23 CP Add Tracking Identifier and UID to Segmentation Instances

Size: px
Start display at page:

Download "23 CP Add Tracking Identifier and UID to Segmentation Instances"

Transcription

1 23 CP Add Tracking Identifier and UID to Segmentation Instances Page 1 1 Status Final Text 2 Date of Last Update 2016/01/19 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter Name QIICR 6 Submission Date 2015/05/07 7 Correction Number CP Log Summary: Add Tracking Identifier and UID to Segmentation Instances 9 Name of Standard 10 PS3.3, PS3.6, PS3.15, PS c 11 Rationale for Correction: 12 Currently, some measurement related and CAD SR templates include a human readable identifier and a UID for longitudinal tracking 13 of lesions or other findings that may have multiple content items within one SR or occur in multiple SR instances. Often specific 14 occurences of such lesions on an image or at one particular timepoint will be associated with Segmentation instances, and these 15 are referenced from the SR using the Segmentation SOP Instance UID and Segment Number. 16 It is desirable to also be able to identify lesions in the same manner within a segmentation instance, so that the lesion may be 17 identified without the need to consult the SR (or indeed, without the need for there to be an SR, e.g., if no measurements are made, 18 or for there to be an SR at the time of segmentation). 19 This correction incorporates an earlier proposal, CP 757, which addressed the same issue for both Segmentation and RT Structure 20 Set objects, and has been cancelled. 21 Correction Wording: 22 - Final Text -

2 39 CP Add Tracking Identifier and UID to Segmentation Instances Page 2 1 Amend DICOM PS as follows: 2 C Segment Description Macro 3 4 Table C Segment Description Macro Attributes 5 Attribute Name Tag Type Attribute Description 6 Segment Number (0062,0004) 1 Identification number of the segment. The value of Segment Number (0062,0004) shall 7 be unique within the Segmentation instance in which it is created. See???. 8 Segment Label (0062,0005) 1 User-defined label identifying this segment. This may be the same as Code Meaning 9 (0008,0104) of Segmented Property Type Code Sequence (0062,000F) Tracking ID (0062,0020) 1C A text label used for tracking a finding or feature, potentially across multiple 12 reporting objects, over time. This label shall be unique within the domain in which 13 it is used. 14 Required if Tracking UID (0062,0021) is present. 15 Note May be used for tracking a finding or feature that is described by 17 this segment, potentially across multiple objects, over time May or may not have the same value as Segment Label (0062,0005) Related SR instances may exist, for example, to record measurements 20 related to this segment, but need not exist for this Attribute to be 21 used This Attribute will have the same value as the value of the (112039, 23 DCM, "Tracking Identifier") content item in SR instances that 24 reference this Segment in this Segmentation Instance. 25 Tracking UID (0062,0021) 1C A unique identifier used for tracking a finding or feature, potentially across multiple 26 reporting objects, over time. 27 Required if Tracking ID (0062,0020) is present. 28 Note May be used for tracking a finding or feature that is described by 30 this segment, potentially across multiple objects, over time Related SR instances may exist, for example, to record measurements 32 related to this segment, but need not exist for this Attribute to be 33 used This Attribute will have the same value as the value of the (112040, 35 DCM, "Tracking Unique Identifier") content item in SR instances that 36 reference this Segment in this Segmentation Instance. 37 Amend DICOM PS as follows: 38 - Final Text -

3 46 CP Add Tracking Identifier and UID to Segmentation Instances Page Registry of DICOM Data Elements 2 Table 6-1. Registry of DICOM Data Elements 3 Tag Name Keyword VR VM 4 (0062,0020) Tracking ID TrackingID UT 1 5 (0062,0021) Tracking UID TrackingUID UI 1 6 Amend DICOM PS as follows: 7 E.1.1 De-identifier 8 9 Table E.1-1. Application Level Confidentiality Profile Attributes 10 Attribute Tag Retired In Std. Basic Retain Retain Retain Retain Retain Retain Clean Clean Clean 11 Name (from Comp. Profile Safe UIDs Device Patient Long. Long. Desc. Struct. Graph. 12????) IOD Private Option Ident. Chars. Full Modif. Option Cont. Option 13 (from Option Option Option Dates Dates Option 14????) Option Option Tracking (0062,0021) N Y U K 17 UID 18 Amend DICOM PS as follows: 19 TID 1401 Area Measurement Type: Extensible Order: Significant Root: No 26 Table TID Area Measurement 27 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 28 Type 29 1 NUM D??? Value shall be > 0 30 UNITS = D??? 31 2 > INFERRED SCOORD EV (121056, DCM, C IF concept name of Row GRAPHIC TYPE = not 32 FROM "Area Outline") 1 is (G-A16A, SRT, "Area {MULTIPOINT} 33 of defined region"), and 34 IFF Row 5 or 6 not 35 present >> R-SELECTED IMAGE C XOR Row 4 37 FROM 38 4 >> SELECTED IMAGE C XOR Row 3 39 FROM 40 5 > INFERRED IMAGE EV (121214, DCM, C IF concept name of Row Reference shall be to a 41 FROM "Referenced 1 is (G-A16A, SRT, "Area Segmentation Image, 42 Segmentation of defined region"), and with a single value 43 Frame") IFF Row 2 or 6 not specified in Referenced 44 present. Frame Number 45 - Final Text -

