DOCUMENTATION MECrf TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 24 November 2017

Size: px
Start display at page:

Download "DOCUMENTATION MECrf TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 24 November 2017"

Transcription

1 DOCUMENTATION MECrf TECHNICAL AND APPLICATION DESCRIPTION Author: Peter Hauner Last modification: 24 November Apricum d.o.o. Mažuranićeva 4, Podstrana, Hrvatska Details, modifications and corrections may be subject to change without notice. Apricum gives no warranty for the accuracy of the document. The reproduction, transmission and use of this document or its contents is not permitted without written authority. All rights reserved.

2 1 CONTENTS 1 Contents MECrf Product Description Apricum MECrf Highlights Operational Description Normal Mode Program Button The Function Button Manual Function Factory Reset Application Description ETS Parameters Physical Address Assignment General Main Line (KNX TP) Subline (KNX RF) State of Delivery Technical Data RF Technical Data Dimension Drawing /

3 2 MECrf PRODUCT DESCRIPTION The basic functionality of the media coupling device MECrf is connecting KNX TP (main line) and KNX RF (subline). Main task of the MECrf is filtering the telegram traffic according to the installation place in the hierarchy (individually addressed telegrams, in this document named Physical telegrams) or according to the built in filter tables for group oriented communication (Group telegrams). Filtering of messages can be enabled or disabled. With the MECrf it is possible to address every bus device in the bus system. For RF devices the MECrf can be used as the programming interface via TP. Programming on the TP side from RF side can be suppressed. Number of retransmissions can be reduced. Device oriented messages can be suppressed. The MECrf has no KNX communication objects for itself, supports long messages (up to 201 byte APDU length) and features a configurable Manual function (e.g. transmit all group telegrams) that can be activated by a single button press. In addition, the device switches on filter tables after time out automatically. Another feature to increase the data trough put is the ability to send an immediate acknowledged (IACK on TP side) on an own frame. The device conforms to KNX-AN161 with all options (Filtering, Raw mode) and offers a detailed internal diagnosis by displaying all operational states with six LEDs. The LEDs show the device states like bus state, traffic on bus, errors/faulty messages, busy on the bus, state of the filter table, etc. LED Picture 1: Frontside panel and backside panel description 1 Bus State KNX RF (Subline) 7 Programming 2 Bus State KNX TP (Main line) Part 3 4 Telegram Traffic KNX RF (Subline) Telegram Traffic KNX TP (Main line) / 13 A B RF antenna Function button 5 Physical Address Routing C Program button 6 Group Address Routing D KNX TP connector

4 3 APRICUM MECrf HIGHLIGHTS In combination with the Apricum USB interface UIMtp long messages are made possible (e.g. for energy metering applications). The MECrf favourably replaces a line coupler in a wireless sub network. The Apricum MECrf works without external power supply. Retransmitter function is supported. Picture 2: Connection scheme IACK on own sent out messages (ETS configurable) on TP side. After no IACK response on TP side the MECrf is able to repeat it up to three times. For physically addressed and for group addressed telegrams this can be configured via ETS independently. In case of an IACK response there will be no repetition. The failure mechanism of a negative IACK or BUSY is still maintained hereby. Programmable automatic switch on of the filter table after timeout. For a predefined amount of time (ETS configurable) it is possible to switch off the filter table with pressing a button on the device. So, without reconfiguring the device with the ETS the filter table can be switched off by a button press which is necessary for running fast diagnostics on site. Filtering of messages can temporarily be disabled by pressing the Function button. This eases commissioning and debugging of the system. Without an ETS download a temporary access to other lines is possible. After the timeout an automatic switching the filter table on is implemented (the timeout is configurable in the ETS). This avoids forgetting to reactivate the filter. For networks with a high bus load a high internal amount of communication buffers is suitable. The MECrf is featuring a high internal amount of communication buffers being capable of smoothing peeks in the communication load course. The MECrf s ETS database entries are available for the ETS5. 4 /

