10GbE Pass-Thru Module II for HPE BladeSystem c-class Enclosures User Guide
|
|
- Denis Strickland
- 5 years ago
- Views:
Transcription
1 10GbE Pass-Thru Module II for HPE BladeSystem c-class Enclosures User Guide Abstract This guide details using the command-line interface for configuration, operation, and management of the 10GbE Pass-Thru Module II for HPE BladeSystem c-class Enclosures. Part Number: Published: January 2019 Edition: 3
2 Contents Introduction... 4 Overview... 4 Component identification...5 Pass-thru connection identification... 5 Pass-thru LED identification...5 Installing and replacing a module... 7 Installing a pass-thru module... 7 Replacing an existing module... 7 Installing SFP+ tranceivers... 8 Firmware updates Updating the firmware image using the Onboard Administrator CLI...10 Command line Command line overview...13 Commands...14 General commands...14 CLS...14 HELP...14 HISTORY INTERFACE...14 LOG...15 SUPPORT VERSION LED...16 PACKAGE RESET...17 SERVER XMODEM Troubleshooting No traffic flow with link up and LED on...18 Health status LED flashing amber Health LED is not on Cannot access the pass-thru module serial console interface from Onboard Administrator PTM II console not working properly after sending BREAK from OA No link LED appears, even after plugging the cable into the SFP+module The download times out after starting to download the firmware file Sync error in log
3 Junk characters appear before PTM II CLI Prompt while connecting the console the first time after the module is powered on...23 Websites Support and other resources...26 Accessing Hewlett Packard Enterprise Support Accessing updates...26 Customer self repair...27 Remote support Warranty information...27 Regulatory information...28 Documentation feedback Acronyms...29 Acronyms and abbreviations
4 Introduction Overview The 10GbE Pass-Thru Module II is a high performance managed Pass-Thru Module for HPE C-Class blade systems. It provides 16 downlink ports with 1/10Gbps port connectivity to 16 blades in the enclosure that extends to 16 SFP+ ports with 1/10Gbps port connectivity on the front panel. 4 Introduction
5 Component identification Pass-thru connection identification Pass-thru LED identification Item Description 1 UID blue On = Activated Off = Deactivated 2 Internal health LED color Off = Normal (Power is off) Table Continued Component identification 5
6 Green = Normal (Power is on) Amber = Problem (A fault exists) 3 Port ID Green = Link is 10G Flashing green = 10G link activity is detected Amber = Link is 1G Flashing amber = 1G link activity is detected 4 Port 12 LED Green = Link is 10G Flashing green = 10G link activity is detected Amber = Link is 1G Flashing amber = 1G link activity is detected 5 Port 16 LED Green = Link is 10G Flashing green = 10G link activity is detected Amber = Link is 1G Flashing amber = 1G link activity is detected 6 Reset button 7 Reserved 6 Component identification
7 Installing and replacing a module Installing a pass-thru module NOTE: The pass-thru module may look different from that shown. Procedure 1. Open the handle. 2. Insert the pass-thru module into the bay (1). 3. Close the handle (2). Replacing an existing module CAUTION: Removing the pass-thru module from a powered enclosure results in the loss of network communications between the server blade network ports and the network infrastructure. For continued blade-server network communication and services availability before removing the module, redirect critical high-availability services or applications to use the redundant network ports. CAUTION: Do not connect the pass-thru module until after configuration. Procedure 1. Remove and label the cables. 2. Remove the module. Installing and replacing a module 7
8 Installing SFP+ tranceivers Prerequisites Disconnect all cables before removing or installing an SFP+ tranceiver. CAUTION: Observe all ESD precautions. Failure to do so can result in damage to the equipment. NOTE: The HPE 10GBase-T SFP+ Transceiver ( B21) is only configurable using 10Gbps. Pass- Thru Module II does not support 1Gbps. Hewlett Packard Enterprise recommends wearing an approved wrist strap when you handle any ESDsensitive device to eliminate possible ESD damage to equipment. Connect the wrist strap cord directly to earth ground. Procedure 1. Remove the dust plug and save for future use. When not using the SFP+ transceiver and cable, be sure to install the dust plugs on both. The plugs and caps protect the SFP+ transceiver ports and cables from contamination and ambient light. 2. Insert the SFP+ transceiver, and then close the latch. Be sure that the transceiver is fully seated and secure. 8 Installing and replacing a module
9 If you are installing the SFP+ transceiver into the bottom row of the module, rotate the SFP+ transceiver 180 degrees from the position shown in the illustration before installing the transceiver. 1 2 Installing and replacing a module 9
10 Firmware updates Updating the firmware image using the Onboard Administrator CLI The firmware update uses the Onboard Administrator Xmodem support with a firmware file hosted on an HTTP, FTP, or TFTP server. The firmware transfer can take up to seven minutes to complete. Procedure 1. Access the Onboard Administrator CLI remotely using one of the following methods: a. Remote access Telnet SSH b. Local access Serial connection to the active Onboard Administrator DB9 serial connector VGA and keyboard connected to the enclosure KVM ports For more information on how to access the Onboard Administrator CLI, see the HPE BladeSystem Onboard Administrator User Guide. 2. Log in to the active Onboard Administrator with a valid username and password that has a role on the Onboard Administrator allowing access to the pass-thru interconnect module. The pass-thru module in the following example is located in interconnect bay 2. Wherever the 2 appears, substitute the number of the interconnect bay your pass-thru module is installed into. 3. At the Onboard Administrator prompt, enter connect interconnect 2. The following message appears: NOTICE: This pass-thru connection to the integrated I/O console is provided for convenience and does not supply additional access control. For security reasons, use the password features of the integrated switch. Connecting to integrated switch 2 at ,N81... Escape character is '<Ctrl>_' (Control + Shift + Underscore) Press [Enter] to display the switch console: 4. To display the pass-thru module console, press Enter. 5. At the 10GbE Pass-Thru [CMD] prompt, enter version. The following message appears: [CMD] version HPE 1/10Gb Pass-thru Module (10GbE-PT) Management Processor c. Copyright 2017 Hewlett Packard Enterprise Development LP All rights reserved Package Name: 10Gb_PTM 10 Firmware updates