4 47 CP Add Tracking Identifier and UID to Segmentation Instances Page 4 1 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 2 Type 3 6 > R- INFERRED IMAGE C IF concept name of Row Reference shall be to a 4 FROM 1 is (G-A16A, SRT, "Area Segmentation Image, 5 of defined region"), and with a single value 6 IFF Row 2 or 5 not specified in Referenced 7 present. Frame Number 8 7 > HAS CODE EV (G-C036, SRT, 1 U D??? 9 PROPERTIES "Measurement 10 Method") 11 8 > HAS OBS INCLUDE DTID U 12 CONTEXT Tracking Identifier 13 Content Item Descriptions 14 Row 2 "Area Outline" A Graphic Type of POINT implies that the object is a single pixel and the object's area is the area of the pixel. 15 Otherwise the type shall be a closed POLYLINE (start and end point the same) or a CIRCLE or an ELLIPSE. 16 Rows 5, 6 Referenced Frame Number (0008,1160) is an attribute of the IMAGE Content Item. 17 If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies 18 the area of defined (measured) region by pixel values in the referenced frame with value 1. For Segmentation 19 Type value FRACTIONAL, the area is computed by an implementation dependent method. 20 Frame number shall be specified even if the Segmentation SOP Instance has only a single frame. 21 Row 8 The values of (112039, DCM, "Tracking Identifier") and (112040, DCM, "Tracking Unique Identifier"), if 22 present, shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), 23 if present, in the corresponding Segment of any Segmentation instance referenced in Row TID 1402 Volume Measurement Type: Extensible Order: Significant Root: No 31 Table TID Volume Measurement 32 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 33 Type 34 1 NUM D??? Value shall be > 0 35 UNITS = D??? 36 2 > INFERRED FROM SCOORD EV (121057, DCM, 1-n UC XOR row 5, 6 GRAPHIC TYPE = not 37 "Perimeter Outline") {MULTIPOINT} 38 3 >> R-SELECTED IMAGE C XOR Row 4 39 FROM 40 4 >> SELECTED FROM IMAGE C XOR Row > INFERRED FROM IMAGE EV (121191, DCM, 1 UC XOR row 2, 6 Reference shall be to a 42 "Referenced Segmentation Image, with 43 Segment") a value specified in 44 Referenced Segment 45 Number 46 - Final Text -

5 48 CP Add Tracking Identifier and UID to Segmentation Instances Page 5 1 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 2 Type 3 6 > R- INFERRED IMAGE 1 UC XOR row 2, 5 Reference shall be to a 4 FROM Segmentation Image, with 5 a value specified in 6 Referenced Segment 7 Number 8 7 > HAS PROPERTIES CODE EV (G-C036, SRT, 1 U D??? 9 "Measurement 10 Method") 11 8 > HAS OBS INCLUDE DTID 4108 Tracking 1 U 12 CONTEXT Identifier 13 Content Item Descriptions 14 Row 2 "Perimeter The two dimensional perimeter of the volume's intersection with or projection into the image. A Graphic Type 15 Outline" of POINT implies that the volume's intersection or projection in a plane is a single pixel. A single pixel projection 16 perimeter cannot cause a volume calculation to become Otherwise the type shall be a closed POLYLINE (start and end point the same) or a CIRCLE or an ELLIPSE. 18 Rows 5, 6 Referenced Segment Number (0062,000B) is an attribute of the IMAGE Content Item. 19 If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies 20 the defined (measured) volume by pixel/voxel values in the frames of the referenced segment with value For Segmentation Type value FRACTIONAL, the volume is computed by an implementation dependent method. 22 Segment number shall be specified even if the Segmentation SOP Instance has only a single segment. 23 Row 8 The values of (112039, DCM, "Tracking Identifier") and (112040, DCM, "Tracking Unique Identifier"), if 24 present, shall match the corresponding values of Tracking ID (0062,0020) and Tracking UID (0062,0021), 25 if present, in the corresponding Segment of any Segmentation instance referenced in Row TID 1410 Planar ROI Measurements Table TID Planar ROI Measurements 29 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 30 Type 31 1 CONTAINER EV (125007, DCM, 32 "Measurement Group") 33 2 > HAS OBS TEXT DT (112039, DCM, 34 CONTEXT "Tracking Identifier") 35 3 > HAS OBS UIDREF EV (112040, DCM, 36 CONTEXT "Tracking Unique 37 Identifier") > CONTAINS IMAGE EV (121214, DCM, C XOR Row Reference shall be to a 40 "Referenced Segmentation 5 Segmentation Image, with 41 Frame") a single value specified in 42 Referenced Frame 43 Number, and with a single 44 value specified in 45 Referenced Segment 46 Number 47 - Final Text -

6 42 CP Add Tracking Identifier and UID to Segmentation Instances Page 6 1 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 2 Type 3 4 Content Item Descriptions 5 Rows 2, 3 The Tracking Identifier and Tracking Unique Identifier are defined as a text label or unique identifier (respectively) 6 used for tracking a finding or feature, potentially across multiple reporting objects, over time. As such, they are 7 distinct from the Observation UID (0040,A171), which is unique identifier of the specific Content Item and its subsidiary 8 Content Items that constitute an individual observation, and would be different for different observations on different 9 occasions of the same finding or feature. The values of these content items shall match the corresponding 10 values of Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment 11 of any Segmentation instance referenced in Row Rows 6, 7 Referenced Frame Number (0008,1160) is an attribute of the IMAGE Content Item, and shall be present with a 13 single value. 14 If the Referenced Segmentation SOP Instance has Segmentation Type (0062,0001) value BINARY, it identifies the 15 area of defined (measured) region of interest by pixel values in the referenced frame with value 1. For Segmentation 16 Type value FRACTIONAL, the area is computed by an implementation dependent method. 17 Frame number shall be specified even if the Segmentation SOP Instance has only a single frame TID 1411 Volumetric ROI Measurements Table TID Volumetric ROI Measurements 22 NL Rel with Parent VT Concept Name VM Req Condition Value Set Constraint 23 Type 24 1 CONTAINER EV (125007, DCM, 25 "Measurement Group") 26 2 > HAS OBS TEXT DT (112039, DCM, 27 CONTEXT "Tracking Identifier") 28 3 > HAS OBS UIDREF EV (112040, DCM, 29 CONTEXT "Tracking Unique 30 Identifier") > CONTAINS IMAGE EV (121191, DCM, C XOR Rows Reference shall be to a 33 "Referenced Segment") 5, 10 Segmentation Image or 34 Surface Segmentation 35 object, with a single 36 value specified in 37 Referenced Segment 38 Number Content Item Descriptions 41 - Final Text -

