Computer aided error analysis for a threedimensional precision surface mapping system

Size: px
Start display at page:

Download "Computer aided error analysis for a threedimensional precision surface mapping system"

Transcription

1 Computer aided error analysis for a threedimensional precision surface mapping system M. Hill, J.W. McBride, D. Zhang & J. Loh Mechanical Engineering, U~riversity of Southampton, UK Abstract This paper describes the development of a three-dimensional (3-D) non-contact surface mapping system. Both systematic and random sources of error are discussed, including thermal, mechanical and electrical errors. Simulation has been used to model some of these errors. Measurement of calibrated spheres has been adopted for the calibration of the 3-D coordinate measuring system. Several sphere fitting parameters, including radius, sphericity and residual error, are employed as references to judge the errors of 3-D measurement system. Uncertainty in the radius is inspected to evaluate the random error. Deviation of mean radius, sphericity and residual errors are used to estimate the orthogonality between the axes. The technique provides a simple, low-cost method for estimating the errors present in such a measurement system. 1 Introduction Three-dimensional metrology has brought about a significant change in dimensional measurement. It provides more comprehensive and detailed information about geometry than 2-D measurement methods. On the down side, 3- D measurement systems are more complicated in their mechanical structure, error sources and data processing. This paper describes an analysis of the performance of a coordinate measurement system (CMS) in terms of error analysis and calibration. The accuracy of a measuring instrument is determined by many factors, such as the geometric error of the structure, the deformation caused by the movement of the carriage, temperature variations and sensor errors etc. Thus, the quality of the performance of a CMS depends on the assembly and calibration processes. During assembly, key factors include the perpendicularity of each pair of axes and the displacements of driving shafts [l]. Many different methods for the calibration of

2 280 Laser \tetrolog arid Uacl7m Performonce such an instrument have been adopted by researchers, including interferometry and the use of grid plates [2][3]. The 3-D precision non-contact surface mapping system (PSMS) currently being developed at the University of Southampton adopts a laser confocal sensor, which possesses high accuracy, high stability and the ability to measure transparent film [4]. As with any coordinate measurement system, a large number of factors make a significant contribution to the measurement results. An approach has been developed for initial calibration, which involves numerical simulation based on a mathematical model of the system behaviour, referred to as computer aided error analysis and calibration. The aim is to verify the system accuracy and guide the assembly of the system. The approach avoids the need for additional high precision instrumentation. 2 Error sources within the PSMS The PSMS consists of three precision stages, providing movement of a measured sample in the X and Y directions, and the movement of the laser sensor in the vertical axis. The X-axis stage is mounted above the Y-axis stage, which in turn is mounted on the base breadboard. These two stages provide the horizontal motion with encoders having a resolution of up to 0.02pm. A confocal laser sensor is used to measure the Z coordinate of the measured sample over a two-dimensional (2-D) X-Y grid. Based on the structure of this system, the factors affecting the geometric accuracy can be summarised as follow [5]: (i) Errors due to mechanical wear, which introduce unwarranted degrees of freedom, such as lack of straightness and squareness of guides, etc. (ii) Deformation caused by the weight of the structure. (iii) Errors in measuring system, which can be mechanical, thermal or electrical in nature, such as the sensor accuracy, drive system accuracy, stage resolution. (iv) Thermally induced structural changes. Considering the four error sources above, item (i) could lead to orthogonality errors between X- and Y-axis and position errors, item (ii) could induce a tilt error in the Z-axis relative to the XY-plane, whereas items (iii) and (iv) could result in random errors. The observed errors at the probing points of the measurement system can be classified as systematic and random. It is assumed that all errors are random, except for the orthogonality error between the axes which is the most significant systematic error. 3 Theoretical analysis of error calibration Calibrated spheres are widely applied to the calibration of 3-D co-ordinate measurement systems and their probes [6]. In this paper, computer aided error analysis and calibration has been conducted by measuring a calibrated sphere. In the calibration, four parameters are examined to characterise the errors of the measurement system:

3 (i) Deviation of radius: the difference between mean of fitting radius and nonllnal one. (ii) Uncertainty of radius: an index to express the reliability of estimated radius. It can be expressed by the estimated standard deviation. (iii) Sphericity: the radial difference between two concentric spheres that circumscribe and inscribe the form error. It is related to tolerance zone [7]. (iv) Residual error: error after the best-fit sphere is removed. 3.1 Orthogonality error between X and Y axes One potential source of inaccuracy is the orthogonality of the X-Y stage motion. If the X and Y stages are misaligned, the actual measured grid will be skewed as shown in Figure 1. When the measured points from the skewed grid are mapped onto an ideally orthogonal grid, the sphere data will be distorted. In order to investigate the effect of this error, computer simulation is carried out. The simulation assumes that the error of the angle between the X- and Y-axis (referred to as the orthogonality error) is 0 and the calibrated sphere is measured with ths measurement system. Residual error caused by orthogonality error (Q = l") is shown in Figure 2. From this figure, it can be shown that the error is symmetrical about the sphere centre, and that with the increase of scan area (and subsequently the measured segment angle), the amplitude of the residual errors increases. Hence, the following simulations were carried out over various segment angles in order to judge the influence as the measured area increased. Skewed gnd and Square gnd and JIOZ-- " 5 2 actual sphmcal data mapped data 15-~2 Figure 1 : The effect of mapping a Figure 2: Residual error caused by sphere from a skewed grid orthogonality error (B = 1 ") Obviously, thls geometric error causes a deformation of the measured data of a spherical surface. Computer simulated results in Figure 3(a) show that this error causes the deviation of fitting radius from the nominal value. Two more factors: the sphericity and residual error were investigated along with the deviation in the fitting radius. In Figure 3(b) and (c), an almost linear relationship in both sphericity and residual errors can be observed with increasing errors in the orthogonality of the axes and the measured segment angle. The knowledge of the

4 orthogonality error on these three factors will enable prediction of the measurement system behaviour based on experimental results degree --c 1 degree -A- I 5 degree (a) Deviation of radius (b) sphericity (c) residual error Figure 3: Simulation results with different orthogonality error 3.2 Tilt of Z-axis to XY-plane The error caused by the tilt of the Z-axis to the XY-plane (referred to as tilt error) has influences on form measurement of severely curved surfaces, which is much more significant than it is on flat or nearly flat surfaces. Assume that a calibrated sphere is measured under a 3-D CMS with a tilt error of p. Figure 4 illustrates a cross-section of a sphere, which includes the ideal and actual probe direction. When the probe moves from position A to B, the actual displacement should be from B to K. However, with a tilt error of 9, displacement is now taken from B to C. The error induced by the tilt error is given as S z-il it = BC-BK. S can be derived from the geometric relationship in Figure 4, as shown in the following equations. From equation (l), SL-fll, can be shown as a function of angle p and probe position on spherical surface and is illustrated in Figure 5.

