Power Supply. SIM Card. LED indicators

Size: px
Start display at page:

Download "Power Supply. SIM Card. LED indicators"

Transcription

1 Power Supply The GSM commutator is operates from a 12VDC power source. It draws less then 70mA standby, less then 350mA rms and 2A peak max. 12VDC/1.3A...2A switching stabilized power supply is recommended. Power supply input has reverse polarity and overvoltage protection. SIM Card Small SIM-card with 3V technology Preparation of SIM card 1. Delete any SMS messages from SIM. 2. Disable PIN code request so it will not prompt for a PIN code on turning on. 3. Write 3 authorized numbers to (position 1,2,3) You can to position 1 write number 99 or +99 for disable authorization numbers Note: The GSM Remote can only be used with small SIM-cards with 3V technology. For SIM card preparation you can use cell phone or external GSM modem. SIM card change if power turn off. LED indicators Module status indication - RED LED (LED1) GSM Modem SIM300 status indication - GREEN LED (LED2) Module LED indication (Red LED) LED status Permanently off Short blinking after power on and after 1 min periodic blinking Short blinking (period 5-6 sec) Permanently on Modem status Device off SIM card read process Module in work Module work with modem GSM Modem LED indication (Green LED) LED status Permanently off Fast blinking (period 1s, ton 0,5s) Slow blinking (period 3s, ton 0,3s) Permanently on Modem status Device off Net search / Not registered / Turning off Registered full service A call is active

2 Connectors and Jumpers Power supply (X2 - screw terminal block). Controlled equipment inputs and outputs (X2, X3, X4 - screw terminal block) SMA female connector (X5) for GSM antenna connection. Power Supply Connection +12VDC stabilized Power Supply must be connected with screw terminal block. We recommend use stabilized 1,3...2A 12VDC power supply. Power supply input has negative voltage and over voltage protection. Internal +12VDC connection and Power Supply connection schematic. Antenna connection GSM antenna must be connected to SMA connector X5. Use only the 50Om antenna of the necessary frequency range. Base version complected with direct mount GSM antenna. Note: It is very important that the antenna is installed on a location where the GSM-network coverage is sufficient. Please also check carefully that antennas are not installed nearby technical devices, cables etc which could influence the GSM-radiation.

3 Gate Automatic Connection For gate automatic control used relay output: Output 2 - alternative output for gate control. Output 1 and Output 4 - for optional use. Additional Interface Standard 2x3 pin ISP interface connector X1. Used only for in-system microcontroller programming. Pin Pin 1 MISO 2 VCC 3 SCK/ 4 MOSI 5 Reset/ 6 GND

4 Jumpers Jumper J2 Connection pull-up resistor to digital inputs. 2k2 resistor for each inputs is used. All resistor pulled up to +5V (+12V optional). Note: Use this jumper only for Open Collector or Relay Output.

5 Inputs / Outputs Schematic Inputs Digital Transistor Inputs Connector: Screw terminal block Inversion: Yes Protection: Yes Max input voltage: +12V without external limited resistor. Free Input: logic "0" Logic "0": 0V +1V Logic "1": +1.5V +12V J2 jumper for pull-up resistor connections to +12V (+5V optional) 0-10V / 0-5V Analog Inputs Connector: Screw terminal block Input type: CMOS Input Voltage: 0 to +10V Protection: Yes Input resistance: 100 KOm. ADC resolution: 10-bit 249 Om resistor optional for 0-20/4-20mA applications

6 Outputs MOSFET Open Drain Outputs Connector: Screw terminal block MOSFET transistor: Si9945 or IRF7103 Max. Voltage: 50V Relay Output Connector: Screw terminal block Outputs: NO/COM/NC Relay: SPDT power relay Breaking capacity: 5 A 230VAC / 28VDC Min load: 0.1 A, 5VDC

7 Connection Example Connection example to Input Driver (Input 1-5) 1-0 and 0-1 event notification You can use J2 pin header for in-board pull-up resistor connection. Relay connection example to Output Driver (Output 1, 2 and 5) Electromechanical relay connection. Solid-state-relay (SSR) connection.

