Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com
|
|
- Dulcie Robertson
- 6 years ago
- Views:
Transcription
1 Lever Your Genius Spectrograph & Accessories Datasheet
2 FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has its own specially designed ecosystem of accessories, including elegant light-coupling CUBES, laser sources, fiberoptics, and beautifully designed software. FERGIE DATASHEET Highlights Aberration-Free Design No coma, no astigmatism at all wavelengths. Comparison of spectral data from the optical design of a standard 3 mm Czerny Turner spectrometer and FERGIE. Mercury spectral lines to show aberration-free optical performance of FERGIE. FERGIE Ecosystem FERGIE is much more than a spectrograph. It s meticulously engineered ecosystem includes CUBEs, lasers, probes, fiberoptics and more... FERGIE Software While FERGIE successfully distinguishes itself with innovative hardware, the beautifully designed software orchestrates all inner workings and makes it a pleasure to use the system day in and day out! 2
3 FERGIE DATASHEET The FERGIE compact, imaging spectrograph addresses many spectral ranges lab notebook! A plurality of complex experiments for a wide range of Raman spectrum experiment that used to take hours to set up now can be completed in fewer than 9 seconds. FERGIE compares well with longer focal length, physically larger spectrographs spectroscopy, with wavelength coverage ranges from 2-11 nm. For out of the box experience, FERGIE comes fully acclaimed LightField package. FEATURE Custom, aberration-free optical design BENEFITS in all other mirror based spectrographs results in broadened asymmetric Perfect imaging performance Enabling line of accessories Integrated TE cooled, back-illuminated CCD FERGIE s proprietary optical design produces diffraction limited images ideal for microspectroscopy applications at wavelengths ranging from the UV to NIR. Instruments modular spectroscopy cubes. Spectroscopy cubes enable rapid experiment design with minimal alignment. down to -55 C allows long integration times for detecting faint signals. Frame transfer CCD architecture High speed frame transfer CCD detector captures full frame images at 34 frames/sec and spectral rates over 1 khz (binning 1 rows). Internal FPGA-based timing generator FERGIE s internal timing generator with 1 ns resolution makes time resolved spectroscopy nearly turnkey. Two pulse width and delay outputs and one Kinetics spectroscopy mode FERGIE software powered by LightField Windows 1/8/7, 64 bit High speed USB 3. interface. microsecond time resolution. Flexible and intuitive software for data acquisition and analysis is included with FERGIE delivering a complete solution that works right out of the box. Plug-and-play operation with desktop work stations or laptops Time-Resolved Spectroscopy, Fluorescence, and more. reva3.3 3
4 FERGIE DATASHEET Specs FERGIE Specs Model FER-SCI-BRX FER-SCI-BX Sensor type Sensor format Focal length 8.8 Aperture ratio f/4 Spectral resolution (FWHM)* Usable wavelength range Single-exposure wavelength range Spatial resolution Grating mount Astigmatism/coma aberation Slits Wavelenth accuracy* Wavelenth repeatability* Deepest cooling temperature System read noise PI proprietary back-illuminated, deep depletion, frame transfer sensor with excelon and UV coating 124 x 256 (124 x 512 including frame-transfer storage area) nm at all points in the focal plane 4-11 nm with VIS-NIR option 2-11 nm with UV-NIR option See Ordering Information for more details 54 nm with 295 g/mm grating 268 nm with 6 g/mm grating 135 nm with 12 g/mm grating Entire usable range is accessible using computer-controlled, rotatable grating % contrast over entire focal plane (Nyquist limited) Interchangable, rotatable single-grating turret Zero at all wavelengths, grating angles over entire focal plane 1, 25, 5, 1, 15, 2, 3, 5 μm; 3.3 mm tall Interchangeable, laser-cut slits.26 nm.13 nm 55 C guaranteed, 6 C typical 1 e- 1 MHz Maximum integration time** 4 minutes Hours PI proprietary back-illuminated, frame transfer sensor with excelon and UV coating Vertical shift rate 5.6 μsec/row to 35 μsec/row (programmable) 15.2 μsec/row to 95 μsec/row (programmable) Spectral rate (continuous) 292 spectra/sec (full vertical bin) 124 spectra/sec (full vertical bin) Spectral rate (burst mode) >1, spectra/sec (spectral kinetics mode with 1 rows binned) Non-linearity Software selectable gains Data interface I/O signals Operating environment Certification 1 MHz 1.5 e-/adu, 3 e-/adu (typical) Available at all ADC rates USB 3. (3 m interface cable provided) Three MCX coaxial connectors: two trigger out, one trigger in Built-in programmable pulse generator +5 C to +3 C non-condensing CE Dimensions L x W x H 26.8 cm x 18. cm x 21. cm (11 x 7 x 8 ) >5, spectra/sec (spectral kinetics mode with 1 rows binned) *with nm **At -55 C, 5% full well capacity at low gain with 1 rows binning ALL SPECIFICATIONS SUBJECT TO CHANGE. SPECIFICATIONS ARE TYPICAL EXCEPT WHERE NOTED. 4
