Spectrograph overview:

Size: px
Start display at page:

Download "Spectrograph overview:"

Transcription

1 High performance measurement systems Monochromator Family Gilden Photonics offers a range of integrated optical wavelength solutions in customized designs, OEM design, manufacturing and value added resell of optical spectroscopy products. ZOLIX is one of Gilden Photonics important partners and it has the professional R & D and manufacturer of spectroscopy instruments. Spectroscopy instruments series products include, Monochromators and components including the light source such as Tungsten-Halogen Light Source, Xenon Light Source, SiC infrared light source; the detectors such as DPbs Series Detectors, InGaAs Series Detectors, Photomultiplier and Silicon Series Detectors; Data Collection Systems. Main features: modular product, Spectrograph overview: As the new generation of, Omni-λinherit the SBP series multi-grating turret design features. DSP chip has been used in the control circuit, which makes it simply to control the equipment. That will play the equipment covered by UV-VIS-IR spectral range advantage, and that will become more flexible to choose spectral range and resolution according to the need. USB2.0 replaced the traditional RS-232, which not only makes it simply to connect the spectrographs, but also greatly improves communication rate of spectrographs. Due to the new DSP chip design, it is more flexible for the choosing of the multi-import and multi-export. The spectrographs can automatically choose doubleentry, double-export. With the light source, detector (single-point detectors and arrays CCD, etc.), the spectrographs can building up series spectroscopy systems, such as fluorescence, Raman, transmission / reflection, absorption spectra and emission spectra system. SSM series (sine structure) can ensure the wavelength accuracy and repeatability after working long hours by improving the traditional sine guide screw drive structure and using high-precision grinding thread. SGM series are new small grating spectrographs with new design. SGM series are suited to professional applications of Spectral measurements, and OEM customer. Omni-λ series mechanical views Omni-λ series grating spectrographs name rule format

2 150mm 300mm 500mm 750mm focus are suited to different spectral range. Classic Czerny-Turner design Multi-grating turret, which plays the equipment covered by UV-VIS-IR spectral range advantage, and that will become more flexible to choose spectral range and resolution according to the need. With the 68 68mm grating effectively improve the efficiency in the use of the light source. Optimize the design for the infrared wave band( >1μm) using gold-plated optical mirror to improve the efficiency of reflection. USB2.0 replaced the traditional RS-232, which not only makes it simply to connect the spectrographs, but also greatly improves communication rate of spectrographs. Due to the new DSP chip design, it is more flexible for the choosing of the multi-import and multi-export. The spectrographs can automatically choose double-entry, double-export. More accurate positioning. With the light source, detector (single-point detectors and arrays CCD, etc.), the spectrographs can building up series spectroscopy systems, such as fluorescence, Raman, transmission / reflection, absorption spectra and emission spectra system. Optional automatic filter wheel Automatic slit option Shutter option OMNI - λ SEIRES SPECIFICATION (@ 1200 G/ MM GRATING) PARAMETER OMNI-λ150 OMNI-λ300 OMNI-λ500 OMNI-λ750 UNIT Focal Length mm Relative Aperture f / 4.2 f / 3.9 f / 6.5 f / 9,7 Optical Configuration C - T nm Mechanical Scanning Range nm Resolution nm Reciprocal Dispersion nm / mm Wavelength Accuracy ± 0.25 ± 0.2 nm Wavelength Repeatability ± 0.1 ± 0.1 nm Step Size nm Focal Plane Area 25 (W) 10 (H) 25 (W) 14 (H) mm Optical Axis Height 134 mm Slit Width: mm (can be adjusted continually), optional motorized slit. Height: optional 2, 4, 10, 14 mm Grating Size mm Grating Turret Dual triple Outline mm Weight kg Interface USB 2.0, optional RS - 232

3 Slit configuration Manually slit (standard) Motorized slit (option) Graded adjustable slit (option) OMNI-λ SERIES RECIPROCAL DISPERSION AND SPECTRAL BANDWIDTH LINE DENSITY (G/MM) RECIPROCAL DISPERSION NM) SPECTRAL BANDWIDTH ( 100 μm SLIT) OMNIλ150 OMNIλ300 OMNIλ500 OMNIλ750 OMNIλ150 OMNIλ300 OMNIλ500 OMNIλ

4 Standard Grating Selections

5 OMNI-λ SERIES GRATINGS PART LINE DESITY ( G/MM) BLAZE WAVELENGTH (NM) SIZE (MM MM) WAVELENGTH REGION (NM) OMNI-λ 150 SERIES GRATINGS H 1800 Holographic UV D D 50 3 μm & 10 μm OMNI-λ 300 / 500 / 750 SERIES GRATINGS H 2400 Holographic UV V 2400 ho Holographic H 1800 Holographic UV D μm & 10 μm

