1 Technical white paper vsphere 5.5 with HP OneView, 3PAR StoreServ 7400, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma and Marcus D'Andrea, HP DIA

2 Table of contents Introduction... 4 Testing Physical Topology... 5 Networking and Storage Switching Connectivity... 7 Cisco Nexus 5672UP Provisioning... 7 Brocade 6510 Provisioning NPIV Configuration Zone Alias Configuration Zoning configuration Server Infrastructure OneView Sample Initial Configuration (Using OneView Simulator) Initial Login Create Ethernet Networks Create Network Set Create Logical Interconnect Group Create Uplink Set Create Enclosure Group Add Enclosure Verify Logical Interconnect and Upgrade Virtual Connect Firmware Verify Interconnect Create Server Profile Firmware Repository: Licensing REST API and PowerShell Library Virtual Connect FlexFabric-20/40 F8 Module Ports and Port Numbering Server Port/MAC/WWPN Mapping OneView Final Config with Virtual Connect FlexFabric-20/40 F8 Module Networking Uplinks Configuration to Nexus SAN Uplinks Configuration to Brocade Server Downlink Network Set Configuration Server Profile Configuration HP 3PAR StoreServ 7400 Infrastructure Deployment PAR StoreServ 7400 Hardware Overview Node Enclosure Drive Enclosure Enclosure Cabling HP 3PAR Service Processor Page 2

3 Storage System and Service Processor Initialization PAR StoreServ 7400 Software Configuration vsphere 5.5 Infrastructure Host Networking Configuration Host Storage Configuration HP 3PAR Storage SATP and PSP setting HP 3PAR VAAI Plugin for ESXi 5.x Storage Connectivity Verification HP OneView Integration with HP 3PAR and Brocade Network Advisor for Auto Volume Creation and Zoning HP OneView with 3PAR StoreServe Integration PAR Configuration OneView Configuration HP OneView with Brocade Network Advisor Integration Brocade Network Advisor Configuration OneView Configuration Provisioning host LUN with 3PAR Auto Export and Brocade Auto Zoning HP OneView and 3PAR StoreServ Integration with VMware vcenter Software Installation Storage Administrator Portal Configuration vsphere Web Client Configuration HP Infrastructure Management Host Networking Management Network Diagram Network Detail HP Storage Management Host Operation Management OneView for vcenter and Insight Control Server Provisioning Grow ESXi Cluster HP Insight Control Server Provisioning Insight Control Server Provisioning Custom Build Plan OneView for vcenter HP Grow Cluster OneView for vcenter End to End Datastore Provisioning Conclusion Page 3

4 Introduction This document describes the deployment procedures for building a comprehensive infrastructure that uses technologies from HP, VMware, Cisco, and Brocade. Beyond the fundamental Server/Storage/Networking configuration for VMware vsphere 5.5, in the later sections, we highlight some powerful features leveraging the integration among HP OneView management, HP 3PAR StoreServ Storage, Brocade Network Advisor and VMware vcenter. Such features include end-to-end vsphere cluster growing and datastore creation. The hardware and software for vsphere 5.5 deployment testing include the following: Infrastructure Components Products Version Blade server H/W HP BladeSystem C7000 Chassis with ProLiant BL460 Gen8 servers SPP Blade server I/O HP Virtual Connect FlexFabric-20/40 F8 Module for c-class BladeSystem 4.20 Storage HP 3PAR StoreServ node system 3.1.3(MU1) Networking Cisco Nexus 5672UP Switches NX-OS 7.0(1)N1(1) SAN Fabric Brocade 6510 Switches FOS: v7.0.2c Management S/W Products Version Infrastructure Management HP Server/Storage vcenter Integration HP OneView infrastructure management virtual appliance 1.10 HP OneView for VMware vcenter for OneView server and 3PAR storage vcenter integration HP OS Provisioning HP Insight Control Server Provisioning Although this is the default base design, each of the components can be scaled to support specific business requirements. For example, different quantities or combinations of blades and chassis can be deployed to increase compute capacity; additional disk shelves can be deployed to improve I/O capacity and throughput; and special hardware or software features can be added to introduce new features Page 4

5 Testing Physical Topology Nexus Nexus vpc Peer Link vpc101 vpc102 vpc101 vpc102 HP BladeSystem c7000 With Virtual Connect FlexFabric-20/40 F8 Module MGMT Brocade Brocade FC Ethernet HP 3PAR StoreServ Node HP BladeSystem C7000 chassis is loaded with HP ProLiant BL460c Gen8 blades. All blade servers I/Os are provided by the Virtual Connect FlexFabric 20/40-F8 interconnect module. HP 3PAR StoreServ 7400 provides server storage for VMware datastore. 3PAR StoreServ not only provides Tier-1 storage performance and features like Adaptive Optimization but it is also is integrated with HP OneView infrastructure management platform for ease of provisioning. Ethernet networking consists of a pair of Cisco Nexus 5672UP switches. Nexus 5600 series are upgraded models over Nexus 5500 switches. The same vpc configuration guidelines with HP Virtual Connect modules discussed in this paper also apply to other Cisco Nexus product lines including Cisco Nexus 9000, Nexus 7000, Nexus 6000 and Nexus We chose the Nexus 5600 platform because Cisco Nexus 5500s are widely deployed and connected with Virtual Connect in Data Center. We wanted to validate the latest Virtual Connect FlexFabric-20/40 F8 module interoperability with Nexus 5600/5500. Virtual Connect can also work with other data center switches from HP Network, Brocade, Arista, Juniper, Extreme, etc. Future OneView releases will support FCOE uplink from Virtual Connect to Nexus switches. 40G uplink testing of Virtual Connect FlexFabric-20/40 F8 module has been covered in another separate technical white paper. The SAN fabric consists of a pair of Brocade 6510 switches. The 6510 switch is the latest Brocade Gen 5 Fibre Channel product. It offers 48x16G FC ports. We tested 8G FC speed because Virtual Connect and 3PAR StoreServ support up to 8G FC interface. We Page 5

6 choose Brocade because of its leadership position in data center Fibre Channel fabric market. Meanwhile, HP OneView has built-in integration with Brocade Network Advisor to automatically provision SAN fabric for automatic zoning between servers and Fibre Channel storage array. HP OneView and Virtual Connect module can also work with Cisco MDS FC switches. Server infrastructure management is provided by HP OneView software. HP OneView is HP s converged infrastructure platform managing server provisioning, monitoring, and LAN/SAN networking configuration tasks. HP OneView integrates functions of all traditional HP management software such as Onboard Administrator, Virtual Connect Manager, Virtual Connect Enterprise Manager and Insight Control software. Beyond it, it also has built-in Brocade SAN Fabric as well as HP 3PAR StoreServ storage provisioning integration. We also tested OneView for vcenter plugin and Insight Control Server Provisioning to demonstrate ease of management for HP server provisioning and monitoring through VMware vcenter. Page 6

7 Networking and Storage Switching Connectivity Cisco Nexus 5672UP Provisioning Eth1/3 Nexus Nexus vpc Peer Link Eth1/3 Eth1/2 Eth1/2 vpc102 vpc102 vpc101 vpc101 Ethernet X5 X6 X5 X6 The two Nexus 5672 UP switches are set up as vpc cluster. When deploying Virtual Connect with Nexus switches vpc technology, typically one Virtual Connect module will have one link connecting to switch-1 and another link connecting to switch-2. On Switch side, users should configure one vpc port-channel on both switches for the vpc switches communicating with this Virtual Connect module. Users should follow the same above cabling and configuration guidelines for the second Virtual Connect module. In summary, each Nexus switch should have two vpc port-channels, the first one is for communication with the first virtual connect module and the second one is for communication with the second virtual connect module. In our testing, Eth1/2 on both Nexus 5672 switches are connected with the first VC FF-20/40 F8 module in I/O bay 3 and the two Eth1/2 are bundled under vpc port-channel 101. Eth1/3 on both Nexus 5672 switches are connected with the second VC FF-20/40 F8 module in I/O bay 4 and the two Eth1/3 are bundled under vpc port-channel 102. Note: The most common mistakes when configuring Virtual Connect with Nexus vpc are a) not following the above cabling guidelines and b) try to config one port-channel bundling four links together across Nexus and Virtual Connect. Virtual Connect does NOT support LACP across two modules so two vpc port-channels should be created. Users can verify cabling between Virtual Connect and Nexus by using show lldp neighbor command. The following CLI captures verified the first VC FF-20/40 F8 module (with S/N: 7C in I/O Bay 3) is connecting its X5 port to Nexus Eth1/2 and its X6 port to Nexus Eth1/2. The second VC FF-20/40 F8 module (with 7C941201CR in I/O Bay 4) is connecting its X5 port to Nexus 5601 Eth 1/3 and its X6 port to Nexus Eth1/3. Page 7

8 DIA # show lldp neighbors Device ID Local Intf Hold-time Capability Port ID... VC2040F8-7C SERIAL NO:7C BAY:3Eth1/2 120 X5 VC2040F8-7C941201CR SERIAL NO:7C941201CR BAY:4Eth1/3 120 X5... DIA # show lldp neigh Device ID Local Intf Hold-time Capability Port ID... VC2040F8-7C SERIAL NO:7C BAY:3Eth1/2 120 X6 VC2040F8-7C941201CR SERIAL NO:7C941201CR BAY:4Eth1/3 120 X6... When configuring Nexus port VLAN trunking with HP Virtual Connect modules, there are several things to note: Treat virtual connect ports as regular host trunk ports. Virtual Connect does NOT use STP to communicate with upstream switches. For control signaling, Virtual Connect only uses standard LLDP and LACP with upstream switches for neighbor discovery and port bundling. Typically users will configure trunk ports on Nexus switch when connecting with Virtual Connect in the context of hypervisor environment. Users should config STP edge port trunk for ports connecting with Virtual Connect. This is to prevent switches STP blocking Virtual Connect uplinks for up to 30 seconds upon its connectivity restoration in the event of module upgrade and link failure. Optionally, one VLAN could be selected as native VLAN for the trunk but OneView Uplink configuration should also mark this VLAN as native. Optionally, users can enable BPDU guard under the interfaces or enable them as global default setting to safeguard switching domain from any devices in the server edge. The following capture shows the vpc port-channel 101 configuration on both Nexus 5672 switches to connect with the first Virtual Connect Module. DIA # show run int po101 membership interface port-channel101 switchport mode trunk switchport trunk allowed vlan spanning-tree port type edge trunk spanning-tree bpduguard enable speed vpc 101 interface Ethernet1/2 switchport mode trunk switchport trunk allowed vlan channel-group 101 mode active DIA # show run int po101 membership interface port-channel101 switchport mode trunk switchport trunk allowed vlan spanning-tree port type edge trunk spanning-tree bpduguard enable speed vpc 101 interface Ethernet1/2 switchport mode trunk switchport trunk allowed vlan channel-group 101 mode active Page 8

9 The following capture shows the vpc port-channel 102 configuration on both Nexus 5672 switches to connect with the second Virtual Connect Module. DIA # show run int po102 membership interface port-channel102 switchport mode trunk switchport trunk allowed vlan spanning-tree port type edge trunk spanning-tree bpduguard enable speed vpc 102 interface Ethernet1/3 switchport mode trunk switchport trunk allowed vlan channel-group 102 mode active DIA # show run int po102 membership interface port-channel102 switchport mode trunk switchport trunk allowed vlan spanning-tree port type edge trunk spanning-tree bpduguard enable speed vpc 102 interface Ethernet1/3 switchport mode trunk switchport trunk allowed vlan channel-group 102 mode active The following capture shows the vpc status on both nexus 5672 switches. DIA # show vpc... vpc Peer-link status id Port Status Active vlans Po1 up 1,40, vpc status id Port Status Consistency Reason Active vlans Po101 up success success Po102 up success success DIA # show vpc... vpc Peer-link status id Port Status Active vlans Po1 up 1,40, vpc status id Port Status Consistency Reason Active vlans Po101 up success success Page 9

10 102 Po102 up success success The following capture verifies the switches received 0 BPDU packets from Virtual Connect. DIA # show spanning-tree interface port-channel 101 detail Port 4196 (port-channel101, vpc) of VLAN0160 is designated forwarding Port path cost 1, Port priority 128, Port Identifier Designated root has priority 24736, address 002a.6a13.c3c1 Designated bridge has priority 61600, address 002a.6ae0.a601 Designated port id is , designated path cost 2 Timers: message age 0, forward delay 0, hold 0 Number of transitions to forwarding state: 2 The port type is edge by port type edge trunk configuration Link type is point-to-point by default Bpdu guard is enabled BPDU: sent 66545, received 0... Although this section focuses on Cisco Nexus configuration, it s import for the network team to work with server team to verify connectivity so we d like to show some OneView captures so that users can quickly relate information between Nexus and Virtual Connect uplink ports. We ll cover detailed OneView setup in the later section. Users can verify Virtual Connect physical connectivity to Nexus switches in OneView Interconnect section. The following captures verified module serial number. Page 10

11 The following capture verified Virtual Connect uplink port LLDP neighbor information. Page 11

12 The following capture shows the first VC FF-20/40 F8 module LACP uplink configuration corresponding to vpc port-channel 101 on both switches. Page 12

13 The following capture shows the second VC FF-20/40 F8 module LACP uplink configuration corresponding to vpc port-channel 102 on both switches. Page 13

14 Page 14

15 Brocade 6510 Provisioning X1 X2 X1 X2 0 1 Brocade Brocade HP 3PAR StoreServ Node 1:2:4 1:2:3 FC SAN Fabric consists of a couple of Brocade 6510 switches running Fabric OS. On HP VC FF-20/40 F8 modules, X1 and X2 for each module are configured as native FC ports with 8G FC transceivers plugged in. The first VC module is connected with switch for SAN Fabric-A access. The second VC module is connected with switch for SAN Fabric-B access. 3PAR 7400 port 0:2:3(Node1:Slot2:Port3) and 1:2:3(Node2:Slot2:Port3) are connected with for SAN Fabric-A access while port 0:2:4 and 1:2:4 are connected with for SAN Fabric-B access. The above 3PAR mirrored cabling between 7400 paired nodes can support 3PAR Persistent Ports feature, which can provide transparent traffic switch over to server workload upon the node failure/upgrade. SAN Fabric switches need to provision the following tasks: Turn on NPIV for ports connecting with Virtual Connect and 3PAR 7400 Optionally set up zone alias 0:2:3 0:2:4 Zoning manually or automatically (through Brocade Network Advisor integration with OneView) Page 15

