Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

Similar documents
NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

Network Automation Engine

Network Integration Engine

Network Control Engine Catalog Page

Network Integration Engine Product Bulletin

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

Application and Data Server (ADS) Lite-A System Catalog Page

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

Network Control Engine

NxE85 Commissioning Guide

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Network Integration Engine (NIEx9) for Third-Party Integrations Product Bulletin

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

Input/Output Module (IOM) Series Catalog Page

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

Metasys N1 Network Integration

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

LCS85 Product Bulletin

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3

Advanced Application Field Equipment Controller (FAC) Catalog Page

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

FX Input/Output (I/O) Modules XM07 and XM14

Medium User Interface (MUI) Version 3

Smart Equipment Controls (SEC)

LN Series Remote Input/Output (I/O) Modules

Metasys For Validated Environments, Extended Architecture Catalog Page

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

FX-PCA Advanced Application Programmable Controller Catalog Page

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

TC Modular Series for BACnet Networks

Metasys for Validated Environments, Extended Architecture Catalog Page

LX Series Remote Input/Output (I/O) Controller

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Metasys System Configuration Tool (SCT)

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

FXVMA Variable Air Volume (VAV) Box Controller

Application. NAE55 Installation Instructions * S* Installation. Parts included. Materials and special tools needed

NAE55/NIE55. Installation Instructions. MS-NAE55xx-x MS-NIE55xx-x. Application. Installation. North American Emissions Compliance.

NCE25 Installation Instructions MS-NCE25xx-x

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

TC-9102 Terminal Controller

PEAK TM. SMART Equipment Controllers. Product bulletin

TALON Network Manager- 2 & 6 Express

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

FX06 Field Controller

FX40 Supervisory Controller

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

TC Compact Series for BACnet Networks

Refer to the QuickLIT website for the most up-to-date version of this document.

Application and Data Server (ADS/ADX) Ready Computer Systems Product Bulletin

N2 Dialer Module. Features and Benefits

Installation Instructions for UL Rev A

Metasys Export Utility Product Bulletin

Issued February 14, 2014 Supersedes June 17, Refer to the QuickLIT website for the most up-to-date version of this document.

Web server. Simplified.

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

VMA Programmable VAV Box Controllers Catalog Page Code No. LIT Issued February 2018

FX-DIS Local Controller Display Technical Bulletin

Verasys System Product Bulletin

Field selectable application type and room module series, via dip-switches on controller

TC Compact Series Unitary Equipment Controller

2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 6

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Metasys System Software Purchase Options Product Bulletin

Clarity 3 GCE-8000 EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET

P216 Series Condenser Fan Speed Controller

Overview. Applications. Features

Cisco MCS 7825-I1 Unified CallManager Appliance

Savant Call Server: SCS-3000

FX Tools Express Software Package

Andover ContinuumTM. b3850 Series Terminal Controllers

DX-9100 Digital Controller, Version 2

FX14 Field Controller

VMA Programmable VAV Box Controllers Catalog Page

Cisco MCS 7816-H3 Unified Communications Manager Appliance

TC Compact Series for BACnet Networks

Web server. Simplified.

Host Controller: HST-4002

Application and Data Server (ADS) Lite-E Catalog Page

Cisco MCS 7825-H3. Supported Cisco Applications

Metasys System Software Purchase Options Product Bulletin

Priva Blue ID Communication module RS485 SC44

What's New for Metasys Release 8.0 Code No. LIT Software Release 8.0 Issued July 2016

CISCO MEDIA CONVERGENCE SERVER 7825-I1

ACX Series. Access Controller for Ethernet

HD Network Video Recorder Workstation

CONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES

Product Description. FX22, FX62, and FX70 Supervisory Controllers

ECLYPSE Communication Modules

PXC Modular Series for BACnet Networks

Comprehensive User/Group Security Restrict or allow access to myriad of points based on individual or group credentials

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

Metasys System Extended Architecture Overview

Savant Host: HST-4501

Transcription:

MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE8500-0 Code No. LIT-1900195 Software Release 6.5 Issued February 14, 2014 Supersedes June 17, 2013 Network Automation Engines (NAEs) provide comprehensive equipment monitoring and control, through key features such as scheduling, alarm and event management, energy management, data exchange, data trending, and data storage. These tools help reduce operation and energy costs for any type of building. This line of NAEs features and leverages IP connectivity and web-based access to Metasys Building Management Systems, including the BACnet protocol, the LONWORKS network, and the N2 Bus protocol, to monitor and supervise a wide variety of HVAC, lighting, security, and fire safety equipment. With the embedded Site Management Portal user interface, NAEs can support multiple concurrent web browser sessions with password and permission access control. To further enhance IT compatibility, NAEs employ standard IT security best practices. NAEs have an embedded UI and the capability to connect to and communicate with cloud-based applications. NAEs support concurrently connected web browsers. Specific features of NAE models include the following: NAE55 models support a comprehensive set of supervisory features and functions for large and technically advanced buildings and controllers. NAE35/NAE45 models enable cost-effective NAE connectivity and control in smaller facilities and can increase distribution of control in larger facilities. The NAE85 is a high-capacity NAE that is designed to provide supervisory level control of Metasys networks that include a large number of BACnet IP devices. Refer to the Network Automation Engine (NAE) Product Bulletin (LIT-1201160) for important product application information. Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface Refer to the QuickLIT website for the most up-to-date version of this document. Site Director Function Site Management Portal System Configuration Software Embedded in NAE User Interface and Online System Configuration Software Embedded in NAE Supervision of Field Controller Networks Including BACnet MS/TP, N2 Bus LONWORKS Network, and BACnet IP Devices Multiple Connection Options for Data Access Figure 1: NAE55 Network Automation Engine Repair Information If the NAE fails to operate within its specifications, replace the unit. For a replacement NAE, contact the nearest Johnson Controls representative. Ordering Information Contact the nearest Johnson Controls representative to order an NAE. Specify the desired product code from Table 1 for the NAE35, Table 2 for the NAE45, Table 3 for the NAE55, Table 4 for the NAE85, and Table 5 for accessories. Table 1: NAE35 Ordering Information MS-NAE35xx-x (Base Features of Each NAE35) MS-NAE3510-2 MS-NAE3510-2U MS-NAE3511-2 MS-NAE3514-2 NAE35 Network Automation Engines: Requires a 24 VAC power supply. Each model includes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 Data Protection Battery. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 50 devices on the BACnet MS/TP trunk. Note: This model is UL Listed, File S4977, UUKL 864-9th Edition Smoke Control Equipment. Also, in order to be UL/ULC compliant, this model must be pre-installed and pre-wired in a standard or custom panel built in the Johnson Controls Reynosa factory. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; limited to Basic Access support; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. 1

Table 1: NAE35 Ordering Information MS-NAE3515-2 MS-NAE3520-2 MS-NAE3521-2 MS-NAE3524-2 MS-NAE3525-2 Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; limited to Basic Access support; includes an internal modem; supports a maximum of 50 devices on the N2 Bus or BACnet MS/TP trunk. Supports one LONWORKS trunk; includes an additional RS-232-C serial port for optional external modem. Supports a maximum of 64 devices on the LONWORKS port. Supports one LONWORKS trunk; includes an internal modem. Supports a maximum of 64 devices on the LONWORKS port. Supports one LONWORKS trunk; limited to Basic Access support; and includes an additional RS-232-C serial port for optional external modem. Supports a maximum of 64 devices on the LONWORKS trunks. Supports one LONWORKS trunk; limited to Basic Access support; and includes an internal modem. Supports a maximum of 64 devices on the LONWORKS trunks. 1 Some models are also available in Buy American version (add G after the code number). For repair parts, add -702 after the code number. Table 2: NAE45 Ordering Information MS-NAE45xx-x (Base Features of Each NAE45) MS-NAE4510-2 MS-NAE4510-2U MS-NAE4511-2 MS-NAE4520-2 MS-NAE4521-2 NAE45 Network Automation Engines: Requires a 24 VAC power supply. Each model includes one RS-232-C serial port, one USB serial port, one Ethernet port, and an MS-BAT1020-0 Data Protection Battery. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 100 devices on the N2 Bus or BACnet MS/TP trunk. Supports one BACnet MS/TP (RS-485) trunk; includes an additional RS-232-C serial port for optional external modem; supports a maximum of 100 devices on the BACnet MS/TP trunk. Note: This model is UL Listed, File S4977, UUKL 864-9th Edition Smoke Control Equipment. Also, in order to be UL/ULC compliant, this model must be pre-installed and pre-wired in a standard or custom panel built in the Johnson Controls Reynosa factory. Supports one N2 Bus or BACnet MS/TP (RS-485) trunk; includes an internal modem; supports a maximum of 100 devices on the N2 Bus or BACnet MS/TP trunk. Supports one LONWORKS trunk, includes an additional RS-232-C serial port for optional external modem; supports a maximum of 127 devices on the LONWORKS port. Supports one LONWORKS trunk, includes an internal modem; supports a maximum of 127 devices on the LONWORKS port. 1 Some models are also available in Buy American version (add G after the code number). For repair parts, add -702 after the code number. Table 3: NAE55 Ordering Information MS-NAE55xx-x (Base Features of Each NAE55) MS-NAE5510-2 MS-NAE5510-2U MS-NAE5511-2 MS-NAE5520-2 MS-NAE5521-2 NAE55 Network Automation Engines: Requires a 24 VAC power supply. Each model includes two RS-232-C serial ports, two USB serial ports, two RS-485 ports, one Ethernet port, and one MS-BAT1010-0 Data Protection Battery. Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); supports a maximum of 100 devices on each N2 Bus or BACnet MS/TP trunk. Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); supports a maximum of 100 devices on each N2 Bus or BACnet MS/TP trunk. Note: This model is UL Listed, File S4977, UUKL 864-9th Edition Smoke Control Equipment. Also, in order to be UL/ULC compliant, this model must be pre-installed and pre-wired in a standard or custom panel built in the Johnson Controls Reynosa factory. Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); supports a maximum of 100 devices on each N2 Bus or BACnet MS/TP trunk; includes an internal modem. Supports a LONWORKS trunk, and two N2 Bus trunks or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk). Supports a maximum of 255 devices on the LONWORKS trunk and a maximum of 100 devices on each N2 Bus or BACnet MS/TP trunk. Supports a LONWORKS trunk, and two N2 Bus trunks or two BACnet MS/TP (RS-485) trunks (or one N2 Bus trunk and one BACnet MS/TP trunk); includes an internal modem. Supports a maximum of 255 devices on the LONWORKS trunk and a maximum of 100 devices on each N2 Bus or BACnet MS/TP trunk. 1 Some models are also available in Buy American version (add G after the code number). For the European versions of the NAE55, add an E after the code number. For repair parts, add -702 after the code number. 2

