1 IEC Slave to PROFIBUS DP Master Gateway S-PDPM The 101S-PDPM modules are the ideal solution for the many applications where IEC 101 Slave connectivity can be used to integrate a PROFIBUS slave device into a system. The IEC Slave gateway is a powerful module designed with Slave support, enabling easy connection to an IEC 101 master device. In combination with the PROFIBUS DP Master support, the module provides a very powerful interface to the many PROFIBUS DP slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED IEC Slave to PROFIBUS DP Master Gateway S-PDPM The ProLinx IEC Slave to PROFIBUS DP Master Gateway creates a powerful connection between devices on an IEC 101 network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Master configurable DB9F port and one IEC 101 Slave configurable serial port. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset

2 PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Application Serial Ports Serial Port Isolation RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Baud Rate: 9.6 kbit/s 12 Mbit/s Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved December 17, 2013.

3 IEC Slave to PROFIBUS DP Slave Gateway S-PDPS The 101S-PDPS modules are the ideal solution for the many applications where IEC 101 Slave connectivity can be used to integrate a PROFIBUS DP master device into a system. The IEC Slave gateway is a powerful module designed with Slave support, enabling easy connection to 101 master devices. IApplications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Slave to PROFIBUS DP Slave Gateway S-PDPS The ProLinx IEC Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 101 network and a PROFIBUS DP master device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and one IEC 101 Slave configurable serial port. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset

4 PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-PDPS IEC Slave to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

5 IEC Master to PROFIBUS DP Slave Gateway M-PDPS The 103M-PDPS modules are the ideal solution for the many applications where IEC 103 Master connectivity can be used to integrate a PROFIBUS DP master device into a system. The IEC Master gateway is a powerful module designed with Master support, enabling easy connection to other IEC 103 slave devices. In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Master to PROFIBUS DP Slave Gateway M-PDPS The ProLinx IEC Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 103 network and PROFIBUS DP master devices. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and one IEC 103 Master configurable serial port. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address

6 PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: M-PDPS IEC Master to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

7 DATASHEET IEC Server to IEC Master Gateway S-101M The ProLinx IEC Server to IEC Master Gateway creates a powerful connection between IEC 104 server devices on an Ethernet network and IEC Master devices on a serial network. This standalone DIN-rail mounted protocol gateway provides one Ethernet port and one configurable IEC 101 Master serial port. The ProLinx 104S gateway accepts and responds to commands from a network-connected Client (Master) and can also autonomously generate unsolicited messages for cyclic or event-driven data transmission. Firmware versions 3.00 and later support a wider range of IEC Edition 2 data types and Causes of Transmission than previously offered. The ProLinx 101M driver can be configured to act as a IEC Master (controlling unit) communicating with IEC slaves (controlled units) on a serial communication network. The 101M driver supports polling of up to 16 slave devices, up to five sectors per slave, using up to 100 total polling commands. Features Benefits Powerful network integration IEC Server protocol interface IEC Master protocol interface Move data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port Adds an IEC Server (Slave) Input and Output link to an Ethernet network IEC , Edition 2 Data Types and extended Cause of Transmission Support Advanced Event Buffer reporting controls allow better network data bandwidth utilization Supports IEC Master specification: balanced/unbalanced mode, 16 sessions/5 sectors per session, timestamping Individually configurable serial application port Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.

8 General s - ProLinx ProLinx Communication gateways provide connectivity for two or more dissimilar network types. The gateway, enclosed in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. General s 104 Server Operating in Server mode (only), the 104S protocol implementation accepts commands from an IEC Client to read data stored in or write data into the gateway s internal database memory registers. The 104S implementation is also capable of generating unsolicited messages. Unsolicited messages can be either spontaneous (event-driven) or cyclic (timing-driven) communication. The remote Client device uses the fully-configurable gateway memory database to control outputs and monitor inputs to devices on the IEC 104 network. Changes to the gateway database can also be used to transfer monitoring and control data to devices connected to the gateway using another installed network protocol. The 104S gateway thus provides a data transfer solution between an IEC Ethernet network and other serial and Ethernet network protocols, as well as proprietary interfaces. General specifications include: User-definable database memory usage, based on data types and point counts Protocol implementation conforms to the IEC specification with fullyconfigurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions (events) General s Master The 101M module acts as an input/output module between the IEC network and many of the other serial and network protocols, as well as several proprietary interfaces. A 4000-word register space in the module exchanges data between the two protocols. Built in accordance to the approved international specification Support for the storage and transfer of up to 4000 registers between protocols User-definable module memory usage Configuration via a user-generated text file (downloadable to the module) Protocol implementation conforms to the IEC specification with fully configurable parameters Schematic

9 Functional s - IEC Server IEC Server Functional s Supported Message Types Supported Data Types Maximum number of points (per Data Type) Event Message Support Configurable Parameters Accepts Client Monitor and Control Messages Generates Timed Data Transmission Messages Generates Event Data Transmission Messages Supports all Edition 2 Causes of Transmission Monitor Points: M_SP_NA M_DP_NA M_ST_NA M_BO_NA M_ME_NA, NB, & NC M_IT_NA Control Points: C_SC_NA C_DC_NA C_RC_NA C_BO_NA C_SE_NA, NB & NC 500 Points for all Supported Data Types, except 50 Points for Types M_ME_NC and C_SE_NC 4000 total data words, maximum Event Messages with or without Time Stamp Event Buffers up to 99 Events per Data Type Event Report Options: Latest Only or Multiple Restricted IP Address Access List Supports "t0" Ethernet Connection Timeout Data Freeze Start and Freeze Interval Cyclic Data Transmission Time Data Type Priority Queues Data Validity Bit Checking and Timeout Control Bit Pulse On/Off Time And more... Functional s - IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, and so on). The gateway supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 5 sectors (with distinct Common ASDU Addresses) Configurable General Interrogation messages during initialization Time comes from the 104S driver (remote host or NTP server) Supports General Interrogation, General Command and Time Synchronization Commands General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to milliseconds Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.

10 Hardware s Power Supply 24 Vdc nominal 18 to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 500 ma 32 Vdc maximum Operating Temperature -4 F to 122 F (-20 C to 50 C) Storage Temperature Relative Humidity Dimensions (Height x Width x Depth) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) -40 F to 185 F (-40 C to 85 C) 5 to 95% (without condensation) Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols. Serial Port Isolation 2500 Vrms port signal isolation per UL Vdc min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only) Agency Approvals & Certifications culus ISA Class I, Div 2 Groups A, B, C, D culus C22.2 No. 213-M Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: IEC Server to IEC Master Gateway S-101M To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com fax to Europe / Middle East / Africa europe@prosoft-technology.com fax to +33 (0) Copyright 2011 ProSoft Technology, Inc., all rights reserved. April 7th, 2011 s subject to change without notice.

11 IEC Server to IEC Master Gateway S-103M The 104S-103M modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate an IEC 103 slave device into a system. The IEC Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 client devices. In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Electrical Power. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Server to IEC Master Gateway S-103M The ProLinx IEC Server to IEC Master Gateway creates a powerful connection between devices on an IEC 104 network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

12 IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-103M IEC Server to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

13 IEC Server to DF1 Master/Slave Gateway 5201/ S-DFCM(4) The 104S-DFCM modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate DF1 Master/Slave devices into a system. The IEC Server gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 Master/Slave device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Server to DF1 Master/Slave Gateway 5201/ S-DFCM(4) The ProLinx IEC Server to DF1 Master/Slave Gateway creates a powerful connection between devices on an IEC 104 network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

14 DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-DFCM S-DFCM4 IEC Server to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

15 IEC Server to DH-485 Gateway S-DH485 The 104S-DH485 modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate a DH-485 device into a system. The IEC Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED IEC Server to DH-485 Gateway S-DH485 The ProLinx IEC Server to DH-485 Gateway creates a powerful connection between devices on an IEC 104 Server network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

16 DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 16, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

17 IEC Server to DNP 3.0 Slave Gateway S-DNPS The 104S-DNPS modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate DNP 3.0 DF1 Master or Slave devices into a system. The IEC Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Server to DNP 3.0 Slave Gateway S-DNPS The ProLinx IEC Server to DNP 3.0 Slave Gateway creates a powerful connection between devices on an IEC 104 Server network and a DNP master device. This stand-alone DIN-rail mounted protocol gateway provides one DNP 3.0 configurable serial port and one Ethernet port. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

