Shamrock 303i. Resolution with Newton DU940 CCD nm nm. Aperture F/4
|
|
- Brent Bates
- 5 years ago
- Views:
Transcription
1 New photograph required Spectroscopy Features and Benefits Pre-aligned, pre-calibrated detector & spectrograph Motorized, individually factory-calibrated systems out-of-the-box operation and seamless integration to experimental set-ups Image astigmatism correction Optimized toroidal optics enabling high density multi-track capabilities USB 2.0 interface Plug and play connectivity, ideal for laptop operation alongside Andor USB cameras Motorized, indexed triple grating turret Easily upgradable in-the-field Dual detector outputs For extended wavelength coverage when combining Andor UV-Visible CCD and InGaAs cameras Compatible with Andor s range of CCD, ICCD & EMCCD cameras Wide range of accessories available The ultimate in modular set-up and in-field upgradability, including: - Motorized slits & filter wheel - Microscope interfaces - Shutters - Fibre-optic & lens couplers - Multi-way fibre-optic bundles - Light sources and optics Silver-protected coated optics option Most efficient for Near-Infrared detection when used in conjunction with Andor InGaAs cameras Research-grade high performance spectrograph The Shamrock 303i spectrograph is a research-grade, high performance and rugged platform designed for working with demanding low-light applications, but equally suited to day-to-day routine measurements. It is a highly versatile platform configurable seamlessly with a wide range of light coupling interfaces and gratings upgradeable in-the-field. The Shamrock 303i can be seamlessly integrated with Andor s world-class range of CCDs, Electron-Multiplying CCDs, InGaAs and Intensified CCDs to offer a versatile, yet most sensitive modular solutions on the market. Andor Solis software offers the most user-friendly and state-of-the-art real-time control of detectors, spectrograph and motorized accessories at the touch of a button. Specifications Summary Resolution with Newton DU940 CCD nm nm 0.10 nm 0.05 nm Aperture F/4 Focal length 303 mm centre of CCD Vertical, spectral flange Vertical, multi-track flange 1 1 Gratings Interchangeable indexed triple turret Slit width range (input/output) Motorized 10 µm to 2.5 mm Wide aperture option to 12 mm Communication USB 2.0 Wavelength accuracy 0.04 nm Wavelength repeatability 4 pm Stray light 2.2 x 10-5 Page 1 of 12
2 Step-by-Step System Configuration How to customize the Shamrock 303i : Side output (B) Step 4. 2 nd output port configuration Step 2. Resolution & band-pass Direct output (A) Step 1. Chassis configuration Side input Step 3. Input light coupling interface Step 1. - Chassis configuration a) Select either a single output port (model A) or dual output port (model B) option. b) Select type of optics coating required (aluminium + MgF 2 is standard, protected silver coated optics available on request for NIR detection). c) Select purge port option (for extended detection below 180 nm), and shutter for background acquisition and detectors protection. Step 2. - Resolution & band-pass a) Select the appropriate Shamrock spectrograph platform, giving due consideration to bandpass and spectral range requirement. b) Select gratings and detector to fulfill resolution requirements. c) Select gratings for suitable wavelength coverage. Step 3. - Input light coupling interface Refer to accessory tree for available configurations (direct coupling, fibre coupling or 3 rd party hardware connectivity). Step nd exit port configuration Refer to accessory tree for available configurations, including camera flanges. Step 5. - Software interface Select either state-of-the-art Solis software or Software Development Kit (SDK) option please refer to appropriate section for futher information. Page 2 of 12
3 Step 1 - Chassis Configuration Ordering Information Model Side input port Direct output port Side output port Motorized flipper mirror SR-303i-A Motorized slit Camera - - SR-303i-B Motorized slit Camera Camera (standard) Optional motorized slit SR-303i-X-SIL Protected silver coated optics for models shown above (replace X with relevant model number) Optics Coatings Reflectivity Graph Optics coatings reflectivity data The graph shows the standard Al + MgF 2 optics coatings reflection efficiency versus 98 wavelengths. Reflectivity (%) Protected silver coated optics Aluminium & MgF 2 Protected silver coated optics option is also available on request for maximum efficiency in the NIR region and is recommended for working with Andor idus InGaAs detectors. When choosing protected silver coatings, it is strongly recommended to also order protected silver coated gratings for maximum efficiency throughout the system Chassis Accessories Additional Grating Turret 1 (SR-ASM-0003) New istar I 2 C to BNC shutter cable (ELC-05323) Purge Connector (SR-ASM-8040) Shutter (SR-SHT-9001) Adjustable Feet (set of 4) (SR-ASM-0022) I 2 C and USB Cables (Standard) Page 3 of 12
4 Step 2a - Choosing The Right Platform vs Dispersion Requirements Resolution calculator /calculators Green Aberration-free region Orange Possible impact on system resolution Red Likely impact on system resolution Czerny-Turner spectrographs are designed to provide the best optical performance for a range of grating angles as indicated by the green parts of the graph above. Outside this range, the spectral lines may exhibit a degree of optical aberration (such as coma), which will become more prominent at the steeper angles. These configurations are indicated by the orange to red scales on the graph. In these regions, consideration should be given to higher spectrograph focal length models with lower groove density gratings to achieve the desired resolution. Grating (l/mm) Shamrock (Holo) 2400 (Holo) Bandpass (nm) 2, Resolution (nm) 3, Shamrock 303i Bandpass (nm) 2, Resolution (nm) 3, Shamrock 500i Bandpass (nm) 2, Resolution (nm) 3, Shamrock 750 Bandpass (nm) 2, Resolution (nm) 3, Where aberration is a concern for a particular experimental set-up, the table above shows resolution and band-pass performance for a variety of alternative configurations. This should be used in conjunction with the graph above to assist in selecting the most appropriate Shamrock spectrogrph platform to meet resolution and band-pass needs, whilst minimising the risk of potential aberration. Page 4 of 12
