MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1)

Size: px
Start display at page:

Download "MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1)"

Transcription

1 5 CHAPTER MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) This chapter describes how to set up a basic dual-core topology with an MDS 9000 switch configured for interop mode 1 and a McData 6064 switch. Devices are connected to both core switches and all traffic must flow through both cores to reach its destination. This chapter includes the following sections: Specifications, page 5-1 Expected Topology Behavior, page 5-2 Configuration, page 5-3 Verification, page 5-7 Zoning, page 5-15 Specifications The following switches and code levels were used for this example configuration: MDS 9509 running NX-OS Release 5.2(1) McData 6064 Version Figure 5-1 shows the topology used for this example configuration. 5-1

2 Expected Topology Behavior Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Figure 5-1 MDS 9509 Switch and McData Switch Dual Core Topology Target JBOD VZ1 Host /31 1/37 13/ Cisco MDS 9513 McData Gigabit ISLs Note The VZ1 JBOD is an arbitrated loop with 12 drives. Expected Topology Behavior This section covers the Fibre Channel services and features that act differently in this topology (Figure 5-1) as compared to a homogeneous, single-vendor implementation. It contains the following topics: Zoning, page 5-2 FSPF, page 5-3 Trunking and PortChannels, page 5-3 Domain IDs, page 5-3 Zoning In the core-core topology, zone members are all pwwns, because the McData domain/port nomenclature is not a valid form according to the FC standard. When a zone set activation is made at one core switch, the zone set activation is sent to the other core switch. Either core switch may make zoning changes and have them be propagated to the other core switch. 5-2

3 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Configuration Both core switches provide all of the zone security for the device-attached ports because the Cisco MDS 9000 switch and the McData switches do not check the source and destination of the frame when traversing E ports. The Cisco MDS 9000 switch only provides hardware-enforced security on the ingress ports to the fabric, while the McData switch only provides soft zoning. Note After two active zone sets successfully merge, always copy the active zone set to the full zone set database prior to modifying it on the Cisco MDS 9000 switch. FSPF All links within the topology show the link cost of 500, because the McData 6064 switch used in this example only supports 2 Gbps. The McData switches load balance their routes using source/destination; the ingress edge switch uses the same ISL for all traffic that has the same source/destination pair. If the McData switch can load balance using source/destination/ox-id, then it can choose either of the ISLs for the route through the fabric. The MDS switch continues to load balance across ISLs using source/destination/ox-id of the frame. Trunking and PortChannels The lack of MDS 9000 switch-to-mds 9000-switch connections prohibits the topology from containing TE ports or PortChannels. Only standard E ports are used for the ISLs. Domain IDs The domain IDs are limited to the 97 to 127 range due to a restriction imposed by McData's inability to handle IDs outside of that range. While the MDS 9000 switch can handle domain IDs outside of this range in its normal mode of operation, the implementation of interoperability mode includes this limitation. Domain ID modifications can be handled in two ways, disruptively or nondisruptively: Disruptive This event impacts the entire switch. When changing domain IDs, McData requires the entire switch to be taken offline and/or rebooted. Nondisruptive This event is limited to the VSAN where the event is taking place. Only the MDS 9000 switch can perform this action, as the domain manager process for this VSAN is restarted and not the entire switch. This restart requires any device logged into the VSAN to log into the fabric again to obtain a new FC ID. Configuration This section describes the configuration process and includes the following topics: Configuring the McData 6064 Switch, page 5-4 Configuring the MDS 9000 Switch, page

4 Configuration Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Configuring the McData 6064 Switch In this example, the McData 6064 switch is configured for interop mode using Telnet and the CLI. The switch is placed in an offline state, the default zone is set to deny, the domain ID is set to 0x61 (97), and timers are altered to match the fabric. To configure the McData 6064 switch, follow these steps: Step 1 Step 2 Display current switch information. Root> show switch State: Online R_A_TOV: 100 <=== must match other fabric switches E_D_TOV: 20 <=== must match other fabric switches Preferred Domain ID: 2 Domain ID Offset: 96 Switch Priority: Never Principal Speed: 2 Gb/sec Rerouting Delay: Interop Mode: McDATA Fabric 1.0 <=== McData Fabric mode Active Domain ID: 2 World Wide Name: 10:00:08:00:88:A0:7A:74 Insistent Domain ID: Domain RSCN: Zoning RSCN: FC Address Domain: 62 (hex) Limited Fabric RSCN: Zone FlexPars: Fabric Filtering RSCN Zone Isolation: Fabric Filtering Safe Zoning: ISL FSPF Cost: By Port Speed Web : Frame Resize State: Block Dup WWN State: API : API Management IP: Password Exp. Time: 0 Alter the timers, RA_TOV and ED_TOV, if needed. These options are listed in the config switch menu. Root> config switch Config.Switch>.. - Move back one level FrameResizeState - Set the FRAME_RESIZE enabled state RSCNZoneIsolation - Set the RSCN Zone Isolation state apistate - Set the api enabled state banner - Configure the banner blockdupwwn - Set Block duplicate WWN state commadelim - Toggle comma-delimited display mode domainidoffset - Set the domain ID offset for the switch domainrscn - Set the switch state for generation of domain RSCN's edtov - Set the E_D_TOV for the switch insistdomainid - Set the Insistent domain ID state for the switch interopmode - Set the Interoperability mode for the switch islfspfcost - Sets the FSPF cost of ISLs login - Login to CLI under different access rights logout - Logout of CLI ltdfabrscn - Set the switch state for limiting Fabric RSCN's prefdomainid - Set the preferred domain ID for the switch priority - Set the switch priority ratov - Set the R_A_TOV for the switch reroutedelay - Enable or disable the reroute delay 5-4