6 OMNI-λ SERIES PRODUCT SELECTION TABLE MODEL DESCRIPTION OMNI-λ 150 SERIES Omni-λ mm focus monochromator, side entrance, slit side exit, supports 2 gratings Omni-λ mm focus IR monochromator, side entrance, slit side exit, supports 2 gratings OMNI-λ 300 SERIES Omni-λ mm focus monochromator, side entrance, slit front exit, supports 3 gratings Omni-λ3006 Omni-λ mm focus monochromator, side entrance, CCD front exit, supports 3 gratings 300 mm focus monochromator, side entrance, dual front exit, supports 3 gratings Omni-λ3008 Omni-λ3009 Omni-λ mm focus spectrograph, side entrance, slit side exit and CCD front exit, supports 3 gratings 300 mm focus monochromator, side entrance, slit front exit, supports 3 gratings 300 mm focus IR monochromator, side entrance, slit front exit, supports 3 gratings Omni-λ mm focus IR monochromator, side entrance, dual slit-exit, supports 3 gratings Omni-λ mm focus IR monochromator, side entrance, slit side exit, supports 3 gratings

7 OMNI-λ SERIES PRODUCT SELECTION TABLE MODEL DESCRIPTION OMNI-λ 500 SERIES Omni-λ5005 Omni-λ5006 Omni-λ mm focus monochromator, side entrance, slit front exit, supports 3 gratings 500 mm focus spectrograph, side entrance, CCD front exit, supports 3 gratings 500 mm focus monochromator, side entrance, dual slit-exit, supports 3 gratings Omni-λ5008 Omni-λ5009 Omni-λ5015 Omni-λ5017 Omni-λ mm focus spectrograph, side entrance, slit side exit and CCD front exit, supports 3 gratings 500 mm focus monochromator, side entrance, slit side exit, supports 3 gratings 500 mm focus IR monochromator, side entrance, slit front exit, supports 3 gratings 500 mm focus IR monochromator, side entrance, slit side exit, supports 3 gratings 500 mm focus IR monochromator, side entrance, slit front exit, supports 3 gratings Omni-λ5025 Omni-λ5026 Omni-λ5027 Omni-λ mm focus monochromator, dual entrances, slit front exit, supports 3 gratings 500 mm focus monochromator, dual entrances, CCD front exit, supports 3 gratings 500 mm focus monochromator, dual entrances, dual slit-exit, supports 3 gratings 500 mm focus spectrograph, dual entrances, slit side exit and CCD front exit, supports 3 gratings OMNI-λ 750 SERIES Omni-λ7505 Omni-λ7506 Omni-λ7507 Omni-λ7508 Omni-λ7509 Omni-λ7515 Omni-λ7517 Omni-λ mm focus monochromator, side entrance, slit front exit, supports 3 gratings 750 mm focus monochromator, side entrance, CCD front exit, supports 3 gratings 750 mm focus monochromator, side entrance, dual slit-exit, supports 3 gratings 750 mm focus spectrograph, side entrance, slit side exit and CCD front exit, supports 3 gratings 750 mm focus monochromator, side entrance, slit side exit, supports 3 gratings 750 mm focus IR monochromator, side entrance, slit front exit, supports 3 gratings 750 mm focus IR monochromator, side entrance, dual slit-exit, supports 3 gratings 750 mm focus IR monochromator, side entrance, slit side exit, supports 3 gratings Omni-λ7525 Omni-λ7526 Omni-λ7527 Omni-λ mm focus monochromator, dual entrances, slit front exit, supports 3 gratings 750 mm focus spectrograph, dual entrances, CCD front exit, supports 3 gratings 750 mm focus monochromator, dual entrances, dual slit-exit, supports 3 gratings 750 mm focus spectrograph, dual entrances, slit side exit and CCD front exit, supports 3 gratings

Monochromator. Grating STANDARD GRATING SELECTIONS (0)

Monochromator. Grating STANDARD GRATING SELECTIONS (0) Monochromator STANDARD GRATING SELECTIONS WWW.GILDENPHOTONICS.COM SALES@GILDENPHOTONICS.COM +44 (0) 141 952 9475 Gilden Photonics had taken a leading position in the design, development and manufacture

More information

Imaging Spectrometers

Imaging Spectrometers JOBIN YVON Imaging Spectrometers ihr Series Uniquely shaped for uniquely superior performance. ihr Series Imaging Spectrometers A Unique Shape for a Unique Spectrometer The difference between ihr spectrometers

More information

STANDARD SERIES MONOCHROMATOS FEATURES. Highly Customizable Modular Design. Two Configurable Input and Output Ports

STANDARD SERIES MONOCHROMATOS FEATURES. Highly Customizable Modular Design. Two Configurable Input and Output Ports STANDARD SERIES MONOCHROMATOS FEATURES Highly Customizable Modular Design Two Configurable Input and Output Ports Configurable turret and Grating Options USB2.0 Communication A Full Line of Input and Output

More information

Series Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Series Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN Series Spectrometers ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING ihr Series Imaging Spectrometers

