HPE Moonshot System Configuration and Compatibility Guide

Size: px
Start display at page:

Download "HPE Moonshot System Configuration and Compatibility Guide"

Transcription

1 HPE Moonshot System Configuration and Compatibility Guide Abstract This guide describes HPE Moonshot System hardware configuration options and hardware and software compatibility rules. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. Part Number: Published: July 2017 Edition: 12

2 Copyright 2016, 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or copying. Consistent with FAR and , Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise website. Acknowledgments Intel, Itanium, Pentium, Intel Inside, and the Intel Inside logo are trademarks of Intel Corporation in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries. AMD is a trademark of Advanced Micro Devices, Inc. ARM is a trademark of ARM Limited.

3 Contents Introduction... 6 HPE Moonshot System overview...6 HPE Moonshot System components... 7 HPE Moonshot 1500 Chassis... 7 Cartridge slot and switch module bay identification... 7 Cartridges...8 HPE ProLiant m300 Server Cartridge... 8 HPE ProLiant m350 Server Cartridge... 9 HPE ProLiant m400 Server Cartridge HPE ProLiant m510 Server Cartridge HPE ProLiant m700 Server Cartridge HPE ProLiant m700p Server Cartridge HPE ProLiant m710 Server Cartridge HPE ProLiant m710p Server Cartridge HPE ProLiant m710x Server Cartridge HPE ProLiant m800 Server Cartridge Switch modules and uplink modules...18 HPE Moonshot-45G Switch Module...18 HPE Moonshot-180G Switch Module...19 HPE Moonshot-45Gc Switch Module...20 HPE Moonshot-45XGc Switch Module HPE Moonshot-180XGc Switch Module HPE Moonshot-6SFP Uplink Module HPE Moonshot-4QSFP+ Uplink Module HPE Moonshot-16SFP+ Uplink Module...23 Power supplies...24 HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply...24 HPE 1500W Common Slot 48V DC Input Hot-Plug Power Supply...24 HPE 1500W Common Slot Platinum Plus Hot Plug Power Supply...25 HPE Moonshot 1500 Chassis Management Module HPE Moonshot Remote Console Administrator...25 Drivers, firmware, and software updates...26 Fans Cables...27 Software tools and solutions Product QuickSpecs HPE Moonshot ilo Chassis Management Firmware HPE Moonshot ilo CM Integrated Management Log...28 HPE Moonshot ilo CM Event Log...28 HPE Insight Cluster Management Utility...28 HPE Moonshot Component Pack Smart Update Manager...29 Configuration rules Contents 3

4 Basic configuration rules...30 Supported cartridge configurations Chassis population rules Cartridge population rules...31 m510-16c cartridge population rules...31 Like cartridge configuration population rules Sample like cartridge configuration Mix-match cartridge configuration population rules Sample mix-match cartridge configuration...33 mrca population rules mrca recommended population rules mrca detailed population rules...35 Switch module and uplink module population rules Power supply population rules Fan population rules Hardware compatibility...40 Hardware compatibility matrix...40 Software compatibility...43 Software compatibility matrix Device mapping...44 Cartridge mapping Warranty and regulatory information...45 Warranty information...45 Regulatory information...45 Belarus Kazakhstan Russia marking Turkey RoHS material content declaration...46 Ukraine RoHS material content declaration Electrostatic discharge...48 Preventing electrostatic discharge Grounding methods to prevent electrostatic discharge...48 Websites Support and other resources...50 Accessing Hewlett Packard Enterprise Support Accessing updates...50 Remote support Acronyms and abbreviations Contents

5 Documentation feedback Contents 5

6 Introduction HPE Moonshot System overview The HPE Moonshot System enables a new class of servers engineered to address the IT challenges created by social, cloud, mobile, and big data. HPE Moonshot cartridges are built from chips more commonly found in smart phones and tablets, which allow the servers to deliver reduced energy use and a high-density footprint, all at a significantly lower cost. The Moonshot System is built using the following system components: Chassis Cartridges Switch modules and uplink modules HPE Moonshot 1500 Chassis Management module Fans Power supplies As described in this document, configurations vary depending on the cartridges installed. 6 Introduction

7 HPE Moonshot System components HPE Moonshot 1500 Chassis The HPE Moonshot 1500 Chassis is a 4.3U, rack mounted chassis. The chassis supports the following devices. Component Minimum Maximum Cartridges 1 45 Switch module and uplink module pairs HPE Moonshot 1500 Chassis Management module Power supplies Fans Dependent on the configuration The Moonshot 1500 CM module identifies the installed cartridge model and switch module model information. The system backplane on the bottom of the chassis routes communications from the cartridges between the internal switch modules and the cartridges, which is connected to the external network through the uplink modules. For more information about these mappings, see Device mapping on page 44. Cartridge slot and switch module bay identification The chassis provides 45 cartridge slots (1-45) and two switch module bays (A-B). HPE Moonshot System components 7

8 Cartridges HPE ProLiant m300 Server Cartridge The HPE ProLiant m300 Server Cartridge is a single-node cartridge supported in any of the 45 cartridge slots in the chassis. 8 Cartridges

9 Item Description Processor One 2.4-GHz Intel Atom processor, 8 cores, 20 W, non-removable Memory Network Storage Four 1600MHz DIMM, DDR3 UDIMM SO-DIMM ECC (8GB) Integrated NIC: 1 dual-port 1GbE NIC per processor SFF drive: 500 GB SATA 1 TB SATA 240 GB SSD Boot Direct from drive Network Power < 34 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m350 Server Cartridge The HPE ProLiant m350 Server Cartridge is a four-node cartridge supported in any of the 45 cartridge slots in the chassis. HPE ProLiant m350 Server Cartridge 9

10 Item Processor Memory Network Storage Description Four 1.7-GHz Intel Atom, 8 cores, 13 W, nonremovable Four 1600 MHz DIMM, DDR3 UDIMM SO-DIMM ECC (8GB) Integrated NIC: 1 dual-port 2.5GbE NIC per processor One solid state device per processor: 32 GB 64 GB Boot Direct from solid state device Network Power < 60 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m400 Server Cartridge The HPE ProLiant m400 Server Cartridge is a single-node cartridge supported in any of the 45 cartridge slots in the chassis. 10 HPE ProLiant m400 Server Cartridge

11 Item Processor Memory Network Storage Description One 2.4-GHz ARM, 64-bit, non-removable Eight 1600 MHz DIMM, DDR3 UDIMM SO-DIMM ECC (8GB) Integrated NIC: 1 dual-port 10GbE NIC One solid state device: 120 GB 240 GB 480 GB Boot Direct from solid state device Network Power < 65 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m510 Server Cartridge The HPE ProLiant m510 Server Cartridge is a single-node cartridge supported by any of the 45 cartridge slots in the chassis. For population rules for the 16 core m510 cartridge, see m510-16c cartridge population rules on page 31. HPE ProLiant m510 Server Cartridge 11

12 Item Processor Memory Network Storage Description Intel Xeon D "Broadwell-DE" D-1548: 8 cores, 45W, 2.0GHz base/2.3ghz allcore turbo, non-removable D-1587: 16 cores, 65W, 1.7GHz base/2.1ghz all-core turbo, non-removable Four RDIMM slots available. Maximum capacity 128GB DDR4 ECC 2133/2400 Options: HPE Memory (8GB, 16GB, 32GB) Integrated NIC: 1 Mellanox ConnectX - 3 PRO Dual Port 10GbE (RoCE) 3 Local m.2 modules (>1TB max.): One SATA Options: 64GB, 120G, 240G Two PCIe 2280/ Options: 256G, 512G, and 1TB Via external storage (iscsi with iser acceleration) Boot Network (PXE and iscsi) Local Boot via SATA/PCIe attached M.2 (NGFF) module Power m510: ~81W per cartridge m510-16c: ~91W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( 12 HPE Moonshot System components