16 NPIV Configuration On the Brocade 300, 5100, 5300, 6510, and 8000 switches, the Brocade 5410, 5424, 5450, 5460, 5470, and 5480 embedded switches, Brocade DCX, DCX-4S, and DCX 8510 enterprise-class platforms, and the FA4-18 blade, NPIV is enabled for every port. DIA-BSAN-01:FID3:admin> portcfgshow Ports of Slot Octet Speed Combo Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AL_PA Offset Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port ON Disabled E_Port Locked E_Port ISL R_RDY Mode RSCN Suppressed Persistent Disable LOS TOV enable NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON <output truncated> To verify blade servers logged into Brocade 6510 through HP Virtual Connect using NPIV, we can user switchshow command to verify switch port has NPIV login, in this case one blade server logged into port 1 on (through the first VC FF-20/40 F8 uplink port X6). DIA-BSAN-01:FID3:admin> switchshow switchname: DIA-BSAN-01 switchtype: switchstate: Online switchmode: Native switchrole: Principal switchdomain: 1 switchid: fffc01 switchwwn: 10:00:00:27:f8:c3:ce:02 zoning: ON (SAN_A) switchbeacon: OFF FC Router: OFF Allow XISL Use: OFF LS Attributes: [FID: 3, Base Switch: No, Default Switch: Yes, Address Mode 0] Index Port Address Media Speed State Proto ============================================== id N8 Online FC F-Port 20:00:00:11:0a:04:06:e id N8 Online FC F-Port 1 N Port + 1 NPIV public <output truncated> portshow can verify login device WWPN information. 10:00:ce:16:0f:90:00:00 is blade server HBA port 0 address. 20:01:00:11:0a:04:06:e6 is the first VC-20/40 F8 module X6 port address. DIA-BSAN-01:FID3:admin> portshow 1 <Output truncated> portwwn: 20:01:00:27:f8:c3:ce:02 portwwn of device(s) connected: 10:00:ce:16:0f:90:00:00 20:01:00:11:0a:04:06:e6 <output truncated> portloginshow verifies Port Identifier PID is assigned to the blade HBA for routing and zoning purpose. DIA-BSAN-01:FID3:admin> portloginshow 1 Type PID World Wide Name credit df_sz cos ===================================================== fe :00:ce:16:0f:90:00: c scr=0x3 fe :01:00:11:0a:04:06:e c scr=0x0 Page 16

17 ff :00:ce:16:0f:90:00: d_id=fffffc DIA-BSAN-01:FID3:admin> From Brocade Web Tool, we can also verify the same port login information. The following captures are from Brocade You can see the same blade server logged into port 0 on (through the second VC FF-20/40 F8 uplink port X5). DIA-BSAN-02:FID128:admin> switchshow switchname: DIA-BSAN-02 switchtype: switchstate: Online switchmode: Native switchrole: Principal switchdomain: 1 switchid: fffc01 switchwwn: 10:00:00:27:f8:c3:40:e2 zoning: ON (SAN_B) switchbeacon: OFF FC Router: OFF Allow XISL Use: OFF LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Address Mode 0] Index Port Address Media Speed State Proto ============================================== id N8 Online FC F-Port 1 N Port + 2 NPIV public id N8 Online FC F-Port 1 N Port + 1 NPIV public <output truncated> 10:00:ce:16:0f:90:00:02 is blade server HBA port 1 address. 20:00:00:11:0a:04:03:81 is the second VC-20/40 F8 module X5 port address. DIA-BSAN-02:FID128:admin> portshow 0 <output truncated> portwwn: 20:00:00:27:f8:c3:40:e2 portwwn of device(s) connected: 10:00:ce:16:0f:90:00:1e 10:00:ce:16:0f:90:00:02 20:00:00:11:0a:04:03:81 <output truncated> Page 17

18 DIA-BSAN-02:FID128:admin> portloginshow 0 Type PID World Wide Name credit df_sz cos ===================================================== fe :00:ce:16:0f:90:00:1e c scr=0x3 fe :00:ce:16:0f:90:00: c scr=0x3 fe :00:00:11:0a:04:03: c scr=0x0 ff :00:ce:16:0f:90:00:1e d_id=fffffc ff :00:ce:16:0f:90:00: d_id=fffffc From Brocade Web Tool, we can also verify port login information. Although this section is focusing on the Brocade configuration, we are attaching some screen captures from OneView server side and 3PAR storage side so you can easily map out ports/pwwns across fabric. Detailed OneView and 3PAR configurations will be discussed in the following sections. The following capture shows two VC FF-20/40 F8 modules uplink connectivity. The very right column is VC module uplink port PWWN and the column to the left is logged-in Brocade switch NWWN (verified by switchshow command on Brocade). Page 18

19 The following capture shows the blade server HBA 0 and 1 PWWN/NWWN. 3PAR port PWWN addresses can be verified through 3PAR CLI or GUI Management Console. DIA-3PAR-01 cli% showport grep 0:2:3 1:2:3 0:2:4 1:2:4 N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState 0:2:3 target ready 2FF70002AC00ADEC AC00ADEC host FC - 1:2:3 none 0:2:4 target ready 2FF70002AC00ADEC AC00ADEC host FC - 1:2:4 none Page 19

20 1:2:3 target ready 2FF70002AC00ADEC AC00ADEC host FC - 0:2:3 none 1:2:4 target ready 2FF70002AC00ADEC AC00ADEC host FC - 0:2:4 none Zone Alias Configuration After verifying all connectivity, we can optionally create alias using Brocade Web Tool or CLI for zoning in the next step. The following capture verifies alias configuration for both switches. DIA-BSAN-01:FID3:admin> alishow <output truncated> alias: HP_3PAR_Port_023 20:23:00:02:ac:00:ad:ec alias: HP_3PAR_Port_123 21:23:00:02:ac:00:ad:ec alias: HP_C7K_03_Blade4_Mezz1_A 10:00:ce:16:0f:90:00:00 <output truncated> DIA-BSAN-02:FID128:admin> alishow <output truncated> alias: HP_3PAR_Port_024 20:24:00:02:ac:00:ad:ec alias: HP_3PAR_Port_124 21:24:00:02:ac:00:ad:ec alias: HP_C7K_03_Blade4_Mezz1_B 10:00:ce:16:0f:90:00:02 <output truncated> Zoning configuration 3PAR best practice prefers one to one zoning between server initiator and 3PAR target so inside each fabric, we ll create two zones. The first one is from server HBA to the first 3PAR port and the second is from the same server HBA to the second 3PAR port in this fabric. The following shows the effective zone configuration from CLI and GUI. DIA-BSAN-01:FID3:admin> zoneshow <output truncated> Effective configuration: zone: Blade4_3PAR_Node0 20:23:00:02:ac:00:ad:ec 10:00:ce:16:0f:90:00:00 zone: Blade4_3PAR_Node1 21:23:00:02:ac:00:ad:ec 10:00:ce:16:0f:90:00:00 <output truncated> DIA-BSAN-02:FID128:admin> zoneshow <output truncated> Effective configuration: zone: Blade4_3PAR_Node0_FabricB 20:24:00:02:ac:00:ad:ec 10:00:ce:16:0f:90:00:02 zone: Blade4_3PAR_Node1_FabricB 21:24:00:02:ac:00:ad:ec 10:00:ce:16:0f:90:00:02 Page 20

21 Page 21

22 Server Infrastructure HP BladeSystem c7000 enclosure hosts VMware hosts. Server infrastructure management is provided by HP OneView software. HP OneView is HP converged infrastructure platform managing server provisioning, monitoring, and LAN/SAN networking configuration tasks. HP OneView integrates functions of all traditional HP management software such as Onboard Administrator, Virtual Connect Manager, Virtual Connect Enterprise Manager and Insight Control software. First released in September, 2013, OneView version tested in the setup was OneView software is packaged as VMware virtual appliance ova format. Users can download software at Detailed HP OneView installation and initial setup procedure are discussed in HP OneView 1.10 Deployment and Management Guide. OneView Sample Initial Configuration (Using OneView Simulator) The following sections will help users to walk-through a typical OneView setup scenario starting from importing a HP BladeSystem C7000 chassis to complete provisioning of a server profile. Note: The following screens were captured using OneView simulator with Virtual Connect FlexFabric 10Gb/24-port modules where VLAN 125 was MGMT vlan, 160 was vmotion and 161 was NFS. In this white paper, VLAN 160 is MGMT where VLAN 162 is vmotion. Corresponding OneView final configuration for this paper matching Nexus and Brocade will be shown in the following section. Initial Login Upon finishing the OneView initial installation, users should be able to browse its address and login. The address was set up during virtual machine installation process. After login using the username/password set up during the installation process, users will be presented with default dashboard view. The dashboard will show zero for all entries upon initial login. Page 22

23 The next step naturally is importing BladeSystem c7000 enclosures so users can access server hardware and then define server profile for server LAN/SAN/BIOS settings. In order to import a c7000 enclosure, users have to create an Enclosure Group first. OneView uses the concept of Enclosure Group to logically group all c7000 enclosures with the same I/O modules configuration. Inside Enclosure Group, Logical Interconnect Group specifically defines these I/O module layout and configuration from a template perspective. Template settings for a Logical Interconnect Group include VLANs and SAN fabric inside Virtual Connect modules, Virtual Connect uplink port trunk allowed vlan configuration and physical ports assignment for the trunks. From the configuration steps perspective, users need to create VLAN, SAN fabrics inside Virtual Connect module to be ready for Logical Interconnect Group configuration. After successful creation of Logical Interconnect Group, Enclosure Group can then be defined and ready for importing a c7000 enclosure. Attempting to create Logical Interconnect Group without VLAN and SAN fabric defined will fail with the error that no Ethernet networks (vlans) are included in Logical Interconnect Group. Create Ethernet Networks Select Networks menu from top down list Select Create Network Page 23

24 Type in network name. The suffix -1 was chosen because this network will be assigned to Virtual Connect Module in I/O bay 1. The suffix string can be anything easier to identify vlans on different Virtual Connect Module. Select Type as Ethernet to have the network defined as an internal Ethernet vlan. Fibre Channel option will be used later when defining Virtual Connect internal SAN fabric. Select Tagged as vlan type so it can be used as one of vlans in Uplink Set contained in Logical Interconnect Group or Logical Interconnect. Even though it s marked as Tagged here, users will have the option to set the vlan as native in Logical Interconnect Group or Logical interconnect. In server downlinks, users can assign the single network to any server connection and the network will be untagged. Multiple networks can be assigned to a single server connection using Network Set and within Network Set, one of networks can be selected as Untagged. Other VLAN types like Untagged or Tunnel Type in 125 as vlan ID for management vlan. Leave Purpose as default General. This field is for some information correlation with HP OneView for vcenter. It has no operation impact or significance for OneView operation. Leave Preferred bandwidth as default 2.5Gbs. This parameter will preset the minimum guaranteed bandwidth value when this network is assigned to server NIC through server profile later. This value will only take effect when server is having congestion when sending traffic to Virtual Connect module. Leave Maximum bandwidth as default 10Gbs. If you have Virtual Connect Flexfabric-20/40 F8 and 20G adapters on servers, you can set this value to 20Gb. This parameter will preset the maximum allowed bandwidth value when this network is assigned to server NIC through server profile later. Leave Smart Link as checked by default so Virtual Connect can deactivate server downlinks when its uplinks failed. This will ensure server NIC teaming/bonding drive correctly failover to alternative path. Leave Private Network as unchecked by default. This option will block blade servers to communicate with each other on the same network when enabled. Page 24

25 Click Create button to finish creation of the network and back to overview view or Create+ button if users want to create other networks. Create all other required Ethernet networks as above After successful creation of Ethernet networks, users can continue to create FC networks as below if Fibre Channel will be used. Type in a network name corresponding to SAN Fabric A. Select Fibre Channel as network type. Leave Fabric Type as Fabric Attach by default. The other option Direct Attach is for Virtual Connect uplink FC ports directly connect with HP 3PAR storage array. Leave Associate with SAN as blank by default. This field is used when OneView is configured with Brocade BNA integration for SAN fabric provision automation. The discussion is out of scope of this white paper. Leave all other fields as default and click Create or Create+ button. Page 25

26 After successful creation of all Ethernet and FC networks, users can review all network information in overview page. Please note all Ethernet networks with -2 were vlan networks assigned to Virtual Connect in I/O Bay 2. Another FC network VSAN0002 was also created to map with SAN Fabric B. Page 26

27 Create Network Set The next optional step is to create Network Sets. Network Sets concept is strictly for Virtual Connect server downlinks. The use case will be to patch multiple Ethernet networks over a single server profile connection. Inside Network Sets, one network can be optionally set to untagged to match any server vlans requiring untagged packets like PXE network. Select Network Sets from top down menu. Select Create network set. Type in a network set name and click Add networks In VLAN selection window, users can filter vlan by type in -1 string, this will show only Ethernet networks with -1 in the name, Use CTRL or SHIFT to select all networks assigned to Virtual Connect module 1. These networks will be patched together using this Network Set towards server connections mapping to Virtual Connect module 1 later during server profile creation. Page 27

28 Leave Preferred bandwidth as default 2.5Gbs. This parameter will preset the minimum guaranteed bandwidth value when this network set is assigned to server NIC through server profile later. This value will only take effect when server is having congestion when sending traffic to Virtual Connect module. Leave Maximum bandwidth as default 10Gbs. If you have Virtual Connect Flexfabric-20/40 F8 and 20G adapters on servers, you can set this value to 20Gb. This parameter will preset the maximum allowed bandwidth value when this network set is assigned to server NIC through server profile later. Click Add to confirm adding networks to the network set and back to overview view. Optionally, users can set one network as Untagged. VLAN125-MGMT-1 was set as Untagged for VMware management network and PXE booting. Page 28