11 Package Version: 1.00 Package Build Time: 2016/12/14 3:39:23 Firmware Version: 1.00 BCM82328 ucode Version: 0010 BCM82780 ucode Version: 0028 CPLD ucode Version: 02 [OK] [CMD] 6. At the [CMD] prompt, enter xmodem. The following message appears: [CMD] xmodem CCCCCCCC 7. The module console begins to print C characters until the Xmodem transfer begins. There is a 30 seconds time out defined for the transfer of the package. Be sure that the downloadable package file path (for example, tftp://tftpserveripaddress/10gb_ptm_r1.10.pkg seen in step 10) is ready before step 6. (The recommended method is to add this URL in your paste buffer before step 6 so that you can paste this URL at step 10 instead of typing it). If the module times out, it will give a CMD prompt with a sync error in log messages. Restart the process. 8. Press Ctrl + Shift + _. The following message appears: Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > 9. Enter x while "CCCC" continues to be printed. The following message appears: Xmodem Send: Send a file to the interconnect module using the xmodem transfer protocol. The file can be downloaded to the OA from an HTTP(S), FTP, or TFTP server. After the file has been downloaded, the OA will transfer it to the switch. Please enter the URL below. Enter URL: 10. Enter the transfer URL tftp://tftpserveripaddress/10gb_ptm_r1.10.pkg. The following message appears: Downloading file... successful (transferred bytes) Continue with transfer (yes/no)? 11. Enter yes. The following message appears: Starting transfer. Press '<Ctrl>_' (Control + Shift + Underscore) to cancel. Note: The transfer will terminate after 30 seconds of inactivity done. 12. The pass-thru module displays multiple lines of. characters until the entire firmware transfer is complete. The following message appears: [OK] [CMD] 13. Enter the package validate command. The following message appears: [CMD] package validate Firmware updates 11
12 [OK] [CMD] 14. Enter the package apply command. The following message appears: [CMD] package apply [OK] [CMD] 15. Enter the package activate command. The following message appears: [CMD] package activate Reseting HPE 1/10Gbps Ethernet Switch Pass-thru, standby. 16. To determine the updated firmware version, use the version command. [CMD] version HPE 1/10Gb Pass-thru Module (10GbE-PT) Management Processor c) Copyright 2019 Hewlett Packard Enterprise Development LP All rights reserved Package Name: 10Gb_PTM Package Version: 1.10 ::: Firmware Version: 1.10 BCM82328 ucode Version: 0015 BCM82780 ucode Version: 0028 CPLD ucode Version: 03 [OK] [CMD] If the module console displays C characters instead of. characters, return to step 15 to restart the Xmodem transfer. 17. Press Ctrl + Shift + _. The following message appears: Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > 18. Enter d. 19. To update the firmware on any other pass-thru modules installed in this enclosure, begin at step Firmware updates
13 Command line Command line overview The Onboard Administrator CLI can be used to access the CLI for 10GbE Pass-Thru Module II to execute the Management commands and perform operations on the 10GbE Pass-thru Module II. The CLI user must provide a valid username and password to log in to 10GbE Pass-Thru Module II. The CLI is available for both local user accounts and LDAP users. Two-factor authentication is not available for the CLI. 10GbE Pass-Thru Module II serial port speed is fixed at , HW, 8, 1. For more information about the Command Line Interface, see the Onboard Administrator Command Line Interface User Guide. Command line 13
14 Commands General commands CLS HELP Description Use this command to clear the screen of a terminal emulator. Syntax HELP <command> Description If you supply a command, the usage and help text for the command appears. If no parameter is given, usage and help text for all commands appears. Permissions Administrator Operator User HISTORY Description If you supply a parameter, the expanded documentation for the command appears. If no parameter is given, expanded documentation for all commands appears. INTERFACE Syntax interface enable {all lane#} [#lanes] interface disable {all lane# [#lanes]} interface status {all lane#} Where: enable disable Enable the specified lanes as a single interface. Disable the single interface specified by the lanes. Table Continued 14 Commands
15 status all lane# If a lane# is specified, output status for the specified lane and all lanes in the same enabled interface. If no lane# is specified, output status of all lanes. All lanes are to be operated upon. The first lane of the interface. Valid values are 1 to 16. Description Use this command to configure or query an interface. NOTE: Interface disable and enable commands are destructive commands LOG Syntax log show <clear persistent> log clear log level <{critical error warning info-high info-medium info-low trace debug}> Description Use this command to configure, list, or clear the activity log. The activity log is a circular buffer of messages maintained on the ICM. The severity level of the logs can be queried or configured. The log can be output to the user or cleared. Example output log show 19.0: :master_r: 129:INFO: MR: cached sequence = : :master_r: 514:INFO: MR: wrote entry 20, sequence : :thames_s: 141:INFO: Server Lane 1: Mapped to Interface : :thames_s: 141:INFO: Server Lane 2: Mapped to Interface : :thames_s: 141:INFO: Server Lane 3: Mapped to Interface : :thames_s: 141:INFO: Server Lane 4: Mapped to Interface : :thames_s: 141:INFO: Server Lane 5: Mapped to Interface : :thames_s: 141:INFO: Server Lane 6: Mapped to Interface : :thames_s: 141:INFO: Server Lane 7: Mapped to Interface : :thames_s: 141:INFO: Server Lane 8: Mapped to Interface : :thames_s: 141:INFO: Server Lane 9: Mapped to Interface : :thames_s: 141:INFO: Server Lane 10: Mapped to Interface : :thames_s: 141:INFO: Server Lane 11: Mapped to Interface : :thames_s: 141:INFO: Server Lane 12: Mapped to Interface : :thames_s: 141:INFO: Server Lane 13: Mapped to Interface : :thames_s: 141:INFO: Server Lane 14: Mapped to Interface 14 SUPPORT Syntax support <{off on full dump}>> Commands 15