13 HPE ProLiant m700 Server Cartridge The HPE ProLiant m700 Server Cartridge is a four-node cartridge supported in any of the 45 cartridge slots in the chassis. Item Processor Memory Network Storage Graphics Description Four 1.5-GHz AMD APU, 4 cores, 15 W, nonremovable Four 1600 MHz DIMM, DDR3 UDIMM SO-DIMM ECC (8GB) Onboard NIC: 1 dual-port 1GbE NIC per processor One issd per processor: 32 GB 64 GB Internal AMD GPU Core Boot Direct from drive Network Power < 80 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m700p Server Cartridge The HPE ProLiant m700p Server Cartridge is a four-node cartridge supported by any of the 45 cartridge slots in the chassis. HPE ProLiant m700 Server Cartridge 13

14 Item Processor Memory Network Description Four AMD Opteron X2170 APUs, 2.4GHz, 4 cores, 25W, 2MB L2 Cache with AMD Radeon R5E GPU, non-removable Four SODIMMs total One SODIMM per processor, 8GB or 16GB, each up to 1600MHz DDR3 PC SDRAM with ECC Broadcom BCM5720 Ethernet Controller, Dual-port 1GbE NIC Storage M.2 4x64GB SSD Mezzanine Kit (1x64GB per processor) M.2 4x120GB SSD Mezzanine Kit (1x120GB per processor) M.2 4x240GB SSD Mezzanine Kit (1x240GB per processor) Boot Direct from solid state device Network Power Typical: 65W, Max: 93W For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m710 Server Cartridge The HPE ProLiant m710 Server Cartridge is a one-node cartridge supported in any of the 45 cartridge slots in the chassis. 14 HPE ProLiant m710 Server Cartridge

15 Item Processor Memory Network Storage Description One 1.8-GHz Intel Xeon, 4 cores, 47 W, nonremovable Four 1600 MHz DIMM, DDR3 LVDIMM SO-DIMM (8GB) Integrated NIC: 1 dual-port 10GbE NIC One solid state device: 120 GB 240 GB 480 GB Boot Direct from solid state device Network Power < 70 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m710p Server Cartridge The HPE ProLiant m710p Server Cartridge is a one-node cartridge supported in any of the 45 cartridge slots in the chassis. HPE ProLiant m710p Server Cartridge 15

16 Item Processor Memory Network Storage Description One 2.9-GHz Intel Zeon, 4 cores, 47 W, nonremovable Four 1600 MHz DIMM, DDR3 LVDIMM SO-DIMM (8GB) Integrated NIC: 1 dual-port 10GbE NIC One solid state device: 120 GB 240 GB 480 GB Boot Direct from solid state device Network Power < 80 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE ProLiant m710x Server Cartridge The HPE ProLiant m710x Server Cartridge is a single-node cartridge supported by any of the 45 cartridge slots in the chassis. 16 HPE ProLiant m710x Server Cartridge

17 Item Description Processor Intel Skylake Xeon E3 SoC, 4 cores with Hyperthreading, 3.0GHz base/3.4ghz all core turbo Intel Iris Pro P580 Integrated Graphics with 72 Execution Units and 128MB edram, 45W TDP, non-removable Memory Network Storage Four 2133 MHz DIMM, DDR4 ECC SODIMM (8 or 16GB) Integrated NIC: Mellanox Connect X-3 PRO 2 Port 10G One SATA 2242 m.2: 64 GB 120 GB 240 GB Four NVMe 2280 m.2, or two 2280 and two m.2: 256 GB 512 GB 1024 GB Boot Direct from solid state device Network Cartridge I/O panel using Front I/O panel cable kit Power < 90 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( HPE Moonshot System components 17

18 HPE ProLiant m800 Server Cartridge The HPE ProLiant m800 Server Cartridge is a four-node cartridge supported in any of the 45 cartridge slots in the chassis. Item Processor Memory Network Storage Boot Power Description Four 1.0-GHz ARM processors, 8 DSP cores per node, non-removable Four 1600 MHz DIMM, DDR3 UDIMM SO-DIMM ECC (8GB) Onboard NIC: 1 dual-port 1GbE NIC per processor Solid state device: 32 GB 64 GB Direct from solid state drive <85 W per cartridge For information about operating systems supported by the Moonshot System, see the operating system support matrices ( Switch modules and uplink modules HPE Moonshot-45G Switch Module The HPE Moonshot-45G Switch Module enables Ethernet interconnect between the cartridges and is connected to the outside network through a paired Moonshot-6SFP Uplink Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. 18 HPE ProLiant m800 Server Cartridge

19 The switch module has the following key features: High density, low power Low latency switching performance 45 1GbE downlink ports per switch module 6 10GbE uplink ports per switch module Dual switch modules provide traffic isolation or can be stacked for resiliency. Rack level stacking to simplify management domain Configuration and management, with two tools: HPE Moonshot ilo Chassis Management Firmware HPE Moonshot-45G Switch Module CLI Layer 2, Layer 3 routing, and QoS Management (CLI, SNMP, SFLOW) No license keys required HPE Moonshot-180G Switch Module The HPE Moonshot-180G Switch Module enables Ethernet interconnect between the cartridges and is connected to the outside network through either a paired Moonshot-4QSFP+ Uplink Module or Moonshot-16SFP+ Uplink Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. HPE Moonshot-180G Switch Module 19

20 The switch module has the following key features: High density, low power Low latency switching performance 180 1GbE downlink ports per switch module Four 40GbE uplink ports or sixteen 10GbE uplink ports per switch module Dual switch modules, which provide traffic isolation or can be stacked for resiliency Configuration and management, with two tools: HPE Moonshot ilo Chassis Management Firmware HPE Moonshot-180G Switch Module CLI Layer 2, Layer 3 routing, and QoS Management (CLI, SNMP, SFLOW) No license keys required HPE Moonshot-45Gc Switch Module The HPE Moonshot-45Gc Switch Module enables Ethernet interconnect between the cartridges and is connected to the outside network through a paired Moonshot-6SFP+ Uplink Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. 20 HPE Moonshot-45Gc Switch Module

21 The switch module has the following key features: High density, low power Low latency switching performance 45 1GbE downlink ports per switch module 6 10GbE uplink ports per switch module Dual switch modules provide traffic isolation or can be stacked for resiliency. Rack level stacking to simplify management domain Configuration and management, with two tools: HPE Moonshot ilo Chassis Management Firmware HPE Moonshot-45Gc Switch Module CLI Layer 2, Layer 3 routing, and QoS Management (CLI, SNMP, SFLOW) No license keys required HPE Moonshot-45XGc Switch Module The HPE Moonshot-45XGc Switch Module enables Ethernet interconnect between the cartridges and is connected to the outside network through a paired Moonshot-4QSFP+ Uplink Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. The switch module has the following key features: High density, low power Low latency switching performance 45 10GbE downlink ports per switch module Four 40GbE uplink ports per switch module Dual switch modules, which provide traffic isolation or can be stacked for resiliency Configuration and management, with two tools: HPE Moonshot ilo Chassis Management Firmware HPE Moonshot-45XGc Switch Module CLI Layer 2, Layer 3 routing, and QoS Management (CLI, SNMP, SFLOW) No license keys required HPE Moonshot-45XGc Switch Module 21

22 HPE Moonshot-180XGc Switch Module The HPE Moonshot-180XGc Switch Module enables Ethernet interconnect between the cartridges and is connected to the outside network through a paired Moonshot-16SFP+ Uplink Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. The switch module has the following key features: High density, low power Low latency switching performance 180 1GbE downlink ports per switch module or 45 10GbE downlink ports Four 40GbE uplink ports or sixteen 10GbE uplink ports per switch module Dual switch modules, which provide traffic isolation or can be stacked for resiliency Configuration and management, with two tools: HPE Moonshot ilo Chassis Management Firmware HPE Moonshot-180G Switch Module CLI Layer 2, Layer 3 routing, and QoS Management (CLI, SNMP, SFLOW) No license keys required HPE Moonshot-6SFP Uplink Module The HPE Moonshot-6SFP Uplink Module provides external network connectivity to the Moonshot-45G Switch Module or the Moonshot-45Gc Switch Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. 22 HPE Moonshot-180XGc Switch Module

