PD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06

Similar documents
PD Channel Digital IO PD Series 600

PD 667 DPI with RS485 Interface Profibus DP-V0 Essential Features Master PD Series 600

PD 600 DPI with RS-485 P-NET Interface PD Series 600

PD 600 DPI with RS-485 P-NET Interface PD Series 600

PD 601 DPI with RS-232 P-NET Interface PD Series 600

Damcos MAS G048 Inclinometer

DeltaV Bulk Power Supplies

Valve and Case Expansion Monitor Specifications

Manual Control Unit GFC 32

Control D. Controller Module for Proportional Valve Control. Installation Manual

CSI 9330 Vibration Transmitter

M-series Intrinsically Safe I/O

Manual Simatek Control Unit GFC 32

DeltaV Bulk Power Supplies

Deaerator and Surge Tank Control

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Applications of Programmable Logic Controllers DG31 34

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

AS-i Safety Relay Output Module with Diagnostic Slave

Signal Doublers. VariTrans A 20300

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

Installation & Operation and Maintenance

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

MODEL SIB-V245 / V453

AI-917-A0. Analogue Input Module (4x 0-20 ma)

SS2200 Remote Controller

NE1A/DST1. DeviceNet Safety System

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

BMS Steam Station Solutions

EXOcompact Third Generation Manual

Central Processing Unit - CPU

SensoTrans DMS A 20220

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

AirTest Model CN9000 Series Sensor Controller

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

AS-i Safety Relay Output Module with Diagnostic Slave

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

SWING Ultrasonic Level & Flow Controller

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

4-step Chiller and Heat Pump Controller

MODEL 9250 Preliminary data sheet

P216. Condenser fan speed controller. Product bulletin. Features

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

Operating Instructions. For. Level Control Module. Model SSR 1000

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Solid State Remote Power Controller E /627

RWD68U Universal Controller

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual

S-series Mass Connection Solutions

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

LC-5 Level Controller & Flow Monitor

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

EM2020 Selectable AC transducer A (UK)

2301E ST Steam Turbine Control for Small Generator Applications

Shown with terminal block Supports diagnostic point fault contacts in the logic program

Project Execution Best Practices

SensoTrans DMS P 32200

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

Introduction. Upon completion of Basics of PLCs you should be able to: Identify the major components of a PLC and describe their functions

EEET 2204 Industrial Automation

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

EX200-HART. Compact Electronic Actuator Positioner for use in EX2010A System. Features. Simple two-step calibration

Sure Coat Modular Gun Control System Part C: Discrete I/O Interface Card. Customer Product Manual Part B

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

USER MANUAL. Valve System Test Centre 1/26

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

The TVC Positioner is designed to provide precise position control of rotary or linear hydraulic or pneumatic actuated valve systems.

SECTION THERMAL UTILITY METERING INTERFACE

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

DeltaV Electronic Marshalling for Migrations

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Electronic Control Options for Automatic Control Valves. Jody Malo Singer Valve

GPM500 Generator Protection Module

P216 Series Condenser Fan Speed Controller

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

S-series DeviceNet Interface Card

E-STOP relays, safety gate monitors

CLA-VAL Control Panel

Faults on the system Proximity switch connection technology:

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Siemens BACnet Programmable TEC Unit Conditioner Controller

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Transcription:

PD 527 Valve Control Module PD Series 600 Product Data Sheet February 2015 SD 8719-2E06

PD 527 Valve Control Module February 2015 Introduction The PD 527 Valve Control Module is specially designed to control the various types of Damcos valve actuators in the marine environment either by solenoid valve(s) or via an LPU (Local Power Unit). The PD 527 Valve Control Module is part of the 600 series (M36) controllers and IO modules. The PD 527 Valve Control Module consists of two units. The one being an electronic module including CPU, push buttons for local control, indication LEDs (Light Emitted Diodes), and communication. The other being a base unit BM 015 with mounting facilities to the DINrail, terminals for connection of power sources and external equipment and relays. In the following the PD 527 Valve Control Module is called PD 527. The PD 527 can be used in complete Marine Tank Management system, MTM, which includes: Valve control and operation Pump control and operation Tank contents gauging and calculation Draft, trim and heel measurement and calculation Interface to loading / stability computer Interface to ISC (Integrated Ship Control) system If P-NET communication is intended for valve control the PD 527 modules must be installed together with one of the following modules: DPI (Distributed Process Intelligence) SPI (Simple P-NET Interface) RPI (Redundant P-NET Interface This is done to enable interconnection of the valve actuator with other P-NET units, such as IO modules, display units, DPI / controllers, workstations for the shared fieldbus P-NET. The units are communicating with each other by means of the galvanic separated Light-Link P-NET Fieldbus. The system will maintain in operation even if one unit is exchanged. The PD 527 is fitted with two relay outputs to be connected to a solenoid valve or an LPU. There are inputs for connecting either two switches for end position feedback (On/Off) or one potentiometer for intermediate position feedback (analog). The PD 527 has internal push buttons for local control of the unit. The PD 527 has built-in LEDs for monitoring status and position feedback. 2 www.emersonprocess.com