5 Step 2b - Choosing The Right Grating vs Resolution & Band-pass The Shamrock 303i features an innovative triple grating turret, designed to offer flexibility and control over your choice and interchange of gratings. The triple grating turret can be easily and speedily removed, and replaced by an alternative turret with new gratings. The intelligent design of the 303i means that only a simple offset adjustment is required once the new turret and gratings are added. The 303i is shipped with the grating turret already in place, ensuring your system is ready for use straight out of the box. Additional grating turrets are available with up to three pre-installed gratings per turret (see below for details). If the grating you require is not on the list, please contact Andor for further details. Additional grating turret(s) (part number SR-ASM-0003) can also be supplied on request. Lines/mm Blaze (nm) Nominal dispersion (nm/mm) 6 Bandpass (nm) 2, 6 Resolution (nm) 3, 6, 9 Peak efficiency (%) Andor part number Maximum recommended wavelength (nm) Maximum attainable wavelength (nm) SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT SR3-GRT (@1600) SR3-GRT SR3-GRT (@ 800) Holographic (500 nm peak) Holographic (250 nm peak) Holographic (380 nm peak) SR3-GRT SR3-GRT-1200-EH* SR3-GRT-1800-DH SR3-GRT-1800-FH SR3-GRT Holographic (220 nm peak) Holographic (400 nm peak) SR3-GRT-2400-BH SR3-GRT-2400-GH Mirror UV-VIS SR3-GRT-MR-AL-MGF2 Mirror VIS-NIR SR3-GRT-MR-SILVER *Option for minimized scattered light. Need to have maximum collection efficiency in the NIR/SWIR? All gratings are also available with protected silver coating. Please contact your local representative for further information. Page 5 of 12
6 Step 2c - Selecting The Correct Grating Efficiency Option All graphs shown below represent efficiency for 45 polarisation Efficiency (%) 150 l/mm - Ruled 2000 nm nm 800 nm nm nm Efficiency (%) 300 l/mm - Ruled nm 1200 nm nm 1700 nm nm Efficiency (%) nm nm l/mm - Ruled 1900 nm 1200 nm 0 nm Efficiency (%) nm 300 nm 1200 l/mm - Ruled & Holographic Holographic (EH) Optimised for nm 0 nm Efficiency (%) l/mm - Holographic Holographic (FH) Optimised for nm Holographic (DH) Optimised for nm Efficiency (%) l/mm - Ruled & Holographic Holographic (GH) Optimised for nm Holographic (BH) Optimised for nm nm Important Consideration System throughput is dependent on the grating s angle of operation and may decrease with higher grating operating angles. Page 6 of 12
7 Step 3 - Selecting The Correct Light Coupling Interfaces How to customize the Shamrock 303i : Side input port Spacer (Standard) Filter Wheel Assembly (SR-ASZ-7001) Neutral Density Filters 11 Long Pass Filters 11 Short Pass Filters 11 Raman Edge Filters 11 Fixed FC Fibre Adapter (SR-ASM-8011) Fixed SMA Fibre Adapter (ACC-SR-ASM-8003) Y Adjustable Fast Kinetics Fibre Adapter, SMA Input (SR-ASM-8012) Motorized Slit Assembly 12 (Standard) inc 6 x 4 mm (W x H) Cover Plate Motorized Wide Aperture Slit 13 (ACC-SR-ASZ-0034) inc Ø27 mm Cover Plate X-Y Adjustable Fibre Adapter (See page 9 Section B: Direct X-Y fibre couplers) SMA Fibre (50 µm: ACC-ME-OPT-8004) ( µm: SR-OPT-8039) Cover Plate for Motorized Slit Assembly (See page 9 Section A: Slit Covers) Sample Chamber (ACC-SR-ASZ-0056) 11 F/# Matcher for NA = 0.22 Fibre (SR-ASM-0038) 10 X Adjustable Fibre Adapter, Ferrule Input (SR-ASM-8006) Fixed Fibre Adapter, Ferrule Input (SR-ASM-8001) X-Y Adjustable Fibre Adapter (See page 9 Section C: X-Y fibre couplers with slit assembly) Optical Cage System Adapter (SR-ASM-0065) F-Mount Camera Lens Adapter (SR-ASM-0013) 1.5 Flange Adapter for Newport Oriel Accessories (SR-ASM-0002) C-Mount Adapter (SR-ASM-0021) Pen-Ray Lamp Mount (SR-ASM-0014) SMA Adapter for F/# Matcher (SR-ASM-0041) FC Adapter for F/# Matcher (SR-ASM-0064) 11 Fibre Ferrule (SR-OPT-80XX) 11 Cage System (Please refer to Thorlabs or Linos catalogue) F-Mount Lens 11 Pen-Ray Lamp 11 Hg-Ar, Hg-Ne, Ar, Kr, Ne SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004) ( µm: SR-OPT-8039) Cage system microscope flange (TR-XXXX-CAGE-ADP) 11 SR-ASZ-0079 Optical Relay C-Mount Lens (OL-XXXX-XXX) 11 Page 7 of 12
8 Step 4 - Cameras & Output Port Flanges How to customize the Shamrock 303i : Side Output Port X-Y Adjustable Fibre Adapter See page 9 Section B: Direct X-Y fibre couplers Exit Port Motorized Slit Assembly 12 (SR-ASZ-0005) inc 6 x 4 mm (W x H) Cover Plate Direct connection of Andor spectroscopy cameras (no need for flange) Cover Plate for Motorized Slit Assembly (See page 9 Section A: Slit Covers) X-Y Adjustable Fibre Adapter See page 9 Section C: X-Y fibre couplers (with slit assembly) C-Mount Adapter (SR-ASM-0021) Sample Chamber (ACC-SR-ASZ-0056) 11 Direct Output Port ikon-l Mounting Flange (MFL-SR303i-IKON-L) 14 ikon-m Mounting Flange (MFL-SR303i-IKON-M) Intermediate Plane Multi-channel Detector Flange (MFL-SR303i-INTER) ixon Mounting Flange (MFL-SR303i-IXON) 15 ixon 888 Mounting Flange (MFL-SR303i-888) 15 ixon 888 Mounting Flange Crop Mode & Fast Kinetics (MFL-SR303i-888-CROP) 15 Multi-channel Detector Flange (Standard) Page 8 of 12