More information

ihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise

ihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise ihr Series Research Grade Spectrometers Simply the best imaging spectrometers with no compromise horiba.com/osd Unmatched Flexibility in Applications HORIBA Scientific s Optical Spectroscopy Division

More information

Monochromator & Imaging Spectrograph

Monochromator & Imaging Spectrograph & Imaging Spectrograph Series Selection Guide Features 1. Interface : USB, and RS232C 2. s : 150mm, 200mm, 320mm, 500mm, and 750mm 3. Speed : Fast switching illuminator(galvanometer type) Slow scan (Stepper

More information

MonoVista CRS+ Raman Microscopes

MonoVista CRS+ Raman Microscopes MonoVista CRS+ Benefits Deep UV to NIR wavelength range Up to 4 integrated multi-line lasers plus port for large external lasers Dual beam path for UV and VIS/NIR Motorized Laser selection Auto Alignment

More information

Confocal Raman Systems SPECTROSCOPY GROUP

Confocal Raman Systems SPECTROSCOPY GROUP Confocal Raman Systems SPECTROSCOPY GROUP MonoVista CRS Configuration Option PIXIS TE-Cooled CCD Camera Acton Spectrograph Micro-Raman Interface Witness Camera Optional Laser Micro/Macro Transfer Optics

More information

Acton Research SpectruMM TM Complete Spectroscopic- Acquisition Systems

Acton Research SpectruMM TM Complete Spectroscopic- Acquisition Systems Acton Research SpectruMM TM Complete Spectroscopic- Acquisition Systems A fully integrated spectroscopy lab is as easy as 1, 2, 3... 1. High-Resolution CCD Detectors 2. Industry-Standard Acton Research

More information

195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195.

195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195. Hg-Ar spectrum Acquired with Mechelle 5000, 104 x 104 pixel Gen Andor istar and 10 µm slit width Spectroscopy Features and Benefits Compact and robust design with no moving components Ideal for non-lab

More information

Spectrometers: Monochromators / Slits

Spectrometers: Monochromators / Slits Spectrometers: Monochromators / Slits Monochromator Characteristics Dispersion: The separation, or wavelength selectivity, of a monochromator is dependent on its dispersion. Angular Dispersion: The change

More information

Shamrock 303i. Resolution with Newton DU940 CCD nm nm. Aperture F/4

Shamrock 303i. Resolution with Newton DU940 CCD nm nm. Aperture F/4 New photograph required Spectroscopy Features and Benefits Pre-aligned, pre-calibrated detector & spectrograph Motorized, individually factory-calibrated systems out-of-the-box operation and seamless integration

More information

Throughput of an Optical Instrument II: Physical measurements, Source, Optics. Q4- Number of 500 nm photons per second generated at source

Throughput of an Optical Instrument II: Physical measurements, Source, Optics. Q4- Number of 500 nm photons per second generated at source Throughput of an Optical Instrument II: Physical measurements, Source, Optics Question- Value Q1- Percent output between 450-550 nm by mass Answer (w/ units) Q2- Energy in J of a 500 nm photon Q3- Flux

More information

FHR. Fully Automated. Imaging Spectrometer. User Manual

FHR. Fully Automated. Imaging Spectrometer. User Manual FHR Fully Automated Imaging Spectrometer User Manual Part Number 31505764 - Revision 1 Copyright April, 11 HORIBA Jobin Yvon Inc., Optical Spectroscopy Division. All rights reserved. Portions of the software

More information

Operating Instructions Acton Research Corporation SpectraPro-750i

Operating Instructions Acton Research Corporation SpectraPro-750i 530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation SpectraPro-750i 0.750 Meter Focal Length Triple

More information

Chemistry Instrumental Analysis Lecture 6. Chem 4631

Chemistry Instrumental Analysis Lecture 6. Chem 4631 Chemistry 4631 Instrumental Analysis Lecture 6 UV to IR Components of Optical Basic components of spectroscopic instruments: stable source of radiant energy transparent container to hold sample device

More information

Renishaw invia Raman Microscope (April 2006)

Renishaw invia Raman Microscope (April 2006) Renishaw invia Raman Microscope (April 2006) I. Starting the System 1. The main system unit is ON all the time. 2. Switch on the Leica microscope and light source for reflective bright field (BF) imaging.

More information

Specifications. Wavelength range (nm) Focal length (mm) 195. Aperture F/7. Spectral resolution (λ/ λ) 1 (corresponding to 3 pixels FWHM)

Specifications. Wavelength range (nm) Focal length (mm) 195. Aperture F/7. Spectral resolution (λ/ λ) 1 (corresponding to 3 pixels FWHM) Spectroscopy Hg-Ar spectrum Acquired with Mechelle 5000, 1024 x 1024 pixel Gen 2 Andor istar and 10 µm slit width Features and Benefits Compact and robust design with no moving components Ideal for non-lab

More information

Control of Light. Emmett Ientilucci Digital Imaging and Remote Sensing Laboratory Chester F. Carlson Center for Imaging Science 8 May 2007

Control of Light. Emmett Ientilucci Digital Imaging and Remote Sensing Laboratory Chester F. Carlson Center for Imaging Science 8 May 2007 Control of Light Emmett Ientilucci Digital Imaging and Remote Sensing Laboratory Chester F. Carlson Center for Imaging Science 8 May 007 Spectro-radiometry Spectral Considerations Chromatic dispersion

More information

SPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter

SPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter SPECTROMETERS USER MANUAL Making spectroscopy brighter 1 Table of contents 1. General Safety Rules... 2 2. Items Supplied... 2 3. Introduction... 3 4. Installation and Operation... 4 4.1. Notes... 7 5.