7 48 CP Add Tracking Identifier and UID to Segmentation Instances Page 7 1 Rows 2, 3 The Tracking Identifier and Tracking Unique Identifier are defined as a text label or unique identifier (respectively) 2 used for tracking a finding or feature, potentially across multiple reporting objects, over time. As such, they are distinct 3 from the Observation UID (0040,A171), which is unique identifier of the specific Content Item and its subsidiary Content 4 Items that constitute an individual observation, and would be different for different observations on different occasions 5 of the same finding or feature.the values of these content items shall match the corresponding values of 6 Tracking ID (0062,0020) and Tracking UID (0062,0021), if present, in the corresponding Segment of any 7 Segmentation instance referenced in Row 7. 8 Rows 6, 7 Referenced Segment Number (0062,000B) is an attribute of the IMAGE Content Item, and shall be present with a 9 single value. 10 If the Referenced SOP Instance is a Segmentation Image, it shall have a defined Frame of Reference. If it has 11 Segmentation Type (0062,0001) value BINARY, it identifies the volume of defined (measured) region of interest by 12 voxel values in the referenced segment with value 1. If it has Segmentation Type value FRACTIONAL, the volume 13 is defined by an implementation dependent method. 14 If the referenced SOP Instance is a Surface Segmentation, the referenced segment shall constitute a finite volume. 15 It identifies the volume of the defined (measured) region of interest by the interior of the finite volume. 16 Segment number shall be specified even if the Segmentation SOP Instance has only a single segment TID 4108 Tracking Identifier 19 This Template provides a means to identify an object for longitudinal tracking, potentially across multiple Structured Reports, over 20 time Type: Non-Extensible Order: Significant Root: No 27 Table TID Tracking Identifier 28 NL Rel with VT Concept Name VM Req Type Condition Value Set Constraint 29 Parent 30 1 TEXT EV (112039, DCM, C At least one of row 1 or A string of characters with 31 "Tracking Identifier") 2 shall be present. case being non-significant. 32 Leading and trailing spaces 33 and control characters are 34 forbidden UIDREF EV (112040, DCM, C At least one of row 1 or 36 "Tracking Unique 2 shall be present. 37 Identifier") 38 Content Item Descriptions 39 Tracking Identifier A human readable identifier for longitudinal tracking, e.g., "Watchlist Nodule 1". 40 Tracking Unique Identifier This is distinct from the Observation UID (0040,A171) that may be present in the data set for 41 each Content Item, which identifies only a specific observation, not an object tracked over time, 42 and each tracked object may have many observations. 43 D DICOM Controlled Terminology Definitions (Normative) 44 This Annex specifies the meanings of codes defined in DICOM, either explicitly or by reference to another part of DICOM or an ex- 45 ternal reference document or standard. 46 DICOM Code Definitions (Coding Scheme Designator "DCM" Coding Scheme Version "01") 47 - Final Text -

8 11 CP Add Tracking Identifier and UID to Segmentation Instances Page 8 1 Table D-1. DICOM Controlled Terminology Definitions 2 Code Value Code Meaning Definition Notes Tracking Identifier A text label used for tracking a finding or feature, potentially across 4 multiple reporting objects, over time. This label shall be unique within 5 the domain in which it is used. Corresponds to Tracking ID 6 (0062,0020) Tracking Unique Identifier A unique identifier used for tracking a finding or feature, potentially 8 across multiple reporting objects, over time. Corresponds to Tracking 9 UID (0062,0021) Final Text -

17 CP Add description and example for ROI distance measurements with coordinates

17 CP Add description and example for ROI distance measurements with coordinates 17 CP-1845 - Add description and example for ROI distance measurements with coordinates Page 1 1 Status Jan 2019 Voting Packet 2 Date of Last Update 2018/11/12 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com

More information

DICOM Correction Proposal Form

DICOM Correction Proposal Form DICOM Correction Proposal Form Tracking Information - Administration Use Only Correction Proposal Number CP-261 STATUS Date of Last Update 6/13/2001 Person Assigned Submitter Name Harry Solomon Harry Solomon

More information

17 CP Correct SR Encoding Example

17 CP Correct SR Encoding Example 17 CP-1711 - Correct SR Encoding Example Page 1 1 Status November 2017 Packet 2 Date of Last Update 2017/09/13 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter Name David Clunie

More information

27 CP Remove Dimension Index Sequence requirement for WSI when Dimensions implicitly defined Page 1

27 CP Remove Dimension Index Sequence requirement for WSI when Dimensions implicitly defined Page 1 27 CP-1822 - Remove Dimension Index Sequence requirement for WSI when Dimensions implicitly defined Page 1 28 by TILED_FULL 1 Status Assigned 2 Date of Last Update 2018/07/31 3 Person Assigned David Clunie

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-756 Log Summary: of Modification Addition Name of Standard PS 3.16 2007 Rationale for Correction Calculations of areas and volumes may require that the method

More information

DICOM Correction Item

DICOM Correction Item Specify contents for DICOMDIR records DICOM Correction Item Correction Number CP 688 Log Summary: Specify contents for DICOMDIR records Type of Modification Modification Rationale for Correction Name of

More information

DICOM SR. DICOM Structured Reporting and templates. Herman Oosterwijk, OTech Inc. Connectivity training and consulting.