5 FERGIE DATASHEET Outlines & QE FERGIE Outline Drawings FRONT PANEL (Light Entrance Port) BACK PANEL [15.].591 [15.] REMOVEABLE ENTRANCE SLIT X #4-4 TAPPED HOLES INTERNAL SHUTTER ACCESS PANEL ADJUSTABLE FEET FERGIE Quantum Efficiency 1% 9% 8% 7% Quantum cy (%) 6% 5% 4% 3% 2% 1% % BRX Back-Illuminated Deep-Depletion BX Back-Illuminated NOTE: Quantum effieciency curves for excelon CCDs with UV enhancement coatings. All FERGIE models have excelon and UV coating included. Wavelength (nm) 5
6 FERGIE DATASHEET CUBES & Accessories FERGIE CUBES With FERGIE CUBES, interfacing is a cinch! If you ve ever spent more time digging through cabinets than conducting your actual experiment, you ll definitely appreciate these CUBES. Designed for free space and fiber coupling Pre-aligned (stays aligned as more CUBES are added) Easy to attach using only a screwdriver Compatible with Thorlabs 3 mm cage system The following is an initial list of CUBES available with FERGIE. Be sure to check out as more CUBES will be added in the future. CUBE 1: Focusing CUBE 2: 785 nm Raman Filter CUBE 3: Sample Chamber Houses an f/4 achromatic doublet lens with precision focusing and translation adjustment to bring light into FERGIE on-axis every time. Contains a pre-aligned Princeton Instruments dichroic beam splitter (127 cm -1 edge) with a matching OD 6 edge filter and a built-in laser line filter. Raman is now turnkey! A four-port, two-lens sample chamber designed to house a 12.5 mm cuvette makes measuring liquid-phase samples a breeze. Ideal for Raman, absorbance, and fluorescence spectroscopy. CUBE 4: Beam Splitter CUBE 5: Filter Contains a precision-aligned 5:5, 7:3, or 9:1 beam splitter cube. Ideal for introducing a witness camera, additional laser line, or absorbance reference line to the optical path. No alignment is necessary. Just connect! Contains an indexing linear slide capable of housing four 1/2 inch diameter filters. Ideal for inserting order-sorting or band-limiting filters into your optical design. FERGIE Accessories FERGIE is compatible with a multitude of lasers, fiberoptics, probes and calibration light sources. With optional wavelength (Hg/Ne-Ar) and intensity (QTH) calibration light sources, it s never been easier to acquire accurate and repeatable spectral data. Our new FERGIE software automates the entire calibration procedure to achieve peer-review worthy data within a matter of minutes. Say goodbye to manual, post-acquisition data corrections forever! Wavelength Calibration Intensity Calibration FC fiber terminal 1/2 diameter order-sorting filter USB computer control USB computer control 785 nm laser 6
7 FERGIE Parts List Part Number Description FER-SCI-BX FERGIE DATASHEET Parts List FERGIE spectrograph: BX back-illuminated excelon sensor; CUBE1; SLIT; GRT FER-SCI-BRX FER-CAL-WL FER-CAL-QTH FER-CUBE FER-CUBE1-UV FER-CUBE1-VIS FER-CUBE1-NIR FER-CUBE2-785 FER-CUBE3 FER-CUBE4-5 FER-CUBE4-7 FER-CUBE4-9 FER-CUBE5 FERGIE spectrograph: BRX back-illuminated, deep depletion excelon sensor; CUBE1; SLIT; GRT Ne/Hg-Ar wavelength-calibration reference lamp QTH calibration lamp Basic CUBE: top/bottom plates for mounting optics Focusing CUBE: optimized for UV ( nm) Focusing CUBE: optimized for VIS (4 7 nm) Focusing CUBE: optimized for NIR (65 15 nm) Raman Filter CUBE: laser line; dichroic; edge filters Sample Chamber CUBE: 2 lenses; 4 optical ports Beam Splitter CUBE: 5:5; non-polarizing Beam Splitter CUBE: 7:3; non-polarizing Beam Splitter CUBE: 9:1; non-polarizing Filter CUBE: 4-position linear slide for ½ inch OD filters Lasers FER-LAS-785 FERGIE wavelength-stabilized multimode laser Fiberoptics FER-PROBE- 785RAM FER-FIBER-LIN FER-FIBER-BI-LIN FER-FIBER-LAS FER-FIBER-PTH FER-FP-VIS FER-FP-NIR FERGIE 785 nm Raman probe FERGIE linear fiber array: fifty 5 µm fibers; 3 mm tall FERGIE bifurcated fiber to linear array: 1.5 x 2 mm tall FERGIE FC/PC: 15 µm fiber for laser excitation FERGIE FC/PC: 4 µm patch cable FERGIE fiber port: couples VIS light into CUBES FERGIE fiber port: couples NIR light into CUBES Slits FER-SLIT FERGIE slit: 1, 25, 5, 1, 15, 2, 3, 5 µm; 3.3 mm tall Gratings FER-GRT FERGIE grating: mounted and field replaceable; 295 g/mm to 36 g/mm Enquire with factory for additional parts 7