More information

LS-785 High Throughput Lens Spectrograph User Manual

LS-785 High Throughput Lens Spectrograph User Manual 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com LS-785 High Throughput Lens Spectrograph User Manual Ver. 1.2 Table of Contents Chapter 1 -- General...5

More information

Optics Vac Work MT 2008

Optics Vac Work MT 2008 Optics Vac Work MT 2008 1. Explain what is meant by the Fraunhofer condition for diffraction. [4] An aperture lies in the plane z = 0 and has amplitude transmission function T(y) independent of x. It is

More information

Introduction to. 3D Scanning Confocal Microscope with Spectrometer

Introduction to. 3D Scanning Confocal Microscope with Spectrometer Introduction to Nanofinder-S 3D Scanning Confocal Microscope with Spectrometer Alexei Kuzmin E-mail: a.kuzmin@cfi.lu.lv Principle of Confocal Microscopy Laser X-Y Excitation Pinhole Excitation Filter Objective

More information

Apex High Performance Spectrometer

Apex High Performance Spectrometer Apex High Performance Spectrometer 1 Elite High Performance Spectrometers Challenge Integrated, high end instruments are required to detect low light levels for challenging Fluorescence and Raman applications

More information

Astronomical spectrographs. ASTR320 Wednesday February 20, 2019

Astronomical spectrographs. ASTR320 Wednesday February 20, 2019 Astronomical spectrographs ASTR320 Wednesday February 20, 2019 Spectrographs A spectrograph is an instrument used to form a spectrum of an object Much higher spectral resolutions than possible with multiband

More information

1.1 The HeNe and Fourier Lab CCD Camera

1.1 The HeNe and Fourier Lab CCD Camera Chapter 1 CCD Camera Operation 1.1 The HeNe and Fourier Lab CCD Camera For several experiments in this course you will use the CCD cameras to capture images or movies. Make sure to copy all files to your

More information

Lenses lens equation (for a thin lens) = (η η ) f r 1 r 2

Lenses lens equation (for a thin lens) = (η η ) f r 1 r 2 Lenses lens equation (for a thin lens) 1 1 1 ---- = (η η ) ------ - ------ f r 1 r 2 Where object o f = focal length η = refractive index of lens material η = refractive index of adjacent material r 1

More information

Acton Research Corporation Model VM Meter Triple Grating Vacuum Monochromator Operating Instructions

Acton Research Corporation Model VM Meter Triple Grating Vacuum Monochromator Operating Instructions Instrument Division Fax: 978-263-5086 Instrument Division Phone: 978-263-3584 Address: 530 Main Street, Acton, MA 01720 USA Web Site: www.acton-research.com Acton Research Corporation Model VM-504 0.39

More information

2. THE PHYSICS OF DIFFRACTION GRATINGS

2. THE PHYSICS OF DIFFRACTION GRATINGS Diffraction Grating Handbook - Chapter 1 2. THE PHYSICS OF DIFFRACTION GRATINGS PREVIOUS CHAPTER NEXT CHAPTER Copyright 2002, Thermo RGL, All Rights Reserved TABLE OF CONTENTS 2.1. THE GRATING EQUATION

More information

Spectrographs. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution.

Spectrographs. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution. Spectrographs C A Griffith, Class Notes, PTYS 521, 2016 Not for distribution 1 Spectrographs and their characteristics A spectrograph is an instrument that disperses light into a frequency spectrum, which

More information

UV-VIS Spectrophotometer

UV-VIS Spectrophotometer UV-VIS Spectrophotometer LOW STRAY LIGHT EXCELLENT STABILITY EASILY UPDATED MANY APPLICATIONS LOW COST HIGH QUALITY SMALL FOOTPRINT USER FRIENDLY SOFTWARE UV-VIS Spectrophotometer 1/2 PG INSTRUMENTS LIMITED

More information

LED Evenement 2014 Spectroscopy - Straylight. Avantes BV Apeldoorn, The Netherlands

LED Evenement 2014 Spectroscopy - Straylight. Avantes BV Apeldoorn, The Netherlands LED Evenement 2014 Spectroscopy - Straylight Avantes BV Apeldoorn, The Netherlands Content: - Company - Spectroscopy - Spectrometer measuring light - Straylight - How to prevent - Why - conclusion Introduction

