CONTA-ELECTRONICS. Fuse, component, diode and indicator modules

Size: px
Start display at page:

Download "CONTA-ELECTRONICS. Fuse, component, diode and indicator modules"

Transcription

1 Fuse, component, diode and indicator modules In the passive electronics sector, CONTA-CLIP offers a large variety of module types which support fast, secure, and compact functionality. These modules can be mounted with their combi-base on either the TS 32 or TS 35 DIN rails. They feature a screw PCB terminal connection with a rated crosssection of 2.5 mm². Customer-specific descriptions can be attached using the standard PMC Pocket-Maxicard Quick marking system. The PMCs fit on labelling channels located on both sides of the orange-coloured fitting trough.

2 Fuse, component, diode and indicator modules Fuse modules SM The SM fuse modules are designed with three or six micro-fuse receptacles. Each is separated with screw-pcb terminals. The fuse receptacles can hold micro-fuses in the 5x20 size. In the...g designs, the entries for the fuse receptacles are connected to each other via the PCB. This allows for a shared power supply. Component modules BSM The BSM component module features two rows of solder pins, attached parallel to the PCB. They are connected via circuit tracks, with screw-pcb terminals. The area on the opposite side to the solder pins may be used for soldering on a variety of user-side components, such as resistors, diodes, capacitors or varistors. Diode modules DM Different components, such as diodes or diodes with resistors, can be connected in parallel or in series using the DM diode modules. These diode circuits fulfil a variety of tasks in the area of electrical and electronic controls. These include: protection against polarity reversal, the electric decoupling of warning signals, spark-repression diodes for overvoltages from inductive loads such as magnet valves or DC relays, and lamp test modules for the detection and decoupling of group status messages. The modules are available in minus-pole or plus-pole designs, or as freely-switchable units. S-, B-, D-, A-modules Lamp test modules LPM The LPM lamp test modules are for the detection and decoupling of group status messages. They serve as visual indicators of the switching or signal status. The LPM-K modules feature diodes which are connected in pairs on the cathode side. They are freely-switchable on the anode. On the modules, the diodes are connected in pairs on the cathode side. One anode from the connected pair is connected to a common collection point with the other anodes. 143

3 Fuse modules SM Modules delivered standard with 3 or 6 fuse cartridges Suitable for 5x20 fuse cartridges Available upon request with individually-switched fuse paths, or as a distributor with a shared feedin SM E Individually switchable SM G Shared feed-in SM 3-E SM 3-G Cat. no./qty / /1 87 x 24 x 77 mm 87 x 24 x 77 mm 51 g 51 g SM 6-E SM 6-G Cat. no./qty / /1 87 x 47 x 77 mm 87 x 47 x 77 mm 104 g 104 g DIN-VDE specifications Operating temperature -20 to +50 C -20 to +50 C Stripping length 7 mm 7 mm Wire connect cross-section 0.2 to 2.5 mm to 2.5 mm 2 Screw connection AWG AWG Max. operating voltage 250 V AC 250 V AC Rated current 6.3 A max. per current path 4 A max., with simultaneous loads 6.3 A max. per current path 4 A max., with simultaneous loads Max. load at point L1 16 A 16 A Standard fuse 6.3 A 6.3 A 144

4 Component modules BSM BSM Two rows of soldering pins for versatile assembly with components BSM 4 Cat. no./qty /1 87 x 27 x 57 mm 45 g 2 rows for 4 poles BSM 4/AD* Cat. no./qty /1 87 x 27 x 57 mm 62 g 2 rows for 4 poles BSM 8 Cat. no./qty /1 87 x 47 x 57 mm 79 g 2 rows for 8 poles BSM 8/AD* Cat. no./qty /1 87 x 47 x 57 mm 102 g 2 rows for 8 poles BSM 12 Cat. no./qty /1 87 x 68 x 57 mm 100 g 2 rows for 12 poles BSM 12/AD* Cat. no./qty /1 87 x 68 x 57 mm 135 g 2 rows for 12 poles DIN-VDE specifications Operating temperature -20 to +50 C -20 to +50 C -20 to +50 C Stripping length 7 mm 7 mm 7 mm Wire connect cross-section 0.2 to 2.5 mm to 2.5 mm to 2.5 mm 2 Screw connection AWG AWG AWG Distance between pins 35 mm 35 mm 35 mm Height of soldering pins approx. 5 mm approx. 5 mm approx. 5 mm Solder pin grid/pitch 5.08 mm 5.08 mm 5.08 mm Max. operating voltage 250 V AC 250 V AC 250 V AC Max. rated current 5 A 5 A 5 A S-, B-, D-, A-modules *The.../AD modules must be used when the operating voltage exceeds 30 V AC/60 V DC. 145