29 Create another network set as below to include all networks assigned to Virtual Connect module 2. Page 29

30 Review both network sets created. Create Logical Interconnect Group With all Ethernet networks/network sets and FC networks created, users are ready to create Logical Interconnect Groups. We ll define two uplink trunk template, one for VC module in I/O bay 1 and the other will be for VC module in I/O Bay 2. Select Logical Interconnect Groups from top down list. Select Create Logical Interconnect Group Type in LIG name and select Add Interconnect for I/O bay 1. Page 30

31 Create Uplink Set Choose HP VC FlexFabric 10Gb/24-port Module for both I/O Bay 1 and 2 and click Add uplink set. The VC module type and layout has to match users real installation scenario. In the Create uplink set window, Type in uplink-set name for VC I/O bay 1. Select Type as Ethernet for vlan trunk uplink to upstream switches. Leave Connection Mode as Automatic as default. Leave LACP timer as short as default, users can also choose Long option. Either mode should work with TOR switch in general. Click Add networks button. Page 31

32 Use searching with filter string of -1 to filter all vlans assigned to VC module 1, use CTRL or SHIFT to multi-select the networks and click Add button Page 32

33 Review all networks added and optionally configure one network as Native. If a native vlan is needed, the native vlan has to match with upstream switch native vlan setting. Click Add uplink ports button. Use CTRL or SHIFT to multi-select all physical ports on VC module 1 assigned to this uplink set, VC module 1 port X5 and X6 were selected in this case. Page 33

34 Review all networks inside the uplink set and all ports allocated and click Create button. Follow the same procedure to create another uplink set for VC module 2 and select all networks with -2 suffix and allocated VC module 2 port X5 and X6. Page 34

35 After Ethernet uplink sets are created, users can optionally define FC uplink set if FC is used for storage. In this case, two FC uplink sets were created. The first one was for VC module 1 to connect to Fabric A SAN switches and the other was for VC module 2 to connect to Fabric B SAN switches. Click Add uplink set in Logical Interconnect Group window. Type in FC uplink set name, Select Fibre Channel as uplink set type. Select VSAN0001 created previously for Fabric A as network. Select VC module 1 X1 as FC uplink port. Page 35

36 Follow the same procedure to create the second FC uplink set for SAN Fabric B and select VSAN0002 as FC network, choose VC module 2 X1 as physical port. Page 36

37 Review Logical Interconnect Group configuration and click Create. Page 37

38 Review LIG just created. Create Enclosure Group With the Logical Interconnect Group created, users can go ahead to create Enclosure Group to include this logical interconnect group. Select Enclosure Groups from top down list. Select Create enclosure group Page 38

39 Type in enclosure group name and select the logical interconnect group we just created and click Create button. Review enclosure group just created. Now OneView is ready to import enclosures with enclosure group just created. Select Enclosures from top down list Page 39

40 Add Enclosure Select Add enclosure. In Add Enclosure windows, Type in BladeSystem c7000 OA IP address or hostname, the OA IP should be set during enclosure initial installation. Provide OA username/password in Credentials fields. Select enclosure group just created. Optionally select Firmware baseline in OneView firmware repository (detailed in later section). Specify firmware SPP bundle here will upgrade OA, ilo firmware if they are older version than what s included in SPP baseline. The option Manage Manually will not upgrade OA, ilo versions if they meet OneView minimum required versions. However, if enclosure and blade ilo versions are below OneView requirement, OneView will still upgrade OA and ilo even when set to Manage Manually. As of version 1.10, OneView will NOT upgrade Virtual Connect firmware version during enclosure import process. Users have the option to upgrade VC firmware separately after enclosure import process. Server BIOS, CNA/HBA firmware could be upgraded when creating server profile and associate firmware baseline in the profile. Click Add button Page 40

41 After the enclosure is imported, users should verify enclosure information. Enclosure status should be Configured. Some warnings may be normal behavior, for the warnings below, users can click drop arrow sign to the right and see more details and it s concluded that no OneView license has been applied to the blades. Adding OneView license will be discussed in later section. Page 41

42 Verify Logical Interconnect and Upgrade Virtual Connect Firmware After importing enclosures using Enclosure Group and Logical Internet Group template, each c7000 enclosure will have a Logical Interconnect associated with it. The logical interconnect will have all LAN/SAN uplink configuration as we defined in logical interconnect group template. The difference between Logical Interconnect Group and Logical Group is that the former is a template concept while the latter is the real layer 2 configuration applied to a particular c7000 enclosure. Each c7000 enclosure will have one specific Logical Interconnect associated with it inside an enclosure group. Logical Interconnects for all c7000s will inherit the same configurations from the single Logical Interconnect Group template during enclosure import process. However, users can choose to change Logical Interconnect settings later for a specific c7000 enclosure. In that case, the Logical Interconnect configuration will different from original Logical Interconnect Template configuration. Users will get a warning message from OneView indicating the mismatch of the two and have the option to choose Update from Group from LI action menu or just leave this enclosure as a different configuration as the rest of enclosures in the same group. On the other side, in the case that users change the configuration of Logical Interconnect Group, all existing Logical Interconnects in the same enclosure group will be in the configuration mismatch status. OneView will warn the users for the status. Users should go to each enclosure Logical Interconnect and choose Update from group from LI action menu to acknowledge for configuration sync up from the template. As previous noted, during enclosure import process, VC firmware will not be updated. The next step after enclosure import is to go to Logical Interconnect for this enclosure to verify its firmware and status. Select Logical Interconnects from top down list. If the Virtual Connect firmware doesn t meet OneView minimum requirement, the Logical Interconnect will be in Unmanaged State. Users should select Action at top right corner and then select Update firmware to upgrade VC firmware. In this case, VC version met the minimum required version but was below the version contained inside firmware baseline so OneView will warn users to upgrade VC firmware to the newer version. Select Overview next to logical interconnect name. Page 42

43 Click "General" to display all Logical Interconnect information Scroll down to Firmware section to verify the current VC firmware version and the version contained in the firmware baseline. Page 43

44 Select Action and then Update Firmware Update window will display the default upgrade method. Accept default values and click OK. VC firmware update will be in progress. Page 44

45 After VC firmware upgrade, verify firmware status After the VC firmware is updated, verify Logical Interconnect configuration inherited and this specific enclosure uplink connectivity through logical interconnect. Select Logical Interconnects from top down list. Select "View next to logical interconnect name and select Uplink Sets section Page 45

46 Verify all network definitions inherited from Logical Interconnect Group and uplinks LACP status and Link connectivity. Verify all links status as Linked (Active) indicating successful LACP negotiation with upstream Cisco Nexus5500 switches running vpc. LAG ID is VC internal LACP bundle ID. Connected to indicates Nexus5500 port MAC address and interface number. Verify FC uplink connectivity status as Linked (logged in). Connected to field shows upstream FC local switch WWNN. Port WWN field is VC local port WWPN. Page 46

47 Verify Interconnect To check information on physical counters and transceivers, users can check Interconnects. The difference between Logical Interconnects and interconnects is the former focus mainly on layer 2 configuration such as VLAN, vlan tagging and LACP parameters where the latter focus on low level counters like packet statistics and transceiver status. Select Interconnects from top list menu. Select Interconnect 1 which refers to VC module in I/O bay 1, users can check FC uplink port counters and traffic information. Page 47

48 Users can also select Ethernet uplink and downlink ports and check physical transceivers and counters. Users can also check detailed LLDP neighbor information to show VC is connected with Nexus5500 eth1/1 interface. Page 48

49 After successfully configuring and verifying Virtual Connect module uplink status, users can check server hardware information and start to provision server profile. Create Server Profile Select Server Hardware from top down list. Review all server blade information, please note Server Profile column is none for all server bays, which means no server hardware is associated with any server profile Page 49

50 After verifying server hardware, users are ready to create server profiles. OneView implements server connectivity through attaching a server profile to any given server hardware. OneView can also create a server profile and assign to an empty server bay to pre-populate MAC and WWPN lists. Finally, OneView can create a profile and have the profile as unassigned status. Select Server profiles in top down list. Select Create Profile to create a new server profile. Please Note: If the server profile will be applied to a server blade, the server blade needs to be powered off in order for profile assignment. Users can go to Server Hardware section and select the server blade and click Power Off to power down the blade. Page 50

51 Type in a name for server profile Select which server bay the profile will be assigned to in Server Hardware field. Server hardware Type and Enclosure Group should be populated automatically after users specify server hardware. Leave Affinity field as device bay by default. This option controls if server profile can be applied if original server is unplugged and another server is plugged in. If the new server matches the server hardware type of the original server, the profile will be applied with device bay affinity. If the options is set to Device bay + Server Hardware, the profile will only be applied if the serial number of the blade matches the original blade. Optionally set Firmware Baseline to any SPP package you specified, the server profile will initiate the server to upgrade to firmware specified after profile creation. Click Add Connections to start specify vlan and SAN fabric for server physical NICs, CNAs and HBAs. In Add Connection window, specify Device Type as Ethernet and specify VLANs over this Ethernet NIC. In this case, we ll create two vmnics on VMware host. The first vmnic will be mapped to the first VC module and will carry all vlans created for VC module 1. The second vmnic will be mapped to the second VC module and will carry all vlans created for VC module 2. As previously noted, OneView uses the concept of Network Set to carry multiple vlans on a single NIC. From the network list below, users can select only ONE network or network set. If one network is specified, this network will carry the corresponding vlan traffic untagged to and from the server. In this case, VLAN-ALL-1 was selected to carry multiple vlans on the first NIC. This connection will be corresponding to vmnic0 on VMware host. Page 51

52 Optionally users can specify which FlexNIC this connection will be used. In most cases, default Auto will work as required. Leave Requested bandwidth as default 2.5Gbps. The value 2.5Gbps here is derived from previous Preferred bandwidth when creating network set VLAN-ALL-1. This is the minimum guaranteed bandwidth value for this network set when server is having congestion when sending traffic to Virtual Connect module. Users can optionally change the value here to overwrite previous defined preferred bandwidth specified in network or network set creation. Boot parameter specifies if this FlexNIC is allowed to do network PXE booting. In this case, it s changed from default Not bootable to Primary to allow PXE booting. Click Add+ to create this FlexNIC (vmnic0) and continue to create the 2 nd FlexNIC (vmnic1). Page 52

53 Follow the same steps to configure the second FlexNIC and select VLAN-ALL-2 as network set because this FlexNIC will be mapped to VC module 2. Click Add+ to create next FCOE/FC connection. Select Fibre Channel as device type and select VSAN0001 as FC network because the first FCOE connection will be mapped to VC Module 1 for SAN Fabric A. Page 53

54 Leave requested bandwidth and port as default. If users don t require BFS, the first FCOE or FC connection configuration is completed. In this case, this particular blade will do BFS so Boot field was changed from default Not Bootable to Primary. Users then need to type in storage array port WWPN connecting to SAN Fabric A and BFS LUN ID. Click Add+ to create second FCOE/FC connection for this server. Follow the same steps above and specify VSAN0002 as FC network because this FCOE connection will be mapped to second VC module for SAN Fabric B. Users then need to type in storage array port WWPN connecting to SAN Fabric B and BFS LUN ID. Click Add to create second FCOE connection and back to server profile creation window. Page 54

55 Verify the connections just created. Scroll down to the rest of server profile configuration. Optionally set Local Storage policy below. Page 55

56 SAN Storage is application after OneView integration with HP 3PAR storage array. In this case, we ll not define this option. Users can optionally to use mouse drag/drop to change boot order. In this case, we ll move PXE and Hard Disk boot ahead of Floppy and USB. Page 56

57 Optionally, users can change server BIOS settings. In this case, we ll check the option and click Edit BIOS settings. Scroll down until Power Management Options. Page 57

58 In this case, we ll change HP Power profile from default balanced power to Maximum Performance. Click OK to finish BIOS configuration. Page 58

59 Review server profile configuration Page 59

60 Optionally users can click bottom left setting button to review what has changed in the profile configuration. After verifying configuration, click Create to apply the profile to the server blade. Some settings like Firmware, BIOS and local storage policy will cause server to boot into embedded Intelligent Provisioning to configure server to match the profile configuration. Page 60

61 After profile is created, verify the connection status and optionally users can select Actions->Launch Control to open HP ILO remote console. Users may get an installation message for remote console software installation or users can use Jave plug-in console. Page 61

62 Sample ILO remote console window will look like the following. Users can optionally create a profile template using a working server profile and leave the template as unassigned so it can be copied into individual profile and applied to the rest of server blades. Select a working profile and select Actions->Copy. Page 62

63 Give the template profile a name and select Unassigned for server hardware and click Create. Review the server profile template just created. Page 63

64 Firmware Repository: The HP OneView appliance ships with a default SPP that contains the necessary firmware to successfully import and manage an enclosure. It is unnecessary to upload an SPP into the appliance. Optionally you can upgrade a newer or custom version of SPP into OneView if needed. From top level menu, select Firmware Bundles : Examine the bundled SPP baseline package inside OneView appliance and select top left Add Firmware Bundle : Drag and drop your SPP file into the upload window: Page 64

65 Upload progress will be displayed upon user confirmation. After successful import the new SPP file, users will have the option to select which SPP to use when importing or upgrading enclosure, Virtual Connect module and server firmware. Licensing By default, OneView installation will include 60-day trial license. During this evaluation period, HP OneView will not enable ilo Advanced features or functionality. The ILO Advanced license (trial or retail) is also required for server and enclosure power and performance monitoring. To add OneView license, please select Settings from drop down menu. Inside Setting view, click Overview link: Page 65

66 From the dropdown menu, scroll down and select Licenses : Select Add to add the new OneView License. Cut and paste license key into pop up dialog window: Page 66

67 Verify the number of licenses available associated with the license key. REST API and PowerShell Library HP OneView appliance is based on Rest API and the API could be accessed by http web operation, Python and PowerShell language. The HP OneView PowerShell Library source code and installer are available for download at The following samples demonstrate HP OneView cmdlets. [HPONEVIEW]: Not Connected PS C:..\WindowsPowerShell\v1.0> Connect-HPOVMgmt cmdlet Connect-HPOVMgmt at command pipeline position 1 Supply values for the following parameters: (Type!? for Help.) appliance: User: Administrator Password: ******** [HPONEVIEW]: Administrator@ PS C:..\WindowsPowerShell\v1.0> Get-HPOVNetwork -report Ethernet Networks Name VLAN ID Purpose Typical Bandwidth Max Bandwidth Smartlink Private Network Status VLAN125-MGMT General True False OK VLAN125-MGMT General True False OK VLAN160-VMotion General True False OK VLAN160-VMotion General True False OK Page 67