5 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Configuration root safezoning setipv6 show speed webstate zoneflexpars zoningrscn - Move back to root level - Set the fabric state for prohibiting Default Zoning - Sets the enabled state of IPv6 - Display the switch configuration - Set the switch operating speed - Set the web enabled state - Set the zone FlexPars state - Set the Zoning RSCN state for the switch Step 3 Set the switch offline. The switch must be offline before changing the mode to interop. Config.Switch> interopmode open Error 045: Not Allowed While Switch Online Note To change to interop mode, the switch must be set to offline. Config.Switch> root Root> maint system Maint.System> setonlinestate 0 Maint.System> root Root> show switch State: Offline <==== switch is now offline R_A_TOV: 100 E_D_TOV: 20 Preferred Domain ID: 2 Domain ID Offset: 96 Switch Priority: Never Principal Speed: 2 Gb/sec Rerouting Delay: Interop Mode: McDATA Fabric 1.0 Active Domain ID: 2 World Wide Name: 10:00:08:00:88:A0:7A:74 Insistent Domain ID: Domain RSCN: Zoning RSCN: FC Address Domain: 62 (hex) Limited Fabric RSCN: Zone FlexPars: Fabric Filtering RSCN Zone Isolation: Fabric Filtering Safe Zoning: ISL FSPF Cost: By Port Speed Web : Frame Resize State: Block Dup WWN State: API : API Management IP: Password Exp. Time: 0 Step 4 Set the mode to interop. Root> config switch Config.Switch> interopmode open Warning: Zone members configured by domain and port will be ignored. Config.Switch> root Root> show switch State: Offline <==== still offline R_A_TOV: 100 E_D_TOV: 20 Preferred Domain ID: 2 Domain ID Offset:

6 Configuration Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Switch Priority: Never Principal Speed: 2 Gb/sec Rerouting Delay: Interop Mode: Open Fabric 1.0 <=== now in interop mode Active Domain ID: 2 World Wide Name: 10:00:08:00:88:A0:7A:74 Insistent Domain ID: Domain RSCN: Zoning RSCN: FC Address Domain: 62 (hex) Limited Fabric RSCN: Zone FlexPars: Fabric Filtering RSCN Zone Isolation: Fabric Filtering Safe Zoning: ISL FSPF Cost: By Port Speed Web : Frame Resize State: Block Dup WWN State: API : API Management IP: Password Exp. Time: 0 Step 5 Set the preferred domain ID, with an offset of 0x60. In this example, the McData switch is domain ID 0x61 (decimal 97). The FC IDs for nodes on this switch are 61xxxx. Root> config switch Config.Switch> prefdo Config.Switch> prefdomainid 1 Config.Switch> root Root> maint system Maint.System> setonlinestate 1 Maint.System> root Root> show switch State: Online <==== now online R_A_TOV: 100 E_D_TOV: 20 Preferred Domain ID: 1 <==== Domain ID 97 Domain ID Offset: 96 Switch Priority: Never Principal Speed: 2 Gb/sec Rerouting Delay: Interop Mode: Open Fabric 1.0 <==== in interop mode Active Domain ID: 1 World Wide Name: 10:00:08:00:88:A0:7A:74 Insistent Domain ID: Domain RSCN: Zoning RSCN: FC Address Domain: 61 (hex) Limited Fabric RSCN: Zone FlexPars: Fabric Filtering RSCN Zone Isolation: Fabric Filtering Safe Zoning: ISL FSPF Cost: By Port Speed Web : Frame Resize State: Block Dup WWN State: API : API Management IP: Password Exp. Time: 0 5-6

7 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Verification Configuring the MDS 9000 Switch See Chapter 3, MDS 9000 Core with Brocade Edge Topology (Interop Mode 1), for examples of how to set the MDS 9000 switch to interop mode. Verification This section highlights the commands used to verify that the fabric is up and running in interoperability mode. It includes the following topics: Verifying the McData 6064 Switch, page 5-7 Verifying the MDS 9513 Switch, page 5-9 Verifying the McData 6064 Switch The following examples show the commands used to verify the configuration of the McData 6064 switch: Root> show switch State: Online R_A_TOV: 100 E_D_TOV: 20 Preferred Domain ID: 1 Domain ID Offset: 96 Switch Priority: Never Principal Speed: 2 Gb/sec Rerouting Delay: Interop Mode: Open Fabric 1.0 Active Domain ID: 1 World Wide Name: 10:00:08:00:88:A0:7A:74 Insistent Domain ID: Domain RSCN: Zoning RSCN: FC Address Domain: 61 (hex) Limited Fabric RSCN: Zone FlexPars: Fabric Filtering RSCN Zone Isolation: Fabric Filtering Safe Zoning: ISL FSPF Cost: By Port Speed Web : Frame Resize State: Block Dup WWN State: API : API Management IP: Password Exp. Time: 0 Root> show system Name: M6064 Description: McData-6064 Contact: Field Support Location: LabD-Interop Date/Time: 08/23/ :53:21 Serial Number: Type Number: Model Name: ED-64M Model Number:

8 Verification Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) EC Level: Firmware Version: Beaconing: Issue the show port status command to verify that the correct ports are online and are type E port or F port. Root> show port status Port State Type Attached WWN Beaconing Reason No Light gport None 1 No Light gport None 2 No Light gport None 3 No Light gport None 4 Online eport 20:01:00:05:9B:01:B4:B3 5 No Light gport None 6 No Light gport None 7 No Light gport None 8 No Light gport None 24 No Light gport None 25 No Light gport None 26 No Light gport None 27 Online fport 10:00:00:00:C9:D0:92:E6 28 No Light gport None 29 No Light gport None 30 No Light gport None 31 No Light gport None 32 Online eport 20:01:00:05:9B:01:B4:B3 33 No Light gport None 60 No Light gport None 61 No Light gport None 62 No Light gport None 63 No Light gport None The show nameserver command shows that the Netfinity host has logged into the McData switch: Root> show nameserver DID Type PortId Port Name Node Name COS FC N 611F13 10:00:00:00:C9:D0:92:E6 20:00:00:00:C9:D0:92:E6 2-3 Unknown FC4 types decode information can be viewed through the Show nameserverfc4types CLI command: Root> show nameserverfc4types 0. ISO/IEC LLC 1. ISO/IEC LLC/SNAP 2. SCSI-FCP 3. SCSI-GPP 4. IPI-3 Master 5. IPI-3 Slave 6. IPI-3 Peer 7. CP IPI-3 Master 8. CP IPI-3 Slave 9. CP IPI-3 Peer 10. SBCCS-Channel 11. SBCCS-Cntrl Unit 12. FC Srvcs 13. FC-FG 14. FC-XS 15. FC-AL 16. SNMP 17. HIPPI-FP 18. Vendor Unique 5-8

