 25 S20-K25NA 88 32 S20-K32NA 90 40 S20-K40NA 96 50 S20-K50NA 2 63 S20-K63NA 30 2 pole 0.5 S202-K0.5 96 S202-K 96.6 S202-K.6 96 2 S202-K2 96 3 S202-K3 96 4 S202-K4 96 5 S202-K5 96 6 S202-K6 96 8 S202-K8 96 0 S202-K0 96 A 5 9.0 3 S202-K3 96 5 S202-K5 96 6 S202-K6 96 20 S202-K20 96 25 S202-K25 06 30 S202-K30 06 32 S202-K32 06 40 S202-K40 6 50 S202-K50 36 60 S202-K60 52 63 S202-K63 52 Rated Catalog List Delivery current number price class 3 pole Sugg. order qty Wgt. oz. ( pc.) 0.5 S203-K0.5 $ 38 S203-K 38.6 S203-K.6 38 2 S203-K2 38 3 S203-K3 38 4 S203-K4 38 5 S203-K5 38 6 S203-K6 38 8 S203-K8 38 0 S203-K0 38 3 S203-K3 38 A 3.5 5 S203-K5 38 6 S203-K6 38 20 S203-K20 38 25 S203-K25 56 30 S203-K30 58 32 S203-K32 58 40 S203-K40 74 50 S203-K50 200 60 S203-K60 228 63 S203-K63 228 3 pole + neutral 0.5 S203-K0.5NA 200 S203-KNA 200.6 S203-K.6NA 200 2 S203-K2NA 200 3 S203-K3NA 200 4 S203-K4NA 200 6 S203-K6NA 200 8 S203-K8NA 200 0 S203-K0NA 200 B 8.0 3 S203-K3NA 200 6 S203-K6NA 200 20 S203-K20NA 200 25 S203-K25NA 206 32 S203-K32NA 22 40 S203-K40NA 224 50 S203-K50NA 264 63 S203-K63NA 304 4 pole 0.5 S204-K0.5 28 S204-K 28.6 S204-K.6 28 2 S204-K2 28 3 S204-K3 28 4 S204-K4 28 6 S204-K6 28 8 S204-K8 28 B 8.0 0 S204-K0 28 3 S204-K3 28 6 S204-K6 28 20 S204-K20 28 25 S204-K25 234 32 S204-K32 238 40 S204-K40 260 50 S204-K50 300 63 S204-K63 338 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 0.0 2 3 5 8 02 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB5.9

S200 Series S200P 480Y/277 VAC Supplemental protectors K UL 077 CSA C22.2 - NO. 235 VDE 0660 Cable & equipment protection S20P-K, pole S202P-K, 2 pole S203P-K, 3 pole Rated Catalog List Delivery current number price class pole 0.2 S20P-K0.2 $ 54 0.3 S20P-K0.3 54 0.5 S20P-K0.5 54 0.75 S20P-K0.75 54 S20P-K 54.6 S20P-K.6 54 2 S20P-K2 54 3 S20P-K3 54 4 S20P-K4 54 6 S20P-K6 54 8 S20P-K8 54 A 0 4.6 0 S20P-K0 54 3 S20P-K3 54 6 S20P-K6 54 20 S20P-K20 54 25 S20P-K25 56 32 S20P-K32 58 40 S20P-K40 64 50 S20P-K50 70 63 S20P-K63 80 2 pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S202P-K0.2 28 0.3 S202P-K0.3 28 0.5 S202P-K0.5 28 0.75 S202P-K0.75 28 S202P-K 28.6 S202P-K.6 28 2 S202P-K2 28 3 S202P-K3 28 4 S202P-K4 28 6 S202P-K6 28 A 5 9.2 8 S202P-K8 28 0 S202P-K0 28 3 S202P-K3 28 6 S202P-K6 28 20 S202P-K20 28 25 S202P-K25 30 32 S202P-K32 34 40 S202P-K40 34 50 S202P-K50 62 63 S202P-K63 82 Rated Catalog List Delivery current number price class 3 pole 0.2 S203P-K0.2 $ 94 0.3 S203P-K0.3 94 0.5 S203P-K0.5 94 0.75 S203P-K0.75 94 S203P-K 94.6 S203P-K.6 94 2 S203P-K2 94 3 S203P-K3 94 4 S203P-K4 94 6 S203P-K6 94 A 3.9 8 S203P-K8 94 0 S203P-K0 94 3 S203P-K3 94 6 S203P-K6 94 20 S203P-K20 94 25 S203P-K25 96 32 S203P-K32 200 40 S203P-K40 2 50 S203P-K50 246 63 S203P-K63 280 Delivery Class Sugg. order qty A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) 0,000 5000 K 000 500 00 50 0 5 seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 8 02 20 30 multiple of rated current.0 Discount schedule CB7 Low Voltage Products & Systems

S280 (W) 480Y/277 VAC Supplemental protectors S200 Series K UL 077 CSA C22.2 - NO. 235 VDE 0660 Cable & equipment protection S28-KW, pole S282-KW, 2 pole S283-KW, 3 pole Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) pole 0.2 S28-K0.2W $ 54 0.3 S28-K0.3W 54 0.5 S28-K0.5W 54 0.75 S28-K0.75W 54 S28-KW 54.6 S28-K.6W 54 2 S28-K2W 54 3 S28-K3W 54 4 S28-K4W 54 6 S28-K6W 54 8 S28-K8W 54 B 0 4.6 0 S28-K0W 54 3 S28-K3W 54 6 S28-K6W 54 20 S28-K20W 54 25 S28-K25W 56 32 S28-K32W 58 40 S28-K40W 64 50 S28-K50W 70 63 S28-K63W 80 2 pole 0.2 S282-K0.2W 28 0.3 S282-K0.3W 28 0.5 S282-K0.5W 28 0.75 S282-K0.75W 28 S282-KW 28.6 S282-K.6W 28 2 S282-K2W 28 3 S282-K3W 28 4 S282-K4W 28 6 S282-K6W 28 B 5 9.2 8 S282-K8W 28 0 S282-K0W 28 3 S282-K3W 28 6 S282-K6W 28 20 S282-K20W 28 25 S282-K25W 30 32 S282-K32W 34 40 S282-K40W 34 50 S282-K50W 62 63 S282-K63W 82 Rated Catalog List Delivery current number price class 3 pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S283-K0.2W $ 94 0.3 S283-K0.3W 94 0.5 S283-K0.5W 94 0.75 S283-K0.75W 94 S283-KW 94.6 S283-K.6W 94 2 S283-K2W 94 3 S283-K3W 94 4 S283-K4W 94 6 S283-K6W 94 B 3 3.9 8 S283-K8W 94 0 S283-K0W 94 3 S283-K3W 94 6 S283-K6W 94 20 S283-K20W 94 25 S283-K25W 96 32 S283-K32W 200 40 S283-K40W 2 50 S283-K50W 246 63 S283-K63W 280 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds 0,000 5000 000 500 00 50 0 5 0.5 0. 0.05 0.0 K AC DC For use with ring tongue terminal connectors 2 3 5 8 02 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB7.

K UL S200 Series 077 VDE 0660 CSA 22.2 No. 235 Cable and Equipment Protection S280UC 500 VDC Supplemental protectors S28UC-K, pole S282UC-K, 2 pole S283UC-K, 3 pole Rated Catalog List Delivery current number price class pole 0.2 S28UC-K0.2 $ 04 0.3 S28UC-K0.3 04 0.5 S28UC-K0.5 04 0.75 S28UC-K0.75 04 S28UC-K 04.6 S28UC-K.6 04 2 S28UC-K2 04 3 S28UC-K3 04 4 S28UC-K4 04 6 S28UC-K6 04 B 0 4.6 8 S28UC-K8 04 0 S28UC-K0 04 6 S28UC-K6 04 20 S28UC-K20 04 25 S28UC-K25 08 32 S28UC-K32 0 40 S28UC-K40 6 50 S28UC-K50 36 63 S28UC-K63 52 2 pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S282UC-K0.2 242 0.3 S282UC-K0.3 242 0.5 S282UC-K0.5 242 0.75 S282UC-K0.75 242 S282UC-K 242.6 S282UC-K.6 242 2 S282UC-K2 242 3 S282UC-K3 242 4 S282UC-K4 242 B 5 9.2 6 S282UC-K6 242 8 S282UC-K8 242 0 S282UC-K0 242 6 S282UC-K6 242 20 S282UC-K20 242 25 S282UC-K25 248 32 S282UC-K32 256 40 S282UC-K40 266 50 S282UC-K50 32 63 S282UC-K63 348 Rated Catalog List Delivery current number price class 3 pole 0.2 S283UC-K0.2 $ 370 0.3 S283UC-K0.3 370 0.5 S283UC-K0.5 370 0.75 S283UC-K0.75 370 S283UC-K 370.6 S283UC-K.6 370 2 S283UC-K2 370 3 S283UC-K3 370 4 S283UC-K4 370 6 S283UC-K6 370 8 S283UC-K8 370 0 S283UC-K0 370 6 S283UC-K6 370 20 S283UC-K20 370 25 S283UC-K25 382 32 S283UC-K32 408 40 S283UC-K40 448 50 S283UC-K50 472 63 S283UC-K63 534 Sugg. order qty B 3 3.9 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) Direct current applications The S280UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown below. seconds UC-K 0,000 5000 000 500 00 50 0 5 0.5 0. 0.05 DC 0.0 2 3 5 0 20 30 multiple of rated current - +2 Maximum voltage between leads 250VDC 500VDC Single Pole S28UC L- L+ LOAD - + Two Pole L- L+ S282UC L- L+ - 3+ - +2 3+ 4-4- LOAD - + LOAD - + Termination points are marked on all UC type MCBs, points one () and four (4) are negative and points two (2) and three (3) are positive. Four pole breakers are also available for voltage reversal applications. +2.2 Discount schedule CB7 Low Voltage Products & Systems

S200P & S280UC 480Y/277 VAC & 500 VDC Supplemental protectors S200 Series Z UL 0,000 5000 000 500 00 50 077 VDE 0660 CSA 22.2 No. 235 Fast trip characteristic S20P-Z, pole S202P-Z, 2 pole S203P-Z, 3 pole Z 480Y/277 VAC 500 VDC Rated Catalog List Delivery current number price class pole Sugg. order qty Wgt. oz. ( pc.) 0.5 S20P-Z0.5 $ 70 S20P-Z 70.6 S20P-Z.6 70 2 S20P-Z2 70 3 S20P-Z3 70 4 S20P-Z4 70 6 S20P-Z6 70 8 S20P-Z8 70 B 0 4.5 0 S20P-Z0 70 6 S20P-Z6 70 20 S20P-Z20 70 25 S20P-Z25 70 32 S20P-Z32 74 40 S20P-Z40 78 50 S20P-Z50 88 63 S20P-Z63 00 2 pole 0.5 S202P-Z0.5 62 S202P-Z 62.6 S202P-Z.6 62 2 S202P-Z2 62 3 S202P-Z3 62 4 S202P-Z4 62 6 S202P-Z6 62 8 S202P-Z8 62 B 5 9.2 0 S202P-Z0 62 6 S202P-Z6 62 20 S202P-Z20 62 25 S202P-Z25 70 32 S202P-Z32 70 40 S202P-Z40 76 50 S202P-Z50 206 63 S202P-Z63 232 3 pole 0.5 S203P-Z0.5 244 S203P-Z 244.6 S203P-Z.6 244 2 S203P-Z2 244 3 S203P-Z3 244 4 S203P-Z4 244 6 S203P-Z6 244 8 S203P-Z8 244 B 3.9 0 S203P-Z0 244 6 S203P-Z6 244 20 S203P-Z20 244 25 S203P-Z25 248 32 S203P-Z32 254 40 S203P-Z40 266 50 S203P-Z50 306 63 S203P-Z63 344 0,000 5000 000 500 00 50 UC-Z Rated Catalog List Delivery current number price class pole 0.5 S28UC-Z0.5 $ 68 S28UC-Z 68.6 S28UC-Z.6 68 2 S28UC-Z2 68 3 S28UC-Z3 68 4 S28UC-Z4 68 6 S28UC-Z6 68 8 S28UC-Z8 68 0 S28UC-Z0 68 B 0 4.6 6 S28UC-Z6 68 20 S28UC-Z20 68 25 S28UC-Z25 70 32 S28UC-Z32 76 40 S28UC-Z40 88 50 S28UC-Z50 26 63 S28UC-Z63 242 2 pole 0.5 S282UC-Z0.5 390 S282UC-Z 390.6 S282UC-Z.6 390 2 S282UC-Z2 390 3 S282UC-Z3 390 4 S282UC-Z4 390 6 S282UC-Z6 390 8 S282UC-Z8 390 0 S282UC-Z0 390 6 S282UC-Z6 390 20 S282UC-Z20 390 25 S282UC-Z25 398 32 S282UC-Z32 40 40 S282UC-Z40 426 50 S282UC-Z50 498 63 S282UC-Z63 558 3 pole Delivery Class Sugg. order qty B 5 9.2 0.5 S283UC-Z0.5 594 S283UC-Z 594.6 S283UC-Z.6 594 2 S283UC-Z2 594 3 S283UC-Z3 594 4 S283UC-Z4 594 6 S283UC-Z6 594 8 S283UC-Z8 594 B 3 3.9 0 S283UC-Z0 594 6 S283UC-Z6 594 20 S283UC-Z20 594 25 S283UC-Z25 603 32 S283UC-Z32 62 40 S283UC-Z40 657 50 S283UC-Z50 756 63 S283UC-Z63 855 A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) 0 5 0 5 seconds 0.5 AC 0. 0.05 DC 0.0 2 3 5 0 20 30 multiple of rated current seconds 0.5 0. 0.05 DC 0.0 2 3 5 0 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB7.3

