1 1 Introduction to the software 1/2 1 Introduction to the software The monitoring software is matched with our company controller. It can monitor different controller models for local monitor and remote monitor. Main functions include: displaying real-time data for wind power, solar panel power, battery; storage and transferring system operation data; modify and set the controller parameters; control wind turbine operating status. Monitoring data displays through curvilinear figure, real-time data tables, stimulated diagrams and other forms. Users can be warned by alarm mode, the alarm content is saved automatically for reference. This software is simple to use with large capacity, full functions, multi-language version, etc. The following are brief introduction to every function model. Multi-type interface unit: The software supports a variety of forms such as serial com port, GPRS, internet etc. Controller can directly be connected with serial port in the local; when the controller is distributed in different locations, especially in the wild, you can connect it through the GPRS or wired Internet. Access types can be mixed in use. And a typical multi-use-pattern is showing below: Database Storage Unit: This software can choose the MYSQL database system or ACCESS database system according to node number. ACCESS database system is recommended for a dozen or dozens of node numbers. It is convenient and quick and you do not need to install separately but with limited storage capability. So for hundred of node number, user is recommended to choose MYSQL database system (If choose the MYSQL database, user need to install the MYSQL database software at the end of the software installation.) Multi-type Display Unit: Software display type includes the trends chart, mimic diagram, data table, multi-channel display. Trends chart shows node data trends of the controller in a period time. The graph can show the data for wind, solar and battery. Mimic diagram directly show the wind turbine, wind power, solar power data and running state. Date table shows real-time data intensively through the database forms, data refresh auto by time. Multi-channel display divides by region, the running state of the controller in the region shall be displayed in which you choose.

2 1 Introduction to the software 2/2 Parameter configuration unit No matter the access form is a serial port GPRS or wired network, the software can configure and control the controller running state. After connected with PC, the system can identify different types of controller auto, user can check and adjust the parameters, change wind turbine running state or reset factory default through the software.

3 2 Software Installation 1/5 2 Software Installation 2.1 System Requirement Item Recommendations CPU Dual-core 1GHz or above Memory 1G or above Hard Disk 4G or above Operation System Windows XP, Vista, Windows 7,windows 8 Resolution Installation Procedure 1. In system Windows 7, Vista, Windows 8, right click on the installer WPNet Setup.exe, start the software via run as administrator, the program installation is starting. (Remark: In system Windows 2000, Windows XP just double-click on the WPNet Setup.exe to install the program.) Click [Next] to continue. 2. Select database and click [Next] to continue. If MYSQL is selected then you need to install MYSQL database.

4 2 Software Installation 2/5 3. Input the User information and click [Next]. 4. Select installation path in your disk. Click [Next].

5 2 Software Installation 3/5 5. Create shortcuts and click [Next]. 6. Click [Finish] to exit.

6 2 Software Installation 4/5 Note: If you select MYSQL database during the installation process, then firstly you should save mysql win32.msi (MYSQL database installation files) and mysql-connector-odbc win32.msi (MYSQL database ODBC driver) in the same directory with the monitoring software, then install monitoring software first. You need to install mysql win32.msi and mysql-connector-odbc win32.msi again at the end of software installation. You need to configure the MYSQL database in the installation process of mysql win32.msi. In the following interface, the New root password edit box should be filled with power121, other configurations are just set as default.

7 2 Software Installation 5/5 2.3 Uninstall software Click Start->Program->WinPower Net->unload WinPower Net to uninstall this software.

8 Wind & Solar Hybrid Controller Monitoring Software 1/1 Wind & Solar Hybrid Controller Monitoring Software User Manual Version: 3.0

9 3 1/1 3.1 Starting the software The software can be started by: Selecting Start->Programs->WinPowerNet Double-clicking the WinPowerNet desktop shortcut Notes: In system Vista, Windows 7 or Windows 8, have to right-click the WinPowerNet desktop shortcut and select the run as administrator item to start the software. After the software start, the main interface appears, as shown below. mk:@msitstore:d:\winpower%20net\helpeng.chm::/starting%20the%20software...

10 3 1/1 3.2 Menu Bar System Switch User The submenu can be used to switch the current user logining the software. The default current user is anyone when the software starts. You can change the current user to be admin. The default password of user admin to login the software is admin. Only the user admin has the access to setting the controller parameters and wind turbine running state. Exit The submenu can be used to exit from the software

11 3 1/ View The software has four kind of interface to display data including trend diagram, data table, simulation graph and multi-path graph. The menu can be used to switch the interface among them. Trend Diagram After software starts, the default screen shows trend diagram as above. The meaning of each function area in the trend diagram is as following. A: Area & nodes displaying list, click the node in the list then the data of selected node will be displayed in the trend. B: Trend diagram options, click the check-box to choose or cancel the option, the trend of checked options will be displayed at the same time. C: Voltage-time trend, displaying voltage curve of checked option, the time length is 10 minutes. D: Power-time trend, displaying power curve of checked option, the time length is 10 minutes. E: Voltage-time and power-time radar graph, displaying voltage and power curve of checked option in a radar graph. The length of time is 24 hours, if the time lasts longer than 24 hours, the data will be displayed in cycle automatically. The red line points to the current time. F: Real-time data showing area, showing the real-data of selected node, including voltage, current, instantaneous power, daily total power, monthly total power and yearly total power of batteries, the wind generator and solar panels, etc. G: State signal indication, the details is shown in the table as below. Communication State Battery State Red Green Yellow Gray Over-Voltage Lower-Voltage Normal Normal No signal No signal Wind State Brake Normal Unloading or No signal Overload or Load1 is on and No signal

12 3 2/3 Output1 State Short circuit Current is normal but zero Output2 State Overload or Short circuit Load2 is on and Current is normal but zero Load1 is on but current is zero No signal Load2 is on but Current is zero Load1 is off Load2 is off H:Instant Message Bar: when system is abnormal (such as short circuit, over-voltage, over-speed brake, low voltage etc.), the alarm sounds, and instant message bar will display the corresponding error at the same time. Alarm sounds will be released when users click alarm confirmation. Data Table The data table displays real-time data of selected node within 20 seconds, including voltage, current, power of battery, wind turbine, solar panels; load current and fan speed. Simulation Graph

13 3 3/3 Simulation graph shows systematic relationship chart and the real time data of battery, wind turbine, solar in current system. Multi-path Graph Multi-path graph is used to show load state of all controllers in the same area, and gives convenience for user to monitor the running status of loads. The upper indicator of each icon shows the load state of controller and the lower indicator shows the load2 state of controller.

14 3 1/ Tools The software stores large amount of historical data records in computer when runs. The records include historical data of system running, log information, alarm information and system power records. Tools menu is used to check these records. The function of it s submenus is described as below. Query History Data Click Tools->Query History Data, the query data interface will show as above. After choosing Area Name and Ctrl Name, setting Begin Time and End Time, click Requery button, the historical data of the controller between begin time and end time will be listed in the data grid. Click Save To Excel button, the software will export the historical data into an excel file. Click Curve button, the graphic interface displays as the following figure shows. Click check-box selecting the parameters to display in the graphic interface. Different parameter curve shows with different color. Click Adjust View Range button to adjust the display range of parameters.