23 The uplink module has the following key features: SFP+ ports support either 10Gb or 1Gb depending on the pluggable module installed. Serial port for out-of-band management Link connectivity and activity LEDs UID LED/button for serviceability Reset button HPE Moonshot-4QSFP+ Uplink Module The HPE Moonshot-4QSFP+ Uplink Module provides external network connectivity to the Moonshot-180G Switch Module, the Moonshot-45GXc Switch Module, or the Moonshot-180XGc Switch Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. The uplink module has the following key features: QSFP+ ports support either 40Gb or 10Gb depending on module installed Serial port for out-of-band management Link connectivity and activity LEDs UID LED/button for serviceability Reset button HPE Moonshot-16SFP+ Uplink Module The HPE Moonshot-16SFP+ Uplink Module provides external network connectivity to the Moonshot-180G Switch Module, the Moonshot-45XGc Switch Module, or the Moonshot-180XGc Switch Module. The uplink module is installed in the rear of the chassis, and the switch module is installed inside the chassis. The uplink module has the following key features: SFP+ ports support either 10Gb or 1Gb depending on pluggable module installed Serial port for out-of-band management Link connectivity and activity LEDs HPE Moonshot-4QSFP+ Uplink Module 23

24 UID LED/button for serviceability Reset button Power supplies HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply The HPE 1200W Common Slot Platinum Plus Hot Plug Power Supply is supported on the ProLiant Moonshot Server. Depending on the cartridges and switches installed, two to four power supplies are required to power the chassis. For more information, see Power supply population rules on page 39. The 1200W Common Slot Platinum Plus Hot Plug Power Supply supports the following: Common slot design Power management for redundant power configurations HPE 1500W Common Slot 48V DC Input Hot-Plug Power Supply The HPE 1500W Common Slot 48V DC Input Hot-Plug Power Supply is supported on the ProLiant Moonshot Server. The 1500W Common Slot 48V DC Input Hot-Plug Power Supply supports the following: Common slot design Power management for redundant power configurations 24 Power supplies

25 HPE 1500W Common Slot Platinum Plus Hot Plug Power Supply Depending on the cartridges and switches installed, two to four power supplies are required to power the chassis. For more information, see Power supply population rules on page 39. The HPE 1500W Common Slot Platinum Plus Hot Plug Power Supply supports the following: Common slot design Power management for redundant power configurations HPE Moonshot 1500 Chassis Management Module The HPE Moonshot 1500 CM module is the gateway for system and network management. The Moonshot 1500 CM module is installed in the rear of the chassis. The Moonshot 1500 CM module has the following key features: Device neutral, low cost node solution IPMI and serial console for each server Single Ethernet port gateway HPE Moonshot ilo CM Firmware, which aggregates to a common set of management interfaces HPE APM rack management, which spans one rack or multiple racks True out-of-band firmware update services Service port to both switches for remote network management HPE Moonshot Remote Console Administrator The HPE Moonshot Remote Console Administrator (mrca), powered by HPE ilo 4, enables an IT administrator to interface with the Moonshot System. It supports the HPE Moonshot x86 cartridges. HPE 1500W Common Slot Platinum Plus Hot Plug Power Supply 25

26 The mrca has the following key features: Console support for initial OS installation and debug support The Moonshot ilo CM Firmware, which aggregates to a common set of management interfaces Keyboard, video, mouse, and virtual media for the connected Moonshot node USB 2.0 drive and M.2 connections (future support) for the connected Moonshot node x1 PCIe to 1 of 4 adjacent Moonshot cartridge nodes Drivers, firmware, and software updates Fans Before using your system for the first time, verify that you have the latest drivers, firmware, and system software installed. Update your system with the Moonshot Component Pack. For more information, see the Moonshot Component Pack Update Guide on the Hewlett Packard Enterprise website ( Verify the latest firmware is installed on Moonshot sub-systems: x86 cartridges mrca ilo Chassis Manager (minimum version 1.40) 2. After the firmware is updated, install the mrca and power-cycle the ilo Chassis Manager. 3. Clear the browser cache. Hewlett Packard Enterprise recommends using Internet Explorer 11 or later. Chrome and Firefox are not supported. When removing or replacing a fan, observe the following guidelines: Five fans ship standard with the chassis. To boot and operate the chassis, all five fans must be installed and operating. Each fan contains two rotors. If one rotor fails, the fan is degraded and continues to operate. The health LED on the degraded fan changes to red and a management event is logged. The chassis can operate normally with one degraded fan (one failed rotor) until that fan is replaced. 26 Drivers, firmware, and software updates

27 Always complete the removal and replacement of the new fan promptly to optimize cooling and performance. Be sure to order the correct fan spare part number for your chassis. For more information, see the server user and maintenance guide in the HPE Moonshot Information Library ( info/moonshot/docs). For more information, see Fan population rules on page 39. Cables Each fan module has the following key features: Common slot design Two rotors The following serial cables are required: DB9 Null Modem Cable (Female to Female) USB to DB9 Serial Adapter For part number information about the cables, see the HPE Moonshot 1500 Chassis Maintenance and Service Guide. For more information about cabling the HPE Moonshot 1500 Chassis, see the HPE Moonshot 1500 Chassis Setup and Installation Guide on the Hewlett Packard Enterprise website ( info/moonshot/docs). Cables 27

28 Software tools and solutions Product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the Hewlett Packard Enterprise website ( HPE Moonshot ilo Chassis Management Firmware The Moonshot ilo Chassis Management Firmware is the gateway for aggregated chassis management on the Moonshot System. As a single point of access to the chassis, ilo CM firmware enables you to configure, update, and operate the Moonshot System through the GUI, CLI, IPMI, and remote serial console access. For more information, see the HPE Moonshot ilo Chassis Management CLI User Guide in the Hewlett Packard Enterprise Information Library ( HPE Moonshot ilo CM Integrated Management Log The ilo CM IML records hundreds of events and stores them in an easy-to-view form. The ilo CM IML timestamps each event with 1-minute granularity. Logged events include fan, power supply, cartridge and switch insertion, removal or failure events, temperature events, and firmware updates. To view recorded events in the ilo CM IML, use the GUI or enter the show log iml all command in ilo CM firmware. For more information, see the HPE Moonshot ilo Chassis Management CLI User Guide in the Hewlett Packard Enterprise Information Library ( HPE Moonshot ilo CM Event Log The ilo CM Event Log is an operating system-independent log that maintains a record of events by date and time. Logged events include major events, such as a power outage or a reset, login events, node power on/off events, configuration changes, and ilo CM firmware events. To view recorded events in the ilo CM Event Log, use the GUI or enter show log ilo all command in ilo CM firmware. For more information, see thehpe Moonshot ilo Chassis Management CLI User Guide in the Hewlett Packard Enterprise Information Library ( HPE Insight Cluster Management Utility The Insight CMU is an efficient and robust hyperscale cluster lifecycle management framework and suite of tools for large Linux clusters. A simple graphical interface enables an at-a-glance view of the entire cluster across multiple metrics, provides frictionless scalable remote management and analysis, and allows rapid software provisioning to all system nodes. Insight CMU makes cluster management more user friendly, efficient, and error-free than if it were being managed by scripts, or on a node-by-node basis. Insight CMU is highly flexible and customizable, offers both GUI and CLI interfaces, and is used to deploy a range of software environments, from simple compute farms to highly customized, applicationspecific configurations. For more information on Insight CMU features and links to technical documentation, QuickSpecs, and a product demo, see the Hewlett Packard Enterprise website ( To download the product, go to the Hewlett Packard Enterprise Software Depot ( support/softwaredepot). Click Insight Management, then click Insight Cluster Management. 28 Software tools and solutions