8 Module programming For module programming: SIM card preparation Programming with send control SMS (see paragraph 'SMS Control Command List') SIM card preparation Delete any SMS messages from SIM. Write alarm SMS message to SIM (if you use alarm function) Disable PIN code request so it will not prompt for a PIN code on turning on. Write 2 authorized numbers to (position 1,2) Write gate open user cell phone numbers to (position from 3); you can added and deleted numbers with SMS command. Note: The module can only be used with small SIM-cards with 3V technology. For SIM card preparation you can use cell phone or external GSM modem. Set phone numbers from which management (module settings, add/delete SMS phone book) is authorized 1 A1 <Phone number1> 1) 2 A2 <Phone number2> 1) 1): full phone number with country code (see Note below) Example: enable 2 phone numbers for module management 1 A A Example: enable all phone numbers (disable authorization numbers; all cell phone enabled for gate open) 1 A A2 <Phone number2> NOTE: For difference mobile operators can be difference number format in CLIP. For example for Latvia BITE and LMT TELE (without country code) Also for difference country can be difference number format in CLIP for UK: At position 001 and 002 you should write number with country code ( ) At position you should write number without country code ( )

9 in SIM and EEPROM stored in SIM and in EEPROM BR160GM-GATE module. After restart module from SIM card copy to EEPROM. After SMS command ADDNUM number added to in EEPROM and in SIM card. After SMS command DELNUM number deleted from in EEPROM and from SIM. You can write numbers to SIM directly 001 A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> A249 <Phone number 2490> 250 A250 <Phone number 250> Number at location 001 and 002 Number at location 001 and privileg.number: from this cell phone you can send SMS command for setting and control. - numbers, enabled for gate open process. If at location 001 empty or short number, for example 001 or 99, then all cell phone enabled for gate open process. You can write numbers to SIM. with SMS command ADDNUM or deleted number from SIM with SMS command DELNUM You can add new number to phone book ADDNUM SMS command. - If phone book full, you receive answer SMS 'SIM Full' - If phone book not full, new number entered to first empty position in phone book you receive SMS 'NR added' (you receive also position in phone book) - If number exist in phone book, you receive SMS 'NR exist' (number exist in phone book at position 042) - If number not exist in phone book, you receive SMS 'NR added' (number added at position 250) You can delete new number from phone book DELNUM SMS command. - If number not exist in phone book, you receive answer SMS 'NR not exist' - If number exist in phone book, you receive answer SMS 'NR deleted' You can read number from phone book GETNUM SMS command. New SMS command Maxnn1 Maxnn9 Maxnn1 30 numbers maximum; Maxnn2 60 numbers maximum (default setting) Maxnn8 240 numbers maximum; Maxnn9 250 numbers maximum

10 Example: ADDNUM A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> A250 <Phone number 250> DELNUM A1 <Phone number 1> 002 A2 <Phone number 2> 003 A3 <Phone number 3> A250 <Phone number 250> Add number to SIM phone book ADDNUM or Addnum add number to SIM phone book - add number to SIM phone book Answer SMS: NR added - if number added to SIM phone book at location 012 NR exist - if number exist in SIM phone book at location 012 where: NR location in SIM phone book NOTE: For difference mobile operators can be difference number format in CLIP. For example for Latvia BITE and LMT TELE (without country code) Also for difference country can be difference number format in CLIP for UK: At position 001 and 002 you should write number with country code ( ) At position you should write number without country code ( )

11 Delete number from SIM phone book DELNUM or Delnum delete number from SIM phone book - delete number from SIM phone book Answer SMS: NR deleted - if number deleted from SIM phone book (from position 011) NR not exist - if number not exist in SIM phone book where: NR location in SIM phone book Read number from phone book GETNUM read number from SIM phone book with location 051 Answer SMS: NR 051: Note: - If in your cell phone in phone book phone number exist with name, for example, SMN your cell phone display following answer SMS: NR 11 SMN deleted NR 001: SMN NR 12 SMN added Set output impulse duration (accuracy +/- 20%) SETDD 12 SETDD 90 SETDD 00 SETDD 02 SETDD 00 - set duration = 12 sec - set duration = 90 sec - disable output impulse - latch mode - set pulse duration = 2 sec - disable pulse latch mode