S200 Series S200U 240 VAC Miniature MCCBs K UL 489 CSA C22.2 - NO. 5 VDE 0660 Cable & equipment protection S20U-K, pole S202U-K, 2 pole S203U-K, 3 pole S204U-K, 4 pole K Rated Catalog List Delivery current number price class pole 0.2 S20U-K0.2 $ 54 0.3 S20U-K0.3 54 0.5 S20U-K0.5 54 0.75 S20U-K0.75 54 S20U-K 54.6 S20U-K.6 54 2 S20U-K2 54 3 S20U-K3 54 4 S20U-K4 54 5 S20U-K5 54 6 S20U-K6 54 8 S20U-K8 54 0 S20U-K0 54 A 0 4.6 3 S20U-K3 54 5 S20U-K5 54 6 S20U-K6 54 20 S20U-K20 54 25 S20U-K25 56 30 S20U-K30 58 32 S20U-K32 58 40 S20U-K40 64 50 S20U-K50 70 60 S20U-K60 80 63 S20U-K63 80 2 pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S202U-K0.2 28 0.3 S202U-K0.3 28 0.5 S202U-K0.5 28 0.75 S202U-K0.75 28 S202U-K 28.6 S202U-K.6 28 2 S202U-K2 28 3 S202U-K3 28 4 S202U-K4 28 5 S202U-K5 28 6 S202U-K6 28 8 S202U-K8 28 A 5 9.2 0 S202U-K0 28 3 S202U-K3 28 5 S202U-K5 28 6 S202U-K6 28 20 S202U-K20 28 25 S202U-K25 30 30 S202U-K30 34 32 S202U-K32 34 40 S202U-K40 34 50 S202U-K50 62 60 S202U-K60 82 63 S202U-K63 82 Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 3 pole 0.2 S203U-K0.2 $ 94 0.3 S203U-K0.3 94 0.5 S203U-K0.5 94 0.75 S203U-K0.75 94 S203U-K 94.6 S203U-K.6 94 2 S203U-K2 94 3 S203U-K3 94 4 S203U-K4 94 5 S203U-K5 94 6 S203U-K6 94 8 S203U-K8 94 0 S203U-K0 94 A 3.9 3 S203U-K3 94 5 S203U-K5 94 6 S203U-K6 94 20 S203U-K20 94 25 S203U-K25 96 30 S203U-K30 200 32 S203U-K32 200 40 S203U-K40 2 50 S203U-K50 246 60 S203U-K60 280 63 S203U-K63 280 4 pole 0.2 S204U-K0.2 265 0.3 S204U-K0.3 265 0.5 S204U-K0.5 265 0.75 S204U-K0.75 265 S204U-K 265.6 S204U-K.6 265 2 S204U-K2 265 3 S204U-K3 265 4 S204U-K4 265 5 S204U-K5 265 6 S204U-K6 265 8 S204U-K8 265 0 S204U-K0 265 B 8.0 3 S204U-K3 265 5 S204U-K5 265 6 S204U-K6 265 20 S204U-K20 265 25 S204U-K25 275 30 S204U-K30 285 32 S204U-K32 285 40 S204U-K40 3 50 S204U-K50 343 60 S204U-K60 392 63 S204U-K63 392 seconds 0,000 5000 000 500 00 50 0 5 0.5 0. 0.05 AC DC UL489 listed as branch circuit protective device Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 0.0 2 3 5 8 02 20 30 multiple of rated current. Discount schedule CB2 Low Voltage Products & Systems

S200U 240 VAC Miniature MCCBs S200 Series Z UL 489 CSA C22.2 - NO. 5 VDE 0660 Cable & equipment protection S20U-Z, pole S202U-Z, 2 pole S203U-Z, 3 pole Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty pole 0.5 S20U-Z0.5 70 0.75 S20U-Z0.75 70 S20U-Z 70.6 S20U-Z.6 70 2 S20U-Z2 70 3 S20U-Z3 70 4 S20U-Z4 70 5 S20U-Z5 70 6 S20U-Z6 70 8 S20U-Z8 70 0 S20U-Z0 70 A 0 4.6 5 S20U-Z5 70 6 S20U-Z6 70 20 S20U-Z20 70 25 S20U-Z25 70 30 S20U-Z30 74 32 S20U-Z32 74 40 S20U-Z40 78 50 S20U-Z50 88 60 S20U-Z60 00 63 S20U-Z63 00 2 pole 0.5 S202U-Z0.5 62 0.75 S202U-Z0.75 62 S202U-Z 62.6 S202U-Z.6 62 2 S202U-Z2 62 3 S202U-Z3 62 4 S202U-Z4 62 5 S202U-Z5 62 6 S202U-Z6 62 8 S202U-Z8 62 0 S202U-Z0 62 A 5 9.2 5 S202U-Z5 62 6 S202U-Z6 62 20 S202U-Z20 62 25 S202U-Z25 70 30 S202U-Z30 70 32 S202U-Z32 70 40 S202U-Z40 76 50 S202U-Z50 206 60 S202U-Z60 232 63 S202U-Z63 232 Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 3 pole 0.5 S203U-Z0.5 244 0.75 S203U-Z0.75 244 S203U-Z 244.6 S203U-Z.6 244 2 S203U-Z2 244 3 S203U-Z3 244 4 S203U-Z4 244 5 S203U-Z5 244 6 S203U-Z6 244 8 S203U-Z8 244 0 S203U-Z0 244 A 3.9 5 S203U-Z5 244 6 S203U-Z6 244 20 S203U-Z20 244 25 S203U-Z25 248 30 S203U-Z30 254 32 S203U-Z32 254 40 S203U-Z40 266 50 S203U-Z50 306 60 S203U-Z60 344 63 S203U-Z63 344 4 pole 0.5 S204U-Z0.5 343 0.75 S204U-Z0.75 343 S204U-Z 343.6 S204U-Z.6 343 2 S204U-Z2 343 3 S204U-Z3 343 4 S204U-Z4 343 5 S204U-Z5 343 6 S204U-Z6 343 8 S204U-Z8 343 0 S204U-Z0 343 B 8.0 5 S204U-Z5 343 6 S204U-Z6 343 20 S204U-Z20 343 25 S204U-Z25 343 30 S204U-Z30 363 32 S204U-Z32 363 40 S204U-Z40 382 50 S204U-Z50 43 60 S204U-Z60 490 63 S204U-Z63 490 Delivery Class 0,000 5000 000 500 00 50 0 5 S204U-Z, 4 pole Z UL489 listed as branch circuit protective device A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 0 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB2.5

S200 Series S200UP 480Y/277 VAC Miniature MCCBs K UL 489 CSA C22.2 - NO. 5 VDE 0660 Cable & equipment protection S20UP-K, pole S202UP-K, 2 pole S203UP-K, 3 pole Rated Catalog List Delivery current number price class pole 0.2 S20UP-K0.2 $ 90 0.3 S20UP-K0.3 90 0.5 S20UP-K0.5 90 0.75 S20UP-K0.75 90 S20UP-K 90.6 S20UP-K.6 90 2 S20UP-K2 90 3 S20UP-K3 90 4 S20UP-K4 90 5 S20UP-K5 90 6 S20UP-K6 90 8 S20UP-K8 90 A 0 4.6 0 S20UP-K0 90 3 S20UP-K3 90 5 S20UP-K5 90 6 S20UP-K6 90 20 S20UP-K20 90 25 S20UP-K25 90 2 pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S202UP-K0.2 20 0.3 S202UP-K0.3 20 0.5 S202UP-K0.5 20 0.75 S202UP-K0.75 20 S202UP-K 20.6 S202UP-K.6 20 2 S202UP-K2 20 3 S202UP-K3 20 4 S202UP-K4 20 5 S202UP-K5 20 6 S202UP-K6 20 A 5 9.2 8 S202UP-K8 20 0 S202UP-K0 20 3 S202UP-K3 20 5 S202UP-K5 20 6 S202UP-K6 20 20 S202UP-K20 20 25 S202UP-K25 20 Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 3 pole 0.2 S203UP-K0.2 $ 320 0.3 S203UP-K0.3 320 0.5 S203UP-K0.5 320 0.75 S203UP-K0.75 320 S203UP-K 320.6 S203UP-K.6 320 2 S203UP-K2 320 3 S203UP-K3 320 4 S203UP-K4 320 5 S203UP-K5 320 6 S203UP-K6 320 A 3.9 8 S203UP-K8 320 0 S203UP-K0 320 3 S203UP-K3 320 5 S203UP-K5 320 6 S203UP-K6 320 20 S203UP-K20 320 25 S203UP-K25 320 4 pole 0.2 S204UP-K0.2 440 0.3 S204UP-K0.3 440 0.5 S204UP-K0.5 440 0.75 S204UP-K0.75 440 S204UP-K 440.6 S204UP-K.6 440 2 S204UP-K2 440 3 S204UP-K3 440 4 S204UP-K4 440 5 S204UP-K5 440 6 S204UP-K6 440 B 8.0 8 S204UP-K8 440 0 S204UP-K0 440 3 S204UP-K3 440 5 S204UP-K5 440 6 S204UP-K6 440 20 S204UP-K20 440 25 S204UP-K25 440 Delivery Class 0,000 5000 000 500 S204UP-K, 4 pole K UL489 listed as branch circuit protective device A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 00 50 0 5 seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 8 02 20 30 multiple of rated current.6 Discount schedule CB7 Low Voltage Products & Systems

S200UP 480Y/277 VAC Miniature MCCBs S200 Series Z UL 489 CSA C22.2 - NO. 5 VDE 0660 Cable & equipment protection S20UP-Z, pole S202UP-Z, 2 pole Rated Catalog List Delivery current number price class pole 0.5 S20UP-Z0.5 5 0.75 S20UP-Z0.75 5 S20UP-Z 5.6 S20UP-Z.6 5 2 S20UP-Z2 5 3 S20UP-Z3 5 4 S20UP-Z4 5 5 S20UP-Z5 5 6 S20UP-Z6 5 8 S20UP-Z8 5 A 0 4.6 0 S20UP-Z0 5 5 S20UP-Z5 5 6 S20UP-Z6 5 20 S20UP-Z20 5 25 S20UP-Z25 5 2 pole Sugg. order qty Wgt. oz. ( pc.) 0.5 S202UP-Z0.5 270 0.75 S202UP-Z0.75 270 S202UP-Z 270.6 S202UP-Z.6 270 2 S202UP-Z2 270 3 S202UP-Z3 270 4 S202UP-Z4 270 5 S202UP-Z5 270 6 S202UP-Z6 270 A 5 9.2 8 S202UP-Z8 270 0 S202UP-Z0 270 5 S202UP-Z5 270 6 S202UP-Z6 270 20 S202UP-Z20 270 25 S202UP-Z25 270 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 3 pole 0.5 S203UP-Z0.5 400 0.75 S203UP-Z0.75 400 S203UP-Z 400.6 S203UP-Z.6 400 2 S203UP-Z2 400 3 S203UP-Z3 400 4 S203UP-Z4 400 5 S203UP-Z5 400 6 S203UP-Z6 400 A 3.9 8 S203UP-Z8 400 0 S203UP-Z0 400 5 S203UP-Z5 400 6 S203UP-Z6 400 20 S203UP-Z20 400 25 S203UP-Z25 400 4 pole 0.5 S204UP-Z0.5 564 0.75 S204UP-Z0.75 564 S204UP-Z 564.6 S204UP-Z.6 564 2 S204UP-Z2 564 3 S204UP-Z3 564 4 S204UP-Z4 564 5 S204UP-Z5 564 6 S204UP-Z6 564 B 8.0 8 S204UP-Z8 564 0 S204UP-Z0 564 5 S204UP-Z5 564 6 S204UP-Z6 564 20 S204UP-Z20 564 25 S204UP-Z25 564 S203UP-Z, 3 pole Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 0,000 5000 000 500 S204UP-Z, 4 pole Z UL489 listed as branch circuit protective device 00 50 0 5 seconds 0.5 0. 0.05 0.0 AC DC 2 3 5 0 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB7.7