8 FERGIE DATASHEET Ordering Ordering Information Ordering FERGIE is as easy as 1, 2, 3! Select sensor type: BRX Select wavelength range: VIS-NIR Select grating: Choose default grating BRX: back-illuminated, deep depletion, excelon sensor Higher resolution Faster spectral rate Superior sensitivity in infrared (75-11 nm) What s in the box? Usable wavelength range: 4 11 nm Protected silver optics for best throughput No sensitivity below 4 nm or or BX UV-NIR BX: back-illuminated excelon sensor Lower dark current Usable wavelength range: nm Protected aluminum optics Larger accesible wavelength range Less throughput from 4-11 nm Grooves / mm Blaze Wavelength (nm) Part Number FER-GRT FER-GRT FER-GRT FER-GRT FER-GRT FER-GRT FER-GRT Optional Accessories: Atomic light source for wavelength calibration Quartz tungsten halogen (QTH) lamp for intensity calibration Field-replaceable gratings Slits Lasers Fiberoptics FERGIE CUBES Need help? Send a message to info@ and a friendly Princeton Instruments representative will be in touch with you shortly! Contact your sales represenatative to discuss other grating options. Manual CUBE1-VIS 8
9 Princeton Instruments - New Jersey 366 Quakerbridge Road Trenton, NJ 8619 USA Tel: Fax: info@princetoninstruments.com Princeton Instruments - Massachusetts 15 Discovery Way Acton, MA 172 USA Tel: Fax: info@princetoninstruments.com China Princeton Instruments - China Shanghai Office Room 61, CENTRAL TOWERS 567 Lan Gao Road Shanghai, 2333 Tel: Mobile: info_china@princetoninstruments.com France Roper Scientific, SAS Z.I. Petite Montagne Sud LISSES 8 rue de Forez - C.E. 172 F-9117 Evry Cedex, France Tel: Fax: info@roperscientific.fr Germany Roper Scientific, GmbH Einsteinstraße 39a D Planegg / Martinsried - Germany Tel: + 49 () Fax: + 49 () contactus@roperscientific.de Japan PI - Japan Regional Office Nippon Roper, K. K. Sakurai Building Fukagawa, Kotu-Ku Tokyo , JAPAN Tel: Fax: web_pi_contact@roper.co.jp United Kingdom Princeton Instruments, UK 25 Nuffield Way Abingdon, Oxfordshire OX14 1RL Tel: +44 () info_uk@princetoninstruments.com Lever Your Genius
Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com
Lever Your Genius Spectrograph & Accessories Datasheet FERGIE DATASHEET Highlights 2 FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has
More informationLever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com
Lever Your Genius Spectrograph & Accessories Datasheet FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has its own specially designed ecosystem
More informationPIXIS: 512 IMAGING GROUP
PIXIS: 512 Now Powered with LightField The PIXIS: 512 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras designed expressly for quantitative scientific imaging applications.
More informationMinimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.
Now Powered by LightField PyLoN:100 1340 x 100 The PyLoN :100 is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible
More informationSOPHIA 2048B. Datasheet ULTRA-LOW-LIGHT, LOW-NOISE UV / VIS CAMERAS LARGE-FORMAT CCD CAMERAS
SOPHIA 2048B LARGE-FORMAT CCD CAMERAS Datasheet ULTRA-LOW-LIGHT, LOW-NOISE UV / VIS CAMERAS SOPHIA 2048B DATASHEET Highlights Breakthrough High-Performance CCD Cameras SOPHIA 2048B cameras are designed
More informationIMAGING GROUP x 1300 imaging array; 20mm x 20mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee
Now Powered by LightField PIXIS: 13 The PIXIS: 13 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras designed expressly for quantitative scientific imaging applications.
More informationIMAGING GROUP x 2048 imaging array; 13.5mm x 13.5mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee
Now Powered by LightField PIXIS: 248 The PIXIS: 248 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras designed expressly for quantitative scientific imaging applications.