12 Remote control You can with dialing (without connection) open your gate. Output 3 and Output 2 for gate control. We can turn on and turn off module outputs with SMS command: SETOU and RSTOU. SETOU1 RSTOU1 - set output 1 to '0' - active state. - reset output 1 to '1' - passive state. Answer SMS: INP=3F OUT=00 Pulse (sec) 5 where: INP=3F OUT=00 Pulse (sec) - input state in HEX (inverse to inputs on terminal block) - output state (output 4..1) in HEX - output impulse duration (in sec) If Pulse = 00 (see SMS command Setdd), then latch mode. First dial - turn on, second dial - turn off

13 SMS Control Command List Control Command List Command Function Return Message Description 1) Read Status Getst Get Status INP=3F OUT=00 Pulse (sec) 5 Input and output state, pulse duration (output 3) Outputs control Setou1 Set Output 1 - Set Output 1 Setou2 Set Output 2 - Set Output 2 Setou3 Set Output 3 - Set Output 3 - relay ON Rstou1 Reset Output 1 - Reset Output 1 Rstou2 Reset Output 2 - Reset Output 2 Rstou3 Reset Output 3 - Reset Output 3 - relay OFF Setdd NN Addnum Delnum Set output impulse duration Add new number Delete number Settings INP=3F OUT=00 Pulse (sec) 5 Settings NR added or NR exist NR deleted or NR not exist Getnum Read number NR 167: Set output impulse duration, NN = sec.; default 02 if NN=00, then latch mode ADDNUM DELNUM GETNUM location in SIM phone book Rstart Restart Restart (module work after 2 min) MaxnnN Set Max numbers note: This SMS command support only new version software INP=3F OUT=00 Pulse (sec) 5 MaxNN=60 N from 1 to 9 N=1 30 numbers N=2 60 numbers (default)... N=8 240 Numbers N=9 250 numbers Note: 1): Not case sensitive. You can use GETNUM, Getnum, SMS command module executed after 60 sec maximum. If you change first number in SIM phone book, required restart module for new installation.

14 SMS Reporting Message (Alarm SMS in SIM) SMS Message Number in SIM SMS Message Cell Phone Number Input NR 1 Event 1 <Phone number> 1 2 Event 2 <Phone number> 2 3 Event 3 <Phone number> 3 4 Event 4 <Phone number> 4 5 Event 5 <Phone number> 5 Example SMS Message Cell Phone Input Nr Text of Messages Number Number Connected to 1 Door open <Phone number> 1 Door sensor 2 Smoke detection <Phone number> 2 Smoke detectors 3 <Phone number> 3 4 <Phone number> 4 Not connected input state Input state Status data INP= Input state with connected pull-up resistor (J2) Input Input Input Input Input Input Active event on input Input state Input Input Input Input Input 5 1-0

15 Output state Output state Output state Status data OUT= Output 1 Open Drain 1 1 Output 2 Open Drain 1 1 Output 3 Relay NO 1 1 Output 4 Open Drain 1 1 Phone numbers from which management is authorized (optional) Delete all entry in active phone book and write 3 phone numbers of mobile phone. 1 A1 <Phone number1> 2 A2 <Phone number2> 3 A3 <Phone number3> Note 1: full phone number with country code Example - enable 2 phone numbers for module management (A1 and A2); for gate open enable only number in SIM phone book (max. 250 numbers) 1 A A A Example - enable all numbers (disable authorization numbers); all number enabled for gate open. 1 A A2 <Phone number2>

GSM Controller BR160SM-Sd BR161SM-Sd V1.2

GSM Controller BR160SM-Sd BR161SM-Sd V1.2 GSM Controller BR0SM-Sd BRSM-Sd V. Standard version for digital signal monitoring GSM module for SMS remote monitoring and control applications Alarm Notification Remote Control www.bieneelectronics.com

More information

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data Version for flow (pulses), analog and digital signal monitoring GSM module for SMS remote monitoring and control applications Features

More information

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A GSM Controller BR16SM-2SMT-4A-A / BR161SM-2SMT-4A-A Temperature, analog and digital version for green energy equipments. GSM module for SMS remote monitoring and control applications Features Internal

More information

GSM controller module for SMS remote monitoring, alarming and control applications BR900-ST. Preliminary data. GSM module BR900-ST.