9 A: Slit Covers B: Direct X-Y Fibre Couplers Cover Plate Apertures for Motorized Slit Part No. Size SR-ASM x 8 mm (W x H) SR-ASM x 14 mm (W x H) SR-ASM Ø 15 mm SR-ASM x 4 mm (W x H) SR-ASM x 6 mm (W x H) FC: SR-ASM FC-APC: SR-ASM SMA: SR-ASM-8054 Ferrule: SR-ASM-8057 FC upgrade: ACC-FC-DIRECT-APT FC/APC upgrade: ACC-FCAPC-DIRECT-APT SMA upgrade: ACC-SMA-DIRECT-APT SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004) ( µm: SR-OPT-8039) Fibre Ferrule (SR-OPT-80XX) 11 C: X-Y Fibre Couplers (with Slit Assembly) FC: SR-ASM SMA: SR-ASM-8052 Ferrule SR-ASM-8069 FC upgrade: ACC-FC-SLIT-APT SMA upgrade: ACC-SMA-SLIT-APT Ferrule upgrade: ACC-FERRULE-SLIT-APT Fibre Ferrule (SR-OPT-80XX) 11 SMA - SMA Fibre (50 µm: ACC-ME-OPT-8004) ( µm: SR-OPT-8039) Page 9 of 12
10 Step 5 - Selecting A Software Option The Shamrock 303i requires at least one of the following software options: 1 - Solis Spectroscopy A 32-bit Windows application (XP, Vista and 7) offering rich functionality for data acquisition and processing, as well as Andor cameras, spectrograph and motorized accessories simultaneous control. AndorBasic provides macro language control of data acquisition, processing, display and export. 2 - Standalone Solis Spectroscopy GUI for standalone spectrograph operation 3 - Andor SDK software development kit that allows you to control the Andor range of Shamrock spectrographs from your own application. Compatible as 32 bit libraries for Windows (XP, Vista and 7). Compatible with C/C++, C#, VB6 and LabVIEW. Solis dedicated spectroscopy acquisition interface and hardware control panel Example of fluorescence spectrum acquisition Real Time Control (a) (b) (c) (d) (e) (a) Slit drive: Control the spectrograph slit width - drag blades on icon or type in required slit width (b) Flipper motor: Used to select the appropriate exit port (c) Shutter: Synchronization mode selection for shutter operation (d) Filter wheel: Used to select a particular filter on the filter wheel - just click on the desired filter position (e) Grating turret: Used for setting grating turret to a new position and bringing desired grating in the optical path - just click on the desired grating Wavelength drive: Sets the wavelength range for the current grating - drag slider to desired wavelength or just type in appropriate value Exposure time: Sets the exposure time for the detector - quick access for easy acquisition optimization Page 10 of 12
11 Product Drawings Dimensions in mm [inches] Third-angle projection Optical Axis 127 mm [5 ] with pad feet The optical path height is shown with standard feet attached. The height with adjustable feet SR-ASM-0022 varies from 143 mm [5.6 ] to 173 mm [6.8 ] Screw Type Requirements CCD flange to Spectrograph flange 4 off, M4 x 16 Camera to CCD flange 4 off, M3 x 10 ixon camera to ixon flange 4 off, M5 x 10, countersunk, hex head Connecting to the Shamrock 303i Wavelength Drive Performance Wavelength accuracy 18 Center 0.04 nm USB Shamrock Control Connector type: USB B type Wavelength repeatability 19 4 pm I 2 C Interface Connector type: 5-pin, 1 = I 2 C data, 2 = I 2 C clock, 3 = Earth, 4 = Shutter TTL, 5 = 5 V Shutter Specifications Maximum repetition rate 2 Hz Shutter Control Connector type: BNC Female, 50 Ω Minimum open/close time Minimum lifetime 15 ms Better than K cycles Applications Guide Absorption-Transmission-Reflection Raman (Stimulated, Resonance, CARS, SERS, SORS, TERS) Fluorescence -Luminescence Micro-Fluorescence Photon Counting Single Molecule Spectroscopy Plasma Studies & LIBS Plasmonics Optical Properties Focal plane size (mm, W x H) 28 x 14 Stray light 20 FVB (1 nm from laser) FVB (10 nm from laser) 1 mm strip (1 nm from laser) 1 mm strip (10 nm from laser) 8.3 x x x x 10-5 Wavelength Side Accuracy Wavelength side accuracy nm Page 11 of 12
12 Typical Setup - Spectroscopy Typical Setup - Microspectroscopy Microscope Alternative Detector (e.g. idus InGaAs) Shamrock 303i Spectrograph Alternative Detector (e.g. idus) Shamrock 303i Spectrograph Lens Newton EMCCD PC Cage System Lamp Software CD Newton EMCCD Microscope Feet Page 12 of 12
13 Order Today Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our local sales offices, please see: /contact Our regional headquarters are: Europe Belfast, Northern Ireland Japan Tokyo Phone +44 (28) Phone +81 (3) Fax +44 (28) Fax +81 (3) North America China Connecticut, USA Beijing Phone +1 (860) Phone +86 (10) Fax +1 (860) Fax +86 (10) Items shipped with your spectrograph 1x 3 m USB 2.0 cable Type A à Type B 1x Power supply with 3 m mains cable 1x PCI / I 2 C cable 1x Camera / spectrograph I 2 C cable 1x CD containing Andor user guides 1x Individual system performance booklet 1x CD containing either Solis software or SDK (if requested at time of order) 1x Allen key set (2 mm, 3 mm & 5 mm) Regulatory Compliance Compliant with the requirements of the EU EMC and LV Directives, compliant with the international EMC and safety standards IEC and IEC Footnotes: Specifications are subject to change without notice 1. In the case of a multiple grating turret order, please specify desired grating configuration for each turret. 2. Typical values quoted with 27.6 mm wide CCD, e.g. Newton DU Typical values quoted with 10 μm slit and 13.5 μm pixel CCD, e.g. Newton DU Typical values 500 nm centre wavelength. 5. Typical values 300 nm centre wavelength. 6. Typical values quoted at maximum efficiency wavelength or blaze wavelength unless otherwise stated. 7. Wavelength within the recommended operating spectral region. 8. Indicative values; the working range of these gratings is principally in the region where optical aberrations may alter the system resolution performance quoted. 9. Values shown are representative of a triple grating system, where resolution has been optimised to give the best performance for the three gratings and across the full recommended wavelength range. Useful signal is assumed to be imaged on the entire height of a 6.9 mm sensor (i.e. Newton DU940) and fully vertically binned. 10. Please refer to F/# matcher specification sheet for magnification considerations. 11. Please refer to the local sales representative or website for further information on available options and complimentary accessories. 