More informationIMAGING GROUP. 512 x 512 imaging array; 24 mm x 24 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee
Now Powered by LightField PIXIS: 512 The PIXIS: 512 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras designed expressly for quantitative scientific imaging applications.
More informationPI-MTE3. Datasheet LARGE-FORMAT, IN-VACUUM CAMERAS. Direct detection of soft x-rays. Up to 4k x 4k sensor formats. Reads out as fast as 3 full fps
PI-MTE3 LARGE-FORMAT, IN-VACUUM CAMERAS Datasheet Direct detection of soft x-rays Up to 4k x 4k sensor formats Reads out as fast as 3 full fps PI-MTE3 DATASHEET Highlights Breakthrough In-Vacuum Performance
More informationVideo frame rates and higher to efficiently synchronize with high repetition rate lasers
PI-MAX3:1024 x 256 The PI-MAX3:1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 256 spectroscopy CCD fiber-coupled
More informationConfocal Raman Systems SPECTROSCOPY GROUP
Confocal Raman Systems SPECTROSCOPY GROUP MonoVista CRS Configuration Option PIXIS TE-Cooled CCD Camera Acton Spectrograph Micro-Raman Interface Witness Camera Optional Laser Micro/Macro Transfer Optics
More informationApplications: Astronomy, Photometry, EL/PL Imaging, Luminescence & Fluorescence Imaging, and Bose-Einstein Condensate (BEC) Page 1 of 7 IMAGING GROUP
Now Powered by LightField PIXIS: 124 The PIXIS: 124 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras with 124 x 124 resolution designed for quantitative scientific
More informationFEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy
PI-MAX3:1024i The PI-MAX3:1024i from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1k x 1k interline CCD fiberoptically coupled
More informationProEM -HS:1024BX3 FEATURES BENEFITS
The ProEM-HS: 124BX3 is the most advanced EMCCD camera on the market utilizing the latest low-noise readout electronics and a 124 x 124 EMCCD. This camera delivers single photon sensitivity and the best
More informationPIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels
Powered by LightField PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels The PIXIS-XO series of fully integrated imaging cameras utilizes back illuminated and back illuminated deep depletion CCDs
More informationProEM -HS:1KBX3-10µm
The ProEM-HS:1KBX3-1µm is the fastest EMCCD camera on the market utilizing the latest low-noise readout electronics and a 124 x 124 EMCCD. This camera delivers single photon sensitivity and the best fringe
More informationProEM -HS:1024BX3 FEATURES BENEFITS
ProEM -HS:124BX3 The ProEM-HS: 124BX3 is the most advanced EMCCD camera on the market utilizing the latest low-noise readout electronics and a 124 x 124 EMCCD. This camera delivers single photon sensitivity
More informationBack-illuminated scientific CMOS cameras. Datasheet
Back-illuminated scientific CMOS cameras Datasheet Breakthrough Technology KURO DATASHEET Highlights KURO, from Princeton Instruments, is the world s first backilluminated scientific CMOS (scmos) camera
More informationActon Research SpectruMM TM Complete Spectroscopic- Acquisition Systems
Acton Research SpectruMM TM Complete Spectroscopic- Acquisition Systems A fully integrated spectroscopy lab is as easy as 1, 2, 3... 1. High-Resolution CCD Detectors 2. Industry-Standard Acton Research
More informationCompatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.
PI-MAX 4: 1024f The PI-MAX4:1024f from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1k x 1k full-frame CCD fiberoptically coupled
More informationPyLoN: Applications: Astronomy, Chemiluminescence, Bioluminescence, Phosphor Imaging, Ultra-low light Imaging and Spectroscopy.
Now Powered by LightField PyLoN: 2048 2048 x 2048 The PyLoN: 2048 is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific imaging applications demanding the highest possible
More information20 MHz/16-bit readout 61 fps rate at full-frame resolution. Use ROI/binning for hundreds of frames per second.
ProEM -HS: 512BX3 The ProEM -HS: 512BX3 is the most advanced EMCCD camera on the market. It features Princeton Instruments patented excelon 3 technology which delivers the best combination of sensitivity,
More informationPI-MAX 4: 1024 x 256 SPECTROSCOPY GROUP
Powered by LightField The PI-MAX4: 1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 253 pixel spectroscopy
More informationPI-MAX 4: 1024 x 256
The PI-MAX4: 1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 253 pixel spectroscopy CCD fiber-coupled to
More informationLS-785 High Throughput Lens Spectrograph User Manual
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com LS-785 High Throughput Lens Spectrograph User Manual Ver. 1.2 Table of Contents Chapter 1 -- General...5
More informationPI-MAX 4: 1024 EMB. Applications:
The PI-MAX4: 1024 EMB from Princeton Instruments is the ultimate in ICCD technology. This innovative intensified EMCCD camera (emiccd) features back-illuminated 1024 x 1024 frame transfer EMCCD fiberoptically
More informationSOPHIA -XO 2048B SOPHIA -XO 4096B
SOPHIA -XO 2048B SOPHIA -XO 4096B LARGE-FORMAT, DIRECT-DETECTION CCD CAMERAS FOR SOFT X-RAYS Datasheet SOPHIA-XO DATASHEET Highlights Breakthrough Soft X-ray Performance The SOPHIA-XO 2048B and 4096B represent
More informationPI-MAX 4: 1024i-RF. Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.