5 Diode modules DM DM 26-A DM 26-K Diode modules with freely switchable diodes, and also diode gates with shared anodes or shared cathodes These modules can be used for protection against reverse polarity, decoupling, and arc suppression DM 26-A DM 26-K Cat. no./qty / /1 87 x 46 x 72 mm 87 x 46 x 72 mm 115 g 115 g DM 26-A/AD* DM 26-K/AD* Cat. no./qty / /1 87 x 46 x 72 mm 87 x 46 x 72 mm 140 g 140 g 104g 104g DIN-VDE specifications Operating temperature -20 to +50 C -20 to +50 C Stripping length 7 mm 7 mm Wire connect cross-section 0.2 to 2.5 mm to 2.5 mm 2 Screw connection AWG AWG Max. operating voltage 250 V AC/DC 250 V AC/DC Diode reverse voltage 1000 V 1000 V Max. diode current 0.5 A 0.5 A Total current per module 10 A 10 A Diode type 1 N N 4007 Reverse current of diode 5 µa 5 µa On-state voltage of diode 0.8 V 0.8 V *The.../AD modules must be used when the operating voltage exceeds 30 V AC/60 V DC. Designs with other diode types are available upon request. 146

6 Diode modules DM DM DM-A DM-K Diode modules with freely switchable diodes, and also diode gates with shared anodes or shared cathodes These modules can be used for protection against reverse polarity, decoupling, and arc suppression DM 4 DM 14-A DM 14-K Cat. no./qty / / /1 87 x 27 x 57 mm 87 x 49 x 57 mm 87 x 49 x 57 mm 44 g 80 g 80 g DM 4/AD* DM 14-A/AD DM 14-K/AD Cat. no./qty / / /1 87 x 27 x 57 mm 87 x 49 x 57 mm 87 x 49 x 57 mm 62 g 101 g 101 g DM 8 DM 22-A DM 22-K Cat. no./qty / / /1 87 x 47 x 57 mm 87 x 68 x 57 mm 87 x 68 x 57 mm 78 g 109 g 109 g DM 8/AD* DM 22-A/AD DM 22-K/AD Cat. no./qty / / /1 87 x 47 x 57 mm 87 x 68 x 57 mm 87 x 68 x 57 mm 99 g 138 g 138 g DM 12 Cat. no./qty /1 87 x 69 x 57 mm 107 g DM 12/AD* Cat. no./qty /1 Size (L x W x H) with TS3 5 x x 69 x 57 mm 135 g DM 14 Cat. no./qty /1 87 x 46 x 57 mm 116 g DM 14/AD Cat. no./qty /1 87 x 46 x 57 mm 147 g DIN-VDE specifications Operating temperature -20 to +50 C -20 to +50 C -20 to +50 C Stripping length 7 mm 7 mm 7 mm Wire connect cross-section 0.2 to 2.5 mm to 2.5 mm to 2.5 mm 2 Screw connection AWG AWG AWG Max. operating voltage 250 V AC/DC 250 V AC/DC 250 V AC/DC Diode reverse voltage 1000 V 1000 V 1000 V Max. diode current 1 A 1 A 1 A Total current per module - 6 A 6 A Diode type 1 N N N 4007 Reverse current of diode 5 µa 5 µa 5 µa On-state voltage of diode 0.8 V 0.8 V 0.8 V S-, B-, D-, A-modules *The.../AD modules must be used when the operating voltage exceeds 30 V AC/60 V DC. Designs with other diode types are available upon request. 147