29 HPE Moonshot Component Pack The Moonshot Component Pack is a comprehensive firmware solution tested on the Moonshot System and delivered as a compressed file. The compressed file includes all the component files needed to update a Moonshot System. Users deploy the firmware updates contained in the Moonshot Component Pack using the included Smart Update Manager, or by using the ilo Chassis Manager GUI or CLI, or the HPE Moonshot switch module CLI. Download the latest pack from the Hewlett Packard Enterprise website ( Smart Update Manager Smart Update Manager (SUM) is an application included with the HPE Edgeline Component Pack that provides a web-based GUI for installing and updating firmware on many Hewlett Packard Enterprise products, including the Edgeline System. Smart Update Manager has an integrated discovery engine that finds the installed hardware and current versions of firmware in use on nodes that you identify. This application installs updates in the correct order and ensures that all dependencies are net before deploying an update, and prevents an installation if there are version-based dependencies that it cannot resolve. The version of Smart Update Manager included with each HPE Edgeline Component Pack release is designed to be the best solution for installing Edgeline System firmware updates. Always use the included version of Smart Update Manager for Edgeline System updates. For more information, see the HPE Edgeline Component Pack Update Guide in the HPE Edgeline Information Library. HPE Moonshot Component Pack 29

30 Configuration rules Basic configuration rules Chassis configuration rules are dependent on the models and quantities of cartridges and switches installed, but consider the following basic rules: Fans must be installed in all fan bays. Sufficient power supplies must be installed to support the installed cartridges and switches. The internal switch module and external uplink module are a mated pair. If two switch modules are installed, two uplink modules are required. All internal and external slots and bays must be populated with modules or blanks for proper thermal cooling. Supported cartridge configurations The HPE Moonshot 1500 Chassis can be configured for either: Like cartridge configurations Supports up to 45 cartridges For more information on like cartridge configurations, see Like cartridge configuration population rules on page 32. Mix-match cartridge configurations Supports up to 45 cartridges, following these rules: Quad node cartridges require the HPE Moonshot 180G Switch. Cartridges with hard drives must be installed in front of cartridges without hard drives in a given column. For more information on hardware compatibility, see Hardware compatibility matrix on page 40. For more information on mixing cartridge types, see Mix-match cartridge configuration population rules on page Configuration rules

31 Chassis population rules Cartridge population rules Cartridge configuration rules are maintained by the chassis, as each cartridge reports its model information to the Moonshot 1500 CM module. When installing cartridges in the chassis, begin by populating cartridge slot 1 and install all cartridges in numerical order by slot number (slot 1, 2, 3, and so on). If the chassis is powered on when adding cartridges, observe the following requirements: Cartridges must be installed one at a time. Elapsed time between removing the blank and installing the cartridge must not exceed 30 seconds. m510-16c cartridge population rules The m510-16c cartridge must be installed before any other cartridges. When installing m510-16c cartridges in the chassis, begin by populating cartridge slot 1. Move down the column to slot 2. Then, move to slot 4 and slot 5. Continue populating in numerical order between rows 1 and 2. Do not populate m510-16c cartridges in cartridge slots in row 3. If a column contains a m510-16c cartridge, leave the cartridge slot in the third row of that column blank. Additionally, leave blank the third slot in the column to the right of the m510-16c cartridge. Chassis population rules 31

32 For example, if an m510-16c cartridge is installed in slots 1 and 2, then slots 3 and 6 must be blank. The m510-16c cartridge can be mixed with other cartridges, so as along as the population rules for those cartridges are followed. Like cartridge configuration population rules When populating the Moonshot 1500 Chassis with all like cartridges, the standard population rules apply. For more information, see Cartridge population rules on page Populate all like cartridges by column, starting with slot 1. The entire chassis does not need to be all of the same cartridge; however, each column should be populated with the same cartridge. 2. Install blanks in all empty slots. Sample like cartridge configuration Mix-match cartridge configuration population rules When populating the Moonshot 1500 Chassis using the mix-match cartridge configuration, the standard population rules apply. For more information, see Cartridge population rules on page If possible, populate all like cartridges by column, starting with slot Populate mix-match columns with any hard drive cartridges in front of cartridges without hard drives. For example, if populating a column with the ProLiant m300 Server Cartridge (which includes a hard drive) in a mix-match configuration, install the m300 in row 3, closest to the front of the chassis. 3. Install blanks in all empty slots. 4. For optimal network performance with the HPE Moonshot 180XGc Switch, use the following slotting rule: The HPE Moonshot 180XGc switch can be used with a mix of different cartridge type, such as onenode or four-node cartridges, with 1GbE or 10GbE NICs. When the number of 10GbE cartridges in a 32 Like cartridge configuration population rules

33 chassis is greater than 10, use a Moonshot 45XGc switch for best performance. When using 10GbE cartridges with the 180XGc switch, populate all cartridges in the front or rear row for best performance. Sample mix-match cartridge configuration Mix-match configuration with the Moonshot 45G Switch Mix-match configuration with the Moonshot180G Switch Sample mix-match cartridge configuration 33

34 mrca population rules The HPE Moonshot Remote Console Administrator (mrca), loaded with HPE ilo 4, enables an IT administrator to interface with the Moonshot System. It supports HPE Moonshot x86 server cartridges. For a current list of supported server cartridges, see the Hewlett Packard Enterprise website ( In order to interface with the specific server cartridge node, the mrca must be installed in a specific slot within the chassis, relative to the linking server cartridge. mrca recommended population rules If available, Hewlett Packard Enterprise recommends installing the linking server cartridge in slot #41, and then installing the mrca in the following slots to access the specific nodes of interest within that server cartridge. Item Description 1 Install the server cartridge to link and configure in slot #41. 2 To link and configure node 1 of the server cartridge, install the mrca in slot #44. Table Continued 34 mrca population rules

35 Item Description 3 To link and configure node 2 of the server cartridge, install the mrca in slot #40. 4 To link and configure node 3 of the server cartridge, install the mrca in slot #42. 5 To link and configure node 4 of the server cartridge, install the mrca in slot #38. mrca detailed population rules Hewlett Packard Enterprise recommends installing the linking cartridge in slot #41, and then following the mrca recommended population rules on page 34. However, if that option is unavailable for your chassis configuration, then install the mrca in the following slots, based on the linking cartridge slot and the node you want to link to. For example, if linking to node 2 of an HPE Moonshot m700 Cartridge installed in slot #25, the mrca must be installed in slot #27. NODE 1 NODE 2 NODE 3 NODE 4 Cartridge Slot mrca Slot Cartridge Slot mrca Slot Cartridge Slot mrca Slot Cartridge Slot 1 25 mrca Slot Table Continued mrca detailed population rules 35

36 NODE 1 NODE 2 NODE 3 NODE 4 Cartridge Slot mrca Slot Cartridge Slot mrca Slot Cartridge Slot mrca Slot Cartridge Slot mrca Slot Table Continued 36 Chassis population rules

37 NODE 1 NODE 2 NODE 3 NODE 4 Cartridge Slot mrca Slot Cartridge Slot mrca Slot Cartridge Slot mrca Slot Cartridge Slot mrca Slot Shading indicates where the mrca should be placed Chassis population rules 37

38 Linking node Node 1 Node 2 Node 3 Node 4 HPE Moonshot Server Cartridges HPE ProLiant m300 Server Cartridge HPE ProLiant m350 Server Cartridge HPE ProLiant m700 Server Cartridge HPE ProLiant m700p Server Cartridge HPE ProLiant m710 Server Cartridge HPE ProLiant m710p Server Cartridge HPE ProLiant m350 Server Cartridge HPE ProLiant m700 Server Cartridge HPE ProLiant m700p Server Cartridge HPE ProLiant m350 Server Cartridge HPE ProLiant m700 Server Cartridge HPE ProLiant m700p Server Cartridge HPE ProLiant m350 Server Cartridge HPE ProLiant m700 Server Cartridge HPE ProLiant m700p Server Cartridge Switch module and uplink module population rules When populating switch modules and uplink modules, always install the two as a pair. The pairs are not required to be installed in any order as long as both the switch module and uplink module are in the same bay number. When installing a switch module in switch module bay A, install the uplink module in uplink module bay A on the rear of the chassis. When installing a switch module in switch module bay B, install the uplink module in uplink module bay B on the rear of the chassis. The switch module and uplink module are companion devices, and both are required for normal operation. All slots must be populated with either a module or a blank. 38 Switch module and uplink module population rules