GSM controller module for SMS remote monitoring, alarming and control applications BR900-ST. Preliminary data. GSM module BR900-ST. GSM controller module for SMS remote monitoring, alarming and control applications BR900ST Preliminary data Introduction The BR900ST controller is a low dimensions low cost GSM communications device that

More information

GSM/GPRS GPS Tracker for real-time GPS data tracking BR900-GPS

GSM/GPRS GPS Tracker for real-time GPS data tracking BR900-GPS GSM/GPRS GPS Tracker for realtime GPS data tracking BR9GPS Preliminary data oct. 8 www.bieneelectronics.com Features: Quad band GSM module SIM9 or compatible GPS receiver SIM8 Solid State Relay outputs

More information

Tu Sitio de Automatización!

Tu Sitio de Automatización! 1. Overview a. Introduction Tu Sitio de Automatización! LBSMS Basic-Q421 is integrated with a 16 bit MCU and reliable Siemens MC39i GSM module. b. Application Industrial equipment monitoring Data capturing

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

Hardware Interface Description

Hardware Interface Description Cellular GSM Engine Hardware Interface Description Feature Incorporates 700XR/A module Frequency bands Power supply Operating temperature Physical RoHS, WEEE Implementation The module handles all processing

More information

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs MobilTherm 2ad GSM temperature alarm module with auxiliay inputs and relay outputs The MobilTherm-2ad is a GSM temperature and remote signaling module, designed for GSM based remote control, remote signal.

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

Robustel GoRugged M1000 USB Quick Guide

Robustel GoRugged M1000 USB Quick Guide Robustel GoRugged M1000 USB Quick Guide Chapter 1. Interface Introduction 1.1 Overview 1.2 LED Indicators After inserting the SIM card into the modem and power on, the LED indicator s status should be

More information

Release Note. How to Use the OptoCon Connection Module. 1 Introduction. Option C Revision 4 Revised 8/13/98

Release Note. How to Use the OptoCon Connection Module. 1 Introduction. Option C Revision 4 Revised 8/13/98 33 South La Patera Lane Santa Barbara, CA 93117-3214 ph (805) 681-3300 fax (805) 681-3311 tech@motioneng.com www.motioneng.com Release Note How to Use the OptoCon Connection Module Option C002-0007 Revision

More information

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs MobilSwitch-5c Multi channel GSM signaling and remote control unit with analog, digital, counter inputs The MobilSwitch-5c GSM device is developed for industrial signaling and remote controlling purposes.

More information

ELC2212X user manual

ELC2212X user manual user manual 1 Safety: Please, keep safety precautions as follows: Do not use our device nearby the medical aparatures. Do not use our device nearby explosive atmosphere. Do not put to high moisture, chemicals

More information

GSM Voice Active Monitoring OTP-GSM89

GSM Voice Active Monitoring OTP-GSM89 GSM Voice Active Monitoring OTP-GSM89 1 Feature: 1. Voice active monitoring, when detect voice level higher then voice setting sensitivity, the module will send SMS and making call automatically. 2. Can

More information

ACORN User Guide For Revision (Aka Acorn_rev3) Updated 1/23/17

ACORN User Guide For Revision (Aka Acorn_rev3) Updated 1/23/17 ACORN User Guide For Revision 171025 (Aka Acorn_rev3) Updated 1/23/17 Overview ACORN is technically a breakout board for the BeagleBone Green or BeagleBone Black embedded computer. The remainder of this

More information

Pmod modules are powered by the host via the interface s power and ground pins.

Pmod modules are powered by the host via the interface s power and ground pins. 1300 Henley Court Pullman, WA 99163 509.334.6306 www.store. digilent.com Digilent Pmod Interface Specification 1.2.0 Revised October 5, 2017 1 Introduction The Digilent Pmod interface is used to connect

More information

BB-303 Manual Baseboard for TMCM-303

BB-303 Manual Baseboard for TMCM-303 BB-303 Manual Baseboard for TMCM-303 Trinamic Motion Control GmbH & Co. KG Sternstraße 67 D 20357 Hamburg, Germany http://www.trinamic.com BB-303 Manual (V1.04 / Jul 9th, 2007) 2 Contents 1 Features...

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

Module Technical characteristics

Module Technical characteristics Module Technical characteristics Power supply 220VAC Average power consomption 0.1W Peak power consumption 25W Battery 1400mAh :(charge average about 3 days ) 4 Input opto-isolated 220AC o 12VDC 4 separated

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

Pridgen Vermeer Robotics Xmega128 Manual

Pridgen Vermeer Robotics Xmega128 Manual Features: 12x PWM signals with 5V supply 8x A/D Inputs with 3.3V supply 2x RS 232 Terminals 1x SPI Interface 4x 8-bit Digital IO ports 3.3V Power Bus LCD Header (4-bit mode) Smart Power Connecter Power

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS... 2 DESCRIPTION... 3 LIST OF COMPATIBLE CONTROL PANELS...