7 Lamp test modules LPM Lamp test modules for the detection and decoupling of group status messages The LPM-K modules feature diodes which are connected in pairs on the cathode side. They are freely-switchable at the anode. The LPM-A modules feature diodes which are connected in pairs on the cathode side. One anode from the connected pair is connected to a common collection point with the other anodes. LPM LPM-A LPM 8-4K LPM 7-A Cat. no./qty / /1 87 x 49 x 57 mm 87 x 49 x 57 mm 74 g 80 g LPM 8-4K/AD* LPM 7-A/AD* Cat. no./qty / /1 87 x 49 x 57 mm 87 x 49 x 57 mm 96 g 109 g LPM 12-6K LPM 11-A Cat. no./qty / /1 87 x 68 x 57 mm 87 x 68 x 57 mm 100 g 110 g LPM 12-6K/AD* LPM 11-A/AD* Cat. no./qty / /1 87 x 68 x 57 mm 87 x 68 x 57 mm 130 g 198 g LPM 20-10K LPM 20-A Cat. no./qty / /1 87 x 109 x 57 mm 87 x 115 x 57 mm 152 g 176 g LPM 20-10K/AD* LPM 20-A/AD* Cat. no./qty / /1 87 x 109 x 57 mm 87 x 115 x 57 mm 190 g 215 g LPM 40-A Cat. no./qty /1 87 x 216 x 57 mm 325 g LPM 40-A/AD* Cat. no./qty /1 87 x 216 x 57 mm 390 g DIN-VDE specifications Operating temperature -20 to +50 C -20 to +50 C Stripping length 7 mm 7 mm Wire connect cross-section 0.2 to 2.5 mm to 2.5 mm 2 Screw connection AWG AWG Max. operating voltage 250 V AC/DC 250 V AC/DC Diode reverse voltage 1000 V 1000 V Max. diode current 1 A 1 A Total current per module - - Diode type 1 N N 4007 Reverse current of diode 5 µa 5 µa On-state voltage of diode 0.8 V 0.8 V *The.../AD modules must be used when the operating voltage exceeds 30 V AC/60 V DC. Designs with other diode types are available upon request. 148

onlinecomponents.com

onlinecomponents.com Diode Modules EMG...-DIO. Diode circuits carry out various tasks in electrical and, in particular, electronic control systems, such as: Electrical decoupling of messages in alarm systems Use as spark extinguishing

More information

CONTA-ELECTRONICS. Interface modules

CONTA-ELECTRONICS. Interface modules CONTA-ELECTRONICS allow for a passive mechanical-electrical implementation of standard connectors onto screw or tension-spring PCB terminals. The individual signals of the multi-pole or high-pole connectors

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) , LINEAR LED DRIVERS ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) 186695, 186696 Typical Applications Built-in in linear luminaires for Industrial lighting ComfortLine with selectable current HIGH POWER

More information

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1) K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186591, 186592, 186593, 186594, 186595, 186669 Typical Applications Built-in in or independent version for Shop lighting Downlights EasyLine with fixed output current

More information

ELECTRONICS Electronics

ELECTRONICS Electronics ELECTRONICS CONTA-ELECTRONICS CONTA-ELECTRONICS Overview of the product line Conta-Clip Our Company 3 CONTA-CLIP on the internet 4 CONTA-ELECTRONICS General Information 5 Product overview 6 DC power supplies

More information

COMPACT LED CONVERTERS 48 V

COMPACT LED CONVERTERS 48 V COMPACT LED CONVERTERS 48 V EasyLine 48 V 186691, 186692 Typical Applications Shop lighting for 48 V systems Furniture lighting EasyLine 48 V VERY COMPACT SHAPE VERY LOW RIPPLE CURRENT LONG SERVICE LIFETIME:

More information

CC COMPACT DIP SWITCH

CC COMPACT DIP SWITCH CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT

More information

UF-3701 Power Board Construction Guide

UF-3701 Power Board Construction Guide Page 1/5 Soldering and Part Placement See the Chapter 3 of the MIT 6270 Manual for information on electronic assembly, including soldering techniques and component mounting. Construction Information All

More information

Solid State Remote Power Controller E /627

Solid State Remote Power Controller E /627 Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , , COMPACT LED DRIVERS ComfortLine RESIDENTIAL 186679, 186680, 186681, 186682 Typical Applications Built-in in compact luminaires for Residential lighting Downlights ComfortLine Residential VERY COMPACT SHAPE

More information

RM84 miniature relays

RM84 miniature relays RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to

More information

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets. 40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or

More information

Miniature PCB Relays A

Miniature PCB Relays A SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186719, 186720, 186721, 186722, 186723, 186724, 186725, 186726, 186727, 186728 Typical Applications Built-in in compact luminaires Shop lighting Downlights EasyLine

More information

Installation/assembly manual for DCC/Power shield

Installation/assembly manual for DCC/Power shield Installation/assembly manual for DCC/Power shield The DCC circuit consists of the following components: R1/R6 R2/R3 R4/R5 D1 C2 2 kω resistor ½ Watt (colour code Red/Black/Black/Brown/Brown) 10 kω resistor

More information

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit. Safety controller Vital Approvals: TÜV Nord Vital 1 TÜV Rheinland Vital and 3 Control of: Entire safety system based on the dynamic safety circuit. Features: Vital is based on a single channel safety concept

More information

S5-S. MRC series. Socket for square base relay C5- Connection diagram. Dimensions [mm] Technical approvals, conformities EN , EN ø4.

S5-S. MRC series. Socket for square base relay C5- Connection diagram. Dimensions [mm] Technical approvals, conformities EN , EN ø4. MRC series S5-S Socket for square base relay C5- S5-S 3-pole, 2 level Logic wiring Integrated retaining clip and labelling space 16 A 16 A / 00 V All terminals/din rail kv Terminal/terminal kv Cross-section

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching

More information

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , LINEAR LED DRIVERS EasyLine SIMPLE FIX 186712, 186713, 186714, 186715, 186716, 186760 Typical Applications Built-in in linear luminaires for Office lighting Weatherproof Luminaires EasyLine Simple Fix

More information

PN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit

PN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit CAUTION: Please make sure you have or have access to the skills necessary to assemble and use this product. Always secure the case with the included screws before applying electrical power to the power

More information

Switched-mode and uninterruptible power supplies, and electronic fuses. Let s connect. Power supply. Catalogue 2014/2015

Switched-mode and uninterruptible power supplies, and electronic fuses. Let s connect. Power supply. Catalogue 2014/2015 Switched-mode and uninterruptible power supplies, and electronic fuses Catalogue 2014/2015 Let s connect. Power supply The World of Industrial Connectivity Connections between control and sensor-actuator

More information

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain

More information

DPO A4. Description. Module with 4 digital outputs. Datasheet

DPO A4. Description. Module with 4 digital outputs. Datasheet DPO A4 Module with 4 digital outputs Datasheet Description Module with 4 digital outputs. Main characteristics: 4 digital outputs Maximum output current: 2 A for each output, 7 A total Overcurrent and

More information

Mounting and disassembly of the relay and accessories in the socket. Accessories Retainer / retractor clips and description plates

Mounting and disassembly of the relay and accessories in the socket. Accessories Retainer / retractor clips and description plates Mounting and disassembly of the relay and accessories in the socket 197 Signalling / protecting module Electromagnetic relays Retainer / retractor clip Removing the relay from the socket with a retrainer

More information

Magnetic Style Safety Interlock Switches

Magnetic Style Safety Interlock Switches Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment

More information

AC/DC and DC/DC Converters

AC/DC and DC/DC Converters AC/DC and s DC/DC converter Switch mode MDD MDD MDD 4 V DC 4 V DC 4 V DC Output 4 V DC Output V DC Output V DC IP0 Protection ouch-protected (VG 4) INPU Switching regulator OUPU Art.-No. 4 V DC/0, A 7

More information

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700-P, 700DC-P Industrial Relays Adder Decks Description No. of N.O. Contacts Continuous Carrying Current [A] Arrangement Second Deck (0-pole) 0 700-PB00 Second Deck 700-PB40 Second Deck (4-pole)

More information

RUC-M industrial relays for DC loads

RUC-M industrial relays for DC loads Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Min. breaking capacity

More information

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14 Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

Signal Doublers. VariTrans A 20300

Signal Doublers. VariTrans A 20300 ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission

More information

R15 industrial relays of small dimensions

R15 industrial relays of small dimensions R15 127 R15 2 C/O R15 3 C/O R15 4 C/O Contact data Number and type of contacts Contact material Max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated

More information

Power Electronics. Semiconductor relay / - contactor

Power Electronics. Semiconductor relay / - contactor Power Electronics Semiconductor relay / - contactor PH 9260 POWERSWITCH 0247349 Semiconductor relay PH 9260.91 Semiconductor contactor PH 9260.91/000/01 AC semiconductor relay / -contactor According to

More information

Voltage surge suppressor

Voltage surge suppressor Sheet 1 PRODUCT DESCRIPTION AC/DC converter are used to rectify the line supply voltage for the DC link, normally are used uncontrolled or controlled rectifier without or with regenerative feedback unit.

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection 4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

CZH-LABS Electronics-Salon

CZH-LABS Electronics-Salon CZH-LABS Electronics-Salon AC/DC control SPDT 16Amp Pluggable Power Relay Module Model: MD-D209 D210 D211 D231 Series Version: 2.0 Series Channel Control Voltage Page MD-D209 2 AC/DC 12 or 24V 2 ~ 6 MD-D210

More information

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , , COMPACT LED DRIVERS EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186463, 186464, 186531, 186532 Typical Applications Built-in in reflector luminaires Shop illumination Downlights EasyLine with selectable

More information

I/O Expansion Module Installation & Reference

I/O Expansion Module Installation & Reference Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs

More information

Diodes Zener diodes. Electronics Diodes. Terry Sturtevant. Wilfrid Laurier University. September 9, 2015

Diodes Zener diodes. Electronics Diodes. Terry Sturtevant. Wilfrid Laurier University. September 9, 2015 Electronics Diodes Wilfrid Laurier University September 9, 2015 Diode an electronic device which passes current in one direction only Diode an electronic device which passes current in one direction only

More information

Time Counters mini "h", DC Version

Time Counters mini h, DC Version Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable

More information

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet 1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information... Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135 General ordering data Order No. 1715360000 Part designation LM5.00/3/135 OR Version EAN 4008190365240 Qty. 500 pc(s). PCB terminal, Clamping yoke connection, Soldered connection, Clamping range, max.:

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

Experiment #2 PLC Input Output Wiring Methods. OBJECTIVES After successfully completing this laboratory, you should be able to:

Experiment #2 PLC Input Output Wiring Methods. OBJECTIVES After successfully completing this laboratory, you should be able to: Experiment #2 PLC Input Output Wiring Methods OBJECTIVES After successfully completing this laboratory, you should be able to: Read and explain the nameplate of DELTA s PLC DVP Series Model. Make different

More information

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range. I/O Block Base G7A Reduces Wiring while Providing I/O Flexibility Mount I/O relays and I/O SSRs freely. Electric-shock preventive (finger-touch protection) terminal block incorporated conforming to VDE

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks. 9 Relay I/O Block Reduces Wiring within the Control Panel and Reduces Installation Time 1 Compact 16-pt models: 182 W l 85 D l 68 H mm; 8-pt block width is 102 mm 1 Can be connected to the PLC with a connecting

More information

SRI-02 Speech Recognition Interface

SRI-02 Speech Recognition Interface SRI-02 Speech Recognition Interface Data & Construction Booklet The Speech Recognition Interface SRI-02 allows one to use the SR-07 Speech Recognition Circuit to create speech controlled electrical devices.