16 VERSION LED Description Use this command to query the current support level or to change the current support level. Without a parameter, it will output the current level. With a parameter, it will set the new support level to the value of the parameter. Syntax Version <command> Description Use this command to output the current version information. The information includes the type of module, copyright, package info (name, version, and build time), and component versions (firmware, PHY ucode, and CPLD ucode. It has no options or error return messages Example output [CMD] version show [CMD] version HPE 1/10Gb Pass-thru Module (10GbE-PT) Management Processor (c) Copyright 2019 Hewlett Packard Enterprise Development LP All rights reserved Package Name: 10Gb_PTM Package Version: 1.10 Package Build Time: 2019/01/11 12:07:57 Firmware Version: 1.10 BCM82328 ucode Version: 0015 BCM82780 ucode Version: 0028 CPLD ucode Version: 03 Syntax PACKAGE led status all led status number Description Use this command to see the status of the LEDs. Syntax XMODEM {to transfer the package} package validate {to validate the package} package apply{to apply the package to the Alternate Flash Banks and to switch the Primary Flash Banks with the Alternate Flash Blanks. package activate <clear> {to activate the new image} package alternate {to activate the image on the Alternate Flash Bank} 16 Commands
17 RESET SERVER XMODEM Description Use this command to perform firmware updates. Syntax reset <clear {all config phys}> Description Use this command to reset the firmware. Syntax server <enable disable status> server Description Use this command to configure/query an interface for a specific server. Syntax xmodem Description Receive firmware using xmodem. Commands 17
18 Troubleshooting No traffic flow with link up and LED on Symptom There is no traffic flow with link up and the LED is on. Verify the VLAN configuration on the ToR switch port and sever interface. Health status LED flashing amber Symptom The health status LED on the front of the module is flashing amber. There is a fault condition. Press the Reset button. Health LED is not on Symptom The health status LED on the front of the module is not on. Solution 1 The pass-thru module is not seated properly. Be sure that the pass-thru module is inserted completely and seated properly. Solution 2 The enclosure is not powered up. 18 Troubleshooting
19 Be sure that the enclosure is powered up and all the power connections are intact. Solution 3 An LED is faulty. Be sure that the pass-thru module is booted. Solution 4 The pass-thru module is faulty. Send the module for repair. Cannot access the pass-thru module serial console interface from Onboard Administrator Symptom Cannot access the module serial console interface from Onboard Administrator. Solution 1 The module is not inserted properly. Pull out the module and reinsert it. Solution 2 The baud rate is incorrect. 1. Correct the settings for the CLI console. At the Onboard Administrator prompt, enter connect interconnect 2. The following message appears: NOTICE: This pass-thru connection to the integrated I/O console is provided for convenience and does not supply additional access control. For security reasons, use the password features of the integrated switch. Troubleshooting 19
20 Connecting to integrated switch 2 at ,N81... Escape character is '<Ctrl>_' (Control + Shift + Underscore) 2. To display the pass-thru module console, press Enter. 3. Press Ctrl + Shift + _. The following message appears: Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > 4. Enter C. The following message appears: Change settings for: L)ocal Session, R)emote Port [I/O Bay 2], E)xit 5. Enter R. The following message appears: Settings: B)audrate; flow control: N)one H)ardware S)oftware; E)xit > 6. Enter B. The following message appears: Baud: A)1200 B)2400 C)4800 D)9600 F)19200 G)38400 H)57600 I)115200; E)xit > 7. Enter I. The following message appears: Escape character is '<Ctrl>_' (Control + Shift + Underscore) 8. Press Ctrl + Shift + _. The following message appears: Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > 9. Enter C. The following message appears: Change settings for: L)ocal Session, R)emote Port [I/O Bay 2], E)xit 10. Enter R. The following message appears: Settings: B)audrate; flow control: N)one H)ardware S)oftware; E)xit > Connected to integrated switch 2 at ,N81. Escape character is '<Ctrl>_' (Control + Shift + Underscore) 11. Enter H. The following message appears: Connected to integrated switch 2 at ,N81. Escape character is '<Ctrl>_' (Control + Shift + Underscore) 12. At the 10GbE Pass-Thru [CMD] prompt, enter version. The following message appears: [CMD] version HPE 1/10Gb Pass-thru Module (10GbE-PT) Management Processor (c) Copyright 2017 Hewlett Packard Enterprise Development LP All rights reserved Package Name: 10Gb_PTM Package Version: 1.00 Package Build Time: 2016/12/14 3:39:23 Firmware Version: 1.00 BCM82328 ucode Version: 0010 BCM82780 ucode Version: 0028 CPLD ucode Version: 02 [OK] [CMD] 20 Troubleshooting
