onlinecomponents.com

Size: px
Start display at page:

Download "onlinecomponents.com"

Transcription

1 Diode Modules EMG...-DIO. Diode circuits carry out various tasks in electrical and, in particular, electronic control systems, such as: Electrical decoupling of messages in alarm systems Use as spark extinguishing diodes to limit surge voltages from inductive loads, e.g., solenoid valves, DC relays or similar. In order to meet these requirements, diode modules are available as "diode gates" with combined positive or negative polarity or as diodes that can be freely assigned. PHOENIX CONTACT GmbH & Co. KG 8 Blomberg, Germany Phone Fax

2 Diode Modules EMG -DIO. for EMG -DIO 8 mm (. in.) P With positive M With negative mm (. in.) M [mm ] AWG [A] [V] Connection data * * Diode module with diodes N 00 N 08 Diode module with diodes N 08 N 08 Diode module with diodes N 00 N 00 (0. in.) EMG -DIO With or diodes Module width. mm (0.88 in.) EMG -DIOE EMG -DIOE-N08 EMG -DIOP-N08 EMG -DIOM-N08 EMG -DIOP EMG -DIOM EMG-GKS EMG -DIO... E E-N08 P-N08 P M-N08 M 0 V AC 0 V AC 0 V AC 0 V AC 00 V 000 V 000 V 00 V µa 0 µa 0 µa µa 0.8 V, approx. 0.8 V, approx. 0.8 V, approx. 0.8 V, approx. 0. A. A. A 0. A 0. A A A 0. A -0 C to +0 C (- F to + F) IEC /IEC A/DIN VDE 00-:8-0, DIN VDE 00:88-0 PHOENIX CONTACT page of

3 Diode Modules EMG -DIO. for EMG -DIO 8 0 P M mm (. in.) 8 0 With positive polarity P 8 0 M With negative polarity mm (. in.) M [mm ] AWG [A] [V] Connection data * * Diode module with 8 diodes N 00 N 08 Diode module with 8 diodes N 08 N 08 Diode module with diodes N 00 N 00 (0. in.) EMG -DIO With 8 or diodes Module width mm (. in.) EMG -DIO8E EMG -DIO8E-N08 EMG -DIO8P-N08 EMG -DIO8M-N08 EMG -DIOP EMG -DIOM EMG-GKS 0 0 EMG -DIO... 8E 8E-N08 8P-N08 P 8M-N08 M 0 V AC 0 V AC 0 V AC 0 V AC 00 V 000 V 000 V 00 V µa 0 µa 0 µa µa 0.8 V, approx. 0.8 V, approx. 0.8 V, approx. 0.8 V, approx. 0. A. A. A 0. A 0. A 0. A 0. A 0. A -0 C to +0 C (- F to + F) IEC /IEC A/DIN VDE 00-:8-0, degree of pollution, Surge Voltage Category III; DIN VDE 00:88-0 PHOENIX CONTACT page of

4 Diode Module EMG 0-DIOE. for EMG 0-DIOE mm (. in.) mm (. in.) M [mm ] AWG [A] [V] Connection data * * Diode module with diodes N 00 (0. in.) EMG 0-DIO With diodes, individually wired Module width 0 mm (. in.) EMG 0-DIOE 8 EMG-GKS V AC 00 V µa 0.8 V, approx. 0. A 0. A -0 C to +0 C (- F to + F) IEC /IEC A/DIN VDE 00-:8-0, DIN VDE 00:88-0 PHOENIX CONTACT page of

5 Fuse Modules EMG 0-DIO.... for EMG 0-DIO P P With positive polarity 8 0 M mm (. in.) M With negative polarity mm (. in.) M [mm ] AWG [A] [V] Connection data * * Diode modules with diodes (0. in.) N 00 N 00 EMG 0-DIO With diodes, common cathode or common anode Module width 0 mm (. in.) EMG 0-DIOP EMG 0-DIOM 8 EMG-GKS V AC 00 V µa 0.8 V, approx. 0. A 0. A -0 C to +0 C (- F to + F) IEC /IEC A/DIN VDE 00-:8-0, degree of pollution, Surge Voltage Category III; DIN VDE 00:88-0 TNR: 00-0-en//0/0 PHOENIX CONTACT 00 PHOENIX CONTACT page of