5 4 OPERATIONAL DESCRIPTION According either to the factory default settings or the latest parameter settings downloaded from ETS (also other tools) the MECrf operates as it is supposed to. Like a polite device the MECrf s internal functioning contains channel sensing before transmission to determine if the transmission channel is free. Concerning any end user application the duty cycle must be kept below 1%. Please note for commissioning: Do not mount the MECrf on a metal rail or on a metal fastener. Make sure that during operation a minimum distance of 20cm to the human body, conducting surfaces and metal objects is kept. All telegrams are blocked because the filter table is not defined The switch-off time for the Manual Function is 60 min The physical address is NORMAL MODE Number LED Colour Explanation / Range Bus State KNX RF (Subline) Bus State KNX TP (Main line) Telegram Traffic KNX RF (Subline) Telegram Traffic KNX TP (Main line) Physical Address Routing Group Address Routing 7 Programming green Subline OK < off > Subline not connected green green+red Main line OK Manual Function active < off > Main line not connected blinking green Telegram traffic extent indicated by blinking blinking red Transmission error < off > No telegram traffic blinking Telegram traffic extent of routed telegrams, green indicated by blinking blinking red Transmission error < off > No telegram traffic routed green orange Filtering active Block all green+orange Route all < off > Routing of Physical telegrams not the same between main line and subline green Filter table active red green+red < off > red blinking red Block all Route all Routing of Group telegrams not the same between main line and subline Program mode active No RF connection / 13

6 4.2 PROGRAM BUTTON To download the desired physical address or to download a full ETS setting the Program button needs to be pressed. Successive pressing on the Program button will lead to turn on and off the ETS Program Mode. The Programming LED (LED 7) lights up in colour red. 4.3 THE FUNCTION BUTTON The Function button is used for two purposes; either to activate/deactivate the Manual Function or to do a factory reset. It depends on the duration of time this button is pressed MANUAL FUNCTION Picture 3: Side view and Function button Long press ( 3 sec) Pressing the Function button for about 3 seconds turns on and off the Manual Function. When turned to On the LEDs 2,5,6 light with mixed colour and LED 1 lights green. The default function is set by the RF line and the (KNX) line parameters. To configure the Manual Function and set the Fallback time use the ETS parameter tab General. The last downloaded parameter setting and filter table are still available after switching back from Manual Function to Normal Mode. During a physical address download (also full download) the Manual Function is switched off automatically FACTORY RESET Very long press ( 15s) A factory reset is carried out by pressing the Function button for about 15 seconds (LEDs 2,5,6 and LED 1 light with mixed colour). After release, pressing it again for some seconds resets all the parameters to factory default (incl. physical address and since version 1.3 domain address). Subsequently, the LEDs change their status. 6 /

7 5 APPLICATION DESCRIPTION When the coupler receives telegrams (for example during commissioning) that use physical addresses as destination addresses, it compares the physical addresses of the receiver with its own physical address and then decides whether it has to route the telegrams or not. Due to telegrams with group addresses the coupler reacts in accordance with its parameter settings. During normal operation (default setting), the coupler only routes those telegrams whose group addresses have been entered in its filter table. If the coupler routes a telegram and does not receive an acknowledgement, or if a bus device discovers a transmission error, the coupler repeats the telegram on TP side up to three times (depending on the corresponding parameter that is set to the device through the last ETS download). With the parameters Repetitions if errors..., this behaviour can be set separately for both Physical telegrams and Group Telegrams. These parameters should stay with the default setting. 6 ETS PARAMETERS All screen shots in this chapter represent the MECrf database entry in ETS PHYSICAL ADDRESS ASSIGNMENT With the ETS the physical address can be assigned to the device by setting the desired address in the properties window of the ETS. To download the desired physical address and a full ETS setting into the device the Program button C has to be pressed. The Program button puts the device into Program Mode. After starting the download and pressing the Program button the device restarts itself. To commission the device an interface connection (IP, USB) to the KNX bus system is required. The device is supplied with the individual physical address The KNX product database entry (available for ETS5 and higher) can be downloaded from the Apricum website and the KNX Online Catalog. Note: In this document only the term physical address is used. The term physical address means the physical address as well as the individual address. Both terms are used by the KNX organisation interchangeably. Picture 4: Properties window / 13