18 DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-DNPS IEC Server to DNP 3.0 Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

19 IEC Server to DNP 3.0 over Ethernet Gateway S-DNPSNET The 104S-DNPSNET modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate DNP 3.0 DF1 Master or Slave devices into a system. The IEC Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DNP over Ethernet device support, the module provides a very powerful interface to the many DNP 3.0 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Server to DNP 3.0 over Ethernet Gateway S-DNPSNET The ProLinx IEC Server to DNP 3.0 over Ethernet creates a powerful connection between devices on an IEC 104 Server network and a DNP device. The module is a stand-alone DIN rail-mounted protocol gateway that provides one Ethernet port. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

20 DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-DNPSNET IEC Server to DNP 3.0 over Ethernet Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

21 IEC Server to Modbus Master/Slave Gateway 5201/ S-MCM(4) The 104S-MCM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC 104 slave device into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC Server device support, the module provides a very powerful interface to the many IEC 104 client devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Server to Modbus Master/Slave Gateway 5201/ S-MCM(4) The ProLinx IEC Server to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus network and an IEC 104 client device. This stand-alone DINrail mounted protocol gateway provides one Ethernet port and up to four serial ports. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. IEC Server Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

22 Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-MCM S-MCM4 IEC Server to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

23 IEC Server to PROFIBUS DP Master Gateway S-PDPM The ProLinx IEC Server to PROFIBUS DP Master Gateways create a powerful connection between devices on an IEC 104 Server network and a PROFIBUS slave device. The module provides one Ethernet port and one PROFIBUS DP Master configurable DB-9F port. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED IEC Server to PROFIBUS DP Master Gateway S-PDPM The IEC Server to PROFIBUS DP Master Gateway creates a powerful connection between devices on an IEC 104 network and a PROFIBUS DP slave. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Master configurable DB9F port and one IEC 104 Server Ethernet port. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fullyconfigured databases in the module to control outputs and monitor inputs.

24 IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Communication Baud Rate: 9.6 kbit/s 12 Mbit/s ProSoft Configuration Builder parameters PROFIBUS Master Command List Node address Status Data Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) Relative 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 18, 2013

25 The IEC Server to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 104 network and PROFIBUS DP Master devices. This stand-alone DIN-rail mounted gateway provides one PROFIBUS DP-V0 Slave DB9F port and one IEC 104 Server Ethernet port. IEC Server to PROFIBUS DP Slave Gateway S-PDPS The 104S gateway accepts and responds to commands from a network-connected Client (Master) and can also autonomously generate unsolicited messages for cyclic or eventdriven data transmission. Firmware versions 3.00 and later support a wider range of IEC Edition 2 data types and Causes of Transmission than previously offered. The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished using the provided ProSoft Configuration Builder software. Features Benefits Powerful network integration Move data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port IEC Server protocol interface Adds an IEC Server (Slave) Input and Output link to a PROFIBUS DP network IEC , Edition 2 Data Types and extended Cause of Transmission Support Advanced Event Buffer control parameters allow better data bandwidth utilization PROFIBUS DP-V0 Slave protocol interface ProSoft Configuration Builder software included Adds PROFIBUS DP Slave device monitoring and control to a IEC network Easy configuration - GSD file provided PROFIBUS Slave status may be stored in gateway database and retrieval by either protocol Graphical drag-and-drop configuration tool for simple module configuration Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics View module database contents through serial connection to a desktop PC Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.

26 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. General s - 104S Server Operating in Server mode (only), the 104S protocol implementation accepts commands from an IEC Client to read data stored in or write data into the gateway s internal database memory registers. The 104S implementation is also capable of generating unsolicited messages. Unsolicited messages can be either spontaneous (event-driven) or cyclic (timing-driven) communication. The remote Client device uses the fully-configurable gateway memory database to control outputs and monitor inputs to devices on the IEC 104 network. Changes to the gateway database can also be used to transfer monitoring and control data to devices connected to the gateway using another installed network protocol. The 104S gateway thus provides a data transfer solution between an IEC Ethernet network and other serial and Ethernet network protocols, as well as proprietary interfaces. General specifications include: User-definable database memory usage, based on data types and point counts Protocol implementation conforms to the IEC specification with fullyconfigurable parameters SNTP (Simple Network Time Protocol) time-stamping for detailed logging of data transactions (events) General s PROFIBUS DP Slave The PROFIBUS DP-V0 Slave driver provides a powerful and easy-to-use interface between a PROFIBUS DP network and other networks. This slave implementation gives access to up to 244 bytes of PROFIBUS Input data and up to 244 bytes of PROFIBUS Output data, with a maximum configurable limit of 400 total data bytes. These Input and Output data areas are fixed in the ProLinx Gateway s data memory, allowing the user to monitor or manipulate this data with either of the installed gateway protocols. Functional s IEC Server Functional s Supported Message Types Supported Data Types Maximum number of points (per Data Type) Event Message Support Configurable Parameters Accepts Client Monitor and Control Messages Generates Timed Data Transmission Messages Generates Event Data Transmission Messages Supports all Edition 2 Causes of Transmission Monitor Points: M_SP_NA M_DP_NA M_ST_NA M_BO_NA M_ME_NA, NB, & NC M_IT_NA Control Points: C_SC_NA C_DC_NA C_RC_NA C_BO_NA C_SE_NA, NB & NC 1000 Points for all Supported Data Types, except 50 Points for Types M_ME_NC and C_SE_NC 4000 total data words, maximum Event Messages with or without Time Stamp Event Buffers up to 99 Events per Data Type Event Report Options: Latest Only or Multiple Restricted IP Address Access List Supports "t0" Ethernet Connection Timeout Data Freeze Start and Freeze Interval Cyclic Data Transmission Time Data Type Priority Queues Data Validity Bit Checking and Timeout Control Bit Pulse On/Off Time And more... Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.

27 PROFIBUS DP Slave Functional s GSD File Communication parameters Supported I/O length Supported PROFIBUS DP-V0 features PRLX05A5.GSD Available on ProSoft Solutions DVD, or downloadable from ProSoft Technology web site Baud Rate: 9.6 kbps to 12 Mbps 244 bytes Input data 244 bytes Output data 400 total data bytes, maximum Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 0 to 125 Data byte swapping Action on loss of PROFIBUS connection Communication Fail Timeout Multiplier Hardware s Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals Current Load 500 ma 32 VDC max Operating Temperature -4 F to 122 F (-20 C to 50 C) Storage Temperature -40 F to 185 F (-40 to 85 C) Relative Humidity 5% to 95% (without condensation) Dimensions Standard: 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm H x 5.25 cm W x 11.48cm D) Extended: 5.20 in H x 2.73 in W x 4.52 in D (13.2 cm H x cm W x 11.48cm D) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) Power & Hardware Fault Configuration & Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10Base-T half-duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 sec, applied as specified in IEC 60950: Section 5.3.2, 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second for less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable Note: The number of serial application ports depends on the gateway type, and the combination of protocols. Serial Port Isolation 2500 V RMS port signal isolation per UL VDC min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable ProSoft Solutions DVD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Copyright 2015 ProSoft Technology, Inc. All rights reserved. August 19, 2015 s subject to change without notice. Agency Approvals & Certifications UL/cUL ISA Class I, Div 2 Groups A, B, C, D cul C22.2 No. 213-M1987

28 IEC Server to Rockwell Automation Remote I/O Gateway S-RIO The ProLinx IEC Server to Rockwell Automation Remote I/O Gateways create a powerful connection between devices on an IEC 104 Server network and Remote I/O devices. The module provides one Ethernet port and one Remote I/O port. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English IEC Server to Rockwell Automation Remote I/O Gateway S-RIO The ProLinx IEC Server to Rockwell Automation Remote I/O creates a powerful connection between devices on an IEC 104 network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. IEC Server Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

29 Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: S-RIO IEC Server to Rockwell Automation Remote I/O Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

30 DATASHEET EtherNet/IP to IEC Client Gateway 5201-DFNT-104C The ProLinx EtherNet/IP to IEC Client gateway creates a powerful connection between an EtherNet/IP network and IEC 104 server devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port. The EtherNet/IP protocol supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a server, the EtherNet/IP port is a very powerful data transfer tool. The IEC client protocol implementation allows the transfer of monitored and control data to remote servers. Features Benefits Powerful network integration Allows movement of data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port EtherNet/IP Client and Server Integrate with widely available Rockwell Automation and 3rd party products and services worldwide Client/server Explicit Messaging communication supported 5 server connections 3 client connections supporting 100 communication commands per client IEC Client 4 connections for remote servers Supports up to 2 Common ASDU Addresses per server Supports monitored and control data Supports up 500 commands to the remote servers Timestamp events are available to the other protocol through the mailbox feature Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.