21 Solution 3 More than one person is connected to the module console from Onboard Administrator. Use the Onboard Administrator CLI show interconnect sessions command to check for active sessions. If an interconnect session is active, use the clear interconnect session command to terminate active sessions on the module. PTM II console not working properly after sending BREAK from OA Symptom PTM II console not working properly after sending BREAK from OA The pass-through module is timed out because it did not receive the firmware file. Sending BREAK signal from OA to PTM II console by typing <Ctrl>_ (Control + Shift + Underscore) + B will make PTM II console work incorrectly. Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > B Sending BREAK... The BREAK signal is not used and supported in PTM II console. It is recommended not to use BREAK. To recover PTM II console from issue state, reset the module using the reset command or by performing a power cycle. No link LED appears, even after plugging the cable into the SFP+module Symptom No link LED appears, even after plugging the cable into the SFP+ module. Solution 1 If the SFP+ module used is "1G SFP SX". Troubleshooting 21
22 Force the link partner (Switch port) to 1G. Solution 2 The cable is not plugged in properly. Ensure that it is plugged in and seated properly at both ends. Ensure that the connector type is the same on both ends for LED to blink. Solution 3 The cable or connector heads are faulty. Replace the cable with another tested cable. Solution 4 The SFP+ module on the pass-thru module or LED is faulty. Examine and replace the cable. If no link LED displays, determine if the port is transferring data. 1. If yes, the LED is faulty. 2. If no, the SFP+ module might be faulty. Call a service representative. Solution 5 The pass-thru module uplink and downlink connections must be up before the LED illuminates. 22 Troubleshooting
23 Verify the uplink and downlink connections. Verify the output of CMD] interface status all. Verify server status [server number] for the server that is not linking up. The download times out after starting to download the firmware file Symptom The download fails after starting to download the firmware file. The firmware file is not the correct file or is corrupt. The location of the file is not reachable. Obtain the latest firmware file that is specified for this pass-thru module. Verify that the FTP location is reachable. Sync error in log Symptom The following error appears: ":xmodem.c: 331:ERRO: Sync error". The pass-through module is timed out because it did not receive the firmware file. If the error is in the log messages, refer to The download times out after starting to download the firmware file. Verify the downloadable firmware package and then restart the download process. Junk characters appear before PTM II CLI Prompt while connecting the console the first time after the module is powered on Symptom While connecting PTM II console the first time after the module is powered on, a few junk characters appears (shown below) before CLI prompt. This is due to baud rate change between OA and PTM II. Troubleshooting 23
24 Press Enter to get the command [CMD] prompt. The following message appears: NOTICE: This pass-thru connection to the integrated I/O console is provided for convenience and does not supply additional access control. For security reasons, use the password features of the integrated switch. Connecting to integrated switch 2 at ,N81... Escape character is '<Ctrl>_' (Control + Shift + Underscore) Press [Enter] to display the switch console: Bj 24 Troubleshooting
25 Websites General websites Hewlett Packard Enterprise Information Library Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix Storage white papers and analyst reports For additional websites, see Support and other resources. Websites 25
26 Support and other resources Accessing Hewlett Packard Enterprise Support For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website: To access documentation and support services, go to the Hewlett Packard Enterprise Support Center website: Information to collect Technical support registration number (if applicable) Product name, model or version, and serial number Operating system name and version Firmware version Error messages Product-specific reports and logs Add-on products or components Third-party products or components Accessing updates Some software products provide a mechanism for accessing software updates through the product interface. Review your product documentation to identify the recommended software update method. To download product updates: Hewlett Packard Enterprise Support Center Hewlett Packard Enterprise Support Center: Software downloads Software Depot To subscribe to enewsletters and alerts: To view and update your entitlements, and to link your contracts and warranties with your profile, go to the Hewlett Packard Enterprise Support Center More Information on Access to Support Materials page: 26 Support and other resources
27 IMPORTANT: Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HPE Passport set up with relevant entitlements. Customer self repair Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your Hewlett Packard Enterprise authorized service provider will determine whether a repair can be accomplished by CSR. For more information about CSR, contact your local service provider or go to the CSR website: Remote support Remote support is available with supported devices as part of your warranty or contractual support agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event notifications to Hewlett Packard Enterprise, which will initiate a fast and accurate resolution based on your product's service level. Hewlett Packard Enterprise strongly recommends that you register your device for remote support. If your product includes additional remote support details, use search to locate that information. Remote support and Proactive Care information HPE Get Connected HPE Proactive Care services HPE Proactive Care service: Supported products list HPE Proactive Care advanced service: Supported products list Proactive Care customer information Proactive Care central Proactive Care service activation Warranty information To view the warranty for your product, see the Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products document, available at the Hewlett Packard Enterprise Support Center: Additional warranty information HPE ProLiant and x86 Servers and Options HPE Enterprise Servers Support and other resources 27