More information

The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves.

The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves. Connector Connector system The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves. The connectors with cable entry conform

More information

Relays & Sockets RR Series Power Relays. Part Number Selection

Relays & Sockets RR Series Power Relays. Part Number Selection RR Series Power Relays Key features: SPDT through PDT, A contacts Midget power type relays Available in pin and blade terminal styles. Options include an indicator, check button for test operations and

More information

CP5176 Assembly guide. Soldering. CP5176 Assembly guide Main PCB PCB split. Document revision 2.1 Last modification : 12/11/17

CP5176 Assembly guide. Soldering. CP5176 Assembly guide Main PCB PCB split.  Document revision 2.1 Last modification : 12/11/17 CP5176 Assembly guide Safety warning The kits are main powered and use potentially lethal voltages. Under no circumstance should someone undertake the realisation of a kit unless he has full knowledge

More information

WE TAKE CARE OF EVERYTHING IN THE ELECTRICAL CABINET

WE TAKE CARE OF EVERYTHING IN THE ELECTRICAL CABINET WE TAKE CARE OF EVERYTHING IN THE ELECTRICAL CABINET Users of connection systems have come to rely on CONTA-CLIP s broad portfolio of products and for good reason. Our products are developed in close consultation

More information

Mounting and sub-assemblies of the relay and accessories in the socket. Accessories retainer / retractor clips and description plates

Mounting and sub-assemblies of the relay and accessories in the socket. Accessories retainer / retractor clips and description plates Mounting and sub-assemblies of the relay and accessories in the socket Signalling / protecting module type M... Electromagnetic relays Retainer / retractor clip Removing the relay from the socket with

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES TM LDD M SERIES LDD M SERIES INSTRUCTION MANUAL P O Box Bozeman, MT 9 Phone (0) -90 Fax (0) -9 email sales@wavelengthelectronics.com www.wavelengthelectronics.com TABLE OF CONTENTS Features... Customer

More information

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , , LINEAR LED DRIVERS PrimeLine DALI DIMMABLE 186445, 186446, 186575, 186576, 186577, 186578 Linear LED drivers with preset operating window or individual programming Typical Applications Built-in in linear

More information

You need the following components to assemble the Black n Wood Nixie Clock circuit board:

You need the following components to assemble the Black n Wood Nixie Clock circuit board: You need the following components to assemble the Black n Wood Nixie Clock circuit board: Quantity Designator Description 1 Battery Battery, CR1220 1 Battery Battery holder 3 Button 1, Button 2, Button

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

BENCHMARK MEDIA SYSTEMS, INC.

BENCHMARK MEDIA SYSTEMS, INC. BENCHMARK MEDIA SYSTEMS, INC. RLY-106 Instruction Manual 1.0 Introduction...1 2.0 Input and Output Connections...1 2.1 Connection Alternatives...2 3.0 Relay Ratings...2 4.0 Applications...4 4.1 Audio Signal

More information

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus 4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output

More information

PLC-RSC- 24DC/21 Order No.:

PLC-RSC- 24DC/21 Order No.: Typical release time Operating voltage display Name of protection Protective circuit/component 8 ms Yes Polarity protection Polarity protection diode Contact side Contact type Contact material Maximum

More information

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data Features 2 C/O or 2 N/O contacts Sensitive coil 400 mw DC- or AC-coil 5 kv / 10 mm coil-contact Protection class II (VDE 0700) Height 15.7 mm Sockets with PCB-type or screw-type terminals Applications

More information

AS-Interface Safety at Work

AS-Interface Safety at Work AS-Interface Safety at Work Safety Monitor, Coupling adjacent AS-i networks with the Safety Monitor provides the option of a cross-network E-Stop connection and a global restart, especially with large