5 Figure 4: geometry relationship of tilt Figure 5 : illustration of error on a sphere surface (p = 1 O) y =90 -y, OH = Rtg p + AB OH OC R sin a sin y cos p OH sin a = - cos y, R Rtg y, + AB a = arcsin( cos P R /? =90m-(180 "-a-y)=a-p EC = R sin /? = R sin( a - p) DC EC-AB Rsin(a-p)-AB BC = sin p sin p sin p BK = AF = R - J R ~ - A B ~ R sin( a - p ) - AB 6,_,,,, = BC - BK = - R - J R ~ - A B ~ (1) sin p The influence of the tilt error on sphere measurement has been investigated using simulation. The results in Figure 6 show that the tilt error mainly affects the deviation of radius from its nominal value. It can be seen that as the tilt error increases, the fitting radius deviates more significantly. With the sphericity and residual error shown in Figure 6(b) and (c), the influence of the tilt error is not as apparent as that due to the orthogonality error. The magnitudes of the sphericity and residual error are much smaller when compared to results shown in Figure 3(b) and (c). Similarly, the knowledge gained here will once again be useful in the prediction of the measurement system behaviour.

6 I degree -A- l 5 degree Luser Zletr,ology und Ifuch~ne Performance (a) Deviation of fitting radius (b) Sphericity (c) Residual error Figure 6: Simulation results with different tilt error 3.3 Analysis of Random Error Investigation of random error Figure 7: Residual error Figure 8: Histogram of residual e&r Random errors exist in any measurement system and can be produced by many possible sources of error, as mentioned in section 2. Residual error, after the best fitting sphere has been removed, from the measurements of a mm calibrated sphere (100x 100 grid points) are presented in Figure 7. The histogram

7 Laser \ Ietroiop und \/achrne Per/ormnnt e 285 in Figure 8 shows that the residual error approximates to a normal distribution with a standard deviation of 0.54pm. On this basis, the random error of the system are assumed to be close to a normal distribution Measurement uncertainty Random errors result in an uncertainty in the measurement results. The uncertainty is a strong function of sampling strategy [S]. The sampling strategy can be broken into three components: the size; mode; and the number of points [g]. For sphere measurement, the sampling size corresponds to the measured segment angle. All measurements have been taken using a uniform grid-sampling mode. To investigate the uncertainty of measured radius, simulations were carried out using different segment angles and number of sampling points. Two reference spheres of radii rnm and rnm were used. Results obtained from the two spheres were identical, which suggested that the measurement uncertainty is independent of the radius. The simulations were repeated over 100 times with different measured segment angles and numbers of sampling points. Assuming the standard deviation of the instrumental random error and the fitting radius are o and o~ respectively, the ratio of or/ois known as the error propagation factor [6]. A mathematical description of the relation between o~ and o can be expressed as Equation (2) and referred to f(n, ryl as error propagation factor function: where OR =f(n, 0 (2) n - the line number of sampling grid. W- segment angle of measured sphere segment angle (degree) segment angle 230 (degree) Figure 9: Error propagation coefficient The error propagation coefficients obtained from simulation results are presented in Figure 9, which is approximated by following exponential function: f(n,y)= k,.vk2 (3) where k, and k2 depend on the number of sampling points (nm), which are presented in Figure 10 and approximated by following equations.

8 286 Laser. Iletrolop und \luchine Pe~:for.mance Sampling grid line Sampling grid line Figure 10: Presentation of coefficient kl and k2 From the above analysis, the error propagation coefficient can be used for: Characterisation of the random error of the measurement system By repeatedly measuring a calibration sphere with a fixed segment angle and number of sampling points, calculating the standard deviation of fitting radius, the standard deviation of the random error of the measurement system can be derived by the error propagation function. Determination of the error limit for single measured result If a sphere were measured using a measurement system with known random and negligible systematic error, the standard deviation or error limit of the fitting radius could be determined by the error propagation coefficient function. 4. Evaluation of measurement system error Measurements of a calibrated sphere (r= mm) have been taken on the PSMS. These results were deemed to have included the systematic and random error of the measurement system. Using the results, comparisons can then be made with simulated measurements with assumed errors. The measurements were repeated 50 times, scanning a square area of 3mm and 15x15 data points. The results were presented in Table 1. From the experimental results in Table 1, the mean and standard deviation of the radius estimates indicate that random and systematic errors exist in the measurement system. Assuming that there are only random errors in the measurement system, the standard deviation of random error can be derived from Equation (2) and o = o, l(k,tyk2) = 0.3prn.

9 Table 1 : Example comparisons of measured and simulated results I I Mean I STD of ( Mean / Residual ( Results Experiment r 4 Simulation 1 Radius (mm) Radius (ar) (pm) Sphericity (pm) Error (W) Simulation Simulations were carried out with assumed values of error after detailed analysis of possible error angles. Three example simulations are shown in Table 1. In Simulation 1, the measurement system was simulated with random errors having a standard deviation of 0. 3 but ~ no ~ systematic errors at all. The results obtained were then compared to the actual experimental data. It can be seen in Table 1 that only standard deviation of radius from both experiment and simulation coincides. The three other factors were found to possess significant differences. These differences indicated that systematic errors are likely to be present in the measurement system. Simulation 2 was performed with assumed systematic errors. The orthogonality error was set at 1" with no tilt error in the system. Results from Simulation 2 showed that the standard deviation, sphericity and residual error were found to be similar to the experimental results. However, the mean of radius was still slightly different compared to the experiment. In Section 3.2, it was found that as the tilt error gets larger, the fitting radius deviates more significantly. In both Simulation 1 and 2, no tilt error was included and the mean radius obtained were found to be quite identical. The tilt and orthogonality errors of 1.5" and 1" respectively were thus included in the simulated measurement system. The results obtained from Simulation 3 were found to be close to the measurements taken from the experiment. These results showed that random and systematic errors do exist in the measurement system. On the basis of the simulations the errors are estimated to be as follows: Random error (a) under 0.3 pm Orthogonality error (8) : under 1' Tilt error (p) under 1.5' Work is currently under way to improve the measurement set-up and to verify these error estimates.