68 VLAN161-NFS General True False OK VLAN161-NFS General True False OK VLAN162-Data General True False OK VLAN162-Data General True False OK VLAN163-Data General True False OK VLAN163-Data General True False OK VLAN164-Data General True False OK VLAN164-Data General True False OK FC Networks Name Fabric Type Uplink Bandwidth Link Stability Time (sec) Auto Login Redistribution Status VSAN0001 FabricAttach Auto 30 True OK VSAN0002 FabricAttach Auto 30 True OK [HPONEVIEW]: PS C:..\WindowsPowerShell\v1.0> gcm -Name "New-hpov*" CommandType Name ModuleName Function New-HPOVAddressRange HPOneView Function New-HPOVBackup HPOneView Function New-HPOVEnclosure HPOneView Function New-HPOVEnclosureGroup HPOneView Function New-HPOVLdap HPOneView Function New-HPOVLdapGroup HPOneView Function New-HPOVLdapServer HPOneView Function New-HPOVLicense HPOneView Function New-HPOVLogicalInterconnectGroup HPOneView Function New-HPOVNetwork HPOneView Function New-HPOVNetworkSet HPOneView Function New-HPOVPowerDevice HPOneView Function New-HPOVProfile HPOneView Function New-HPOVProfileConnection HPOneView Function New-HPOVResource HPOneView Function New-HPOVRestore HPOneView Function New-HPOVServer HPOneView Function New-HPOVSupportDump HPOneView Function New-HPOVUnmanagedDevice HPOneView Function New-HPOVUplinkSet HPOneView Function New-HPOVUser HPOneView Page 68

69 Virtual Connect FlexFabric-20/40 F8 Module After going over the typical OneView set up procedures, it s important to share more detailed information on Virtual Connect FlexFabric-20/40 F8 module. 16 Internal 1/10/20GE Ports to Server Bays SFP+ FlexPorts (1/10GE or 2/4/8G FC) X1 X2 X3 X4 UID HP VC FlexFabric- 20/40 F8 Module Q1 Q2 Q3 Q4 PID X1 X5 X2 X6 X3 X7 X4 X8 X L/A Paired Paired Reset X10 Q1 Q2 Q3 Q4 Ports and Port Numbering 4 QSFP+ Ports 4x40GE or 16x10GE X5 X6 X7 X8 SFP+ Paired FlexPorts SFP+ Paired FlexPorts (1/10GE or 2/4/8G FC) 2x20GE Internal Stacking The HP Virtual Connect FlexFabric 20/40 F8 Module has 4x40G QSPF+ and 8x1/10G SFP+ Ethernet or 2/4/8GB FC interfaces as uplink ports. For the downlink ports, you have 16x10/20Gb Ethernet links towards HP BladeSystem C7000 server bays with a single downlink to a server support up to 3 FlexNICs and 1 FlexHBA or 4 FlexNICs. A FlexHBA can be configured to transport either FCOE or Accelerated iscsi. The 4xQSFP port numbers start with Q1.1 and end with Q4.4. If you decide to leverage a breakout cable you will have 4 10Gb ports per QSFP slot so Q1.1 through Q1.4 would be available for 10Gb. If a 40Gb QSFP is placed in Q1 then Q1.1 will appear as populated and port Q1.2-Q1.4 will be unavailable. Below is an example of how a 40Gb port would appear in OneView with the 20/40 Module. Page 69

70 The 8xSFP+ port numbers start from X1 and end with X8. These ports can accommodate 1/10Gb Ethernet or 2/4/8GB FC connections. Below you can see a variety of different connections options and how they would appear in OneView include FC, Ethernet, and stacking between Virtual Connect Modules. Ports X5-X6 and X7-X8 are called paired ports and each paired port can be set to Ethernet or Fiber Channel but mixing of both traffic types in the same paired set is not allowed. An example of a configuration that would not be allowed is putting a 10Gb Ethernet in port X7 and then trying to enable Fiber Channel on port X8. However, you could have FCOE on port X8 because it would be running at 10Gb. You cannot mix 1Gb and 10Gb on the same paired port set as well. They are paired in terms of internal clocking source but there is no performance penalty by using paired ports comparing with individual ports X1-X4. Ports X9 and X10 are dedicated internal horizontal cross-connects which provide 2x20Gb connectivity. Server Port/MAC/WWPN Mapping Through the OneView Interconnect view, users can get information on how FlexFabric - 20/40 F8 Module internal downlink server ports are mapped to server CNA MAC/WWPN addresses. Page 70

71 Page 71

72 OneView Final Config with Virtual Connect FlexFabric-20/40 F8 Module After getting familiar with the general OneView setup flow and VC FF-20/40 F8 hardware, users can check the following sections for final OneView Configuration corresponding to networking, SAN Fabric and server profiles. The following capture shows OneView LAN and SAN uplink configurations for VC FF-20/40 F8 module. Users can focus on VC FF20/40 F8 modules in I/O bay 3 and 4 and uplink ports and definitions highlighted in colors. VC FF 10Gb/24-Port modules in I/O bay 1 and 2 are for other testings. VC FF-20/80 F8 in I/O Bay 3: X1, X2: 8G FC ports using VSAN-01 FC Uplink Set to connect with Brocade X5, X6: 10G Ethernet ports using VC-1-Uplink Ethernet Uplink Set to connect with Nexus X7: VC vertical stacking to VC FF 10Gb/24-Port module in I/O Bay 1, a requirement if multiple VC modules inside one enclosure. Not needed if only two VC modules in one enclosure X9, X10: 2x20G internal horizontal stacking links between VC modules. VC FF-20/80 F8 in I/O Bay 4: X1, X2: 8G FC ports using VSAN-02 FC Uplink Set to connect with Brocade X5, X6: 10G Ethernet ports using VC-2-Uplink Ethernet Uplink Set to connect with Nexus X7: VC vertical stacking to VC FF 10Gb/24-Port module in I/O Bay 2, a requirement if multiple VC modules inside one enclosure. Not needed if only two VC modules in one enclosure X9, X10: 2x20G internal horizontal stacking links between VC modules. Networking Uplinks Configuration to Nexus 5672 The following captures verified module serial number so users can relate LLDP connectivity with networking team. Page 72

73 The following capture verified Virtual Connect uplink port LLDP neighbor information. Page 73

74 The following capture shows the first VC FF-20/40 F8 module LACP uplink configuration corresponding to vpc port-channel 101 on both switches. Page 74

75 The following capture shows the second VC FF-20/40 F8 module LACP uplink configuration corresponding to vpc port-channel 102 on both switches. Page 75

76 SAN Uplinks Configuration to Brocade 6510 The following capture shows two VC FF-20/40 F8 modules with uplink connectivity. The very right column is VC module uplink port PWWN and the column to the left is logged-in Brocade switch NWWN (verified by switchshow command on Brocade). Page 76

77 The following two captures show Virtual Connect internal SAN Fabric configuration. Note: The field of Associate with SAN is related with Brocade Network Advisor (BNA) and OneView integration. We ll cover this field in more details in the later section of OneView/3PAR/BNA integration. Users can ignore this field if not using Brocade BNA integration. Page 77

78 The following captures display the two SAN fabric uplink configuration for Virtual Connect. Page 78

79 Server Downlink Network Set Configuration The following shows two network sets definition ready to be assigned to the server downlinks. Note: We changed Max bandwidth value from 10Gb to 20Gb as one server has HP FlexFabric 20Gb 630M adapter (Broadcom based). Page 79

80 Server Profile Configuration The following capture displays the blade server profile definition for LAN and SAN connectivity. The step by step profile configuration is covered in previous initial OneView setup section. Page 80

81 HP 3PAR StoreServ 7400 Infrastructure Deployment 3PAR StoreServ product lines are HP flagship storage array offering ONE Architecture from midrange to high-end storage arrays. Currently product offering includes mid-range 7200, 7400(2-Node and 4-Node), 7450 All-Flash array and high end and series. Users can manage all products using the same CLI and GUI interface. HP 3PAR offers many advanced features for VMware virtualization including wide striping, mesh-active clustered architecture, hardware assisted support of VMware VAAI, Thin Provisioning technologies, Dynamic and Adaptive Optimization, Priority Optimization, and HP 3PAR Recovery Manager for VMware. With latest OneView 1.10 and OneView for vcenter 7.4.1, users can manage features like volume creation and exporting in OneView and vcenter directly. 3PAR StoreServ 7400 Hardware Overview Node Enclosure HP 3PAR StoreServ 7400 system offer 2-node and 4-node configurations. We used Node system in the setup. The HP 3PAR StoreServ 7200 and 7400 controller enclosures hold up to 24, 2.5 inch SFF SAS disk drives arranged, vertically in a single row at the front of the enclosure (numbered 0 to 23). The following picture shows the font and back picture of Node configuration. The port numbers are marked for easier identification when users cable and configure the storage system. HP 3PAR StoreServ Node System (2U) Back CAUTION 764W PCM Disconnect all power for complete isolation 1 MGMT RC-1 FC-1 FC-2 DP-2 HP 3PAR 7400 DP UID Intr :3:1 1:1:2 1:0:2 1:0:1 1:1:1 Intr 0 1:2:1 1:2:2 1:2:3 1:2:4 PCI-HBA Mfg 1 CAUTION 764W PCM Disconnect all power for complete isolation Disconnect all power for complete isolation 0 Mfg PCI-HBA 0:2:1 0:2:2 0:2:3 0:2:4 Intr 0 Intr 1 DP-1 HP 3PAR :0:1 0:0:2 DP-2 0:1:1 0:1:2 FC-1 FC-2 0:3:1 MGMT RC-1 0 Disconnect all power for complete isolation CAUTION 764W PCM UID CAUTION 764W PCM HP 3PAR StoreServ Node System (2U 24xSFF) Front PAR StoreServ 7400 The heart of node system is the 7000 controller node and the following picture shows the port layout details. Page 81

82 Drive Enclosure The base node enclosure can be linked up with multiple disk enclosures. The storage system can include the following types of drive enclosures: The HP M6710 Drive Enclosure (2U24) holds up to 24, 2.5 inch small form factor (SFF) Serial Attached SCSI (SAS) disk drives, arranged vertically in a single row at the front of the enclosure (numbered 0 to 23). The HP M6720 Drive Enclosure (4U24) holds up to 24, 3.5 inch large form factor (LFF) SAS disk drives, arranged horizontally with four columns of six disk drives at the front of the enclosure (numbered 0 to 23). We used M6710 SFF drive enclosure in the testing and the following is the front and back picture of the M6710 drive enclosure. Users can verify the node and drive enclosure summary using showcage command. DIA-3PAR-01 cli% showcage Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side 0 cage0 1:0:1 0 0:0: DCN1 n/a Page 82

83 1 cage1 1:0:1 4 0:0: DCS2 n/a 2 cage2 1:0:1 3 0:0: DCS2 n/a 3 cage3 1:0:1 2 0:0: DCS2 n/a 4 cage4 1:0:1 1 0:0: DCS2 n/a 5 cage5 1:0:2 3 0:0: DCS2 n/a 6 cage6 1:0:2 2 0:0: DCS2 n/a 7 cage7 1:0:2 1 0:0: DCS2 n/a 8 cage8 1:0:2 0 0:0: DCS2 n/a DCN1 is a Node cage with 2 nodes and up to 24 SFF (Small Form Factor) drives. DCS1 is a M6720 Drive chassis with up to 24 LFF (Large Form Factor) drives. DCS2 is a M6710 Drive chassis with up to 24 SFF (Small Form Factor) drives. Enclosure Cabling To cable node enclosure with multiple drive enclosures, users should following 3PAR cabling guide. There are multiple cabling guides depending on node and drive enclosure models. The following diagram is from 2-node System with the M6710 SFF drive enclosures. HP 3PAR Service Processor The HP 3PAR Service Processor (SP) software is available in both physical and virtual versions. The SP is designed to provide remote error detection, and reporting and to support diagnostic and maintenance activities involving the HP 3PAR Storage system. The data collected by the SP is used to maintain, troubleshoot, and upgrade the SP and HP 3PAR Storage system at the customer s operating site. The SP software is built on top of a Linux distribution. The physical SP is a hardware device mounted in the rack of HP 3PAR Storage system. If the customer chooses a physical SP, each storage system installed at the operating site includes a physical SP installed in the same cabinet as the system s controller nodes. Page 83

84 The HP 3PAR Virtual Service Processor is deployed as a virtual machine (VM). The VSP is provided in an Open Virtual Format (OVF) for VMware vsphere Hypervisor and self-extractable virtual hard disk (VHD) package for Microsoft Hyper-V. Storage System and Service Processor Initialization Users should follow HP 3PAR StoreServ 7000 Storage Installation Guide for initial installation task. Service processor is an integral process during the initial setup process. More detailed information on Service Processor setup is discussed in HP 3PAR Service Process User Guide. The following captures display service processor GUI interface. Page 84

85 HP also offers SmartStart software to help users streamline the setup of new service processors and storage systems. Page 85

86 Please see HP 3PAR StoreServ 7000 Storage SmartStart Software User Guide for more details on initial configuration of the system. 3PAR StoreServ 7400 Software Configuration An HP 3PAR storage system is composed of the following logical data layers: Page 86

87 Physical Drives are divided in Chunklets (E-, F-, S- and T-Class: 256MB; 7000 and 10000: 1GB) Logical Disks: Collections of chunklets which are arranged as rows of RAID sets. LDs are automatically created when required and provide the space for Virtual Volumes, Snapshot and Logging Disks Common Provisioning Groups (CPG): User created virtual pools of Logical Disks that allocates space to virtual volumes on demand. The CPG defines RAID level, drive type and number, striping pattern etc. Virtual Volumes (VV) Exported LUNs: User created fat or thin provisioned volumes composed of LDs according to the specified CPG policies. User exports VV as LUN 3PAR can be configured by 3PAR Manage Console GUI or CLI. A typical 3PAR configuration flow is as below. Page 87