S200 Series S290 480Y/277 VAC C VDE 0660 Cable and equipment protection S29-C80 480 VAC Rated Catalog List Delivery current number price class pole Sugg. order qty Wgt. oz. ( pc.) 80 S29-C80 $ 38 00 S29-C00 4 B 6 9.2 25 S29-C25 92 2 pole 80 S292-C80 340 00 S292-C00 364 B 3 8.4 25 S292-C25 568 3 pole 80 S293-C80 536 00 S293-C00 548 B 2 27.6 25 S293-C25 732 4 pole 80 S294-C80 740 00 S294-C00 756 B 36.8 25 S294-C25 948 S290-H Auxiliary contact S290-H 72 B.75 Bell alarm S290-S 2 B.75 Shunt trip S290-A 4 B 6.2 For field mounting, left side, 0V 45VAC S290-A2 4 B 6.2 For field mounting, left side, 24 48VDC Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 0,000 5000 C 000 500 00 50 0 5 seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 0 8 20 30 multiple of rated current.8 Discount schedule CB2 Low Voltage Products & Systems

Accessories Busbars S200 Series For use on: Amp Number Busbar End cap Catalog List Delivery Suggested rating of length catalog number price class order qty. poles (mm) number quantity S200 & 63 60 988 PS-END0 PS/60 $ 36 A S200P 80 60 988 PS-END0 PS/60/6 46 Weight (ozs) 9 S200U & 6 08 PS/6/6BP 30.4 S200UP 80 2 26 PS/2/6BP 60 B 2.9 23 8 324 PS/8/6BP 90 4.3 For use on: Amp Number Busbar End cap Catalog List Delivery Suggested rating of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & 63 58 035 PS-ENDSP PS2/58SP $ 22 S200P 80 58 035 PS-ENDSP PS2/58/6SP 52 A 8 S200U & 6 08 PS2/6/6BP 40.8 S200UP 80 2 26 PS2/2/6BP 80 B 3.7 23 8 324 PS2/8/6BP 20 5.5 For use on: Amp Number Busbar End cap Catalog List Delivery Suggested rating of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & 63 60 065 PS-ENDSP PS3/60SP $ 30 2 A S200P 80 60 065 PS-ENDSP PS3/60/6SP 76 20 S200U & 6 08 PS3/6/6BP 44 2 S200UP 80 2 26 PS3/2/6BP 88 B 4 23 8 324 PS3/8/6BP 32 6 For use on: S200 & S200P Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. (ozs) poles (mm) number quantity 80 60 056 PS-ENDSP PS4/60/6SP $ 236 B 22 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time NOTE All bus bars may be center fed in order to double the ampacity rating NOTE BUS BARS MAY BE USED ON LINE OR LOAD SIDE OF MCBS UL Approved for use on UL077 miniature circuit breakers. UL File #E7626 2 UL approved for use on UL 489 miniature circuit breakers. UL File # E2505 3 UL 489 bus bars may not be cut. Low Voltage Products & Systems Discount schedule CB8.9

S200 Series Accessories Busbars Phase with auxiliary Amp Number Busbar End cap Catalog List Delivery Suggested For Weight rating of length catalog number price class order qty. use on: (ozs) poles (mm) number quantity S200 & 63 38 044 PS-END0 PS/38H $ 50 B 7.4 S200P 80 38 044 PS-END0 PS/38/6H 56 0. L L L L... 2 Phase with auxillary For use on: Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & S200P 80 48 065 PS-ENDSP PS2/48/6SP $ 74 B 23.3 L L2 L L2 L L2 L L2... 3 Phase with auxillary For use on: Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & S200P 80 39 980 PS-ENDSP PS3/39/6SP $ 58 B 22.6 L L2 L3 L L2 L3 L L2 L3... For use on: S200 & S200P Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of length catalog number price class order qty. (ozs) poles (mm) number quantity 80 58 048 PS-ENDSP PS4/58/6NSP $ 238 B 30.8 Insulated busbar assembly contains 4 separate circuits for use with +N or 2 pole MCBs. Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time NOTE All bus bars may be center fed in order to double the ampacity rating NOTE BUS BARS MAY BE USED ON LINE OR LOAD SIDE OF MCBS.20 Discount schedule CB8 Low Voltage Products & Systems

Accessories S200 Series Auxiliary contacts For field mounting: right side Form C NO / NC Electrical For Catalog List Delivery Suggested Wgt. oz. accessories use on: number price class order quantities ( pc.) S200 & S200P S200U S200UP S2C-H6R S2C-H6RU $ 36 A.4 S2C-H6R The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. Wire size: 8 AWG to 6 AWG. S2C-S/H6R Bell alarm S200 & S200P S2C-S/H6R For field mounting, right side 48 A.4 S200U S200UP S2C-S6RU The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. The contact is rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. * Combination bell alarm/auxiliary contact S2C-A_ Shunt trip S200 & S2C-A For field mounting, right side S200P S2C-A2 A: 2-60 VAC (2-60VDC) 38 A 5.2 A2: 0-45 VAC (0-250 VDC) S200U & S2C-AU S200UP S2C-A2U For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Shunt trips are available for on control system voltage (2-45 VAC/VDC). Undervoltage release For field mounting, right side 2 VDC S2C-UA2 24 VAC S2C-UA24 48 VAC S200 & S2C-UA48 0 VAC S200P S2C-UA0 220 VAC S2C-UA230 45 VAC S2C-UA400 26 A 5.2 When control voltage drops below approximately 50% of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory. S2C-UA_ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Low Voltage Products & Systems Discount schedule CB8 9/6/07 Rev..2

S200 Series Accessories S200 S500-ME2 MB-CL MB-3PD SA Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) Front mounting kit For 2 poles S500-ME $ 60 2. For 2 5 poles S500-ME2 70 A 2.9 For 2 0 poles S500-ME3 80 3.6 Optional rear terminals S500-K 6.5 Includes flange, mounting rail and hardware. Front mounting clip For 4 poles MB-CL 35 A 2 Simple mounting clip for up to four module mounting. Front mounting bracket For 3 poles MB-3PD 35 A 2.5 For flush mounting of three pole MCBs: includes hardware. Locking device Adaptor only SA 9 A 0 0.7 Padlock only w/ 2 keys SA2 9 0. Allows breaker to be locked in ON or OFF position. Labeling accessory sheet = 40 blank labels BS 74 sheet = 40 numbered labels BS/40 74 Adhesive labels mount on front face of components. Enclosure, IP40 A For 2 modules 2402 32 2.0 For 4 modules 2404 45 B 2.8 For 6 modules 2406 56 3.4 For 8 modules 2408 66 4. For additional protection against accidental contact. Includes integrated mounting rail. SA2 Enclosure, IP55 For 4 modules 2644 84 8. For 6 modules 2646 98 A 0.8 For 0 modules 2650 26 20.4 For 20 modules 2652 20 4.0 Molded plastic complete with mounting rail and knock-outs for cable entries. 2404 Blanking plates Single pole (set of 0) BP-P 6 A Twelve pole (snap-off, set of ) BP-2P 7 Handle mechanism For use with 2, 3 and 4 pole S2 MCBs and disconnect switch handles with 5mm shaft. S2C-DH 76 A 9.2 DIN rail Universal mounting SMR-39 2 A 8 35mm DIN rails are available in 39-inch strips ( meter). S2C-DH Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time SMR-39.22 Discount schedule CB8 Low Voltage Products & Systems Discount schedule H6 Handles & shafts

Accessories S200 S200 Series SZ-BSK SZ-ESK2 SZ-AST55_ Busbar accessories Busbar end caps Catalog List Delivery Suggested Weight Description number price class order qty. ounce qty. (2 pc.) Busbar tooth covers (shrouds unused portion of busbar) 2 & 3 phase PS-ENDSP 4 phase PS-ENDSP $ 2 A 0 SZ-BSK 4 A 0 Busbar mounted terminal block, pole, for use on all busbars. SZ-ESK2 0 A.0 Wire size: AWG to 2 AWG Electrical accessories Posidrive tools Item Catalog List Delivery Suggested Wgt. oz. number price class order quantities ( pc.) Screwdriver, # SD-PZ $ 40 A 4 Screwdriver, #2 SD-PZ2 40 A 4 Bit, # BIT-PZ 4 A 4 Bit, #2 BIT-PZ2 4 A 4 Connection terminals Cross section For Catalog List Delivery Suggested Wgt. oz. AWG/mm 2 use on: number price class order quantities ( pc.) /0 (50mm 2 ) Straight SZ-AST55I $ 5 0 0.5 S200 & S200P B /0 (50mm 2 ) 90 SZ-AST50I 5 0 0.5 /0 (50mm 2 ) Straight SZ-AST55U 5 0 0.5 S200U & S200UP B /0 (50mm 2 ) 90 SZ-AST50U 5 0 0.5 Ring tongue accessories Catalog List Delivery Suggested Weight Description For use on number price class order qty. ounce qty. (2 pc.) Ring tongue terminal S200 & S200P S200U & S200UP SZ-AST55UPRT $ 5 A 0 0.5 Plug S2C-P N/C A 0 SZ-AST50_ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Low Voltage Products & Systems Discount schedule CB8.23 9/6/07 Rev.

S200 Series Technical data Mounting and operating instructions Mounting MCB Removing MCB Mounting Universal mounting position using snap-on mounting to standard 35x7.5mm DIN rail. Miniature circuit breakers (MCBs) can also be mount ed to front of door using a panel cut-out with breaker handle pro trud ing through panel opening for external operation. Special front mount ing kit page 23. Connection Terminals are suitable for solid or flexible conductors from 8 to 4 AWG (0.75 to 25mm 2 ) with no busbar connected. When max i mum busbar size of 36 mm 2 is used, maximum cable is 6 AWG (6 mm 2 ). Maximum tightening torque of 7.5 in-lb (2 Nm) for line/load terminals and 4.5 in-lb (0.5Nm) for ac ces so ry device terminals. Operation MCBs are switched on by moving the handle to the upper po si tion. Stamped onto the handle switch, a I is visible confirming that the breaker is closed. The MCBs are trip-free, if the handle is being forced to the ON position, the breaker will still trip under fault conditions. The O marking indicates that the breaker is in the OFF position. The MCB is now open and the load is disconnected from line power. When a breaker has tripped, the MCB handle should first be set to the full OFF position to make certain the trip mechanism has been reset. Once the fault has been determined and cleared the MCB can again be switched ON. Maintenance ABB miniature circuit breakers require no special maintenance; only normal electrical system maintenance pro ce dures are required. Possible mounting arrangements of MCB accessories Legend S 200 +S/H+S/H (H)+S/H (H) Auxiliary contact Bell alarm/auxiliary contact H S/H +H+H+H Bell alarm/auxiliary contact used as auxiliary contact S/H (H) Shunt trip ST Undervoltage release UR +ST+H+H+H +ST+S/H+S/H (H)+S/H (H) +UR+H+H+H +UR+S/H+S/H (H)+S/H (H).24 Low Voltage Products & Systems

Technical data Busbars & connectors Connection methods S200 Series Top and bottom dual function terminals provided in open position for connection to busbars or cable. Terminals allow for connection of cable 8-4 AWG [top row] and 8-8 AWG [bottom row]. Two slots per terminal offer the ability to connect, independently, two conductors. This may be cables or bus bar. Top and bottom terminals may be bussed together with single phase or multi-phase busbars as shown. Both line and load side terminals can be bus bar connected. Easy removal of devices from an assembly when using bus bar in the bottom, load side terminals. Conductors may only be inserted into open terminals, preventing mis-wiring and potential problems. Low Voltage Products & Systems.25

S200 Series Technical data Item S200-B S200-C, -D S200-K S200P-K Approvals: UL 077 077 077 077 CSA C22.2 No.235 C22.2 No. 235 C22.2 No. 235 VDE 064, 0660 0660 0660 0660 IEC 898, 947 898, 947 898, 947 898, 947 No. of poles:,2,3,4 +N,3+N,2,3, +N,3+N,2,3,4, +N,3+N,2,3,4,+N,3+N Tripping characteristic: B C,D K K Rated currents: 6 to 63A 0.5 to 63A 0.5 to 63A 0.2 to 63A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 20VAC 0kA 0kA 0kA 0kA 240VAC 6kA 0kA 6kA 0kA 6kA 0kA 0kA 0kA 277VAC 6kA 6kA 6kA 0kA 277/480 VAC 6kA 6kA 6kA 0kA 60VDC 0kA 0kA 0kA 0kA 0kA 0kA 25VDC 0kA 0kA 0kA Frequency: 50/60Hz (See below) 50/60Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 240/45VAC 240/45VAC 240/45VAC 240/45VAC 60VDC 60VDC 60VDC 60VDC IEC multi-pole 45VAC 45VAC 45VAC 45VAC 0VDC 0VDC 0VDC 0VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN rail 35mm DIN rail Main and shunt trip terminals: Wire size 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-8 [bottom] 8-8 [bottom] 8-8 [bottom] 8-8 [bottom] Torque 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -25 C to +70 C -25 C to +70 C -25 C to +70 C -25 C to +70 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz @ 0.8 ~ I n @ 0.8 ~ I n @ 0.8 ~ I n @ 0.8 ~ I n Disconnecting neutral rating: 6kA switching 6kA switching 6kA switching Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz DC Approx. factor..2.5.5 Thermal tripping is independent of frequency..26 Low Voltage Products & Systems