DICOM SR. DICOM Structured Reporting and templates. Herman Oosterwijk, OTech Inc. Connectivity training and consulting. DICOM Structured Reporting and templates Herman Oosterwijk, OTech Inc. Connectivity training and consulting www.otechimg.com SPIE 2001 slide A 1-1 Agenda: SR structure SR templates (Note: D. Clunie s book

More information

DICOM Correction Proposal

DICOM Correction Proposal DICOM Correction Proposal STATUS Final Text Date of Last Update 2016/05/25 Person Assigned Submitter Name Ulrich Busch (ulrich.busch@varian.com) Ulrich Busch (ulrich.busch@varian.com) Submission Date 2015/09/16

More information

19 CP Replace uses of "data set" that do not refer to the PS3.5 defined meaning

19 CP Replace uses of data set that do not refer to the PS3.5 defined meaning 19 CP-1817 - Replace uses of "data set" that do not refer to the PS3.5 defined meaning Page 1 1 Status Assigned 2 Date of Last Update 2018/06/04 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com

More information

13 CP Addition of Measurement Report Root Template for Planar and Volumetric ROIs

13 CP Addition of Measurement Report Root Template for Planar and Volumetric ROIs 13 CP-1386 - Addition of Measurement Report Root Template for Planar and Volumetric ROIs Page 1 1 STATUS Final Text 2 Date of Last Update 2014/11/11 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT g GE Medical Systems Technical Publications Direction 5146235-100 Revision 3 Reporting Tool DICOM Copyright 2005-2006 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK i REVISION

More information

19 CP Remove description of retired Big Endian Transfer syntax

19 CP Remove description of retired Big Endian Transfer syntax 19 CP-19 - Remove description of retired Big Endian Transfer syntax Page 1 1 Status Letter Ballot Date of Last Update 016/0/18 Person Assigned David Clunie mailto:dclunie@dclunie.com Submitter Name David

More information

19 CP Remove description of retired Big Endian Transfer syntax

19 CP Remove description of retired Big Endian Transfer syntax 19 CP-19 - Remove description of retired Big Endian Transfer syntax Page 1 1 Status Final Text Date of Last Update 016/0/ Person Assigned David Clunie mailto:dclunie@dclunie.com Submitter Name David Clunie

More information

26 CP Retire DICOMDIR reference to unencapsulated CDA on media

26 CP Retire DICOMDIR reference to unencapsulated CDA on media 26 CP-765 - Retire DICOMDIR reference to unencapsulated CDA on media Page Status Assigned 2 Date of Last Update 207/2/22 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter Name David

More information

13 CP Addition of Measurement Report Root Template for Planar and Volumetric ROIs

13 CP Addition of Measurement Report Root Template for Planar and Volumetric ROIs 13 CP-1386 - Addition of Measurement Report Root Template for Planar and Volumetric ROIs Page 1 1 STATUS Letter Ballot 2 Date of Last Update 2014/09/08 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com

More information

DICOM Correction Proposal Form

DICOM Correction Proposal Form DICOM Correction Proposal Form Tracking Information - Administration Use Only Correction Proposal Number CP-199 STATUS Sep 2001 Voting Packet Date of Last Update 2001/06/20 Person Assigned David Clunie

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications 2391078-2-800 Revision 1 Seno Advantage2 WorkStation for DICOM V3.0 do not duplicate Copyright 2006 By General Electric Co. THIS PAGE LEFT INTENTIONALLY BLANK REVISION

More information

22 CP Value Representation corrections related to OL, UC and UR

22 CP Value Representation corrections related to OL, UC and UR 22 CP-1544 - Value Representation corrections related to OL, UC and UR Page 1 1 Status Letter Ballot 2 Date of Last Update 2016/03/18 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT g GE Medical Systems Technical Publications Direction 5215475-100 Revision 1 Reporting Tool DICOM Copyright 2005-2007 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK i REVISION

More information

DICOM Correction Proposal Form

DICOM Correction Proposal Form DICOM Correction Proposal Form Tracking Information - Administration Use Only Correction Proposal Number STATUS CP-1418 Assigned Date of Last Update 2016.03.17 Person Assigned Submitter Name Kevin O Donnell

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes

Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes Page 1 4 Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes 8 12 16 20 Status: Proposed Final Text Feb 30, 2000 (Subject to 30-day letter approval)

More information

36 CP Update AIM to DICOM SR TID 1500 mapping with model revisions

36 CP Update AIM to DICOM SR TID 1500 mapping with model revisions 36 CP-1779 - Update AIM to DICOM SR TID 1500 mapping with model revisions Page 1 1 Status Final Text 2 Date of Last Update 2019/01/21 3 Person Assigned David Clunie 4 mailto:dclunie@dclunie.com 5 Submitter

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 101: HL7 Structured Document Object References

Digital Imaging and Communications in Medicine (DICOM) Supplement 101: HL7 Structured Document Object References Digital Imaging and Communications in Medicine (DICOM) Supplement 0: HL7 Structured Document Object References Prepared by: DICOM Standards Committee, Working Group 20 and Working Group 8 300 N. 7th Street