12. Slit widths range from 10 μm to 2.5 mm motorized. 13. Slit widths range from 10 μm to 2.5 mm motorized (full opening at 12 mm manually for wide aperture slit. Standard slit cover aperture is Ø 27 mm. 14. Require shutterless camera models. Please contact your local representative for further information. 15. Additional I 2 C cable (ELC-00648) is required when operating Shamrock 303i with these cameras. 16. Recommended for use with fibre-optics and C-mount accessories. 17. Provided as standard. 18. Average measurements using > 30 calibration lines, covering the recommended grating angle operating range with a 1200 l/mm grating. 19. The standard deviation of 20 measurements of a peak s centre-of-mass position: between each measurement the drive is moved 10x including both wavelength and grating changes to reflect typical use. 20. Measured with a 633 nm laser and a 1200 l/mm grating for Full Vertical Binning (FVB) on a 6.9 mm high sensor, and a 1 mm strip vertically centred on the optical axis. 21. Side accuracy measured using a 27.6 mm wide sensor, reflecting the dispersion calibration and step-andglue accuracy. Minimum Computer Requirements: 3.0 GHz single core or 2.4 GHz multi core processor 2 GB RAM MB free hard disc to install software (at least 1 GB recommended for data spooling) USB 2.0 High Speed Host Controller capable of sustained rate of 40 MB/s Windows (XP, Vista and 7) Operating & Storage Conditions Operating Temperature 0 C to 30 C ambient Relative Humidity < 70% (non-condensing) Storage Temperature -25 C to 50 C Power Requirements Vac, Hz Windows is a registered trademark of Microsoft Corporation. Labview is a registered trademark of National Instruments. Matlab is a registered trademark of The MathWorks Inc. SShamrock303iSS 1112 R1 Page 13 of 12
195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195.
Hg-Ar spectrum Acquired with Mechelle 5000, 104 x 104 pixel Gen Andor istar and 10 µm slit width Spectroscopy Features and Benefits Compact and robust design with no moving components Ideal for non-lab
More informationSpecifications. Wavelength range (nm) Focal length (mm) 195. Aperture F/7. Spectral resolution (λ/ λ) 1 (corresponding to 3 pixels FWHM)
Spectroscopy Hg-Ar spectrum Acquired with Mechelle 5000, 1024 x 1024 pixel Gen 2 Andor istar and 10 µm slit width Features and Benefits Compact and robust design with no moving components Ideal for non-lab
More informationNewton EMCCD. Specifications Summary 1. Output node well depth (typical) High Sensitivity mode Electron Multiplying mode
NEW NOW AVAILABLE WITH ANTI-FRINGING BACK THINNED TECHNOLOGY Spectroscopy Features and Benefits EM sensor technology
More information800 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)
Quantum efficiency (%) 100 90 80 70 60 50 40 30 Spectroscopy 20 10 0 1 1.2 1.4 1.6 1.8 2 2.2 2.4 Wavelength (µm) Features and Benefits 0.8 to 2.2 μm Operating wavelength range Peak QE of > 70% High detector
More information25.6 mm wide / 1600 pixel, 3 MHz Spectroscopy EMCCD. Specifications Summary 1. Output node well depth: Conventional mode Electron Multiplying mode
Features and Benefits EM sensor technology
More informationscmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary
Ultra Sensitive Imaging Low Light Imaging Features and Benefits Compact and light Ideal for integration into space restrictive set-ups 1.2 e - read noise Lower detection limit than any CCD 5.5 megapixel
More informationidus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88
Spectroscopy Features and Benefits Peak QE of 95% High detector sensitivity TE cooling to 100 C Negligible dark current without the inconvenience of LN 2 UltraVac 1 Permanent vacuum integrity, critical
More informationSpectrograph overview:
High performance measurement systems Monochromator Family Gilden Photonics offers a range of integrated optical wavelength solutions in customized designs, OEM design, manufacturing and value added resell
More information600 nm µm Spectroscopy InGaAs PDA. Specifications Summary. Active pixels 512 or Pixel well depth (typical)
Quantum efficiency (%) 100 90 80 70 60 50 40 30 Spectroscopy 20 10 0 0.6 0.8 1 1.2 1.4 1.6 1.8 Wavelength (µm) Features and Benefits 0.6 to 1.7 μm Operating wavelength range Peak QE of > 85% High detector
More informationandor.com Scientific CMOS - Fast, sensitive, compact and light Features and Benefits Specifications Summary Ultra Sensitive Imaging Low Light Imaging
Interline CCD 5.5 e - read noise Andor scmos 1.2 e - read noise Low Light Imaging Ultra Sensitive Imaging Upgrading to Zyla scmos can radically improve the performance of your fluorescence microscope Features
More informationSTANDARD SERIES MONOCHROMATOS FEATURES. Highly Customizable Modular Design. Two Configurable Input and Output Ports
STANDARD SERIES MONOCHROMATOS FEATURES Highly Customizable Modular Design Two Configurable Input and Output Ports Configurable turret and Grating Options USB2.0 Communication A Full Line of Input and Output
More informationImaging Spectrometers
JOBIN YVON Imaging Spectrometers ihr Series Uniquely shaped for uniquely superior performance. ihr Series Imaging Spectrometers A Unique Shape for a Unique Spectrometer The difference between ihr spectrometers
More informationConfocal Raman Systems SPECTROSCOPY GROUP
Confocal Raman Systems SPECTROSCOPY GROUP MonoVista CRS Configuration Option PIXIS TE-Cooled CCD Camera Acton Spectrograph Micro-Raman Interface Witness Camera Optional Laser Micro/Macro Transfer Optics
More informationSpecifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth (typical) 100,000 e -
Features and Benefits QE > 90% beyond 800 nm, optimized for NIR Very high detector sensitivity in near infra-red 5 MHz and 3 MHz readout speeds Rapid frame rates for high throughput cell inspection Dual
More information26.6 x 3.3 mm / 1024 x 127 pixel Spectroscopy CCD. Specifications Summary 2. Active pixels 1024 x 127. Register well depth (typical) 1,000,000 e -