88 The fabric facing ports should be defined to gain fabric access to Brocade 6510 switches. The ports should be defined be defined as Host for Connection Mode and Point for Connection Type. In our setup, Node 0 controller 0:2:3 and Node 1 controller 1:2:3 are connecting with Brocade for SAN Fabric A access. Node 0 controller 0:2:4 and Node 1 controller 1:2:4 are connecting with Brocade for SAN Fabric B access. Page 88

89 To create a host, we can select left panel Hosts menu and right click Hosts entry and select Create Host. Page 89

90 We should give a host name and select OS type. For 3PAR, Persona type 11=VMware is automatically assigned to the host after we select OS type as ESX 4.x/5.x. Page 90

91 In the next screen, we can choose available WWNs logged into 3PAR from Brocade fabric if the servers have booted up and Brocade has the right zoning in place. If OneView has pre-populated server WWPN from profile, users can manually type or cut/paste server HBA WWPNs in OneView profile to define the host. Note: To manually type or cut/paste server WWPN, input the value without : character. Page 91

92 For volume creation, first we need to decide which Common Provisioning Groups (CPG) the volume should be based on. CPG is the policy container where users define RAID policy and drive type along with optionally advanced parameters like striping pattern. Users can check existing pre-defined CPG under Provisioning->CPG section. If needed, users can define their own CPG by right click CPG and choose Create CPG. Page 92

93 For CPG creation, users will need to provide CPG name and select Device Type and Raid Type and optionally check Show Advanced Options to adjust other advanced settings. Note: Because the way 3PAR internal Chunklets are built across disks, RAID 1, 5 and 6 are essentially RAID 10, 50 and 60. Page 93

94 With CPGs ready to be used by virtual volumes, we can create any new virtual volumes by right clicking Create Virtual Volume as the capture below displayed. Page 94

95 Users will need to provide the volume size and thin/thick provisioning for space allocation and the most importantly, which CPG the volume should be based on. Optionally users can choose same or different CPG to store COPY, which are snapshots of this virtual volume. Page 95

96 After the virtual volume is created, users can export the volume to the host or host set by selecting Export option. Page 96

97 Users then will choose from hosts or host set to export this volume to. Users can manually choose LUN ID or choose Auto option. Page 97

98 Users can verify the volume export status from Hosts entry or Virtual Volume entry. 3PAR CLI can be also used for various operations such as display virtual volumes and their export status. DIA-3PAR-01 cli% showvv ----Rsvd(MB) (MB)-- Id Name Prov Type CopyOf BsId Rd -Detailed_State- Adm Snp Usr VSize <output truncated> 32 C Blade4-ESXi-Boot tpvv base RW normal <output truncated> Page 98

99 DIA-3PAR-01 cli% showvlun -v C Blade4-ESXi-Boot Active VLUNs Lun VVName HostName -Host_WWN/iSCSI_Name- Port Type Status ID 0 C Blade4-ESXi-Boot c blade4 1000CE160F :2:3 host active 1 0 C Blade4-ESXi-Boot c blade4 1000CE160F :2:4 host active 1 0 C Blade4-ESXi-Boot c blade4 1000CE160F :2:3 host active 1 0 C Blade4-ESXi-Boot c blade4 1000CE160F :2:4 host active total VLUN Templates Lun VVName HostName -Host_WWN/iSCSI_Name- Port Type 0 C Blade4-ESXi-Boot c blade host total DIA-3PAR-01 cli% showhost c blade4 Id Name Persona -WWN/iSCSI_Name- Port 10 c blade4 VMware 1000CE160F :2:4 1000CE160F :2:3 1000CE160F :2:3 1000CE160F :2:4 Page 99

100 vsphere 5.5 Infrastructure Host Networking Configuration The following captures shows a typical vswitch configuration corresponding to the server discussed in the previous sections. Virtual Connect also fully supports VMware vds and other vswitch solutions like Cisco Nexus 1000v. For NIC teaming, Virtual Connect supports default teaming policy and other advanced policy like load-based teaming method in vds. Virtual Connect does NOT support LACP or link channeling teaming policy. Users can optionally config jumbo frame on VMkernal interface and Nexus switches. Virtual Connect always have jumbo frame of 9K bytes enabled by default. The following captures can verify NIC physical MAC address and it s corresponding OneView profile port address. Page 100

101 Host Storage Configuration We can see the VMware host have 2 FCOE HBAs installed and their WWPN/WWNN are matching OneView Profile definition. Note: Broadcom NetXtreme II adapter may not have FCOE enabled by default in ESXi. HP adapters based on the chipset are Flexfabric 630, 534 cards and possibly any other cards with the digit 3 in the middle of HP card model number. Please follow this VMware KB article to enable the FCOE offload capacity of the adapter. So far the host can only see the private 5G BFS LUN. Page 101

102 We can manually create another LUN for this blade for testing. After rescanning the storage connectivity on the host, the 15G LUN showed up in the host and is ready for datastore provisioning. HP 3PAR Storage SATP and PSP setting For 3PAR storage provision in VMware environment, users can review the following documentations for design and recommendation under HP Enterprise Information Library : HP 3PAR StoreServ Storage best practices guide HP 3PAR StoreServ Storage and VMware vsphere 5 best practices HP 3PAR VMware ESX Implementation Guide Page 102

103 As users can see from the screen capture right above this section, a 3PAR LUN will be discovered by default as VMW_SATP_ALUA and use Most Recent Used as PSP policy. 3PAR recommends using PSP Round Robin policy and changed default Round Robin new path selection rule from 1000 IOPS to 1 IOPS. Users can automate the above operation by using the following ESXCLI operation to add a custom VMware NMP rule by matching 3PAR vendor name and model number. ~ # esxcli storage nmp satp rule add --satp="vmw_satp_alua" --psp="vmw_psp_rr" -- vendor="3pardata" --model="vv" --psp-option="iops=1" --claim-option="tpgs_on" -- description="hp 3PAR Custom Rule" ~ # ~ # The following screen capture verifies the new rule has been created. This rule will be used for newly discovered 3PAR LUN. For existing LUNs already discovered as MRU PSP policy, users can issue a reclaim operation in ESXCLI storage section or reboot the host for the new rule to take effect. The following capture verifies the original MRU rule and the new RR rule after LUN reclaim. ~ # esxcli storage nmp device list --device=naa.60002ac adec naa.60002ac adec Device Display Name: 3PARdata Fibre Channel Over Ethernet Disk (naa.60002ac adec) Storage Array Type: VMW_SATP_ALUA Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{tpg_id=1,tpg_state=ao}} Path Selection Policy: VMW_PSP_MRU Path Selection Policy Device Config: Current Path=vmhba33:C0:T0:L1 Path Selection Policy Device Custom Config: Working Paths: vmhba33:c0:t0:l1 Is Local SAS Device: false Is Boot USB Device: false ~ # ~ # ~ # ~ # esxcli storage core claiming reclaim --device=naa.60002ac adec ~ # ~ # ~ # esxcli storage nmp device list --device=naa.60002ac adec naa.60002ac adec Device Display Name: 3PARdata Fibre Channel Over Ethernet Disk (naa.60002ac adec) Storage Array Type: VMW_SATP_ALUA Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{tpg_id=1,tpg_state=ao}} Path Selection Policy: VMW_PSP_RR Path Selection Policy Device Config: {policy=rr,iops=1,bytes= ,useano=0; lastpathindex=0: NumIOsPending=0,numBytesPending=0} Path Selection Policy Device Custom Config: Working Paths: vmhba32:c0:t0:l1, vmhba32:c0:t1:l1, vmhba33:c0:t1:l1, vmhba33:c0:t0:l1 Is Local SAS Device: false Is Boot USB Device: false ~ # Page 103

104 HP 3PAR VAAI Plugin for ESXi 5.x With HP 3PAR MU1 and ESXi 5.5, 3PAR VAAI primitives are handled by the default T10 VMware plug-in and users do not require to install any HP 3PAR VAAI plug-in. For VAAI requirements of earlier versions of ESXi and 3PAR OS, please check HP 3PAR VMware ESX Implementation Guide for more details. ~ # esxcli storage core device vaai status get naa.60002ac adec VAAI Plugin Name: ATS Status: supported Clone Status: supported Zero Status: supported Delete Status: supported naa.60002ac adec VAAI Plugin Name: ATS Status: supported Clone Status: supported Zero Status: supported Delete Status: supported Storage Connectivity Verification We used VMware IO Analyzer to create some random IO flows to test 3PAR and Virtual Connect active/active forwarding for a given LUN matching VMware Round Robin PSP policy. Page 104

105 On 3PAR, users can easily monitor I/O through GUI with several mouse clicks and also from CLI directly. Page 105

106 DIA-3PAR-01 cli% statport 12:54:42 09/27/2014 r/w I/O per second KBytes per sec Svt ms IOSz KB Port D/C Cur Avg Max Cur Avg Max Cur Avg Cur Avg Qlen 0:0:1 Data t :0:2 Data t :1:1 Data t :1:2 Data t :2:1 Data t :2:2 Data t :2:3 Data t :2:4 Data t :0:1 Data t :0:2 Data t :1:1 Data t :1:2 Data t :2:1 Data t :2:2 Data t :2:3 Data t :2:4 Data t Data t Press the enter key to stop... Page 106

107 HP OneView Integration with HP 3PAR and Brocade Network Advisor for Auto Volume Creation and Zoning We have going through the typical VMware server/storage provisioning in previous sections. With the HP OneView 1.10 release, users can provision 3PAR volume and host creation and export as well as Brocade zoning automatically by integrating 3PAR and Brocade Network Advisor. This section will go through the end to end process on how users can configure and leverage this functionality. HP OneView with 3PAR StoreServe Integration 3PAR Configuration Before configuring OneView to connect with 3PAR management interface, we need to first enable 3PAR WebAPI and CIM services. To start 3PAR web API and CIM services, please use the following commands and users can check 3PAR Command Line Interface Reference for more details. DIA-3PAR-01 cli% startwsapi WSAPI Server is already Enabled. DIA-3PAR-01 cli% startcim CIM server will start in about 90 seconds DIA-3PAR-01 cli% showwsapi -Service- -State- -HTTP_State- HTTP_Port -HTTPS_State- HTTPS_Port -Version- Enabled Active Disabled 8008 Enabled DIA-3PAR-01 cli% showcim -Service- -State- --SLP-- SLPPort -HTTP-- HTTPPort -HTTPS- HTTPSPort PGVer CIMVer Enabled Active Enabled 427 Enabled 5988 Enabled OneView Configuration After verifying the services are started on 3PAR side, we can select Storage Systems in OneView. Click Add Storage System Page 107

108 We need to provide 3PAR IP address and credential to login. After authentication, OneView should retrieve the storage system information and we need to select Add Storage Pools Page 108

109 The available storage pools from 3PAR will be displayed for users to add into OneView. The storage pool term is OneView corresponds to 3PAR Common Provisioning Group (CPG) concept and users should see the same set of CPG lists under 3PAR management console. Page 109

110 Users should map OneView Virtual Connect fabric definition to remote 3PAR target ports. In this setup, we know Virtual Connect VSAN0001 FC fabric is connected with Brocade and then 3PAR port 0:2:3 and 1:2:3. Virtual Connect VSAN0002 FC fabric is connected with Brocade and then 3PAR port 0:24 and 1:2:4 Please make sure you select the right mapping per your physical connectivity. The following capture verifies the imported 3PAR 7400 system. Page 110

111 We can review the imported storage pools(cpg in 3PAR term) by selecting Storage Pools section. Review the available CPG definitions. Optionally we can select any CPG not being imported previously. Page 111

112 Optionally, we can choose to create a volume definition template to simplify the future volume creation in OneView. In the template, we can define the CPG, Think/Thick provisioning, private/shared and the size of the volume. Page 112

113 Users must create a volume in OneView before add this volume in OneView Server profile. The same volume name will show up in 3PAR GUI/CLI after creation. We can select Volumes menu as below. Select Create Volume. Page 113

114 In volume creation window, we can manually define size, thin/thick reservation and etc or select a template defined previously so these settings can populate automatically. In the following example, we created a 10G shared volume. We can review the volume just created in the overview section. We can also see the same volume created in 3PAR OS. Please note, the volume export host list is empty as we only created a volume in OneView/3PAR without adding this volume to any OneView profile so this volume is not exported to any host. Page 114

115 This above process finishes the initial 3PAR import process. If users don t have Brocade SAN switch or Brocade Network Advisor, they can add this volume into OneView profile shown in the following section. However, we d like to test Brocade Network Advisor integration so we ll cover BNA integration first before applying this volume into profile. Page 115

116 HP OneView with Brocade Network Advisor Integration Brocade Network Advisor is Brocade s core management software to help users proactively manage end-to-end network health, performance and aids troubleshooting. Administrators can quickly identify network issues with customizable dashboards and drill-down to isolate and fix problems. Network Advisor supports the entire Brocade IP and SAN portfolio, for unified network visibility and control. Brocade Network Advisor Configuration Users can get access to the software from Brocade account teams or download BNA software through Brocade web site given the right access level. Users should have a windows server reserved for the software installation. Please check Brocade documentation for detailed H/W and S/W requirement for the server. Full-featured BNA is a licensed product to support end to end Brocade fabric monitoring. However, if users are only interested with this particular OneView with BNA integration, the installation process should give users an option to install SMI agent only, which is a free sub-service for BNA software. After BNA installation process, users should continue with Discover Fabric and provide two 6510 switch IP address and login credentials so BNA can discover existing SAN fabric. Page 116

117 Optionally, users can login to BNA to view dashboard and switch SAN configuration and status. Page 117

118 To integrate with HP OneView, users need to assure that SMI agent is enabled with default port number. If port number is changed for SMI agent in BNA, users also need to change on OneView side to match in later steps. To confirm SMI status, please select Network Advisor Configuration. One of steps is to enable SMI agent with the port number. Page 118

119 Users can verify windows server is listening on default port 5989 and check the process ID associated with it. C:\Users\Administrator>netstat -o -n -a find "5989" TCP : :0 LISTENING 6536 TCP : :52855 ESTABLISHED 6536 C:\Users\Administrator>tasklist /fi "PID eq 6536" Image Name PID Session Name Session# Mem Usage ========================= ======== ================ =========== ============ cimomsrv.exe 6536 Services 0 356,812 K OneView Configuration After we finished BNA setup, we can select OneView SAN Managers to import BNA. Select Add SAN Manager. Provide BNA IP address, port number and login credential. Page 119