More information

R2 Cenova 1.2. DICOM Conformance Statement. MAN Rev 001

R2 Cenova 1.2. DICOM Conformance Statement. MAN Rev 001 R2 Cenova 1.2 DICOM Conformance Statement MAN-001104 Rev 001 Mammography R2 Cenova 1.2 DICOM Conformance Statement PN MAN-01104 Rev 001 Technical Support For support in North America contact: Toll Free:

More information

IHE Eye Care Technical Framework Supplement. Key Measurements in DICOM Encapsulated PDF. Revision 1.0 Draft for Public Comment

IHE Eye Care Technical Framework Supplement. Key Measurements in DICOM Encapsulated PDF. Revision 1.0 Draft for Public Comment Integrating the Healthcare Enterprise 5 IHE Eye Care Technical Framework Supplement 10 Key Measurements in DICOM Encapsulated 15 Revision 1.0 Draft for Public Comment 20 Date: January 22, 2019 Author:

More information

Radiation Dose Structured Reports

Radiation Dose Structured Reports AAPM Annual Meeting 2013 Imaging Informatics 2 Radiation Dose Structured Reports David Clunie (dclunie@dclunie.com) PixelMed Publishing RDSR Learning Objectives l Basic concepts of DICOM structured reporting

More information

DICOM Correction Proposal

DICOM Correction Proposal DICOM Correction Proposal STATUS Draft Date of Last Update 2018/06/26 Person Assigned Don van Syckle Submitter Name Submission Date 2018/03/09 Patrick A. Nast (patrick.nast@zeiss.com) Correction Number

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-668 Log Summary: Type of Modification Addition Name of Standard PS 3.3, 3.17 2006 Rationale for Correction The term axial is common in practice, but is incorrectly

More information

DICOM Correction Proposal Form

DICOM Correction Proposal Form DICOM Correction Proposal Form Tracking Information - Administration Use Only Correction Proposal Number CP- 136 STATUS Draft Date of Last Update October 26, 1998 Person Assigned Submitter Name Harry Solomon

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-567 Log Summary: Type of Modification Clarification Name of Standard PS 3.3 2004 Rationale for Correction The order of signficance of dimension indices (i.e.,which

More information

DICOM Correction Proposal

DICOM Correction Proposal 1 DICOM Correction Proposal STATUS Letter Ballot Date of Last Update 2016/03/16 Person Assigned Submitter Name Jim Philbin Kinson Ho Submission Date 2015/05/25 Correction Number

More information

ATC Conformance Statement Overview

ATC Conformance Statement Overview Advanced-Technology QA Consortium DICOM Workshop: ATC Conformance Statement Overview Walter R. Bosch, D.Sc. ATC DICOM Conformance Statement Overview DICOM Part 10 File Set Reader Application (ITC) Defines

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-465 Log Summary: Type of Modification Correct Name of Standard PS3.3-2004, PS3.6-2004, PS3.16-2004 Rationale for Correction: Ultrasound can be used to characterize

More information

Atlas-Based Autosegmentation. DICOM Conformance Statement DICOM 3.0

Atlas-Based Autosegmentation. DICOM Conformance Statement DICOM 3.0 DICOM Conformance Statement DICOM 3.0 Revision History, Trademarks ABAS DICOM Conformance Statement Revision History Revision Date Changes ABAS_DCS_100_A 04/2008 First version. ABAS_DCS_B 04/2009 Update

More information

DICOM Correction Proposal

DICOM Correction Proposal DICOM Correction Proposal STATUS Assigned Date of Last Update 2016/11/01 Person Assigned Ulrich Busch (ulrich.busch@varian.com) Submitter Name Submission Date 2016/09/15 Ulrich Busch (ulrich.busch@varian.com)

More information

IHE Cardiology Technical Framework Supplement. Evidence Documents Profile. Cardiology Options: Stress Testing CT/MR Angiography

IHE Cardiology Technical Framework Supplement. Evidence Documents Profile. Cardiology Options: Stress Testing CT/MR Angiography Integrating the Healthcare Enterprise 5 IHE Cardiology Technical Framework Supplement Evidence Documents Profile 10 Cardiology Options: Stress Testing CT/MR Angiography 15 Trial Implementation Date: October

More information

DICOM Correction Item

DICOM Correction Item : Letter Ballot DICOM Correction Item Correction Number CP-407 Log Summary: Type of Modification Modification Name of Standard PS 3.4 2003 Rationale for Correction: The service status classes specified

More information

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Workflow (TDW) Draft for Public Comment

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Workflow (TDW) Draft for Public Comment Integrating the Healthcare Enterprise IHE Radiation Oncology Technical Framework Supplement Treatment Delivery Workflow (TDW) Draft for Public Comment Date: January 29, 2010 Author: David Murray Email:

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications Direction 2391078-5-8EN Revision 1 Seno Advantage 2.0 WorkStation do not duplicate Copyright 2011 By General Electric Co. THIS PAGE LEFT INTENTIONALLY BLANK Page

More information

Supplement 207 Conformity Assessment

Supplement 207 Conformity Assessment Supplement 207 Conformity Assessment WG-31 Conformance, May 2018 Contents What did we achieve so far [WG-06]? [Nov-17] DICOM Conformity Assessment Model [Nov-17] Definitions for conformance based on OASIS

More information

Deep dive into SR: Key Object Selection and Radiation Dose Report

Deep dive into SR: Key Object Selection and Radiation Dose Report THE DICOM 2013 INTERNATIONAL CONFERENCE & SEMINAR March 14-16 Bangalore, India Harry Solomon Deep dive into SR: Key Object Selection and Radiation Dose Report Interoperability Architect, GE Healthcare