Table 4: NAE85 Ordering Information Product Code Number MS-NIE8500-0 MS-NxE85SW-0 1 MS-NxE85SW-6 1 Rack-mount server preloaded with supported operating system, NxE85 software, and other Metasys system software components; supports up to 10,000 objects. Note: The NAE85 models ship as MS-NIE8500-0 models. Use the Change Model utility in the NxE85 Metasys software to change an NIE85 to an NAE85. New NxE85 software only; for new installations/projects Upgrade NxE85 software; for existing NxE85 engines 1 Standard NxE85 models support 10,000 objects; an expansion upgrade is available to support an additional 15,000 objects. Table 5: NAE Accessories Ordering Information Product Code Number MS-BAT1010-0 MS-BAT1020-0 MS-15KUPG-0 MS-MULTENGSW-6 MS-RAP-0 MS-EXPORT-0 AS-XFR100-1 AS-XFR010-1 SC450RM1U (OEM Part No.) Technical Specifications Table 6: NAE35 and NAE45 Power Requirement Power Consumption Ambient Operating Conditions Ambient Storage Conditions Data Protection Battery Processor Operating System Network and Serial Interfaces Replacement data protection battery for NAE55 and NIE55. Rechargeable gel cell battery: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21 C (70 F) Replacement data protection battery for NAE35, NAE45, and NCE25. Rechargeable NiMH battery: 3.6 V 500 mah, with a typical life of 5 to 7 years at 21 C (70 F) 15,000 object expansion upgrade for NxE85 (only one expansion per NxE85) Contains ToggleTunnel utility for converting an NAE55/NIE55 to an NAE55 model with the N2 Tunneling features enabled. Not for use with MS-NAE5510-1U. Ready Access Portal Server provides a user interface that is a natural, complementary extension of the Metasys Site Management Portal user interface. Note: This option is not necessary for sites that have an ADS/ADX that is the Site Director because Ready Access Portal Server is provided with the ADS/ADX solution. Export Utility extracts historical trend, alarm, and audit data from the system and presents the historical data in a variety of formats. Note: This option is not necessary for sites that have an ADS/ADX that is the Site Director because Export Utility is provided with the ADS/ADX solution. Power transformer (Class 2, 24 VAC, 92 VA maximum output), with enclosure Power transformer (Class 2, 24 VAC, 92 VA maximum output), no enclosure Recommended UPS for NxE85 model: APC Smart-UPS SC 450 VA, 280 W, 120 VAC input/output with NEMA 5-15R output connections Dedicated nominal 24 VAC, Class 2 power supply (North America), safety extra-low voltage (SELV) power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) 25 VA maximum 0 to 50 C (32 122 F); 10 to 90% RH, 30 C (86 F) maximum dew point -40 to 70 C (-40 to 158 F); 5 to 95% RH, 30 C (86 F) maximum dew point Supports data protection on power failure. Rechargeable NiMH battery: 3.6 VDC 500 mah, with a typical life of 5 to 7 years at 21 C (70 F); Product Code Number: MS-BAT1020-0 192 MHz Renesas SH4 7760 RISC processor 128 MB flash nonvolatile memory for operating system, configuration data, and operations data storage and backup128 MB synchronous dynamic random access memory (SDRAM) for operations data dynamic memory Microsoft Windows Embedded CE 6.0 One Ethernet port; connects at 10 or 100 Mbps; 8-pin RJ-45 connector One optically isolated RS-485 port; 9.6k, 19.2k, 38.4k, or 76.8k baud (depending on protocol); with a pluggable and keyed 4-position terminal block (FC Bus available on NAE351x and NAE451x models only) One LONWORKS port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (LONWORKS port available on NAE352x-x and NAE452x models only) One RS-232-C serial port with standard 9-pin sub-d connector that supports standard baud rates. A second serial port, on models without an internal modem, that supports an optional, user-supplied external modem. One USB serial port with standard USB connector that supports an optional, user-supplied external modem. Option: One telephone port for internal modem; up to 56 Kbps; 6-pin modular connector (NAE models with an optional internal modem have one RS-232-C serial port only.) Housing Plastic housing material: ABS polycarbonate UL94-5VB Protection: IP20 (IEC 60529) 3