31 General s - ProLinx ProLinx Communication gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. General s IEC C The ProLinx family EtherNet/IP to IEC Client communications module creates a powerful connection between an EtherNet/IP network and IEC 104 server devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Ethernet port. General s - EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools used by different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol has been implemented to provide asynchronous data transfer between the ProLinx gateway and Rockwell Automation hardware. Supported PLC Types PLC-2, PLC-3, PLC-5, SLC 500, ControlLogix, CompactLogix, and MicroLogix Messaging Types As a Client, PCCC Explicit Messaging As a Server, PCCC or CIP Explicit Messaging Command Sets PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500 Command Set EtherNet/IP Server In server mode, the gateway accepts commands from one or more Clients to read/write data stored in the gateway s internal registers. Number of Connections 5 Supported PLC Types PLC2, PLC5, SLC and ControlLogix file types supported Internal Database Data Table File Size: 100 or 1000 words Data Table File Start: N10 to N109 (based on file size set to 100) or N10 to N19 (based on file set to 1000) Schematic CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client In Client mode, the gateway controls the read/write data transfer between the gateway and other EtherNet/IP devices. Number of Clients Supported 1 Command List Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. Polling of Command List User-configurable polling of commands, including disabled, continuous and on change of data (write only). Other Configurable Parameters Number of Commands (up to 100 per Client) Min Command Delay Response Timeout Retry Count Command Error Pointer

32 Functional s - IEC Client Operating in the Client mode, the gateway generates commands to a server device to read/write data stored in the gateway's internal registers. The IEC Client communication protocol is built in accordance to the approved IEC specification. The gateway functions as a Client on the network supporting monitored and control data from IEC servers on the network. The gateway supports unsolicited messages, either cyclic or spontaneous. The gateway supports clock synchronization commands. The gateway supports Group interrogation (Global, General 1 to 16, Global Counters, Counters 1-4). The gateway supports up to 4 Client connections. Supported Message Types Supported Data Types Maximum number of points (per Data Type) Maximum number of commands Event Message Support Configurable Parameters Accepts Client Monitor and Control Messages Supports all Edition 2 Causes of Transmission Monitor Points: Control Points: M_SP_NA C_SC_NA M_DP_NA C_DC_NA M_ST_NA C_BO_NA M_BO_NA C_RC_NA M_ME_NA, NB, NC C_SE_NA, NB, NC M_IT_NA 1000 Points for all Supported Data Types, except 4000 total data words, maximum 500 commands maximum for all four clients Timestamp events are transferred to the other protocol through the mailbox feature. t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.

33 Hardware s Power Supply 24 Vdc nominal 18 Vdc to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 500 ma 32 Vdc maximum Operating Temperature -4 F to 122 F (-20 C to 50 C) Storage Temperature Relative Humidity Dimensions (Height x Width x Depth) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) -40 F to 185 F (-40 C to 85 C) 5% to 95% RH with no condensation Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols. Serial Port Isolation 2500 Vrms port signal isolation per UL Vdc min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5 mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only) Agency Approvals and Certifications CB Safety ATEX <Ex> II 3 G Ex na IIC T4 X -20 C <= Ta <= 50 C CE culus For Label & User Manual: <culus> E Class I Div 2 Groups A,B,C,D T6-30 C <= Ta <= 60 C Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: EtherNet/IP to IEC Client Gateway 5201-DFNT-104C To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com fax to Europe / Middle East / Africa europe@prosoft-technology.com fax to +33 (0) E Copyright 2011 ProSoft Technology, Inc., all rights reserved. 5/25/2011 s subject to change without notice.

34 DATASHEET Modbus TCP/IP to PROFIBUS DPV1 Master SE Gateway 5204SE-MNET-PDPMV1 Automating integration for Schneider Electric Modicon processors and maximizing ease-of-use are the hallmark design criteria behind the new ProLinx SE line of communication gateways. The first SE gateway, the 5204SE-MNET-PDPMV1 Modbus TCP/IP to PROFIBUS DP-V1 Master gateway, easily turns a Modicon M340 or Quantum Programmable Automation Controllers (PAC) into a PROFIBUS DP-V1 Master. The new Application Communication Logic functions built into ProSoft Configuration Builder (PCB) automatically generate all the Unity Pro data types, variables, and logic required for the M340 or Quantum to perform PROFIBUS DP-V1 cyclic and acyclic communication. PCB automatically generates customized export files based on the gateway's PROFIBUS DP network configuration. These files import into Unity Pro version 4 software without modification, eliminating the need to write additional communications message logic. Automatically-generated Derived Function Block logic also provides advanced PROFIBUS DP- V1 acyclic message pass-through capability. Acyclic messaging allows access to extended slave data and diagnostics, as well as access to slave-specific special functions. Whenever the PROFIBUS DP network configuration changes, new logic files can be automatically created, exported, and imported into an existing Unity Pro project, reducing engineering demands and cutting deployment time. Changes to the gateway's configuration can be password protected. Features Benefits New Application Communication Logic functions for use with Modicon M340 and Quantum PACs Designed specifically to enable a Modicon M340 or Quantum PAC using Modbus TCP/IP to act as a PROFIBUS DP-V1 Master Generates Unity Pro version 4.0 DFB logic and variable files from gateway configuration Automates the creation of application communication logic Ease-of-use means faster deployment, less engineering effort, fewer programming errors Acyclic Pass-Through Capability Automatically generated DFBs enable advanced PROFIBUS DP-V1 acyclic messaging with minimal engineering and programming effort Acyclic messaging allows a M340 or Quantum PAC to communicate directly with PROFIBUS DP slaves, to access special slave features, and to get extended slave diagnostics and process data Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration ProSoft Configuration Builder (PCB), with new Application Communication Logic functions, provides a PC-based software configuration solution for managing gateway configuration files, viewing communication status, and monitoring network diagnostics, as well as password-protected configuration downloads. The 5204SE-MNET-PDPMV1 User Manual provides step-by-step instructions on how to move data from one network to the other.

35 General s ProLinx Gateways ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. General s - SE Modbus TCP/IP Schematic The ProSoft Technology special SE Modicon Modbus TCP/IP implementation uses the gateway s shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and devices on other networks. This special version of the protocol, the first of its kind, has been developed to add PROFIBUS DP-V1 Master capability to Modicon PACs using their native Modbus TCP/IP communications capabilities and Unity Pro version 4.0 programming software. Modbus TCP/IP Server (Slave) The Modbus TCP/IP (MNET) server driver in the 5204SE-MNET-PDPMV1 is a special adaptation of the standard ProSoft Technology MNET driver, enhanced with Application Communication Logic functions for Unity Pro version 4. This special driver accepts incoming connections on Service Port 502 for Clients using Modbus TCP/IP MBAP messages and from Clients on Service Port 2000 (or other Service Ports) for Clients using Encapsulated Modbus messages. Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination of data types throughout the 4000-register memory database for read requests from remote Modbus TCP/IP Clients The special version of the MNET server accepts write requests from remote Modbus TCP/IP Clients only when those requests write to register memory database addresses in the range specified for PROFIBUS Output data to be sent to slave devices on the PROFIBUS DP network Supports five independent server connections for Service Port 502 (MBAP) Supports five independent server connections for Service Port 2000 (Encapsulated) Modbus data types overlap in the gateway s memory database, so the same data can be conveniently read or written as bit-level or register-level data Modbus TCP/IP Client (Master) Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats Offers one Client connection with up to 100 commands to talk to multiple servers Status Data Error codes, counters, and port status available through automatically-created Application Communication Logic DFBs and variables General s - PDPMV1 The module supports Master specifications according to IEC Cyclic I/O data and acyclic message parameter data can be transferred with PROFIBUS DP-V1 Class 1 or Class 2 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DP-V0 or DP-V1 protocol.