8 6.2 GENERAL Picture 5: General ETS Text Switch-off time for Manual Function Manual Function Selection [Factory default] 10 min, 1 hour, 4 hours, 8 hours [1 hour] disabled pass all telegrams pass all Physical telegrams pass all Group telegrams [pass all telegrams] Comment After expiry of this time period the Manual Function is switched off automatically. Configuration setting for telegram routing when the Manual Function is activated. 6.3 MAIN LINE (KNX TP) For Group telegrams and Physical telegrams the selection transmit all is intended only for testing purposes. Please do not use for normal operation. If the parameter Send confirmation on own telegrams is set to yes, the MECrf systematically sends an ACK on any own routed telegram. Picture 6: Main line (KNX TP) 8 /

9 ETS Text Telegram routing Group telegrams: Main group 0 13 Group telegrams: Main group Physical telegrams Physical: Repetition if errors on main line Group: Repetition if errors on main line Telegram confirmation on main line Send confirmation on own telegrams Selection [Factory default] Group: filter, Physical: block Group and Physical: filter Group: route, Physical: filter Group and Physical: route configure [Group and Physical: filter] 1. transmit all (not recommended) 2. block 3. filter [filter] 1. transmit all (not recommended) 2. block 3. filter [filter] 1. transmit all (not recommended) 2. block 3. filter [filter] 1. no 2. up to 3 repetitions 3. one repetition [up to 3 repetitions] 1. no 2. up to 3 repetitions 3. one repetition [up to 3 repetitions] 1. if routed 2. always [if routed] 1. yes 2. no [no] Comment - block: no telegrams are routed. - filter: only telegrams entered in the filter table are routed. - route: all telegrams are routed. - configure: the following parameters can be set manually. 1. Group telegrams (with main group 0 13) are routed. 2. Group telegrams (with main group 0 13) are not routed. 3. Group telegrams (with main group 0 13) are routed if they are entered in the filter table. 1. Group telegrams (with main group 14 31) are routed. 2. Group telegrams (with main group 14 31) are not routed. 3. Group telegrams (with main group 14 31) are routed if they are entered in the filter table. 1. All Physical telegrams are routed. 2. Physical telegrams are not routed. 3. Depending on the physical address Physical telegrams are routed. Transmission error (e.g. missing receiver) after sending a Physical telegram on the main line: 1. Physical telegrams are not repeated. 2. Physical telegrams are repeated up to 3 times. 3. Physical telegrams are repeated only once. Transmission error (e.g. missing receiver) after sending a Physical telegram on the main line: 1. Group telegrams are not repeated. 2. Group telegrams are repeated up to 3 times. 3. Group telegrams are repeated only once. 1. Only routed telegrams are confirmed on the main line (own ACK). 2. Each telegram on the subline is confirmed (own ACK). 1. Every telegram on the main line is confirmed with its own ACK (from the media coupler). 2. No confirmation with own ACK / 13