The PI-MAX4: 1024i-RF from Princeton Instruments is the ultimate scientific, intensified CCD camera (ICCD) system, featuring a 1k x 1k interline CCD fiberoptically coupled to Gen III filmless intensifiers.
More informationMonoVista CRS+ Raman Microscopes
MonoVista CRS+ Benefits Deep UV to NIR wavelength range Up to 4 integrated multi-line lasers plus port for large external lasers Dual beam path for UV and VIS/NIR Motorized Laser selection Auto Alignment
More informationEasy integration into complex experimental setup
NIRvana: 64ST The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications.
More informationRevolutionary High-Speed Cameras for Spectroscopy
Revolutionary High-Speed Cameras for Spectroscopy Meet BLAZE Features BLAZE & Benefits Specs The Next Generation of Spectroscopy Cameras For close to four decades, Princeton Instruments has produced iconic
More informationFrequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras
Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras Updated: Sep 2010 Includes information on excelon TM Back-illuminated Deep Depletion Cameras 1. What is excelon TM? excelon
More informationQuad-RO: 4320 X-RAY GROUP
Quad-RO: 432 284 x 284 imaging array 24 x 24 µm pixels The Princeton Instruments Quad-RO: 432 is a fully integrated, low noise, 4-port readout camera designed for indirect imaging of x-rays using phosphor
More information195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195.
Hg-Ar spectrum Acquired with Mechelle 5000, 104 x 104 pixel Gen Andor istar and 10 µm slit width Spectroscopy Features and Benefits Compact and robust design with no moving components Ideal for non-lab
More informationNIRvana: 640. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection
NIRvana: 64 The NIRvana: 64 from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications.
More informationSYNCERITY TM 1024 x 256
ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING SYNCERITY TM 1024 x 256 Open-Electrode TE-Cooled CCD
More informationSPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter
SPECTROMETERS USER MANUAL Making spectroscopy brighter 1 Table of contents 1. General Safety Rules... 2 2. Items Supplied... 2 3. Introduction... 3 4. Installation and Operation... 4 4.1. Notes... 7 5.
More informationImaging Spectrometers
JOBIN YVON Imaging Spectrometers ihr Series Uniquely shaped for uniquely superior performance. ihr Series Imaging Spectrometers A Unique Shape for a Unique Spectrometer The difference between ihr spectrometers
More informationNIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection
Powered by LightField The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy
More informationSpectrograph overview:
High performance measurement systems Monochromator Family Gilden Photonics offers a range of integrated optical wavelength solutions in customized designs, OEM design, manufacturing and value added resell
More informationFrequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras
Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras 1. What is excelon? excelon is a new CCD/EMCCD sensor technology jointly developed by Princeton Instruments, e2v and Photometrics.
More informationSeries Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN
Series Spectrometers ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING ihr Series Imaging Spectrometers
More informationSTANDARD SERIES MONOCHROMATOS FEATURES. Highly Customizable Modular Design. Two Configurable Input and Output Ports
STANDARD SERIES MONOCHROMATOS FEATURES Highly Customizable Modular Design Two Configurable Input and Output Ports Configurable turret and Grating Options USB2.0 Communication A Full Line of Input and Output
More informationModular Raman Spectrometers
Modular Raman Flexible Raman from the Raman Experts horiba.com/scientific Flexible and Affordable Raman The new range of modular Raman spectrometers from HORIBA Scientific allows the user to have a flexible
More informationSpecifications. Wavelength range (nm) Focal length (mm) 195. Aperture F/7. Spectral resolution (λ/ λ) 1 (corresponding to 3 pixels FWHM)
Spectroscopy Hg-Ar spectrum Acquired with Mechelle 5000, 1024 x 1024 pixel Gen 2 Andor istar and 10 µm slit width Features and Benefits Compact and robust design with no moving components Ideal for non-lab
More information(Fiber-optic Reosc Echelle Spectrograph of Catania Observatory)
(Fiber-optic Reosc Echelle Spectrograph of Catania Observatory) The echelle spectrograph delivered by REOSC (France), was designed to work at the F/15 cassegrain focus of the 91-cm telescope. The spectrograph
More informationShamrock 303i. Resolution with Newton DU940 CCD nm nm. Aperture F/4
New photograph required Spectroscopy Features and Benefits Pre-aligned, pre-calibrated detector & spectrograph Motorized, individually factory-calibrated systems out-of-the-box operation and seamless integration