February 2015 PD 527 Valve Control Module Due to internal isolation of position feedback inputs, the LPU may be connected with one cable only, without any risk of high voltage to destroy other modules. Apart from being controlled by the P-NET the PD 527 can be controlled from hardwired input or pushbuttons. It can be used as a stand-alone unit without P-NET but controlled by external hardwired inputs / outputs. P-NET is then applied in connection with end testing for configuration and test only. In this case control is done by 24 VDC inputs. Position feedback signal is given from 24 VDC outputs, or on a 4-20 ma indicator for valves with analog position indicator. A PLC can also be used for control and indication. The two discrete outputs are for On/Off position indication. When an input is high, the corresponding output is set. In intermediate positions both outputs are low. In case of a position indicator error, both outputs are high. The analogue 4-20 ma output is connected externally to the 0 from the 24 V DC supply. The 4 ma corresponds to 0% open and 20 ma to 100% open. An output current of 0 ma indicates a position indicator error. There are 4 possible modes (controlling) methods for the PD 527 control inputs: PulseMode ActiveMode DirectionModeOpen DirectionModeClose In DirectionMode the valve position (fully open or fully closed) can be controlled from one 24 VDC input, while the other input is used for enabling the valve movement. A common alarm output is also available on the unit to be used to signal any alarms to the external equipment / PLC. An ESD (Emergency Shut Down) input is also available on the unit. There are 3 possible controlling methods for the PD 527 ESD input: ESDClose which close the valve when ESD is set ESDOpen which open the valve when ESD is set ESDFailSet which keeps the valve in the actual position when ESD is set The built-in microprocessor executes and manages the actual control. This ensures an optimal control of the connected equipment, which is never overloaded. Complete MTM systems can be designed on the basis of the PD 527. MTM systems are designed to match the needs and requirements of each individual ship with respect to valve actuators location, cable installation, safety, control of other machinery, data acquisition and control of other measuring points, operation facilities centralised and decentralised. Supervision / operation of the valve actuators can take place from a P-NET master, i.e. a controller or a workstation. These units can be installed on the P-NET wherever operation is needed, e.g. on the bridge, in the cargo control room, engine control room or from local interface panels. The connected controllers / workstations can be configured to be redundantly related. This feature being an additional safety for the crew should any unit fail. Interlocks for the connected controllers / workstations can be implemented. In this way a certain group of valve actuators and attached equipment are operated from one location only, and simultaneous operation from more locations is prevented. An on-line connection can be established to the vessel s ISC (Integrated Ship Control) system for transfer of commands, status, alarms etc. The built-in microprocessor intensively monitors the unit, including the following errors / alarms: Program / RAM / EEPROM storage errors Watch dog run out (P-NET communication has stopped) Invalid set point value Invalid position transmitter system Position error (ActualPosition differs significantly from PositionSetpoint) Max run time (motor and pump protection) Motor overload (motor and pump protection) (only for LPU control) Max time (valve moves too slowly) Min time (valve moves too fast) As long as the ESD input is high, the valve is locked in the relevant position. www.emersonprocess.com 3

PD 527 Valve Control Module February 2015 The following are measured and displayed: Actual position analog feedback 0-100% On/Off feedback 0% (closed) 50% (middle) 100% (open) Valve status (stopped, opening, closing, settling, floating, ESD-locked) Operation mode (P-NET writing to the PositionSet-point or ValveStatus register), voltage input open, close or ESD), push buttons). The valve actuator can be controlled from a master in two ways: By transfer of a set-point to the PD 527, which takes over the actual control of the connected equipment and stops when the wanted set-point has been reached (Writing to the PositionSet-point) Direct control: Open / Close / Stop (Writing to the ValveStatus register) Another safety feature: The Block Set-point blocks the PD 527 so that the set-point cannot be changed from the P-NET. The valve cannot be moved from the HardWire inputs or the internal push buttons either. Control is still possible though, if the P-NET communication falls out for more then the pre-set watchdog, and this watchdog is enabled. The Block Setpoint is particularly used for protecting automated procedures. Another control feature: The Floating Set-point continuously copies the actual position to the set-point. No PositionError then rises, when the valve is moved. The function can be used when another control system shall be given ability to directly control the valve actuators. The Block Set-point and Floating Set-point can be used independently from each other or together. 4 www.emersonprocess.com