120 Verify discovered BNA and its associated SAN fabric. Next we need to go back to OneView Network configuration and select two VSAN network we created earlier and select the right Virtual Connect FC fabric with Brocade FC Switching fabric in Associated with SAN field. This will enable Brocade SAN fabric automatically zoning. Page 120

121 Provisioning host LUN with 3PAR Auto Export and Brocade Auto Zoning With both 3PAR and BNA integration steps complete, now it s time to prove this end to end host LUN provisioning. We ll select the previous blade server as the first time, we ll edit its profile and enable SAN storage with ESXi host type and click Add volume. Page 121

122 In the pop-up window, we select the previous created volume blade4-san-volume-1 and click Add. Verify the volume information in profile page. Apply the profile and profile status should change to Configure SAN storage. Note: You don t need to power down server for SAN volume provisioning. Page 122

123 After provisioning, we can see blade4-san-volume-1 has been exported automatically by 3PAR to this blade. Users can verify the LUN is accessible in vsphere web client. The above process is a good start but if you have noticed, C blade4 host has been manually created in 3PAR and manually zoned in Brocade 6510s. Now let s verify to provision the same shared volume with another ESXi blade server which has not been configured in 3PAR and Brocade switches. We ll edit blade server 10 profile and add the same blade4-san-volume-1 to this blade. The reason this blade can see the same volume is that in OneView, we originally set this volume as shared volume. Page 123

124 After server profile is applied, we can see the following Brocade 6510 captures, OneView and BNA automatically created zoning for this blade to the target 3PAR ports. DIA-BSAN-01:FID3:admin> zoneshow <output truncated> zone: FF2040Bay10_1000CE160F90001C 10:00:ce:16:0f:90:00:1c 20:23:00:02:ac:00:ad:ec 21:23:00:02:ac:00:ad:ec <output truncated> DIA-BSAN-02:FID128:admin> zoneshow <output truncated> zone: FF2040Bay10_1000CE160F90001E 10:00:ce:16:0f:90:00:1e 21:24:00:02:ac:00:ad:ec 20:24:00:02:ac:00:ad:ec <output truncated> On 3PAR side, we can see a new host was created with the host name as the same as OneView profile name. Page 124

125 And this same volume is exported to both hosts at the same time. On blade 10 host, we can verify the LUN was discovered correctly. Page 125

126 Page 126

127 HP OneView and 3PAR StoreServ Integration with VMware vcenter With HP advanced integration with 3PAR and Brocade, users can provision VMware infrastructure more easily. At the same time, OneView for vcenter (OV4VC) enables VMware admins to manage and provisioning HP server and storage infrastructure without leaving vcenter console. HP OneView for VMware vcenter integrates the manageability features of HP OneView, HP ProLiant servers, HP BladeSystem and HP Storage into the VMware vcenter console. HP OneView for VMware vcenter Includes support for the following components: HP OneView for VMware vcenter Server module Adds HP ProLiant and HP BladeSystem hardware monitoring into the HP OneView for vcenter console. Provides server hardware management capabilities, including comprehensive monitoring, firmware update, vsphere 5.x/ESXi 5.x image deployment, remote control, end-to-end monitoring for Virtual Connect, and power optimization for HP servers in the VMware environment. The Server module is not required for RMV installation. HP OneView for VMware vcenter StoreFront Module Provides storage configuration and status information for mapping VMs, datastores, and hosts to LUNs on HP storage arrays. The Storage Module enables you to register HP Storage arrays and use the VASA provider. Supports provisioning on HP 3PAR StoreServ, HP StoreVirtual, HP MSA, and HP EVA storage systems. Supported provisioning tasks include creating, expanding, or deleting a datastore, and creating or cloning a VM. Displays view-only information for the HP StoreOnce Backup systems. HP 3PAR Recovery Manager for vcenter Installs RMV plugin with vsphere Client and vsphere Web Client integration. The OneView for vcenter software can be downloaded at HP OneView Partner Integrations. For detailed documentations, please check HP Enterprise Information Library and select HP Insight Management->HP OneView for VMware vcenter. HP OneView for VMware vcenter Installation Guide HP OneView for VMware vcenter User Guide Software Installation A windows server should be reserved for the software installation and please check the above installation guide for the details. The software is downloaded as an.exe file format. During the installation process, users need to provide vcenter address and login credential. Note: It s extremely important to make sure DNS lookup/reverse lookup for OV4VC server, OneView server and vcenter server. Many of internal communications between the servers are based on hostname instead of DNS. Without DNS implementation, some communications will be broken and unstable. Page 127

128 Storage Administrator Portal Configuration After the installation of server and storage module, users need to login to OV4VC storage administrator portal (by clicking its desktop icon) and import 3PAR storage. The login credential should be your vcenter login credential. At the following screen, users can click Add to import any storage array. Page 128

129 Select 3PAR as storage type. Provide 3PAR storage system address and login credential to import the array. vsphere Web Client Configuration After finishing the installation and the storage administrator portal configuration. Users can login to vcenter to provide some credentials for OV4VC server module such as OA, ilo and ESXi login and OneView login information. Users should see the HP Page 129

130 Management Administrator blue icon at the bottom. User can click HP Management Administration icon to view OV4VC get started page. Provide ESXi, ilo and OA login credential. Since we are using OneView to manage Virtual Connect, we can leave Virtual Connect Username and Virtual Connect Password fields empty. They are for legacy Virtual Connect Manager. We manage Virtual Connect through OneView credentials in the following steps. After finishing this tab, we can click the tab of Credentials for HP Management Software Integration. Page 130

131 Provide OneView ip address and login information. We also provide HP Insight Control Server Provisioning (ICSP) credential here to provision host OS through ICSP. We ll cover more ICSP details in the following sections. Page 131

132 Storage Administrator Portal tab can let us view-only information for the previous 3PAR storage information. Additional privilege could be setup for this tab and users can check OV4VC installation guide for more details. HP Infrastructure Management After finishing setting up all credentials for inter-communications, users can go to vcenter home page and click HP Infrastructure icon at the Inventory section. Page 132

133 We can see the HP enclosure and 3PAR info from vcenter, Host Networking Management Network Diagram With OV4VC, users can gain much more visibility for HP servers providing vsphere infrastructure environment. Users can select any ESXi host and select Manage->HP Management->Networking->Network Diagram to see the visual mapping between ESXi Page 133

134 vswitch/vds, Virtual Connect and TOR switch level. Users can save the topology map in PNG image format. Page 134

135 Network Detail The purpose of Network Detail tab is to help users to configure their vswitch/vds according to OneView server profile configuration. Before using this function, users will have to understand OneView profile networking configuration and manually created mapping VSS/VDS config on vsphere side. The configuration on this tab is optional. Without it, vsphere hosting can be still configured using the method described above. However, if customers want to leverage HP Grow Cluster function inside OV4VC to automatically do ESXi OS deployment on servers and add servers in the vsphere cluster. This tab needs to be set up ahead of time and that will lead us to an important concept inside this tab called Reference host. The concept of Reference host has similarity of vsphere Host Profile. The purpose of the reference host for OV4VC is to set one host inside a cluster as a baseline host in regard to OneView profile networking and vsphere host networking configuration. OV4VC will compare the select host to the reference host in regard to OneView profile configuration to see if they have the same networking config, if they do, the compliance status for Server Profile Status. Then OV4VC will compare this host OneView Profile networking config with its local VSS/VDS configuration to see if they are matching and if not, OV4VC will list the recommended config changes to users and if users choose to mitigate this inconsistence, users will select Apply recommendations button and OV4VC will start to configure VSS/VDS to match its recommendation. If the action is successful, Host Network Status compliance status should turn. To prepare setting up this tab, users need to first label their networks in related to VMkernel network in OneView Network configuration so OV4VC will understand which vlan is for host VMkernal and which vlan is for VM data traffic. Even after finishing the above OneView Network config, the page will still show every field as? mark to indicate that the OV4VC doesn t have enough information to make recommendation. Page 135

136 The next step we need to do is to select a host as reference host and click Set Reference Host as below in that specific host. After the above step, the Server Profile Status should turn green assuming hosts OneVew networking config is consistent with the reference host OneView networking config. We can also see the listed recommended actions for OV4VC to change VSS/VDS to make it consistent with the OneView profile networking config. If users choose to apply the recommended actions by clicking Apply Recommended Actions and confirming it, the OV4VC will start to make a change on vsphere VSS/VDS side. Page 136

137 Note: The host will be put into maintenance mode and OV4VC will require all VMs to be evacuated from this host in order to make the change. Without meeting the above requirement, OV4VC will fail the task and display the failure reason in its Tasks history. After finishing the task, the Host Network Status field will turn green and the Host Network Configuration Status will turn green as well. The Host Network Configuration Status naming may be confusing, its status is just the combination of the status of both Server Profile Status (OneView profile networking config) and Host Network Status (vsphere VSS/VDS config). Page 137

138 If we review VSS/VDS configuration, we can see its configuration has been changed to match OV4VC recommendations. Users can review the above task history in OV4VC tasks window. Page 138

139 Users can also view additional information in vcenter Tasks window. HP Storage Management OV4VC storage module provides detailed information in vcenter for users to view their HP Storage information Page 139

140 Like host networking, storage module also provides the visual mapping between virtual machine disks and their datastore path information like below. Users can even create datastore inside vcenter using OV4VC. This will be discussed more in later sections. Host Operation Management Inside HP Management tab, users can also hover the mouse over OV icon and select Server Profile to have a separate web page launched into OneView profile definition for this particular host. Page 140

141 Hover the mouse over ilo icon will give users links for ilo services such as Remote Console. Page 141

142 Users can view detailed HP firmware/driver information under Software/Firmware tab. Users have the option to upgrade host firmware inside vcenter. Page 142

143 Page 143

144 OneView for vcenter and Insight Control Server Provisioning Grow ESXi Cluster When OneView for vcenter working together with HP Insight Control Server Provisioning (ICSP), these two products offer a powerful solution inside vcenter where users can select new/unused Proliant servers and ICSP will automatically provision user selected ESXi OS image to the servers and OV4VC will then add the provisioned servers into the existing cluster. Corresponding OneView profiles for these new servers will also be created in OneView. The deployment process is driven by a wizard where users only need to provide some basic information and login credentials. Before we dive into the whole process, it s important for users to have a basic understanding on HP Insight Control Server Provisioning product. HP Insight Control Server Provisioning Insight Control server provisioning is a virtual appliance used to install and configure HP ProLiant servers. Insight Control server provisioning uses resources such as OS Build Plans and scripts to run deployment jobs. IC server provisioning allows you to: Install Windows, Linux, and ESXi on ProLiant servers Deploy operating systems to Virtual Machines (VMs) Update drivers, utilities, and firmware on ProLiant servers using the HP Service Packs for ProLiant (SPPs) Configure ProLiant system hardware, ilos, BIOS, HP Smart Array and Fibre Channel HBA Deploy to target servers with or without using PXE (for HP ProLiant Gen8 servers or later. You can do PXE-less deployment on these servers without any special configuration because they come with built-in service OSs as part of the embedded intelligent provisioning feature) Run deployment jobs on multiple servers simultaneously Customize your ProLiant deployments via an easy to use browser-based interface Create and run customized Build Plans to perform additional configuration tasks either before or after OS deployment Migrate from HP Insight Control server deployment (RDP) to Insight Control server provisioning. The in-depth discussion of ICSP architecture and deployment is out of the scope of this paper but we d like to have some quick start information for users below. ICSP can be downloaded from Insight Control Server Provisioning product page. ICSP user guide and technical white papers can be found at HP Enterprise Information Library. In the main portal, users should follow HP Insight Management->HP Insight Control link. The following and other guides are available. HP Insight Control Server Provisioning Technology White Paper HP Insight Control Server Provisioning 7.3 Update 2 Online Help HP Insight Control Server Provisioning 7.3 Update 2 Installation Guide HP Insight Control Server Provisioning 7.3 Update 2 Administrator Guide HP Insight Control Server Provisioning 7.3 Update 2 Build Plans Reference Guide HP Insight Management 7.3 Update 2 Support Matrix The following are some ICSP quick start information. The ICSP itself is installed in vcenter as ova/ovf format. Page 144

145 ICSP virtual appliance needs another separate windows or Linux server as its media server to hold all OS images. For windows media server, users can login from the server into ICSP appliance and download a setup utility exe file on desktop and use its wizard to streamline media server installation. Page 145

146 The following is the supported OS images for ICSP After media server is setup, users should provide media server IP address, directory and credentials for ICSP so the virtual appliance can establish communication with the media server. To start with server OS provisioning, users need to add candidate servers from Servers menu. Page 146

147 Servers have to be discovered by ICSP in order to execute the OS deployment job. There are two ways for ICSP to discover servers. Servers traditional PXE booting into ICSP The DHCP server in customer networks can point ICSP appliance as PXE server so servers can start communication with ICSP in or the appliance to inject a small service OS into server ProLiant Gen8 and later servers can optionally be added into ICSP using server ilo address (PXE-less provisioning) ProLiant Gen8 and later servers have built-in Intelligent Provisioning service OS. ICSP can directly communicate with the service OS through ilo port and provision OS even without PXE network infrastructure. To add a ProLiant Gen8 and later server by ilo, users need to provide ilo IP address and login credential. After the server is added, we can see the server status. Server state is UNREACHABLE just means the server is not in Maintenance mode where service OS is loaded into memory. Service OS in server memory is in charge of communicating with ICSP for OS provisioning. The server is in this state because in the previous step, we advise ICSP not to boot the server into maintenance mode. The next step is to run an OS Build Plan on this server. Users can click Actions menu in this server and select Run OS Build Plans Page 147

148 Click Add to add a new build plan for this server. Select the OS you want to deploy and click Add and click OK to confirm OS deployment. Then ICSP will try to boot server into maintenance OS and use server service OS to communicate for the OS deployment. Page 148