More information

(Fiber-optic Reosc Echelle Spectrograph of Catania Observatory)

(Fiber-optic Reosc Echelle Spectrograph of Catania Observatory) (Fiber-optic Reosc Echelle Spectrograph of Catania Observatory) The echelle spectrograph delivered by REOSC (France), was designed to work at the F/15 cassegrain focus of the 91-cm telescope. The spectrograph

More information

NIRSpec Technical Note NTN / ESA-JWST-TN Author(s): G. Giardino Date of Issue: November 11, 2013 Version: 1.0

NIRSpec Technical Note NTN / ESA-JWST-TN Author(s): G. Giardino Date of Issue: November 11, 2013 Version: 1.0 NIRSpec Technical Note NTN-013-011/ ESA-JWST-TN-093 Author(s): G. Giardino Date of Issue: November 11, 013 Version: 1.0 estec European Space Research and Technology Centre Keplerlaan 1 01 AZ Noordwijk

More information

Operating Instructions OEM Spectrometer RU 60

Operating Instructions OEM Spectrometer RU 60 OEM Spectrometer RU 60 JETI Technische Instrumente GmbH Tatzendpromenade 2 D-07745 Jena Tel. +49-3641-225 680 Fax. +49-3641-225 681 E-mail: sales@jeti.com Internet: www.jeti.com Table of contents 1. Features

More information

COMPACT 1/8 METER COMPUTER

COMPACT 1/8 METER COMPUTER COMPACT 1/8 METER COMPUTER CONTROLLED MONOCHROMATOR / SPECTROGRAPH Single piece base construction, direct grating drive, and anti-backlash gearing ensure this unit is rugged and stable enough for demanding

More information

WITec Raman Spectroscopy Solutions

WITec Raman Spectroscopy Solutions Confocal Raman Imaging WITec Raman Spectroscopy Solutions -40-20 0 20 CCD cts 500 1000 1500 2000 2500 3000 3000 relative wavenumbers (cm -1 ) www.witec.de WITec UHTS Ultra-High Throughput Spectrometers

More information

Modular Approach and Customized solutions (near field, UV-VIS, etc.)

Modular Approach and Customized solutions (near field, UV-VIS, etc.) Compact & Flexible System Configuration High Resolution: < 0.3cm Measurement down to 10cm Confocal Optics for Microscope and Remote Probe Fully Automated 2D, 3D & 4D Raman Imaging Attachable to AFM, XRD,

More information

UV-VIS Spectrophotometer

UV-VIS Spectrophotometer T60 UV-VIS Spectrophotometer LOW STRAY LIGHT EXCELLENT STABILITY EASILY UPDATED MANY APPLICATIONS LOW COST HIGH QUALITY SMALL FOOTPRINT USER FRIENDLY SOFTWARE T60 UV-VIS Spectrophotometer 1/2 PG INSTRUMENTS

More information

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com Lever Your Genius Spectrograph & Accessories Datasheet FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has its own specially designed ecosystem

More information

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com Lever Your Genius Spectrograph & Accessories Datasheet FERGIE DATASHEET Highlights 2 FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has

More information

Versatile laser Raman Spectrometer. RMP-500 series

Versatile laser Raman Spectrometer. RMP-500 series Versatile laser Raman Spectrometer RMP-500 series About RMP-500 RMP-500 series is a compact and versatile laser Raman spectrometer consisting of a micro Raman probe connected through fiber optics to the

More information

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI I. Background theory. 1. Characteristics of the apparatus: prismatic, grating, interferometers. 2. Operating

More information

Standard Operating Procedure for the Horiba FluroMax-4

Standard Operating Procedure for the Horiba FluroMax-4 Standard Operating Procedure for the Horiba FluroMax-4 Adapted from Horiba Operations Manual Created by Michael Delcau, Modified by Brian Lamp The Fluoromax is capable of making a variety of measurements.

More information

Optical properties and characterization

Optical properties and characterization Optical properties and characterization Name Picture Description Site Responsible 1 Laser Nd:YAG MAPLE (Matrix Assisted Pulsed Laser Evaporation) system for biomaterials and polymeric thin film deposition

More information

WAVELENGTH MANAGEMENT

WAVELENGTH MANAGEMENT Camera Accessories WAVELENGTH MANAGEMENT UV CONVERTERS UV Converters take advantage of a phenomenon called fluorescence to extend the performance range of the Beamage beam profiling camera to ultraviolet

More information

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available. Now Powered by LightField PyLoN:100 1340 x 100 The PyLoN :100 is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible

More information

AVANTES EVO SERIES. Timing and Triggering

AVANTES EVO SERIES. Timing and Triggering AVANTES EVO SERIES Avantes is proud to announce the latest additions to our EVO series spectrometers in UV/VIS and NIR range: EVO series; why? With the introduction of the AS7010 electronics board, Avantes