10 6.4 SUBLINE (KNX RF) For Group telegrams and Physical telegrams the selection transmit all is intended only for testing purposes. Please do not use for normal operation. Picture 7: Subline (KNX RF) ETS Text Telegram routing Group telegrams: Main group 0 13 Group telegrams: Main group Physical telegrams Configuration from subline (KNX RF) Selection [Factory default] Group: filter, Physical: block Group and Physical: filter Group: route, Physical: filter Group and Physical: route configure [Group and Physical: filter] 1. transmit all (not recommended) 2. block 3. filter [filter] 1. transmit all (not recommended) 2. block 3. filter [transmit all] 1. transmit all (not recommended) 2. block 3. filter [filter] allow block [allow] Comment - block: no telegrams are routed. - filter: only telegrams entered in the filter table are routed. - route: all telegrams are routed. - configure: the following parameters can be set manually. 1. Group telegrams (with main group 0 13) are routed. 2. Group telegrams (with main group 0 13) are not routed. 3. Group telegrams (with main group 0 13) are routed if they are entered in the filter table. 1. Group telegrams (with main group 14 31) are routed. 2. Group telegrams (with main group 14 31) are not routed. 3. Group telegrams (with main group 14 31) are routed if they are entered in the filter table. 1. All Physical telegrams are routed. 2. Physical telegrams are not routed. 3. Depending on the physical address Physical telegrams are routed. If blocked, then the ETS download to the MECrf can only occur via KNX TP (main line). 10 /

11 7 STATE OF DELIVERY The MECrf is delivered with the following default factory settings: General Product Order Number Application(s) ETS Name TP RF Media Coupler MECrf RF Coupler TP RF Coupler MECrf Physical address KNX TP (KNX TP Main line to RF Subline) Group telegrams (main group 0 13) Group telegrams (main group 14 31) Physical telegrams Physical: Repetition if errors on KNX TP Group: Repetition if errors on KNX TP Telegram confirmations on KNX TP Send confirmation on own telegrams filter filter filter up to 3 repetitions up to 3 repetitions if routed no KNX RF (KNX RF Subline to KNX TP Main line) Group telegrams (main group 0 13) Group telegrams (main group 14 31) Physical telegrams Configuration from KNX TP filter filter filter enabled / 13

12 8 TECHNICAL DATA Warning: Do not connect to 230V Marking/Design Current consumption Connection Display elements Control elements Protection type Pollution degree Protection class Overvoltage category Approbation CE Marking Power supply Housing colour Dimensions Weight Device temperature Ambient humidity RF performance MECrf < 10 ma KNX TP line: KNX TP connector (red/black), screwless for single-core cable Ø mm LED Bus State LED Telegram Traffic LED PA/GA LED Programming Function button, Program button IP20 according to IEC according to IEC III according to IEC61140 II according to IEC KNX-certified according to ISO/IEC According to low voltage and EMC guidelines Compliance with EN50428, EN50581, EN and EN62479 Safety extra low voltage, 21 30V DC (SELV) Transparent plastic PA66 housing H = 40 mm, W = 40 mm, D = 9 mm 14 g Working temperature: C Storage temperature: C 5 93 %, non-condensing RF antenna RF range: up to 100 m 12 /

13 9 RF TECHNICAL DATA Frequency range KNX RF KNX Ready (RF+) Modulation Rx radiated sensitivity Tx radiated power KNX Ready RF1.R KNX Multi Bibat max. APDU length MHz + / Khz FSK -100 dbm KNX specification (-95 dbm) +10 dbm KNX specification (0 dbm) Yes (with Listen Before Talk medium access) Hardware is ready for KNX Multi Not supported 201 bytes Mask Version DIMENSION DRAWING All dimensions shown here are specified in mm. Picture 8: Dimension drawing / 13

KNX USB INTERFACE UIMtp

KNX USB INTERFACE UIMtp KNX USB INTERFACE UIMtp TECHNICAL AND APPLICATION DESCRIPTION Author: Peter Hauner Last modification: 13 November 2017 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details, modifications

More information

USB RF INTERFACE UIMrf

USB RF INTERFACE UIMrf USB RF INTERFACE UIMrf TECHNICAL AND APPLICATION DESCRIPTION Author: Peter Hauner Last modification: 13 November 2017 2001-2017 TAPKO Technologies GmbH Im Gewerbepark A15, 93059 Regensburg, Germany Details,

More information

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017 DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION Author: Peter Hauner Last modification: 8 September 2017 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details, modifications