10 288 Laser Zletroloe and 2/achrne Performance 5 Conclusion This paper has discussed how the magnitude and nature of errors in an instrumentation system can be estimated from the measurement of a calibration sphere. Using results from simulations, the random and systematic errors in an actual measurement system can be analysed and predicted. This method is simple and easy to realised without any attached instruments. It also provides a basis for the numerical simulation of a CMS based on a mathematical model of system behaviour. References [l] Matsuda, J., Nakaya, T., The Assembly/ Adjustment of coordinate measuring machine and the analysis oferror, Int. J. Japan Soc. Proc. Eng., Vol. 25 No.2 pplll [2] Zhang, G., Error compensation of coordinate measurement machines, Annals of the CIRP, Vol. 34, pp , [3] Zhang, G., Fu, J., A method for optical CMM calibration using a grid plate, Annals of the CIRP Vol49, pp , [4] McBride, J., Hill, M., Loh, J., Sensitivity ofa 3-0 surfice mapping system to environmental perturbation, To be published in LAMDAMAP, [S] Burdekin, M., Voutsadopoulos, C., Computer aided calibration of the geometric errors of multi-axis coordinate measuring machines, Proc Instn, Mech Engrs Vol 195, pp , 1981 [6] Bourdet, P., Lartigue, C., and Leveaux, F, effects ofdata point distribution and mathematical model on finding the best-fit sphere to data, Precision Engineering, Vol. 15, No.3, pp , July, [7] Kanada,T., Evaluation of spherical form errors-comptctation of sphericity by means of minimum zone method and some examinations with using simulated data, Precision Engineering, Vol. 17, pp28 l-289,1995. [8] Phillips, S.D., Borchardt, B. Estler W.T., and Buttress, J., The estimation of measurement uncertainty of small circular features measured by coordinate measuring machines, Precision engineering, Vol., 22, pp87-97,1998. [9] Choi, W., Kerfess, T., Jonathan C., Sampling uncertainty in coordinate measuring data analysis, Precision Engineering, Vol. 22, pp , 1998.

Form evaluation algorithms in coordinate metrology

Form evaluation algorithms in coordinate metrology Form evaluation algorithms in coordinate metrology D. Zhang, M. Hill, J. McBride & J. Loh Mechanical Engineering, University of Southampton, United Kingdom Abstract Form evaluation algorithms that characterise

More information

Abstract. Introduction

Abstract. Introduction The efficient calculation of the Cartesian geometry of non-cartesian structures J.M. Freeman and D.G. Ford Engineering Control and Metrology Research Group, The School of Engineering, University of Huddersfield.

More information

Investigating the volumetric performance of multi-axis measurement arms

Investigating the volumetric performance of multi-axis measurement arms Investigating the volumetric performance of multi-axis measurement arms J.Singh, M.Hughes & J N Petzing Wolfson School of Mechanical & Manufacturing Engineering Loughborough Universty, UK Abstract Multi-axis

More information

Assessment of the volumetric accuracy of a machine with geometric compensation

Assessment of the volumetric accuracy of a machine with geometric compensation Assessment of the volumetric accuracy of a machine with geometric compensation A.P. Longstaff, S.R. Postlethwaite & D.G. Ford Precision Engineering Centre, University of HuddersJield, England Abstract

More information

METHODS FOR PERFORMANCE EVALUATION OF SINGLE AXIS POSITIONING SYSTEMS: POINT REPEATABILITY

METHODS FOR PERFORMANCE EVALUATION OF SINGLE AXIS POSITIONING SYSTEMS: POINT REPEATABILITY METHODS FOR PERFORMANCE EVALUATION OF SINGLE AXIS POSITIONING SYSTEMS: POINT REPEATABILITY Nathan Brown 1 and Ronnie Fesperman 2 1 ALIO Industries. Wheat Ridge, CO, USA 2 National Institute of Standards

More information

Test Piece for 5-axis Machining Centers

Test Piece for 5-axis Machining Centers Test Piece for 5-axis Machining Centers S. Bossoni, W. Knapp, K. Wegener Institute of Machine Tools and Manufacturing, ETH Zurich, Switzerland, and inspire AG für mechatronische Produktionssysteme und

More information

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE I IMEKO World Congress Fundamental and Applied Metrology September 6, 9, Lisbon, Portugal COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER

More information

OUT OF MACHINE CALIBRATION TECHNIQUE FOR ANALOG PROBES

OUT OF MACHINE CALIBRATION TECHNIQUE FOR ANALOG PROBES XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil OUT OF MACHINE CALIBRATION TECHNIQUE FOR ANALOG PROBES J.J. Aguilar 1, J.A. Yagüe 1, J.A.

More information

good check of volumetric accuracy. However, if the mea error components. However, if the errors measured are large,

good check of volumetric accuracy. However, if the mea error components. However, if the errors measured are large, REVIEW OF SCIENTIFIC INSTRUMENTS VOLUME 71, NUMBER 10 OCTOBER 2000 Laser vector measurement technique for the determination and compensation of volumetric positioning errors. Part I: Basic theory Charles

More information

A practical system for 5-axis volumetric compensation

A practical system for 5-axis volumetric compensation A practical system for 5-axis volumetric compensation S.R. Postlethwaite, D.G. Ford 7%e School of Engineering, The University ofhuddersfield, Oueensgate, Huddersfield, HD1 3DH, England Email: s.r.postlethwaite@hud.ac.uk

More information

UNIT IV - Laser and advances in Metrology 2 MARKS

UNIT IV - Laser and advances in Metrology 2 MARKS UNIT IV - Laser and advances in Metrology 2 MARKS 81. What is interferometer? Interferometer is optical instruments used for measuring flatness and determining the lengths of slip gauges by direct reference

More information

RELIABILITY OF PARAMETRIC ERROR ON CALIBRATION OF CMM

RELIABILITY OF PARAMETRIC ERROR ON CALIBRATION OF CMM RELIABILITY OF PARAMETRIC ERROR ON CALIBRATION OF CMM M. Abbe 1, K. Takamasu 2 and S. Ozono 2 1 Mitutoyo Corporation, 1-2-1, Sakato, Takatsu, Kawasaki, 213-12, Japan 2 The University of Tokyo, 7-3-1, Hongo,

More information

NUMERICAL METHOD TO ESTIMATE TOLERANCES COMBINED EFFECTS ON A MECHANICAL SYSTEM

NUMERICAL METHOD TO ESTIMATE TOLERANCES COMBINED EFFECTS ON A MECHANICAL SYSTEM INTERNATIONAL DESIGN CONFERENCE - DESIGN 2004 Dubrovnik, May 18-21, 2004. NUMERICAL METHOD TO ESTIMATE TOLERANCES COMBINED EFFECTS ON A MECHANICAL SYSTEM D. Cambiaghi, A. Magalinia and D. Vetturi Keywords:

More information

University of Huddersfield Repository

University of Huddersfield Repository University of Huddersfield Repository Li, Duo, Ding, Fei, Jiang, Xiangqian, Blunt, Liam A. and Tong, Zhen Calibration of an interferometric surface measurement system on an ultra precision turning lathe

More information

Determining the 5-axes machine tool contouring performance with dynamic R-test measurements

Determining the 5-axes machine tool contouring performance with dynamic R-test measurements Determining the 5-axes machine tool contouring performance with dynamic R-test measurements H.A.M. Spaan 1, G.H.J. Florussen 1 1 IBS Precision Engineering, the Netherlands spaan@ibspe.com Abstract Current

More information

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION C. Schwalm, DESY, Hamburg, Germany Abstract For the Alignment of the European XFEL, a Straight Line Reference System will be used

More information

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty Good Practice guide to measure roundness on roller machines and to estimate their uncertainty Björn Hemming, VTT Technical Research Centre of Finland Ltd, Finland Thomas Widmaier, Aalto University School

More information

INSPECTION OF THE TURBINE BLADES USING SCANNING TECHNIQUES

INSPECTION OF THE TURBINE BLADES USING SCANNING TECHNIQUES INSPECTION OF THE TURBINE BLADES USING SCANNING TECHNIQUES H. Nieciag, M. Traczynski and Z. Chuchro Department of Geometrical Quanities Metrology The Institute of Metal Cutting, 30-011 Cracow, Poland Abstract:

More information

Transactions on Engineering Sciences vol 16, 1997 WIT Press, ISSN

Transactions on Engineering Sciences vol 16, 1997 WIT Press,   ISSN Laser computer calibration and quality assurance of certain kinematics and geometrical parameters A. Ryniewicz and J. Gawlik Cracow University of Technology, ALJana Pawla II nr 37, 31-864 TOWTOfP; fol47vd

More information

MULTIPLE-SENSOR INTEGRATION FOR EFFICIENT REVERSE ENGINEERING OF GEOMETRY

MULTIPLE-SENSOR INTEGRATION FOR EFFICIENT REVERSE ENGINEERING OF GEOMETRY Proceedings of the 11 th International Conference on Manufacturing Research (ICMR2013) MULTIPLE-SENSOR INTEGRATION FOR EFFICIENT REVERSE ENGINEERING OF GEOMETRY Feng Li, Andrew Longstaff, Simon Fletcher,

More information

LOCAL AND GLOBAL CALIBRATION OF COORDINATE MEASURING MACHINES

LOCAL AND GLOBAL CALIBRATION OF COORDINATE MEASURING MACHINES LOCAL AND GLOBAL CALIBRATION OF COORDINATE MEASURING MACHINES S.D. ANTUNES AND P.M.V.C.D. ANTUNES Instituto Superior Técnico, Avª Rovisco Pais, 1049-001 Lisboa, PORTUGAL E-mail: santunes@ist.utl.pt, pantunes@mail.ipq.pt

More information

Laser diagonal testing

Laser diagonal testing Laser diagonal testing H-5650-2056-01-B 20/08/2018 1 Introduction This presentation explains how Renishaw laser calibration systems can be used to check machine positioning performance along machine diagonals,

More information

ACTA TECHNICA CORVINIENSIS Bulletin of Engineering Tome X [2017] Fascicule 2 [April June] ISSN:

ACTA TECHNICA CORVINIENSIS Bulletin of Engineering Tome X [2017] Fascicule 2 [April June] ISSN: Tome X [2017] Fascicule 2 [April June] ISSN: 2067 3809 1. Yung-Cheng WANG, 2. Bean-Yin LEE, 1. Chih-Hao HUANG, 3. Chi-Hsiang CHEN DEVELOPMENT OF THE AXIAL PRECISION INSPECTION SYSTEM FOR SPINDLES IN TOOL

More information

COMPARISON OF TWO INSTRUMENT DESIGNS FOR NON-CONTACT MEASUREMENT OF GOSSAMER MIRRORS

COMPARISON OF TWO INSTRUMENT DESIGNS FOR NON-CONTACT MEASUREMENT OF GOSSAMER MIRRORS COMPARISON OF TWO INSTRUMENT DESIGNS FOR NON-CONTACT MEASUREMENT OF GOSSAMER MIRRORS Phil Smith and R. Ryan Vallance Precision Systems Laboratory, University of Kentucky * Abstract Lightweight, large format

More information

GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY

GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY Manfred Juretzko and Eva Richter Geodätisches Institut Universität Karlruhe Email: juretzko@gik.uni-karlsruhe.de Abstract:

More information

Introduction to Metrology. ME 338: Manufacturing Processes II Instructor: Ramesh Singh; Notes: Profs. Singh/Melkote/Colton

Introduction to Metrology. ME 338: Manufacturing Processes II Instructor: Ramesh Singh; Notes: Profs. Singh/Melkote/Colton Introduction to Metrology 1 Metrology-Science of Measurement What do we usually measure Time Space Flow Mass/weight/force In this topic we will measure Geometry Quality Surface finish Singh/Kurfess/Joshi

More information

ksa MOS Ultra-Scan Performance Test Data

ksa MOS Ultra-Scan Performance Test Data ksa MOS Ultra-Scan Performance Test Data Introduction: ksa MOS Ultra Scan 200mm Patterned Silicon Wafers The ksa MOS Ultra Scan is a flexible, highresolution scanning curvature and tilt-measurement system.

More information

DESIGN AND VERIFICATION OF THE TRINANO ULTRA PRECISION CMM

DESIGN AND VERIFICATION OF THE TRINANO ULTRA PRECISION CMM URN (Paper): urn:nbn:de:gbv:ilm1-2011iwk-092:8 56 TH INTERNATIONAL SCIENTIFIC COLLOQUIUM Ilmenau University of Technology, 12 16 September 2011 URN: urn:nbn:gbv:ilm1-2011iwk:5 DESIGN AND VERIFICATION OF

More information

Uncertainty simulator to evaluate the electrical and mechanical deviations in cylindrical near field antenna measurement systems

Uncertainty simulator to evaluate the electrical and mechanical deviations in cylindrical near field antenna measurement systems Uncertainty simulator to evaluate the electrical and mechanical deviations in cylindrical near field antenna measurement systems S. Burgos*, F. Martín, M. Sierra-Castañer, J.L. Besada Grupo de Radiación,

More information

What makes Bolt Self-loosening Predictable?