More information

MSR178DP. Description. Features. Specifications

MSR178DP. Description. Features. Specifications MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications

More information

RB-Pol V, 300mA Step-Down Voltage Regulator D24V3F3

RB-Pol V, 300mA Step-Down Voltage Regulator D24V3F3 RB-Pol-220 3.3V, 300mA Step-Down Voltage Regulator D24V3F3 The compact (0.4 0.5 ) D24V3F3 switching step-down (or buck) voltage regulator takes an input voltage between 4.3 V and 42 V and efficiently reduces

More information

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F) MOS FET Relay G3VM- XN(F)/4N(F) SSR for Switching Analog Signals, with an I/O Dielectric Strength of 2.5 kvac Using Optical Isolation Switches minute analog signals. Linear voltage and current characteristics.

More information

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , , LINEAR LED DRIVERS ComfortLine NFC 186697, 186698, 186699, 186700 Typical Applications Built-in in linear luminaires for Office lighting Industrial lighting ComfortLine NFC SELECTABLE OUTPUT CURRENT (NFC)

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. LTD METERSUK sales@meters.co.uk 01524 555 929 3 MOD CT Series Smart Energy Meter KEY FEATURES Three phase metering Three Phase metering, 7 din modules Accuracy class 1 according to IEC62053-21 LCD display,

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

PI84 with socket GZM80 interface relays

PI84 with socket GZM80 interface relays RM84 + GZM80 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) Min. switching current Max. inrush current Rated current

More information

RM4-2NO & RM8-2NO 180x77x65 (RM8 size) RM8-1C. RM8-2C & RM16-2C 202.5x77x68 (RM8 size) 8 or changeover. Yes. Yes.

RM4-2NO & RM8-2NO 180x77x65 (RM8 size) RM8-1C. RM8-2C & RM16-2C 202.5x77x68 (RM8 size) 8 or changeover. Yes. Yes. Introduction Products offer a range of relay modules designed to provide Programmable controllers, PLC's and Microprocessor systems a power switching capability to their standard solid state outputs. The

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications MUSIUM RESTAURANT SOUVENIR SHOP EXIT LinkRay-LED Drivers EasyLine With Selectable Current LINK RAY LED DRIVERS EasyLine MultiCurrent LinkRay LED DRIVERS EasyLine WITH SELECTABLE CURRENT LinkRay LED Drivers

More information

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC) Solid-state Relay Compact SSRs Ideal for Built-in Applications Vertical, compact SSRs with an operation indicator offered in versatile variations. Can be mounted side by side with an electromagnetic relay

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

What are output transducers An output transducer will convert electrical signals passed to it by the process into another form of energy.

What are output transducers An output transducer will convert electrical signals passed to it by the process into another form of energy. What are output transducers An output transducer will convert electrical signals passed to it by the process into another form of energy. ACTIVITY Can you find the symbols of the output components listed

More information

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

DEK-REL- 5/I/1. Extract from the online catalog. Order No.: Extract from the online catalog DEK-REL- 5/I/1 Order No.: 2941183 The illustration shows the version DEK-REL- 24/I/1 Relay terminal block, with soldered-in miniature relays, contact (AgNi +Au): small to

More information

SAMPLE. MOVs are sometimes referred

SAMPLE. MOVs are sometimes referred attenuate (weaken or reduce) a spike or transient pulse. Recall that in a capacitive circuit the voltage lags the current, and in an inductive circuit the current lags the voltage. Inductance added METAL-OXIDE

More information

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Model INSTRUCTION MANUAL DIGITAL MULTIMETER Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT

More information

!There are two kit models. The ZCTK-120 is designed to operate with.!the pulse output is isolated from the mains line voltage. A pull-up resistor

!There are two kit models. The ZCTK-120 is designed to operate with.!the pulse output is isolated from the mains line voltage. A pull-up resistor CAUTION: Please make sure you have or have access to the skills necessary to assemble and use this product. Always secure the case with the included screws before applying electrical power to the power

More information