Quantum efficiency (%) 0 90 80 70 60 50 40 30 BRDD New NOW AVAILABLE WITH ANTIFRINGING BACK THINNED TECHNOLOGY Spectroscopy 0 0 300 400 500 600 700 800 900 00 10 Wavelength (nm) Features and Benefits Peak
More informationWavelength (nm) Specifications Summary. Active pixels 512 x 512. Pixel size (W x H) 24 µm x 24 µm
QE (%) 100 90 BV 80 70 60 50 40 FI Low Light Imaging Low Light Imaging 30 20 Bioluminescence image showing an agar plate streaked with an Escherichia Coli strain containing bioluminescence genes 10 0 200
More information27 mm wide, 3 MHz Spectroscopy CCD. Spectroscopy at Pace. Specifications Summary 1. Register well depth:
Quantum efficiency (%) 100 90 80 70 60 50 40 30 BU BV, BVF BRDD BEX2DD New Antifringing BACK THINNED NOW AVAILABLE WITH & TECHNOLOGY Dual AR EXTENDED RANGE Spectroscopy 20 10 0 200 300 400 500 600 700
More information26.6 x 3.3 mm / 1024 x 127 pixel Spectroscopy CCD. Specifications Summary 2. Active pixels 1024 x 127. Register well depth (typical) 1,000,000 e -
Quantum efficiency (%) 0 90 80 70 60 50 40 30 BRDD Available with Antifringing BackIlluminated Technology Spectroscopy 20 0 200 300 400 500 600 700 800 900 00 10 1200 Wavelength (nm) Features and Benefits
More informationSpecifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Dark Current 2. Pixel Well Depth (typical) e e -
AVAILABLE WITH LOW NOISE & HIGH DYNAMIC RANGE sensor options Apogee Alta Series System Features 1 High Resolution Sensors 1.0 Megapixel sensor with large 24 mm pixels deliver a large field of view with
More informationSpecifications Summary 1. Array Size (pixels) Pixel Well Depth (typical) 94,000 e - Dark Current 2. Read Noise 3
Apogee Alta Series System Features 1 High Resolution Sensor 9.3 Megapixel sensor with 12 mm pixels delivers an exceptionally large field of view with high resolution. Programmable TE cooling down to 45
More informationSeries Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN
Series Spectrometers ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING ihr Series Imaging Spectrometers
More informationSYNCERITY TM 1024 x 256
ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING SYNCERITY TM 1024 x 256 Open-Electrode TE-Cooled CCD
More informationSpecifications Summary 3. Active pixels 2048 x Pixel size (W x H) 13.5 x 13.5 µm. Active area pixel well depth (typical) 100,000 e -
High Energy Detection Phase Contrast Tomography Pill Bug / Roly Poly Courtesy of Will Schumaker of the Center for Ultrafast Optical Science, University of Michigan, USA Features and Benefits Soft Dock
More informationMonochromator & Imaging Spectrograph
& Imaging Spectrograph Series Selection Guide Features 1. Interface : USB, and RS232C 2. s : 150mm, 200mm, 320mm, 500mm, and 750mm 3. Speed : Fast switching illuminator(galvanometer type) Slow scan (Stepper
More information27 mm wide, 3 MHz Spectroscopy CCD. Spectroscopy at Pace. Specifications Summary 1. Register well depth:
Quantum efficiency (%) 100 90 80 70 60 50 40 30 BU BV, BVF FI BU2 BRDD BEX2DD New Antifringing BACK THINNED NOW AVAILABLE WITH & TECHNOLOGY Dual AR EXTENDED RANGE Spectroscopy 20 10 OE UV 0 200 300 400
More informationTuCam. Features and Benefits. Andor TuCam - High Performance, Two Camera Imaging Adapter. Specifications Summary. Applications Guide
Ultra Sensitive Imaging Microscopy Systems Features and Benefits Largest aperture Unique 22 mm aperture for large format sensors e.g. Neo and Zyla scmos High quality achromatic lenses Image from 425 -
More information. Ideal for fast, shutterless imaging
IMAGING DV860 Andor s ixon DV860 EMCCD camera has single photon detection capability without an image intensifier, combined with greater than 90% QE of a sensor. Containing a 128x128 L3Vision TM Frame
More informationMonoVista CRS+ Raman Microscopes
MonoVista CRS+ Benefits Deep UV to NIR wavelength range Up to 4 integrated multi-line lasers plus port for large external lasers Dual beam path for UV and VIS/NIR Motorized Laser selection Auto Alignment
More informationLS-785 High Throughput Lens Spectrograph User Manual
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com LS-785 High Throughput Lens Spectrograph User Manual Ver. 1.2 Table of Contents Chapter 1 -- General...5
More informationCoherent kev Supercontinuum for Broad Element-Specificity. Courtesy of Dr. Daniil Kartashov. Specifications Summary 2. Register well depth
Coherent kev Supercontinuum for Broad ElementSpecificity. Courtesy of Dr. Daniil Kartashov Low Light Imaging High Energy Detection Features and Benefits Open front end 1 6 rotatable CF152 flange and knifeedge
More informationDV887 (back illuminated)
IMAGING Andor s ixon DV887 back illuminated EMCCD has single photon detection capability without an image intensifier, combined with greater than 90% QE of a back-illuminated sensor. Containing a 512x512
More informationihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise
ihr Series Research Grade Spectrometers Simply the best imaging spectrometers with no compromise horiba.com/osd Unmatched Flexibility in Applications HORIBA Scientific s Optical Spectroscopy Division
More informationNeo scmos. Specifications Summary. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 25,000 e - Pixel readout rate (MHz) 560, 400, 200
Interline CCD 5.5 e - read noise Low Light Imaging Low Light Imaging Andor scmos 1 e - read noise Features and Benefits 1 e - read noise Lower detection limit than any CCD 5.5 megapixel sensor format and
More informationOverview and History Research Focus OEM / Instrumentation Capability Lean Manufacturing principles andor Pioneering EMCCD Technology
corporate Overview and History As portrayed in our mission statement the principal business of Andor is the development and manufacture of high performance digital cameras. Further we look to share our
More informationCompatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.