36 Functional s - Modbus TCP/IP Modbus Commands Supported (Client and Server) Configurable Parameters: (Client and Server) Configurable Parameters: Client Only Command List Status Data Command List Polling 1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers Gateway IP Address Modbus data type starting address offsets Floating point start address and database offset Minimum Command Delay Response Timeout Retry Count Command Error Pointer Up to 100 fully-configurable Client commands Error codes reported individually for each command Each command can be individually enabled or disabled; write-only-on-data-change is available Functional s - SE PROFIBUS DP-V1 Master Application Communication Logic functions in PCB automatically generate Unity Pro v4.0 DFB communication logic and variables for Modicon M340 and Quantum PAC systems from the PROFIBUS DP-V1 Master configuration Easy-to-use drag and drop Master Busview configuration interface via ProSoft Configuration Builder software Project-unique GSD file import library Automatic Bus Parameter calculation Online slave diagnostics through PCB Supports all standardized baud rates, up to 12 Mbps Supports extended diagnostic data (DP-V1 only) Auto baud detection at all valid PROFIBUS DP-V1 rates CRC checksum determination of slave to processor configuration consistency LED indicators for network Communication Status, Master Status, Token-Hold status, and Database (Configuration) Status FDT/DTM PROFIBUS DP Master transport communication DTM software included (see PSW-CDTM-PDPM) Up to 125 total slaves can be connected when using repeaters (up to 32 total nodes per network segment between repeaters) Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Up to 1536 cyclic bytes input and 1536 bytes output data Optically-isolated PROFIBUS DP interface with on-board DC-DC converter Modbus TCP/IP pass-through of acyclic read and write messages (DP-V1 only) Supports Sync and Freeze commands

37 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) Standard: 5.20 H x 2.07 W x 4.52 D inches (13.2 cm H x 5.25 cm W x 11.48cm D) Extended: 5.20 H x 2.73 W x 4.52 D inches (13.2 cm H x cm W x 11.48cm D) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking 10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adaptor Note: The number of serial application ports depends on the module type, and the combination of protocols. Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) Agency Approval & Certification For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: Modbus TCP/IP to PROFIBUS DPV1 Master SE Gateway 5204SE-MNET-PDPMV1 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com fax to Europe / Middle East / Africa europe@prosoft-technology.com fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. 12/22/2009 s subject to change without notice. UL/cUL ISA Class I, Div 2 Groups A, B, C, D cul C22.2 No. 213-M

38 'C' Programmable Application Development Module 5102-ADM4 The ProLinx 'C' Programmable Application Development Module provides a powerful platform for bridging communications between your custom serial protocols. This stand-alone DIN-rail mounted protocol gateway provides four fully programmable serial ports. 'C' Programmable Application Development Module 5102-ADM4 The ProLinx Application Development Modules are the ideal solution for developing custom communication between your serial protocol networks and devices. Using the provided API, the module can be used as a bridge, a port splitter, or any of several other useful applications. Each port is individually programmable. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English ADM The ADM API Suite allows software developers to access the serial ports without needing detailed knowledge of the module's hardware design. The ADM API Suite consists of two distinct components: the Serial Port API and the ADM API. Applications for the ADM module may be developed using industry-standard DOS programming tools and the appropriate API components. The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers. Development Environment Operating system: General software DOS 6-XL Compatible compiler (16-bit DOS target) o Digital Mars C++ V8.49 (included) o Borland C++ V5.02 Application Programming Interfaces (API) Serial Port API: serial port functions Backplane API: low level backplane functions ADM API debug port functions: debug port functions, database functions timer functions, high level backplane transfer functions, LED functions, flash read functions Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

39 General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-ADM4 'C' Programmable Application Development Module To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

40 'C' Programmable over Ethernet Gateway 5201/5202-ADMNET(4) The ProLinx Application Development Modules are the ideal solution for developing custom communication between your serial protocol networks and Ethernet devices. Using the provided API, the module can be used as a bridge, a port splitter, or any of several other useful applications. All application ports are individually programmable. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED 'C' Programmable over Ethernet Gateway 5201/5202-ADMNET(4) The ProLinx 'C' Programmable Gateway with Ethernet provides a powerful platform for bridging communications between your custom serial and Ethernet protocols. This stand-alone DIN-rail mounted protocol gateway provides either one or four fully programmable serial ports. The module provides one (ADMNET) or four (ADMNET4) serial ports, each individually configurable. ADMNET The ADM API Suite is provided to allow software developers access to the top layer of the serial ports. The ADMNET API suite accesses the Ethernet port. Both APIs can be easily used without having detailed knowledge of the module's hardware design. The ADMNET API Suite consists of the Ethernet Port API. The Ethernet Port API provides access to the Ethernet network. Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components. General Protocol s Allows software developers to access Serial/Ethernet ports without needing detailed knowledge of the module's hardware design API library functions are specified using the C programming language syntax Supports multi-threaded applications The following compiler versions are compatible with the MVI module API: o DigitalMars C++ V8.49 (included) o Borland C++ V5.02 Operating System General software DOS 6-XL Flash ROM program space: 896 KB RAM program and data space: 640 KB Compact Flash socket: Up to 64 MB ADM API Libraries Each API provides a library of function calls. This library supports any programming language that is compatible with the Pascal calling convention. Initialization Open and close the API Debug Port Debug port user interface Database Read and write data to database

41 Timer Start and check timers Backplane Transfer data over the backplane LED Set user LED indicators Flash Parse configuration files Miscellaneous Configure the console General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

42 'C' Programmable over Ethernet to Modbus Master/Slave Gateway 5201/5202-ADMNET(4)-MCM(4) The ADMNET-MCM module is the ideal solution for many applications where Ethernet and serial connectivity need to be added to a Modbus Master/Slave platform. Example applications involving the ADMNET-MCM module include: Bar code scanner interface Legacy ASCII protocol connections Terminal port emulation Printer driver (alarm/status printer) Customized protocol implementations How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 'C' Programmable over Ethernet to Modbus Master/Slave Gateway 5201/5202-ADMNET(4)-MCM(4) The ProLinx 'C' Programmable Application Development Module with Ethernet to Modbus Master/Slave creates a powerful platform for developing and running 'C' applications to communicate with Modbus Master/Slave networks and devices. The module provides one (ADMNET-MCM) or four (ADMNET4-MCM4) serial ports, each individually configurable as a Modbus or custom Master or Slave. ADMNET The ADM API Suite is provided to allow software developers access to the top layer of the serial ports. The ADMNET API suite accesses the Ethernet port. Both APIs can be easily used without having detailed knowledge of the module's hardware design. The ADMNET API Suite consists of the Ethernet Port API. The Ethernet Port API provides access to the Ethernet network. Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components. General Protocol s Allows software developers to access Serial/Ethernet ports without needing detailed knowledge of the module's hardware design API library functions are specified using the C programming language syntax Supports multi-threaded applications The following compiler versions are compatible with the MVI module API: o DigitalMars C++ V8.49 (included) o Borland C++ V5.02 Operating System General software DOS 6-XL Flash ROM program space: 896 KB RAM program and data space: 640 KB Compact Flash socket: Up to 64 MB ADM API Libraries Each API provides a library of function calls. This library supports any programming language that is compatible with the Pascal calling convention. Initialization Open and close the API Debug Port Debug port user interface Database Read and write data to database Timer Start and check timers Backplane Transfer data over the backplane LED Set user LED indicators Flash Parse configuration files Miscellaneous Configure the console

43 Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication parameters Error Checking Floating Point Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating point data movement supported, including configurable support for Enron implementation 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-ADMNET-MCM 5202-ADMNET4-MCM4 'C' Programmable over Ethernet to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

44 The ProLinx 'C' Programmable Application Development Module with Ethernet to Modbus TCP/IP creates a powerful platform for developing and running 'C' applications to communicate with Modbus TCP/IP networks and devices. The gateway provides one Ethernet port. The ADMNET functionality allows the module to be programmed to accommodate devices with unique Ethernet protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with realtime multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers. The Modbus TCP/IP protocol driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP for communicating over Ethernet networks. The gateway offers both Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections. The driver recognizes both Modbus TCP/IP MBAP and Encapsulated Modbus messages. DISCONTINUED 'C' Programmable over Ethernet to Modbus TCP/IP Gateway 5201-ADMNET-MNET Features Powerful network integration Benefits Communicate between dissimilar networks Shared database exchanges information from devices on both networks View diagnostics between both networks 'C' Programmable over Ethernet Develop and deploy 'C' applications for acustomimplementation, or to protect a proprietary algorithm Interface Modbus TCP/IP devices to Ethernet devices such as bar code scanners, alarm/status printers, terminal port emulation, and legacy protocols Rapidly create specialized applications using a familiar programming language Modbus TCP/IP protocol interface Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols Suitable for SCADA and "foreign device" interface applications Floating point data movement supported, including configurable support for Enron and Daniel floating point applications Communicate with programmable controllers, intelligent devices, sensors and instruments Allows PCs and HMIs to monitor field devices Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration The 'C' Programmable modules are completely configurable. The included API offers the option of text or binary configuration files, configuration through ladder logic, or hardcoded configuration within the application.