39 Power supply population rules Two to four power supplies can be installed in the chassis. The required number of power supplies varies, depending on the configuration. A minimum of two power supplies is required to boot the chassis. A minimum of three power supplies is required to be redundant. A maximum of four power supplies can be installed in the chassis. Hewlett Packard Enterprise recommends using the HPE Power Advisor to calculate the infrastructure required for your configuration and allow some flexibility for growth. Hewlett Packard Enterprise provides power sizing tools on the Hewlett Packard Enterprise website ( hpepoweradvisor). Fan population rules Five fans ship standard with the chassis. Each fan contains two rotors. To boot and run the chassis, a minimum of five fans must be installed with at least nine operational rotors. For a redundant configuration, all five fans (10 rotors) must be installed and operating. Power supply population rules 39

40 Hardware compatibility Hardware compatibility matrix The following hardware is supported in the HPE Moonshot 1500 Chassis. Component ProLiant m300 Server Cartridges ProLiant m350 Server Cartridges ProLiant m400 Server Cartridges ProLiant m510 Server Cartridges ProLiant m510-16c Server Cartridges ProLiant m700 Server Cartridges ProLiant m700p Server Cartridges ProLiant m710 Server Cartridges ProLiant m710p Server Cartridges ProLiant m710x Server Cartridges ProLiant m800 Server Cartridges Moonshot 1500 Chassis Management Module Moonshot-45G Switch Module Moonshot-180G Switch Module Moonshot-45Gc Switch Module Moonshot-45XGc Switch Module Moonshot-180XGc Switch Module Moonshot-6SFP Uplink Module Moonshot-4QSFP+ Uplink Module Moonshot-16SFP+ Uplink Module 1200W Common Slot Hot Plug Power Supply HPE 1500W Common Slot Hot Plug Power Supply HPE 1500W Common Slot 48VDC Input Hot-Plug Power Supply Fans Supported configuration in the chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 30 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis Up to 45 cartridges per chassis One module required per chassis Up to two switch modules per chassis when paired with supported uplink modules Up to two switch modules per chassis when paired with supported uplink modules Up to two switch modules per chassis when paired with supported uplink modules Up to two switch modules per chassis when paired with supported uplink modules Up to two switch modules per chassis when paired with supported uplink modules Up to two uplink modules when paired with supported switch modules Up to two uplink modules when paired with supported switch modules Up to two uplink modules when paired with supported switch modules At least two power supplies per chassis At least two power supplies per chassis At least two power supplies per chassis Five fans required per chassis 40 Hardware compatibility

41 The following tables represent components that are compatible within each chassis. Table 1: Switch and cartridge compatibility Cartridges Moonshot- 45G Switch Moonshot- 45Gc Switch Moonshot- 45XGc Switch Moonshot- 180G Switch Moonshot- 180XGc Switch 1Gb 1Gb 1Gb 10Gb 1Gb 1Gb 10Gb m300 Y Y Y Y Y m350 m400 m510 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only Y Y 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only m700 Y Y m700p Y Y m710 m710p m710x 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only Y Y Y 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only 1Gb speed only m800 Y Y Table 2: Switch and uplink module compatibility Y Y Y Y Y Uplink Modules Moonshot-6SF P Moonshot-4Q SFP Moonshot- 16SFP+ Moonshot- 45G Switch Moonshot- 45Gc Switch Moonshot- 45XGc Switch Moonshot- 180G Switch Moonshot- 180XGc Switch 1Gb 1Gb 1Gb 10Gb 1Gb 1Gb 10Gb Y Y Y Y Y Y Y Y Y Y Y Y Hardware compatibility 41

42 Table 3: Power and cooling component compatibility Cartridge ProLiant m300 Server Cartridge ProLiant m350 Server Cartridge ProLiant m400 Server Cartridge ProLiant m510 Server Cartridge ProLiant m700 Server Cartridge ProLiant m700p Server Cartridge ProLiant m710 Server Cartridge ProLiant m710p Server Cartridge ProLiant m710x Server Cartridge ProLiant m800 Server Cartridge 1200W Common Slot Platinum Plus Hot Plug Power Supply 1500W Common Slot Platinum Plus Hot Plug Power Supply 1500W Common Slot 48VDC Input Hot-Plug Power Supply Fans Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported Supported 42 Hardware compatibility

43 Software compatibility Software compatibility matrix Supported and tested companion firmware and software must be installed on Moonshot System components. For more information about updating firmware on Moonshot System components, see HPE Moonshot Component Pack on page 29. For information about operating systems supported by the Moonshot System, see the operating system support matrices Software compatibility 43

44 Device mapping Cartridge mapping Each cartridge has two ports per node, with each port connecting to one of the internal network switch modules and its corresponding uplink module. Understanding the software enumeration of Ethernet ports and the linkage to NIC/network hardware helps ensure that the network is properly configured and aids in troubleshooting. To determine the port mapping ID for a specific cartridge, determine the cartridge slot number and use the following table. Cartridge slot number OS device name Connects to internal switch module <cartridge slot number> eth0 Switch module A, port 1/0/<cartridge slot number> <cartridge slot number> eth1 Switch module B, port 1/0/<cartridge slot number> Connects to external uplink module port Uplink module A, any port Uplink module B, any port The following table provides specific examples using cartridge slot numbers 24 and 45. Cartridge slot number OS device name Connects to internal network switch 24 eth0 Switch module A, port 1/0/24 24 eth1 Switch module B, port 1/0/24 45 eth0 Switch module A, port 1/0/45 45 eth1 Switch module B, port 1/0/45 Connects to external uplink module port Uplink module A, any port Uplink module B, any port Uplink module A, any port Uplink module B, any port For more information about cartridge mapping, see the "Port naming convention" section in the Moonshot Networking Cookbook in the HPE Moonshot Information Library ( docs). 44 Device mapping

45 Warranty and regulatory information Warranty information To view the warranty for your product or to view the Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products reference document, go to the Enterprise Safety and Compliance website: Additional warranty information HPE ProLiant and x86 Servers and Options HPE Enterprise Servers HPE Storage Products HPE Networking Products Regulatory information To view the regulatory information for your product, view the Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise Support Center: Additional regulatory information Hewlett Packard Enterprise is committed to providing our customers with information about the chemical substances in our products as needed to comply with legal requirements such as REACH (Regulation EC No 1907/2006 of the European Parliament and the Council). A chemical information report for this product can be found at: For Hewlett Packard Enterprise product environmental and safety information and compliance data, including RoHS and REACH, see: For Hewlett Packard Enterprise environmental information, including company programs, product recycling, and energy efficiency, see: Belarus Kazakhstan Russia marking Manufacturer and Local Representative Information Warranty and regulatory information 45

46 Manufacturer information: Hewlett Packard Enterprise Company, 3000 Hanover Street, Palo Alto, CA U.S. Local representative information Russian: Russia: Belarus: Kazakhstan: Local representative information Kazakh: Russia: Belarus: Kazakhstan: Manufacturing date: The manufacturing date is defined by the serial number. CCSYWWZZZZ (serial number format for this product) Valid date formats include: YWW, where Y indicates the year counting from within each new decade, with 2000 as the starting point; for example, 238: 2 for 2002 and 38 for the week of September 9. In addition, 2010 is indicated by 0, 2011 by 1, 2012 by 2, 2013 by 3, and so forth. YYWW, where YY indicates the year, using a base year of 2000; for example, 0238: 02 for 2002 and 38 for the week of September 9. Turkey RoHS material content declaration 46 Turkey RoHS material content declaration

47 Ukraine RoHS material content declaration Ukraine RoHS material content declaration 47

48 Electrostatic discharge Preventing electrostatic discharge Procedure To prevent damaging the system, be aware of the precautions you must follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact the Hewlett Packard Enterprise Support Center. 48 Electrostatic discharge

HP ProLiant m300 1P C2750 CPU 32GB Configure-to-order Server Cartridge B21

HP ProLiant m300 1P C2750 CPU 32GB Configure-to-order Server Cartridge B21 Overview HP Moonshot System with the HP ProLiant m300 server cartridge was created for cost-effective Dynamic Content Delivery, frontend Web and online analytics. The ProLiant m300 server cartridge has

More information

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes Part Number: 732171-007 Published: February 2017 Edition: 1 2017 Hewlett Packard Enterprise Development LP Notices The information contained