More information

Physical & Electromagnetic Optics: Diffraction Gratings

Physical & Electromagnetic Optics: Diffraction Gratings 31/05/2018 Physical & Electromagnetic Optics: Diffraction Gratings Optical Engineering Prof. Elias N. Glytsis School of Electrical & Computer Engineering National Technical University of Athens Multiple

More information

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CMOS TECHNICAL DATA SENSOR RESPONSE DIMENSIONS

More information

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD 20723 (301) 953-6871 (301) 953-6670 fax Understand the instrument. Be able to convert measured counts/pixel on-orbit into

More information

Understanding and selecting diffraction gratings

Understanding and selecting diffraction gratings Understanding and selecting diffraction gratings Diffraction gratings are used in a variety of applications where light needs to be spectrally split, including engineering, communications, chemistry, physics

More information

Operating Instructions Acton SP-150

Operating Instructions Acton SP-150 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com Operating Instructions Acton SP-150 0.150 Meter Focal Length Dual Grating Imaging Monochromator / Spectrograph

More information

DMS 803 FEATURES OPTIONS GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION

DMS 803 FEATURES OPTIONS GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION Turnkey solution with motorized scanning for detailed electro-optical display characterization for quality control, research and development. FEATURES

More information

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com Lever Your Genius Spectrograph & Accessories Datasheet FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has its own specially designed ecosystem

More information

Overview. Etalon-Based FSRS Setup APPLICATION NOTE

Overview. Etalon-Based FSRS Setup APPLICATION NOTE 2016 Princeton Instruments, Inc. All rights reserved. Advanced CCD Cameras and Imaging Spectrographs Facilitate Acquisition of Novel Femtosecond Stimulated Raman Spectroscopy Data To Improve SERS Biosensors

More information

Attachable to other Advanced analytical tools (e.g AFM, XRD, SEM etc.) Detect and measure deposits in liquid as it is (Particle ID Detection)

Attachable to other Advanced analytical tools (e.g AFM, XRD, SEM etc.) Detect and measure deposits in liquid as it is (Particle ID Detection) Compact & Flexible System Configuration High Resolution: < 0.3cm Measurement down to 10cm Confocal Optics for Microscope and Remote Probe Fully Automated 2D, 3D & 4D Raman Imaging Attachable to other Advanced

More information

TRIAX Series Spectrometers

TRIAX Series Spectrometers Getting Started TRIAX Series Spectrometers TRIAX 180/190 TRIAX 320 TRIAX 550 Part Number 81034 Issued February 1999 This manual is intended to provide the first-time user with basic information and simple

More information

powered by TAS Technology

powered by TAS Technology Highest Performance - Unmatched Accuracy and Reliability Built Tough for Plant Floor and Lab Environments Fast - Results in 30 Seconds or Less for Immediate Feedback Easy to Implement, Operate and Maintain

More information

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection Powered by LightField The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy

More information

Operating Instructions for Model Remote Scan Controller for SpectraPro Monochromators SP-300i/SP-500i

Operating Instructions for Model Remote Scan Controller for SpectraPro Monochromators SP-300i/SP-500i 530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions for Model 300-749 Remote Scan Controller for SpectraPro Monochromators

More information

PART IX. INSTRUMENTATION FOR THE SPECTRAL DISPERSION AND ISOLATION OF OPTICAL RADIATION (IUPAC

PART IX. INSTRUMENTATION FOR THE SPECTRAL DISPERSION AND ISOLATION OF OPTICAL RADIATION (IUPAC PART IX. INSTRUMENTATION FOR THE SPECTRAL DISPERSION AND ISOLATION OF OPTICAL RADIATION (IUPAC Recommendations 1995) (Originally prepared for publication by L.R.P. Butler and K. Laqua) 1 INTRODUCTION This

More information

Spectroscopic equipment. Multispectral Imaging

Spectroscopic equipment. Multispectral Imaging Spectroscopic equipment Multispectral Imaging Basic spectroscopic arrangement Source Sample Analyzer Detector Sun Lamps Lasers LEDs Synchrotron Plants Forests Tissue Cells Flames Chemical compounds etc.

More information

X-Ray fluorescence and Raman spectroscopy

X-Ray fluorescence and Raman spectroscopy X-Ray fluorescence and Raman spectroscopy Advanced physics laboratory (nd part) 4CFU Catalini Letizia, De Angelis Giulia Vittoria, Piselli Verdiana Abstract In this paper we report about two different

More information

Waves Spectrometer Software

Waves Spectrometer Software Waves Spectrometer Software User Guide October 12, 2018 , the pulse logo, Connecting everything, Avago Technologies, Avago, and the A logo are among the trademarks of and/or its affiliates in the United

More information

WAVELENGTH MANAGEMENT

WAVELENGTH MANAGEMENT BEAM DIAGNOS TICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS Camera Accessories WAVELENGTH MANAGEMENT UV CONVERTERS UV Converters

More information

Easy integration into complex experimental setup

Easy integration into complex experimental setup NIRvana: 64ST The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications.