45 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. 'C' Programmable over Ethernet The ADMNET API is one component of the ProLinx ADM API Suite. The ADMNET API provides a simple module-level interface that is portable between members of the ProLinx Family. This is useful when developing an application that implements an Ethernet protocol for a particular device, such as a scale or bar code reader. After an application has been developed, it can be used on any of the ProLinx family modules. Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components. Development Environment Operating system: General software DOS 6-XL Compatible compiler (16-bit DOS target) o Digital Mars C++ V8.49 (included) o Borland C++ V5.02 Schematic SDK Includes ADM API LIB (library) File ADM API Header File Complete API Documentation Image file creation utility Image file download utility DigitalMars 'C' compiler General software DOS 6-XL Example Code Files Modbus TCP/IP ProSoft s Modbus TCP/IP implementation uses the gateway s shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks. Configurable floating point data movement is supported, including support for Enron or Daniel floating point applications. Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages.. Supports five independent server connections for Service Port 502 (MBP) Supports five independent server connections for Service Port 2000 (Encapsulated) Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination of data types throughout the memory database Modbus data types overlap in the gateway s memory database, so the same data can be conveniently read or written as bit-level or register-level data. Modbus TCP/IP Client (Master) Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats Offers one client connection with up to 100 commands to talk to multiple severs Status Data Error codes, counters, and port status available

46 Functional s 'C' Programmable over Ethernet Each API provides a library of function calls. This library supports any programming language that is compatible with the 'C' calling convention. Initialization Open and close the API Debug Port Debug port user interface Database Read and write data to database Timer LED Flash Modbus TCP/IP Modbus Commands Supported (Client and Server) Start and check timers Set user LED indicators Parse configuration files 1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple 5: Force (Write) Single Coil Holding Registers Configurable Gateway IP Address Parameters: Modbus data type starting address offsets (Client and Server) Floating point start address and database offset Configurable Minimum Command Delay Parameters: Response Timeout Client Only Retry Count Command Error Pointer Command List Up to 100 fully-configurable Client commands Status Data Error codes reported individually for each command Command List Polling Each command can be individually enabled or disabled; write-only-on-data-change is available Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Shipped with Each Unit 24 VDC nominal, 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status, Application Status DB-9M RS-232 only No hardware handshaking 10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) Agency Approval & Certification UL/cUL ISA Class I, Div 2 Groups A, B, C, D cul C22.2 No. 213-M1987 Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013 s subject to change without notice

47 AppSrvCE Application Development Module 7000-ADM The ProLinx 7000 series AppSrvCE Application Development Module is a highly flexible product that delivers programmability, communication protocols, and a powerful embedded historian. The module functionality is fully customizable and programmable using the EZ Design Studio software. Additionally, real-time data can easily be stored on the device using the integrated data historian. The AppSrvCE is the ideal solution for applications requiring custom 'C' programming, emissions monitoring and pharmaceutical manufacturing, or remote applications like utility RTUs, compressor monitoring and facilities monitoring. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English AppSrvCE Application Development Module 7000-ADM Historian The AppSrvCE uses licensed software technology from OSIsoft to deliver an integrated data historian. The AppSrvCE can log real-time data at sub-second speed accessible using OSIsoft's PI product. Additionally, data can be accessed via an OPC HDA server. This historical data is ideal for sequence-of-event recording, process optimization and compliance reporting (FDA, EPA, etc.) Features AppSrvCE is available with the following standard features. Additional and modified features are available. Supports all five IEC programming languages: Relay Ladder Logic, Sequential Function Chart, Function Block Diagram, Structured Text, and Instruction List 'C' for integration of custom code Drag-and-drop/menu driven editors enable rapid program development, reduce typing and syntax errors Object libraries make code reuse simple and efficient Easy debugging - Simulates code execution on the development station On-line monitoring with code selecting and real-time variable update Watch, Force I/O values and memory tags Supports complex data structures: o Three dimensional arrays o User defined structures Configuration tools for I/O drivers and communication protocols are managed from within EZ Design Studio. The multi-tasking execution engine allows for multiple tasks and priority levels including: o Cyclic tasks o Continuous task, background priority o I/O Sync task, execution sync. with I/O scan o o Fault task, runs when a fault condition occurs Start-up task, runs once prior to setting outputs to initialize machine state AppSrvCE is an industrial platform with no rotating media Standard TCP/IP networking between the node and workstation enables:

48 o o o o Remote program downloading Remote monitoring Remote node Start/Stop Multi-node management Module Features Operating Microsoft Windows CE.NET. System Processor 300 MHz x 86 processor Storage 32 Mbytes "Disk-on-a-Chip" SDRAM 32 to 256 Mbytes SRAM Battery-backed (512 Kbytes) Timers (3) general purpose 16-bit, (1) Watchdog timer IDE Interface Type I/II compact flash socket. Supports compact flash. IBM micro-drive, rotating media. Only Industrial Grade Compact Flash should be used. Clock Battery-powered, real time Software EZ Design Studio automation software for IEC programming Protection DataSafe enabled, restores realtime data after a power failure Status LEDs (9), 4 user defined, 5 system status Standard PC Connections USB Two USB 1.1 host interface ports. 1.5 and 12 Mbps. data rates Ethernet Two Ethernet ports, both are 10/100 Base-T. IEEE compliant, Category 5, RJ45 connectors Serial Communication Video Protocols 1- RS-232 port standard Add up to 5 additional RS-232, RS-422, RS- 485 ports Standard 15-pin VGA connector up to 1280x1024 (24-bit) display resolution Serial and Ethernet protocols include Generic Serial, EtherNet/IP, Modbus RTU, Modbus ASCII and Modbus TCP/IP. Other protocols are available upon request I/O Compatibility Rockwell Rockwell Automation 1769 Compact I/O Automation Rockwell Automation 1794 Flex or 1795 Integra I/O Custom Application Modules (CAMs) Embedded Base model ships with a blank CAM. Other CAMs available at request. High-performance I/O (optional) Hardware s Temperature Operating: 20 to 60 C Storage: -40 to 85 C Mounting DIN-rail or panel mounting Humidity 5% to 95% non-condensing Vibration 10 to 500 Hz 2.0 G max. peak acceleration in (peak-to-peak) displacement Shock Operating: 30 G peak for 11ms Storage: 50 G peak for 11ms Weight 1.7 lbs. ( g) Power 10 to A 27 VDC max. User supplied. Battery Lithium. Maintains a 30 day charge Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 7000-ADM AppSrvCE Application Development Module To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. February 27, 2008

49 ASCII Generic Serial to PROFIBUS DP Slave Gateway ASCII Generic Serial to PROFIBUS DP Slave Gateway 5105-ASCII-PDPS The ASCII-PDPS modules are the ideal solution for the many applications where PROFIBUS DP Slave connectivity can be used to integrate an ASCII generic serial input device into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to a PROFIBUS master device. In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5105-ASCII-PDPS The ProLinx ASCII Generic Serial to PROFIBUS DP Slave Gateway creates a powerful connection between a PROFIBUS DP master device and an ASCII input device. The module provides one PROFIBUS DP Slave port and one ASCII configurable serial port. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory

50 allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site PROFIBUS s Communication Baud Rate: 9.6 kbit/s 12 Mbit/s parameters Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total Supported PROFIBUS DP features Configurable Parameters PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5105-ASCII-PDPS ASCII Generic Serial to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

51 DATASHEET BACnet/IP Client to PROFIBUS DP-V0 Slave Gateway 5205-BACNET-PDPS The ProLinx BACnet/IP Client to PROFIBUS DP-V0 Slave gateway creates a powerful connection between a PROFIBUS Master and BACnet/IP server devices. This stand-alone, DIN-rail-mounted, dual-protocol gateway provides a PROFIBUS Slave port and a BACnet/IP Client Ethernet port. The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished, using the provided ProSoft Configuration Builder software. The ProLinx BACnet/IP (Building Automation and Control networking) protocol implementation is designed specifically to meet the communication needs of building automation and control systems by providing limited BACnet/IP command support for such applications as heating, ventilating, and airconditioning control, lighting control, access control, and fire detection systems. Features Benefits Powerful network integration Move data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port BACnet/IP Client Standard protocol for Building Automation and Control limited to Analog and Digital I/O commands Communicate with Building Automation controllers, HVAC, Fire and Safety equipment Support for Trane Building Control Unit (BCU) PROFIBUS DP-V0 Slave Adds BACnet/IP device monitoring and control to a PROFIBUS DP network Easy configuration - GSD file provided 122 words input/122 words output, 200 words maximum I/O Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.