9 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Verification Root> show loginserver Port BB Crdt RxFldSz COS Port Name Node Name :00:00:00:C9:D0:92:E6 20:00:00:00:C9:D0:92:E6 To view the FSPF routes used by the McData 3032 switch, use the Web GUI tool (Figure 5-2). There is no command line entry available to show this information. Figure 5-2 McData Core Displaying Routes Verifying the MDS 9513 Switch The following examples show the commands used to verify the configuration of the MDS 9513 switch: MDS9513(config)# show version Cisco Nexus Operating System (NX-OS) Software TAC support: Documents: Copyright (c) , Cisco Systems, Inc. All rights reserved. The copyrights to certain works contained herein are owned by other third parties and are used and distributed under license. Some parts of this software are covered under the GNU Public License. A copy of the license is available at Software BIOS: version loader: version N/A kickstart: version 5.2(1) system: version 5.2(1) BIOS compile time: 01/08/09 kickstart image file is: bootflash:///m9500-sf2ek9-kickstart-mz bin.s74 kickstart compile time: 12/25/ :00:00 [07/16/ :48:52] system image file is: bootflash:///m9500-sf2ek9-mz bin.s74 system compile time: 6/7/ :00:00 [07/17/ :15:24] Hardware cisco MDS 9513 (13 Slot) Chassis ("Supervisor/Fabric-2a") Motorola, 7447A, altivec with kb of memory. Processor Board ID JAE141501UD Device name: MDS9513 bootflash: kb 5-9

10 Verification Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) slot0: 0 kb (expansion flash) Kernel uptime is 20 day(s), 2 hour(s), 51 minute(s), 44 second(s) Last reset Reason: Unknown System version: 5.2(1) Service: plugin Core Plugin MDS9513(config)# show interface brief Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps) fc1/1 1 auto on down swl fc1/2 1 FX on down swl fc1/3 1 FX on down swl fc1/28 1 FX on sfpabsent fc1/29 1 FX on sfpabsent fc1/30 1 FX on sfpabsent fc1/31 1 FX on up swl FL 2 -- fc1/32 1 FX on sfpabsent fc1/33 1 FX on sfpabsent fc1/34 1 FX on sfpabsent fc1/35 1 FX on sfpabsent fc1/36 1 FX on sfpabsent fc1/37 1 auto on up swl E 2 -- fc1/38 1 FX on sfpabsent fc1/39 1 FX on sfpabsent fc1/40 1 FX on sfpabsent fc13/1 1 auto on up swl E 1 -- fc13/2 1 FX on sfpabsent fc13/3 1 FX on sfpabsent fc13/4 1 FX on sfpabsent MDS9513(config)# show vsan 1 vsan 1 information name:vsan0001 state:active interoperability mode:1 loadbalancing:src-id/dst-id/oxid operational state:up MDS9513(config)# show fcdomain vsan 1 The local switch is the Principal Switch. Local switch run time information: State: Stable Local switch WWN: 20:01:00:05:9b:01:b4:b3 Running fabric name: 20:01:00:05:9b:01:b4:b3 Running priority: 2 Current domain ID: 0x64(100) Local switch configuration information: State: FCID persistence: Auto-reconfiguration: Contiguous-allocation: 5-10

11 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Verification Configured fabric name: 20:01:00:05:30:00:28:df Optimize Mode: Configured priority: 128 Configured domain ID: 0x64(100) (preferred) Principal switch run time information: Running priority: 2 Interface Role RCF-reject fc1/37 Downstream fc13/1 Non-principal MDS9513(config)# show fcdomain domain-list vsan 1 Number of domains: 2 Domain ID WWN x64(100) 20:01:00:05:9b:01:b4:b3 [Local] [Principal] 0x61(97) MDS9513(config-if)# sh fspf internal route vsan 1 FSPF Unicast Routes VSAN Number Dest Domain Route Cost Next hops x61(97) 500 fc1/37 fc13/1 MDS9513(config)# show fcns database vsan 1 VSAN 1: FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE x611f13 N 10:00:00:00:c9:d0:92:e6 (Emulex) scsi-fcp:init 0x6401d4 NL 50:00:00:e0:10:32:d1:61 (Fujitsu) scsi-fcp:target 0x6401d5 NL 50:00:00:e0:10:32:d0:f1 (Fujitsu) scsi-fcp:target 0x6401d6 NL 50:00:00:e0:10:32:da:a1 (Fujitsu) scsi-fcp:target 0x6401d9 NL 50:00:00:e0:10:33:04:01 (Fujitsu) scsi-fcp:target 0x6401da NL 50:00:00:e0:10:33:fc:d1 (Fujitsu) scsi-fcp:target 0x6401dc NL 50:00:00:e0:10:5c:3c:21 (Fujitsu) scsi-fcp:target 0x6401e0 NL 50:00:00:e0:10:4b:b3:61 (Fujitsu) scsi-fcp:target 0x6401e1 NL 50:00:00:e0:10:33:06:51 (Fujitsu) scsi-fcp:target 0x6401e2 NL 50:00:00:e0:10:34:a4:c1 (Fujitsu) scsi-fcp:target 0x6401e4 NL 50:00:00:e0:10:32:d3:61 (Fujitsu) scsi-fcp:target 0x6401e8 NL 50:00:00:e0:10:33:01:d1 (Fujitsu) scsi-fcp:target 0x6401ef NL 50:00:00:e0:10:32:d8:81 (Fujitsu) scsi-fcp:target Total number of entries =