149 The nature of a build plan is a collection of pre-defined scripts like the following. Users have the options to change script parameters or create their own build plans. The above steps summarized to add a server by ilo. To add servers by PXE, users will need to configure the network DHCP server to PXE boot server into ICSP and the server will show up in Servers list. ICSP has a built-in DHCP server which users can optionally enable it. If users want to use existing DHCP server, some configuration will be needed on DHCP server to point PXE server as ICSP virtual appliance, users can check more details in HP Insight Control Server Provisioning 7.3 Update 2 Installation Guide. The following is the configuration highlights for MS DHCP server definition Page 149

150 The following capture shows the DHCP server settings for ICSP in our setup. Insight Control Server Provisioning Custom Build Plan Users have the option to create their own OS build plan. The typical process is to make a copy of ICSP built-in build plan and make the relevant changes over it. For OneView for vcenter HP Grow Cluster to work, Users need to create a custom build plan based on ICSP default ESXi5.5 build plan. The details on how to create this build plan is described in HP OneView for VMware vcenter User Guide Appendix B. The key of this custom build plan is to insert the following scripts into kickstart file. <output truncated> # Set the network to DHCP on the network adapater network --bootproto=dhcp ## IC4VC custom values %firstboot VMNIC=$(esxcli network nic list grep awk -F " " '{ print $1 }') esxcli network vswitch standard uplink remove --uplink-name=vmnic0 --vswitch-name=vswitch0 esxcli network vswitch standard uplink add --uplink-name=$vmnic --vswitch-name=vswitch0 esxcli network ip interface ipv4 set --interface-name=vmk0 --ipv4=@ip_address@ -- netmask=@net_mask@ --type=static esxcli network ip route ipv4 add --network default esxcli network ip dns server remove --server "" -a esxcli network ip dns server add esxcli network ip dns server add esxcli system hostname set # If vlan tagging is not used then vlan_id value should be 0 # A vlan_id of 0 disables vlan_tagging in ESX and causes Mgmt to use interface of vswitch esxcli network vswitch standard portgroup set --portgroup-name "Management Network" services.sh restart ## post-install script <output truncated> Note: If you want to cut/paste the above scripts from OV4VC user guide, please make sure the option --type=static is in the same line as the previous esxcli network ip interface ipv4 set command. OneView for vcenter HP Grow Cluster With users have a basic understand of Insight Control Server provisioning, now we can go ahead to test OneView for vcenter HP Grow Cluster function. To get this step to work, there are several prerequisites need to be met. Page 150

151 ICSP and DHCP servers are set up as the previous section OV4VC server module configuration management tab has the valid ICSP IP address and login credential Existing ESXi cluster need to have a host set up as OV4VC Reference host in vcenter Management->HP Management- >Networking->Network Details. On ICSP, we need to create a custom build plan described in previous section. To start to grow ESXi cluster, please select the ESXi cluster we d like to expand and right click cluster entry. Choose second entry for advanced deployment. Page 151

152 OV4VC will communicate with OneView and return any available servers which don t have any profile assigned yet. In our example, we have 2 new blades 10 and 11. Page 152

153 Select the custom build plan we created in the previous section. Select the two hosts we want to deploy ESXi image and add to this cluster. Page 153

154 Provide some TCP/IP information including static IP for the hosts. Note: ESXi root password can be copied down using the small green arrow to the right. Review the confirmation page and confirm to deploy hosts. Page 154

155 A pop-up window will confirm OV4VC starts to execute grow cluster function. We can monitor the progress in HP Management->Tasks panel, notice the progress below indicated that right now OneView is creating server profiles for two blades. Page 155

156 Users can monitor server profile creation process in the OneView window at the same time. Server booting process can be monitored in ilo remote console window. We should see the servers are PXE booted into ICSP appliance. Both servers should eventually booted into Maintenance Mode Page 156

157 At this moment, we can monitor ICSP server status and both servers show up in ICSP servers list. Page 157

158 After ICSP injects service OS into the servers, the build plan will continue to deploy ESXi images into servers. ICSP provision job status for this deployment should eventually succeed. vcenter cluster should have two hosts added into the cluster in the maintenance mode so OV4VC can provision VSS according to reference host configuration. Page 158

159 The newly created host should have the same configuration as the reference host. the new hosts s VSS should be configured the same as reference hosts as well. Page 159

160 Page 160

161 OneView for vcenter End to End Datastore Provisioning Another powerful feature of OneView for vcenter with 3PAR/OneView integration is that users can create a datastore for the entire cluster without leaving vcenter. The vcenter datastore creation wizard only takes a few mouse clicks but at the background, OV4VC finishes all of the following without users manual provisioning. OneView to attach SAN volume in server profile 3PAR to create hosts, volume and export the volume to the hosts Brocade SAN fabric for auto zoning vcenter cluster remote LUN access and create the user-defined datastore To use this feature, we can first select the cluster we want to create the datastore and select All HP Management Actions-> HP Create Datastore. Select the cluster we want to create datastore. Page 161

162 Define the number of capacity of the datastore and which 3PAR Common Provision Group the volume will be based on. Provide the name of the datastore. Page 162

163 Confirm the policy defined previously and Finish. After the process finishes, we can se on 3PAR, the two hosts were automatically created matching the two ESXi hosts in the cluster. Page 163

164 One volume was created and exported to the two ESXi hosts. In OneView, both hosts profiles have a new SAN storage volume provisioned. Page 164

165 On both Brocade 6510s, both SAN fabrics finished auto zoning for the two ESXi hosts. DIA-BSAN-01:FID3:admin> zoneshow <output truncated> zone: Bay10_148c01b52ff_100012D0BDD0003C 10:00:12:d0:bd:d0:00:3c 20:23:00:02:ac:00:ad:ec 21:23:00:02:ac:00:ad:ec zone: DemoBrocade_host12_100012D0BDD0006C 10:00:12:d0:bd:d0:00:6c 20:23:00:02:ac:00:ad:ec 21:23:00:02:ac:00:ad:ec <output truncated> DIA-BSAN-02:FID128:admin> zoneshow <output truncated> zone: Bay10_148c01b52ff_100012D0BDD0003E 10:00:12:d0:bd:d0:00:3e 21:24:00:02:ac:00:ad:ec 20:24:00:02:ac:00:ad:ec zone: DemoBrocade_host12_100012D0BDD0006E 10:00:12:d0:bd:d0:00:6e 21:24:00:02:ac:00:ad:ec 20:24:00:02:ac:00:ad:ec <output truncated> To delete the datastore, we can use HP Delete Datastore menu. Page 165

166 After confirmation, the datastore/lun will be deleted at ESXi level, OneView profile will remove the SAN volume related to this datastore in server profiles, 3PAR will delete hosts and volume created and finally Brocade will remove the auto zoning created. Page 166

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Technical white paper vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma, HP DCA Table of contents Introduction...

More information

FCoE Cookbook for HP Virtual Connect

FCoE Cookbook for HP Virtual Connect Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs

More information

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

VersaStack for Data Center Design & Implementation (VDCDI) 1.0 VersaStack for Data Center Design & Implementation (VDCDI) 1.0 COURSE OVERVIEW: VersaStack for Data Center Design and Implementation (VDCDI) is a four-day training program. The Cisco-IBM VersaStack validated

More information

Implementing Multi-Chassis Link Aggregation Groups (MC-LAG)

Implementing Multi-Chassis Link Aggregation Groups (MC-LAG) Implementing Multi-Chassis Link Aggregation Groups (MC-LAG) HPE Synergy Virtual Connect SE 40Gb F8 Module and Arista 7050 Series Switches Technical white paper Technical white paper Contents Introduction...

More information

HP Discover 2013 HOL 2653 HP Virtual Connect 4.01 features and capabilities. Lab Guide

HP Discover 2013 HOL 2653 HP Virtual Connect 4.01 features and capabilities. Lab Guide HP Discover 2013 HOL 2653 HP Virtual Connect 4.01 features and capabilities Lab Guide HP Virtual Connect 4.01 features and capabilities Lab Guide Rev. 1.1 Copyright 2013 Hewlett-Packard Development Company,

More information

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This

More information

Cisco Actualtests Questions & Answers

Cisco Actualtests Questions & Answers Cisco Actualtests 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 22.8 http://www.gratisexam.com/ Sections 1. Questions 2. Drag & Drop 3. Hot Spot Cisco

More information

Page 2

Page 2 Page 2 Mgmt-B, vmotion-a vmotion-b VMM-Pool-B_ Connection-B -Set-A Uplink-Set-A Uplink-Set-B ACI-DC Standard Aggregation L3 Switch Configuration for existing Layer 2 : Nexus 6K-01 switch is

More information

FC Cookbook for HP Virtual Connect

FC Cookbook for HP Virtual Connect Technical white paper FC Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements January 206 Table of contents Change History 7 Abstract 8 Considerations and concepts 9 VC SAN module descriptions

More information

UCS Engineering Details for the SAN Administrator

UCS Engineering Details for the SAN Administrator UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want

More information

HPE OneView 4.0 User Guide

HPE OneView 4.0 User Guide HPE OneView 4.0 User Guide Abstract The User Guide is intended for administrators who are using the HPE OneView appliance graphical user interface or REST APIs to manage IT hardware in a converged infrastructure

More information

HP Virtual Connect for c-class BladeSystem Setup and Installation Guide

HP Virtual Connect for c-class BladeSystem Setup and Installation Guide HP Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.01 Abstract This document contains setup, installation, and configuration information for HP Virtual Connect. This document

More information

Cirrus Data Migration with the INFINIDAT InfiniBox Array in a Brocade FC SAN, FOS 8.0.1b

Cirrus Data Migration with the INFINIDAT InfiniBox Array in a Brocade FC SAN, FOS 8.0.1b VALIDATION TEST REPORT Cirrus Data Migration with the INFINIDAT InfiniBox Array in a Brocade FC SAN, FOS 8.0.1b Supporting Fabric OS 8.0.1b 53-1004964-01 27 January 2017 2017, Brocade Communications Systems,

More information

Cisco ACI with Cisco AVS

Cisco ACI with Cisco AVS This chapter includes the following sections: Cisco AVS Overview, page 1 Cisco AVS Installation, page 6 Key Post-Installation Configuration Tasks for the Cisco AVS, page 43 Distributed Firewall, page 62

More information

Deploying VMware vsphere 6.0 with HPE BladeSystem, HPE OneView, Cisco Nexus, and NetApp FAS

Deploying VMware vsphere 6.0 with HPE BladeSystem, HPE OneView, Cisco Nexus, and NetApp FAS Deploying VMware vsphere 6.0 with HPE BladeSystem, HPE OneView, Cisco Nexus, and NetApp FAS Last Updated: 5/17/2016 Technical white paper Contents Introduction... 3 Solution Overview... 3 Data Core Networking...

More information

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2. UCS-ABC Why Firefly Length: 5 Days Format: Lecture/Lab Course Version: 5.0 Product Version: 2.1 This special course focuses on UCS Administration and Troubleshooting UCS Manager 2.0 and provides additional

More information

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels Configuring Virtual Port Channels This chapter describes how to configure virtual port channels (vpcs) on Cisco Nexus 5000 Series switches. It contains the following sections: Information About vpcs, page

More information

HPE OneView SCVMM Integration Kit (v 3.0) User Guide

HPE OneView SCVMM Integration Kit (v 3.0) User Guide HPE OneView SCVMM Integration Kit (v 3.0) User Guide Abstract This guide is intended for system administrators who use the HPE OneView SCVMM Integration Kit (v 3.0) and other Hewlett Packard Enterprise

More information

HPE OneView 3.1 User Guide

HPE OneView 3.1 User Guide HPE OneView 3.1 User Guide Abstract The User Guide is intended for administrators who are using the HPE OneView appliance graphical user interface or REST APIs to manage IT hardware in a converged infrastructure

More information

Cisco Exam Questions & Answers

Cisco Exam Questions & Answers Cisco 642-995 Exam Questions & Answers Number: 642-995 Passing Score: 800 Time Limit: 120 min File Version: 36.9 http://www.gratisexam.com/ Exam Code: 642-995 Exam Name: Unified Computing Troubleshoot

More information

MDS 9020 Switch Interoperability

MDS 9020 Switch Interoperability CHAPTER 10 This chapter describes how to connect the Cisco MDS 9020 fabric switch to a third-party switch, and it includes the following sections: Specifications, page 10-5 Expected Topology Behavior,

More information

HPE OneView for VMware vcenter Release Notes (8.2 and 8.2.1)

HPE OneView for VMware vcenter Release Notes (8.2 and 8.2.1) HPE OneView for VMware vcenter Release Notes (8.2 and 8.2.1) Abstract This document describes changes in HPE OneView for VMware vcenter to help administrators understand the benefits of obtaining the 8.2

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels This chapter contains the following sections: Information About vpcs, page 1 Guidelines and Limitations for vpcs, page 10 Configuring vpcs, page 11 Verifying the vpc Configuration, page 25 vpc Default

More information

HP StorageWorks Fabric OS 6.1.2_cee1 release notes

HP StorageWorks Fabric OS 6.1.2_cee1 release notes HP StorageWorks Fabric OS 6.1.2_cee1 release notes Part number: 5697-0045 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Copyright 2009 Brocade

More information

FlexPod Express with VMware vsphere 5.1u1 Implementation Guide

FlexPod Express with VMware vsphere 5.1u1 Implementation Guide Technical Report FlexPod Express with VMware vsphere 5.1u1 Implementation Guide Karthick Radhakrishnan, Arvind Ramakrishnan, Lindsey Street, NetApp Jeffrey Fultz, Cisco March 2014 TR-4261 TABLE OF CONTENTS

More information

HPE OneView 3.1 Support Matrix

HPE OneView 3.1 Support Matrix HPE OneView 3.1 Support Matrix Abstract This document lists the hardware, firmware, and software requirements for installing and using HPE OneView on a virtual machine host. Part Number: 5200-1774e Published:

More information

HP Virtual Connect: Common Myths, Misperceptions, and Objections, Second Edition

HP Virtual Connect: Common Myths, Misperceptions, and Objections, Second Edition HP Virtual Connect: Common Myths, Misperceptions, and Objections, Second Edition A technical discussion of common myths, misperceptions, and objections to the deployment and use of HP Virtual Connect technology

More information

HP0-S21. Integrating and Managing HP BladeSystem in the Enterprise. Download Full Version :

HP0-S21. Integrating and Managing HP BladeSystem in the Enterprise. Download Full Version : HP HP0-S21 Integrating and Managing HP BladeSystem in the Enterprise Download Full Version : http://killexams.com/pass4sure/exam-detail/hp0-s21 Question: 165 You are setting up a new infiniband network

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

Active System Manager Release 8.2 Compatibility Matrix

Active System Manager Release 8.2 Compatibility Matrix Active System Manager Release 8.2 Compatibility Matrix Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Fibre Channel Zoning

Fibre Channel Zoning Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre

More information

Configuring Fibre Channel Interfaces

Configuring Fibre Channel Interfaces This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is

More information

HP ProLiant blade planning and deployment

HP ProLiant blade planning and deployment HP ProLiant blade planning and deployment Chris Powell CSG Products, Services, and Solutions Training Hewlett-Packard 2004 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

Cisco Nexus 1100 Series Virtual Services Appliances

Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Version 1.0 June 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.