52 General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Ethernet Configuration Port serves as a dual BACnet/IP Client application port DIN to DB-9M serial port cable included per configurable serial port BACnet/IP Client The BACnet driver supports a single UDP client to interface with one or more devices that contain a BACnet/IP server The ProLinx BACnet/IP driver implements a limited subset of the BACnet/IP protocol primarily used with the Trane BCU The module controls the read/write data transfer between the gateway and other BACnet/IP devices PROFIBUS DP to BACnetIP PROFIBUS DP-V0 Slave Input and Output data blocks are mapped by the user within the ProLinx module s data memory allowing the user maximum flexibility and data transfer with other protocols. A standard PRLX05A5.GSD file is provided on the Product CD Baud rate communication parameters: 9.6 kbps to 12 Mbps Status Data Error codes available on an individual command basis Functional s BACnet/IP Client The BACnet/IP Client can be used to interface many different protocols with Ethernetenabled BACnet devices. The ProLinx BACnet/IP driver implements a limited subset of the BACnet/IP protocol. Contact ProSoft Technology Technical Support if you have any protocol compliance or functionality questions. General Command List One client Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Service Port 1 to Function Code (limited) 12=Read Single Property 14=Read Multiple Properties 15=Write Single Property 16=Write Multiple Property Data Type (limited) 0=Analog Input 1=Analog Output 3=Binary Input 4=Binary Output Point Count 1 to 25 PROFIBUS DP-V0 Slave Slave configurable parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Failsafe Action Communication Failure Mode Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS DP-V0 Support Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Read/Write Mailbox Commands Commands allowing 1800 extended I/O data bytes

53 Hardware s Power Supply Current Load Operating Temperature Storage Temperature 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma 32 VDC max -4 F to 122 F (-20 C to 50 C) -40 F to 185 F (-40 C to 85 C) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Relative Humidity Dimensions (Height x Width x Depth) LED Indicators BACnet/IP and Configuration Ethernet Port 5% to 95% (without condensation) Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status 10 Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration PROFIBUS Slave Port RS485, max. 12 MBit/s, isolated, EN Shipped with Each Unit Mini-DIN8-to-DB9M Adapter cable 6 ft RS232 null-modem configuration cable CD (docs and Configuration utility) Agency Approvals & Certifications UL/cUL ISA Class I, Div 2 Groups A, B, C, D cul C22.2 No. 213-M1987 For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: BACnet/IP Client to PROFIBUS DP-V0 Slave Gateway 5205-BACNET-PDPS To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com fax to Europe / Middle East / Africa europe@prosoft-technology.com fax to +33 (0) Copyright 2010 ProSoft Technology, Inc., all rights reserved. 3/16/2010 s subject to change without notice

54 DF1 Master/Slave to IEC Slave Gateway 5102-DFCM3-101S The DFCM-101S modules are the ideal solution for the many applications where IEC Slave connectivity can be used to integrate DF1 Master/Slave devices into a system. The 101 gateway is a powerful module designed with Slave support, enabling easy connection to an IEC Master device. In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DF1 Master/Slave to IEC Slave Gateway 5102-DFCM3-101S The ProLinx DF1 Master/Slave to IEC Slave Gateway creates a powerful connection between devices on an IEC 101 network and DF1 devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one IEC 101 Slave configurable serial port and three DF1 Master or Slave configurable serial ports. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking Miscellaneous BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

55 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DFCM3-101S DF1 Master/Slave to IEC Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

56 DF1 Master/Slave to IEC Master Gateway 5102-DFCM-103M The ProLinx DF1 Master/Slave to IEC Master Gateway creates a powerful connection between devices on a DF1 network and IEC 103 slave devices. This stand-alone DIN-rail mounted protocol gateway provides two configurable serial ports. DF1 Master/Slave to IEC Master Gateway 5102-DFCM-103M The DFCM-103M modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate IEC devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC device support, the module provides a very powerful interface to the many IEC devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

57 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DFCM-103M DF1 Master/Slave to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

58 DF1 Master/Slave to ASCII Generic Serial Gateway 5102-DFCM-ASCII3 The ProLinx DF1 to ASCII Generic Serial Gateway creates a powerful connection between devices on a DF1 network and ASCII devices. This stand-alone DIN-rail mounted protocol gateway provides one DF1 configurable serial port and three ASCII configurable serial ports. DF1 Master/Slave to ASCII Generic Serial Gateway 5102-DFCM-ASCII3 The DFCM-ASCII modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate ASCII serial input devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

59 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DFCM-ASCII3 DF1 Master/Slave to ASCII Generic Serial Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

60 DF1 Master/Slave to Honeywell DE Master Gateway 5106-DFCM-DEM The DFCM-DEM modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate Honeywell DE devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE device support, the module provides a very powerful interface to the many Honeywell DE devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DF1 Master/Slave to Honeywell DE Master Gateway 5106/5126-DFCM-DEM(2) The ProLinx DF1 Master/Slave to Honeywell DE Master Gateway creates a powerful connection between devices on a DF1 network and Honeywell DE devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and eight Honeywell DE channels. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking Miscellaneous BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

61 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module. DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source LEDs for Visual Module Status External 24 VDC source connection on the front of the DEM module provides instrument loop power DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5106-DFCM-DEM DF1 Master/Slave to Honeywell DE Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

62 DF1 Master/Slave to HART Multi-drop Gateway 5107/5127-DFCM-HART(2) The DFCM-HART modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate HART devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Hart device support, the module provides a very powerful interface to the many HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED DF1 Master/Slave to HART Multi-drop Gateway 5107/5127-DFCM-HART(2) The ProLinx DF1 Master/Slave to HART Multi-drop Gateway creates a powerful connection between devices on a DF1 network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and up to eight HART channels. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fullyconfigurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Full Duplex Slave (not peer mode) Half Duplex Polled Configurable Data Table File Start (File N[x] 0 to 999) parameters per slave Data Table File Size (1 to 1000 words) port Data Table location in database (0 to 3999)

63 HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Configurable Parameters per Channel HART Driver Command List Polling of command list Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 0 to 50 C (32 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013

64 DISCONTINUED DF1 Master/Slave to HART Analog Gateway 5108-DFCM-HART / 5128-DFCM-HART DF1 Master/Slave to HART Analog Gateway 5108-DFCM-HART / 5128-DFCM-HART The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a DF1 network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to milliseconds BCC and CRC Full hardware handshaking control, providing radio, smart modem and multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex - Master (Module generates commands) Half-Duplex - Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

65 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex - Slave (not peer mode) Half Duplex - Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) HART Analog The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Configurable Parameters per Channel HART Driver Command List Polling of command list Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. Isolated HART Analog Input s Input Range Current: 4 to 20mA with HART Resolution 16bits Input Filter First Order Sync: 10 Hz Current Input Resistance ohms +/- 1% Isolated HART Analog Input s Open circuit detection 1/2 second maximum time Over current +/-40mA continuous, maximum Common Mode Noise Rejection Calibrated 25 C 105dB 4 to 20 ma: 0.05% of reading Input Isolation Voltage 2500 V RMS per UL 1577, transformer isolated 24V DC Isolation Voltage 1500 VDC HART is a registered trademark of the HART Communication Foundation Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Input 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 1-4 ch: 190 ma max@ 32 VDC max 5-8 ch: 250 ma max@ 32 VDC max Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status HART Channel Activity (Green)

66 Configuration Serial DB-9M RS-232 only Port No hardware handshaking HART Interface Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs) Screw terminals for each channel Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Common Mode Rejection Over current Overvoltage Protection DC +/- 40mA continuous, maximum All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection s are subject to change without notice. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013 Accuracy 4 to 20 ma: 0.05% of 25 C 24VDC loop output power Shipped with Each Unit Certifications 1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS- 422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector CE and ATEX Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Compatible products in this product line also include: EtherNet/IP to HART Analog Gateway (5208-DFNT-HART / 5228-DFNT-HART) Modbus TCP/IP to HART Analog Gateway (5208-MNET-HART / 5228-MNET-HART) Visit our web site at for a complete list of products.