12 Verification Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) switch# show fcns database vsan 99 VSAN 99: FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE x N 21:00:00:e0:8b:07:a4:36 (QLogic) 0x7800d5 NL 22:00:00:20:37:0e:65:da (Seagate) scsi-fcp:target 0x7800d6 NL 22:00:00:20:37:14:74:e8 (Seagate) scsi-fcp:target 0x7800d9 NL 22:00:00:20:37:04:f8:a1 (Seagate) scsi-fcp:target 0x7800da NL 22:00:00:20:37:0c:6f:a9 (Seagate) scsi-fcp:target 0x7800dc NL 22:00:00:20:37:0d:b6:4b (Seagate) scsi-fcp:target 0x7800e0 NL 22:00:00:20:37:0e:65:44 (Seagate) scsi-fcp:target 0x7800e1 NL 22:00:00:20:37:0c:75:d5 (Seagate) scsi-fcp:target 0x7800e2 NL 22:00:00:20:37:04:ea:2b (Seagate) scsi-fcp:target 0x7800e4 NL 22:00:00:20:37:14:74:49 (Seagate) scsi-fcp:target 0x7800e8 NL 22:00:00:20:37:14:74:fc (Seagate) scsi-fcp:target Total number of entries = 11 You can use Cisco DCNM-SAN and Device Manager to verify the current state of the fabric. Figure 5-3 shows the fabric topology from Cisco DCNM-SAN. Figure 5-3 MDS 9000 Switch and McData Dual Core Displayed in Cisco DCNM-SAN Figure 5-4 shows Device Manager on the MDS 9513 switch in the example topology. It shows which ports are active as E ports. 5-12

13 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Verification Figure 5-4 MDS 9513 Switch Device Manager Showing Active Ports Figure 5-5 shows the status of the E ports that verifies the link speed. Figure 5-5 Cisco DCNM-SAN Verifying Port Status and Type 5-13

14 Verification Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Figure 5-6 shows the domain ID of the switches in the fabric. Figure 5-6 Cisco DCNM-SAN Verifying Domains Figure 5-7 shows that VSAN 1 is operating in interop mode. Figure 5-7 Verifying Interop Mode is Set Figure 5-8 shows the MDS 9513 switch name server. This shows the edge devices that have registered. 5-14

15 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Zoning Figure 5-8 MDS 9513 Switch Name Server Entries Figure 5-9 shows the FSPF routes as calculated by this switch. Figure 5-9 FSPF Calculations in Cisco DCNM-SAN Zoning In this example topology, Cisco DCNM-SAN was used to create zones and zone sets. Cisco DCNM-SAN displays are also used to verify the zone and zone set information. Figure 5-10 shows the zones and zone sets displayed in Cisco DCNM-SAN. 5-15

16 Zoning Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Figure 5-10 Zoning Configuration for MDS 9000 Switch and McData Dual Core Topology Figure 5-11 shows the zone VZ1. Figure 5-11 Zone VZ1 Displayed in Cisco DCNM-SAN Figure 5-12 shows the FSPF traffic flow in this multivendor fabric. 5-16

17 Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) Zoning Figure 5-12 MDS 9000 Switch and McData Dual Core FSPF Data Flow Target JBOD VZ1 Host /31 1/37 13/ Cisco MDS 9513 McData Gigabit ISLs 5-17

18 Zoning Chapter 5 MDS 9000 Switch and McData Dual Core Topology (Interop Mode 1) 5-18

MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1)

MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) 4 CHAPTER MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) This chapter describes how to set up a basic core-edge topology with an MDS 9000 switch configured for interop mode 1 at the

More information

MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1)

MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) CHAPTER 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) This chapter describes how to set up a basic core-edge topology with an MDS 9000 switch configured for interop mode 1 at the

More information

MDS 9000 Core with Brocade 3900/12000 Edge Topology

MDS 9000 Core with Brocade 3900/12000 Edge Topology CHAPTER 6 MDS 9000 Core with Brocade 3900/12000 Edge Topology This chapter describes how to set up a basic core-edge topology with one MDS 9000 switch configured for interop mode 1 at the core and two

More information

MDS 9020 Switch Interoperability

MDS 9020 Switch Interoperability CHAPTER 10 This chapter describes how to connect the Cisco MDS 9020 fabric switch to a third-party switch, and it includes the following sections: Specifications, page 10-5 Expected Topology Behavior,

More information

Advanced Fibre Channel Features

Advanced Fibre Channel Features This chapter describes how to configure advanced Fibre Channel features. This chapter includes the following sections: and Concepts, page 1 and Concepts Fibre Channel Timeout Values You can modify Fibre

More information

Interoperability Guidelines for Non-Cisco Switches

Interoperability Guidelines for Non-Cisco Switches APPENDIXA Interoperability Guidelines for Non-Cisco Switches This appendix includes information on changing interop modes and describes release-specific behavior for certain versions of Brocade, McData,

More information

hp Storageworks Fabric Interoperability: Merging Fabrics Based on C-Series and B-Series Fibre Channel Switches

hp Storageworks Fabric Interoperability: Merging Fabrics Based on C-Series and B-Series Fibre Channel Switches Application Notes hp Storageworks Fabric Interoperability: Merging Fabrics Based on C-Series and B-Series Fibre Channel Switches Fifth Edition (April 2006) Part Number: AA-RV1ZE-TE This document summarizes.