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Application Annex: Ultrasound Viewer on Xcelera R3.2L1 SP2 Koninklijke Philips Electronics N.V. 2011 All rights are reserved. Document Number: PIIOffc.0000085 Issued by: Philips

More information

Delta 4. DICOM Conformance Statement D (7)

Delta 4. DICOM Conformance Statement D (7) Delta 4 DICOM Conformance Statement D001 32 005 01 1 (7) 1 Introduction 1.1 Purpose This conformance statement specifies how the Delta 4 application conforms to the DICOM v3.0 standard. Delta4 uses DICOM

More information

DICOM Correction Proposal Form

DICOM Correction Proposal Form DICOM Correction Proposal Form STATUS Letter Ballot Date of Last Update 2014/11/12 Person Assigned Submitter Name Rob Horn Rob Horn Submission date 27 Jan 2014 Correction Number CP- 1031 Log Summary: Support

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities sup17_13_newrtradiations.doc: Sup 17: nd Generation RT Additional RT Treatment Modalities Page 1 Digital Imaging and Communications in Medicine (DICOM) Supplement 17: Second Generation Radiotherapy Additional

More information

Exemplary Design of a DICOM Structured Report Template for CBIR Integration into Radiological Routine

Exemplary Design of a DICOM Structured Report Template for CBIR Integration into Radiological Routine Exemplary Design of a DICOM Structured Report Template for CBIR Integration into Radiological Routine Petra Welter* a, Thomas M. Deserno a, Ralph Gülpers a, Berthold B. Wein b, Christoph Grouls c, Rolf

More information

Technical Publications

Technical Publications GE Medical Systems Technical Publications Direction 2188003-100 Revision 0 Tissue Volume Analysis DICOM for DICOM V3.0 Copyright 1997 By General Electric Co. Do not duplicate REVISION HISTORY REV DATE

More information

DICOM Conformance Statement for GALILEI. Software Version V6.0

DICOM Conformance Statement for GALILEI. Software Version V6.0 DICOM Conformance Statement for GALILEI Software Version V6.0 Version 1.0, December 6 th, 2011 Contents Revision History... 2 Purpose... 2 References... 2 Terms and Definitions... 2 Abbreviations... 3

More information

DICOM Conformance Statement

DICOM Conformance Statement Visante AC-OCT Version 3.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com P/N: 2660021134750 Rev: C 9/03/2009 Page 1 of 22 1 Conformance Statement Overview This

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Application Annex: HeartNavigator R2.0.5 Koninklijke Philips N.V. 2015 All rights are reserved. Document Number: ICAP-PF.0015391 Issued by: Philips Medical Systems Nederland

More information

Generating XML Schemas for DICOM Structured Reporting Templates

Generating XML Schemas for DICOM Structured Reporting Templates 72 ZHAO ET AL, XML Schemas for DICOM SR Templates Research Paper j Generating XML Schemas for DICOM Structured Reporting Templates LUYIN ZHAO, MS,KWOK PUN LEE, PHD, JINGKUN HU, DPS Abstract In this paper,

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities sup176_pc_newrtradiations.doc: Sup 176: 2 nd Generation RT Additional RT Treatment Modalities Page 1 2 4 Digital Imaging and Communications in Medicine (DICOM) 6 Supplement 176: Second Generation Radiotherapy

More information

Punctual Dicom Workstation

Punctual Dicom Workstation DICOM Conformance Statement Punctual Dicom Workstation Company Name Product Name Product Version 2.0 Document number 2008-1001 Date June 1, 2009 Punctual Software Inc. Punctual Dicom Workstation TABLE

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-776 Log Summary: Type of Modification Correction Name of Standard PS 3.3 2007 Rationale for Correction For some time it has been the convention not to make attributes

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-601 Log Summary: Type of Modification Addition Name of Standard PS 3.4 2006 + CP 620 Rationale for Correction Several aspects of matching during queries are either

More information

Conformance Assertions, Test Scenarios, Test Cases, Conformity Assessment Report,

Conformance Assertions, Test Scenarios, Test Cases, Conformity Assessment Report, Conformance Assertions, Test Scenarios, Test Cases, Conformity Assessment Report, WG-31 Conformance, October 2017 Contents Overview Levels Verification structure Extending the content Physical test cases

More information

Merge CADstream TM V. 6.2

Merge CADstream TM V. 6.2 Merge CADstream TM V. 6.2 DICOM CONFORMANCE STATEMENT Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA Copyright 2017 Merge Healthcare Incorporated, an IBM Company. U.S. GOVERNMENT RESTRICTED

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 189: Parametrical Blending Presentation State Storage

Digital Imaging and Communications in Medicine (DICOM) Supplement 189: Parametrical Blending Presentation State Storage 5 Digital Imaging and Communications in edicine (DICO) Supplement 189: Parametrical Blending Presentation State Storage 10 15 Prepared by: DICO Standards Committee, Working Group 16 (R sub group Functional

More information

DICOM Correction Proposal

DICOM Correction Proposal DICOM Correction Proposal STATUS Final Text Date of Last Update 2017/09/17 Person Assigned Submitter Name Ulrich Busch (ulrich.busch@varian.com) Ulrich Busch (ulrich.busch@varian.com) Submission Date 2016/05/03

More information

DICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG

DICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG Document Revision 3 July 6, 2016 2016 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software ExacTrac. The DICOM import part of the application