More information

DinBox M36 Hardware Description Guide

DinBox M36 Hardware Description Guide DinBox M36 Hardware Description Guide This manual covers the different hardware settings when using the DinBox M36 equipment. Next to this you will find all the relevant technical information needed when

More information

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

RN-174. WiFly GSX Super Module. Features. Description. Applications.   rn-174-ds v1.1 1/24/2011 www.rovingnetworks.com rn-174-ds v1.1 1/24/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation -V/AB & ABK V.5 (2 ) Important Notes: ) Before you install this equipment, please read this full manual. Installation Manual Wiring 8) Carefully follow the wiring instructions. 2) Before fully installing

More information

GSM SECURITY AND CONTROL SYSTEM ESIM021

GSM SECURITY AND CONTROL SYSTEM ESIM021 GSM SECURITY AND CONTROL SYSTEM ESIM021 Manual v1.1 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Alarm and control system

More information

Technical Documentation, RTCU-SA

Technical Documentation, RTCU-SA Technical Documentation, RTCUSA The RTCUSA product (GSM antenna not included in product) The RTCUSA product is a RTCU unit with a builtin communications module such as GSM, DECT or FSK Modem. The RTCUSA

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany. MODULES FOR BLDC MOTORS MODULES Hardware Version V 1.10 HARDWARE MANUAL + + TMCM-1613 + + Single Axis BLDC Controller / Driver Block-commutation Hall-sensor based Analog+digital inputs / outputs Up-to

More information

C10- PARALLEL PORT INTERFACE CARD Rev. 8

C10- PARALLEL PORT INTERFACE CARD Rev. 8 C10- PARALLEL PORT INTERFACE CARD Rev. 8 User manual Rev. 1 1. Overview This card provides an easy way of interfacing your inputs and outputs from you parallel port. It provides terminals for the connections

More information

T100MD PLC Installation Guide

T100MD PLC Installation Guide T100MD-2424+ PLC Installation Guide LCD Display Module MCR 12 to 24V DC Power Supply for PLC Master Control Relay for Output. + - EEPROM Write-Protection when J2 at WP 14-pin LCD Display Port Two-wire

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

A TECHNICAL INFO A. External GSM AT420 DATE :

A TECHNICAL INFO A. External GSM AT420 DATE : DATE :02-02-04 A TECHNICAL INFO A External GSM AT420 The external GSM AT420 is a GSM data modem. It allows a communication with the A when a cabled telephone connection is impossible. This modem can be

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers MobilGate - 128d Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers MobilGate-128d is an industrial GSM module developed for remotely controlling doors, garage doors

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

Manual for firmware 1.15 and subsequent

Manual for firmware 1.15 and subsequent GSM Controller v3.0 Manual for firmware 1.15 and subsequent GSM Controller GSM v3 controller allow monitor by gsm network different phisical parameters and control remotely on/off 5 outputs. Control is

More information

Two-wire. Jumper for 12V. J2 Enable Adjust D/A1. Super PLC Warning: Warranty Void if this label is damaged 62256LP-12 CMOS RAM 4.

Two-wire. Jumper for 12V. J2 Enable Adjust D/A1. Super PLC Warning: Warranty Void if this label is damaged 62256LP-12 CMOS RAM 4. T100MD-888+ PLC Installation Guide LCD Display Module 1N4007 (optional) + - 12 to 24V DC Power Supply for PLC Contrast Adjust 14-pin LCD Display port Two-wire RS485 + - Jumper for 12V 1000µ F 5 E.Cap (Optional)

More information

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Previous Configuration: BY240 Synchronous Controller Option: Parallel interface PS240 and BCD thumbwheel switch set BY106-5

More information

ADDJOG User Guide 7/30/10. Overview

ADDJOG User Guide 7/30/10. Overview ADDJOG User Guide 7/30/10 Overview The ADDJOG is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The ADDJOG has 64 open collector outputs and 64 non-isolated inputs.