More information

Interoperability Limitations

Interoperability Limitations CHAPTER 2 This chapter describes the restrictions and limitations imposed on specific vendor switches when working in interoperability mode. It includes the following sections: Cisco MDS 9000 Family, page

More information

MDS to MDS Basic Configuration with FCIP

MDS to MDS Basic Configuration with FCIP MDS to MDS Basic Configuration with FCIP Document ID: 47100 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information Configure Network Diagram Configurations

More information

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC CCIE Data Center Storage Networking Fibre Channel Switching Configuration Nexus 5500UP FC Initialization Allocate interfaces as type FC slot 1 port 25 32 type fc FC must start at top of module and count

More information

Contents. FCoE commands 0

Contents. FCoE commands 0 Contents FCoE commands 0 FCoE mode commands 0 display fcoe-mode 0 fcoe-mode 0 VFC interface commands 2 bandwidth 2 bind interface 2 default 3 description 4 display interface vfc 5 fc mode 8 interface vfc

More information

F Commands CHAPTER. Send documentation comments to

F Commands CHAPTER. Send documentation comments to CHAPTER 7 The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. Please

More information

Fibre Channel Gateway Overview

Fibre Channel Gateway Overview CHAPTER 5 This chapter describes the Fibre Channel gateways and includes the following sections: About the Fibre Channel Gateway, page 5-1 Terms and Concepts, page 5-2 Cisco SFS 3500 Fibre Channel Gateway

More information

Configuring Fibre Channel Interfaces

Configuring Fibre Channel Interfaces This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is

More information

Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x

Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 2018 Cisco Systems, Inc. All rights

More information

Implementing Smart Zoning On IBM Cisco SANs

Implementing Smart Zoning On IBM Cisco SANs Implementing Smart Zoning On IBM Cisco SANs What Is Smart Zoning Zoning on any SAN is used to limit what SAN devices can see other devices. This makes SANS easier to administer and limits the impact on

More information

Managing FLOGI, Name Server, FDMI, and RSCN Databases, page 1

Managing FLOGI, Name Server, FDMI, and RSCN Databases, page 1 Managing FLOGI, Name Server, FDMI, and RSCN Databases This chapter describes how to configure and manage FLOGI, name server FDMI, and RSCN databases. This chapter includes the following sections:, page

More information

Inter-VSAN Routing Configuration

Inter-VSAN Routing Configuration CHAPTER 16 This chapter explains the inter-vsan routing (IVR) feature and provides details on sharing resources across VSANs using IVR management interfaces provided in the switch. This chapter includes

More information

Symbols. Numerics INDEX

Symbols. Numerics INDEX INDEX Symbols *(wildcard) port security authorization 18-5 Numerics 16-port modules BB_credits 10-12 LEDs 10-15 preserving configurations 7-7 See also switching modules 32-port modules BB_credits 10-12

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!  We offer free update service for one year PASS4TEST IT Certification Guaranteed, The Easy Way! \ http://www.pass4test.com We offer free update service for one year Exam : 642-359 Title : Implementing Cisco Storage Network Solutions Vendors : Cisco

More information

Configuring Fabric Configuration Server

Configuring Fabric Configuration Server CHAPTER 12 This chapter describes the Fabric Configuration Server (FCS) feature provided in the Cisco MDS 9000 Family of directors and switches. It includes the following sections: About FCS, page 12-1

More information

HP FlexFabric 5700 Switch Series

HP FlexFabric 5700 Switch Series HP FlexFabric 5700 Switch Series FCoE Command Reference Part number: 5998-6675 Software version: Release 2416 Document version: 6W100-20150130 Legal and notice information Copyright 2015 Hewlett-Packard

More information

Configuring Microsoft Windows XP iscsi Host to MDS/IPS 8

Configuring Microsoft Windows XP iscsi Host to MDS/IPS 8 Configuring Microsoft Windows XP iscsi Host to MDS/IPS 8 Document ID: 45140 Contents Introduction Prerequisites Requirements Components Used Conventions Background Theory Configure Network Diagram Configurations

More information

F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example

F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example Document ID: 117781 Contributed by Edward Mazurek, Cisco TAC Engineer. Sep 05, 2014 Contents Introduction Prerequisites

More information

Configuring and Managing Zones

Configuring and Managing Zones Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 30 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric,

More information

Contents. FCoE commands 1

Contents. FCoE commands 1 Contents FCoE commands 1 FCoE mode commands 1 display fcoe-mode 1 fcoe-mode 1 VFC interface commands 3 bandwidth 3 bind interface 3 default 5 description 5 display interface vfc 6 fc mode 9 interface vfc

More information

Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces

Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces This chapter provides details about configuring native fiber channels on Cisco Nexus 2348UPQ FEX, and contains the following sections:

More information

Fibre Channel Specialist Lab

Fibre Channel Specialist Lab Fibre Channel Specialist Lab 203.05 QuickTools Management GUI Objective: This lab will familiarize the learner with the QuickTools Graphical User Interface for SANbox Fibre Channel switches and directors.

More information

Switch Interoperability Guide

Switch Interoperability Guide IBM FIbre Channel Switch Interoperability GUIDE v2 9 / 03 Fibre Channel IBM BladeCenter Switch Interoperability Guide v2 9/2003 S A N THE ONLY SOURCE FOR MULTI-VENDOR INTEROPERABILITY QLOGIC PRESS QLOGIC

More information

Configuring and Managing Zones

Configuring and Managing Zones CHAPTER 5 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric, you can create zones to increase network security and

More information

IVR Zones and Zonesets

IVR Zones and Zonesets Information about, page 1 Default Settings, page 3 Licensing Requirements, page 3 Guidelines and Limitations, page 3 Configuring, page 4 Verifying IVR Configuration, page 11 Feature History, page 12 Information

More information

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c)

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c) Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c) Release Date: April 5, 2011 Part Number: F0 This document describes the caveats and limitations for switches in the Cisco MDS 9000

More information

Troubleshooting Zones and Zone Sets

Troubleshooting Zones and Zone Sets CHAPTER 14 This chapter describes how to identify and resolve problems that might occur while implementing zones and zone sets on switches in the Cisco MDS 9000 Family. It includes the following sections:

More information

Configuring PortChannels

Configuring PortChannels This chapter provides information about PortChannels and how to configure the PortChannels. Finding Feature Information, page 1 Information About PortChannels, page 1 Prerequisites for PortChannels, page

More information

Configuring and Managing Zones

Configuring and Managing Zones CHAPTER 19 Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric, you can create zones to increase network security and

More information

This table describes the supervisor module options for switches in the Cisco MDS 9000 Family.