More information

Contents 1. Summary

Contents 1. Summary Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R KNX IP Router User manual-ver.1 BNIPR-00/00.1 KNX/EIB Intelligent Installation Systems Contents 1. Summary------------------------------------------------------------------------------------------------------------------------------

More information

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification:

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification: DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION Authors: Manouchehr Ghahramanian Golzar, Peter Hauner Last Modification: 2017-03-02 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska

More information

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli)

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli) Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli) EAE Technology www.eaetechnology.com CONTENTS 1 General...3 1.1 Communication objects...4 1.2 IPR100 as programming interface...4 1.3 Tunnelling...4

More information

KSR-01IP KNX IP Router Instruction manual

KSR-01IP KNX IP Router Instruction manual KSR-01IP KNX IP Router Instruction manual KSR-01IP Instruction Manual Content 1.Product Description... 1 1.1 Front Panel... 1 1.2 LED Indication... 2 1.3 Commissioning... 2 1.4 Feature Summary... 3 2.KNXnet/IP...

More information

USER MANUAL CU-DIN IPRT KNX EC MA

USER MANUAL CU-DIN IPRT KNX EC MA CU-DIN IPRT KNX EC10430527 MA00653502 Table of contents 1 Description...3 2 Safety instructions...4 3 Product Funtion...5 3.1 Communication objects... 5 3.2 CU-DIN IPRT KNX as programming interface...

More information

Installer Manual Line/Field coupler KNX standard, installation on DIN rail (60715 TH35)

Installer Manual Line/Field coupler KNX standard, installation on DIN rail (60715 TH35) Installer Manual Line/Field coupler KNX standard, installation on DIN rail (60715 TH35) Contents 1. Product description 4 2. KNX topology 4 3. Device frontend 5 3.1 Installation example 6 4. Operational

More information

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29 Linienkoppler S KNX Line coupler S KNX Line coupler S KNX 9070880 Status: March 16 (Subject to change) Page 1 of 29 KNX Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Structure

More information

ATTACHMENT LINE COUPLER KNX-301-DIN

ATTACHMENT LINE COUPLER KNX-301-DIN ATTACHMENT LINE COUPLER KNX-301-DIN VER. 1.2. CONTENTS 1. SUMMARY... 2 2. APPLICATION DESCRIPTION COUPLER... 2 2.1. COUPLER... 2 2.2. REPEATER... 2 3. PARAMETER SETTING DESCRIPTION IN THE ETS...2 3.1.

More information

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Line Coupler, MDRC LK/S 3.1, GH Q R0001 , GH Q605 0067 000 The coupler can be used as a line The coupler is installed in the distribution board on the data rail of the coupler or a backbone coupler. CDC 07 0 F000 As a line coupler, it links

More information

CU-DIN USB KNX EC

CU-DIN USB KNX EC CU-DIN USB KNX EC10430541 MA00653301 Table of contents 1 Description...2 2 Safety instructions...3 3 Dimension drawings...4 4 Technical data...5 5 Product disposal...6 6 ESYLUX manufacturer s guarantee...6

More information

Product and Applications Description

Product and Applications Description IP N146/02 Product and Applications Description The IP N146/02 is a DIN rail mounted device. The device implements the KNXnet/IP standard and connects KNX/EIB lines via data networks using the Internet

More information

Line Coupler, MDRC LK/S 2.1, GH Q R0001

Line Coupler, MDRC LK/S 2.1, GH Q R0001 , GH Q605 0019 R0001 The coupler can be used as a line In the distribution board the coupler is coupler or as an area coupler. Used as installed on the secondary line of the a line coupler it joins up

More information

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011 Technical Data 2CDC502086D0201 Product description IP Router 3.1.1 is the interface between KNX installations and IP networks. It can be used as a line coupler or area coupler and can utilize the local

More information

instabus KNX / EIB product documentation

instabus KNX / EIB product documentation Page: 1 of 21 System Product name: (R2) Design: REG (rail-mounted ) Article-no.: J: IPR 100 REG ETS search System s / / path: Issue: 05.03.2010 Functional description: This describes the with the release