28 HPE Storage Products HPE Networking Products Regulatory information To view the regulatory information for your product, view the Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise Support Center: Additional regulatory information Hewlett Packard Enterprise is committed to providing our customers with information about the chemical substances in our products as needed to comply with legal requirements such as REACH (Regulation EC No 1907/2006 of the European Parliament and the Council). A chemical information report for this product can be found at: For Hewlett Packard Enterprise product environmental and safety information and compliance data, including RoHS and REACH, see: For Hewlett Packard Enterprise environmental information, including company programs, product recycling, and energy efficiency, see: Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page. 28 Support and other resources
29 Acronyms Acronyms and abbreviations CPLD Complex Programmable Logic Device. i2c Inter-Integrated circuit LDAP Lightweight Directory Access Protocol SSH Secure Shell TFTP Trivial File Transfer Protocol ToR Top of rack UID unit identification Acronyms 29
HPE 3PAR OS MU2 Patch 53 Release Notes
HPE 3PAR OS 3.2.2 MU2 Patch 53 Release Notes Abstract This release notes document is for Patch 53 and intended for HPE 3PAR Operating System Software 3.2.2.390 (MU2). Part Number: QL226-99481 Published:
More informationHPE StoreVirtual 3200 Application Aware Snapshot Manager User Guide
HPE StoreVirtual 3200 Application Aware Snapshot Manager User Guide Abstract The StoreVirtual Application Aware Snapshot Manager simplifies the tasks of managing credentials and creating snapshots for
More informationIntegrated Smart Update Tools for Windows and Linux User Guide
Integrated Smart Update Tools for Windows and Linux User Guide Version 2.2.0 Abstract This document describes how to use Integrated Smart Update Tools to update firmware and operating system drivers on
More informationHPE StoreVirtual OS Update Guide
HPE StoreVirtual OS Update Guide Abstract This guide is intended for system administrators who are responsible for updating to the latest versions of software for StoreVirtual storage. Part Number: 865551-002
More informationHPE 3PAR OS GA Patch 20 Release Notes
HPE 3PAR OS 3.3.1 GA Patch 20 Release Notes Abstract This release notes document is for Patch 20 and intended for HPE 3PAR Operating System Software OS-3.3.1.215-GA. Part Number: QL226-99808 Published:
More informationHPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide
HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide Abstract This document explains how to install and use the HPE StoreEver MSL6480 Tape Library CLI utility, which provides a non-graphical
More information10GbE Pass-Thru Module User Guide
10GbE Pass-Thru Module User Guide Part Number 573130-002 December 2010 (Second Edition) Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change
More informationHPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide
HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide Abstract This guide contains instructions for installing and deploying the StoreVirtual Application Aware Snapshot Manager to
More informationRelease Notes PK.1.34
Release Notes PK.1.34 Abstract This document contains information for the PK.1.34 release. Part Number: 5200-3848 Published: April 2017 Edition: 1 2017, Hewlett Packard Enterprise Development LP Notices
More informationHewlett Packard Enterprise. HPE OmniStack for vsphere Upgrade Guide
Hewlett Packard Enterprise HPE OmniStack for vsphere Upgrade Guide Part number: P00126-001 Published: September 2017 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein
More informationHPE ProLiant Updates Catalog (v ) User Guide
HPE ProLiant Updates Catalog (v 2016.12.0) User Guide Abstract This guide describes the procedures and prerequisites for installing and using the HPE ProLiant Updates Catalog, which provides firmware and
More informationAruba 8400X Introduction to the Web UI for ArubaOS-CX 10.00
Aruba 8400X Introduction to the Web UI for ArubaOS-CX 10.00 Part Number: 5200-4335 Published: November 2017 Edition: 1 Copyright 2017 Hewlett Packard Enterprise Development LP Notices The information contained
More informationHPE PSR300-12A & PSR300-12D1
HPE PSR300-12A & PSR300-12D1 Power Supplies User Guide 5998-1604s Part number: 5998-1604s Document version: 6PW103-20160405 Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information
More informationHPE StoreOnce Optional Hardware Installation and Configuration Guide
HPE StoreOnce Optional Hardware Installation and Configuration Guide Abstract This document is for StoreOnce System administrators responsible for installing and licensing StoreOnce Optional Hardware.
More informationHP Moonshot-45XGc Switch User and Maintenance Guide
HP Moonshot-45XGc Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identification, setup,
More informationHP Moonshot Switch User and Maintenance Guide
HP Moonshot Switch User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots switches. This guide provides identification, setup, installation,
More informationHPE StoreOnce 3.16.x Software Upgrade Guide
HPE StoreOnce 3.16.x Software Upgrade Guide Abstract This document describes the process for upgrading to StoreOnce 3.16.x from StoreOnce 3.14.x and later software. This document is intended for system
More informationHP BladeSystem c-class Enclosure Troubleshooting Guide
HP BladeSystem c-class Enclosure Troubleshooting Guide Part Number 460224-002 July 2009 (Second Edition) Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. The information contained herein
More informationMarvell BIOS Utility User Guide
Marvell BIOS Utility User Guide for HPE MicroServer Gen10 Abstract This user guide provides information on how to use the embedded Marvell BIOS Utility to create and manage RAID virtual disks and arrays.