More informationLight Sources opmaak.indd :32:50
Light Sources Introduction Illumination light sources are needed for transmission, absorption and reflection spectroscopic setups. For the convenient coupling of the light into our range of fiber optic
More informationWinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent
Datasheet WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, 190 1610* nm * model-dependent With an 11.3 x 11.3 mm active area, 4.2 Mpixels, 5.5 x 5.5 μm pixels, optical and electronic triggering
More informationFLEX 2 NEW. Key points. 3D Confocal Raman, 2 lasers, fiber based, AFM combined
FLEX 2 3D Confocal Raman, 2 lasers, fiber based, AFM combined NEW Key points Compact size 2 lasers, easily switchable 2 confocal operation modes, easily switchable : High Spatial Resolution 35 nm High
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE
TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CMOS TECHNICAL DATA SENSOR RESPONSE DIMENSIONS
More informationHigh resolution Low noise High dynamic range Unparalleled sensitivity. Vision At Its Best
High resolution Low noise High dynamic range Unparalleled sensitivity Vision At Its Best MEGAPLUS MEGAPLUS brand cameras are renowned worldwide for producing unmatched image quality and delivering the
More informationModular Approach and Customized solutions (near field, UV-VIS, etc.)
Compact & Flexible System Configuration High Resolution: < 0.3cm Measurement down to 10cm Confocal Optics for Microscope and Remote Probe Fully Automated 2D, 3D & 4D Raman Imaging Attachable to AFM, XRD,
More informationihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise
ihr Series Research Grade Spectrometers Simply the best imaging spectrometers with no compromise horiba.com/osd Unmatched Flexibility in Applications HORIBA Scientific s Optical Spectroscopy Division
More informationSpecifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Dark Current 2. Pixel Well Depth (typical) e e -
AVAILABLE WITH LOW NOISE & HIGH DYNAMIC RANGE sensor options Apogee Alta Series System Features 1 High Resolution Sensors 1.0 Megapixel sensor with large 24 mm pixels deliver a large field of view with
More informationMonochromator & Imaging Spectrograph
& Imaging Spectrograph Series Selection Guide Features 1. Interface : USB, and RS232C 2. s : 150mm, 200mm, 320mm, 500mm, and 750mm 3. Speed : Fast switching illuminator(galvanometer type) Slow scan (Stepper
More informationWITec Raman Spectroscopy Solutions
Confocal Raman Imaging WITec Raman Spectroscopy Solutions -40-20 0 20 CCD cts 500 1000 1500 2000 2500 3000 3000 relative wavenumbers (cm -1 ) www.witec.de WITec UHTS Ultra-High Throughput Spectrometers
More informationpicoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS
picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS 1 picoemerald Two Colors in One Box Microscopy and Spectroscopy with a Tunable Two-Color Source CARS and SRS microscopy
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
LASERS FOR ANALYTICAL INSTRUMENTATION CW Lasers (Broad and Narrow Spectrum) Nanosecond SLM Lasers Accessories ADVANTAGES One size One control interface One voltage (+5 VDC) One software Many wavelengths
More informationBack Illuminated Scientific CMOS
Prime 95B Scientific CMOS Camera Datasheet CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES Back Illuminated Scientific CMOS Discovery depends on every photon Primary applications: Super-Resolution Microscopy
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
LASERS FOR ANALYTICAL INSTRUMENTATION CW Lasers (Broad and Narrow Spectrum) Nanosecond SLM Lasers Accessories ADVANTAGES One size One control interface One voltage (+5 VDC) One software Many wavelengths
More informationTRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013
TRiCAM Time Resolved intensified CAMera The TRiCAM is a compact Intensified CCD camera for scientific and industrial applications that require 1) lowlight level imaging, 2) ultra-short exposures through
More informationThermo Scientific DXR2 Raman Family
MOLECULAR SPECTROSCOPY Thermo Scientific DXR2 Raman Family Focus on answers, not the technique Product Specifications Easily adapt to any sample challenge using the Thermo Scientific DXR 2 family of Raman
More informationLIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015
LIFA Fluorescence Lifetime Attachment LIFA 151A2 16/3/215 The LIFA is a dedicated system for Fluorescence Lifetime Imaging Microscopy (FLIM). It allows the generation of lifetime images on any widefield
More informationControl & Interface Electronics. CCD Sensor
FEATURES High Performance Scientific Camera Hamamatsu S10141 Sensors 1024 x 122 to 2048 x 506 active pixels 12 µm x 12 µm pixel size Integrated TE Cooling -15 C from 20 C ambient Hermetically sealed Temperature
More informationP recise Eye. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection.