67 DF1 Master/Slave to PROFIBUS DP Master Gateway 5104-DFCM-PDPM The ProLinx DF1 Master Slave to PROFIBUS DP Master Gateway creates a powerful connection between devices on a DF1 network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and PROFIBUS DP Master port. DF1 Master/Slave to PROFIBUS DP Master Gateway 5104-DFCM-PDPM The DFCM-PDPM modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus Master/Slave gateway is a powerful module designed with Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi- Master network. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

68 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5104-DFCM-PDPM DF1 Master/Slave to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

69 DF1 Master/Slave to PROFIBUS DP Slave Gateway 5105-DFCM-PDPS The DFCM-PDPS modules are the ideal solution for the many applications where PROFIBUS connectivity can be used to integrate DF1 devices into a system. The PROFIBUS DP Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DF1 Master/Slave to PROFIBUS DP Slave Gateway 5105-DFCM-PDPS The ProLinx DF1 Master/Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a PROFIBUS DP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS DP Slave. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking Miscellaneous BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

70 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5105-DFCM-PDPS DF1 Master/Slave to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

71 EtherNet/IP to IEC Slave Gateway 5201-DFNT-101S The DFNT-101S modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate an IEC 101 master device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 101 Slave device support, the module provides a very powerful interface to the many IEC 101 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to IEC Slave Gateway 5201-DFNT-101S The ProLinx EtherNet/IP to IEC S Gateway creates a powerful connection between devices on an EtherNet/IP network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 101 Slave configurable serial port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).

72 IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 0 to 50 C (32 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-101S EtherNet/IP to IEC Slave Gateway Note: The 5201-DFNT-101S is in a Final Sales Period of two years, effective October 14, 2008 until October 14, Thereafter, the product will continue to be supported until October 14, The recommended replacement product is the 5102-DFCM3-101S DF1 Master/Slave to IEC 101 Slave Communication Gateway. For more information on the Product Retirement Program, please visit: To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

73 EtherNet/IP to IEC Master Gateway 5201-DFNT-103M The DFNT-103M modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate an IEC 103 slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to IEC Master Gateway 5201-DFNT-103M The ProLinx EtherNet/IP to IEC Master Gateway creates a powerful connection between devices on an EtherNet/IP network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

74 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-103M EtherNet/IP to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

75 EtherNet/IP to IEC Server Gateway 5201-DFNT-104S The DFNT-104S modules are the ideal solution for joining EtherNet/IP and IEC Server networks. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 104 Server device support, the module provides a very powerful interface to the many IEC 104 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to IEC Server Gateway 5201-DFNT-104S The ProLinx EtherNet/IP to IEC Server Gateway creates a powerful connection between an EtherNet/IP network and IEC 104 client devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

76 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-104S EtherNet/IP to IEC Server Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

77 EtherNet/IP to ASCII Generic Serial Gateway 5201/5202-DFNT-ASCII(4) The DFNT-ASCII modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate ASCII serial devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to ASCII Generic Serial Gateway 5201/5202-DFNT-ASCII(4) The ProLinx EtherNet/IP to ASCII Generic Serial Gateway creates a powerful connection between devices on an EtherNet/IP network and ASCII devices. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port and up to four ASCII configurable serial ports. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

78 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-ASCII 5202-DFNT-ASCII4 EtherNet/IP to ASCII Generic Serial Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

79 EtherNet/IP to BOSCH Packaging Machinery Gateway 5201/5202-DFNT-BSCH(4) The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). The BOSCH Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the BOSCH protocol (Master, Error Checking, Baud rate, etc). How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , Languages spoken include: French, English North America , Languages spoken include: English, Spanish Latin America (Sales only) , Languages spoken include: Spanish, English Brasil , Languages spoken include: Portuguese, English EtherNet/IP to BOSCH Packaging Machinery Gateway 5201/5202-DFNT-BSCH(4) The ProLinx EtherNet/IP to BOSCH Packaging Machinery Gateway creates a powerful connection between devices on an EtherNet/IP network and BOSCH packaging machinery. The module provides a single Ethernet port and up to four BOSCH configurable serial ports. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The BOSCH Master protocol driver supports Master implementations of the protocol on up to four ports. Each of the ports is individually configurable. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

80 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). BOSCH Packaging Machinery The BOSCH Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the BOSCH protocol (Master, Error Checking, Baud rate, etc). General Parameters Type Internal Database BOSCH Modes Error Checking BOSCH Master Driver Type General Configurable Parameters per Master port BOSCH Commands supported Command List Status Data Polling of command list s 4000 registers (words) available Full-Duplex BCC s Full-Duplex, Point to Point Min Command Delay, Number of Commands, Response Timeout, Retry Count, Slave List Error Pointer 0x00 Protected Write 0x01 Unprotected Read Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port. User configurable polling of commands, including disabled, continuous and on change of data (write only) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-BSCH 5202-DFNT-BSCH4 EtherNet/IP to BOSCH Packaging Machinery Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

81 DATASHEET EtherNet/IP to CC-Link Local & Intelligent Station Gateway 5209-DFNT-CCLINK ProSoft Technology's EtherNet/IP to CC-Link communication gateway allows Rockwell Automation control platform users to integrate CC-Link Master compatible products with existing EtherNet/IP control networks. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol and is user-configurable as both a Client and/or a Server. As a Client, the gateway can send commands and manage data flow among a large number of devices on the EtherNet/IP network. As a Server, the gateway can provide concurrent data transfer to multiple Clients. The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network. Features Benefits Powerful network integration Communicate between dissimilar networks A shared, 10,000-word database exchanges information from devices on both networks Allows integration of EtherNet/IP-based systems onto a CC-Link Master-controlled network EtherNet/IP Client/Server Explicit Messaging communication supported Allows up to five concurrent Server connections from multiple network Clients Provides three concurrent Client connections, supporting up to 100 commands per Client CC-Link Intelligent or Local Station Compatible with CC-Link Version 1.10 Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station As a Local Station, provides a read-only list of all network slaves cyclic and status data CC-Link Partner Association (CLPA) Certification Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.

82 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools used by different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol has been implemented to provide asynchronous data transfer between the ProLinx gateway and Rockwell Automation hardware. Supported PLC Types PLC-2, PLC-3, PLC-5, SLC 500, ControlLogix, CompactLogix, and MicroLogix Messaging Types As a Client, PCCC Explicit Messaging As a Server, PCCC or CIP Explicit Messaging Command Sets PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500 Command Set Schematic CC-Link CC-Link (Control & Communication Link) is an open-standard-based communication protocol that enables easy connection to Mitsubishi and other Master PLCs. CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide. The ProLinx CC-Link interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer. The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector. Functional s EtherNet/IP Server In Server mode, the gateway accepts messages from one or more Clients that want to read data from or write data to the gateway's internal memory database. Miscellaneous EtherNet/IP Server PCCC Data File Emulation (the Server looks like an SLC 5/05 to the Clients) CIP Services Supported Binary, Integer or Floating point data supported, as well as other special data types, like timers, counters, ASCII files and more Five independent TCP/IP Server sockets permit multiple Clients to see and change all user data contained in the gateway. The Server supports CIP and PCCC Explicit Message connections from EtherNet/IP Clients. Data Table File Size: 100 or 1000 words Data Table File Start: - Fixed at N10 Data Table Range: N10 to N109, based on file size set to 100, or N10 to N19, based on file set to 1000 (Other data table types also supported) 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write