More information

HPE Integrity MC990 X Server Getting Started Guide

HPE Integrity MC990 X Server Getting Started Guide HPE Integrity MC990 X Server Getting Started Guide Abstract This guide describes the HPE Integrity MC990 X Server computer system and provides information to get started using it. Part Number: 855699-003

More information

HP Moonshot Switch User and Maintenance Guide

HP Moonshot Switch User and Maintenance Guide HP Moonshot Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identification, setup, installation,

More information

HP ProLiant Moonshot Server User and Maintenance Guide

HP ProLiant Moonshot Server User and Maintenance Guide HP ProLiant Moonshot Server User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots cartridges. This guide describes identification and

More information

QuickSpecs. HP ProLiant m710 Server Cartridge. Overview. HP ProLiant m710 Server Cartridge. Retired

QuickSpecs. HP ProLiant m710 Server Cartridge. Overview. HP ProLiant m710 Server Cartridge. Retired Overview HP Moonshot System with the HP ProLiant m710 server cartridge is designed to enhance the performance of Rich Application Streaming and Video Transcoding. The ProLiant m710 server cartridge has

More information

HP Moonshot-45XGc Switch User and Maintenance Guide

HP Moonshot-45XGc Switch User and Maintenance Guide HP Moonshot-45XGc Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identification, setup,

More information

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated

More information

HPE Synergy Configuration and Compatibility Guide

HPE Synergy Configuration and Compatibility Guide HPE Synergy Configuration and Compatibility Guide Abstract This guide describes HPE Synergy hardware configuration options and compatibility. Hewlett Packard Enterprise assumes you are qualified in the

More information

HPE Edgeline EL4000 System User Guide

HPE Edgeline EL4000 System User Guide HPE Edgeline EL4000 System User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

Hosted Desktops Infrastructure

Hosted Desktops Infrastructure Hosted Desktops Infrastructure May 2014 Aligning to PC User segmentation High Density Session / App Virtualization Virtual desktops (VDI) App / Desktop virtualization with graphics acceleration GAP Client

More information

HP ProLiant DL385p Gen8 Server

HP ProLiant DL385p Gen8 Server DATASHEET Gen8 Server Flexibility to future-proof your infrastructure HP Proliant DL385 servers offer low list prices and high rewards The Gen8 server is purpose-built to: Redefine the customer experience

More information

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 Abstract This document contains setup, installation, and configuration information for HPE Virtual Connect. This document

More information

HPE Edgeline EL4000 System User Guide

HPE Edgeline EL4000 System User Guide HPE Edgeline EL4000 System User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

HPE ProLiant ML350 Gen10 Server

HPE ProLiant ML350 Gen10 Server Digital data sheet HPE ProLiant ML350 Gen10 Server ProLiant ML Servers What's new Support for Intel Xeon Scalable processors full stack. 2600 MT/s HPE DDR4 SmartMemory RDIMM/LRDIMM offering 8, 16, 32,

More information

Moonshot Component Pack

Moonshot Component Pack Moonshot Component Pack 2016.07.0 Release Notes Part Number: 725026-403a Published: July 2016 Edition: 4 Copyright 2014, 2016 Hewlett Packard Enterprise Development LP The information contained herein

More information

HP ProLiant BL35p Server Blade

HP ProLiant BL35p Server Blade Data sheet The new HP ProLiant BL35p two-way Server Blade delivers uncompromising manageability, maximum compute density and breakthrough power efficiencies to the high-performance data centre. The ProLiant

More information

HPE ProLiant ML350 Gen P 16GB-R E208i-a 8SFF 1x800W RPS Solution Server (P04674-S01)

HPE ProLiant ML350 Gen P 16GB-R E208i-a 8SFF 1x800W RPS Solution Server (P04674-S01) Digital data sheet HPE ProLiant ML350 Gen10 4110 1P 16GB-R E208i-a 8SFF 1x800W RPS Solution Server (P04674-S01) ProLiant ML Servers What's new Support for Intel Xeon Scalable processors full stack. 2600

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

HPE ProLiant DL360 Gen P 16GB-R P408i-a 8SFF 500W PS Performance Server (P06453-B21)

HPE ProLiant DL360 Gen P 16GB-R P408i-a 8SFF 500W PS Performance Server (P06453-B21) Digital data sheet HPE ProLiant DL360 Gen10 4110 1P 16GB-R P408i-a 8SFF 500W PS Performance Server (P06453-B21) ProLiant DL Servers What's new Innovative design with greater flexibility to mix and match

More information

The HP Blade Workstation Solution A new paradigm in workstation computing featuring the HP ProLiant xw460c Blade Workstation

The HP Blade Workstation Solution A new paradigm in workstation computing featuring the HP ProLiant xw460c Blade Workstation The HP Blade Workstation Solution A new paradigm in workstation computing featuring the HP ProLiant xw460c Blade Workstation Executive overview...2 HP Blade Workstation Solution overview...2 Details of

More information

HPE ProLiant WS460c Gen9 Graphics Server Blade User Guide

HPE ProLiant WS460c Gen9 Graphics Server Blade User Guide HPE ProLiant WS460c Gen9 Graphics Server Blade User Guide Abstract This guide provides operation information for the HPE ProLiant WS460c Graphics Server Blade. This guide is for technicians that install,

More information

HP BladeSystem c-class Enclosure Troubleshooting Guide

HP BladeSystem c-class Enclosure Troubleshooting Guide HP BladeSystem c-class Enclosure Troubleshooting Guide Part Number 460224-002 July 2009 (Second Edition) Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

HP ProLiant DL360 G7 Server - Overview

HP ProLiant DL360 G7 Server - Overview Menu Hewlett Packard Enterprise Support Center Search Notifications Help Settings HP ProLiant DL360 G7 Server - Overview Product description What's new Product features Software overview Important links

More information

HPE ProLiant BL460c Gen9 Server Blade User Guide

HPE ProLiant BL460c Gen9 Server Blade User Guide HPE ProLiant BL460c Gen9 Server Blade User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you

More information

HPE 3PAR OS MU2 Patch 53 Release Notes

HPE 3PAR OS MU2 Patch 53 Release Notes HPE 3PAR OS 3.2.2 MU2 Patch 53 Release Notes Abstract This release notes document is for Patch 53 and intended for HPE 3PAR Operating System Software 3.2.2.390 (MU2). Part Number: QL226-99481 Published:

More information

HP Virtual Connect for c-class BladeSystem Setup and Installation Guide

HP Virtual Connect for c-class BladeSystem Setup and Installation Guide HP Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.01 Abstract This document contains setup, installation, and configuration information for HP Virtual Connect. This document

More information

Integrated Smart Update Tools for Windows and Linux User Guide

Integrated Smart Update Tools for Windows and Linux User Guide Integrated Smart Update Tools for Windows and Linux User Guide Version 2.2.0 Abstract This document describes how to use Integrated Smart Update Tools to update firmware and operating system drivers on

More information

HPE ProLiant DL580 Gen10 Server

HPE ProLiant DL580 Gen10 Server Digital data sheet HPE ProLiant DL580 Gen10 Server ProLiant DL Servers What's new Support for the new Intel Xeon Scalable Gold 6143 and Intel Xeon Scalable Platinum 8165 processors which support core boosting

More information

HPE ProLiant BL660c Gen9 Server Blade User Guide

HPE ProLiant BL660c Gen9 Server Blade User Guide HPE ProLiant BL660c Gen9 Server Blade User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you

More information

HP Eight-Port SAS/SATA RAID Host Bus Adapter

HP Eight-Port SAS/SATA RAID Host Bus Adapter HP Eight-Port SAS/SATA RAID Host Bus Adapter Installation Guide June 2006 (Second edition) Part Number 377610-002 Legal notices Copyright 2005, 2006 Hewlett-packard Development Company, L.P. The information

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

HP BladeSystem c-class Ethernet network adaptors

HP BladeSystem c-class Ethernet network adaptors HP BladeSystem c-class Ethernet network adaptors Family data sheet NC325m Quad-port Gigabit NC326m Dual-port Gigabit NC360m Dual-port Gigabit NC364m Quad-port Gigabit NC382m Dual-port Multifunction Gigabit