More informationHPE BladeSystem Onboard Administrator Release Notes 4.70
HPE BladeSystem Onboard Administrator Release Notes 4.70 Abstract This document provides Onboard Administrator release information for version 4.70. This document supersedes the information in the documentation
More informationHPE BladeSystem c3000 Enclosure Quick Setup Instructions
HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the
More informationHPE Synergy 40Gb F8 Switch Module
HPE Synergy 40Gb F8 Switch Module DHCP Configuration Abstract This document is intended for the person who configures HPE Synergy 40Gb F8 Switch Modules. 20140325a March 2017 Edition: 1 Copyright 2016,
More informationHP 10GbE Pass-Thru Module
Overview The is designed for c-class BladeSystem and HP Integrity Superdome 2 customers requiring a nonblocking, one -to-one connection between each server and the network. The pass-thru module provides
More informationHP 6125 Blade Switch Series
HP 6125 Blade Switch Series Installation Guide Part number: 5998-3151 Document version: 6W100-20120907 Legal and notice information Copyright 2012 Hewlett-Packard Development Company, L.P. No part of this
More informationHPE 5510HI_5130HI-POE-V146 Release Notes
HPE 5510HI_5130HI-POE-V146 Notes The information in this document is subject to change without notice. Copyright 2015,2016 Hewlett Packard Enterprise Development LP Contents Version information 1 Version
More informationHPE Synergy Configuration and Compatibility Guide
HPE Synergy Configuration and Compatibility Guide Abstract This guide describes HPE Synergy hardware configuration options and compatibility. Hewlett Packard Enterprise assumes you are qualified in the
More informationHPE 3PAR StoreServ 7000 Storage Service and Upgrade Guide Customer Edition
HPE 3PAR StoreServ 7000 Storage Service and Upgrade Guide Customer Edition HPE 3PAR OS 3.2.2 and 3.3.1 HPE SP 4.x and 5.x Abstract This Hewlett Packard Enterprise (HPE) guide provides information and instructions
More informationHPE FlexNetwork MSR Router Series
HPE FlexNetwork MSR Router Series Comware 7 OAA Configuration Guides Part number: 5998-8789 Software version: CMW710-E0407 Document version: 6W100-20160526 Copyright 2016 Hewlett Packard Enterprise Development
More informationQuickSpecs. HPE 10GbE Pass-Thru Module. Overview. What's New. At A Glance
Overview The is designed for c-class BladeSystem and HPE Integrity Superdome 2 customers requiring a nonblocking, one -to-one connection between each server and the network. The pass-thru module provides
More informationHP Virtual Connect for c-class BladeSystem Setup and Installation Guide
HP Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.01 Abstract This document contains setup, installation, and configuration information for HP Virtual Connect. This document
More informationHP BladeSystem c-class Virtual Connect Support Utility Version Release Notes
HP BladeSystem c-class Virtual Connect Support Utility Version 1.9.1 Release Notes Abstract This document provides release information for the HP BladeSystem c-class Virtual Connect Support Utility Version
More informationStoreOnce 6500 (88TB) System Capacity Expansion Guide
StoreOnce 6500 (88TB) System Capacity Expansion Guide Abstract This document explains how to install the StoreOnce 6500 System Capacity Expansion Kit, apply the new license, and add the new storage to
More informationHPE Intelligent Management Center
HPE Intelligent Management Center MySQL 5.5 Installation and Configuration Guide (for Linux) Abstract This document provides installation and configuration information for MySQL. It includes the procedures
More informationHPE ilo Federation User Guide for ilo 5
HPE ilo Federation User Guide for ilo 5 Abstract This guide explains how to configure and use the HPE ilo Federation features. It is intended for system administrators, Hewlett Packard Enterprise representatives,
More informationInstalling a Network Module
3 CHAPTER This chapter describes how to install and connect a network module. Overview, page 3-1 in the Switch, page 3-4 SFP and SFP+ Modules, page 3-7 Finding the Network Module Serial Number, page 3-9
More informationUEFI Settings Quick Reference Guide for HPE ProLiant Gen10 Servers and HPE Synergy
UEFI Settings Quick Reference Guide for HPE ProLiant Gen10 Servers and HPE Synergy Abstract This guide lists and describes the UEFI System Utilities menu options. Information is listed alphabetically for
More informationHPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60
HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 Abstract This document contains setup, installation, and configuration information for HPE Virtual Connect. This document
More informationHPE 3PAR OS MU1 Patch 19 Release Notes
HPE 3PAR OS 3.3.1 MU1 Patch 19 Release Notes Abstract This release notes document describes the HPE 3PAR OS 3.3.1 MU1 Patch 19. This patch must be applied to all systems running 3.3.1 MU1 when using or
More informationHP 6127XLG Blade Switch Series
HP 6127XLG Blade Switch Series Installation Guide Part number: 797699-001 Document version: 5W100-20150602 Legal and notice information Copyright 2015 Hewlett-Packard Development Company, L.P. No part
More informationInstalling and Managing the Switch
CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationHPE ProLiant Gen9 Troubleshooting Guide
HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,
More informationHPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes
HPE BladeSystem c-class Virtual Connect Support Utility Version 1.12.0 Release Notes Abstract This document provides release information for the HPE BladeSystem c-class Virtual Connect Support Utility
More informationHPE Insight Management WBEM Providers for Microsoft Windows Eventlog Messages
E Insight Management WBEM s 0.60 for Microsoft log Messages Part Number: 866479-00 Published: October 06 Edition: Copyright 00, 06 Hewlett Packard Enterprise Development LP The information contained herein
More informationHP Virtual Connect for c-class BladeSystem Version 2.10 User Guide
HP Virtual Connect for c-class BladeSystem Version 2.10 User Guide Part Number 519212-001 April 2009 (First Edition) Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein
More informationInstalling a Network Module
Network Module Overview, page in the Switch, page 7 Removing a Network Module, page 3 SFP and SFP+ Modules, page 4 Finding the Network Module Serial Number, page 6 Network Module Overview Network Module
More informationTroubleshooting Initial Startup Problems
Your Cisco ASR 1000 Series Router went through extensive testing before leaving the factory. However, if you encounter problems starting the router, use the information in this chapter to help isolate
More informationHPE ProLiant WS460c Gen9 Graphics Server Blade User Guide
HPE ProLiant WS460c Gen9 Graphics Server Blade User Guide Abstract This guide provides operation information for the HPE ProLiant WS460c Graphics Server Blade. This guide is for technicians that install,
More informationHPE LSWM124XGT2Q Interface Module (JH182A) User Guide
HPE LSWM124XGT2Q Interface Module (JH182A) User Guide Part number: 5998-7152t Introduction Product HPE description Alias JH182A HPE 5930 24-port 10GBASE-T and 2-port QSFP+ with MACsec Module LSWM124X GT2Q
More informationHPE Apollo Platform Manager User Guide
HPE Apollo Platform Manager User Guide Abstract This guide provides installation and operation guidance for the HPE Apollo Platform Manager. This guide is for the person who installs, administers, and
More informationHPE Integrity Superdome X and Superdome 2 Onboard Administrator Guide for Users
HPE Integrity Superdome X and Superdome 2 Onboard Administrator Guide for Users Abstract This document describes the Onboard Administrator for the HPE Integrity Superdome X and Superdome 2 enclosures.