High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection. Long working distance makes lighting and handling easier. Compact size. Coaxial lighting available
More informationhsfc pro 12bit ultra speed intensified imaging
hsfc pro 12bit ultra speed intensified imaging four MCP-image intensifier camera modules ultra fast shutter down to 3ns (optional 1.5ns) in single mode excellent sensitivity of the system allows single
More informationRaman Sample Holders
Raman Sample Holders Ocean Optics offers several sample holders for Raman analysis of liquids and solids, including a multipurpose holder that can be configured for fluorescence and other measurements.
More informationVersatile laser Raman Spectrometer. RMP-500 series
Versatile laser Raman Spectrometer RMP-500 series About RMP-500 RMP-500 series is a compact and versatile laser Raman spectrometer consisting of a micro Raman probe connected through fiber optics to the
More informationPrizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications
Mic-LED-635 High Power Collimated Red LED Light Source for Fluorescence Microscopy Featuring Prizmatix Modular Design for Multi-Wavelength and Fiberoptic Setup Ver. 01 Introduction The compact Mic-LED-635,
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
CW Lasers Combiners Q-switch Lasers >20 s MM/SM/PM fiber Single-frequency options 405 nm to 660 nm 4 wavelengths Open beam or Fiber 1029 nm / 514.5 nm High pulse energy Single Longitudinal Mode LASERS
More informationTechnical Specifications for High speed PIV and High speed PIV-PLIF system
Technical Specifications for High speed PIV and High speed PIV-PLIF system MODULE A. HIGH SPEED PIV (3-C) A1. Double Cavity High Speed Laser (up to 10 khz): The vendor should provide Dual Head (DH) laser
More informationHigh-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology
2015 Princeton Instruments, Inc. All rights reserved. High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology The PI-MAX4:1024EMB emiccd camera seamlessly
More informationBeam Analysis Camera Based Beam Propagation Analyzer: M Automatic M 2 - at Production Speeds. Manual M 2
3.7.1 Camera Based Beam Propagation Analyzer: M 2 ISO compliant Automatically measure your beam quality in under 1 minutes Tune your laser for best operation Specifically developed for continuous usage
More informationApplication Wavelength Range Type Principle Product. Color / VIS / NIR nm Tungsten Halogen Continuous AvaLight-HAL(-S)
Introduction Illumination light sources are needed for transmission, absorption and reflection spectroscopic setups. For the convenient coupling of the light into our range of fiber optic cables, bundles
More informationApex High Performance Spectrometer
Apex High Performance Spectrometer 1 Elite High Performance Spectrometers Challenge Integrated, high end instruments are required to detect low light levels for challenging Fluorescence and Raman applications
More informationHigh Resolution BSI Scientific CMOS
CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES High Resolution BSI Scientific CMOS Prime BSI delivers the perfect balance between high resolution imaging and sensitivity with an optimized pixel design and
More informationOverview. Etalon-Based FSRS Setup APPLICATION NOTE
2016 Princeton Instruments, Inc. All rights reserved. Advanced CCD Cameras and Imaging Spectrographs Facilitate Acquisition of Novel Femtosecond Stimulated Raman Spectroscopy Data To Improve SERS Biosensors
More informationidus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88
Spectroscopy Features and Benefits Peak QE of 95% High detector sensitivity TE cooling to 100 C Negligible dark current without the inconvenience of LN 2 UltraVac 1 Permanent vacuum integrity, critical
More informationAttachable to other Advanced analytical tools (e.g AFM, XRD, SEM etc.) Detect and measure deposits in liquid as it is (Particle ID Detection)
Compact & Flexible System Configuration High Resolution: < 0.3cm Measurement down to 10cm Confocal Optics for Microscope and Remote Probe Fully Automated 2D, 3D & 4D Raman Imaging Attachable to other Advanced
More informationOTO Photonics. Sidewinder TM Series Datasheet. Description
OTO Photonics Sidewinder TM Series Datasheet Description SW (Sidewinder TM ) Series spectrometer,built with the InGaAs type sensor and high performance 32bits RISC controller in, is specially designed
More information25.6 mm wide / 1600 pixel, 3 MHz Spectroscopy EMCCD. Specifications Summary 1. Output node well depth: Conventional mode Electron Multiplying mode
Features and Benefits EM sensor technology
More informationSpecifications Summary 1. Array Size (pixels) Pixel Well Depth (typical) 94,000 e - Dark Current 2. Read Noise 3