What makes Bolt Self-loosening Predictable? What makes Bolt Self-loosening Predictable? Abstract Dr.-Ing. R. Helfrich, Dr.-Ing. M. Klein (INTES GmbH, Germany) In mechanical engineering, bolts are frequently used as standard fastening elements, which

More information

XL-80 spares list. Application note. Overview

XL-80 spares list. Application note. Overview XL-80 spares list Overview This application note lists the system components for the XL-80 laser system. To order please contact your local Renishaw office at www.renishaw.com/contact Description XL-80

More information

Testing spherical surfaces: a fast, quasi-absolute technique

Testing spherical surfaces: a fast, quasi-absolute technique Testing spherical surfaces: a fast, quasi-absolute technique Katherine Creath and James C. Wyant A technique for measuring the quality of spherical surfaces that provides a quasi-absolute result is presented.

More information

ND 1202 ND 1203 ND monochrome flat-panel display for position values, dialogs and inputs, graphics functions and soft keys

ND 1202 ND 1203 ND monochrome flat-panel display for position values, dialogs and inputs, graphics functions and soft keys ND 1202 ND 1203 ND 1204 Axes* 2 (XY) 3 (XYQ) or 3 (XYZ) 4 (XYZQ) Encoder inputs*» 1 V PP or «TTL (other interfaces upon request) Subdivision factor 10-fold (only for 1 V PP ) Display step 1) Display Functions

More information

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt) Laser radiations Laser radiations Laser radiations Laser radiations Length Length Frequency stabilized laser (He- Ne): vacuum wavelength Frequency stabilized laser (He- Ne): absolute frequency Frequency

More information

Measurements using three-dimensional product imaging

Measurements using three-dimensional product imaging ARCHIVES of FOUNDRY ENGINEERING Published quarterly as the organ of the Foundry Commission of the Polish Academy of Sciences ISSN (1897-3310) Volume 10 Special Issue 3/2010 41 46 7/3 Measurements using

More information

High Precision Lens Mounting

High Precision Lens Mounting High Precision Lens Mounting APOMA Tucson Tech Workshop, 10-11 November, 2016 Presentation by Frédéric Lamontagne Institut national d optique (INO) Québec City, Canada 2016 Outline 1. Review of common

More information

Jinying. factors to. proposed. Introduction. Error element. solutions. same time, Figure

Jinying. factors to. proposed. Introduction. Error element. solutions. same time, Figure International Conference on Applied Science and Engineering Innovation (ASEI 2015) Error element analysis and detection for BV755 CNC milling machine based on Ball-bar Jinying Chen 1, Xiaotie Niu 2, Lijuan

More information

Using surface markings to enhance accuracy and stability of object perception in graphic displays

Using surface markings to enhance accuracy and stability of object perception in graphic displays Using surface markings to enhance accuracy and stability of object perception in graphic displays Roger A. Browse a,b, James C. Rodger a, and Robert A. Adderley a a Department of Computing and Information

More information

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke*

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke* ADS40 Calibration & Verification Process Udo Tempelmann*, Ludger Hinsken**, Utz Recke* *Leica Geosystems GIS & Mapping GmbH, Switzerland **Ludger Hinsken, Author of ORIMA, Konstanz, Germany Keywords: ADS40,

More information

Modelling of a Wall Inlet in Numerical Simulation of Airflow in Livestock Buildings

Modelling of a Wall Inlet in Numerical Simulation of Airflow in Livestock Buildings 1 Modelling of a Wall Inlet in Numerical Simulation of Airflow in Livestock Buildings B. Bjerg 1, K. Svidt 2, S Morsing 3, G. Zhang 3 and J. O. Johnsen 3 1 The Royal Veterinary and Agricultural University,

More information

UNITEST - A new device for the static and dynamic testing of unconventional machine structures

UNITEST - A new device for the static and dynamic testing of unconventional machine structures UNITEST - A new device for the static and dynamic testing of unconventional machine structures K.E. Meitz Department of Production Engineering, Technical University Graz, Kopernikusgasse 24, A-8010 Graz,

More information

ENGINEERING MEASUREMENTS ENTERPRISE LTD. TECHNICAL REPORT RESULTS OF DEVIATION MEASUREMENTS AND GEOMETRY OF ROTARY KILN GEOCEMENT PLANT

ENGINEERING MEASUREMENTS ENTERPRISE LTD. TECHNICAL REPORT RESULTS OF DEVIATION MEASUREMENTS AND GEOMETRY OF ROTARY KILN GEOCEMENT PLANT GEOSERVEX s.c. Zbigniew i Boleslaw Krystowczyk e-mail: office@geoservex.com.pl http://www.geoservex.com.pl office: ul. Kościuszki /19A 8-9 Bydgoszcz, POLAND tel: (+48) 34 6 fax: (+48) 34 6 EU VAT ID No:

More information

PARAMETERS INFLUENCING THE PRECISION OF SLM PRODUCTION

PARAMETERS INFLUENCING THE PRECISION OF SLM PRODUCTION PARAMETERS INFLUENCING THE PRECISION OF SLM PRODUCTION PETR KELLER, RADOMIR MENDRICKY Department of Manufacturing Systems and Automation, Technical University of Liberec, Liberec, Czech Republic DOI: 10.17973/MMSJ.2015_10_201540

More information

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Wenjuan Sun and Stephen Brown 10 th May 2016 1 Possible factors influencing XCT measurements Components Influencing variables Possible

More information

Journal of Advanced Mechanical Design, Systems, and Manufacturing

Journal of Advanced Mechanical Design, Systems, and Manufacturing A Study on Error Compensation on High Precision Machine Tool System Using a 2D Laser Holographic Scale System* (First Report: Scale Development and Two Dimensional Motion Error Compensation Method) Toru

More information

Condenser Optics for Dark Field X-Ray Microscopy

Condenser Optics for Dark Field X-Ray Microscopy Condenser Optics for Dark Field X-Ray Microscopy S. J. Pfauntsch, A. G. Michette, C. J. Buckley Centre for X-Ray Science, Department of Physics, King s College London, Strand, London WC2R 2LS, UK Abstract.