CONTA-ELECTRONICS. Fuse, component, diode and indicator modules

CONTA-ELECTRONICS. Fuse, component, diode and indicator modules Fuse, component, diode and indicator modules In the passive electronics sector, CONTA-CLIP offers a large variety of module types which support fast, secure, and compact functionality. These modules can

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description (-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase

More information

PSR DC/ESP4/2X1/1X2

PSR DC/ESP4/2X1/1X2 PSR-...- 24DC/ESP4/2X1/1X2 Safety relay for emergency stop and safety door monitoring Data sheet 100516_en_05 PHOENIX CONTACT 2013-11-21 1 Description The safety relay can be used for emergency stop and

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet 1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5 Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

QUINT-PS-3x AC/24DC/10

QUINT-PS-3x AC/24DC/10 3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range

More information

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.: Extract from the online catalog DEK-OV- 5DC/ 24DC/ 3 Order No.: 2941361 The illustration shows the version DEK-OV- 24DC/24DC/3 Power optocoupler terminal block, input: 5 V DC, output: 3-30 V DC/3 A, terminal

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

Installation / Control Technique

Installation / Control Technique Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet 2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet 2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer

More information

IB IL 24 DI 16 IB IL 24 DI 16-PAC

IB IL 24 DI 16 IB IL 24 DI 16-PAC IB IL 24 DI 16 IB IL 24 DI 16-PAC Inline Terminal With 16 Digital Inputs Data Sheet 555302 06/2003 + Features This data sheet is only valid in association with the IB IL SYS PRO UM E User Manual or the

More information

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

DEK-REL- 5/I/1. Extract from the online catalog. Order No.: Extract from the online catalog DEK-REL- 5/I/1 Order No.: 2941183 The illustration shows the version DEK-REL- 24/I/1 Relay terminal block, with soldered-in miniature relays, contact (AgNi +Au): small to

More information

PSR UC/ESAM4/3X1/1X2/B

PSR UC/ESAM4/3X1/1X2/B Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC

More information

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description. Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety

More information

PLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description

PLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description PLC-R 2HC PLC INERFCE With SPD Relay, High-Current Version INERFCE Data Sheet 022_03_en PHOENIX CONC - 02/08 Description number of applications such as electrical heating systems require higher continuous

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PSR-PS21. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

onlinecomponents.com

onlinecomponents.com Uninterruptible Power Supply Unitfor Universal Use. Short Description Uninterruptible Power Supply Units for Buffering Long-Term terruptions Saves space thanks to the compact, uniform design Integrated

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40 Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/4DC/40. Short Description Uninterruptible Power Supply Units for Buffering Long-Term terruptions Saves space thanks to the compact, uniform

More information

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11 CONTROL CABINET KR C1 A Technical Data 1of 11 e Copyright KUKA Roboter GmbH This documentation or excerpts therefrom may not be reproduced or disclosed to third parties without the express permission of

More information

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet 2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

REL-MR- 12DC/ Extract from the online catalog. Order No.: Pluggable miniature relays, with power contact, 2 PDT, input voltage 12 V DC

REL-MR- 12DC/ Extract from the online catalog. Order No.: Pluggable miniature relays, with power contact, 2 PDT, input voltage 12 V DC Extract from the online catalog REL-MR- 12DC/21-21 Order No.: 2961257 Pluggable miniature relays, with power contact, 2 PDT, input voltage 12 V DC Commercial data EAN 4017918163525 Pack 10 pcs. Customs