PI-MAX 4: 1024f The PI-MAX4:1024f from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1k x 1k full-frame CCD fiberoptically coupled
More informationNeo scmos. Specifications Summary. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 30,000 e - Pixel readout rate (MHz) 560, 200
Interline CCD 5.5 e - read noise Low Light Imaging Ultra Sensitive Imaging Andor scmos 1 e - read noise Features and Benefits TE cooling to -40 C Minimization of dark current and pixel blemish 1 e - read
More informationistar 320T Series Features and Benefits Industry leading platform for nanosecond-scale, high-speed Spectroscopy Specifications Summary
TimeResolved ICCD TimeResolved Timeresolved Atomic species lifetime study. Courtesy of Laurent Philippet, Laboratoire de Physique des Lasers, CNRS, Paris 13 University. Features and Benefits USB 2.0 connection
More informationSpecifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth
Quantum efficiency (%) 100 90 80 70 60 50 40 30 BEX2-DD BV FI BU2 BR-DD New NOW AVAILABLE WITH Fringe Suppression & Low Light Imaging TECHNOLOGY Low Light Imaging Dual AR EXTENDED RANGE Ultra Sensitive
More informationPI-MAX 4: 1024 EMB. Applications:
The PI-MAX4: 1024 EMB from Princeton Instruments is the ultimate in ICCD technology. This innovative intensified EMCCD camera (emiccd) features back-illuminated 1024 x 1024 frame transfer EMCCD fiberoptically
More informationSpecifications Summary 2
Features and Benefits Overclocked to 17 MHz readout Industry fastest frame rates; 56 fps full frame. EX2 Technology Extended QE response TE cooling to -100 C Critical for elimination of dark current detection
More informationTuCam. Andor TuCam - High Performance, Two Camera Imaging Adapter. Features and Benefits. Specifications Summary.
Multi-Wavelength Imaging Features and Benefits Largest aperture Unique 22 mm aperture for large format sensors e.g. Neo and Zyla scmos High quality achromatic lenses Image from 425-700 nm with minimal
More informationPI-MAX 4: 1024 x 256
The PI-MAX4: 1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 253 pixel spectroscopy CCD fiber-coupled to
More informationSpecifications Summary 2
Features and Benefits Overclocked to 17 MHz readout Industry fastest frame rates; 56 fps full frame. EX2 Technology Extended QE response TE cooling to -100 C Critical for elimination of dark current detection
More informationSpecifications Summary. Active pixels 2048 x Active area pixel well depth 100,000 e - Maximum readout rate. Read noise 2.9 e - Maximum cooling
NEW NOW AVAILABLE WITH TWO NEW SENSORS UV/Blue Enhanced (BU2) & NIR Enhanced with Fringe Suppression (BR-DD) Ultra Low Sensitive Light Imaging Imaging Two interacting galaxies, M51 (Whirlpool Galaxy) &
More informationVideo frame rates and higher to efficiently synchronize with high repetition rate lasers
PI-MAX3:1024 x 256 The PI-MAX3:1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 256 spectroscopy CCD fiber-coupled
More informationSpecifications Summary. Aperture size. Transmission > 96% Application Guide. Real time multi color imaging. Co-localization
Multi-Wavelength Imaging Features and Benefits Largest aperture Unique 22 mm aperture for large format sensors e.g. Neo and Zyla scmos High quality achromatic lenses Image from 425-700 nm with minimal
More informationPI-MAX 4: 1024 x 256 SPECTROSCOPY GROUP
Powered by LightField The PI-MAX4: 1024 x 256 from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1024 x 253 pixel spectroscopy
More informationTABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE
TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CMOS TECHNICAL DATA SENSOR RESPONSE DIMENSIONS
More informationFEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy
PI-MAX3:1024i The PI-MAX3:1024i from Princeton Instruments is the next generation, fully-integrated scientific intensified CCD camera (ICCD) system featuring a 1k x 1k interline CCD fiberoptically coupled
More informationActon Research SpectruMM TM Complete Spectroscopic- Acquisition Systems
Acton Research SpectruMM TM Complete Spectroscopic- Acquisition Systems A fully integrated spectroscopy lab is as easy as 1, 2, 3... 1. High-Resolution CCD Detectors 2. Industry-Standard Acton Research
More informationTRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013
TRiCAM Time Resolved intensified CAMera The TRiCAM is a compact Intensified CCD camera for scientific and industrial applications that require 1) lowlight level imaging, 2) ultra-short exposures through
More informationRenishaw invia Raman Microscope (April 2006)
Renishaw invia Raman Microscope (April 2006) I. Starting the System 1. The main system unit is ON all the time. 2. Switch on the Leica microscope and light source for reflective bright field (BF) imaging.
More informationikon-xl 230 VERY LARGE AREA ASTRONOMY CCD P P P CCD NEW
ikon-xl 230 CCD VERY LARGE AREA ASTRONOMY CCD NEW -100 C TE Cooling (ColdSpace TM ) NO liquid nitrogen or cryo-cooler 18-bit Extended Dynamic Range Key Specifications 16.8 Megapixel sensor (CCD230-84)
More informationInstytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI
Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI I. Background theory. 1. Characteristics of the apparatus: prismatic, grating, interferometers. 2. Operating
More informationSpecifications Summary
TimeResolved OH PLIF CO PLIF CO + OH Reaction Rate 22 mm Example of TR Combustion Analysis Features and Benefits USB 2.0 connection Simple Plug & Play connection MultiMHz Readout speeds Rapid image capture
More informationPI-MAX 4: 1024i-RF. Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.