More information

DELTA i-system wall switch single UP 221/2 5WG AB_2

DELTA i-system wall switch single UP 221/2 5WG AB_2 DELTA i-system wall switch single UP 221/2 5WG1 221-2AB_2 UP 221/3,with status LED 5WG1 221-2AB_3 wall switch double UP 222/2, 5WG1 222-2AB_2 UP 222/3,with status LED 5WG1 222-2AB_3 wall switch triple

More information

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions EN Operation and installation manual IP (Art. # 5212) Power supply with integrated IP Router and diagnosis functions Switch LAN IP 1.1.0 IP 2.1.0 1.1.1 1.1.7 2.1.1 2.1.7 1.1.2 1.1.8 2.1.2 2.1.8 1.1.3 1.1.9

More information

Push Button Interface UP 220D31

Push Button Interface UP 220D31 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall

More information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation

More information

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011 Technical Data 2CDC505168D0201 ABB i-bus KNX Product description The Analogue Actuator converts telegrams received via KNX into analog output signals. The device has four outputs. The analog outputs can

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Product and Application Description

Product and Application Description Technical Product-Information Product and Application Description The IP Gateway KNX-BACnet N 143 is is a DIN rail mounted device connecting a KNX installation with a system using BACnet/IP communication.

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies PRODUCT MANUAL ABB i-bus KNX SV/S KNX-Power Supplies Contents Contents side 1 General... 3 1.1 Using the product manual...3 1.1.1 Structure of the product manual...4 1.1.2 Notes...4 1.2 Product and functional

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

IP gateway, MDRC IG/S 1.1, GH Q R0001

IP gateway, MDRC IG/S 1.1, GH Q R0001 , GH Q631 0067 R0001 The IP gateway IG/S is the interface The IP address of the IG/S can be between EIB / KNX installations and IP fixed or received from a DHCP server. CDC 071 130 F0003 networks. Data

More information

DELTA profil wall switch, single UP 241/2 5WG AB_2

DELTA profil wall switch, single UP 241/2 5WG AB_2 UP 241/2 5WG1 241-2AB_2 UP 241/3,with status LED 5WG1 241-2AB_3 UP 243/2 5WG1 243-2AB_2 UP 243/3,with status LED 5WG1 243-2AB_3 UP 245/2 5WG1 245-2AB_2 UP 245/3,with status LED 5WG1 245-2AB_3 UP 245/4,with

More information

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX AC/S Application Controller ABB i-bus KNX AC/S 1.2.1 Application Controller Description of product Automation controller with pre-defined automation modules for comprehensive heating, ventilation and air conditioning automation (HVAC

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

AB Axis Industries. Use

AB Axis Industries. Use AB Axis Industries PULSE ADAPTER ENCO PULSE The ENCO PULSE pulse adapter acquires and handles the pulses from consumption meters with pulse output and transmits the data to a network of AMR system. Use

More information

Operation and installation manual KNX IP Router. Application. Coupler function (KNXnet/IP Routing)

Operation and installation manual KNX IP Router. Application. Coupler function (KNXnet/IP Routing) EN Operation and installation manual Ref. 9018248B Compact bus powered Router between LAN/Ethernet and KNX bus Application The allows forwarding of telegrams between different lines (TP) through a LAN

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011 Technical Data 2CDC504084D0201 ABB i-bus KNX Product description The device is used to record analogue data. Four conventional sensors can be connected to the device. The connection to the bus is established

More information

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm 2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be

More information

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00 CAN-Bridge CAN Communications Module for CAN 2.0 A/B, CAN Layer 2 700-660-2AA01 Manual Version 1/26.01.2011 from HW 1 & FW 1.00 Manual order number 700-660-2AA01/en Systeme Helmholz GmbH Hannberger Weg