Technical data S200 Series Item S280UC-K S200P-Z S280UC-Z S290-C Approvals: UL 077 077 077 CSA VDE 0660 0660 0660 0660 IEC 898,947 898, 947 898, 947 898 No. of poles:,2,3,2,3,4,2,3,2,3,4 Tripping characteristic: K Z Z C Rated currents: 0.2 to 63A 0.5 to 63A 0.5 to 63A 80 to 25A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 20VAC 0kA 0kA 0kA 240VAC 0kA 0kA 0kA 0kA 0kA 0kA 277VAC 0kA 0kA 0kA 277/480 VAC 4.5kA for 0.2-40A 0kA 4.5kA for 0.2-40A 5kA for 50-63A 5kA for 50-63A 60VDC 0kA 0kA 0kA 0kA 25VDC 0kA 0kA 0kA 0kA 250VDC 4.5kA 4.5kA 4.5kA 4.5kA 500VDC 4.5kA 4.5kA Frequency: 50/60Hz (see below) 50/60 Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 240/45VAC 240/45VAC 240/45VAC 230/440VAC 220VDC 60VDC 220VDC 60VDC IEC multi-pole 45VAC 45VAC 45VAC 440VAC 440VDC 0VDC 440VDC 0VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 70mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN-rail 35mm DIN-rail Main and shunt trip terminals: Wire size 0.2-40A 8-4 AWG 8-4 AWG [top] 0.5-40A 8-4 AWG 80-25A -/0 AWG 50A & above 8-2 AWG 8-8 AWG [bottom] 8-2 AWG Torque 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -25 C to +55 C -25 C to +70 C -25 C to +55 C -5 C to +45 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 60m/s 2, at 0 50 Hz @ 0.8 ~ I n @ 0.8 ~ I n @ 0.8 ~ I n Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz DC Approx. factor..2.5.5 Thermal tripping is independent of frequency. Low Voltage Products & Systems.27

S200 Series Technical data Item S200U-K S200U-Z S200UP-K S200UP-Z Approvals: UL 489 489 489 489 CSA C22.2 No.5 C22.2 No.5 C22.2 No.5 C22.2 No.5 VDE 0660 0660 0660 0660 IEC 898,947 898, 947 898, 947 898 No. of poles:,2,3,4,2,3,4,2,3,4,2,3,4 Tripping characteristic: K Z K Z Rated currents: 0.2 to 63A 0.2 to 63A 0.2 to 25A 0.2 to 25A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & interrupting capacity 20VAC 0kA 0kA 0kA 0kA 240VAC 0kA 0kA 0kA 0kA 277VAC 0kA 0kA 480/277 VAC 0kA 0kA Frequency: 50/60Hz (see below) 50/60 Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 240/45VAC 240/45VAC 240/45VAC 240/45VAC 220VDC 60VDC 220VDC 220VDC IEC multi-pole 45VAC 45VAC 45VAC 45VAC 440VDC 0VDC 440VDC 440VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN-rail 35mm DIN-rail Main and shunt trip terminals: Wire size 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-8 AWG [bottom] 8-8 AWG [bottom] 8-8 AWG [bottom] 8-8 AWG [bottom] Torque 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -25 C to +70 C -25 C to +70 C -25 C to +70 C -25 C to +70 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz @ 0.8 ~ I n @ 0.8 ~ I n @ 0.8 ~ I n @ 0.8 ~ I n Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz DC Approx. factor..2.5.5 Thermal tripping is independent of frequency..28 Low Voltage Products & Systems

Technical data Wire size comparison S200 Series Comparison of IEC and AWG wire sizes mm AWG (mm ) Amps / UL Amps / IEC.0 8 6 (.3) 0.5 2 (2.) 5 2.5 20 2 (3.3) 20 4 25 0 (5.3) 30 6 32 8 (8.4) 50 0 50 6 (3.3) 65 6 65 4 (2.2) 85 25 85 3 (26.7) 00 2 (33.6) 5 35 5 Ampacities for AWG wire are based on copper cable rated 75 C, except for 6AWG which is based on 60 C wire. Taken from UL508 Table 52.2. Consult applicable standards for futher detail and information. Low Voltage Products & Systems.29

S200 Series Approximate dimensions S200, S200P, S200U, S200UP 00.00 00.00 Inches [Millimeters] S200 & S200P S200U S200UP S290 Accessories mount to right side of MCB only.77 45.97 50.03 26 2.3 54.06 27 0.69 7.5 0.35 9 0.35 9 3.9 8 -A, -A2 Shunt trip -H Auxiliary switch -S Bell alarm.30 Low Voltage Products & Systems

00.00 00.00 Inches [Millimeters] Approximate dimensions Accessories S200 Series Accessories mm S 2C-A... S 2C-UA... S 2C-H... S 2C-S... S 2C-S/H... 7.5 69 8.8 69 85 45 85 45 6.8 6.8 44 44 MB-CL Front mounting clip mm.77 45 D C.L. 2.26 57.5.77 45 C.L. MB-3PD Front mounting bracket 0.69 7.5.38 35 2.07 52.5 3.25 in 2.2 ( 3P ).43 ( 2P ).87 C L C L BREAKER CUT OUT 0.74 ( P ) S2C-DH Handle mechanism 0.63 6 CL BKT. MT. HOLES 0.25 DIA. TYP 2 CL 2.07 52.5.38 35 0.83 2 3.54 90.77 45 3.26 82.5 4.36 0.4 0.27 6.9 Low Voltage Products & Systems.3

S200 Series Approximate dimensions Accessories 00.00 00.00 Inches [Millimeters] 2402-2408 2644 2650 4.92 25 4.3 05 4.92 25 4.92 25 4.3 05 230 9.06 7.09 80 7.09 80 2646 2652 4.92 25 4.3 05 6.30 60 6.09 55 5.32 35 9.84 250 7.09 80 2.60 320.32 Low Voltage Products & Systems

Cross-reference S200 Series Older Suggested Physical Electrical version replacement comparison comparison series S260-B S200-B Same pole spacing Same trip char ac ter is tic S260-C S200-C Same pole spacing Same trip char ac ter is tic S260-D S200-D Same pole spacing Same trip char ac ter is tic S270-K S200-K Same pole spacing Same trip char ac ter is tic S280-K S200P-K Same pole spacing Same trip char ac ter is tic S280-Z S200P-Z Same pole spacing Same trip char ac ter is tic S280U-K S200U-K Same pole spacing Same trip char ac ter is tic S280UX-K S200U-K Smaller pole spacing Same trip char ac ter is tic Many older styles of ABB miniature circuit breakers have been replaced by new and improved versions. Many of these newer styles can be directly interchanged, both electrically and physically, with the older version. There are also many international styles of ABB circuit breakers which are not normal stock items and may be interchanged with stocked ABB versions. Low Voltage Products & Systems.33

S200 Series Notes.34 Low Voltage Products & Systems

Miniature Circuit Breakers compact S500 Series S500 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding safety, reliability and switching capacities. The S500 heavy-duty circuit breaker fulfills these requirements by virtue of its technical features. It is equipped with a thermal and/or electromagnetic release to protect circuits, motors, switchgear and systems from the effects of overload and short-circuit currents. For the worldwide market, the S500 breakers carry UL, CSA, IEC, CE and many other agency approvals. Features High breaking capacity Energy-limiting Current-limiting Extremely fast breaking time Optimal selectivity Various versions for special applications Compact dimensions, DIN cap size Easy and quick to install Easy to connect; finger safe terminals Wide range of accessories UL 077 recognized 600VAC and 500VDC versions UL File # E67556 Low Voltage Products & Systems.35

S500 Series S500 600Y/277 VAC B UL 077 CSA C22.2 VDE 064 IEC 947-2 C VDE UL 077 CSA C22.2 064 IEC 947-2 0,000 5000 S50-C6 S502-C6 S503-C0 B Rated Catalog List Delivery Weight current number price class (oz.) pc pole 6 S50-B6 $ 68 0 S50-B0 68 3 S50-B3 68 6 S50-B6 68 20 S50-B20 68 25 S50-B25 68 B 8.90 32 S50-B32 68 40 S50-B40 68 50 S50-B50 86 63 S50-B63 202 2 pole 3 pole 6 S502-B6 328 0 S502-B0 328 3 S502-B3 328 6 S502-B6 328 20 S502-B20 328 25 S502-B25 328 32 S502-B32 328 40 S502-B40 328 50 S502-B50 362 63 S502-B63 392 6 S503-B6 478 0 S503-B0 478 3 S503-B3 478 6 S503-B6 478 20 S503-B20 478 25 S503-B25 478 32 S503-B32 478 40 S503-B40 478 50 S503-B50 526 63 S503-B63 574 B 7.85 B 25.36 Rated Catalog List Delivery Weight current number price class (oz.) pc pole 6 S50-C6 $ 68 0 S50-C0 68 3 S50-C3 68 6 S50-C6 68 20 S50-C20 68 25 S50-C25 68 B 8.90 32 S50-C32 68 40 S50-C40 68 50 S50-C50 84 63 S50-C63 202 2 pole 6 S502-C6 328 0 S502-C0 328 3 S502-C3 328 6 S502-C6 328 20 S502-C20 328 25 S502-C25 328 32 S502-C32 328 40 S502-C40 328 50 S502-C50 362 63 S502-C63 392 3 pole 6 S503-C6 478 0 S503-C0 478 3 S503-C3 478 6 S503-C6 478 20 S503-C20 478 25 S503-C25 478 32 S503-C32 478 40 S503-C40 478 50 S503-C50 526 63 S503-C63 574 B 7.85 B 25.36 seconds seconds 000 500 00 50 0 5 0.5 AC 0. 0.05 DC 0.0 2 3 5 7 0 20 30 multiple of rated current C 0,000 5000 000 500 00 50 0 5 0.5 AC 0. 0.05 DC 0.0 2 3 5 0 8 20 30 multiple of rated current D VDE Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) pole 3 S50-D3 $ 90 6 S50-D6 90 20 S50-D20 90 25 S50-D25 90 32 S50-D32 90 B 8.90 40 S50-D40 90 50 S50-D50 20 63 S50-D63 226 2 pole 3 pole UL 077 CSA C22.2 064 IEC 947-3 S502-D3 372 6 S502-D6 372 20 S502-D20 372 25 S502-D25 372 32 S502-D32 372 40 S502-D40 372 50 S502-D50 408 63 S502-D63 442 3 S503-D3 544 6 S503-D6 544 20 S503-D20 544 25 S503-D25 544 32 S503-D32 544 40 S503-D40 544 50 S503-D50 600 63 S503-D63 646 B 7.85 B 25.36 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds 0,000 5000 000 500 00 50 0 5 0.5 0. 0.05 0.0 D AC DC 2 3 5 0 20 30 multiple of rated current.36 Discount schedule CB0 Low Voltage Products & Systems

S500 600Y/277 VAC S500 Series seconds S50-D20 S502-D3 S503-K6 K 0,000 5000 000 500 00 50 0 5 0.5 AC 0. 0.05 DC 0.0 2 3 5 8 02 20 30 multiple of rated current K UL 077 CSA C22.2 VDE 064 IEC-898 Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) pole 0. 0.5 S50-K0.5 $ 82 0. 0.2 S50-K0.2 82 0.2 0.3 S50-K0.3 82 0.28 0.42 S50-K0.42 82 0.38 0.58 S50-K0.58 82 0.53 0.8 S50-K0.8 82 0.73. S50-K. 82.5 S50-K.5 82.4 2. S50-K2. 82 2 3 S50-K3 82 2.8 4.2 S50-K4.2 82 B 8.90 3.8 5.8 S50-K5.8 82 5.3 8 S50-K8 82 7.3 S50-K 82 0 5 S50-K5 82 20 S50-K20 82 8 26 S50-K26 82 23 32 S50-K32 202 29 37 S50-K37 202 34 4 S50-K4 226 38 45 S50-K45 226 2 pole 0. 0.5 S502-K0.5 356 0. 0.2 S502-K0.2 356 0.2 0.3 S502-K0.3 356 0.28 0.42 S502-K0.42 356 0.38 0.58 S502-K0.58 356 0.53 0.8 S502-K0.8 356 0.73. S502-K. 356.5 S502-K.5 356.4 2. S502-K2. 356 2 3 S502-K3 356 B 7.85 2.8 4.2 S502-K4.2 356 3.8 5.8 S502-K5.8 356 5.3 8 S502-K8 356 7.3 S502-K 356 0 5 S502-K5 356 20 S502-K20 356 8 26 S502-K26 356 23 32 S502-K32 392 29 37 S502-K37 392 34 4 S502-K4 442 38 45 S502-K45 442 3 pole 0. 0.5 S503-K0.5 58 0. 0.2 S503-K0.2 58 0.2 0.3 S503-K0.3 58 0.28 0.42 S503-K0.42 58 0.38 0.58 S503-K0.58 58 0.53 0.8 S503-K0.8 58 0.73. S503-K. 58.5 S503-K.5 58.4 2. S503-K2. 58 2 3 S503-K3 58 B 25.36 2.8 4.2 S503-K4.2 58 3.8 5.8 S503-K5.8 58 5.3 8 S503-K8 58 7.3 S503-K 58 0 5 S503-K5 58 20 S503-K20 58 8 26 S503-K26 58 23 32 S503-K32 574 29 37 S503-K37 574 34 4 S503-K4 644 38 45 S503-K45 828 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Low Voltage Products & Systems Discount schedule CB0.37