More information

Spectral imagers for nanosatellites

Spectral imagers for nanosatellites VTT TECHNICAL RESEARCH CENTRE OF FINLAND LTD Spectral imagers for nanosatellites Finnish Satellite Workshop 2018 Antti Näsilä VTT Microspectrometers Fabry-Perot (FPI) technology for miniaturizing optical

More information

Micro Raman Measurement system

Micro Raman Measurement system Ramboss-500i Micro Raman Measurement system Features High performance confocal spectroscopic micro sample chamber 1um beam spot size and 1um step mapping resolution Raman shift resolution : 2cm-1 @632.8nm,

More information

Section V: AD Series Detection Systems

Section V: AD Series Detection Systems Section V: AD Series AD110B 0B Photobyte - P System AD131 Photodetector Module Cooled CCD Cameras AD202 AD205 AD206 Kestr estralspec Softwar are Data Acquisition 57 AD110B Photob obyte - P Photomultiplier

More information

Modular Raman Spectrometers

Modular Raman Spectrometers Modular Raman Flexible Raman from the Raman Experts horiba.com/scientific Flexible and Affordable Raman The new range of modular Raman spectrometers from HORIBA Scientific allows the user to have a flexible

More information

FLEX 2 NEW. Key points. 3D Confocal Raman, 2 lasers, fiber based, AFM combined

FLEX 2 NEW. Key points. 3D Confocal Raman, 2 lasers, fiber based, AFM combined FLEX 2 3D Confocal Raman, 2 lasers, fiber based, AFM combined NEW Key points Compact size 2 lasers, easily switchable 2 confocal operation modes, easily switchable : High Spatial Resolution 35 nm High

More information

Simple Spectrograph. grating. slit. camera lens. collimator. primary

Simple Spectrograph. grating. slit. camera lens. collimator. primary Simple Spectrograph slit grating camera lens collimator primary Notes: 1) For ease of sketching, this shows a transmissive system (refracting telescope, transmission grating). Most telescopes use a reflecting

More information

Newton EMCCD. Specifications Summary 1. Output node well depth (typical) High Sensitivity mode Electron Multiplying mode

Newton EMCCD. Specifications Summary 1. Output node well depth (typical) High Sensitivity mode Electron Multiplying mode NEW NOW AVAILABLE WITH ANTI-FRINGING BACK THINNED TECHNOLOGY Spectroscopy Features and Benefits EM sensor technology

More information

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC Raman KPFM AFM AFM-Raman characterization of PS-PVAC polymer blend film SPECTRUM The world s first fully automated Raman AFM AFM - confocal Raman - SNOM - TERS The first fully integrated & automated AFM

More information

600 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

600 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical) Quantum efficiency (%) 100 90 80 70 60 50 40 30 Spectroscopy 20 10 0 0.6 0.8 1 1.2 1.4 1.6 1.8 Wavelength (µm) Features and Benefits 0.6 to 1.7 μm Operating wavelength range Peak QE of > 85% High detector

More information

Hyperchromator. Operation Manual Version 1 March 2018

Hyperchromator. Operation Manual Version 1 March 2018 Hyperchromator Operation Manual Version 1 March 2018 Copyright 2018 Mountain Photonics GmbH. All rights reserved. All technical information, including drawings, schematics and specifications contained

More information

C101-E115. Talk Letter. Vol.3 November 2009

C101-E115. Talk Letter. Vol.3 November 2009 C101-E115 UV Talk Letter Vol.3 November 2009 UV UV Talk Letter Monochromators Talk Letter Vol.3 November 2009 In this volume, we will describe the monochromator, an important part of the spectrophotometer

More information

UHD 185 FAQs. Optical System

UHD 185 FAQs. Optical System UHD 185 FAQs System Setup How is a typical setup of the UHD 185? Is a wireless control during flight possible? How do I trigger the image acquisition? What is the power consumption? What are the specs

More information

High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology

High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology 2015 Princeton Instruments, Inc. All rights reserved. High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology The PI-MAX4:1024EMB emiccd camera seamlessly

More information

Characterization of MKIV Brewer #066 for NO 2 measurements

Characterization of MKIV Brewer #066 for NO 2 measurements Characterization of MKIV Brewer #066 for NO 2 measurements Henri Diémoz Regional Environmental Protection Agency (ARPA) Valle d Aosta (Italy) Sapienza - University of Rome Brewer Users Meeting Beijing,

More information

Acton Research Corporation SpectraPro Monochromator Control Software for Windows

Acton Research Corporation SpectraPro Monochromator Control Software for Windows 530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Acton Research Corporation SpectraPro Monochromator Control Software for Windows Ver 2.0 2 Contents

More information

Optical Engineering. Course outline. Exercise: Selection of telescope

Optical Engineering. Course outline. Exercise: Selection of telescope Course outline 4. Optical Engineering Martina Gerken..007 Universität Karlsruhe (TH). Imaging optics. ight propagation across interfaces. Photography and optical lenses.3 Aberrations.4 Plane parallel plates