More informationHPE StoreOnce 5100 System Capacity Upgrade Guide
HPE StoreOnce 5100 System Capacity Upgrade Guide Abstract This guide is for StoreOnce Administrators; it describes how to install the HPE StoreOnce 5100 System Capacity Upgrade kit, and how to license
More informationSCv3000 and SCv3020 Storage System. Owner s Manual
SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationHP Virtual Connect for c-class BladeSystem Version 3.01 User Guide
HP Virtual Connect for c-class BladeSystem Version 3.01 User Guide Part Number 621011-001 June 2010 (First Edition) Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein
More informationDell SCv300 and SCv320 Expansion Enclosure Owner's Manual
Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that
More informationHP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions
HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions About this document For the latest documentation, go to http:// www.hp.com/support/manuals, and select your product. The information
More informationInstall the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1
Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1 Install the Cisco SNS 3415 or 3495 Appliance in a Rack, page
More informationHP Advanced Services v2 zl Module Installation Guide
HP Advanced Services v2 zl Module Installation Guide Abstract This document describes how to install and initially configure the Advanced Services v2 zl Module (J9857A and J9858A). This product is hereafter
More informationCatalyst 6500 Series Wireless LAN Services Module Installation and Verification Note
Catalyst 00 Series Wireless LAN Services Module Installation and Verification Product number: WS-SVC-WLAN--K This document provides installation procedures for the Catalyst 00 series Wireless LAN Services
More informationCommand-Line Interfaces
CHAPTER 2 This chapter describes the CLIs you use to configure the Catalyst 4500 series switch. This chapter includes the following major sections: Accessing the Switch CLI, page 2-1 Performing Command-Line
More informationUpgrading R/Evolution Storage Systems
Upgrading R/Evolution Storage Systems This guide describes considerations and procedures for upgrading the following R/Evolution storage systems: 2000 Series to 2002 Series storage systems 2000 Series
More informationEnclosure rear components
HP BladeSystem Insight Display components Item Description Function 1 Insight Display screen Displays Main Menu error messages and instructions 2 Left arrow button Moves the menu or navigation bar selection
More informationTable of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...
Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...
More informationSecurity Acceleration Module
Security Acceleration Module Getting Started Guide 15 December 2013 Classification: [Protected] P/N: 705386 2013 Check Point Software Technologies Ltd. All rights reserved. This product and related documentation
More informationS Release Notes
S.15.09.0029 Release Notes Abstract This document contains supplemental information for the S.15.09.0029 release. Part Number: 5200-3850 Published: April 2017 Edition: 1 2017 Hewlett Packard Enterprise
More informationTroubleshooting CHAPTER
CHAPTER 5 If your system has problems during start up or operation, use the information in this chapter to help isolate the cause. Problems with the initial startup are often caused by a switching module
More informationHPE ConvergedSystem 500 for SAP HANA Scale-up Configurations
HPE ConvergedSystem 500 for SAP HANA Scale-up Configurations Administration, Operations, and Troubleshooting Guide Abstract This document is intended to assist SAP solution architects, SAP database and
More informationDell SCv3000 and SCv3020 Storage System Owner s Manual
Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationHP Smart Update Tools User Guide
HP Smart Update Tools User Guide Version 1.0.1 Abstract This document describes how to use HP Smart Update Tools (HP SUT) to update firmware and operating system drivers on HP ProLiant servers. This document
More informationDell SC7020 and SC7020F Storage Systems Owner s Manual
Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationQuickSpecs. HPE Synergy 10Gb Pass-Thru Module. Overview. At A Glance
Overview The is designed for the HPE Synergy 12000 Frame for customers requiring a non-blocking, one -to-one connection between each Synergy Compute Module and the network. The pass-thru module provides
More informationHPE Intelligent Power Distribution Unit Installation Instructions
HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for
More informationHPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide
HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated
More informationHPE OneView 3.1 Support Matrix
HPE OneView 3.1 Support Matrix Abstract This document lists the hardware, firmware, and software requirements for installing and using HPE OneView on a virtual machine host. Part Number: 5200-1774e Published:
More informationInstallation Notes for the Catalyst 3750-X and 3560-X Network Modules
Installation Notes for the Catalyst 3750-X and 3560-X Network Modules Published: October, 2011 This note provides the installation instructions for the Catalyst 3750-X and 3560-X network modules. Translations
More informationNETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL
NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL Contents Chapter 1 Introduction... 1 Chapter 2 Mounting the Switch... 2 2.1 Environmental Requirements... 2 2.2 Installation Instruction... 2 2.3 Connect
More informationHPE Integrity BL860c i2, BL870c i2 & BL 890c i2 Server Blade Installation Guide
HPE Integrity BL860c i2, BL870c i2 & BL 890c i2 Server Blade Installation Guide Abstract This document contains specific information that is intended for users of this Hewlett Packard Enterprise product.