February 2015 PD 527 Valve Control Module Features 100% protection and control of the various valve LPU / actuators Only one unit for controlling all of the following LPU / solenoid valves: LPU Spring return LPU Double acting (motor two way rotation) 1) and 2) LPU Double acting 2A (motor one way rotation) 4/3 Double acting solenoid valve 4/3 Single acting with pressure controlled non-return valve (enabling spring return actuators to be stopped in intermediate positions, and still go to safe position if the pressure or electrical power falls out) 4/2 Detent solenoid valve 4/2 Spring return (FO and FC) solenoid valve Being a P-NET slave the PD 527 is an independent unit to be directly controlled from e.g. a workstation From the P-NET indication can be given how the valve was operated the last time From the P-NET change of set point can be blocked From the P-NET set point can be set to floating (the actuator can be controlled from another control system) AutoCorrection option (the PD 527 sets the valve back into it s position). This feature can be automatically disabled when no P-NET communication is present, in order to allow emergency operation of the valve if the P-NET fails Intelligent run on system continuously calculates the run on in both open and close direction. This feature is only used for valve actuators with analog feedback, in order to obtain accurate intermediate positions The presence of 24 VDC is displayed on the On LED The presence of internal error in the module, or absence of P-NET communication is displayed on the Error LED if the P-NET Watchdog is enabled. Indication on LED s, of valve position (Open, Closed, intermediate), status and position indicator error if any Good service / starting up facilities as the valve can be operated directly from push buttons, configurable as onetouch or press-while-running push buttons for opening or closing valves ESD function i.e. the 24 VDC control input can be configured for Emergency Shut Down The valve is controlled by using one or two control inputs (open / close) and two feedback outputs (open / closed), or one analogue 4-20 ma position feedback output Control inputs (open / close) can directly be connected to the PLC (24 VDC) Alarm output Possibility to calibrate the analog feedback by means of the Close and Open push buttons. Due to internal isolation of position feedback inputs, the LPU may be connected with one cable only, without any risk of high voltage to destroy other modules mounted on the same DIN Rail. 1. PLC or Power PCB in the LPU can be used. If the end position shall be maintained i.e. the hydraulic pressure in the LPU-S drops, the Power PCB must be selected, and the KeepActive function activated. 2. Double acting LPU without solenoid valve must be connected via external relays. With the following position feedback: On/Off Analog Remote www.emersonprocess.com 5

PD 527 Valve Control Module February 2015 Channel Structure The PD 527 Channel structure consists of 2 channels as shown in the table. Channel No. Name Description 0 Service Device identification, address and configuration 1 Actuator General purpose for valve control Wiring Diagram / Connection The connections for the PD 527 are shown below. Note! 1. The Input, Output and Feedback terminals all refer to 24 VDC supply. 2. The max. load on each output is 6 A (230 VAC). LED Indication Actual position Closed Open 0-3 % On Off 3-97 % On On 97-100 % Off On Error Flash 1 Hz Flash 1 Hz Note! If the given setpoint is not achieved (position error) the LED(s) showing the actual position will flash as follows: 250 ms Off and 1750 ms On. Time Time will Flash with 250 ms Off and 250 ms On (2 Hz) when the valve is moving too fast. Time will Flash with 250 ms On and 1750 ms Off when the valve is moving too slow. Locked On Error When SetPointBlocked or ESDmode is activated, the LED will be On. When the Watchdog has run out while the SetPointBlocked is activated, the valve can be operated by the push buttons or hardwire inputs. Under this condition, The LED will Flash with 250 ms On and 1750 ms Off. If the P-NET communication takes place again, the SetPointBlocked is active again. If the setpoint is changed during the Watchdog run-out, the SetPointBlocked is permanently reset. If ESDmode is activated the valve cannot be operated. The green On LED is turned on when the electronic module is powered with 24 VDC. The red Error LED is turned on when the electronic module is monitoring an internal error or if configured watchdog runs out (P-NET communication has stopped). 6 www.emersonprocess.com

February 2015 PD 527 Valve Control Module Technical Specifications Dimensions (in mm): Weight 140 grams approx. Power supply 18 to 32 VDC Current at power up max. 50 ma Ripple max. 5% Power consumption @ 24 VDC All outputs / inputs at ON max. 60 ma All outputs / inputs at OFF max. 30 ma Digital Input Switches: Encapsulated with gold coating max. 100mA Analog Input Potentiometer: 2 K Ohm Relay Output (BM 015) Load current max. 6 A (230 VAC) BM 015 base module is as standard equipped with a 6 A fuse PLC Digital Input 24 VDC Digital Output: 24 VDC / Max. 500 ma Analog Output 4-20 ma Operation Temperature 25 C to + 70 C Storage temperature 40 C to + 85 C Interface: Light Link www.emersonprocess.com 7

PD 527 Valve Control Module SD 8719-2E06 Product Data Sheet February 2015 Maritime Approvals Meets the requirements of all the major international marine classification societies. For more information see PDS for the PD Series 600 Introduction. More Information Please refer to the manufacturers manual for PD 527 Valve control. Emerson Process Management Damcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272 www.emersonprocess.com/mtm Emerson Process Management Rosemount Tank Radar AB Box 13045 SE-40251 Sweden T +46 31 337 00 00 F +46 31 25 30 22 www.emersonprocess.com/mtm 2015 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. Damcos and the Damcos logotype are trademarks of Damcos A/S. Damcos A/S and Rosemount Tank Radar AB are members of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Damcos A/S and Rosemount Tank Radar AB accepts no responsibility for any errors that may appear in this publication.