15 3 2/4 Query Log Click Tools->Query Log, the log query widow shows as above. Select time period and event type, click Query button then log information will be listed in the grid.

16 3 3/4 Query Power Click Tools->Query Power, the power query widow shows as above. Select the controller by region and controller name, and choose query format as by day or month or year, then click "Requires" button user can view the electricity quantity records. Data shows in list and with histogram style. Clicking on the "Next>>" or "<<Prev" button can change query date. Click the Save To Excel button, the records in the list will be saved to an excel file. Query Alarm

17 3 4/4 Click Tools -> Query Alarm, the alarm query window shows as above. Select the controller by area name and controller name, input time period and select alarm type, then click Query button, the related alarm information will be listed in the grid. Note: When the communication between the software and the controller has been built, the software will sample the data from the controller automatically. If Access database is selected when install the software, all the data will be exported to excel files every day after 0 o clock and the database will be cleared up. Excel files are saved to subfolder HisData where the software is installed.

18 3 1/ Setting The menu is used to set area and node information, adjust controller system parameters and control the state of wind generator. But only the user admin has the privilege to adjust system parameters and control the state of wind generator. The menu has four submenus including parameters setting, fan s state control, area & node setting and options. Parameters Setting If current user is anyone, you have to switch it to admin. Then click Setting -> Parameters Setting, a frame shows as below. Select area name and controller name, then click Connect button. The controller parameters setting interface displays as below. The interface may be some different according to different controllers. You can change the parameters in the interface, then click Save Para button to save the changes. Or click Restore Factory button to restore the factory parameters. Otherwise you can select another controller name and click Connect button to view or change it s parameters. The meaning of parameters is described as following. General: Release Voltage, when battery voltage is up to the voltage, the controller begins to unload. Release Current, when wind current is up to the current, the controller begins to unload. Device ID, is the number of controller.

19 3 2/6 Charge: it applys for the lower-voltage-charge controllers. The admittance and start charge should be set according to the characteristics of the wind turbine output so that the wind turbine could achieve the best effect to match the controller. Output: Less Voltage, when battery voltage is lower than the voltage, the load will be off. Over Voltage, when battery voltage is up to the voltage, the load will be off. LessVolRes voltage, if the battery voltage increases to the voltage from lower-voltage state first time, the load will be on again. Day point voltage, if the sun panels output voltage is upper than the voltage, the controller predicates that it s day time. Night Point voltage, if the sun panels output voltage is lower than the voltage, the controller predicates that it s night time. The day point voltage and night point voltage can be used to control the load state. Load: Load output mode setting, including light control on/off, light control on/time control off, always on/off, light control on/off/time control half power, light control on/time control half power/ time control off, always half power. Running State Control If current user is anyone, you have to switch it to admin. Then Click Setting -> Running State Control, the following interface will appear. Select area and controller name, then click Connect button, the current state of wind turbine will show in the interface. Select the state option which you want the wind turbine to be, and then click Save button to save the change. Area & Node Setting Click Setting -> Area & Node Setting, the area and node setting interface will appear as below.

20 3 3/6 A. Area Setting In the Area Setting tab, input the area name and area memo, click Add Area button to add an area, and the area information will shown in the list on the left hand side. By clicking Remove Area button you can remove the selected area in the list. B. Node Setting In the Node Setting tab, select an area from area list, input the controller name which will be shown as the node name, and then select an interface type from type list. There are five types to be selected, including Serial Server (WM) Serial Server Com 485 Bus and WM Server.

21 3 4/6 If the interface type is Serial Server (WM), Module ID and Password are required as following. If the interface type is Serial Server, Device IP is required as following.

22 3 5/6 If the interface type is COM, then the COM PORT is required as following. If the interface type is 485 Bus, then Com Port and Device ID is required as following:

23 3 6/6 If the interface type is WM Server, Module ID and Password are required as following. By clicking "Add Node" button, controller node can be added and shown in the list below. Clicking Remove Node button can remove the selected node in the list. Note: After modifying the area and node setting, you have to click Save button to make the modification come into effect. Then restart the software.

24 4 System Integration and Configuration 1/10 4 System Integration and Configuration The software supports a variety of interfaces and can construct the local serial ports, remote network, remote wireless, mix varieties of forms above as monitoring system. It meets user demands fully in different environments. System composition could be from single controller to hundreds of controllers. System scalability is strong and flexible. 4.1 RS232 serial If the distance between the controller and the monitor computer is less than fifteen meters, it is best to choose RS232 serial communication. The system composition diagram shows as below. Operation steps: 1. Connect the controller to the monitor computer with rs232 serial port cable. 2. Start the software, set area and node, the interface type should be Com and select the corresponding com port. 3. Restart the software, the software begins to sample data automatically. For computers without serial ports, such as laptops, you can use the usb to serial converters as the communication cable. Note: Recommended to use the computer with serial port for long-term data acquisition. 4.2 RS485 serial system For long distance monitoring it can be set up with a RS485 data collection system. The system composition diagram shows as below. A. Monitor a single controller with rs485 interface Operation steps: 1 Connect the controller with rs485 interface to the monitor computer with rs485 to rs232 converters. Otherwise you can install the rs485 repeaters to extend the communication distance.

25 4 System Integration and Configuration 2/10 2 Start the software, set area and node, the interface type should be Com and select the corresponding com port. 3 Restart the software, the software begins to sample data automatically. B. Monitor several controllers with rs485 interface at the same time Operation steps: 1. Following the operation steps in the A part above to set an area and a node. Connect the controllers to computer one by one, set the device id of all controllers to be different with one another, because the id of device should be unique in the same rs485 bus. 2. Connect all controllers to monitor computer in parallel with one rs485 to rs232 converters, add an area and a node, the interface type should be 485 bus, select the corresponding com port and the device id can keep the default. 3. Restart the software, click the node added in the step 2, the rs485 node searching tool will appear at the upper of the window as below. Input the corresponding com port, begin address and end address. All the device id of controllers should be contained in the range of begin address to end address. Click Search button to search all the controllers in the 485 bus. 4. After the searching process finishes, restart the software, the nodes of controllers searched will be shown in the area & nodes list at the right hand side of the window. The software begins to sample data automatically. 4.3 Local multi-serial port monitoring system Through Multi-serial-port Card user can set up multi controllers monitoring system. Currently popular Multi-serialport Card is PCI bus interface card. The multi-serial port monitoring system diagram shows as below. Operation steps: 1. Shut down monitoring computer, and then install the multi-serial-port card to computer PCI slots. 2. Start the computer, and then install the multi-serial-port card drive, virtual serial ports will be generated in the computer. 3. Connect controllers to multi-serial-port card with rs232 communication cable. Start the software, set area and nodes, the interface type should be Com, select the corresponding com port. 4. Restart the software, the software begins to sample data automatically. 4.4 Local area network monitoring system

26 4 System Integration and Configuration 3/10 Choosing the controller with network interface or the serial server produced by our company can directly connect the controller to the Internet, and realize the local area network monitor. The local area network monitoring system diagram shows as below. Operation steps: 1 Connect the serial server and a computer for configuring to the same router with Ethernet cable. The way to get IP address of the computer should be configured to get dynamic IP from router. 2. Power on the serial server, and then start the configuration software in the computer, the interface of the software shows as below.