More information

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install HP Proliant DL360 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: COOPE-RRTF1 Published: September 2010 Edition: 1 Copyright 2010 Hewlett-Packard Development Company,

More information

HPE ProLiant ML110 Gen10 Server

HPE ProLiant ML110 Gen10 Server Digital data sheet HPE ProLiant ML110 Gen10 Server ProLiant ML Servers What's new New SMB focused offers regionally released as Smart Buy Express in the U.S. and Canada, Top Value in Europe, and Intelligent

More information

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007 Sun StorageTek nl 1U Rackmount Media Tray Reference Guide Sun Doc Part Number: 875 4297 10 Second edition: December 2007 Legal and notice information Copyright 2007 Hewlett Packard Development Company,

More information

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version

More information

HPE ProLiant DL580 Gen10 Server

HPE ProLiant DL580 Gen10 Server HPE ProLiant DL580 Gen10 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots HPE server systems. Hewlett Packard Enterprise assumes you are qualified

More information

HPE ProLiant DL380 Gen10 Server User Guide

HPE ProLiant DL380 Gen10 Server User Guide HPE ProLiant DL380 Gen10 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are

More information

QuickSpecs. HPE Cloudline CL7100 Server. Overview

QuickSpecs. HPE Cloudline CL7100 Server. Overview Overview The is Open Compute Compliant and is designed for service providers that need very high density compute platforms for Open Rack deployment. The CL7100 is based upon the OCPv1 (Open Compute Project)

More information

NEC Express5800/B120f-h System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide NEC Express5800/B120f-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HPE VMware ESXi and vsphere. Part Number: 818330-003 Published: April

More information

HP Moonshot System The world s first software defined servers

HP Moonshot System The world s first software defined servers Technical white paper HP Moonshot System The world s first software defined servers Table of contents Introduction... 2 Challenges facing today s data center... 2 HP Moonshot System... 2 HP Moonshot 1500

More information

Transform your data center cost-effectively with the ultra-dense, efficient, and high-performance HP ProLiant DL320 G6 enterpriseclass

Transform your data center cost-effectively with the ultra-dense, efficient, and high-performance HP ProLiant DL320 G6 enterpriseclass HP ProLiant DL320 G6 Server Data sheet Transform your data center cost-effectively with the ultra-dense, efficient, and high-performance HP ProLiant DL320 G6 enterpriseclass rack server Would you consider

More information

HPE ProLiant DL580 Gen10 Server User Guide

HPE ProLiant DL580 Gen10 Server User Guide HPE ProLiant DL580 Gen10 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots HPE server systems. Hewlett Packard Enterprise assumes that you are qualified

More information

QuickSpecs HPE Hyper Converged 380

QuickSpecs HPE Hyper Converged 380 Overview HPE Hyper Converged 380 For customers who are looking for a configurable, scalable, agile and highly available hyper converged virtualization system, the new HPE Hyper Converged 380 (HC 380) delivers

More information

QuickSpecs. Models. HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter. Overview

QuickSpecs. Models. HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter. Overview Overview The HP NC380T server adapter is the industry's first PCI Express dual port multifunction network adapter supporting TOE (TCP/IP Offload Engine) for Windows, iscsi (Internet Small Computer System

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

HPE ProLiant ML110 Gen P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P )

HPE ProLiant ML110 Gen P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P ) Digital data sheet HPE ProLiant ML110 Gen10 3104 1P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P03684-425) ProLiant ML Servers What's new New SMB focused offers regionally released as Smart

More information

Introduction to HPE ProLiant Servers HE643S

Introduction to HPE ProLiant Servers HE643S Course data sheet Introduction to HPE ProLiant Servers HE643S HPE course number Course length Delivery mode View schedule, local pricing, and register View related courses HE643S 2 Days ILT, VILT View

More information

HPE Altoline XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline XG 6QSFP+ x86 ONIE AC Back-to-Front Switch

HPE Altoline XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline XG 6QSFP+ x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6920 48XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline 6920 48XG 6QSFP+ x86 ONIE AC Back-to-Front Switch JL167A JL168A Key features High 10GbE port density and low

More information

HPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes

HPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes HPE BladeSystem c-class Virtual Connect Support Utility Version 1.12.0 Release Notes Abstract This document provides release information for the HPE BladeSystem c-class Virtual Connect Support Utility

More information

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series Overview Models HPE Altoline 6921 48SFP+ 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline 6921 48SFP+ 6QSFP+ x86 ONIE AC Back-to-Front Switch HPE Altoline 6921 48XGT 6QSFP+ x86 ONIE AC Front-to-Back

More information

HPE ProLiant MicroServer Gen10 User Guide

HPE ProLiant MicroServer Gen10 User Guide HPE ProLiant MicroServer Gen10 User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations Overview ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations 1. MSA1000 6. Fibre Channel Interconnect #1 and #2 2. Smart Array Controller 7. Ethernet "HeartBeat"

More information

All-new HP ProLiant ML350p Gen8 Server series

All-new HP ProLiant ML350p Gen8 Server series Data sheet All-new HP ProLiant ML350p Gen8 Server series Performance server with increased expandability and availability The HP ProLiant ML350p Gen8 Server series comes with a winning combination of increased

More information

HPE ProLiant ML30 Gen9 Server User Guide

HPE ProLiant ML30 Gen9 Server User Guide HPE ProLiant ML30 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

GW2000h w/gw175h/q F1 specifications

GW2000h w/gw175h/q F1 specifications Product overview The Gateway GW2000h w/ GW175h/q F1 maximizes computing power and thermal control with up to four hot-pluggable nodes in a space-saving 2U form factor. Offering first-class performance,

More information

Retired. Models HPE Altoline QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP+ x86 ONIE AC Back-to-Front Switch

Retired. Models HPE Altoline QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP+ x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6940 32QSFP+ PPC ONIE AC Front-to-Back Switch HPE Altoline 6940 32QSFP+ PPC ONIE AC Back-to-Front Switch HPE Altoline 6940 32QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline

More information

HPE ProLiant MicroServer Gen10 User Guide

HPE ProLiant MicroServer Gen10 User Guide HPE ProLiant MicroServer Gen10 User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes HP BladeSystem c-class Virtual Connect Support Utility Version 1.9.1 Release Notes Abstract This document provides release information for the HP BladeSystem c-class Virtual Connect Support Utility Version

More information

HP ProLiant SL160z G6 Server

HP ProLiant SL160z G6 Server HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components

More information

QuickSpecs. HPE Cloudline CL3150 G4 Server. Overview

QuickSpecs. HPE Cloudline CL3150 G4 Server. Overview Overview The HPE Cloudline CL3150 G4 is a new 1U 1P AMD EPYC dense fast storage server for Cloud Service Providers that Features the latest AMD EPYC 7000 series processors, choice 24NVMe or 22NVMe + 2

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

HPE ConvergedSystem 500 for SAP HANA Scale-up Configurations

HPE ConvergedSystem 500 for SAP HANA Scale-up Configurations HPE ConvergedSystem 500 for SAP HANA Scale-up Configurations Administration, Operations, and Troubleshooting Guide Abstract This document is intended to assist SAP solution architects, SAP database and

More information

Hardware Reference Guide For Thin Clients

Hardware Reference Guide For Thin Clients b Hardware Reference Guide For Thin Clients Document Part Number: 254241-001 July 2002 This book provides basic hardware information for this series of Compaq Thin Clients. Å WARNING: Ä CAUTION: 2002 Compaq

More information

HP BladeSystem c-class Ethernet network adapters

HP BladeSystem c-class Ethernet network adapters HP BladeSystem c-class Ethernet network adapters Family data sheet HP NC552m 10 Gb Dual Port Flex-10 Ethernet Adapter HP NC551m Dual Port FlexFabric 10 Gb Converged Network Adapter HP NC550m 10 Gb Dual

More information

HPE Synergy 480 Gen9 Compute Module User Guide

HPE Synergy 480 Gen9 Compute Module User Guide HPE Synergy 480 Gen9 Compute Module User Guide Abstract This document is for the person who installs, administers, and troubleshoots the HPE Synergy system. Hewlett Packard Enterprise assumes you are qualified