This table describes the supervisor module options for switches in the Cisco MDS 9000 Family. This chapter describes how to manage switching and services modules (also known as line cards) and provides information on monitoring module states. About Modules, page 1 Maintaining Supervisor Modules,

More information

Using the Cisco NX-OS Setup Utility

Using the Cisco NX-OS Setup Utility This chapter contains the following sections: Configuring the Switch, page 1 Configuring the Switch Image Files on the Switch The Cisco Nexus devices have the following images: BIOS and loader images combined

More information

Send documentation comments to

Send documentation comments to Send documentation comments to mdsfeedback-doc@cisco.com. INDEX Numerics 16-port modules BB_credits 18-8 32-port modules BB_credits 18-8 configuration guidelines 18-5 A AAA description 27-1 distributing

More information

Using the Cisco NX-OS Setup Utility

Using the Cisco NX-OS Setup Utility This chapter contains the following sections: Configuring the Switch, page 1 Configuring the Switch Image Files on the Switch The Cisco Nexus devices have the following images: BIOS and loader images combined

More information

Configuring a Dual Fabric SAN Environment

Configuring a Dual Fabric SAN Environment CHAPTER 10 Dual fabric SAN environments are an important configuration requirement. You can use CSM modules in combination with the Inter-VSAN Routing (IVR) feature to operate across two isolated fabrics.

More information

Tech Note on Priority Transmit B2B Credits in MDS Switches

Tech Note on Priority Transmit B2B Credits in MDS Switches Tech Note on Priority Transmit B2B Credits in MDS Switches Contents Introduction Prerequisites Requirements Components Used Understand Priority Transmit B2B Credits in MDS Switch For an Inter-Switch Link

More information

Verify that your username has network-admin privileges. Assign a new network administrator password if your username has network-admin privileges.

Verify that your username has network-admin privileges. Assign a new network administrator password if your username has network-admin privileges. Troubleshooting Troubleshooting, page 1 Troubleshooting Recovering a Lost Password This section describes how to recover a lost network administrator password using the console port of the switch. You

More information

Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide

Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: OL-xxxxx-xx THE

More information

Troubleshooting N-Port Virtualization

Troubleshooting N-Port Virtualization CHAPTER 9 This chapter describes how to identify and resolve problems that can occur with N-Port virtualization. It includes the following sections: Overview, page 9-1 Initial Troubleshooting Checklist,

More information

Fibre Channel Switch Interoperability Guide

Fibre Channel Switch Interoperability Guide SIMPLE LOW COST SANS v4 12 04 IBM BladeCenter Fibre Channel Switch Interoperability Guide QLOGIC PRESS IBM BladeCenter Fibre Channel Switch Interoperability Guide Version 4.0 Copyright IBM Corporation

More information

Cisco MDS NX-OS Release 6.2Configuration Limits 2

Cisco MDS NX-OS Release 6.2Configuration Limits 2 Cisco MDS NX-OS Release 6.2 Configuration Limits Cisco MDS NX-OS Release 6.2Configuration Limits 2 Switch Level Fibre Channel Configuration Limits for Cisco MDS 9000 Series Switches 2 Fabric Level Fibre

More information

UCS Engineering Details for the SAN Administrator

UCS Engineering Details for the SAN Administrator UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want

More information

Configuring the Fibre Channel Gateway

Configuring the Fibre Channel Gateway CHAPTER 6 This chapter describes Fibre Channel gateway configuration and includes the following sections: Before You Begin, page 6-1 Administering the Fibre Channel Gateway, page 6-1 Pre-configuration

More information

Deploying IP Storage Solutions with the Cisco MDS 9000

Deploying IP Storage Solutions with the Cisco MDS 9000 Deploying IP Storage Solutions with the Cisco MDS 9000 In this lab, you will implement IP storage services on the MDS 9000 platform, including both Fibre Channel over IP (FCIP) and Internet SCSI (iscsi)

More information

CCIE Data Center Storage Networking. Fibre Channel Switching

CCIE Data Center Storage Networking. Fibre Channel Switching CCIE Data Center Storage Networking Fibre Channel Switching What is Fibre Channel? From a high level, replaces SCSI disk cable with a network From this To this What is Fibre Channel? Protocol stack primarily

More information

Flash Devices in the Cisco MDS 9000 Supervisor Module. External CompactFlash in the Cisco MDS 9000 Supervisor Module.

Flash Devices in the Cisco MDS 9000 Supervisor Module. External CompactFlash in the Cisco MDS 9000 Supervisor Module. CHAPTER 4 This chapter lists the information you need to have before you begin using your MDS 9000 Switch. For information on setting up the switch and doing an initial configuration, refer to the Cisco

More information

Cisco Nexus 5600 Series NX-OS SAN Switching Configuration Guide, Release 7.x

Cisco Nexus 5600 Series NX-OS SAN Switching Configuration Guide, Release 7.x Cisco Nexus 5600 Series NX-OS SAN Switching Configuration Guide, Release 7.x Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000

More information

DCNX5K: Configuring Cisco Nexus 5000 Switches

DCNX5K: Configuring Cisco Nexus 5000 Switches Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco

More information

Managing FLOGI, Name Server, FDMI, and RSCN Databases

Managing FLOGI, Name Server, FDMI, and RSCN Databases CHAPTER 17 Managing FLOGI, Name Server, FDMI, and RSCN Databases This chapter describes the fabric login database, the name server features, and Registered State Change Notification (RSCN) information

More information

1. Slow port emulation with R_RDY delay of us (1.5 seconds) 2. Port-monitor - slow port emulation with R_RDY delay of us (1.