More information

A STUDY OF GEODETIC GRIDS FOR THE CONTINUOUS, QUASI REAL TIME ALIGNMENT OF THE ATLAS SEMICONDUCTOR TRACKER

A STUDY OF GEODETIC GRIDS FOR THE CONTINUOUS, QUASI REAL TIME ALIGNMENT OF THE ATLAS SEMICONDUCTOR TRACKER A STUDY OF GEODETIC GRIDS FOR THE CONTINUOUS, QUASI REAL TIME ALIGNMENT OF THE ATLAS SEMICONDUCTOR TRACKER S. M. Gibson, P. A. Coe, A. Mitra, D. F. Howell, R. B. Nickerson ATLAS Group, Particle Physics,

More information

A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES

A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES Andre R. Sousa 1 ; Armando Albertazzi 2 ; Alex Dal Pont 3 CEFET/SC Federal Center for Technological Education of Sta. Catarina

More information

Exterior Orientation Parameters

Exterior Orientation Parameters Exterior Orientation Parameters PERS 12/2001 pp 1321-1332 Karsten Jacobsen, Institute for Photogrammetry and GeoInformation, University of Hannover, Germany The georeference of any photogrammetric product

More information

TEST METHODS FOR COORDINATED MOTION OF FIVE-AXIS MACHINING CENTERS

TEST METHODS FOR COORDINATED MOTION OF FIVE-AXIS MACHINING CENTERS TEST METHODS FOR COORDINATED MOTION OF FIVE-AXIS MACHINING CENTERS Shawn P. Moylan, Ronnie R. Fesperman, and M. Alkan Donmez Manufacturing Engineering Laboratories National Institute of Standards and Technology

More information

Error Budget as a Design Tool For Ultra-Precision Diamond Turning Machines Form Errors

Error Budget as a Design Tool For Ultra-Precision Diamond Turning Machines Form Errors Error Budget as a Design Tool For Ultra-Precision Diamond Turning Machines Form Errors Mark Walter, Bruce Norlund, Robert Koning, Jeff Roblee, Precitech, Inc. Keene, NH 3431 USA Abstract This paper describes

More information

Chapters 1 7: Overview

Chapters 1 7: Overview Chapters 1 7: Overview Chapter 1: Introduction Chapters 2 4: Data acquisition Chapters 5 7: Data manipulation Chapter 5: Vertical imagery Chapter 6: Image coordinate measurements and refinements Chapter

More information

Rectangular Coordinates in Space

Rectangular Coordinates in Space Rectangular Coordinates in Space Philippe B. Laval KSU Today Philippe B. Laval (KSU) Rectangular Coordinates in Space Today 1 / 11 Introduction We quickly review one and two-dimensional spaces and then

More information

COMPACT RANGE CALIBRATION AND ALIGNMENT

COMPACT RANGE CALIBRATION AND ALIGNMENT COMPACT RANGE CALIBRATION AND ALIGNMENT M. Juretzko and E. Richter Geodetic Institute, University of Karlsruhe, 76128 Karlsruhe, Germany juretzko@gik.uni-karlsruhe.de richter@gik.uni-karlsruhe.de M. Paquay

More information

The development of a laser array measurement system for three dimensional positioning testing in machine tool

The development of a laser array measurement system for three dimensional positioning testing in machine tool The development of a laser array measurement system for three dimensional ing testing in machine tool Wenyuh Jywe 1, Fong-Zhi Chen 2, Chun-Jen Chen 2, Hsin Hong Jwo 1, Jhih-Ming Pan 1 1 National Formosa

More information

IMECE FUNCTIONAL INTERFACE-BASED ASSEMBLY MODELING

IMECE FUNCTIONAL INTERFACE-BASED ASSEMBLY MODELING Proceedings of IMECE2005 2005 ASME International Mechanical Engineering Congress and Exposition November 5-11, 2005, Orlando, Florida USA IMECE2005-79945 FUNCTIONAL INTERFACE-BASED ASSEMBLY MODELING James

More information

Development of CNC machine performance standards

Development of CNC machine performance standards Development of CNC machine performance standards D.M.S. Blackshaw, V. Chiles, D. Jenkinson School of Engineering, University of Northumbria, Newcastle upon Tyne, NE1 8ST vie. chiles@unn. ac. uk Abstract

More information

Analyses of direct verification data of Rockwell diamond indenters by iterative regression method

Analyses of direct verification data of Rockwell diamond indenters by iterative regression method ACTA IMEKO September 24, Volume 3, Number 3, 5 2 www.imeko.org Analyses of direct verification data of Rockwell diamond indenters by iterative regression method Satoshi Takagi National Metrology Institute

More information

A NON-IMAGING OPTICAL SYSTEM FOR CHARACTERISATION OF BALL- SHAPED MICRO-INDENTERS

A NON-IMAGING OPTICAL SYSTEM FOR CHARACTERISATION OF BALL- SHAPED MICRO-INDENTERS IMEKO 22 nd TC3, 12 th TC5 and 3 rd TC22 International Conferences 3 to 5 February, 2014, Cape Town, Republic of South Africa A NON-IMAGING OPTICAL SYSTEM FOR CHARACTERISATION OF BALL- SHAPED MICRO-INDENTERS

More information

Mirror selection for optical periscopes

Mirror selection for optical periscopes Mirror selection for optical periscopes Overview Renishaw differential interferometer detector head (RLD10-X3-DI) is sometimes required to work with larger beam separation between the measurement and reference

More information

APPLICATIONS FOR COORDINATED MOTION IN RADOME TESTING

APPLICATIONS FOR COORDINATED MOTION IN RADOME TESTING APPLICATIONS FOR COORDINATED MOTION IN RADOME TESTING Scott McBride Evan Langman Marion Baggett MI Technologies, LLC 4500 River Green Parkway, Suite 200 Duluth, GA 30096 ABSTRACT Traditional data collection

More information

Fast scanning method for one-dimensional surface profile measurement by detecting angular deflection of a laser beam

Fast scanning method for one-dimensional surface profile measurement by detecting angular deflection of a laser beam Fast scanning method for one-dimensional surface profile measurement by detecting angular deflection of a laser beam Ryo Shinozaki, Osami Sasaki, and Takamasa Suzuki A fast scanning method for one-dimensional

More information

Abstract. Introduction

Abstract. Introduction The analysis of geometrical and thermal errors of non-cartesian structures J.M. Freeman and D.G. Ford Engineering Control and Metrology Research Group, The School ofengineering, University of Huddersfield.