More information

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions

More information

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A Characteristics regulated SMPS - 1 or 2 phase - 120..230 V AC - 24 V - 5A Complementary Input voltage limits Network frequency Inrush current Main Range of product Product or component type Power supply

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

Weather station AP 257/51

Weather station AP 257/51 Gamma instabus Weather station GPS AP 257/61 Weather station AP 257/51 Technical product information 5WG1 257-3AB61 5WG1 257-3AB51 Weather station with sensors to survey temperature, brightness, rain and

More information

Power Supply System KNX PS640-IP

Power Supply System KNX PS640-IP Power Supply System KNX PS640-IP with Ethernet Interface Installation and Adjustment Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Product and Function Description

Product and Function Description Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch

More information

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011 Technical data 2CDC509078D0201 ABB i-bus KNX Product description The device provides extensive logic functions. The logic is defined via a graphic editor integrated in the ETS. Up to 3,000 logic gates

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Application description for the KNXnet/IP Interface Web

Application description for the KNXnet/IP Interface Web Contents 1. General 1. General... 1 1.1 Basic information about the KNX/EIB BUS... 1 1.2 Application versions......1 1.3 Symbols...1 1.4 Function description... 2 1.5 Short description of the function

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161 Technical Data 9AKK107045A4913 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

Weather station GPS AP 257/61 Weather station AP 257/51

Weather station GPS AP 257/61 Weather station AP 257/51 Gamma instabus Weather station GPS AP 257/61 Weather station AP 257/51 Technical product information 5WG1 257-3AB61 5WG1 257-3AB51 Weather station with sensors to survey temperature, brightness, rain and

More information

Push button UP 287, 4 - fold

Push button UP 287, 4 - fold Product DELTA profil DELTA style Push button 1-fold pearl grey 5WG1 241-2AB01 titanium white 5WG1 285-2AB11 titanium white 5WG1 241-2AB11 basalt black 5WG1 285-2AB21 anthracite 5WG1 241-2AB21 titanium

More information

CU port USB 2.0 hub. Version: 1.1 Date:

CU port USB 2.0 hub. Version: 1.1 Date: CU8004-0000 4 port USB 2.0 hub Version: 1.1 Date: 2006-08-11 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions of delivery

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

EAE KNX Switch Actuator

EAE KNX Switch Actuator EAE KNX Switch Actuator Order Number: 48002 Content 1 General... 2 2 Device Technology... 3 2.1 Connection Diagram... 3 2.2 Technical Data... 4 3 Communication Object Table... 5 4 Parameters... 6 4.1 Main

More information

Gas Controller System DGC-06

Gas Controller System DGC-06 Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN

More information

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011 Technical Data 2CDC505054D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.6.2.1, 10 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

TXM1.8RB. TX-I/O Blinds module

TXM1.8RB. TX-I/O Blinds module s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1

More information

crio PN Installation Instructions V0.2/ COMSOFT

crio PN Installation Instructions V0.2/ COMSOFT crio PN Installation Instructions V0.2/10.06.2015 COMSOFT crio PN-Installation- V0.2/10.06.2015 i:\icp\project\700391_crio_pn\anwenderdoku\installation\version_0.2\crio_pn_e.doc Revision History Version

More information

The network node works extremely well in more complex building environments (e.g. where fire doors/glass walls are installed).

The network node works extremely well in more complex building environments (e.g. where fire doors/glass walls are installed). Data sheet / 12.10.2015 - V 1.0 Network node Q node 5 The network node Q node 5 receives and processes data from consumption metering devices within the Q AMR system. The network node works extremely well

More information

Resistance measuring module

Resistance measuring module s 8 176 8176P01 TX-I/O Resistance measuring module TXM1.8P 8 inputs with LED signal / fault display. 8 resistance measuring inputs with individual configuration of resistance or temperature measurement.