More information

GPRS Pager 3 INSTALATION AND USER MANUAL

GPRS Pager 3 INSTALATION AND USER MANUAL GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation

More information

USB-4303 Specifications

USB-4303 Specifications Specifications Document Revision 1.0, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.

More information

Pridgen Vermeer Robotics ATmega128 Revision 0

Pridgen Vermeer Robotics ATmega128 Revision 0 Features: 6x 8-bit I/O Ports 4x A/D Inputs 6x PWM Headers 2x RS 232 Terminals Power Bus LCD Header (4-bit mode) Smart Power Connecter Power Switch Header Power LED Debug LED Note: Some pins have multiple

More information

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK-1201 Assembled by : Engineer: Installation date : Phone number elevator : PIN : PUK: Battery changed on date : Name : Keep this manual on a save place,

More information

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module ARDUINO BASED GSM/SMS Remote Control Unit USING SIM800 GSM Module Designed by ERIC BROUWER April 2017 Contents Introduction... 4 SIM Card requirements... 5 SIM Card Installation... 5 Electrical Connections...

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

Revision History. Version Date Changes Error in PIN description SPI jack Initial version

Revision History. Version Date Changes Error in PIN description SPI jack Initial version MANUAL ANAGATE SPI ANALYTICA GmbH Vorholzstrasse 36 Tel. +49 721 35043-0 E-mail: info@analytica-gmbh.de D-76137 Karlsruhe Fax: +49 721 35043-20 WWW: http://www.analytica-gmbh.de 1 2004-2006, Analytica

More information

IPM650 Intelligent Panel-Mount Display

IPM650 Intelligent Panel-Mount Display Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

I2C-IN830M, I2C-IN830MA 8-Input Optocouplers I2C-bus, DIN rail supports

I2C-IN830M, I2C-IN830MA 8-Input Optocouplers I2C-bus, DIN rail supports I2C-IN83M, I2C-IN83MA 8-Input Optocouplers I2C-bus, DIN rail supports Features PCF8574 and PCF8574A I2C chips upport khz I2C bus frequency On-board I2C bus pull-up resistors Address by 3 jumpers for use

More information

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION The Solution Multi-Input Module INSTALLATION INSTRUCTIONS Model: MIM-62 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION MIM-62 connects up to 6 monitored entrapment protection

More information

GSM communicator GD-06 Allegro Complete manual

GSM communicator GD-06 Allegro Complete manual GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or

More information

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module ARDUINO BASED GSM/SMS Remote Control Unit USING SIM800 GSM Module Designed by ERIC BROUWER April 2017 Contents Introduction... 4 SIM Card requirements... 5 SIM Card Installation... 5 Electrical Connections...

More information

Communi-Cell Communicator Nokia Version

Communi-Cell Communicator Nokia Version Communi-Cell Communicator Nokia Version Jan 2007 Instruction Manual 1 ABOUT THE COMMUNI-CELL COMMUNICATOR SYSTEM The Communi-Cell Communicator system is based on GSM SMS technology. It uses a standard

More information

UCBB dual port breakout board user's manual

UCBB dual port breakout board user's manual UCBB dual port breakout board user's manual 1/14 Contents 1 Features 2 Dimensions 3 Connectors 3.1 Screw terminals 3.2 IDC ports 3.3 Powering 3.4 Outputs 3.5 Inputs 4 LED indicators 5 Example connections

More information

RN-174 WiFly Super Module

RN-174 WiFly Super Module RN- WiFly Super Module Features Evaluation board for the RN- module Supports chip antenna (RN--C), PCB trace antenna (RN--P), wire antenna (RN--W), and U.FL connector for an external antenna (RN--U) Ultra-low

More information

UP100-GSM. GSM based intercom and access control. Installation and user manual

UP100-GSM. GSM based intercom and access control. Installation and user manual UP100-GSM GSM based intercom and access control Installation and user manual UP100-GSM REV.1.4 20/01/2014 Table of contents 1 Functions...3 2 Features...3 3 Application area...3 4 Operation...3 4.1 Visitor

More information

GSM communicator G17F INSTALLATION MANUAL

GSM communicator G17F INSTALLATION MANUAL INSTALLATION MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS...3 DESCRIPTION...4 SPECIFICATIONS...4 COMMUNICATOR