27 4 System Integration and Configuration 4/10 Input 1 to select the first item of menu. The software will search the serial server in the local network and list their information in the interface. 3. Select the second item of the menu and input an IP address in the list to configure the serial server parameters.

28 4 System Integration and Configuration 5/10 4. Select the item you need to change in the list above to modify the configuration. If there is more than one serial server in the same monitoring system, you have to change the MAC address of all servers to be different with one another. And the remote IP address should be the same as the IP address of the monitoring computer. Remote port address should be changed to Other parameters need not to be changed just same as shown in the picture above. Input S to make modifications come to effect. 5. After configuring is done. Connect the controller with serial port interface to the serial server with rs232 serial port cable. Connect the serial server to a router in the local area network. The DHCP service of the router has to be started to assign IP address to computer dynamically. 6. Select a computer in the local area network as monitoring computer whose IP address should be the same as the remote IP address in the serial server. Start monitoring software in the computer, configure area and node, the interface type should be Serial Server (WM). Input Module ID and Password which are labeled on the serial server. 7. Restart the software, the software begins to sample data automatically. Note: For the controller with network interface, the serial server just is installed inside the controller. Please refer to the operation steps above to configure. 4.5 Wired remote network monitoring system By choosing the serial server and cloud server developed by our company or the universal serial server such as CNS311, you can connect the controller to the Internet, and realize the remote network monitor. A. Remote network monitoring system based of the serial server and cloud server developed by our company. The system diagram shows as below.

29 4 System Integration and Configuration 6/10 Operation steps: 1. Connect the controller with serial port interface to the serial server with rs232 serial port cable. Connect the serial server to a router. Power on the serial server. 2. Start the monitoring software in the remote monitor computer. Configure area and nodes, the interface type should be WM Server. Input Module ID and Password which are labeled on the serial server if the server is used first time. After the node logins the remote server, you can change the Password in the area and node setting interface. 3. Restart the software, the node will login the remote server automatically and begin to sample data. Note: The router connected with the serial server should access to Internet and the DHCP service has to be started to assign IP address to computer dynamically. The remote monitor computer should have access to Internet. For the controller with network interface, the serial server just is installed inside the controller. Please refer to the operation steps above to configure. B. Remote network monitoring system based of the universal serial server such as CNS311. The system diagram shows as below.

30 4 System Integration and Configuration 7/10 Operation steps: 1. The universal serial server configuration (for CNS311 here) 1> Select a computer for configuring the CNS311, and configure the IP address of the computer to be static and under the same subnet with the CNS311. The default IP address of CNS311 is , the default subnet mask is Connect the CNS311 to the computer with Ethernet cable. Power on the CNS311. 2> Run CNS311 Config Tool in the computer under the same local area network with CNS311. Click Refresh Device List button to search the CNS311 device in the local area network and list them in the device list. Select a device in the list, then click read button to read parameters of the device selected and show them at the right hand side of the window.

31 4 System Integration and Configuration 8/10 3> Select the parameter in the list, then input value in the edit box or down-list box at the upper right of the interface. Click Write button to save the modification. To make the modification come into effect, you have to reset the device by clicking reset button or power on it second time. The parameters should be configured as following. Parameter Name Mac address Auto get IP IP address Subnet mask Gateway IP address Net mode Remote IP/domain Value Not same value for each device Close The static IP address of device in the local area network where the device will work The same value as subnet mask of the local area network where the device will work The gateway IP address of the local area network where the device will work TCP client 1. The public IP address of the local area network where monitor computer works should be filled if the device and monitor computer are not in the same network.. 2. The static IP address of monitor computer

32 4 System Integration and Configuration 9/10 1. Monitoring center configuration If network type is small LAN -> router -> ADSL and then make configuration of router. Open the service port 64000, bind it to LAN IP of the computer running monitoring software. Start the software in the monitor computer, configure area and node, the interface should be Serial Server. Input the device IP. If monitoring the controller in the LAN, the device IP should be the static IP of serial server. If monitoring the controller in the WAN, the device IP should be the public IP of serial server. If use the way of domain name, have to install the dynamic DNS client-side and run it in the monitor computer. 3. Restart monitoring software, the software begins to sample data automatically. 4.6 GPRS monitoring system should be filled if the device and monitor computer work in the same local area network. 3. If use the way of domain name, then fill out the domain name instead. Remote Port number Local Port number Serial Port Mode Transparent mode Baud rate 9600 Data Option Flow control Packet end char 8N1 Close Packet interval 1 null For scattered area, it can realize remote wireless monitoring through the GPRS DTU and cloud server developed by our company. The system diagram shows as below Operation steps: 1. Insert the SIM card opened GPRS data transmission function to the card slot of GPRS DTU, connect the controller to GPRS DTU via rs232 serial port cable and power on the DTU. 2. Start the monitoring software in the monitor computer. Select Parameters Setting->Area & Node Setting, add area and node, the interface type is WM Server, Input Module ID and Password which are labeled on the GPRS DTU if it is used first time. After the node logins the remote server, you can change the Password in the area and node setting interface. 3. Restart the software, the node will login the remote server automatically and begin to sample data.

33 4 System Integration and Configuration 10/ Mixed monitoring system For the monitoring systems which have different communication ways and scattered places, all-in-one mixed monitoring is accepted. It is made up of RS232/485 serial port ways, wired communication ways, GPRS wireless communication ways etc. It can centralize several monitoring system. The system diagram shows as below. Configuration steps please refer to above.

34 4 1/1 4.1 RS232 serial If the distance between the controller and the monitor computer is less than fifteen meters, it is best to choose RS232 serial communication. The system composition diagram shows as below. Operation steps: 1. Connect the controller to the monitor computer with rs232 serial port cable. 2. Start the software, set area and node, the interface type should be Com and select the corresponding com port. 3. Restart the software, the software begins to sample data automatically. For computers without serial ports, such as laptops, you can use the usb to serial converters as the communication cable. Note: Recommended to use the computer with serial port for long-term data acquisition.