S500 Series S50UC-B40 S502UC-B6 S500UC 600Y/277 VAC 600 VDC B Rated Catalog List Delivery Weight current number price class (oz.) pc pole 6 S50UC-B6 $ 226 0 S50UC-B0 226 3 S50UC-B3 226 6 S50UC-B6 226 20 S50UC-B20 226 25 S50UC-B25 226 C 8.90 32 S50UC-B32 226 40 S50UC-B40 226 50 S50UC-B50 258 63 S50UC-B63 292 2 pole UL 077 CSA C22.2 VDE 0660 6 S502UC-B6 442 0 S502UC-B0 442 3 S502UC-B3 442 6 S502UC-B6 442 20 S502UC-B20 442 25 S502UC-B25 442 32 S502UC-B32 442 40 S502UC-B40 442 50 S502UC-B50 502 63 S502UC-B63 568 C 7.85 Rated Catalog List Delivery Weight current number price class (oz.) pc 3 pole 6 S503UC-B6 $ 646 0 S503UC-B0 646 3 S503UC-B3 646 6 S503UC-B6 646 20 S503UC-B20 646 25 S503UC-B25 646 C 25.36 32 S503UC-B32 646 40 S503UC-B40 646 50 S503UC-B50 734 63 S503UC-B63 832 4 pole 6 S504UC-B6 908 0 S504UC-B0 908 3 S504UC-B3 908 6 S504UC-B6 908 20 S504UC-B20 908 C 35.75 25 S504UC-B25 908 32 S504UC-B32 908 40 S504UC-B40 908 50 S504UC-B50 030 63 S504UC-B63 64 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time S503UC-B50 0,000 5000 B 000 500 00 50 0 5 seconds 0.5 0. 0.05 AC DC 0.0 2 3 5 7 0 20 30 multiple of rated current.38 Discount schedule CB0 Low Voltage Products & Systems

S500 UC 600Y/277 VAC 600 VDC S500 Series K VDE UL 077 CSA C22.2 0660 S50UC-K0.5 S502UC-K0.5 S503UC-K0.5 Rated Catalog List Delivery Weight current number price class (oz.) pc pole 0. 0.5 S50UC-K0.5 $ 250 0. 0.2 S50UC-K0.2 250 0.2 0.3 S50UC-K0.3 250 0.28 0.42 S50UC-K0.42 250 0.38 0.58 S50UC-K0.58 250 0.53 0.8 S50UC-K0.8 250 0.73. S50UC-K. 250.5 S50UC-K.5 250.4 2. S50UC-K2. 250 2 3 S50UC-K3 250 2.8 4.2 S50UC-K4.2 250 C 8.90 3.8 5.8 S50UC-K5.8 250 5.3 8 S50UC-K8 250 7.3 S50UC-K 250 0 5 S50UC-K5 250 20 S50UC-K20 250 8 26 S50UC-K26 250 23 32 S50UC-K32 286 29 37 S50UC-K37 286 34 4 S50UC-K4 320 38 45 S50UC-K45 320 2 pole 0. 0.5 S502UC-K0.5 488 0. 0.2 S502UC-K0.2 488 0.2 0.3 S502UC-K0.3 488 0.28 0.42 S502UC-K0.42 488 0.38 0.58 S502UC-K0.58 488 0.53 0.8 S502UC-K0.8 488 0.73. S502UC-K. 488.5 S502UC-K.5 488.4 2. S502UC-K2. 488 2 3 S502UC-K3 488 2.8 4.2 S502UC-K4.2 488 3.8 5.8 S502UC-K5.8 488 5.3 8 S502UC-K8 488 7.3 S502UC-K 488 0 5 S502UC-K5 488 20 S502UC-K20 488 8 26 S502UC-K26 488 23 32 S502UC-K32 558 29 37 S502UC-K37 558 34 4 S502UC-K4 622 38 45 S502UC-K45 622 C 7.85 Rated Catalog List Delivery Weight current number price class (oz.) pc 3 pole 0. 0.5 S503UC-K0.5 $ 72 0. 0.2 S503UC-K0.2 72 0.2 0.3 S503UC-K0.3 72 0.28 0.42 S503UC-K0.42 72 0.38 0.58 S503UC-K0.58 72 0.53 0.8 S503UC-K0.8 72 0.73. S503UC-K. 72.5 S503UC-K.5 72.4 2. S503UC-K2. 72 2 3 S503UC-K3 72 2.8 4.2 S503UC-K4.2 72 C 25.36 3.8 5.8 S503UC-K5.8 72 5.3 8 S503UC-K8 72 7.3 S503UC-K 72 0 5 S503UC-K5 72 20 S503UC-K20 72 8 26 S503UC-K26 72 23 32 S503UC-K32 8 29 37 S503UC-K37 8 34 4 S503UC-K4 90 38 45 S503UC-K45 90 4 pole 0. 0.5 S504UC-K0.5 996 0. 0.2 S504UC-K0.2 996 0.2 0.3 S504UC-K0.3 996 0.28 0.42 S504UC-K0.42 996 0.38 0.58 S504UC-K0.58 996 0.53 0.8 S504UC-K0.8 996 0.73. S504UC-K. 996.5 S504UC-K.5 996.4 2. S504UC-K2. 996 2 3 S504UC-K3 996 C 35.75 2.8 4.2 S504UC-K4.2 996 3.8 5.8 S504UC-K5.8 996 5.3 8 S504UC-K8 996 7.3 S504UC-K 996 0 5 S504UC-K5 996 20 S504UC-K20 996 8 26 S504UC-K26 996 23 32 S504UC-K32 2 29 37 S504UC-K37 2 34 4 S504UC-K4 276 38 45 S504UC-K45 276 0,000 5000 S504UC-K0.5 UC-K Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 000 500 00 50 0 5 seconds 0.5 0. 0.05 DC 0.0 2 3 5 0 20 30 multiple of rated current Low Voltage Products & Systems Discount schedule CB0.39

S500 Series Accessories S500-H Auxiliary contacts Electrical Catalog List Delivery Wgt. oz. accessories number price class (pc.) Auxiliary contacts N.O./ N.C. S500-H 2 N.O. S500-H20 $ 84 B 2. 2 N.C. S500-H02 For field mounting left side Bell alarm with auxiliary contacts N.O./ N.C. S500-S 2 N.O. S500-S20 92 B 2. 2 N.C. S500-S02 For field mounting left side Handle mechanism S500-RD3 00 B 6.5 For use with -4 pole S500 MCBs and disconnect switch selector handles with 5mm shafts Electrical Catalog List Delivery Wgt. oz. accessories number suffix price class (pc.) Undervoltage release 2 V UA2 24 V UA24 48 V UA48 0 V UA0 230 V UA230 500 V UA500 Factory mount only. Shunt trip 2 V AL2 24 V AL24 48 V AL48 0 V AL0 230 V AL230 500 V AL500 Factory mount only. $ 266 B 5.7 224 B 5.7 S500-RD3 Front mounting kit For pole S500-ME 60 2. to 3 poles S500-ME2 70 A 2.9 to 7 poles S500-ME3 80 3.6 Power feed terminal Accepts into 2/0 AWG S500-K2 25 A 2 Suggested order quantity is 5. S500-K2 S500-BB38 Busbars 3 phase L, L2, L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity 3 x 8 650 S500-BB38 $ 82 50 4 x 4 435 S500-BB44 2 A 3 x 3 055 S500-BB33 274 Busbar end caps Electrical Catalog List Delivery Wgt. oz. accessories number price class (pc.) S500-EK $ 25 A 0 Weight (ozs) Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.40 Discount schedule CB8 Low Voltage Products & Systems

Technical data S500 Series Item S500-B, C, D S500-K Approvals: UL 077 077 CSA C22.2 - No.235 C22.2 - No. 235 VDE 064/6.78 064/6.78 IEC 947-2 No. of poles:,2,3, +N, +NA,2,3, +N, +NA Tripping characteristic: B.C.D. K Rated currents: 6 to 63A 0. to 45A Rated voltage: UL/CSA single pole 277VAC 277VAC UL/CSA multi pole 600YVAC 600YVAC IEC single pole 690VAC 690VAC Rated interrupting capacity: Single pole 6-25A 30KA/240VAC 0.5-25A 30KA/240VAC KA/277VAC KA/277VAC 32-63A 8KA/240VAC 26-45A 8KA/240VAC KA/277VAC KA/277VAC Multi-pole 6-63A KA/480VAC 0.5-45A KA/480VAC 6KA/600VAC 6KA/600VAC Frequency: 50/60 Hz 50/60Hz Mounting position: optional optional Standard mounting: 35mm DIN rail 35mm DIN rail Terminals: Conductors from 6-4AWG Conductors from 6-4AWG (-25sq mm) (-25sq mm) Service life at rated load: 20,000 operations 20,000 operations Calibration temperature: 40 C 40 C Approvals: UL CSA VDE No. of poles: Tripping characteristic: Rated currents: Rated voltage: UL single pole UL multi pole IEC multi pole Item S500UC-B, K 077 C22.2 0660,2,3, 4 B, K B: 6 to 63A K: 0.5 to 45A 277VAC/250VDC 600VAC/600VDC 690VAC/750VDC Rated interrupting capacity: B single pole: 6 25A 8KA/240VAC KA/277VAC 30KA/250VDC 32 63A 30KA/240VAC KA/277VAC 30KA/250VDC B two-pole: 6 63A KA/480VAC 6KA/600VAC 30KA/500VDC B three-pole: 6 63A KA/480VAC 6KA/600VAC 30KA/600VDC K single pole: 0.5 25A 30KA/240VAC KA/277VAC 30KA/250VDC 32 45A 8KA/240VAC KA/277VAC 30KA/250VDC K two-pole: 0.5 45A KA/480VAC 6KA/600VAC 30KA/500VDC K three-pole: 0.5 45A KA/480VAC 6KA/600VAC 30KA/600VDC Frequency: Mounting position: Standard mounting: Terminals: Service life at rated load: 50/60Hz optional 35mm DIN-rail Conductors from 6 to 4AWG (-25sq mm) 20,000 operations Low Voltage Products & Systems.4

S500 Series Approximate dimensions 00.00 00.00 Inches [Millimeters] S500 2.95 75.97 50 0.98 25 3.64 92.5.73 44 3.5 80 2.22 56.5.77 45 CL 2.95 75 3.62 92. 29 0.24 6 S500-RD3 Handle mechanism 3.5 80.60 40.7 S500 Front mounting kit CL.8 46 2.9 74 4.4 2 2.00 5 CUT-OUT "L" CL 0.24 D 6D L+0.5 3 L L +.02 26 3.3 84 0.3 8.42 Low Voltage Products & Systems

Galaxie circuit breakers GD, GH, GN & GV Galaxie circuit breakers Description Galaxie circuit breakers are door mounted for AC and DC applications. The breakers offer thermal-magnetic and magnetic-only trip protection. For the worldwide market, the Galaxie breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. Features Convenient actuators: Switch type, rocker switch & pushbutton Various termination mountings Tropicalization protection 480Y/277 VAC UL 077 Recognized supplemental protective device. UL File # E7574. Low Voltage Products & Systems.43

Galaxie circuit breakers GD, GH, GN & GV Series circuit breakers Fitted, unpluggable or projecting type Catalog number explanation Circuit Breakers SERIES GD Standard Galaxie AC 240/45 V 50/60 Hz can be used at 48 V DC max. GH High rupturing capacity Galaxie AC 240/45 V 50/60 Hz GN Special Galaxie 00 V DC max. GV Special Galaxie 50 V DC max. GA Severe environment Galaxie (i.e. military use) consult us VERSIONS U One-pole ( protected pole) B Two-pole (2 protected poles) T Three-pole (3 protected poles) Q Four-pole (4 protected poles) +N Two-pole ( protected pole + neutral) 3+N Four-pole (3 protected poles + neutral) RATING (In : Amps) 0. - 0.2-0.3-0.5 - -.5-2 - 2.5-3 - 4-5 6-8 - 0-2 - 3-6 - 20-25 - 30-32 Heavy duty types : ratings according to NF EN60 898 Other ratings, consult us. MODELS L Thermal-magnetic - Curve B according to NF EN60 898 U Thermal-magnetic - Curve C according to NF EN60 898 D Thermal-magnetic - Curve D according to NF EN60 898 Ratings 6 to 32 A S Thermal-magnetic (series GN and GV only) according to NF F 6200 T Thermal (except series GH) FASTENINGS AND OPERATIONS 00-0 - 02-03 - 04-05 - 06-07 - 08-09 OPTIONS RATING ENGRAVED J On resetting button METAL THREADED BUSHING W For fastening and operations 6-7-8. Tightening torque : 3 Nm max. (compulsory with option K) CIRCUIT BREAKER SERIES GD MODEL D 2 R With adjustable thermal protection (Not possible with option K) MECHANICAL IMPACT V 50 g E 00 G TROPICALIZATION T (Compulsory with option E 00) THERMAL PROTECTION C Temperature compensated from + 20 C to + 60 C K Temperature compensated from - 40 C to + 85 C series GD, GH and GA (Compulsory with Option W) AUXILIARY CONTACT FOR POSITION SIGNALLING O/F P on pole P2 on 2 poles P3 on 3 poles P4 on 4 poles See next page 2 Series GD, Model D only TERMINATIONS 00-0 - 02-03 - 07-08 - 09-33 - 43 EXAMPLE : Circuit breaker Series : Galaxie standard AC - Version : 2 protected poles - Rating : 0 A - Model : magnetic-thermal, curve C - Fastenings and operations : Threaded bushing flush type 2 buttons - Terminations : Screws and back connectors - With Options Auxiliary for position signalling O/F : on 2 poles - Tropicalization has reference GDB0U0703 P2T GD B 0 U 07 03 P2 - T - - - -.44 Low Voltage Products & Systems