The PI-MAX4: 1024i-RF from Princeton Instruments is the ultimate scientific, intensified CCD camera (ICCD) system, featuring a 1k x 1k interline CCD fiberoptically coupled to Gen III filmless intensifiers.
More informationixon Specifications Summary Active pixels 128 x 128 Active area pixel well depth 250,000 e - Gain register pixel well depth 800,000 e -
Features and Benefits 513 full frames per sec Fast frame rates ideal for ion signalling microscopy and adaptive optics TE cooling to -100 C Critical for elimination of dark current detection limit OptAcquire
More informationSPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter
SPECTROMETERS USER MANUAL Making spectroscopy brighter 1 Table of contents 1. General Safety Rules... 2 2. Items Supplied... 2 3. Introduction... 3 4. Installation and Operation... 4 4.1. Notes... 7 5.
More informationSpecifications Summary 3. Active pixels 2048 x Pixel size (W x H) 13.5 µm x 13.5 µm. Active area pixel well depth. Maximum readout rate
NEW NOW AVAILABLE WITH DUAL AR EXTENDED RANGE & FRINGE SUPRESSION TECHNOLOGY Ultra Low Sensitive Light Imaging Imaging Features and Benefits Broad wavelength coverage Now available with BR-DD (red/nir),
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
LASERS FOR ANALYTICAL INSTRUMENTATION CW Lasers (Broad and Narrow Spectrum) Nanosecond SLM Lasers Accessories ADVANTAGES One size One control interface One voltage (+5 VDC) One software Many wavelengths
More informationTechnical Specifications for High speed PIV and High speed PIV-PLIF system
Technical Specifications for High speed PIV and High speed PIV-PLIF system MODULE A. HIGH SPEED PIV (3-C) A1. Double Cavity High Speed Laser (up to 10 khz): The vendor should provide Dual Head (DH) laser
More informationProEM -HS:1024BX3 FEATURES BENEFITS
The ProEM-HS: 124BX3 is the most advanced EMCCD camera on the market utilizing the latest low-noise readout electronics and a 124 x 124 EMCCD. This camera delivers single photon sensitivity and the best
More informationNeo scmos. Specifications Summary 2. Pixel size (W x H) 6.5 µm. Pixel well depth (typical) 30,000 e - Pixel readout rate (MHz) 560, 200
Interline CCD 5.5 e - read noise Interline CCD 5.5 e - read noise Andor scmos 1 e - read noise Low Light Imaging Ultra Sensitive Imaging Andor scmos 1 e - read noise Features and Benefits TE cooling to
More informationWAVELENGTH MANAGEMENT
BEAM DIAGNOS TICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS Camera Accessories WAVELENGTH MANAGEMENT UV CONVERTERS UV Converters
More informationProEM -HS:1KBX3-10µm
The ProEM-HS:1KBX3-1µm is the fastest EMCCD camera on the market utilizing the latest low-noise readout electronics and a 124 x 124 EMCCD. This camera delivers single photon sensitivity and the best fringe
More informationProEM -HS:1024BX3 FEATURES BENEFITS
ProEM -HS:124BX3 The ProEM-HS: 124BX3 is the most advanced EMCCD camera on the market utilizing the latest low-noise readout electronics and a 124 x 124 EMCCD. This camera delivers single photon sensitivity
More informationLever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com
Lever Your Genius Spectrograph & Accessories Datasheet FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has its own specially designed ecosystem
More informationNIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection
Powered by LightField The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy
More informationLever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com
Lever Your Genius Spectrograph & Accessories Datasheet FERGIE DATASHEET Highlights 2 FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has
More information20 MHz/16-bit readout 61 fps rate at full-frame resolution. Use ROI/binning for hundreds of frames per second.
ProEM -HS: 512BX3 The ProEM -HS: 512BX3 is the most advanced EMCCD camera on the market. It features Princeton Instruments patented excelon 3 technology which delivers the best combination of sensitivity,
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
LASERS FOR ANALYTICAL INSTRUMENTATION CW Lasers (Broad and Narrow Spectrum) Nanosecond SLM Lasers Accessories ADVANTAGES One size One control interface One voltage (+5 VDC) One software Many wavelengths
More informationINFINITY-CORRECTED TUBE LENSES
INFINITY-CORRECTED TUBE LENSES For use with Infinity-Corrected Objectives Available in Focal Lengths Used by Thorlabs, Nikon, Leica, Olympus, and Zeiss Designs for Widefield and Laser Scanning Applications
More informationFHR. Fully Automated. Imaging Spectrometer. User Manual
FHR Fully Automated Imaging Spectrometer User Manual Part Number 31505764 - Revision 1 Copyright April, 11 HORIBA Jobin Yvon Inc., Optical Spectroscopy Division. All rights reserved. Portions of the software
More informationEasy integration into complex experimental setup
NIRvana: 64ST The NIRvana: 64ST from Princeton Instruments is the world s first scientific grade, deep-cooled, large format InGaAs camera for low-light scientific SWIR imaging and spectroscopy applications.
More informationWAVELENGTH MANAGEMENT
Camera Accessories WAVELENGTH MANAGEMENT UV CONVERTERS UV Converters take advantage of a phenomenon called fluorescence to extend the performance range of the Beamage beam profiling camera to ultraviolet
More informationModular Raman Spectrometers
Modular Raman Flexible Raman from the Raman Experts horiba.com/scientific Flexible and Affordable Raman The new range of modular Raman spectrometers from HORIBA Scientific allows the user to have a flexible
More informationWinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent
Datasheet WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, 190 1610* nm * model-dependent With an 11.3 x 11.3 mm active area, 4.2 Mpixels, 5.5 x 5.5 μm pixels, optical and electronic triggering
More informationOperating Instructions OEM Spectrometer RU 60
OEM Spectrometer RU 60 JETI Technische Instrumente GmbH Tatzendpromenade 2 D-07745 Jena Tel. +49-3641-225 680 Fax. +49-3641-225 681 E-mail: sales@jeti.com Internet: www.jeti.com Table of contents 1. Features
More informationCATALOGUE INFRARED VIEWERS AND CAMERAS 2017
CATALOGUE INFRARED VIEWERS AND CAMERAS 2017 Wider spectral range IR viewers and cameras Content Spectral sensitivity... 26 Power density... 26 Content... 5 Technical information... 27 What s in the box?...