35 4 1/1 4.2 RS485 serial system For long distance monitoring it can be set up with a RS485 data collection system. The system composition diagram shows as below. A. Monitor a single controller with rs485 interface Operation steps: 1 Connect the controller with rs485 interface to the monitor computer with rs485 to rs232 converters. Otherwise you can install the rs485 repeaters to extend the communication distance. 2 Start the software, set area and node, the interface type should be Com and select the corresponding com port. 3 Restart the software, the software begins to sample data automatically. B. Monitor several controllers with rs485 interface at the same time Operation steps: 1. Following the operation steps in the A part above to set an area and a node. Connect the controllers to computer one by one, set the device id of all controllers to be different with one another, because the id of device should be unique in the same rs485 bus. 2. Connect all controllers to monitor computer in parallel with one rs485 to rs232 converters, add an area and a node, the interface type should be 485 bus, select the corresponding com port and the device id can keep the default. 3. Restart the software, click the node added in the step 2, the rs485 node searching tool will appear at the upper of the window as below. Input the corresponding com port, begin address and end address. All the device id of controllers should be contained in the range of begin address to end address. Click Search button to search all the controllers in the 485 bus. 4. After the searching process finishes, restart the software, the nodes of controllers searched will be shown in the area & nodes list at the right hand side of the window. The software begins to sample data automatically.

36 4 1/1 4.3 Local multi-serial port monitoring system Through Multi-serial-port Card user can set up multi controllers monitoring system. Currently popular Multi-serialport Card is PCI bus interface card. The multi-serial port monitoring system diagram shows as below. Operation steps: 1. Shut down monitoring computer, and then install the multi-serial-port card to computer PCI slots. 2. Start the computer, and then install the multi-serial-port card drive, virtual serial ports will be generated in the computer. 3. Connect controllers to multi-serial-port card with rs232 communication cable. Start the software, set area and nodes, the interface type should be Com, select the corresponding com port. 4. Restart the software, the software begins to sample data automatically.

37 4 1/3 4.4 Local area network monitoring system Choosing the controller with network interface or the serial server produced by our company can directly connect the controller to the Internet, and realize the local area network monitor. The local area network monitoring system diagram shows as below. Operation steps: 1 Connect the serial server and a computer for configuring to the same router with Ethernet cable. The way to get IP address of the computer should be configured to get dynamic IP from router. 2. Power on the serial server, and then start the configuration software in the computer, the interface of the software shows as below.

38 4 2/3 Input 1 to select the first item of menu. The software will search the serial server in the local network and list their information in the interface. 3. Select the second item of the menu and input an IP address in the list to configure the serial server parameters.

39 4 3/3 4. Select the item you need to change in the list above to modify the configuration. If there is more than one serial server in the same monitoring system, you have to change the MAC address of all servers to be different with one another. And the remote IP address should be the same as the IP address of the monitoring computer. Remote port address should be changed to Other parameters need not to be changed just same as shown in the picture above. Input S to make modifications come to effect. 5. After configuring is done. Connect the controller with serial port interface to the serial server with rs232 serial port cable. Connect the serial server to a router in the local area network. The DHCP service of the router has to be started to assign IP address to computer dynamically. 6. Select a computer in the local area network as monitoring computer whose IP address should be the same as the remote IP address in the serial server. Start monitoring software in the computer, configure area and node, the interface type should be Serial Server (WM). Input Module ID and Password which are labeled on the serial server. 7. Restart the software, the software begins to sample data automatically. Note: For the controller with network interface, the serial server just is installed inside the controller. Please refer to the operation steps above to configure.

40 4 1/4 4.5 Wired remote network monitoring system By choosing the serial server and cloud server developed by our company or the universal serial server such as CNS311, you can connect the controller to the Internet, and realize the remote network monitor. A. Remote network monitoring system based of the serial server and cloud server developed by our company. The system diagram shows as below. Operation steps: 1. Connect the controller with serial port interface to the serial server with rs232 serial port cable. Connect the serial server to a router. Power on the serial server. 2. Start the monitoring software in the remote monitor computer. Configure area and nodes, the interface type should be WM Server. Input Module ID and Password which are labeled on the serial server if the server is used first time. After the node logins the remote server, you can change the Password in the area and node setting interface. 3. Restart the software, the node will login the remote server automatically and begin to sample data. Note: The router connected with the serial server should access to Internet and the DHCP service has to be started to assign IP address to computer dynamically. The remote monitor computer should have access to Internet. For the controller with network interface, the serial server just is installed inside the controller. Please refer to the operation steps above to configure. B. Remote network monitoring system based of the universal serial server such as CNS311. The system diagram

41 4 2/4 shows as below. Operation steps: 1. The universal serial server configuration (for CNS311 here) 1> Select a computer for configuring the CNS311, and configure the IP address of the computer to be static and under the same subnet with the CNS311. The default IP address of CNS311 is , the default subnet mask is Connect the CNS311 to the computer with Ethernet cable. Power on the CNS311. 2> Run CNS311 Config Tool in the computer under the same local area network with CNS311. Click Refresh Device List button to search the CNS311 device in the local area network and list them in the device list. Select a device in the list, then click read button to read parameters of the device selected and show them at the right hand side of the window.

42 4 3/4 3> Select the parameter in the list, then input value in the edit box or down-list box at the upper right of the interface. Click Write button to save the modification. To make the modification come into effect, you have to reset the device by clicking reset button or power on it second time. The parameters should be configured as following. Parameter Name Mac address Auto get IP IP address Subnet mask Gateway IP address Net mode Remote IP/domain Value Not same value for each device Close The static IP address of device in the local area network where the device will work The same value as subnet mask of the local area network where the device will work The gateway IP address of the local area network where the device will work TCP client 1. The public IP address of the local area network where monitor computer works should be filled if the device and monitor computer are not in the same network.. 2. The static IP address of monitor computer

43 4 4/4 1. Monitoring center configuration If network type is small LAN -> router -> ADSL and then make configuration of router. Open the service port 64000, bind it to LAN IP of the computer running monitoring software. should be filled if the device and monitor computer work in the same local area network. 3. If use the way of domain name, then fill out the domain name instead. Remote Port number Local Port number Serial Port Mode Transparent mode Baud rate 9600 Data Option Flow control Packet end char Start the software in the monitor computer, configure area and node, the interface should be Serial Server. Input the device IP. If monitoring the controller in the LAN, the device IP should be the static IP of serial server. If monitoring the controller in the WAN, the device IP should be the public IP of serial server. If use the way of domain name, have to install the dynamic DNS client-side and run it in the monitor computer. 3. Restart monitoring software, the software begins to sample data automatically. 8N1 Close Packet interval 1 null

44 4 1/1 4.6 GPRS monitoring system For scattered area, it can realize remote wireless monitoring through the GPRS DTU and cloud server developed by our company. The system diagram shows as below Operation steps: 1. Insert the SIM card opened GPRS data transmission function to the card slot of GPRS DTU, connect the controller to GPRS DTU via rs232 serial port cable and power on the DTU. 2. Start the monitoring software in the monitor computer. Select Parameters Setting->Area & Node Setting, add area and node, the interface type is WM Server, Input Module ID and Password which are labeled on the GPRS DTU if it is used first time. After the node logins the remote server, you can change the Password in the area and node setting interface. 3. Restart the software, the node will login the remote server automatically and begin to sample data.