Technical data Galaxie circuit breakers Characteristics SERIES GD SERIES GH SERIES GN SERIES GV Rated voltage + neutral version One pole version Multipole version One pole and two pole version Interrupting capacity According to standard IEC 898 According to standard NF F62 00 Other characteristics Life, number of cycles (On+Off) Dielectric withstanding voltage UL, CSA : For list of certified products : consult us Circuit breakers NF F62 00 : consult us 240 V AC (50/60 Hz) 240/45 V AC (50/60 Hz) 240/45 V AC (50/60 Hz) 45 V AC (50/60 Hz) 45 V AC (50/60 Hz) 48 V DC max. 00 V DC max. 50 V DC max. 3 000 A 4 500 A (models U and D: rating 5 A) 4 500 A (model L: rating 0 A) 000 A (48 V DC max.) 500 A 000 A (48 V DC max.) 0 In cal. < 5 A ; 20 In cal > 5 A 0 In cal. < 5 A ; 20 In cal > 5 A 0 In cal. < 5 A ; 20 In cal > 5 A 4 000 4 000 4 000 4 000 2 000 V rms 2 000 V rms 2 000 V rms 2 000 V rms Tripping curves () (2) S Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 0 In - Curve D : 0 In < S < 20 In < In Nominal current 0. to 2 A : 5 In < S < 0 In - 3 to 32 A : 7 In < S Mechanical shock Ambient temperature 30 g. 30 g. 30 g. 30 g. -5 C to 40 C -5 C to 40 C -25 C to + 70 C -25 C to + 70 C Low Voltage Products & Systems.45

Galaxie circuit breakers Approximate dimensions Fastenings and operations N o 00-0 - 02-03 - 04-06 - 07-08 Pole Pole Pole Pole Pole N N 2 N N 2 N 3 Width 2 Widths 3 Widths Fastenings / Operations 00 0 02 03 04 05 06 07 08 09 Size A 8 8 8 8 8 7,5 5 5 2 28 Size C 32 32 32 32 32 37 32 32 32 32 Terminations 00 0 02 03 33 43 07 08 09 Size B 5 4 4 2 4 4 4 4 Fastenings and operations N o 05-09 Four-pole circuit breaker : Fastening and operation N o 05 only NOTE : Neutral on pole N any Fastenings and operations Pole Pole Pole Pole Pole Pole Pole Pole Pole N 2 N N 3 N 2 N N 4 N 3 N 2 N Width 2 Widths 3 Widths = handle 4 Widths = 2 handles Fastenings and operations (3 poles max. except 02 : 2 poles and 05 : 4 poles) P R O J E C T I O N M O U N T I N G S C R E W F L U S H M O U N T I N G Maximum thickness of mounting panel : 3 mm. 3 mm. 3 mm. 6 mm. 6 mm. 6 mm. 6 mm. 00 0 02 03 04 05 06 07 08 09 Terminations Tightening torque :,8 Nm max.,8 Nm max.,8 Nm max. 3 Nm max. 00 0 02 03 33 43 07 08 09 6 A max. 240 A max. 6 A max. 6 A max. 6 A max. Except Fastening 08 2 poles max. 2 poles max. 2 poles max..46 Low Voltage Products & Systems

compact Residual current devices F200, F670 series Residual current devices 2 Pole 4 Pole Description RCDs provide ground fault equipment protection by monitoring the leakage of current to ground. The F200 and F670 series will trip when ground faults are detected in excess of the GF trip rating of the device. These devices provide GF protection only and are used in series with standard MCBs which provide overload and short circuit protection. The F200 and F670 series can be used as a main device providing GF protection for several MCB branch devices. The F200 and F670 series are UL053 recognized for use in 480Y/277VAC applications. The F202 and F672 is for use in single phase/two wire or two wire systems. The F204 and F674 is for use in three phase/four wire systems. The F200 and F670 series RCDs replace the F360, F370 and F660 series with no change in fit, form or function. The F200 and F670 have a profile similar to the S2 MCBs and can be used with the MCB busbars. Low Voltage Products & Systems.47

Residual current devices F202, F672 F204, F674 F200 & F670 Residual current devices Breaker GF trip Rated Catalog List Delivery Suggested Wgt. oz level current number price class order qty ( Pc.) F202 Two pole 0mA 6 F202AC-6/0.0 $ 500 F672 480Y/277VAC 30mA 25 F202AC-25/0.03 300 40 F202AC-40/0.03 400 63 F202AC-63/0.03 550 80 F672-80/0.03 600 00 F672-00/0.03 2200 Above devices are UL 053 recognized and IEC 008 approved. 00mA 25 F202AC-25/0. 300 40 F202AC-40/0. 400 B 3.8 63 F202AC-63/0. 550 80 F672-80/0. 600 00 F672-00/0. 2200 300mA 25 F202AC-25/0.3 300 40 F202AC-40/0.3 400 63 F202AC-63/0.3 550 80 F672-80/0.3 300 00 F672-00/0.3 800 F204 Four pole 30mA 25 F204AC-25/0.03 350 F674 480Y/277VAC 40 F204AC-40/0.03 450 63 F204AC-63/0.03 600 80 F674-80/0.03 300 00 F674-00/0.03 800 25 F674-25/0.03 800 00mA 25 F204AC-25/0. 350 40 F204AC-40/0. 450 63 F204AC-63/0. 600 80 F674-80/0. 300 00 F674-00/0. 800 B 9.0 25 F674-25/0. 800 300mA 25 F204AC-25/0.3 350 40 F204AC-40/0.3 450 63 F204AC-63/0.3 600 80 F674-80/0.3 200 00 F674-00/0.3 600 25 F674-25/0.3 600 500mA 25 F204AC-25/0.5 450 40 F204AC-40/0.5 600 63 F204AC-63/0.5 650 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.48 Discount schedule CB Low Voltage Products & Systems

Accessories F200 Residual current devices Auxiliary contacts Electrical For Catalog List Delivery Suggested Wgt. oz. accessories use on: number price class order quantities ( pc.) For field mounting: right side F200 S2C-H6R $ 36 A.4 Form C NO/ NC The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. Wire size: 8 AWG to 6 AWG. S2C-H6R Bell alarm For field mounting, right side F200 S2C-S/H6R 48 A.4 The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. The contact is rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. * Combination bell alarm/auxiliary contact S2C-S/H6R Shunt trip For field mounting, right side F200 S2C-A A: 2-60 VAC (2-60VDC) S2C-A2 A2: 0-45 VAC (0-250 VDC) 38 A 5.2 For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Shunt trips are available for on control system voltage (2-45 VAC/VDC). S2C-A_ Undervoltage release For field mounting, right side 2 VDC S2C-UA2 24 VAC S2C-UA24 48 VAC F200 S2C-UA48 0 VAC S2C-UA0 26 A 5.2 220 VAC S2C-UA230 380 VAC S2C-UA400 When control voltage drops below approximately 50% of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory. Factory mounting All accessories can be easily mounted in the field. For factory mounting of any accessory devices, add $30 list to total price per breaker. To create complete catalog number, take suffix of accessory device following S2C- and add suffix to end of breaker part number. Multiple suffixes must be added in alphabetical order. S2C-UA_ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Please consult factory for F670 accessories. Low Voltage Products & Systems Discount schedule CB8.49

Residual current devices Technical data F200, F670 F200AC F670 Electrical features Standards UL 053 & IEC 6008 UL053 & IEC 6008 Poles 2P, 4P 2P, 4P Rated current In 6,25,40,63 AMPS 2P- 80,00 4P- 80,00,25 Rated Voltage Ui 480Y/277 VAC 480Y/277 VAC Max operating voltage of curcuit test 254 (440 for F200 left neutral) 254 (440 for left neutral) Min operating voltage of circuit test 0 ( 95 for F200 left neutral) 0 ( 95 for left neutral) Rated Frequency 50 60 Hz 50 60 Hz Rated conditional 50 60 Hz 50 60 Hz Short-circuit current 0 KA 0 KA Rated residual breaking capacity KA 2 KA Rated impulse withstand voltage (.2/50) Uimp 6 KV 6 KV Power- frequency voltage dielectric strength 2.5 KV 2.5 KV Surge current resistance acc. To VDE 0432 Part 2 (wave 8/20) 250 AMPS 250 AMPS Mechanical features Toggle Blue sealable in ON-OFF position Blue sealable in ON-OFF position Contact position indicator yes yes Electrical Life 0000 0000 Mechanical life 20000 20000 Ambient temperature -25 C +55 C -25 C +55 C Storage temp. -40 C +70 C -40 C +70 C Installation Terminal Type failsafe bidirectional cylinder-lift terminal at top and bottom (shock protected) Terminal size top/bottom per cable 6 AWG Max. 6 AWG Max. Tightening torque 7.5 in-lb max. 7.5 in-lb max. mounting 35mm din rail by means of fast clip 35mm din rail by means of fast clip Connection From top & bottom From top & bottom Withdraw from busbar Possible without the use of tools Possible without the use of tools Approximate dimensions 2 Pole mm 85x69x35 MM 85x69x35 MM 4 Pole mm 85x69x70 MM 85x69x70 MM Weight 2 Pole g 200g 200g 4 Pole g 350g 350g Combination with auxiliary elements Auxiliary contact yes yes signal contact/ auxiliary switch yes yes shunt trip yes yes undervoltage release yes yes.50 Low Voltage Products & Systems

00.00 00.00 Inches [Millimeters] Approximate dimensions Circuit diagrams F200, F670 Residual current devices Approximate dimensions Circuit diagrams To use on 3p/3w systems, add jumper between 4 and 8N for operation of test button. Low Voltage Products & Systems.5

Residual current devices Notes.52 Low Voltage Products & Systems

compact Modular DIN rail components E220 - E270 Series Modular DIN rail components Description Safe connection by box terminals Captive screws with Pozidrive slotted head, Pozidrive system, Gr. Snap-on labels available Quick mounting with snap-on clip, easily accessible and detachable at the bottom Protection against unintentional direct touch System approach for control and circuit protection Compact size that dimensionally matches the S2 MCB series Control and pilot functions can be along side protective devices DIN rail mounted with 45mm front opening For use in auxiliary and logic devices Provide additional user functions for system control and operation Include pushbuttons, indicating lights and selector switches ABB System Pro M compatibility Most devices are both UL 508 recognized and are IEC compliant Labeled with the CE Mark Low Voltage Products & Systems.53

Modular DIN rail components E22 & E222 Switches, 240VAC 6 & 25A E22-0 Type Rated Catalog List Delivery Suggested Weight (Oz.) current number price schedule order qtys piece Switches N.O. + N.C. 6 E22- $ 90 2 N.O. + 2 N.C. 6 E22-22 77 B 0 2.46 3 N.O. + N.C. 6 E22-3 77 N.O. 6 E22-0 59.94 2 N.O. 6 E22-20 0 B 0 2.2 3 N.O. 6 E22-30 20 2.29 4 N.O. 6 E22-40 59 2.47 N.O. + N.C. 25 E222-0 2.47 N.O. 25 E222-0 07.94 2 N.O. 25 E222-20 B 0 2.2 3 N.O. 25 E222-30 59 2.29 4 N.O. 25 E222-40 239 2.47 Form C switches Change-over contact 6 E22-6 69 B 0 2.2 2 Change-over contacts 6 E22-6/2 25 2.47 Change-over contact 25 E222-6 28 B 0 2.2 Form C switches (I-O-II, Hand-OFF-Automatic) Pole 6 E22-4 99 B 0 2.2 2 Pole 6 E22-4/2 7 2.47 Pole 25 E222-4 50 B 0 2.2 Note: Above devices are UL 508 recognized and IEC certified. A300 pilot duty UL file # E7252 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.54 Discount schedule CB20 Low Voltage Products & Systems

E24 - E274 Disconnect switches 45, 63, 80 & 00A Modular DIN rail components Page Deleted 4/24/06 Low Voltage Products & Systems.55