1. Slow port emulation with R_RDY delay of us (1.5 seconds) 2. Port-monitor - slow port emulation with R_RDY delay of us (1. Contents Introduction Topology Restrictions in Cisco NX-OS Software Releases Cisco NX-OS Software Release 5.2(8) Cisco NX-OS Software Releases Earlier than 5.2(6) Test 1: Slow Port Emulation with R_RDY

More information

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(1a)

Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(1a) Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(1a) Release Date: February 22, 2010 Part Number: I0 This document describes the caveats and limitations for switches in the Cisco MDS

More information

Troubleshooting Your Fabric

Troubleshooting Your Fabric CHAPTER 66 This chapter describes basic troubleshooting methods used to resolve issues with switches. This chapter contains the following sections: Troubleshooting Tools and Techniques, page 66-1 Analyzing

More information

Configuring SAN Port Channel

Configuring SAN Port Channel Configuring SAN Port Channel This chapter contains the following sections: Configuring SAN Port Channels, page 1 Configuring SAN Port Channels SAN port channels refer to the aggregation of multiple physical

More information

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites

More information

Cisco I/O Accelerator Deployment Guide

Cisco I/O Accelerator Deployment Guide Cisco I/O Accelerator Deployment Guide Introduction This document provides design and configuration guidance for deploying the Cisco MDS 9000 Family I/O Accelerator (IOA) feature, which significantly improves

More information

Cisco Nexus B22 Blade Fabric Extender for IBM

Cisco Nexus B22 Blade Fabric Extender for IBM Cisco Nexus B22 Blade Fabric Extender for IBM Design and Deployment Guide 2014 Cisco IBM. All rights reserved. Page 1 Contents Introduction... 3 Network Diagram... 3 Hardware Installation... 5 Fabric Extender

More information

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter Product Guide The Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter provide highperformance

More information

Getting Started. Enabling SSH

Getting Started. Enabling SSH This chapter provides an overview of the basic configurations that need to be completed before getting started with IOA-specific configurations: Enabling SSH, page 1 Enabling CFS, page 2 IP Access Lists,

More information

Configuring Interface Buffers

Configuring Interface Buffers This chapter provides information about interfaces buffers, its features, and how to configure the interface buffers Finding Feature Information, page 1 Information About Interface Buffers, page 1, page

More information

Cisco MDS 9000 Series NX-OS Interfaces Configuration Guide

Cisco MDS 9000 Series NX-OS Interfaces Configuration Guide Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 2017 Cisco Systems, Inc. All rights

More information

P Commands. Send documentation comments to CHAPTER

P Commands. Send documentation comments to CHAPTER CHAPTER 17 The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. See

More information

Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x

Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x First Published: 2018-07-11 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors White Paper Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors What You Will Learn As SANs continue to grow in size, many factors need to be considered to help scale

More information

Cisco UCS Local Zoning

Cisco UCS Local Zoning Configuration Guide Cisco UCS Local Zoning Configuration Guide May 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 30 Contents Overview...

More information

Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2)

Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(2) Release Date: November 11, 2008 Part Number: O0 This document describes the caveats and limitations for switches in the Cisco MDS

More information

Building and Scaling BROCADE SAN Fabrics: Design and Best Practices Guide

Building and Scaling BROCADE SAN Fabrics: Design and Best Practices Guide Building and Scaling BROCADE SAN Fabrics: Design and Best Practices Guide 53-0001575-01 BROCADE Technical Note Page: 1 of 31 BROCADE SAN Integration and Application Department Last Updated March 29, 2001

More information

Chassis Tasks. Viewing Cards on a Chassis. Viewing Card Summary Information CHAPTER

Chassis Tasks. Viewing Cards on a Chassis. Viewing Card Summary Information CHAPTER CHAPTER 3 These topics describe the Chassis display tasks: Viewing Cards on a Chassis, page 3-1 Viewing Internal Gateway Ports, page 3-8 Viewing Physical Ports on a Chassis, page 3-9 Viewing Power Supply

More information

HP 6125XLG Blade Switch

HP 6125XLG Blade Switch HP 6125XLG Blade Switch FCoE Configuration Guide Part number: 5998-3726 Software version: Release 2306 Document version: 6W100-20130912 Legal and notice information Copyright 2013 Hewlett-Packard Development

More information

AVANTUS TRAINING PTE LTD

AVANTUS TRAINING PTE LTD Implementing Cisco Data Center Unified Fabric (DCUFI) 5 Days Instructor-Led Course Overview The Implementing Cisco Data Center Unified Fabric (DCUFI) v5.0 is a five-day instructor-led training course designed

More information

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary

More information

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections: This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page

More information

Cisco Exam Questions & Answers

Cisco Exam Questions & Answers Cisco 642-997 Exam Questions & Answers Number: 642-997 Passing Score: 900 Time Limit: 120 min File Version: 36.4 http://www.gratisexam.com/ Cisco 642-997 Exam Questions & Answers Exam Name: Implementing

More information

Configuring VSANs and Interfaces

Configuring VSANs and Interfaces CHAPTER 3 You can achieve higher security and greater stability in Fibre Channel fabrics by using virtual storage area networks (VSANs). VSANs provide isolation among devices that are physically connected

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

Troubleshooting. General System Checks. Troubleshooting Components. Send documentation comments to

Troubleshooting. General System Checks. Troubleshooting Components. Send documentation comments to APPENDIX B This appendix describes how to troubleshoot the Cisco MDS 9020 Fabric hardware installation, and it includes the following information: General System Checks, page B-1 Components, page B-1 Identifying

More information

Fabric Manager Client

Fabric Manager Client CHAPTER 5 Cisco is a java-based GUI application that provides access to the Fabric Manager applications from a remote workstation. This chapter contains the following sections: About, page 5-1 Launching

More information

Fibre Channel Storage Area Network Design BRKSAN-2701

Fibre Channel Storage Area Network Design BRKSAN-2701 Fibre Channel Storage Area Network Design BRKSAN-2701 Agenda Brief SAN Technology Overview Fibre Channel Protocol Virtual SAN (VSAN), Zoning Port Channels NPV and FlexAttach F-Port Port Channel and F-Port