More informationikon-xl 231 VERY LARGE AREA ASTRONOMY CCD P P P P CCD NEW
ikon-xl 231 CCD VERY LARGE AREA ASTRONOMY CCD NEW Absolute BEST noise and well depth -100 C TE Cooling (ColdSpace TM ) NO liquid nitrogen or cryo-cooler 18-bit Extended Dynamic Range Key Specifications
More information1 MHz (2.4 e - ) 20 MHz (6.5 e - ) YEAR VACUUM WARRANTY. Pushing Interline Further. Specifications Summary. Active pixels (W x H) 1392 x 1040
1 MHz (2.4 e - ) 20 MHz (6.5 e - ) YEAR VACUUM WARRANTY Ultra Sensitive Imaging Comparative weakly fluorescent cell microscopy images showing sensitivity benefit of Clara ultra-low noise 1 MHz mode. Features
More informationMinimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.
Now Powered by LightField PyLoN:100 1340 x 100 The PyLoN :100 is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible
More informationillumia plus Light Measurement Systems
illumia plus Light Measurement Systems Flexible, modular solutions with centralized data management FLEXIBILITY Introducing Labsphere illumia plus light measurement systems flexibility to meet your most
More informationFrequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras
Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras Updated: Sep 2010 Includes information on excelon TM Back-illuminated Deep Depletion Cameras 1. What is excelon TM? excelon
More informationLever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com
Lever Your Genius Spectrograph & Accessories Datasheet FERGIE FERGIE is an integrated, aberration-free spectrograph with a built-in, lownoise, cooled detector. FERGIE has its own specially designed ecosystem
More informationOnline data sheet. TiM TiM5xx 2D LIDAR SENSORS
Online data sheet TiM571-501 TiM5xx TiM571-501 TiM5xx A B C D E F H I J K L M N O P Q R S T Detailed technical data Features Field of application Light source Ordering information Type Part no. TiM571-501
More informationBeam Analysis Camera Based Beam Propagation Analyzer: M Automatic M 2 - at Production Speeds. Manual M 2
3.7.1 Camera Based Beam Propagation Analyzer: M 2 ISO compliant Automatically measure your beam quality in under 1 minutes Tune your laser for best operation Specifically developed for continuous usage
More informationIMAGING GROUP. 512 x 512 imaging array; 24 mm x 24 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee
Now Powered by LightField PIXIS: 512 The PIXIS: 512 series of cameras from Princeton Instruments (PI) are fully integrated, low noise cameras designed expressly for quantitative scientific imaging applications.
More informationMore Precision. thermoimager TIM // Compact thermal imaging cameras
More Precision thermoimager TIM // Compact thermal imaging cameras 14 Thermal imaging camera for hot metal surfaces thermoimager thermoimager Short wavelength infrared camera for high temperature s of
More informationProgress of the Thomson Scattering Experiment on HSX
Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison, The Thomson scattering system being constructed
More informationVersatile laser Raman Spectrometer. RMP-500 series
Versatile laser Raman Spectrometer RMP-500 series About RMP-500 RMP-500 series is a compact and versatile laser Raman spectrometer consisting of a micro Raman probe connected through fiber optics to the
More informationOTO Photonics. Sidewinder TM Series Datasheet. Description
OTO Photonics Sidewinder TM Series Datasheet Description SW (Sidewinder TM ) Series spectrometer,built with the InGaAs type sensor and high performance 32bits RISC controller in, is specially designed
More informationLIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015
LIFA Fluorescence Lifetime Attachment LIFA 151A2 16/3/215 The LIFA is a dedicated system for Fluorescence Lifetime Imaging Microscopy (FLIM). It allows the generation of lifetime images on any widefield
More informationLt Megapixel High-Speed CMOS Camera with SuperSpeed USB 3.0
Lt225 2.2 Megapixel High-Speed CMOS Camera with SuperSpeed USB 3.0 High Resolution CMOS Sensor with Global Shutter Lumenera s Lt225 enclosed digital camera is built for rugged 24/7 use. A proven high resolution
More informationBack-illuminated scientific CMOS cameras. Datasheet
Back-illuminated scientific CMOS cameras Datasheet Breakthrough Technology KURO DATASHEET Highlights KURO, from Princeton Instruments, is the world s first backilluminated scientific CMOS (scmos) camera
More informationillumia Plus Light Measurement Sphere Systems
illumia Plus Light Measurement Sphere Systems Flexible, modular solutions with centralized data management Build a system that meets your needs Labsphere illumia Plus Light Measurement Systems offer flexibility
More informationPIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels
Powered by LightField PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels The PIXIS-XO series of fully integrated imaging cameras utilizes back illuminated and back illuminated deep depletion CCDs
More informationLASERS FOR ANALYTICAL INSTRUMENTATION
CW Lasers Combiners Q-switch Lasers >20 s MM/SM/PM fiber Single-frequency options 405 nm to 660 nm 4 wavelengths Open beam or Fiber 1029 nm / 514.5 nm High pulse energy Single Longitudinal Mode LASERS
More information4X Beam Expander P/N SPZ17022 and Optional Beam Splitter P/N SPZ17027 User Notes
4X Beam Expander P/N SPZ17022 and Optional Beam Splitter P/N SPZ17027 User Notes Ophir-Spiricon Inc. 60 West 1000 North Logan, UT 84321 For Sales, Service or Technical Support Phone (435) 753-3729 Fax
More informationPrizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications
Mic-LED-635 High Power Collimated Red LED Light Source for Fluorescence Microscopy Featuring Prizmatix Modular Design for Multi-Wavelength and Fiberoptic Setup Ver. 01 Introduction The compact Mic-LED-635,
More information