45 4 1/1 4.7 Mixed monitoring system For the monitoring systems which have different communication ways and scattered places, all-in-one mixed monitoring is accepted. It is made up of RS232/485 serial port ways, wired communication ways, GPRS wireless communication ways etc. It can centralize several monitoring system. The system diagram shows as below. Configuration steps please refer to above.

46 5 FAQ 1/1 5 FAQ 5.1 No data display when serial port collecting Display real time electrical quantities in the bottom of tendency chart, if data display is always 0.0, please check status indicator light in the bottom right corner. If communication indicator light is yellow and display communication no signal, that is communication bug possibly, user should check serial port s hardware connection and serial port setting of parameters setting. If both connection and setting are correct, please check whether the controller is powered up correctly. 5.2 No operating right For the parameters setting and staff management, dialog box about operating right may pop out, user can switch to the user in the menu who has related right to operate again. 5.3 GPRS can not collect data after collecting for a while Check whether network environment is changed or not, whether SIM is overdue or not. 5.4 Data can not be collected after setting Area and Node After setting Area and Node, system should restart the software. 5.5 Still pictures with USB to serial port module collecting If use serial port collecting, it is recommended to use PC with serial port. If use USB virtual serial port, the software may not read data successfully as USB virtual serial port is unstable. 5.6 Vista/Windows7 system saving data fault Vista and Windows7 system strengthens user permission management. At the configuration area panel port, software need read-write magnetic disk file when outputting Excel file, if user has no writing magnetic disk authorization, will cause software running abnormal, so it is necessary to assign software writing magnetic disk authorization. For that how to assign permission under Vista, Windows 7 system, please refer to related documents.

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2 User Manual MPPTracker Management Software for Solar Charge Controller Version: 1.2 Table of Contents 1. MPPTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. MPPTracker Install and Uninstall...

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for SP Efecto / SP Brilliant (Plus) / SP Initial Table of Contents 1. WatchPower Overview...1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install

More information

User Manual for Solar Station Monitor

User Manual for Solar Station Monitor User Manual for Solar Station Monitor 1. Introduction As a piece of PC terminal software developed by Shenzhen Shuori New Energy Technology Co., Ltd., the software of solar station monitor can be set through

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

Winpower. User Manual

Winpower. User Manual Winpower User Manual Table of Contents Chapter 1 Winpower Introduction ----------------------------------------------------- 4 1. Winpower profile... 4 2. Winpower Structure... 4 3. Winpower Application

More information

SolarPower Pro. User s Manual. Management Software for Solar Inverter

SolarPower Pro.  User s Manual. Management Software for Solar Inverter SolarPower Pro User s Manual Management Software for Solar Inverter Table of Contents 1. SolarPower Pro Overview... 2 1.1. Introduction... 2 1.2. Structure... 2 1.3. Features... 3 2. SolarPower Pro Install

More information

AP-ENBD User Manual V0.2

AP-ENBD User Manual V0.2 AP-ENBD User Manual V0.2 2015/12 Catolog Catolog... 2 1 Introduction... 1 1.1 Communication Structure... 1 1.2 Internal Principle... 2 2 Installation... 2 2.1 Connect to the Same Router (or Switch )...

More information

Quick Installation Manual

Quick Installation Manual Quick Installation Manual FOR ROUTER Enterprise High Power Outdoor Wireless Access Point NETQ-6000 PC Laptop IPAD Thank you for purchasing Enterprise High Gain wireless Router. This manual will instruct

More information

NVMS User Manual

NVMS User Manual NVMS-1000 User Manual Contents 1 Software Introduction...1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall the Software...

More information

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5 User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 6. Specifications... 8 1. Introduction The ServerLink PDU is a network

More information

ShineNet. Growatt Version Date Notes New. ShineNet V1.0

ShineNet. Growatt Version Date Notes New. ShineNet V1.0 ShineNet Growatt 1.0 2012-09-25 Version Date Notes 1.0.0.2 2012-09-25 New Table of Contents 1. Introduction...3 2. Install and Uninstall...4 2.1 System requirements...4 2.2 Install software...4 2.3 Uninstall

More information

1 Hardware Installation

1 Hardware Installation 1 Hardware Installation 1.1 Choosing the Best Location for Wireless Operation Many environmental factors may affect the effective wireless function of the DSL Router. If this is the first time that you

More information

NVMS-5000 NVMS User Manual

NVMS-5000 NVMS User Manual NVMS-5000 NVMS-5000 User Manual NVMS-5000 User Manual Contents 1 Introduction... 4 1.1 NVMS-5000 Brief Introduction... 4 1.1.1 Summerization... 4 1.1.2 Software Architecture... 4 1.2 System Components...

More information

OUTDOOR IR NETWORK CAMERA Series

OUTDOOR IR NETWORK CAMERA Series OUTDOOR IR NETWORK CAMERA Series INSTALLATION GUIDE Please read instructions thoroughly before operation and retain it for future reference. 1. OVERVIEW 1.1 Package Content Network camera Installation

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide DL-200 Cellular Data logger V1.2_201610 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 4 1.1 CONTENTS LIST... 5 1.2 HARDWARE INSTALLATION... 6 1.2.1 WARNING... 6 1.2.2 SYSTEM REQUIREMENTS...

More information

ivms-4200 Access Control Client User Manual UD00895N

ivms-4200 Access Control Client User Manual UD00895N ivms-4200 Access Control Client User Manual UD00895N User Manual About this Manual This Manual is applicable to ivms-4200 Access Control Client. The Manual includes instructions for using and managing

More information

User s Manual. Management Software for Uninterruptible Power Supply Systems

User s Manual. Management Software for Uninterruptible Power Supply Systems ViewPowerMini User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPowerMini Overview...2 1.1. Introduction...2 1.2. Structure...3 1.3. Features...3 2. ViewPowerMini

More information

INSTALLATION INSTRUCTION MANUAL

INSTALLATION INSTRUCTION MANUAL Megapixel IP PTZ Camera INSTALLATION INSTRUCTION MANUAL 1 Contents How to Install and Configure Mezory IP PTZ Camera.. 3 Installing MEZORY IP PTZ Camera... 4 Finding the IP Address... 6 Access and Configure

More information

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any This product can be set up using any current web browser, i.e., Internet Explorer 6x or Netscape Navigator 7x. DSL-G624T Wireless ADSL Router Before You Begin 1. If you purchased this Router to share your

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Standalone DVR User s Manual. Figure 4-81

Standalone DVR User s Manual. Figure 4-81 Figure 4-81 4.11.2 Network 4.11.2.1 TCP/IP The single network adapter interface is shown as in Figure 4-82 and the dual network adapters interface is shown as in Figure 4-83 Network Mode : Includes multiple

More information

Video Surveillance Management Software NVClient V5 User Manual

Video Surveillance Management Software NVClient V5 User Manual Video Surveillance Management Software NVClient V5 User Manual Version: V5.0 Update Date: 2013-12-12 Welcome Thanks for using the Company's digital video surveillance management software. Please read this

More information

DDNS UPNP

DDNS UPNP PL-ADR0608/16-H2 PL-ADR0604-H2 Content 1 Product Introduction... 3 2 Installation... 3 2.1 Open-package Inspection... 3 2.2 Hard Disk Installation... 3 3. Local operation guide... 3 3.1 Boot operation...