More information

QAngio XA 7.0. DICOM Conformance Statement

QAngio XA 7.0. DICOM Conformance Statement QAngio XA 7.0 DICOM Conformance Statement February 15, 2006 V1.0 FINAL Legal Notices Copyright Notice 2003-2006 Medis medical imaging systems bv. All rights reserved. Unless otherwise indicated, this manual

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities Modalities Page 1 2 4 Digital Imaging and Communications in Medicine (DICOM) 6 Supplement 176: Second Generation Radiotherapy Additional RT Treatment Modalities 8 10 12 14 16 DICOM Standards Committee,

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 194: RESTful Services for Non-Patient Instances

Digital Imaging and Communications in Medicine (DICOM) Supplement 194: RESTful Services for Non-Patient Instances 1/20/2016 3:37 PM Supplement XXX: Non-Patient Instances RESTful Service Page 1 5 10 Digital Imaging and Communications in Medicine (DICOM) Supplement 194: RESTful Services for Non-Patient Instances 15

More information

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Record Content (TDRC) Revision 1.0 Draft for Public Comment

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Record Content (TDRC) Revision 1.0 Draft for Public Comment Integrating the Healthcare Enterprise 5 IHE Radiation Oncology Technical Framework Supplement 10 Treatment Delivery Record Content (TDRC) 15 Revision 1.0 Draft for Public Comment 20 Date: November 15,

More information

TrueBeam Imaging Release 2.7 MR 2. DICOM Conformance Statement

TrueBeam Imaging Release 2.7 MR 2. DICOM Conformance Statement TrueBeam Imaging Release 2.7 MR 2 DICOM Conformance Statement P/N P1026001001-A December 2017 General Information Abstract This document provides information about the DICOM Conformance of the TrueBeam

More information

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement 2.1 Document Revision 2 April 13, 2011 2011 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software.

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement TOPCON Corporation TOPCON SPECULAR MICROSCOPE SP-1P Version 1.10 Document Version: 1 Date: 2014-02-17 1 CONFORMANCE STATEMENT OVERVIEW This document declares conformance to

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement. UNIQ Release 1.0 Koninklijke Philips N.V. 2016 All rights are reserved. ICAP-T-030001.09b Corresponds to ICAP-W-030001.02 Issued by: Philips Medical Systems Nederland BV, a

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement McKesson Cardiology Release 13.2.1 June 2016 Doc ID DCM-10018 Doc Revision 1.0 Produced in Cork, Ireland Revision History Revision Revision Date Summary of Changes Rev. 1.0

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Product Version: COMPASS 1.0 Document Version: 1.01 Status: Released Internal Document Number: P-05-008-510-002 Date: 2007-10-02 1 39 Issued By (Distributor): IBA Dosimetry

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex

Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex 5 Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex 10 15 Prepared by: DICOM Standards Committee, Working Group 2, Projection Radiography

More information

DICOM Correction Proposal

DICOM Correction Proposal DICOM Correction Proposal STATUS New Date of Last Update 2015/11/09 Person Assigned Jim Philbin (james.philbin@jhmi.edu) Submitter Name Jim Philbin (james.philbin@jhmi.edu) Submission Date 2015/09/13 Correction

More information

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL

More information

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL

More information

AVIA (Dx MM) DICOM 3.0 Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) is a product of Medasys Digital Systems. Table of Contents 1INTRODUCTION... 4 1.1SCOPE AND AUDIENCE... 4 1.2REFERENCES... 4 1.3ACRONYMS AND ABBREVIATIONS...

More information

DICOM Conformance Statement

DICOM Conformance Statement 10.01.80.01 Rev. 03 Customer Information Bulletin Title DICOM Conformance Statement Scope Rogan View Pro-X Target Group Service Engineers Page 2 of 2 CIB 10.01.80.01 Rev. 03 How To Contact Rogan-Delft

More information

Infinity Medical Soft, Inc ,Higashinaganuma,Inagishi, Tokyo JAPAN

Infinity Medical Soft, Inc ,Higashinaganuma,Inagishi, Tokyo JAPAN DICOM 3.0 Conformance Statement MIE-IAS v 8.1(.Net Version) Part number: 0300001-0001 02/05/2003 Weiping-Ren Part number: 0401001-0001 10/11/2003 Makoto-Okazaki Part number: 0402003-0001 01/30/2004 Makoto-Okazaki

More information

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be disclosed or reproduced in whole or in part, without

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 121: CT Protocol Storage

Digital Imaging and Communications in Medicine (DICOM) Supplement 121: CT Protocol Storage DICOM Supplement 121 : CT Protocol Storage Page 1 2 4 6 Digital Imaging and Communications in Medicine (DICOM) 8 Supplement 121: CT Protocol Storage 10 12 14 16 18 20 Prepared by: 22 DICOM Standards Committee,

More information

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F DICOM Conformance Statement ***** FDR-1000AWS CR-IR363AWS for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage (Standard) August, 2010

More information

Sidexis 4 with Sidicom RM

Sidexis 4 with Sidicom RM Sidexis 4 with Sidicom RM (RM = Removable Media) Version 2.0 Released 08/10/2017 for product versions from 4.0 onwards Copyright 2017 Sirona Dental Systems GmbH - All rights reserved. Page 1 of 11 Contents

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Application Annex: CT Applications on Philips IntelliSpace Portal V6.0 Koninklijke Philips Electronics N.V. 2013 All rights are reserved. Document Number: PIIOffc.0001074.02

More information

DICOM Conformance Statement RadWorks 2.1 Product Line

DICOM Conformance Statement RadWorks 2.1 Product Line RadWorks 2.1 Product Line Author : Frank Wessels Revision Date : August 1997 Version : 2.1a Document Number : 1996-1997 Applicare Medical Imaging B.V. Name Signature Date Consulting Radiologist Frits Barneveld-

More information

DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:

DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number: DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number: 0000062023 ImageWorks 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (914) 592-6100 1 Revision History Version

More information

MediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English

MediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English MediaWorkStation MWS DICOM Push Interface Version 2.0 DICOM Conformance Statement English 1-2014 Abbreviations AE DICOM IE IOD MPPS MWL MWS PACS PDU SOP SCP SCU Application Entity Digital Imaging and Communication

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 189: Parametrical Blending Presentation State Storage.