More information

Using three-dimensional CURVIC contact models to predict stress concentration effects in an axisymmetric model

Using three-dimensional CURVIC contact models to predict stress concentration effects in an axisymmetric model Boundary Elements XXVII 245 Using three-dimensional CURVIC contact models to predict stress concentration effects in an axisymmetric model J. J. Rencis & S. R. Pisani Department of Mechanical Engineering,

More information

Improving dimensional accuracy by error modelling and its compensation for 3-axis Vertical Machining Centre

Improving dimensional accuracy by error modelling and its compensation for 3-axis Vertical Machining Centre Improving dimensional accuracy by error modelling and its compensation for 3-axis Vertical Machining Centre H M Dobariya, Y D Patel 2, D A Jani 3 Abstract In today s era, machining centres are very important

More information

Manufacturing Signatures and CMM Sampling Strategies

Manufacturing Signatures and CMM Sampling Strategies Manufacturing Signatures and CMM Sampling Strategies Giovanni Moroni**, Wilma Polini*, Marco Rasella** **Dipartimento di Meccanica, Politecnico di Milano, piazzale Leonardo da Vinci 32, Milano, 20133,

More information

USING A TRACKING LASER INTERFEROMETER TO CHARACTERIZE THE PLANARITY OF A PLANAR NEAR-FIELD SCANNER

USING A TRACKING LASER INTERFEROMETER TO CHARACTERIZE THE PLANARITY OF A PLANAR NEAR-FIELD SCANNER USING A TRACKING LASER INTERFEROMETER TO CHARACTERIZE THE PLANARITY OF A PLANAR NEAR-FIELD SCANNER Paul R. Rousseau, William C. Wysock, and Carlos M. Turano The Aerospace Corporation P.O. Box 92957, Mail

More information

GEMINI 8-M Telescopes Project

GEMINI 8-M Telescopes Project GEMINI 8-M Telescopes Project TN-O-G0003 Effects on Surface Figure Due to Random Error in Support Actuator Forces for an 8-m Primary Mirror Myung K. Cho Optics Group February 22, 1993 ABSTRACT The effects

More information

Accuracy for CMMs and Machine Tools

Accuracy for CMMs and Machine Tools Systematic machine errors Rapid Calibration and Compensation of CMM and Machine ools: Recent Developments of the Lasertracer echnology Motivation Geometry errors he LaserRACER RAC-CAL for Error Mapping

More information

CALCULATION OF 3-D ROUGHNESS MEASUREMENT UNCERTAINTY WITH VIRTUAL SURFACES. Michel Morel and Han Haitjema

CALCULATION OF 3-D ROUGHNESS MEASUREMENT UNCERTAINTY WITH VIRTUAL SURFACES. Michel Morel and Han Haitjema CALCULATION OF 3-D ROUGHNESS MEASUREMENT UNCERTAINTY WITH VIRTUAL SURFACES Michel Morel and Han Haitjema Eindhoven University of Technology Precision Engineering section P.O. Box 513 W-hoog 2.107 5600

More information

Ch 22 Inspection Technologies

Ch 22 Inspection Technologies Ch 22 Inspection Technologies Sections: 1. Inspection Metrology 2. Contact vs. Noncontact Inspection Techniques 3. Conventional Measuring and Gaging Techniques 4. Coordinate Measuring Machines 5. Surface

More information

Aberrations in Holography

Aberrations in Holography Aberrations in Holography D Padiyar, J Padiyar 1070 Commerce St suite A, San Marcos, CA 92078 dinesh@triple-take.com joy@triple-take.com Abstract. The Seidel aberrations are described as they apply to

More information

Review of paper Non-image-forming optical components by P. R. Yoder Jr.

Review of paper Non-image-forming optical components by P. R. Yoder Jr. Review of paper Non-image-forming optical components by P. R. Yoder Jr. Proc. of SPIE Vol. 0531, Geometrical Optics, ed. Fischer, Price, Smith (Jan 1985) Karlton Crabtree Opti 521 14. November 2007 Introduction:

More information

PROBE RADIUS COMPENSATION AND FITTING ERRORS IN CAD-BASED MEASUREMENTS OF FREE-FORM SURFACE: A CASE STUDY

PROBE RADIUS COMPENSATION AND FITTING ERRORS IN CAD-BASED MEASUREMENTS OF FREE-FORM SURFACE: A CASE STUDY XIX IMEKO World Congress Fundamental and Applied Metrology September 11, 9, Lisbon, Portugal PROBE RADIUS COMPENSATION AND FITTING ERRORS IN CAD-BASED MEASUREMENTS OF FREE-FORM SURFACE: A CASE STUDY Malgorzata

More information

SWING ARM OPTICAL CMM

SWING ARM OPTICAL CMM SWING ARM OPTICAL CMM Peng Su, Chang Jin Oh, Robert E. Parks, James H. Burge College of Optical Sciences University of Arizona, Tucson, AZ 85721 OVERVIEW The swing arm profilometer described in reference

More information

Cutting Force Simulation of Machining with Nose Radius Tools

Cutting Force Simulation of Machining with Nose Radius Tools International Conference on Smart Manufacturing Application April. 9-11, 8 in KINTEX, Gyeonggi-do, Korea Cutting Force Simulation of Machining with Nose Radius Tools B. Moetakef Imani 1 and N. Z.Yussefian

More information

Simulation of rotation and scaling algorithm for numerically modelled structures

Simulation of rotation and scaling algorithm for numerically modelled structures IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Simulation of rotation and scaling algorithm for numerically modelled structures To cite this article: S K Ruhit et al 2018 IOP

More information

7 Fractions. Number Sense and Numeration Measurement Geometry and Spatial Sense Patterning and Algebra Data Management and Probability

7 Fractions. Number Sense and Numeration Measurement Geometry and Spatial Sense Patterning and Algebra Data Management and Probability 7 Fractions GRADE 7 FRACTIONS continue to develop proficiency by using fractions in mental strategies and in selecting and justifying use; develop proficiency in adding and subtracting simple fractions;

More information

Determination and compensation of the reference surface from redundant sets of surface measurements

Determination and compensation of the reference surface from redundant sets of surface measurements Determination and compensation of the reference surface from redundant sets of surface measurements François Polack and Muriel Thomasset Synchrotron SOLEIL, Saint-Aubin, FRANCE IWXM 4, Barcelona July 212

More information

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems 501, 502 1051, 1052, 1054 1601, 1602, 1604 1602UC 1052UC 501HC Precision Measurement Systems 501, 502 1051, 1052, 1054 1601, 1602, 1604 Excel 501 HM/HC Excel 502 HM/HC Excel 501 Excel 502 Scale Resolution

More information

INFLUENCE OF CURVATURE ILLUMINATION WAVEFRONT IN QUANTITATIVE SHEAROGRAPHY NDT MEASUREMENT

INFLUENCE OF CURVATURE ILLUMINATION WAVEFRONT IN QUANTITATIVE SHEAROGRAPHY NDT MEASUREMENT 1 th A-PCNDT 6 Asia-Pacific Conference on NDT, 5 th 1 th Nov 6, Auckland, New Zealand INFLUENCE OF CURVATURE ILLUMINATION WAVEFRONT IN QUANTITATIVE SHEAROGRAPHY NDT MEASUREMENT Wan Saffiey Wan Abdullah