More information

F Series Indoor Fixed IP Camera. Quick Start Guide

F Series Indoor Fixed IP Camera. Quick Start Guide F Series Indoor Fixed IP Camera Quick Start Guide Welcome Thank you for purchasing our IP camera! Before install and use the IP camera, please read the following section carefully. Please keep this start

More information

Centralised monitoring software. (version v2.35) Program installation and configuration

Centralised monitoring software. (version v2.35) Program installation and configuration Centralised monitoring software (version v2.35) Program installation and configuration The purpose of the document This document describes the installation and configuration process of program package

More information

3G Router 431R/421R/321R/311R/221R/211R. Quick Start Guide

3G Router 431R/421R/321R/311R/221R/211R. Quick Start Guide 3G Router 431R/421R/321R/311R/221R/211R ---------------------------------------------------------- Version: 2.0----------------------------------------------------------- Check Package Contents: 3G Router

More information

BST-DL114 / BST-DL115/BST-DL116/BST-DL117 Wireless Monitor Temperature Humidity Data Logger. Manual V1.0

BST-DL114 / BST-DL115/BST-DL116/BST-DL117 Wireless Monitor Temperature Humidity Data Logger. Manual V1.0 BST-DL114 / BST-DL115/BST-DL116/BST-DL117 Wireless Monitor Temperature Humidity Data Logger Manual V1.0 CONTENTS Chapter I product introduction... 1 1.1 Product Features... 1 1.2 Range of Application...

More information

NVMS1000. User Manual

NVMS1000. User Manual NVMS1000 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall the Software...

More information

USER MANUAL WINATEQ300 SOFTWARE Full version 1.01

USER MANUAL WINATEQ300 SOFTWARE Full version 1.01 USER MANUAL WINATEQ300 SOFTWARE Full version 1.01 Reference: UM-Winateq300Fa-U AVERTISSEMENTS This document and the software which is provided with it are the exclusive property of ATEQ. The Winateq300

More information

WebAdvantage Overview WebAdvantage is an Internet-based remote monitoring service that allows you to: View real-time controller operating data Change

WebAdvantage Overview WebAdvantage is an Internet-based remote monitoring service that allows you to: View real-time controller operating data Change WebAdvantage and the World Wide Web Keep You in Constant Contact 128 Bit Encryption Server Security Back-up Assured History Storage No Proprietary Software to Load Log in From Any Computer with Internet

More information

Multi-Function Smart Indicator User Manual

Multi-Function Smart Indicator User Manual Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...

More information

Qbox User Manual. Version 7.1

Qbox User Manual. Version 7.1 Qbox User Manual Version 7.1 Index Page 3 Page 6 Page 8 Page 9 Page 10 Page 12 Page 14 Page 15 Introduction Setup instructions: users creating their own account Setup instructions: invited users and team

More information

XL-PB350CA. EoC bridge slave. User manual

XL-PB350CA. EoC bridge slave. User manual XL-PB350CA EoC bridge slave User manual Content 1. Equipment Connection... 6 2. Set Accessed PC... 6 3.WIFI WEB Configuration... 8 3.1 Login WEB Interface... 8 3.2 WAN Configuration... 10 3.2.1 PPPO E

More information

WRE6606. User s Guide. Quick Start Guide. Dual-Band Wireless AC1300 Access Point. Default Login Details. Version 1.00 (ABDU.0) Edition 1, 10/2016

WRE6606. User s Guide. Quick Start Guide. Dual-Band Wireless AC1300 Access Point. Default Login Details. Version 1.00 (ABDU.0) Edition 1, 10/2016 WRE6606 Dual-Band Wireless AC1300 Access Point Version 1.00 (ABDU.0) Edition 1, 10/2016 Quick Start Guide User s Guide Default Login Details Web Address http://zyxelsetup http://dhcp-assigned IP www.zyxel.comhttp://192.168.1.2

More information

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5 PREPARATION...5 CONFIGURATION SOLUTION TABLE...5

More information

IP Device Search and Configuration Tool Operation Manual

IP Device Search and Configuration Tool Operation Manual IP Device Search and Configuration Tool Operation Manual Note Copyright Statement This manual may not be reproduced in any form or by any means used to create any derivative such as translation, transformation,

More information

LonHand series product specification

LonHand series product specification LonHand series product specification USR-WIFIIO-83 File Version: V1.4 Jinan USR IOT Technology Limited 1 / 29 tec@usr.cn Content LonHand series product specification... 1 Content... 2 1. Quick start...

More information

NVMS User Manual

NVMS User Manual NVMS-1000 User Manual Contents 1 Software Introduction...1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall the Software...

More information

GHz g. Wireless A+G. User Guide. Notebook Adapter. Dual-Band. Dual-Band WPC55AG a. A Division of Cisco Systems, Inc.

GHz g. Wireless A+G. User Guide. Notebook Adapter. Dual-Band. Dual-Band WPC55AG a. A Division of Cisco Systems, Inc. A Division of Cisco Systems, Inc. Dual-Band 5 GHz 802.11a + GHz 2.4 802.11g WIRELESS Dual-Band Wireless A+G Notebook Adapter User Guide Model No. WPC55AG Copyright and Trademarks Specifications are subject

More information

User Manual MPPTracker

User Manual MPPTracker User Manual MPPTracker Management Software for Solar Charge Controller Version: 1.0 Table of Contents 1. MPPTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. MPPTracker Install and Uninstall...