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

IntesisBox KNX SAMSUNG NASA Air Conditioners

IntesisBox KNX SAMSUNG NASA Air Conditioners IntesisBox KNX SAMSUNG NASA Air Conditioners Gateway for integration of Samsung NASA air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX/EIB bus R1/R2 EIA485 SM-ACN-KNX-4-8-16-64

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011 , 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for

More information

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 60 W Main Range of product Product or component type Power supply type Rated power in W Input voltage Output voltage Power

More information

USER MANUAL. Longo programmable controller LPC-2.EO1 EnOcean Wireless module. Version 1

USER MANUAL. Longo programmable controller LPC-2.EO1 EnOcean Wireless module. Version 1 USER MANUAL Longo programmable controller LPC-2.EO1 EnOcean Wireless module Version 1 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

More information

ERF910. RF Repeater. Synco living

ERF910. RF Repeater. Synco living 2 704 Synco living RF Repeater ERF910 Wireless RF repeater for extending plant RF communication based on KNX standard (868 MHz, bidirectional) Mains-powered AC 2 V (with external power pack) Use For integration

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 38W 5-7mA flexc lp ACED series Product description Built-in constant current ED Driver Adjustable output current between 5 and 7 ma Max. output power 38 W Up to 85 % efficiency ominal life-time

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

Handheld Tool for VAV compact and modular controllers

Handheld Tool for VAV compact and modular controllers s OpenAir VAV Handheld Tool AST20 Handheld Tool for VAV compact and modular controllers For configuration and maintenance of OpenAir VAV compact and modular controllers: For use in OEM factory for configuration

More information

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618 1 SIMATIC Sensors RF systems Wide-range power supply unit for SIMATIC RF systems Operating Instructions 11/2007 J31069-D0169-U001-A4-7618 Safety Guidelines This manual contains notices you have to observe

More information

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011 Technical Data 2CDC505082D0203 ABB i-bus KNX Product description Switch Actuators SA/S x.16.6.1, 16/20 A are modular installation devices in ProM design for installation in the distribution board. They

More information

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 5 A Main Range of product Product or component type Power supply type Input voltage Output voltage Rated power in W Input protection

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 57W 8-5mA flexc lp ACED series Product description Built-in constant current ED Driver ew version DC operating with E marking Adjustable output current between 8 and,5 ma Max. output power 57

More information

Network node WTT56.. A6V _en--_c Building Technologies

Network node WTT56.. A6V _en--_c Building Technologies s Network node WTT56.. The WTT56.. network node is used to receive and handle the data transmitted by heat cost allocators, heat and water meters incorporated in a radio network. Storage of up to 500 metering

More information

584 5WG AB_1 DELTA

584 5WG AB_1 DELTA Product DELTA profil DELTA style DELTA ambiente Display and control unit 5WG1 585-2AB01 pearl grey 5WG1 585-2AB11 titanium white 5WG1 585-2AB21 anthracite 5WG1 585-2AB71 silver 5WG1 585-2AB11 titanium

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver C 9W 5-35mA flexc lp ACED series Product description Built-in constant current ED Driver Adjustable output current between 5 and 35 ma Max. output power 9 W Up to 84 % efficiency ominal life-time

More information

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.: Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial

More information

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point

More information

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1

More information

SK CU4-PNT-C Part number:

SK CU4-PNT-C Part number: SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Installation Guide DEVIlink CC Central Controller

Installation Guide DEVIlink CC Central Controller DEVIlink CC Central Controller www.devi.com Table of Contents 1 Introduction.................................... 4 2 Guidelines for installation....................... 5 3 Installation plan.................................

More information

C-DIAS EtherNet/IP Slave CIP 022

C-DIAS EtherNet/IP Slave CIP 022 C-DIAS-ETHERNET/IP SLAVEMODUL CIP 022 C-DIAS EtherNet/IP Slave CIP 022 The C-DIAS EtherNet/IP CIP 022 slave module is an interface module between the C-DIAS control system and EtherNet/IP bus. Technical

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters KC-351 Series Installation Guide -1- DOC.070820-KC-351 (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information