More informationDell SC5020 and SC5020F Storage System Owner s Manual
Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationHP ProLiant Moonshot Server User and Maintenance Guide
HP ProLiant Moonshot Server User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots cartridges. This guide describes identification and
More informationInstalling a Network Module
Network Modules Overview, page 1 in the Switch, page 2 Removing a Network Module, page 10 SFP and SFP+ Modules, page 11 Finding the Network Module Serial Number, page 13 Network Modules Overview The Cisco
More informationHPE LTO Ultrium 30750, 15000, 6250, 3000, 1760, and 920 External Tape Drives Start Here
HPE LTO Ultrium 30750, 15000, 6250, 3000, 1760, and 920 External Tape Drives Start Here Abstract This document describes how to connect a StoreEver LTO Ultrium SAS external tape drive to an external high-density
More informationInstall your TPS 440T and 2200T security devices
Install your TPS 440T and 2200T security devices This information provides detailed installation instructions for your Threat Protection System (TPS) 440T and 2200T security devices. Before you begin Before
More informationInstalling the Cisco Unified Videoconferencing 3545 MCU
CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)
More informationNext Generation Firewall
Next Generation Firewall Hardware Guide Models 110, 115 Revision A Contents Introduction on page 2 Find product documentation on page 2 Model N110 features on page 3 Model N115 features on page 5 Precautions
More informationNo Service Password-Recovery
No Service Password-Recovery Last Updated: January 18, 2012 The No Service Password-Recovery feature is a security enhancement that prevents anyone with console access from accessing the router configuration
More informationHP Eight-Port SAS/SATA RAID Host Bus Adapter
HP Eight-Port SAS/SATA RAID Host Bus Adapter Installation Guide June 2006 (Second edition) Part Number 377610-002 Legal notices Copyright 2005, 2006 Hewlett-packard Development Company, L.P. The information
More informationHPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide
HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide Abstract This guide is for HPE StoreOnce System Administrators. It assumes that the user has followed the instructions
More informationLenovo Flex System SI Gb System Interconnect Module. Release Notes. for Networking OS 8.2
Lenovo Flex System SI4091 10Gb System Interconnect Module Release Notes for Networking OS 8.2 Note: Before using this information and the product it supports, read the general information in the Safety
More informationLenovo RackSwitch G8272. Release Notes. For Networking OS 8.2
Lenovo RackSwitch G8272 Release Notes For Networking OS 8.2 Note: Before using this information and the product it supports, read the general information in the Safety information and Environmental Notices
More informationHPE Altoline XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline XG 6QSFP+ x86 ONIE AC Back-to-Front Switch
Overview Models HPE Altoline 6920 48XG 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline 6920 48XG 6QSFP+ x86 ONIE AC Back-to-Front Switch JL167A JL168A Key features High 10GbE port density and low
More informationNETWORKS DATA CENTER SWITCHES USER MANUAL
NETWORKS DATA CENTER SWITCHES USER MANUAL Contents Chapter 1 Introduction... 1 Chapter 2 Mounting the Switch... 2 2.1 Environmental Requirements... 2.2 Rack-Mount Installation... 2.3 Install the Switch
More informationCommand-Line Interfaces
CHAPTER 2 This chapter describes the CLIs you use to configure the Catalyst 4500 series switch. This chapter includes the following major sections: Accessing the Switch CLI, page 2-2 Performing Command-Line
More informationHP ProLiant BL280c G6 Server Blade User Guide
HP ProLiant BL280c G6 Server Blade User Guide Abstract This document describes installation, administration, and troubleshooting for this server blade. This document is for the person who installs, administers,
More informationAdministrator's Guide. HP BladeSystem PC Blade Enclosure Integrated Administrator v4.40
Administrator's Guide HP BladeSystem PC Blade Enclosure Integrated Administrator v4.40 Copyright 2007 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change
More informationQUICK START GUIDE 7000 SERIES DEVICES. 3D7010/7020/7030 (Chassis: CHRY-1U-AC) 3D7115/7125, AMP7150 (Chassis: GERY-1U-4C8S-AC)
Thank you for choosing Sourcefire! Before installing this device, download and follow the instructions in the Sourcefire Support Welcome Kit (https://support.sourcefire.com) to get started with Sourcefire
More informationHPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A)
HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A) Quick Start Guide 5998-7330R The information in this document is subject to change without notice. Copyright 2016 Hewlett Packard Enterprise Development
More informationQLogic iscsi Boot for HP FlexFabric Adapters User Guide
QLogic iscsi Boot for HP FlexFabric Adapters User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in
More informationPower Enclosure Components
Power Enclosure Components HP BladeSystem p-class 1U Power Enclosure Exploded View Figure 1-5 HP BladeSystem p-class 1U power enclosure exploded view Illustrated Parts Catalog 20 HP BladeSystem p-class
More informationHP0-S21. Integrating and Managing HP BladeSystem in the Enterprise. Download Full Version :
HP HP0-S21 Integrating and Managing HP BladeSystem in the Enterprise Download Full Version : http://killexams.com/pass4sure/exam-detail/hp0-s21 Question: 165 You are setting up a new infiniband network
More informationQuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series
Overview Models HPE Altoline 6921 48SFP+ 6QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline 6921 48SFP+ 6QSFP+ x86 ONIE AC Back-to-Front Switch HPE Altoline 6921 48XGT 6QSFP+ x86 ONIE AC Front-to-Back
More information