More information

ID

ID CATLOG 1. Use notice... 1 1.1 the recommended procedure in the first using... 1 1.2 Button description... 2 2. User Management... 3 2.1 User Registration... 3 2.1.1 Fingerprint registration... 4 2.1.2

More information

Quick Start Guide (V1.03) UD.6L0201B1064A01

Quick Start Guide (V1.03) UD.6L0201B1064A01 ivms-4200 PCNVR Quick Start Guide (V1.03) UD.6L0201B1064A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact the dealer. This manual applies

More information

NETWORK LAB 2 Configuring Switch Desktop

NETWORK LAB 2 Configuring Switch Desktop Configuring Switch 1. Select the switch tab and then add a switch from the list of switches we have to the workspace, we will choose (2950-24) switch. 2. Add a number of PCs next to the switch in order

More information

Computer Management* (IEA) Training Foils

Computer Management* (IEA) Training Foils Intel-powered classmate PC Computer Management* (IEA) Training Foils Version 1.0 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

DMS Local. User Manual. For Projector Management V 1.01

DMS Local. User Manual. For Projector Management V 1.01 DMS Local User Manual For Projector Management V 1.01 2 Copyright Copyright Copyright 2018 BenQ Corporation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

DP-502 User s Guide Harware Descriptions Software Installation ETM 3.0

DP-502 User s Guide Harware Descriptions Software Installation ETM 3.0 DP-502 User s Guide This DP-502 (the device ) based system allows multiple devices to connect to a server and automatically update audio contents on a daily basis. The device is loaded with up to 13 sound

More information

Manual Version: V1.15. Video Management Software Guard Station User Manual

Manual Version: V1.15. Video Management Software Guard Station User Manual Manual Version: V1.15 Video Management Software Guard Station User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Disclaimer

More information

User Manual. BioTime Web

User Manual. BioTime Web BioTime Web Version: 1.0 Date: December 2016 BioTime Web Index 1. Quick Start... 2 1.1. Overview... 2 1.2. Finger Placement... 3 1.3. How to use touch screen... 3 1.4. Recommended Operation Steps... 4

More information

Click on Close button to close Network Connection Details. You are back to the Local Area Connection Status window.

Click on Close button to close Network Connection Details. You are back to the Local Area Connection Status window. How to configure EW-7228APn/EW-7416APn as a Repeater to extend wireless range This article can apply on EW-7228APn and EW-7416APn. We used screen shots of EW-7416APn in this instruction. We recommend you

More information

A Division of Cisco Systems, Inc. GHz g. Wireless-G. PCI Adapter with SRX 400. User Guide WIRELESS WMP54GX4. Model No.

A Division of Cisco Systems, Inc. GHz g. Wireless-G. PCI Adapter with SRX 400. User Guide WIRELESS WMP54GX4. Model No. A Division of Cisco Systems, Inc. GHz 2.4 802.11g WIRELESS Wireless-G PCI Adapter with SRX 400 User Guide Model No. WMP54GX4 Copyright and Trademarks Specifications are subject to change without notice.

More information

NVMS1000. User Manual

NVMS1000. User Manual NVMS1000 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall the Software...

More information

Model:BL-WR Mbps Wireless N Router

Model:BL-WR Mbps Wireless N Router Quick Installation Guide Model:BL-WR3000 300Mbps Wireless N Router 1.Connecting the device Note: Please use wired network connections only to configure the Router. 1 Connect the WAN port on your Router

More information

I-Fly Wireless Broadband Router

I-Fly Wireless Broadband Router with 4 Fast Ethernet ports + 1 Wan port Quick Start Guide A02-WR-54G/G2 (November 2003)V1.00 For more detailed instructions on configuring and using the I- Storm Lan Router ADSL, please refer to the online

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system.

Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system. Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system. Please follow these steps to ensure that any changes made by your previous

More information

A Division of Cisco Systems, Inc. GHz 2, g. Wireless-G. User Guide. PCI Adapter WIRELESS. with SpeedBooster WMP54GS (EU/UK/LA) Model No.

A Division of Cisco Systems, Inc. GHz 2, g. Wireless-G. User Guide. PCI Adapter WIRELESS. with SpeedBooster WMP54GS (EU/UK/LA) Model No. A Division of Cisco Systems, Inc. GHz 2,4 802.11g WIRELESS Wireless-G PCI Adapter with SpeedBooster User Guide Model No. WMP54GS (EU/UK/LA) Copyright and Trademarks Specifications are subject to change

More information

Table of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4

Table of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4 Table of Contents 1. Intended Use.. 3 2. Overview.. 3 2.1 Materials Required. 3 2.2 System Requirements. 3 2.3 User Mode 4 3. Installation Instructions.. 5 3.1 Installing the On Call Diabetes Management

More information

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3

More information

RPM Utility Software. User s Manual

RPM Utility Software. User s Manual RPM Utility Software User s Manual Table of Contents 1. Introduction... 1 2. Installation... 2 3. RPM Utility Interface... 4 1. Introduction General RPM Utility program is an RPM monitoring, and management

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

User Manual SolarTracker

User Manual SolarTracker User Manual SolarTracker Management Software for Inverter Table of Contents 1. SolarTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. SolarTracker Install and Uninstall... 1 2.1. System

More information

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0 Network USB over IP Server With 1-USB2.0 Port User Manual V1.0 1 2 TABLE OF CONTENTS COPYRIGHT...4 1. INTRODUCTION...5 PRODUCT OVERVIEW...5 COMPONENTS AND FEATURES...5 HARDWARE INSTALLATION...5 2. THE

More information

802.11g Wireless LAN MFP Server

802.11g Wireless LAN MFP Server 802.11g Wireless LAN MFP Server Quick Installation Guide Version: 1.0 (Jun. 2009) 1. Product Introduction Thank you for purchasing and using our 802.11g Wireless LAN MFP server. This MFP server allows

More information

Contents. Chapter 1 Product Introduction Package Contents Product Features Product Usage... 2

Contents. Chapter 1 Product Introduction Package Contents Product Features Product Usage... 2 Contents Chapter 1 Product Introduction... 2 1.1 Package Contents... 2 1.2 Product Features... 2 1.3 Product Usage... 2 1.4 Before Installation... 3 1.5 Disable other manufacturers wireless network adapters...

More information

Super Parameter Programmer SPP-01

Super Parameter Programmer SPP-01 Super Parameter Programmer SPP-01 Dear user: Thank you very much for selecting our product! This manual offers important information and suggestions about use and troubleshooting, etc. Please read this

More information

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command OPERATION MANUAL MV-410HS Layout Editor Version 3.0 - higher Command Command Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410HS

More information

CMS IP Software Documentation

CMS IP Software Documentation CMS IP Software Documentation Documentation Version August 2012 General Description. The CMS-IP software is used in conjunction with the L7700 IP Controller and displays real time information from the

More information

PDU Utility. User Manual

PDU Utility. User Manual PDU Utility User Manual Table of Contents 1. Introduction... 1 2. Installation... 2 3. PDU Utility Interface... 4 1. Introduction General PDU Utility is PDU monitoring, management software. It has been

More information

INSTRUCTION MANUAL ABB Power Quality Link Installation and user guide

INSTRUCTION MANUAL ABB Power Quality Link Installation and user guide INSTRUCTION MANUAL ABB Power Quality Link Installation and user guide Table of contents 1 Introduction... 4 2 Overview... 4 2.1 Introduction to the ABB Power Quality Link software... 4 2.2 Physical layer...