Table 6: NAE35 and NAE45 Mounting Dimensions (Height x Width x Depth) Shipping Weight Compliance On flat surface with screws on three mounting clips or a single 35 mm DIN rail 131 x 270 x 62 mm (5-3/16 x 10-5/8 x 2-1/2 in.) Minimum space for mounting NAE35 and NAE45: 210 x 350 x 110 mm (8-3/16 x 13-13/16 x 4.-5/16 in.) 1.2 kg (2.7 lb) United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, UL Listed, FIle S4977, UUKL 864-9th Edition, Smoke Control Equipment(MS-NAE35x0-2U and MS-NAE45x0-2U models only) FCC Compliant to CFR47, Part 15, Subpart B, Class A Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment; Industry Canada Compliant, ICES-003 Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant Europe: CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. BACnet International: BACnet Testing Laboratories (BTL) 135-2004 Listed BACnet Building Controller (B-BC) Table 7: NAE55xx-2 Power Requirement Power Consumption Ambient Operating Conditions Ambient Storage Conditions Data Protection Battery Clock Battery Processor Dedicated nominal 24 VAC, Class 2 power supply (North America),SELV power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) 50 VA maximum 0 to 50 C (32 to 122 F); 10 to 90% RH, 30 C (86 F) maximum dew point -40 to 70 C (-40 to 158 F); 5 to 95% RH, 30 C (86 F) maximum dew point Supports data protection on power failure. Rechargeable gel cell battery: 12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21 C (70 F); Product Code Number: MS-BAT1010-0 Maintains real-time clock through a power failure. Onboard cell; typical life 10 years at 21 C (70 F) 1.6 GHz Intel Atom processor 4 GB (2 GB partitioned) flash nonvolatile memory for operating system, configuration data, and operations data storage and backup 1 GB SDRAM for operations data dynamic memory for all models Operating System Network and Serial Interfaces Microsoft Windows Embedded Standard 2009 One Ethernet port; connects at 10 Mbps, 100 Mbps, or 1 Gbps; 8-pin RJ-45 connector Two optically isolated RS-485 ports; 9.6k, 19.2k, 38.4k, or 76.8k baud; pluggable and keyed 4 position terminal blocks (RS-485 ports available on NAE55 models only) Two RS-232-C serial ports, with standard 9-pin sub-d connectors, that support all standard baud rates Two USB serial ports; standard USB connectors support an optional, user-supplied external modem Options: One telephone port for internal modem; up to 56 kbps; 6-pin modular connector One LONWORKS port; FTT10 78 kbps; pluggable, keyed 3-position terminal block (LONWORKS port available on NAE552x-x models only) Housing Plastic housing with internal metal shield Plastic material: ABS + polycarbonate UL94-5VB Protection: IP20 (IEC 60529) Mounting Dimensions (Height x Width x Depth) Shipping Weight Compliance Table 8: NAE85 Turnkey Computer Type Power Requirement Power Supply Ambient Operating Conditions On flat surface with screws on four mounting feet or on dual 35 mm DIN rail 226 x 332 x 96.5 mm (8-7/8 x 13-1/8 x 3-13/16 in.) including mounting feet Minimum space for mounting: 303 x 408 x 148 mm (12 x 16-1/8 x 5-13/16 in.) 2.9 kg (6.4 lb) United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment, FCC Compliant to CFR47, Part 15, Subpart B, Class A Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment, Industry Canada Compliant, ICES-003 Europe: CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant BACnet International: BTL 135-2004 Listed B-BC Dell PowerEdge R420 or latest equivalent 120 240 VAC 50/60 Hz 480 W 10 to 35 C (50 to 95 F); 20 to 80% RH (noncondensing twmax = 29 C) 4