More information

Special-Purpose Photoelectric Sensors

Special-Purpose Photoelectric Sensors Special-Purpose Photoelectric Sensors Miniature Sensors with Separate Amplifiers Fit Tight Spaces Fast, 1 ms response time Light incident indicator on sensor Dust-resistant flat lens surface New, thin

More information

Hardware Installation

Hardware Installation LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate

More information

PLCADD1616 User Guide 3/29/10. Overview

PLCADD1616 User Guide 3/29/10. Overview PLCADD1616 User Guide 3/29/10 Overview The PLCADD1616 is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The PLCADD1616 has 16 relay outputs and 16 optically isolated

More information

MANUAL 3G GATE OPENER

MANUAL 3G GATE OPENER ARISTEL NETWORKS MANUAL 3G GATE OPENER AN1706 (WCDMA) ` Please read these instructions completely before use it 3G/GSM Gate Opener 1/18 Rev. V1.4B, Jan 2019 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...3

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information

SimPLC. User Manual.

SimPLC. User Manual. SimPLC User Manual www.dizzy.co.za Contents Introduction... 4 Overview Top... 5 Power Circuitry... 6 Microcontroller... 7 Real-Time Calendar and Clock (RTCC)... 7 Reset Button... 7 Oscillator Socket...

More information

ONYX-MM-XT PC/104 Format Counter/Timer & Digital I/O Module

ONYX-MM-XT PC/104 Format Counter/Timer & Digital I/O Module ONYX-MM-XT PC/104 Format Counter/Timer & Digital I/O Module User Manual V1.4 Copyright 2009 Diamond Systems Corporation 1255 Terra Bella Avenue Mountain View, CA 94043 USA Tel (650) 810-2500 Fax (650)

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

DIGITAL COMPASS SOLUTION

DIGITAL COMPASS SOLUTION Features 5 Heading Accuracy, 0.5 Resolution 2-axis Capability Small Size (19mm x 19mm x 4.5mm), Light Weight Advanced Hard Iron Calibration Routine for Stray Fields and Ferrous Objects 0 to 70 C Operating

More information

H3-EM Electronic Swinghandle Operating Instructions

H3-EM Electronic Swinghandle Operating Instructions H3-EM-66-100 Electronic Swinghandle Operating Instructions Package Contents H3-EM-66-x00 Electronic Swinghandle with RFID Reader (qty1) EM-0-45827 M3x25 POZIDRIV Mounting Screws (qty 4) EM-0-47151 M3x14

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

ZSSC4151 Evaluation Kit Hardware Manual

ZSSC4151 Evaluation Kit Hardware Manual Important Notes Restrictions in Use IDT s ZSSC4151 SSC Evaluation Kit, consisting of the SSC Communication Board (SSC CB), ZSSC415x/6x/7x Evaluation Board (SSC EB), Sensor Replacement Board (SSC RB), and

More information

DMX-K-DRV Integrated Step Motor Driver Manual

DMX-K-DRV Integrated Step Motor Driver Manual Tu Sitio de Automatización! DMX-K-DRV Integrated Step Motor Driver Manual Table of Contents 1. Introduction... 4 2. Part Numbering Scheme... 4 3. Dimensions... 5 NEMA 11 DMX-K-DRV... 5 NEMA 17 DMX-K-DRV...

More information

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above EZY SWITCH SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above Table of Contents Outputs 5 Inputs 6 COMMANDS Getting Started Setting Up Initial User 8 Adding a User 9

More information

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 0, 50 GHz Product Overview High performance transfer switches for microwave and RF instrumentation and systems Exceptional repeatability for more

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

WICE-SPI Hardware Operation Manual

WICE-SPI Hardware Operation Manual WICE-SPI Hardware Operation Manual 1. Hardware Instruction 1. WICE-SPI processes data transmission, programming or emulation through USB 2.0 interface and does not need external power. 2. WICE-SPI is equipped

More information

RN-171-XV b/g Wireless LAN Module

RN-171-XV b/g Wireless LAN Module RN-171-XV 802.11 b/g Wireless LAN Module Features Drop-in Wi-Fi solution for existing systems that currently use 802.15.4 modules Based on Roving Networks robust RN-171 Wi-Fi module Based on a pseudo-standard

More information

Mega128-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

Mega128-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX Mega128-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN 46268 (317) 471-1577 (317) 471-1580 FAX http://www.prllc.com GENERAL The Mega128-Development board is designed for