Apogee Alta Series System Features 1 High Resolution Sensor 9.3 Megapixel sensor with 12 mm pixels delivers an exceptionally large field of view with high resolution. Programmable TE cooling down to 45
More informationIntroduction to Diffraction Gratings
Introduction to Diffraction Diffraction (Ruled and Holographic) Diffraction gratings can be divided into two basic categories: holographic and ruled. A ruled grating is produced by physically forming grooves
More information800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)
Quantum efficiency (%) 100 90 80 70 60 50 40 30 Spectroscopy 20 10 0 1 1.2 1.4 1.6 1.8 2 2.2 2.4 Wavelength (µm) Features and Benefits 0.8 to 2.2 μm Operating wavelength range Peak QE of > 70% High detector
More informationWAVELENGTH MANAGEMENT
Camera Accessories WAVELENGTH MANAGEMENT UV CONVERTERS UV Converters take advantage of a phenomenon called fluorescence to extend the performance range of the Beamage beam profiling camera to ultraviolet
More information. Ideal for fast, shutterless imaging
IMAGING DV860 Andor s ixon DV860 EMCCD camera has single photon detection capability without an image intensifier, combined with greater than 90% QE of a sensor. Containing a 128x128 L3Vision TM Frame
More informationFIXED FOCAL LENGTH LENSES
Edmund Optics BROCHURE FIXED FOCAL LENGTH LENSES INNOVATION STARTS HERE... Global Design & Support Rapid Prototyping Volume Manufacturing & Pricing Contact us for a Stock or Custom Quote Today! USA: +1-856-547-3488
More informationWAVELENGTH MANAGEMENT
BEAM DIAGNOS TICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS Camera Accessories WAVELENGTH MANAGEMENT UV CONVERTERS UV Converters
More informationAPPLICATIONS KEY FEATURES. High-speed intensified Camera Attachment
HiCATT High-speed intensified Camera Attachment The HiCATT is an intensified camera attachment specifically designed for use in combination with high-speed cameras. It can be used to amplify low light
More informationscmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary
Ultra Sensitive Imaging Low Light Imaging Features and Benefits Compact and light Ideal for integration into space restrictive set-ups 1.2 e - read noise Lower detection limit than any CCD 5.5 megapixel
More informationLIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014
LIFA Fluorescence Lifetime Attachment The LIFA is a dedicated system for Fluorescence Lifetime Imaging Microscopy (FLIM). It allows the generation of lifetime images on any widefield fluorescence microscope
More informationTuCam. Features and Benefits. Andor TuCam - High Performance, Two Camera Imaging Adapter. Specifications Summary. Applications Guide
Ultra Sensitive Imaging Microscopy Systems Features and Benefits Largest aperture Unique 22 mm aperture for large format sensors e.g. Neo and Zyla scmos High quality achromatic lenses Image from 425 -
More informationPI-MAX4 Camera System
PI-MAX4 Camera System 4411-0139 Issue 9 July 3, 2018 Revision History (Sheet 1 of 2) Issue Date List of Changes Issue 9 July 3, 2018 Issue 9 of this document incorporates the following changes: Added Windows
More informationLED Evenement 2014 Spectroscopy - Straylight. Avantes BV Apeldoorn, The Netherlands
LED Evenement 2014 Spectroscopy - Straylight Avantes BV Apeldoorn, The Netherlands Content: - Company - Spectroscopy - Spectrometer measuring light - Straylight - How to prevent - Why - conclusion Introduction
More informationEMBED2000+ Data Sheet
EMBED2000+ Data Sheet Description The Ocean Optics EMBED2000+ Spectrometer includes the linear CCD-array optical bench, plus all the circuits necessary to operate the array and convert to a digital signal.
More informationSpectro-115E TM and Spectro-115U TM Spectroelectrochemical System. Operator s Manual
Spectro-115E TM and Spectro-115U TM Spectroelectrochemical System Operator s Manual Limited Warranty Gamry Instruments, Inc. warrants to the original user of this product that it shall be free of defects
More informationillumia plus Light Measurement Systems
illumia plus Light Measurement Systems Flexible, modular solutions with centralized data management FLEXIBILITY Introducing Labsphere illumia plus light measurement systems flexibility to meet your most
More informationandor.com Scientific CMOS - Fast, sensitive, compact and light Features and Benefits Specifications Summary Ultra Sensitive Imaging Low Light Imaging
Interline CCD 5.5 e - read noise Andor scmos 1.2 e - read noise Low Light Imaging Ultra Sensitive Imaging Upgrading to Zyla scmos can radically improve the performance of your fluorescence microscope Features
More information600 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)
Quantum efficiency (%) 100 90 80 70 60 50 40 30 Spectroscopy 20 10 0 0.6 0.8 1 1.2 1.4 1.6 1.8 Wavelength (µm) Features and Benefits 0.6 to 1.7 μm Operating wavelength range Peak QE of > 85% High detector