Digital Imaging and Communications in Medicine (DICOM) Supplement 189: Parametrical Blending Presentation State Storage. 2 4 6 Digital Imaging and Communications in Medicine (DICOM) 8 Supplement 189: Parametrical Blending Presentation State Storage 10 12 14 16 Prepared by: 18 DICOM Standards Committee, Working Group 16 (MR

More information

SCORE 3D Workstation DICOM CONFORMANCE STATEMENT

SCORE 3D Workstation DICOM CONFORMANCE STATEMENT Document No.: S517-E105 Revision No.: A DIGITAL ANGIOGRAPHY SYSTEM DAR-9500f SCORE 3D Workstation DICOM CONFORMANCE STATEMENT Revision History Rev. Date Content of Change First 2013.09 Newly issued. A

More information

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5 ClearCanvas Workstation DICOM Conformance Statement Document Version: 1.5 Product Name(s): Release: ClearCanvas Workstation 2.0 SP1 Date: February 22, 2010 1 CONFORMANCE STATEMENT OVERVIEW 1.1 OVERVIEW

More information

Uscan. DICOM Conformance Statement

Uscan. DICOM Conformance Statement DICOM Conformance Statement - Uscan Uscan DICOM Conformance Statement Software Version: 4.1.1 Date: 3 August 2018 Signostics, Inc., a subsidiary of EchoNous, Inc. 8310 154th Ave NE, Suite 200 Redmond,

More information

Galileo CAD. DICOM Conformance Statement Version Copyright by ARCADIA LAB srl

Galileo CAD. DICOM Conformance Statement Version Copyright by ARCADIA LAB srl Galileo CAD DICOM Conformance Statement Version 1.01 Copyright 2005-2006 by ARCADIA LAB srl 1 1 Introduction... 3 1.1 Scope and Field of Application... 3 1.2 Revision History... 3 1.3 Acronyms... 3 1.4

More information

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration Positron Emission Tomography (PET) Technical Information Software Version 9.1 1 DICOM CONFORMANCE STATEMENT OVERVIEW 1.1

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT Document No.: S517-1087 Revision: B DAR-7500 DICOM CONFORMANCE STATEMENT MEDICAL SYSTEMS DIVISION Revision History History Date Revision Description 1 st Edition July 2007 - A July.2008 Entirely recreated.

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement SCENARIA Tokyo, Japan E1E-HC0002-01 Hitachi, Ltd. 2016. All rights reserved. History Revision Description Date Rev. 1.0 Initial. 2016/04/01 ii E1E-HC0002 Contents History...

More information

KARL STORZ OR1 FUSION V1.3.1 DICOM Conformance Statement

KARL STORZ OR1 FUSION V1.3.1 DICOM Conformance Statement KARL STORZ OR1 FUSION V1.3.1 DICOM Conformance Statement PRODUCT INFO OR1 OR1 87 1.2 02/2018/PI-E 1/21 1 Table of Content 1 Abbreviations...3 1.1 Definitions...3 1.2 References...3 2 CONFORMANCE STATEMENT

More information

DICOM Conformance Statement

DICOM Conformance Statement BK Ultrasound DICOM Conformance Statement For bkhub (Software Version 3.0.0 and higher) Ultrasonix Medical Corporation 130 4311 Viking Way Richmond, BC V6V 2K9 Canada www.bkultrasound.com support@bkultrasound.com

More information

Technical Publication. DICOM Conformance Statement. iplan RT Dose 4.1. Document Revision 1. December 4, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. iplan RT Dose 4.1. Document Revision 1. December 4, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement iplan RT Dose 4.1 Document Revision 1 December 4, 2008 2008 Copyright BrainLAB AG IPlan RT Dose 4.1 1 Conformance Statement Overview This document details

More information

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG Technical Publication DICOM Conformance Statement Document Revision 11 May 18, 2017 2017 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software

More information

Whole Body X-ray CT System Supria. DICOM Conformance Statement

Whole Body X-ray CT System Supria. DICOM Conformance Statement Whole Body X-ray CT System Supria DICOM Conformance Statement Tokyo, Japan (SN-C633E) Copyright Hitachi Medical Corporation. 2013, 2014. All rights reserved. History Revision Description Date Rev. 1.0

More information

efx Software DICONDE Conformance Statement

efx Software DICONDE Conformance Statement efx Software DICONDE Conformance Statement Version 1.2 9/29/2015 North Star Imaging, Inc. 1 DICOM conformance statement overview The North Star Imaging s efx Software is an imaging viewing software with

More information

ASTRO Integrating the Healthcare Enterprise. IHE-Radiation Oncology Technical Framework Volume 2 - Transactions

ASTRO Integrating the Healthcare Enterprise. IHE-Radiation Oncology Technical Framework Volume 2 - Transactions ASTRO Integrating the Healthcare Enterprise IHE-Radiation Oncology Technical Framework Volume 2 - Transactions 2008 November 13, 2008 Copyright 2006-2008: ACC/HIMSS/RSNA/ASTRO Contents 1 Preface to Volume

More information