More information

EXL x240 Graphic LCD Smart Module 3,8 SHORT FORM TECHNICAL SPECIFICATIONS. Via di Corticella, Bologna, Italy

EXL x240 Graphic LCD Smart Module 3,8 SHORT FORM TECHNICAL SPECIFICATIONS.   Via di Corticella, Bologna, Italy 320x240 Graphic LCD Smart Module 3,8 SHORT FORM TECHNICAL SPECIFICATIONS www.exelmicroel.it Via di Corticella, 201 40128 - Bologna, Italy Tel: +39 051 6380211 Fax: +39 051 6380226 exelbo@exelmicroel.it

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

02/11/2015

02/11/2015 48 x 48 Max. Counting Speed 5 KHZ Green backlit LCD display Part number 87629111 Counter, Preselection chronometer Maximum input frequency 5 k Hz Simple parameter setting, configuration using text menus

More information

HopperOne S11 Std Pulse

HopperOne S11 Std Pulse HopperOne S11 Std Pulse Operator s manual Rev. 1.02 HopperOne S11 Std Pulse Standard / Reverse Operator s Manual 1. General description Congratulations for your purchase of the Alberici HopperOne S11!

More information

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output Mobil Switch-Nano Industrial grade GSM signalling and remote control module with common input and relay output The MobilSwitch-Nano module is a general, industrial-grade GSM module, developed for remote

More information

HI SEC Integrated Systems

HI SEC Integrated Systems Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

MINI DSP EVM KIT Application Manual

MINI DSP EVM KIT Application Manual MINI DSP EVM KIT Application Manual Table of contents 1. System overview... 3 2. Features... 3 3. MINI DSP module connections and controls... 4 3.1. External device connections... 5 3.1.1. For GPIO output

More information

Quad-Relay Delay Switch (QRDS) User Manual (v1.0)

Quad-Relay Delay Switch (QRDS) User Manual (v1.0) Quad-Relay Delay Switch (QRDS) User Manual (v1.0) Introduction: The QRDS-1000 Quad-Relay Delay Switch provides general purpose control for up to four independent devices. It also offers optional activation

More information

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016 M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. THE DEVICE DEVICE FUNCTIONS TECHNICAL CHARACTERISTICS VISUAL APPEARANCE 03. INSTALLATION

More information

MultiConnect OCG. Break-Out Board. Developer s Guide

MultiConnect OCG. Break-Out Board. Developer s Guide MultiConnect OCG Break-Out Board Developer s Guide Copyright and Technical Support MultiConnect OCG Break-Out Board Developer s Guide Models: MTOCG-BOB S000518A, Version A Copyright This publication may

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS CRD _ MINI LOG READOUT UNITS AND DATALOGGERS MINI _EN_06_06/2016 mini log Mini log is a four-channel logger that can be factory-configured to read specific types of sensors: it reads analog (current, voltage,

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

Slick Line Acquisition System Manual

Slick Line Acquisition System Manual SCIENTIFIC DATA SYSTEMS, INC. SLICK LINE ACQUISITION BOX Slick Line Acquisition System Manual This document contains proprietary information. Copyright 2005 Scientific Data Systems, Inc. All rights reserved.

More information

4 Channel GSM Controller Installer Manual

4 Channel GSM Controller Installer Manual ! WARNING! Only fully Qualified Personnel should install or service this Device. 4 Channel GSM Controller Installer Manual 4 Channel Controller 2T-Technology www.2t-tec.com SN: 01001 Device Telephone Number:

More information

GSM/GPS/GPRS Vehicle/Motorcycle Motorbikes Tracking. User Manual V7.0

GSM/GPS/GPRS Vehicle/Motorcycle Motorbikes Tracking. User Manual V7.0 GSM/GPS/GPRS Vehicle/Motorcycle Motorbikes Tracking User Manual V7.0 Introduction Notes (ASICO INDUSTRIAL) 2005 Every effort has been made to ensure that the contents of this booklet are correct. However,

More information

SBD WARRIOR DATA SHEET

SBD WARRIOR DATA SHEET SBD WARRIOR DATA SHEET www.satelligent.ca v1.3 Features Controller for Iridium 9603 SBD transceiver 48 channel SiRFstarIV chipset based GPS Serial interface for 3rd party equipment or PC control Wide supply

More information