Modular DIN rail components E225 - E229, E0 Pilot devices Type Catalog List Delivery Pack Weight (Oz.) number price schedule units pcs. piece Pushbutton, N.O. + N.C. contact Grey Red Green Yellow Black Blue E225-B E225-C E225-D E225-E E225-F E225-G $ 75 A 0.94 E225-F Illuminated pushbutton, N.O. contact with lamp, 20 VAC Clear E227-0B/0 Red E227-0C/0 Green E227-0D/0 00 Yellow E227-0E/0 Blue E227-0G/0 A 0.94 E227-0E E233-20/60 Pilot light with lamp, 20 VAC Clear E229-B/0 Red E229-C/0 Green E229-D/0 93 A 0.59 Yellow E229-E/0 Blue E229-G/0 Lamps 24 VAC/DC E0/24 20 VAC/DC E0/0 24 A 0. 220 VAC/DC E0/220 Note: Above devices are UL 508 recognized and IEC certified. UL file # E7252 Special features Safe connection via box terminals Captive screws with Phillips/Slotted head, Posidriv system, Gr. Snap-on labels available Protection against unintentional touch acc. to DIN VDE 006 Part 00 Lenses and pushbuttons in six colors Elapsed time meter Type Catalog List Delivery Pack Weight (KG) number price schedule units pcs. piece 24 VAC, 60 Hz E233-24/60 B 20 VAC, 60 Hz E233-20/60 $ 30 A 0.045 240 VAC, 60 Hz E233-240/60 B Non-resettable 00,000 hours (99999.99) UL file #7252 Sockets Type Catalog List Delivery Pack Weight (KG) number price schedule units pcs. piece E75 Socket, 250 VAC, 50/60 Hz E73 $ 57 B 0.2 Italian standard Socket, 250 VAC, 50/60 Hz E74 $ 57 B 0.2 French standard Socket, 250 VAC, 50/60 Hz E75 $ 57 B 0.2 Schuko standard Socket w/cover, 250 VAC, 50/60 Hz E75-C $ 57 B 0.2 Schuko standard E75-C Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.56 Discount schedule CB20 Low Voltage Products & Systems

Digital meters Modular DIN rail components Measuring instruments Type Catalog List Delivery Pack Weight (KG) number price schedule units pcs. piece Digital timer, 230 VAC, 50/60 Hz DTS7/ $ 422 B 0.3 Voltmeter 600 VAC, 50-400 Hz VLMD--2 50 B 0.3 Ammeter 5-20-25-40-60A, AMTD- 50 B 0.3 250-400-600A, 50-400 Hz DTS7/ Transformer, 230 VAC, 50/60 Hz TM5/2 35 B 0.3 4-8-2 VAC sec VLMD--2 TM5/2 Low Voltage Products & Systems.57

Modular DIN rail components Technical data Components for quick mounting onto DIN rails (35mm) Mounting depth: 68mm Mounting width:, 2, 3 and 4 pole switches = 7.5mm (= module) E220 Switches, 6 & 25A Switching capacity:.25 I n,.u n, cos j = 0.6 Short-circuit withstanding capacity: 3 ka, 380V, cos j = 0.9 Toggle sealable: In ON and OFF positions Connection cross-sections: Up to x 6mm 2 or 2 x 2.5mm 2 Rated AC voltage: 240 VAC UL/CSA (E7252) 250/440 VAC IEC E240/270 Disconnect switches, 45, 63, 80, & 00A Switching capacity:.25 I n,.u n, cos j = 0.3 Short-circuit withstanding capacity: E240 = 0kA, E270 = 25kA RMS Connection cross-sections: E240 up to 25mm 2 E270 up to 50mm 2 Rated AC voltage: 240/400/45 VAC E Series components for quick mounting onto DIN rails (35mm) Mounting depth 68mm Mounting width: 7.5mm (= module) Color: RAL 7035, grey Connection cross sections: Up to X 6mm 2 or 2 X 2.5mm 2 Rated current: 6A Rated voltage: 250 VAC IEC Rated voltage: 240 VAC UL/CSA (E7252) Terminal markings 5 7 3 3 5 7 3 5 7 3 3 3 5 3 5 7 2 4 6 8 2 4 6 8 2 4 2 2 4 2 4 6 2 4 6 8 2 6 4 8 2NO&2NC Switches 3NO&NC 2NO NO 2NO 3NO Disconnect switches 4NO 3 3 7 3 5 7 3 3 7 5 0 I II 3 0 I II 3 7 5 2 2 8 2 6 8 2 2 8 2 2 8 NO 2NO 3NO Pole 2 Pole Pole 2Pole Illuminated pushbutton Form "C" switches Form "C" switches (Hand - OFF- Auto) Terminal assignments for pushbuttons and indicator lights 5 7 3 7 5 2 6 4 8 2 8 6 2 MAX 2W 2 2 MAX 2W NO&NC NO Illuminated NO Pushbutton Pilot light.58 Low Voltage Products & Systems

00.00 00.00 Inches [Millimeters] Approximate dimensions Modular DIN rail components E220.77 45.0 3.35 85.0 3.35 85.0.99 50.5 2.52 64.0 0.69 7.5 Pilot light 0.69 7.5 Pushbutton E220, 6 & 25A.77 45.0 3.35 85.0.99 50.5 2.52 64.0 0.69 7.5 E233.97 50.0.77 45.0 3.35 85.0 2 3 4 5 9 9 2.52 64.0 0.69 7.5 E240/270.77 45.0 3.52 89.5.99 50.5 2.52 64.0 0.69 7.5.38 35.0.38 52.5 2.76 70.0 Low Voltage Products & Systems.59

Modular DIN rail components E73 - E75 Approximate dimensions DTS VLMD, AMTD TMS.60 Low Voltage Products & Systems

Transient voltage surge suppressors Transient voltage surge supressors TVSS, OVR range Description Compact DIN rail mounting Broad range, 2, 3, & 4 pole versions Replaceable plug cartridges Finger safe 5, 40, 65 & 00 ka versions Three position visual status indication Auxiliary contact for remote signalling UL 49, File # E238957 & E22406 Low Voltage Products & Systems.6

Transient voltage surge suppressors General points on lightning and its risks Causes of transient overvoltages The most serious consequences of lightning are the death of people and farm animals, and the destruction of equipment: telephone lines, transformers connected to the electrical distribution network, electrical meters, household appliances, etc. At the same time, the growing amount of equipment incorporating very sensitive electronic devices increases the number of incidences linked to lightning. Within companies, if office automation equipment or machines (in factories) are put out of action, it nearly always leads to operating losses, the cost of which is much more than that of the damaged equipment. For example, if a bank s computers are no longer operational, it suffers large operating losses. For the general public, the damage is mainly material: computer, household appliances, home cinema, etc. ROBUSTNESS OF EQUIPMENT 950 970 2000 Causes of transient overvoltages A transient overvoltage is a voltage peak with a maximum duration of less than one millisecond. There are two possible causes of overvoltages on electrical networks: natural causes (lightning), other causes due to equipment or switching devices. PROPAGATION OF DISTURBANCES 950 970 2000 Natural overvoltages on low voltage networks are caused by direct lightning strikes. The high level of energy contained in a direct lightning strike on a lightning conductor or an overhead low voltage line leads to considerable damage of the installation. The overvoltage can be over 20 times the nominal voltage. Operating or switching overvoltages linked to a network s equipment create overvoltages of a lower level (3 to 5 times the nominal voltage) but occur much more frequently, thus causing premature ageing of the equipment. Three categories of overvoltage propagate on low voltage networks: direct lightning strikes, indirect effects of lightning strikes, operating or switching overvoltages. Propagation of overvoltages by electrical networks (power and low current).62 Low Voltage Products & Systems

General points on lightning and its risks Causes of transient overvoltages Transient voltage surge suppressors Overvoltages due to direct lightning strikes These can take two forms: When lightning strikes a lightning conductor or the roof of a building which is earthed, the lightning current is dissipated into the ground. The impedance of the ground and the current flowing through it create large difference of potential: this is the overvoltage. This overvoltage then propagates throughout the building via the cables, damaging equipment along the way. When lightning strikes an overhead low voltage line, the latter conducts high currents which penetrate into the building creating large overvoltages. The damage caused by this type of overvoltage is usually spectacular (e.g. fire in the electrical switchboard causing the destruction of buildings and industrial equipment) and results in explosions. Direct lightning strike on a lightning conductor or the roof of a building Direct lightning strike on an overhead line Overvoltages due to the indirect effects of lightning strikes The overvoltages previously mentioned are also found when lightning strikes in the vicinity of a building, due to the increase in potential of the ground at the point of impact. The electromagnetic fields created by the lightning current generate inductive and capacitive coupling, leading to other overvoltages. Within a radius up to several kilometres, the electromagnetic field caused by lightning in clouds can also create sudden increases in voltage. Although less spectacular than in the previous case, irreparable damage is also caused to so called sensitive equipment such as fax machines, computer power supplies and safety and communication systems. Increase in ground potential Magnetic field Electrostatic field Low Voltage Products & Systems.63

Transient voltage surge suppressors Different types of surges Equipment containing electronic switching components is also likely to generate electrical disturbances comparable to overvoltages. The consequences of which on sensitive equipment, albeit not visible, are no less detrimental: premature ageing and unpredictable or fleeting breakdowns. Operating overvoltages are produced when reactive or capacitive equipment is switched on and off. Furthermore, interrupting factory production, lighting or transformers can generate overvoltages which will themselves cause greater damage to nearby electrical equipment. Direct lightning strikes Indirect lightning strikes Operating overvoltages Harmonics Micro breaks Temporary phenomenon Duration > 200ms Too long for TVSS Transient phenomenon Duration < ms TVSS needed Representation of the various disturbances on electrical networks Different type of power supply disturbances Atmospheric discharges Industrial interferences Switching operations on the power distribution system Main effects Destruction of the equipment Premature aging Incorrect operations.64 Low Voltage Products & Systems

OVR Range Main features Transient voltage surge suppressors TVSSs protect installations by limiting transient overvoltages and run-off lightning currents for electric and electronic equipment. They are divided into three families: Type 2 TVSSs provide protection for equipment against transient overvoltage and they are installed in the Main Switch Board (MSB), or in the Sub-Distribution Board (SDB). In addition to the standard TVSSs, two options are available: the Safety reserve system and the remote indication (TS), in order to ensure a preventive maintenance of the installation. ABB TVSS (OVR range) offer the same plus advantages of the other compact devices, in order to get a perfect compatibility with all the modular range of products. All these TVSS products comply with the international standard IEC 6643- and the European standard EN 6643-. They also comply with UL 49 and CSA C22.2. ABB safety reserve system Contact for alarm connection Pluggable unit / replacement modules DIN rail unit, easy installation and wiring Low Voltage Products & Systems.65

Transient voltage surge suppressors Technical data OVR range Electrical features Mechanical features Installation Dimensions and weight Technical Features Type 2 Standards IEC 6643- / EN 6643- / UL99 / CSA Type / test class T2 / II Poles P / P+N / 3P / 3P+N / 4P Types of networks TNS - TT - TNC - IT / Wye / Delta Type of current A.C. Nominal voltage Un V All US network voltages Max. cont. operating voltage Uc (L-N / L-PE / N-PE) V 50 / 275 / 320 / 440 / 550 / 660 Voltage protection level Up at In (L-N / L-PE / N-PE) kv 0.6 /.2 /.4 /.8 / 2.5 / 2.9 Nominal discharge current In (8/20) ka 5 / 5 / 20 / 30 Maximal discharge current Imax (8/20) ka 5 / 40 / 65 / 00 Impulse current Iimp (0/350) ka / Follow current If i ka None Operating current Ic ma < Short circuit withstand Icc ka 50 Disconnector gg - gl fuse A 6-25 curve C circuit breaker A 0-40 curve K circuit breaker Stocking temperature C -40 to +80 Operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 V2 Material of Housing PC grey RAL 7035 Maximal altitude m 2000 Integrated thermal disconnector Yes State indicator Yes Compatibility with OVR Sign Yes Safety reserve Option TS remote indicator Option Wire range L/N solid wire mm 2 2.5... 25 stranded wire mm 2 2.5... 6 Stripping length L/N mm 2.5 Tightening torque L/N Nm 2 Wire range PE solid wire mm 2 2.5... 25 stranded wire mm 2 2.5... 6 Stripping length PE mm 2.5 Tightening torque PE Nm 2 Pole dimensions (H x D x W) mm 85 x 58 x 7.5 Pole weight g 20 Technical Features of the integrated auxiliary contact Electrical features Contact complement NO ( make contact), NC ( normally closed contact) Min. load 2V D.C. - 0 ma Max. load 250V A.C. - A Installation Connection cross-section mm 2.5.66 Low Voltage Products & Systems