More information

Cisco MDS 9000 Family NX-OS Licensing Guide, Release 6.x

Cisco MDS 9000 Family NX-OS Licensing Guide, Release 6.x Cisco MDS 9000 Family NX-OS Licensing Guide, Release 6.x Revised: July 10, 2017, OL-29297-02 Licensing Cisco MDS 9000 Series NX-OS Software Features Licenses are available for all switches in the Cisco

More information

45 10.C. 1 The switch should have The switch should have G SFP+ Ports from Day1, populated with all

45 10.C. 1 The switch should have The switch should have G SFP+ Ports from Day1, populated with all Addendum / Corrigendum Dated 29/09/2017 Tender Ref No. - 236/387/DCCS/2010/IREDA/1 Dated: 22/09/2017 Name of Project - Supply Installation and Support Services of Data centers S. No. Document Reference

More information

Configuring System Message Logging

Configuring System Message Logging CHAPTER 3 This chapter describes how to configure system message logging on Cisco DCNM-SAN. It includes the following sections: Information About System Message Logging, page 3-1 Guidelines and Limitations,

More information

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide Cisco MDS NX-OS Release 6.2(1) April 2013 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

Upgrading or Downgrading the Cisco Nexus 3500 Series NX-OS Software

Upgrading or Downgrading the Cisco Nexus 3500 Series NX-OS Software Upgrading or Downgrading the Cisco Nexus 3500 Series NX-OS Software This chapter describes how to upgrade or downgrade the Cisco NX-OS software. It contains the following sections: About the Software Image,

More information

Fibre Channel Specialist Lab

Fibre Channel Specialist Lab Fibre Channel Specialist Lab 203.11 Enterprise Fabric Suite Operation Objective: This lab will familiarize the learner with the Enterprise Fabric Suite Graphical User Interface for SANbox switches. Lab

More information

McDATA Sphereon 4500 Fabric Switch Product Manager User Manual

McDATA Sphereon 4500 Fabric Switch Product Manager User Manual 0F'$7$&RUSRUDWLRQ McDATA Sphereon 4500 Fabric Switch Product Manager User Manual P/N 620-000158-200 REV A 380 Interlocken Crescent Broomfield, CO 80021-3464 Corporate Headquarters: 800-545-5773 Sales E-mail:

More information

P Commands. Cisco MDS 9000 Series Command Reference 1

P Commands. Cisco MDS 9000 Series Command Reference 1 P s passive-mode, page 3 password strength-check, page 4 pathtrace, page 6 peer (DMM job configuration submode), page 11 peer-info ipaddr, page 12 periodic-inventory notification, page 14 permit (IPv6-ACL

More information

HP StorageWorks Director and Edge Switch Release Notes ( )

HP StorageWorks Director and Edge Switch Release Notes ( ) HP StorageWorks Director and Edge Switch Release Notes (09.09.09) Part Number: 5697-0776 Twelth edition: November 2010 Legal and notice information Copyright 2007, 2010 Hewlett-Packard Development Company,

More information

IBM To Resell Cisco Systems MDS 9000 Multilayer Switch and Director Family of Intelligent Storage Networking Products

IBM To Resell Cisco Systems MDS 9000 Multilayer Switch and Director Family of Intelligent Storage Networking Products Hardware Announcement February 17, 2003 IBM To Resell Cisco Systems MDS 9000 Multilayer Switch and Director Family of Intelligent Storage Networking Products Overview IBM announces the availability of

More information

FCoE Cookbook for HP Virtual Connect

FCoE Cookbook for HP Virtual Connect Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs

More information

Cisco MDS 9000 Family Blade Switch Solutions Guide

Cisco MDS 9000 Family Blade Switch Solutions Guide . Solutions Guide Cisco MDS 9000 Family Blade Switch Solutions Guide Introduction This document provides design and configuration guidance for administrators implementing large-scale blade server deployments

More information

Troubleshooting Cisco Storage Networks

Troubleshooting Cisco Storage Networks 1 Troubleshooting Cisco Storage Networks Session 2 Session Agenda Fibre Channel Ports Physical Level and Type Focus on Device Discovery and Fibre Channel Services E-Port ISL Troubleshooting, Including

More information

HP StorageWorks Fabric OS 6.1.2_cee1 release notes

HP StorageWorks Fabric OS 6.1.2_cee1 release notes HP StorageWorks Fabric OS 6.1.2_cee1 release notes Part number: 5697-0045 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Copyright 2009 Brocade

More information

Simplify. QLogic Fibre Channel Switch. Event Message Guide. Firmware Version 6.5, A Page i

Simplify. QLogic Fibre Channel Switch. Event Message Guide. Firmware Version 6.5, A Page i R Simplify QLogic Fibre Channel Switch Event Message Guide Firmware Version 6.5, 6.6 59060-03 A Page i QLogic Fibre Channel Switch Event Message Guide S Information furnished in this manual is believed

More information

EFCM Basic User Manual P/N REV A

EFCM Basic User Manual P/N REV A EFCM Basic User Manual P/N 620-000240-000 REV A Record of Revisions and Updates Revision Date 620-000245-000 7/2005 Initial release of the manual Copyright 2002-2005 McDATA Corporation. All rights reserved.

More information

I Commands. I Commands 1

I Commands. I Commands 1 identity, on page 4 ingress-sa, on page 6 initiator, on page 7 in-order-guarantee, on page 8 install all, on page 9 install clock-module, on page 15 install license, on page 17 install module bios, on

More information

Cisco MDS Port 10-Gbps Fibre Channel over Ethernet Module

Cisco MDS Port 10-Gbps Fibre Channel over Ethernet Module Data Sheet Cisco MDS 9700 48-Port 10-Gbps Fibre Channel over Ethernet Module Product Overview Multiprotocol storage networking is central to Cisco Unified Fabric, providing a networking platform for IT

More information