More information

Using Adjustable Slits to Reduce Interfering Element Effects

Using Adjustable Slits to Reduce Interfering Element Effects Prodigy ICP Technical Note Using Adjustable Slits to Reduce Interfering Element Effects INTRODUCTION The Inductively Coupled Plasma (ICP) is one of the most widely used emission sources for routine trace

More information

Tutorial Solutions. 10 Holographic Applications Holographic Zone-Plate

Tutorial Solutions. 10 Holographic Applications Holographic Zone-Plate 10 Holographic Applications 10.1 Holographic Zone-Plate Tutorial Solutions Show that if the intensity pattern for on on-axis holographic lens is recorded in lithographic film, then a one-plate results.

More information

Progress of the Thomson Scattering Experiment on HSX

Progress of the Thomson Scattering Experiment on HSX Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison, The Thomson scattering system being constructed

More information

axis, and wavelength tuning is achieved by translating the grating along a scan direction parallel to the x

axis, and wavelength tuning is achieved by translating the grating along a scan direction parallel to the x Exponential-Grating Monochromator Kenneth C. Johnson, October 0, 08 Abstract A monochromator optical design is described, which comprises a grazing-incidence reflection and two grazing-incidence mirrors,

More information

Grating Spectrometer GRATING.TEX KB

Grating Spectrometer GRATING.TEX KB UNIVERSITÄTK OSNABRÜCK 1 Grating Spectrometer GRATING.TEX KB 20020119 KLAUS BETZLER 1,FACHBEREICH PHYSIK, UNIVERSITÄT OSNABRÜCK This short lecture note recalls some of the well-known properties of spectrometers.

More information

PHYSICS 213 PRACTICE EXAM 3*

PHYSICS 213 PRACTICE EXAM 3* PHYSICS 213 PRACTICE EXAM 3* *The actual exam will contain EIGHT multiple choice quiz-type questions covering concepts from lecture (16 points), ONE essay-type question covering an important fundamental

More information

Red Tide USB650 Fiber Optic Spectrometer. Installation and Operation Manual Document Number RT

Red Tide USB650 Fiber Optic Spectrometer. Installation and Operation Manual Document Number RT 1. Red Tide USB650 Fiber Optic Spectrometer Installation and Operation Manual Document Number 170-00000-RT-02-1106 Offices: Ocean Optics, Inc. World Headquarters 830 Douglas Ave., Dunedin, FL, USA 34698

More information

PVE300 Photovoltaic EQE & IQE Solution

PVE300 Photovoltaic EQE & IQE Solution . Photovoltaic EQE & IQE Solution Bentham.co.uk EQE testing of photovoltaic devices allows you to determine where your device wins and loses throughout the spectrum and gives you an insight into the physical

More information

Ocean Optics. Product Information

Ocean Optics. Product Information Ocean Optics Product Information Doesn t That Sound Good? Introducing the World s Coolest Modular Measuring Suite Talk about innovation in optical sensing! Jaz is like nothing you ve ever seen before --

More information

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question IGOV kenniscafé Arnhem, 31 oktober 2013 Peter Hanselaer Light&Lighting Laboratory Introduction Spectral

More information

SYNCERITY TM 1024 x 256

SYNCERITY TM 1024 x 256 ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING SYNCERITY TM 1024 x 256 Open-Electrode TE-Cooled CCD

More information

idus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88

idus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88 Spectroscopy Features and Benefits Peak QE of 95% High detector sensitivity TE cooling to 100 C Negligible dark current without the inconvenience of LN 2 UltraVac 1 Permanent vacuum integrity, critical

More information

Investigation of an Alternative Method for Measuring the Spectral Irradiance of a High-Powered Focused Light Source

Investigation of an Alternative Method for Measuring the Spectral Irradiance of a High-Powered Focused Light Source Investigation of an Alternative Method for Measuring the Spectral Irradiance of a High-Powered Focused Light Source Speaker / Author: I. Kruger * Co-author: R. Sieberhagen ** National Metrology Institute

More information

Company Presentation Optical Components

Company Presentation Optical Components Company Presentation Optical Components A selection of our partners 2 A selection of our partners 3 Optical Technologies Fiber Optics components & fiber optic assemblies Precision optics Acousto-optics

More information

Thermo Scientific DXR2 Raman Family

Thermo Scientific DXR2 Raman Family MOLECULAR SPECTROSCOPY Thermo Scientific DXR2 Raman Family Focus on answers, not the technique Product Specifications Easily adapt to any sample challenge using the Thermo Scientific DXR 2 family of Raman

More information

800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)

800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical) Quantum efficiency (%) 100 90 80 70 60 50 40 30 Spectroscopy 20 10 0 1 1.2 1.4 1.6 1.8 2 2.2 2.4 Wavelength (µm) Features and Benefits 0.8 to 2.2 μm Operating wavelength range Peak QE of > 70% High detector

More information