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine

More information

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet CDC 51 1 F000 1 7 6 5 8 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 00 h, for the adjustment of the pulse time c/o contacts nd c/o contact can be

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

Switching relay CT-IRE with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact Data sheet Switching relay CT-IRE with 1 c/o (SPDT) contact The CT-IRE is a switching relay from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact The CT-ARE is an electronic time relay with OFF-delay. It is from the CT-E range. The CT-E range is the economic

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX 1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas -PS-100-240AC/24/5/EX POWER provides: Preventive function monitoring through professional signaling Global use due to a

More information

Messaging module CP-C MM

Messaging module CP-C MM 2CDC 271 087 F0t04 Features Pluggable onto CP C range primary switch mode power supplies REMOTE OFF input to switch off the power supply unit remotely Monitoring of the input voltage of the power supply

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

PSR-PC20. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106255_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The PSR-PC20 SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

VAL-CP-1S-175. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with

More information

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE 1SVR 550 882 F 9500 CM-PBE Yellow LED - state of relay voltage and single-phase supply voltage for phase failure Monitoring of neutral

More information

PB IL 24 BK DIO 16/16

PB IL 24 BK DIO 16/16 PROFIBUS-DP/V1 Bus Coupler Station With 16 Digital Inputs and 16 Digital Outputs Data Sheet 643701 07/2003 $ "! % * This data sheet is only valid in association with the "Configuring and Installing the

More information

AS-Interface Safety at Work

AS-Interface Safety at Work AS-Interface Safety at Work Safety Monitor, Coupling adjacent AS-i networks with the Safety Monitor provides the option of a cross-network E-Stop connection and a global restart, especially with large

More information

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 12 V - 2 A Main Range of product Product or component type Power supply type Input voltage Output voltage Rated power in W Input protection

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

Safety Temperature Limiter TT-STL 50

Safety Temperature Limiter TT-STL 50 GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

PLC-RSC- 24DC/21 Order No.:

PLC-RSC- 24DC/21 Order No.: Typical release time Operating voltage display Name of protection Protective circuit/component 8 ms Yes Polarity protection Polarity protection diode Contact side Contact type Contact material Maximum

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

IBS IL 24 BK RB-T-2MBD

IBS IL 24 BK RB-T-2MBD IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

AC/DC and DC/DC Converters

AC/DC and DC/DC Converters AC/DC and s DC/DC converter Switch mode MDD MDD MDD 4 V DC 4 V DC 4 V DC Output 4 V DC Output V DC Output V DC IP0 Protection ouch-protected (VG 4) INPU Switching regulator OUPU Art.-No. 4 V DC/0, A 7

More information

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h. On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

VAL-CP-3S-350. Extract from the online catalog. Order No.:

VAL-CP-3S-350. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page

More information

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 5 A Main Range of product Product or component type Power supply type Input voltage Output voltage Rated power in W Input protection

More information

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA 4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B Controller Board for PC Systems With PCI Bus Data Sheet 6039B 01/2002 Product Description INTERBUS Generation 4 controller board with a host interface for the PCI bus. Features INTERBUS protocol (IEC 6

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.:

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.: Extract from the online catalog PLC-RSC- 24DC/21 Order No.: 2966171 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 0.6 A Complementary Input voltage limits Network frequency Inrush current Main Range of product Product or component type Power supply

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum: 471 M41 H31 Betriebsanleitung MSS-Zentraleinheit Operating instructions MSS central control unit Notice d'utilisation Unité centrale MSS Istruzioni d'impiego Centralina MSS Datum: 06.09.2005 , Datum: 06.09.2005

More information

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 60 W Main Range of product Product or component type Power supply type Rated power in W Input voltage Output voltage Power

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit. Safety controller Vital Approvals: TÜV Nord Vital 1 TÜV Rheinland Vital and 3 Control of: Entire safety system based on the dynamic safety circuit. Features: Vital is based on a single channel safety concept

More information