More information

NEW MONITORING TECHNIQUES ON THE DETERMINATION OF STRUCTURE DEFORMATIONS

NEW MONITORING TECHNIQUES ON THE DETERMINATION OF STRUCTURE DEFORMATIONS Proceedings, 11 th FIG Symposium on Deformation Measurements, Santorini, Greece, 003. NEW MONITORING TECHNIQUES ON THE DETERMINATION OF STRUCTURE DEFORMATIONS D.Stathas, O.Arabatzi, S.Dogouris, G.Piniotis,

More information

17. SEISMIC ANALYSIS MODELING TO SATISFY BUILDING CODES

17. SEISMIC ANALYSIS MODELING TO SATISFY BUILDING CODES 17. SEISMIC ANALYSIS MODELING TO SATISFY BUILDING CODES The Current Building Codes Use the Terminology: Principal Direction without a Unique Definition 17.1 INTRODUCTION { XE "Building Codes" }Currently

More information

Research on error detection technology of numerical control machine tool. Cao YongJie

Research on error detection technology of numerical control machine tool. Cao YongJie Joint International Mechanical, Electronic and Information Technology Conference (JIMET 2015) Research on error detection technology of numerical control machine tool Cao YongJie Shanghai University of

More information

Application of a FEA Model for Conformability Calculation of Tip Seal in Compressor

Application of a FEA Model for Conformability Calculation of Tip Seal in Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Application of a FEA Model for Conformability Calculation of Tip Seal in Compressor

More information

A Multisensor Approach for Error Compensation in CNC Machine Tools

A Multisensor Approach for Error Compensation in CNC Machine Tools Journal of Automation and Control Engineering Vol. 1, No. 3, September 213 A Multisensor Approach for Error Compensation in CNC Machine Tools Abderrazak El Ouafi and Noureddine Barka University of Quebec

More information

PATCH TEST OF HEXAHEDRAL ELEMENT

PATCH TEST OF HEXAHEDRAL ELEMENT Annual Report of ADVENTURE Project ADV-99- (999) PATCH TEST OF HEXAHEDRAL ELEMENT Yoshikazu ISHIHARA * and Hirohisa NOGUCHI * * Mitsubishi Research Institute, Inc. e-mail: y-ishi@mri.co.jp * Department

More information

BEST-FIT ADJUSTMENTS OF THE REFLECTORS IN A COMPACT RANGE 1

BEST-FIT ADJUSTMENTS OF THE REFLECTORS IN A COMPACT RANGE 1 Paper to be presented at Antenna Measurement Techniques Association 31 st Annual Symposium (AMTA 2009), Salt Lake City, Utah, USA, 1-6 November 2009. BEST-FIT ADJUSTMENTS OF THE REFLECTORS IN A COMPACT

More information

ENGR142 PHYS 115 Geometrical Optics and Lenses

ENGR142 PHYS 115 Geometrical Optics and Lenses ENGR142 PHYS 115 Geometrical Optics and Lenses Part A: Rays of Light Part B: Lenses: Objects, Images, Aberration References Pre-lab reading Serway and Jewett, Chapters 35 and 36. Introduction Optics play

More information

IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS

IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS VÍT ZELENÝ, IVANA LINKEOVÁ, PAVEL SKALNÍK (LENGTH MEASUREMENT DEPARTMENT) 5th November 2014

More information

SUPPORTING LINEAR MOTION: A COMPLETE GUIDE TO IMPLEMENTING DYNAMIC LOAD SUPPORT FOR LINEAR MOTION SYSTEMS

SUPPORTING LINEAR MOTION: A COMPLETE GUIDE TO IMPLEMENTING DYNAMIC LOAD SUPPORT FOR LINEAR MOTION SYSTEMS SUPPORTING LINEAR MOTION: A COMPLETE GUIDE TO IMPLEMENTING DYNAMIC LOAD SUPPORT FOR LINEAR MOTION SYSTEMS Released by: Keith Knight Catalyst Motion Group Engineering Team Members info@catalystmotiongroup.com

More information

Frequency-based method to optimize the number of projections for industrial computed tomography

Frequency-based method to optimize the number of projections for industrial computed tomography More Info at Open Access Database www.ndt.net/?id=18739 Frequency-based method to optimize the number of projections for industrial computed tomography Andrea Buratti 1, Soufian Ben Achour 1, Christopher

More information

Photoelastic and numerical stress analysis of a 2D contact problem and 3D numerical solution for the case of a rigid body on a deformable one

Photoelastic and numerical stress analysis of a 2D contact problem and 3D numerical solution for the case of a rigid body on a deformable one Computational Methods and Experimental Measurements XV 167 Photoelastic and numerical stress analysis of a 2D contact problem and 3D numerical solution for the case of a rigid body on a deformable one

More information

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442 Industrial Metrology Multisensor Measuring Machines O-INSPECT 322/442 The moment the answer is right in front of your eyes. This is the moment we work for. // Certainty Made By Zeiss 2 Table of Contents

More information

Calibration and setup of a tool probe

Calibration and setup of a tool probe Calibration and setup of a tool probe Fundamentals Tool-setting is the process of determining geometric information length, radius and / or diameter of a cutting tool using a tool-setting device. Some

More information

Precision Engineering

Precision Engineering Precision Engineering 37 (213) 599 65 Contents lists available at SciVerse ScienceDirect Precision Engineering jou rnal h om epage: www.elsevier.com/locate/precision Random error analysis of profile measurement

More information

SIMULATION AND VISUALIZATION IN THE EDUCATION OF COHERENT OPTICS

SIMULATION AND VISUALIZATION IN THE EDUCATION OF COHERENT OPTICS SIMULATION AND VISUALIZATION IN THE EDUCATION OF COHERENT OPTICS J. KORNIS, P. PACHER Department of Physics Technical University of Budapest H-1111 Budafoki út 8., Hungary e-mail: kornis@phy.bme.hu, pacher@phy.bme.hu

More information

2: Static analysis of a plate

2: Static analysis of a plate 2: Static analysis of a plate Topics covered Project description Using SolidWorks Simulation interface Linear static analysis with solid elements Finding reaction forces Controlling discretization errors

More information

5-Axis Flex Track Drilling Systems on Complex Contours: Solutions for Position Control

5-Axis Flex Track Drilling Systems on Complex Contours: Solutions for Position Control 5-Axis Flex Track Drilling Systems on Complex Contours: Solutions for Position Control 2013-01-2224 Published 09/17/2013 Joseph R. Malcomb Electroimpact Inc. Copyright 2013 SAE International doi:10.4271/2013-01-2224

More information

3D Coordinate Transformation Calculations. Space Truss Member

3D Coordinate Transformation Calculations. Space Truss Member 3D oordinate Transformation alculations Transformation of the element stiffness equations for a space frame member from the local to the global coordinate system can be accomplished as the product of three

More information