More information

HPE OneView 3.0 User Guide for HPE Synergy

HPE OneView 3.0 User Guide for HPE Synergy HPE OneView 3.0 User Guide for HPE Synergy Abstract This guide describes HPE OneView features, interfaces, resource model design, and secure working environment. It describes up-front planning considerations

More information

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary

More information

HP OneView 1.20 User Guide

HP OneView 1.20 User Guide HP OneView 1.20 User Guide Abstract This guide describes HP OneView features, interfaces, resource model design, and secure working environment. It describes up-front planning considerations and how to

More information

HPE Virtual Connect 4.62 Release Notes

HPE Virtual Connect 4.62 Release Notes HPE Virtual Connect 4.62 Release Notes Abstract This document provides Virtual Connect release information for version 4.62. This document supersedes the information in the documentation set released with

More information

Cisco MDS 9000 Family Blade Switch Solutions Guide

Cisco MDS 9000 Family Blade Switch Solutions Guide . Solutions Guide Cisco MDS 9000 Family Blade Switch Solutions Guide Introduction This document provides design and configuration guidance for administrators implementing large-scale blade server deployments

More information

LAN Ports and Port Channels

LAN Ports and Port Channels Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,

More information

VMware Cloud Foundation (VCF) Certification on HPE Synergy

VMware Cloud Foundation (VCF) Certification on HPE Synergy VMware Cloud Foundation (VCF) Certification on HPE Synergy Best practices and general build information for VCF 2.3.2 use on HPE Synergy platform Technical white paper Technical white paper Contents Introduction

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE Design Guide APRIL 0 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

Technical Brief: How to Configure NPIV on VMware vsphere 4.0

Technical Brief: How to Configure NPIV on VMware vsphere 4.0 Technical Brief: How to Configure NPIV on VMware vsphere 4.0 Provides step-by-step instructions on how to configure NPIV on VMware vsphere 4.0 in a Brocade fabric. Leveraging NPIV gives the administrator

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels This chapter contains the following sections: Information About vpcs vpc Overview Information About vpcs, on page 1 Guidelines and Limitations for vpcs, on page 11 Verifying the vpc Configuration, on page

More information

Administering VMware vsphere and vcenter 5

Administering VMware vsphere and vcenter 5 Administering VMware vsphere and vcenter 5 Course VM-05 5 Days Instructor-led, Hands-on Course Description This 5-day class will teach you how to master your VMware virtual environment. From installation,

More information

Cisco Nexus 1000V on HP BladeSystem

Cisco Nexus 1000V on HP BladeSystem Cisco Nexus 1000V on HP BladeSystem An informational guide for optimal VMware vsphere design using HP BladeSystem (w/virtual Connect) and Cisco Nexus network infrastructure Table of contents Overview...

More information

COMPANY X PROOF-OF- CONCEPT LAB FOR THE DELL M1000E CHASSIS

COMPANY X PROOF-OF- CONCEPT LAB FOR THE DELL M1000E CHASSIS COMPANY X PROOF-OF- CONCEPT LAB FOR THE DELL M1000E CHASSIS Victor Lama Dell Fabric Specialist Banking and Securities 05 July 2011 This document contains a high-level overview of Fibre Channelover-Ethernet

More information

Host and storage system rules

Host and storage system rules Host and storage system rules Host and storage system rules are presented in these chapters: Heterogeneous server rules on page 185 MSA storage system rules on page 235 HPE StoreVirtual storage system

More information

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group 2 UCS Bundled Upgrades Useful for Staging, Labs, and Non Productions This does a very quick fast upgrade

More information

HP OneView for VMware vcenter User Guide

HP OneView for VMware vcenter User Guide HP OneView for VMware vcenter User Guide Abstract This document contains detailed instructions for configuring and using HP OneView for VMware vcenter (formerly HP Insight Control for VMware vcenter Server).

More information

Cisco HyperFlex Systems

Cisco HyperFlex Systems White Paper Cisco HyperFlex Systems Converting to Cisco Nexus 1000V Distributed Switches for Cisco HyperFlex Virtual Machine Guest and VMware vmotion Networks Author: Hui Chen October 2016 2016 Cisco and/or

More information

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60

HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 HPE Virtual Connect for c-class BladeSystem Setup and Installation Guide Version 4.60 Abstract This document contains setup, installation, and configuration information for HPE Virtual Connect. This document

More information

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4)

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4) Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4) First Published: April 17, 2015 Last Modified: August 27, 2015 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San

More information

Emulex Universal Multichannel

Emulex Universal Multichannel Emulex Universal Multichannel Reference Manual Versions 11.2 UMC-OCA-RM112 Emulex Universal Multichannel Reference Manual Corporate Headquarters San Jose, CA Website www.broadcom.com Broadcom, the pulse

More information

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.

More information

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo Vendor: EMC Exam Code: E20-002 Exam Name: Cloud Infrastructure and Services Exam Version: Demo QUESTION NO: 1 In which Cloud deployment model would an organization see operational expenditures grow in

More information

HP OneView for VMware vcenter User Guide

HP OneView for VMware vcenter User Guide HP OneView for VMware vcenter User Guide Abstract This document contains detailed instructions for configuring and using HP OneView for VMware vcenter (formerly HP Insight Control for VMware vcenter Server).

More information

HP OneView 1.05 User Guide

HP OneView 1.05 User Guide HP OneView 1.05 User Guide Abstract This guide describes HP OneView features, interfaces, resource model design, and secure working environment. It describes up-front planning considerations and how to

More information

Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator

Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator Version 2.3.0 Note Before using this information and the product it supports, read the general and

More information

Configuring and Managing Virtual Storage

Configuring and Managing Virtual Storage Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

UCS deployment guide for Nimble Storage

UCS deployment guide for Nimble Storage Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine

More information

Discover 2013 HOL2653

Discover 2013 HOL2653 Discover 2013 HOL2653 HP Virtual Connect 4.01 features and capabilities Steve Mclean and Keenan Sugg June 11 th to 13 th, 2013 AGENDA Schedule Course Introduction [15-20 Minutes] Introductions and opening

More information

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check

More information

HP BladeSystem Networking Reference Architecture

HP BladeSystem Networking Reference Architecture HP BladeSystem Networking Reference Architecture HP Virtual Connect FlexFabric Module and VMware vsphere 5 Technical white paper Table of contents Executive Summary... 2 Virtual Connect FlexFabric Module

More information

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Technical Marketing Solutions Guide Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Document Revision Date Revision Description (author) 5/16/2014 1. 0 Draft release (mmclaughlin)

More information

HP StoreOnce Recovery Manager Central for VMware User Guide

HP StoreOnce Recovery Manager Central for VMware User Guide HP StoreOnce Recovery Manager Central 1.2.0 for VMware User Guide Abstract The guide is intended for VMware and database administrators who are responsible for backing up databases. This guide provides

More information

HPE OneView for VMware vcenter User Guide

HPE OneView for VMware vcenter User Guide HPE OneView for VMware vcenter User Guide Abstract This document contains detailed instructions for configuring and using HPE OneView for VMware vcenter. It is intended for system administrators who are

More information

Cisco HyperFlex Systems

Cisco HyperFlex Systems White Paper Cisco HyperFlex Systems Install and Manage Cisco HyperFlex Systems in a Cisco ACI Environment Original Update: January 2017 Updated: March 2018 Note: This document contains material and data

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.   Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 642-999 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest

More information

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum White Paper FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum February 2017 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page

More information

DCNX5K: Configuring Cisco Nexus 5000 Switches

DCNX5K: Configuring Cisco Nexus 5000 Switches Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco

More information

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Cisco Nexus 4000 Series Switches for IBM BladeCenter Cisco Nexus 4000 Series Switches for IBM BladeCenter What You Will Learn This document is targeted at server, storage, and network administrators planning to deploy IBM BladeCenter servers with the unified

More information

Cisco Nexus 1000V InterCloud

Cisco Nexus 1000V InterCloud Deployment Guide Cisco Nexus 1000V InterCloud Deployment Guide (Draft) June 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 49 Contents

More information

Active System Manager Version 8.0 User s Guide

Active System Manager Version 8.0 User s Guide Active System Manager Version 8.0 User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

A. Both Node A and Node B will remain on line and all disk shelves will remain online.

A. Both Node A and Node B will remain on line and all disk shelves will remain online. Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in

More information

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Dell Networking Solutions Engineering July 2011 A Dell EMC Deployment and Configuration Guide Revisions Date Description

More information

Pass-Through Technology

Pass-Through Technology CHAPTER 3 This chapter provides best design practices for deploying blade servers using pass-through technology within the Cisco Data Center Networking Architecture, describes blade server architecture,

More information

Dell EMC. VxBlock and Vblock Systems 350 Administration Guide

Dell EMC. VxBlock and Vblock Systems 350 Administration Guide Dell EMC VxBlock and Vblock Systems 350 Administration Guide Document revision 1.10 June 2018 Revision history Date Documen t revision Description of changes June 2018 1.10 Changed the following sections

More information

FlexPod Express with VMware vsphere 6.0: Small and Medium Configurations

FlexPod Express with VMware vsphere 6.0: Small and Medium Configurations NetApp Verified Architecture FlexPod Express with VMware vsphere 6.0: Small and Medium Configurations Authors: Karthick Radhakrishnan and Arvind Ramakrishnan, NetApp Reviewers: Jeffrey Fultz and Chris

More information

VMware vsphere with ESX 6 and vcenter 6

VMware vsphere with ESX 6 and vcenter 6 VMware vsphere with ESX 6 and vcenter 6 Course VM-06 5 Days Instructor-led, Hands-on Course Description This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere

More information

Oracle Database Consolidation on FlashStack

Oracle Database Consolidation on FlashStack White Paper Oracle Database Consolidation on FlashStack with VMware 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 18 Contents Executive Summary Introduction

More information

Configuring Service Profiles

Configuring Service Profiles Configuring Service Profiles This chapter includes the following sections: Service Profiles that Override Server Identity, page 1 Service Profiles that Inherit Server Identity, page 2 Service Profile Templates,

More information

FASTER AND MORE EFFICIENT FLEX SYSTEM MANAGEMENT WITH LENOVO XCLARITY ADMINISTRATOR VS. HP ONEVIEW

FASTER AND MORE EFFICIENT FLEX SYSTEM MANAGEMENT WITH LENOVO XCLARITY ADMINISTRATOR VS. HP ONEVIEW FASTER AND MORE EFFICIENT FLEX SYSTEM MANAGEMENT WITH LENOVO XCLARITY ADMINISTRATOR VS. HP ONEVIEW Time savings are important for your IT staff: less time to complete management tasks, such as configuring

More information

Configuring Virtual Port Channels

Configuring Virtual Port Channels This chapter contains the following sections: Information About vpcs, page 1 Guidelines and Limitations for vpcs, page 10 Verifying the vpc Configuration, page 11 vpc Default Settings, page 16 Configuring

More information

Questions & Answers

Questions & Answers 642-999 Questions & Answers Number: 642-999 Passing Score: 800 Time Limit: 90 min File Version: 36.6 http://www.gratisexam.com/ 642-999 Questions & Answers Exam Name: Implementing Cisco Data Center Unified

More information

Cisco CCIE Data Center Written (Beta) Download Full Version :

Cisco CCIE Data Center Written (Beta) Download Full Version : Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs

More information

Service Profiles and Templates

Service Profiles and Templates Service Profile Templates, page 1 Service Profiles, page 3 Service Profile Templates Service profile templates enable you to quickly create several service profiles with the same basic parameters, such

More information

CCIE Data Center Written Exam ( ) version 1.0

CCIE Data Center Written Exam ( ) version 1.0 CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data

More information

Question: 1 Which methods can an administrator implement to provide higher security within a management network? (Select two.)

Question: 1 Which methods can an administrator implement to provide higher security within a management network? (Select two.) Volume: 104 Questions Question: 1 Which methods can an administrator implement to provide higher security within a management network? (Select two.) A. SNMPV3 B. community settings C. NTP D. isolated VLAN

More information

Active System Manager Release 8.2 Installation Guide

Active System Manager Release 8.2 Installation Guide Active System Manager Release 8.2 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites

More information

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Technical Deep Dive: Getting to the Heart of the Matter UCS Technical Deep Dive: Getting to the Heart of the Matter Session ID Agenda Introductions UCS Architecture, Innovations, Topology Physical Building Blocks Logical Building Blocks Typical Use Cases (Live

More information

A Dell Interoperability Whitepaper Victor Teeter

A Dell Interoperability Whitepaper Victor Teeter Deployment of Dell M8024-k Blade Switch with Cisco Nexus 5000 Series Switch A Dell Interoperability Whitepaper Victor Teeter THIS TECHNICAL INTEROPERABILITY WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY,

More information

Configuring EtherChannels

Configuring EtherChannels CHAPTER 11 This chapter describes how to configure EtherChannels and to apply and configure the Link Aggregation Control Protocol (LACP) for more efficient use of EtherChannels in Cisco NX-OS. This chapter

More information

NS0-171.network appliance

NS0-171.network appliance NS0-171.network appliance Number: NS0-171 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator is deploying a FlexPod solution for use with VMware vsphere 6.0. The storage environment

More information

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

DSI Optimized Backup & Deduplication for VTL Installation & User Guide DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:

More information

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections: This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page

More information