More information

Setup Guide for Hard-Wire Ethernet Connected TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist

Setup Guide for Hard-Wire Ethernet Connected TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist Setup Guide for Hard-Wire Ethernet Connected TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist Summary This document explains how to configure the TP-Link

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

ST-HVR8704 ST-HVR8708 ST-HVR8716. Professional Digital Video Recorders QUICK START GUIDE

ST-HVR8704 ST-HVR8708 ST-HVR8716. Professional Digital Video Recorders QUICK START GUIDE ST-HVR8704 ST-HVR8708 ST-HVR8716 Professional Digital Video Recorders QUICK START GUIDE 1 Thank you for purchasing this SecurityTronix Hybrid Video Recorder! The documentation for this HVR comes in 2 formats;

More information

Mini-102MG ( MFP Server) Quick Installation Guide. User's Manual Version : Mini-102MG_QIG_EU-A_V1

Mini-102MG ( MFP Server) Quick Installation Guide. User's Manual Version : Mini-102MG_QIG_EU-A_V1 Mini-102MG ( MFP Server) Quick Installation Guide User's Manual Version : Mini-102MG_QIG_EU-A_V1 1. Product Introduction Thank you for purchasing and using our 802.11b/802.11g Wireless LAN MFP server.

More information

The Administration Tab - Diagnostics

The Administration Tab - Diagnostics The Administration Tab - Diagnostics The diagnostic tests (Ping and Traceroute) allow you to check the connections of your network components. Ping Test. The Ping test will check the status of a connection.

More information

SL620/DS-Tmini Snaplab+ Internet Configuration Setting procedure

SL620/DS-Tmini Snaplab+ Internet Configuration Setting procedure SL620/DS-Tmini Snaplab+ Internet Configuration Setting procedure DNP PIE Nov 2015 V1.1 CONTENTS Introduction... 3 Router Update and Settings for SL-620:... 3 What is new?... 3 1. Updating the existing

More information

CHC HCE320 GNSS Data Controller User Guide

CHC HCE320 GNSS Data Controller User Guide CHC HCE320 GNSS Data Controller User Guide Revision 1.0 8/05/2018 1 Table of Contents Table of Contents Table of Contents... 2 1 Product Introduction... 3 1.1 Brief Introduction... 3 1.2 Product Accessories...

More information

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve

More information

9936A LogWare III. User s Guide. Revision

9936A LogWare III. User s Guide. Revision 9936A LogWare III User s Guide Revision 850701 Table of Contents 1 Introduction...1 1.1 Symbols Used... 1 1.2 Conventions... 1 1.3 What is LogWare?... 1 1.4 License Agreement... 2 1.5 Requirements...

More information

Winpower. User Manual

Winpower. User Manual Winpower User Manual Table of Contents Chapter 1 Winpower Introduction... 4 1. Winpower profile... 4 2. Winpower Structure... 4 3. Winpower Application Range... 5 4. Winpower Functions & Advantages...

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

Packet Tracer Create a Simple Network Using Packet Tracer

Packet Tracer Create a Simple Network Using Packet Tracer Using Packet Tracer Topology Addressing Table Device Interface IP Address Subnet Mask Default Gateway PC Ethernet0 DHCP 192.168.0.1 Wireless Router Cisco.com Server LAN 192.168.0.1 255.255.255.0 Internet

More information

NVMS User Manual. Version 2.1.0

NVMS User Manual. Version 2.1.0 NVMS-1000 User Manual Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

IPAdminTool User s Manual

IPAdminTool User s Manual IPAdminTool User s Manual http://www.rimaelektronik.com 06A.00 www.rivatech.de 1 Table of Contents 1. Introduction...3 1.1. Requirements... 3 1.2. Starting IPAdminTool... 3 1.3. Menu and button configuration...

More information

Solar Monitoring System User Manual

Solar Monitoring System User Manual Solar Monitoring System User Manual 7/2016 V4.3 Catalog 1 Systematic summarize... 1 1.1 System structure... 1 1.2 System function brief... 1 1.3 Performance... 2 1.4 Words explanation... 2 2 Operating

More information

Configuring the network clients

Configuring the network clients 3 Configuring the network clients Accessing the wireless router Setting an IP address for wired or wireless clients To access the ASUS Wireless Router, you must have the correct TCP/IP settings on your

More information

Version: 1.1 Software Version: For Access 4.5.8/5.0.8 and above Version Date: July, 2011

Version: 1.1 Software Version: For Access 4.5.8/5.0.8 and above Version Date: July, 2011 User Manual Version: 1.1 Software Version: For Access 4.5.8/5.0.8 and above Version Date: July, 2011 About This Manual This document introduces the main function, the user interface and operations of the

More information

Brother HL-5370DW Configuration

Brother HL-5370DW Configuration Brother HL-5370DW Configuration Importance of Static IP Address for Printers When a printer is first installed to a computer, its IP address is noted. If that address changes, the computer will be unable

More information

Quick Guide for BlueSoleil Version 6

Quick Guide for BlueSoleil Version 6 LM540 Bluetooth USB Adapter Quick Guide for BlueSoleil Version 6 1. System Requirements At least 50MB of free disk space is required; Windows 7, Windows Vista or Windows XP operating systems are supported.

More information

Sound Manager 2 User Guide

Sound Manager 2 User Guide Sound Manager 2 User Guide Version 1.8.4 September 27 th, 2016 OVERVIEW 2 USER OPERATION 3-6 LOGIN SCREEN 7 OPTIONAL STEP 8-10 MAIN MENU 11 DEVICES TAB 11 ZONE TAB 12 EQ TAB 13 SOURCES TAB 14 SYSTEM TAB

More information

Decoder Firmware B1D-220-V AC User s Manual Decoder Firmware B1D-220-V AC User s Manual

Decoder Firmware B1D-220-V AC User s Manual Decoder Firmware B1D-220-V AC User s Manual Decoder Firmware B1D-220-V3.03.07-AC User s Manual i Table of Contents INTRODUCTION 1 1.1 Minimum system requirements 1 1.2 Preparation before setup 2 1.2.1 Setup your PC network 2 1.3 Configuring the

More information

Dominion KX II-101-V2

Dominion KX II-101-V2 Dominion KX II-101-V2 Quick Setup Guide Thank you for your purchase of the KX II-101-V2, the industry's most full-featured, enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch. This Quick

More information

PMAC770 LAN Module User Manual V1.0

PMAC770 LAN Module User Manual V1.0 PMAC770 LAN Module User Manual V1.0 1 CONTENTS 1. Product Description... 3 1.1 WEB page data... 3 1.2 Functions... 3 1.3 Performance Specifications... 3 2. Installation and Wiring... 4 2.1 Environment...

More information

Centralized Monitoring Management Platform. Manual

Centralized Monitoring Management Platform. Manual Centralized Monitoring Management Platform Manual 3 Contents 1. Products... 5 1.1. Summary... 5 1.2. Application Environment... 5 1.3. Install and uninstall... 6 2. Centralized Monitoring Management Platform

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information