More information

HPE Edgeline EL1000 System User Guide

HPE Edgeline EL1000 System User Guide HPE Edgeline EL1000 System User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

HPE ilo Federation User Guide for ilo 5

HPE ilo Federation User Guide for ilo 5 HPE ilo Federation User Guide for ilo 5 Abstract This guide explains how to configure and use the HPE ilo Federation features. It is intended for system administrators, Hewlett Packard Enterprise representatives,

More information

HP 10GbE Pass-Thru Module

HP 10GbE Pass-Thru Module Overview The is designed for c-class BladeSystem and HP Integrity Superdome 2 customers requiring a nonblocking, one -to-one connection between each server and the network. The pass-thru module provides

More information

HP ProLiant blade planning and deployment

HP ProLiant blade planning and deployment HP ProLiant blade planning and deployment Chris Powell CSG Products, Services, and Solutions Training Hewlett-Packard 2004 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

HPE ProLiant MicroServer Gen10 Troubleshooting Guide

HPE ProLiant MicroServer Gen10 Troubleshooting Guide HPE ProLiant MicroServer Gen10 Troubleshooting Guide Abstract This document describes common procedures and solutions for troubleshooting the HPE ProLiant MicroServer Gen10. This document is intended for

More information

Intelligent Provisioning 1.64(B) Release Notes

Intelligent Provisioning 1.64(B) Release Notes Intelligent Provisioning 1.64(B) Release Notes Part Number: 680065-407 Published: March 2017 Edition: 1 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein is subject

More information

HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide

HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide Abstract This guide is for HPE StoreOnce System Administrators. It assumes that the user has followed the instructions

More information

NEC Express5800/B110d Configuration Guide

NEC Express5800/B110d Configuration Guide NEC Express5800/B110d Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

HPE Moonshot ilo Chassis Management Web Interface

HPE Moonshot ilo Chassis Management Web Interface HPE Moonshot ilo Chassis Management Web Interface User Guide Abstract This guide provides information about configuring, updating, and operating HPE Moonshot Systems by using the Moonshot ilo Chassis Management

More information

NEC Express5800/B120e-h System Configuration Guide

NEC Express5800/B120e-h System Configuration Guide NEC Express5800/B120e-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6960 32QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline 6960 32QSFP28 x86 ONIE AC Back-to-Front Switch JL279A JL280A Key features High 100GbE port density and low latency

More information

HP ProLiant ML370 G4 Storage Server

HP ProLiant ML370 G4 Storage Server HP ProLiant ML370 G4 Storage Server Data sheet The HP ProLiant ML370 Storage Server is ideal for price conscious small to medium business (SMB) or remote offices that need more performance and scalability

More information

CSU 0111 Compute Sled Unit

CSU 0111 Compute Sled Unit CSU 0111 Compute Sled Unit Ericsson Software Defined Infrastructure Ericsson Compute Sled Unit (CSU) 0111 is a self-managed compute resource designed to slide into the CPA 111 chassis. Four CSUs can fit

More information

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory July 2003 (Second Edition) Part Number 325398-002 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows

More information

HP Moonshot System for WaaS

HP Moonshot System for WaaS HP Moonshot System for WaaS Jaynee Costanzo, Moonshot Product Mgr, AMS Jaynee.costanzo@hp.com Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide

HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide HP Part Number: Part Number 530778-003 Published: May 2010 (Fourth Edition) Notices Copyright 2009, 2010 Hewlett-Packard Development

More information

Hewlett Packard Enterprise StoreOnce 3100, 3500 and 5100 System Installation and Configuration Guide

Hewlett Packard Enterprise StoreOnce 3100, 3500 and 5100 System Installation and Configuration Guide Hewlett Packard Enterprise StoreOnce 3100, 3500 and 5100 System Installation and Configuration Guide Abstract This guide is for HPE StoreOnce System Administrators. It assumes that the user has followed

More information

Intelligent Provisioning 1.70 Release Notes

Intelligent Provisioning 1.70 Release Notes Intelligent Provisioning 1.70 Release Notes Part Number: 680065-408 Published: October 2017 Edition: 1 Copyright 2012, 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein

More information

QuickSpecs. Models. HP NC510C PCIe 10 Gigabit Server Adapter. Overview

QuickSpecs. Models. HP NC510C PCIe 10 Gigabit Server Adapter. Overview Overview The NC510C is a x8 PCI Express (PCIe) 10 Gigabit Ethernet CX4 (10GBASE-CX4 copper) network solution offering the highest bandwidth available in a ProLiant Ethernet adapter. This high-performance,

More information

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview. Overview HP 6 Port SATA RAID controller provides customers with new levels of fault tolerance for low cost storage solutions using SATA hard drive technologies. Models SATA RAID Controller 372953-B21 DA

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Models HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

Models HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch Overview Models HPE Altoline 6960 32QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline 6960 32QSFP28 x86 ONIE AC Back-to-Front Switch JL279A JL280A Key features High 100GbE port density and low latency

More information

HP ProLiant BL280c G6 Server Blade User Guide

HP ProLiant BL280c G6 Server Blade User Guide HP ProLiant BL280c G6 Server Blade User Guide Abstract This document describes installation, administration, and troubleshooting for this server blade. This document is for the person who installs, administers,

More information

10GbE Pass-Thru Module II for HPE BladeSystem c-class Enclosures User Guide

10GbE Pass-Thru Module II for HPE BladeSystem c-class Enclosures User Guide 10GbE Pass-Thru Module II for HPE BladeSystem c-class Enclosures User Guide Abstract This guide details using the command-line interface for configuration, operation, and management of the 10GbE Pass-Thru

More information

NEC Express5800/B120d-h System Configuration Guide

NEC Express5800/B120d-h System Configuration Guide NEC Express5800/B120d-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

CPMD Performance Benchmark and Profiling. February 2014

CPMD Performance Benchmark and Profiling. February 2014 CPMD Performance Benchmark and Profiling February 2014 Note The following research was performed under the HPC Advisory Council activities Special thanks for: HP, Mellanox For more information on the supporting

More information

SNAP Performance Benchmark and Profiling. April 2014

SNAP Performance Benchmark and Profiling. April 2014 SNAP Performance Benchmark and Profiling April 2014 Note The following research was performed under the HPC Advisory Council activities Participating vendors: HP, Mellanox For more information on the supporting

More information

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Altos R320 F3 Specifications. Product overview. Product views. Internal view Product overview The Altos R320 F3 single-socket 1U rack server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities effectively handle SMB

More information

HP StorageWorks. 3Gb SAS BL Switch User Guide

HP StorageWorks. 3Gb SAS BL Switch User Guide HP StorageWorks 3Gb SAS BL Switch User Guide The HP StorageWorks 3Gb SAS BL Switch (3Gb SAS BL Switch) is a single-wide interconnect module for HP BladeSystem c-class enclosures. The 3Gb SAS BL Switch

More information

HostEngine 5URP24 Computer User Guide

HostEngine 5URP24 Computer User Guide HostEngine 5URP24 Computer User Guide Front and Rear View HostEngine 5URP24 (HE5URP24) computer features Intel Xeon Scalable (Skylake FCLGA3647 socket) Series dual processors with the Intel C621 chipset.

More information

Newest generation of HP ProLiant DL380 takes #1 position overall on Oracle E-Business Suite Small Model Benchmark

Newest generation of HP ProLiant DL380 takes #1 position overall on Oracle E-Business Suite Small Model Benchmark Newest generation of HP ProLiant DL380 takes #1 position overall on Oracle E-Business Suite Small Model Benchmark ProLiant DL380 G6 uses latest Intel Xeon X5570 technology for ultimate performance HP Leadership

More information

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Lot # 10 - Servers. 1. Rack Server. Rack Server Server 1. Rack Server Rack Server Server Processor: 1 x Intel Xeon E5 2620v3 (2.4GHz/6 core/15mb/85w) Processor Kit. Upgradable to 2 CPU Chipset: Intel C610 Series Chipset. Intel E5 2600v3 Processor Family. Memory:

More information