Table 8: NAE85 Turnkey Ambient Storage Conditions Data Protection Processor Hard Disk -40 to 65 C (-40 to 149 F); 5 to 95% RH (noncondensing twmax = 38 C) Recommended Uninterruptible Power Supply (UPS): American Power Conversion (APC ) Smart-UPS SC 450VA, 280 W, 120 VAC input/output, NEMA 5-15R output connections, OEM Part No. SC450RM1U Intel Xeon E5506, 2+ GHz, 4 MB Cache2 or comparable (subject to availability) 2 GB or more, 1066 MHz or higher, 2 x 1 GB, single ranked UDIMMs for 1 processor 2 total (providing ample storage space, size subject to availability) 7.2K RPM Serial Advanced Technology Attachment (SATA), 8.9 cm (3.5 in.) cabled 3 Gbps, RAID 1 configuration with add-in SAS6/iR (SATA/SAS Controller) or higher Internal Optical Drive Operating System Antivirus Software Network and Serial Interfaces DVD ROM, SATA Windows Server 2012 R2 Symantec Endpoint Protection, Small Business Edition (latest version) 2 RJ45 1 Gbps Ethernet Ports, Port 2 is disabled. 2 video ports (1 front, 1 back) 1 9-pin Serial port 4 USB ports (2 front, 2 back) Dimensions (Height x Width x Depth) Mounting Shipping Weight Compliance 4.3 x 43.4 x 62.7 cm (1.7 x 17.1 x 24.7 in.) Mount in an EIA-310D compatible server cabinet 15.9 kg (35 lb) Europe: CE Mark (Record Holder: http://www.dell.com/regulatory_compliance) Table 9: NAE85 Software System Requirements for Installation/Upgrade Product Code Recommended Computer Platform MS-NxE85SW-0: NxE85 software for 10,000 objects (new projects only software) Intel Xeon E5506, 2.13 GHz, 4 MB Cache 2 x 160 GB 7.2K, 8.9 cm (3.5 in.) Cabled 3 Gbps, RAID 1 configuration with add-in SAS6/iR (SATA/SAS Controller) DVD ROM, SATA Hard Disk Supported Operating Systems and Software 2 GB RAM minimum 160 GB minimum Windows Server 2012 R2 Standard and Enterprise Editions Microsoft.NET Framework Version 3.5 Service Pack (SP) 1 Windows Server 2012 Standard and Enterprise Editions Windows Server 2008 R2 Standard and Enterprise Editions with SP1 Windows Server 2008 R2 Web Edition with SP1 Windows Server 2008 Standard and Enterprise Editions (32-bit) with SP2 Network Communication Data Protection Network Interface: Single 1 Gbps Ethernet network interface card connects at 10 Mbps, 100 Mbps or 1 Gbps; (100 Mbps or better recommended) Recommended UPS for NxE85 model: APC Smart-UPS SC 450VA, 280 W, 120 VAC input/output, National Electrical Manufacturers' Association (NEMA) 5-15R output connections, OEM Part No. SC450RM1U 5

Table 9: NAE85 Software System Requirements for Installation/Upgrade Supported Operating Systems for Metasys Client Computers Windows 8.1 or Windows 8.1 Professional Windows 8 or Windows 8 Professional Windows 7 Professional, Enterprise, or Ultimate Edition with SP1 (32-bit or 64-bit) Apple OS X 10.8 Mountain Lion Apple OS X 10.9 Mavericks Required Web Browser Software for Metasys Client Computers Note: Apple Mac operating systems are supported for Metasys client computers only. Windows Internet Explorer version 8, 9, 10, or 11 Note: In Internet Explorer 11, select the option to Display all websites in Compatibility View, found under Tools > Compatibility View Settings, to ensure websites appear and function correctly. (Other browsers, such as Google Chrome and Mozilla Firefox, may also be used but are not fully supported.) Apple Safari version 6.0.5 and 7.0 Note: You use the web browser to download the Launcher application. After you install the Launcher application, you use the Launcher, not the web browser, to log in to Metasys UI. The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys, Panoptix, and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2014 Johnson Controls, Inc. Published in U.S.A. www.johnsoncontrols.com 6