OVR Range Single pole Transient voltage surge suppressors Transient voltage surge suppressor Function: TVSS provides protection for equipment against transient overvoltage (indirect lightning strike) that occur on the electrical network (mains); the maximum discharge current (Imax) ranges from 5 to 00 ka per pole, based on MOV technology. Application: residential, commercial, industrial Standard: CEI 6643- / EN 6643- / UL 49 / CSA 8/20 current wave Type 2 - Surge Protection Devices Single pole Max Discharge Current (KA) 5 40 65 00 Nominal Voltage (V) MOV Voltage (V) Voltage Protection Level Up (KV) Catalog number List price 20 50.06 OVR 5 50 $ 230 OVR 5 50 s P 350 230 275.2 OVR 5 275 220 OVR 5 275 P TS 340 277 320.4 OVR 5 320 220 400 440.8 OVR 5 440 220 OVR 5 440 P 350 480 550 2.5 OVR 5 550 275 600 660 2.9 OVR 5 660 290 20 50 0.6 OVR 40 50 s P 440 OVR 40 50 s P TS 50 230 275.2 277 320.4 400 440.8 OVR 40 275 P 320 OVR 40 275 s P 345 OVR 40 275 s P TS 400 OVR 40 320 P 320 OVR 40 320 s P 350 OVR 40 320 s P TS 405 OVR 40 440 285 OVR 40 440 s P 350 OVR 40 440 s P TS 400 480 550 2.5 OVR 40 550 435 OVR 40 550 s 475 600 660 2.9 OVR 40 660 s 490 20 50 0.6 OVR 65 50 s P 395 230 275.2 OVR 65 275 s P 490 OVR 65 275 s P TS 565 277 320.4 OVR 65 320 s P 495 OVR 65 320 s P TS 520 400 440.8 OVR 65 440 s P 465 OVR 65 440 s P TS 530 480 550 2.5 OVR 65 550 s 600 600 660 2.9 OVR 65 660 s 675 230 275.2 OVR 00 275 s P 830 OVR 00 275 s P TS 955 277 320.4 400 440.8 OVR 00 320 s P 890 OVR 00 320 s P TS 025 OVR 00 440 s 800 OVR 00 440 s P 870 OVR 00 440 s P TS 005 Network N Single phase (left), neutral (right) 3N Three phase (left), neutral (right) N Neutral (left), single phase (right) N3 Neutral (left), three phases (right) 3L Three poles 4L Four poles Nothing Single pole Max. discharge current 8/20 I max (ka) 5 40 65 00 OVR N 65 275 s P TS TS Integrated remote indication P Pluggable unit Nothing: Single block s with safety reserve Max. continuous operating voltage U c (V) 660 550 440 385 320 275 50 75 Low Voltage Products & Systems Discount schedule CB5.67

Transient voltage surge suppressors OVR TVSS Multi-pole Transient voltage surge suppressor Function: TVSS provides protection for equipment against transient overvoltage (indirect lightning strike) that occur on the electrical network (mains); the maximum discharge current (Imax) ranges from 5 to 00 ka per pole, based on MOV technology. Application: residential, commercial, industrial Standard: CEI 6643- / EN 6643- / UL 49 / CSA 8/20 current wave Max Discharge Current (KA) 5 40 65 Nominal Voltage (V) MOV Voltage (V) Voltage Protection Level Up (KV) 20 50 0.6 Catalog number List price OVR N 5 50 $ 365 OVR N 5 50 s P TS 665 OVR 3N 5 50 625 230 275.2 OVR 3L 5 275 P 625 OVR 3N 5 275 690 277 320.4 OVR 3N 5 320 980 20 50 0.6 230 275.2 OVR N 40 50 s P 665 OVR N 40 50 s P TS 935 OVR 3N 40 50 s P TS 60 OVR 3N 40 275 s P 20 OVR 3L 40 275 s P 950 OVR 3N 40 320 P 75 277 320.4 OVR 3N 40 320 s P 250 OVR 3N 40 320 s P TS 50 400 440.8 OVR 3N 40 440 s P 290 20 50 0.6 230 275.2 277 320.4 400 440.8 00 277 320.4 OVR N 65 50 s P 000 OVR 3N 65 50 s P 535 OVR 3N 65 50 s P TS 640 OVR 3L 65 275 s P 045 OVR 3N 65 275 s P 280 OVR 3N 65 320 s P 650 OVR 3N 65 320 s P TS 900 OVR 3N 65 440 s P 245 OVR 4L 65 440 s 320 OVR 3N 00 320 s P 3200 OVR 3N 00 320 s P TS 3600 Network N Single phase (left), neutral (right) 3N Three phase (left), neutral (right) N Neutral (left), single phase (right) N3 Neutral (left), three phases (right) 3L Three poles 4L Four poles Nothing Single pole Max. discharge current 8/20 I max (ka) 5 40 65 00 OVR N 65 275 s P TS TS Integrated remote indication P Pluggable unit Nothing: Single block s with safety reserve Max. continuous operating voltage U c (V) 660 550 440 385 320 275 50 75.68 Discount schedule CB5 Low Voltage Products & Systems

OVR Range Very low voltage transmission lines protection Transient voltage surge suppressors Transmission line surge arresters (OVR TC) provide protection against transient overvoltages for equipment connected to telephone lines (digital or analog) & current loops. Standards Info: Modular low current surge arresters comply with IEC 6643-2 / UL 49. Schematic diagrams L L l L2 L2 l2 OVR TC 06 V OVR TC 200 V in parallel OVR TC / xx V / 200 FR in series Dimensions Dimensions (mm) W H D OVR TC (all models) 7.5 85 63 Connection L L2 L L2 OVR TC 200 FR OVR TC 200 V OVR TC 200 FR OVR TC 48 V OVR TC 24 V OVR TC 2 V OVR TC 06 V OVR TC 200 V in parallel l l2 OVR TC / xx V / 200 FR in series Fixing Simply clips onto DIN rail. Pratical info: Telecom and dataline protection surge arresters are installed in electrical switchboards or enclosures using DIN rail. Low Voltage Products & Systems.69

Transient voltage surge suppressors Technical data Electrical characteristics 6 V 2 V 24 V 48 V 200 V 200 V OVR TC 06 V OVR TC 2 V OVR TC 24 V OVR TC 48 V OVR TC 200 V OVR TC 200 FR Types of network Communication Communication Communication Communication Communication Communication Number of pairs Type of protection Series Series Series Series Parallel Series Type of current Low currents Low currents Low currents Low currents Low currents Low currents Nominal voltage: U n 6 V 2 V 24 V 48 V 200 V 200 V Max cont operating voltage: U c 7 V V 27 V 53 V 220 V 220 V Voltage protection level: U p at I n 5 V 20 V 35 V 70 V 700 V 300 V Nominal discharge current: I n (8/20) 5 ka 5 ka 5 ka 5 ka 5 ka 5 ka Maximum discharge current: I max (8/20) 0 ka 0 ka 0 ka 0 ka 0 ka 0 ka Bandwidth 0 MHz 2 MHz 4 MHz 6 MHz 00 MHz 3 MHz Operating current: I c 20 ma 20 ma 20 ma 20 ma - 20 ma Degree of protection IP 203 IP 203 IP 203 IP 203 IP 203 IP 203 50 Hz withstand (5 mn) 0 A 0 A 0 A 0 A - 0 A Mechanical characteristics L/N connection terminals: solid wire 0.5... 2.5 mm 2 stranded wire 0.5... 2.5 mm 2 PE connection terminal: solid wire 0.5... 2.5 mm 2 stranded wire 0.5... 2.5 mm 2 Integrated thermal disconnector Yes No Yes End of life indicator Yes No Yes Compatibility with OVR Sign Yes No Yes Miscellaneous characteristics Storage temperature -40 C to +80 C Operating temperature -40 C to +80 C Maximum altitude 2000 m Case material PC grey RAL 7032 Insulating material UL94 V0 classification Reference standard IEC 6643-2 / UL 49 Weight 50 g.70 Low Voltage Products & Systems

Installation rules Principles of coordination for TVSS Transient voltage surge suppressors The first surge arrester does not provide effective protection for the whole installation by itself. Certain electrical phenomena can double the protection s residual voltage if cable lengths exceed 0m. Surge arresters must be coordinated when they are installed refer to the tables below. Coordination required if: The first surge arrester does not reach the protection voltage (U p ) by itself. The first surge arrester is more than 0m away from the equipment to be protected. The first surge arrester diverts most of the current to the ground and the remaining surge current is diverted to the ground by the second surge arrester. The value of this remaining surge current gets lower as the distance between both surge arresters gets longer. The lower is the current going through the last surge arrester, the lower is the voltage protection level applied to the downstream equipment. Coordination between Type 2 TVSS units TVSS 65 ka 8/20 L > m ( m minimum between the two devices) TVSS 5 ka 8/20 Low Voltage Products & Systems.7

Transient voltage surge suppressors Approximate dimensions OVR range Transient voltage surge suppressor TVSS without TS 63 TVSS with TS 63 87.3 45 95.6 87.3 45 97 40 40 pole 3 poles 7,6 52,8 OVR 5 275 P OVR 5 440 P OVR 40 275 P OVR 40 275 s P TS OVR 40 440 P OVR 40 440 s P TS OVR 65 275 s P TS OVR 65 440 s P TS OVR 3L 5 275 P OVR 3L 40 275 P OVR 3L 40 275 s P TS OVR 3L 65 275 s P TS 4 poles 3 poles + Neutral 70,4 OVR 4L 5 275 P OVR 4L 40 275 P OVR 4L 40 275 s P TS OVR 4L 65 275 s P TS OVR 3N 5 275 P OVR 3N 40 275 P OVR 3N 40 275 s P TS OVR 3N 65 275 s P TS.72 Low Voltage Products & Systems

Technical details Installation rules for TVSS choice of associated breaking devices (fuse/circuit breaker) Transient voltage surge suppressors Choice of disconnector Surge arresters must be associated with upstream short-circuit protection and residual current protection against indirect contact (usually already present in the installation) Function Application Protection against fault currents The breaking device associated with the surge arrester can be either a circuit breaker or a fuse. Its rating should take into consideration the surge arrester s characteristics and the short-circuit current of the installation. Thermal protection Thermal protection is integrated into the surge arrester. Maximum circuit-breaker or fuse protection rating depending on I max and I imp of the surge arrester. TVSS surge arresters Circuit-breaker (curve K) Fuse (gg) 00 ka (8/20) I cc = 300 A to ka 40 A 25 A I cc = ka to 7 ka 40 A 25 A I cc = 7 ka and above 40 A 25 A TVSS surge arresters Circuit-breaker (curve C) Fuse (gg) 65 ka (8/20) I cc = 300 A to ka 30 A 20 A I cc = ka to 7 ka 32 A to 40 A 40 A I cc = 7 ka and above 32 A to 63 A 63 A 40 ka (8/20) I cc = 300 A to ka 25 A 6 A I cc = ka to 7 ka 25 A 25 A I cc = 7 ka and above 25 A to 50 A 50 A 5 ka (8/20) I cc = 300 A to ka 0 A to 25 A 6 A I cc = ka to 7 ka 0 A to 32 A 6 A I cc = 7 ka and above 0 A to 40 A 25 A to 40 A Low Voltage Products & Systems.73

Transient voltage surge suppressors Technical details Cabling and installation of Surge Protection Devices in an electrical panel 50 cm rule Remember that a 0 ka lightning current passing through a m length of cable generates 000 Volts. Equipment protected by a surge arrester is subjected to a voltage equal to the sum of the U p voltage of the surge arrester, U d of its disconnector and the sum of the inductive voltages of connecting cables (U+U2+U3). It is therefore essential that the total length (L = L+L2+L3) of the connecting cables is as short as possible (0.50 m). If this length (L = L + L2+L3) exceeds 0.50m, it is necessary to carry out one of the following: Reduce this length by moving the connection terminals. Choose a surge arrester with a lower U p value. Install a second, coordinated surge arrester near the device to be protected so as to adapt the combined U p value to the impulse withstand of the equipment to be protected. Wiring ring surfaces The wires must be arranged in such a way that they are as close to each other as possible (see adjacent diagram) to avoid overvoltages induced by a ring surface between phases, the neutral and the PE conductor. Routing of clean cables and polluted cables During installation, lay clean cables (protected) and polluted cables as shown in the adjacent diagrams. U U D U2 U P U3 L L2 L3 L To avoid magnetic coupling between the different cable types (clean and polluted), it is strongly advised that they are kept apart (> 30 cm) and if a crossing cannot be avoided, it should be at right angles (90 ). Polluted cables D > 30 cm Clean cables Polluted cable Crossing at 90 Clean cable Main circuitbreaker Terminal / MCB Ring surface Surge arrester circuitbreaker Feeder Clean cable Polluted cable D > 30 cm MCB / TVSS D < 30 cm Feeder 2 TVSS / Earth terminal Equipotential grounding: It is critical to check the earth equipotentiality of the various items of equipment. Note: The cross-section of the connecting cables is calculated according to the local short-circuit current level (where the surge arrester is installed). It must be equal to the cross-section of the installation s upstream cables. The minimum cross-section for the earth conductor is 4 mm 2 if there is not a lightning conductor and 0 mm 2 if there is a lightning conductor..74 Low Voltage Products & Systems

Application sheets OVR Surge Protection Devices Transient voltage surge suppressors Operating principle The Surge Protection Devices (TVSS), suitable for residential, commercial and industrial applications, are designed to limit transient overvoltage and run-off lightning currents. Application environments The Surge Protection Devices (TVSS) are necessary in any environment where the lightning risk exists (direct lightning strike / overvoltage). Example of installation As shown in the diagrams, one of the possible applications is to protect the equipment (TV, computer,...) against overvoltage thanks to a Surge Protection Device (TVSS) which ensures the protection in common mode (Ph-PE / N-PE) and differential mode (Ph-N). Type 2 TVSS Low Voltage Products & Systems.75