83 EtherNet/IP Client In Client mode, the gateway controls read and write data transfers between the itself and other EtherNet/IP devices. Data transfer can be initiated and executed with no logic programming required in the target Rockwell Automation hardware. EtherNet/IP Client Command List Command Poll List Configurable Parameters CC-Link Three simultaneous Client connections Each Client supports up to 100 read or write commands per Client, allowing up to three concurrent connections with Ethernet/IP devices. User can enable or disable polling on a percommand basis, as well as choose to write continuously or only on change of data. Number of commands (Up to 100 per client) Min Command Delay Response Timeout Retry Count (and much more) CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing it's I/O data transfer capacity. Maximum Number of Occupied Stations Maximum Number of Devices per Network Device Types Supported CC-Link Version supported Message handling Cyclic Data Capacity Additional I/O Data Transfer Capacity Transient Message Commands 4 stations, consecutive addresses Devices depending on Local and Slave Stations configured Intelligent Device and Local Station CC-Link Version 1.10 cyclic data transmission Cyclic Messages and Transient Messages 24 input data words and 24 output data words. Up to 4 slave stations supporting 4 words/32 bits per slave Transient Messaging extends I/O data transfer capacity by more than 8,000 additional words System Information, Memory Access Information, RUN, STOP, Line Test, Memory Read, and Memory Write commands Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Communication speed Transmission path format Transmission format Error control system 10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps Bus format (EIA RS485 conformance) HDLC conformance CRC (X16+X12+X5+1) Conformance Testing Conformance testing through the CC-Link partner Association (CLPA) ensures that the gateway meets the performance specifications required to become CC-Link certified.

84 Hardware s Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, and Ground terminals 2.5 mm screwdriver blade-sized terminals Current Load 500 ma max@ 32 VDC max Operating Temperature -20 to 50 C (-4 to 122 F) Storage Temperature -40 to 85 C (-40 to 185 F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) General LED Indicators Power and General Status Application Status Serial Port Activity LED Serial Activity and Error LED Status CC-Link LED Indicators Run (Network Status) L Run (Data Link Execution) L Err (Data Link Comm Error) SD (Sending Data LED) RD (Receiving Data LED) ERR (Switch Setting Error) Configuration Serial Port DB-9M RS-232 only No hardware handshaking Ethernet Port RJ45 Connector, 10Mbit, half-duplex only Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration CC-Link Interface Pin DA Data Communication line A DB Data Communication line B DG Digital Ground SLD Shield FG Frame Ground Shipped with Each Unit Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) CC-Link to Terminal Block connector Agency Approval & Certification ISA CC-Link Partner Association Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following. If you are unsure which product to select, please contact your local distributor. EtherNet/IP to CC-Link Local Station & Intelligent Device Gateway 5209-DFNT-CCLINK To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. 11/7/2013 s subject to change without notice.

85 EtherNet/IP to Command Language Master Gateway 5201/5202-DFNT-CLVM(4) The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). The CLV Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the CLV protocol (Master, Error Checking, Baud rate, etc). How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , Languages spoken include: French, English North America , Languages spoken include: English, Spanish Latin America (Sales only) , Languages spoken include: Spanish, English Brasil , Languages spoken include: Portuguese, English EtherNet/IP to Command Language Master Gateway 5201/5202-DFNT-CLVM(4) The ProLinx EtherNet/IP to Command Language Master Gateway creates a powerful connection between devices on an EtherNet/IP network and SICK barcode scanners. The module provides a single Ethernet port and up to four CLV Master configurable serial ports. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

86 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). CLV Master The CLV Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the CLV protocol (Master, Error Checking, Baud rate, etc). General s Ports Receive buffer size Receive termination Receive database location 1 to 3896 Communication Configuration One to four ports to receive and/or transmit data 255 bytes Termination character Baud Rates 110 to 115,200 Parity None, Odd, Even Data Bits 5 to 8 Stop Bits 1 or 2 RTS On and Off Timing 0 to milliseconds Minimum Response Delay 0 to milliseconds Hardware Handshaking RTS/CTS Supports device type of CLV 41X, V1.10 H757 to V1.30 I415 General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-CLVM 5202-DFNT-CLVM4 EtherNet/IP to Command Language Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

87 DISCONTINUED EtherNet/IP to Honeywell DE Master Gateway EtherNet/IP to Honeywell DE Master Gateway 5206-DFNT-DEM The DFNT-DEM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate Honeywell DE slave devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE Master support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5206-DFNT-DEM The ProLinx EtherNet/IP to Honeywell DE Master Gateway creates a powerful connection between devices on an EtherNet/IP network and Honeywell DE slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and eight Honeywell DE Master channels. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.

88 EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module. DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source LEDs for Visual Module Status External 24 VDC source connection on the front of the DEM module provides instrument loop power DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

89 EtherNet/IP to DF1 Master/Slave Gateway 5201/5202-DFNT-DFCM(4) The DFNT-DFCM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate DF1 devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 Master/Slave device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to DF1 Master/Slave Gateway 5201/5202-DFNT-DFCM(4) The ProLinx EtherNet/IP to DF1 Master/Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Polling of command list Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. User configurable polling of commands, including disabled, continuous and on change of data (write only).

90 DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-DFCM EtherNet/IP to DF1 Master/Slave Gateway 5202-DFNT-DFCM4 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

91 EtherNet/IP to DH-485 Gateway 5201-DFNT-DH485 The DH485-DFNT modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a DH-485 device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to DH-485 Gateway 5201-DFNT-DH485 The ProLinx EtherNet/IP to DH-485 Gateway creates a powerful connection between devices on EtherNet/IP and DH-485 networks. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one DH-485 configurable serial port. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

92 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-DH485 EtherNet/IP to DH-485 Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

93 EtherNet/IP to DNP 3.0 Master Gateway 5201-DFNT-DNPM The DFNT-DNPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate DNP 3.0 Master serial devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP Master device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to DNP 3.0 Master Gateway 5201-DFNT-DNPM The ProLinx EtherNet/IP to DNP 3.0 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and DNP Slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

94 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation DNP Master Node address Slave count Command count 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-DNPM EtherNet/IP to DNP 3.0 Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

95 EtherNet/IP to DNP 3.0 Slave Gateway 5201-DFNT-DNPS The ProLinx EtherNet/IP to DNP 3.0 Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and DNP master devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port. EtherNet/IP to DNP 3.0 Slave Gateway 5201-DFNT-DNPS The DFNT-DNPS modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate DNP 3.0 Slave devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

96 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-DNPS EtherNet/IP to DNP 3.0 Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

97 EtherNet/IP to DNP 3.0 over Ethernet Gateway EtherNet/IP to DNP 3.0 over Ethernet Gateway 5201-DFNT-DNPSNET The DFNT-DNPSNET modules are the ideal solution for joining EtherNet/IP and DNP over Ethernet networks. This Ethernet to Ethernet gateway is a powerful module designed with both Client and Server support for each protocol, enabling easy connections between the dissimilar network types. The module utilizes a shared database so that the two protocols can quickly and easily transfer data between themselves. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201-DFNT-DNPSNET The ProLinx EtherNet/IP to DNP over Ethernet Gateway creates a powerful connection between devices on EtherNet/IP and DNP over Ethernet networks. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.

98 EtherNet/IP Client s General Command List Polling of command list One client Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. User configurable polling of commands, including disabled, continuous and on change of data (write only). DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-DNPSNET EtherNet/IP to DNP 3.0 over Ethernet Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to

99 Europe fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

100 EtherNet/IP to GE Ethernet Global Data Gateway 5201-DFNT-EGD The DFNT-EGD modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate GE Ethernet Global Data devices into a system. The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported). In combination with the GE Ethernet Global Data device support, the module provides a very powerful interface to the many EtherNet/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosoft-technology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to GE Ethernet Global Data Gateway 5201-DFNT-EGD The ProLinx EtherNet/IP to GE Ethernet Global Data Gateway creates a powerful connection between EtherNet/IP and GE Ethernet Global Data networks. The module provides one Ethernet port. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common. This common database provides the "backbone" communications for various field devices using different networks EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start - Fixed at N10 Data Table File Size or 1000 words CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).

101 EGD GE Fanuc Automation and GE Drive Systems developed an Ethernet Global Data, or EGD, exchange for PLC and computer data in GE Ethernet Global Data (EGD) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Bandwidth utilization is optimized by using efficient communication methods. High reliability means fewer communication failures and having the ability to detect failures upon occurrence. Particular emphasis is delivered for applications requiring periodic or frequent updates and time synchronization of devices. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the network can produce these types of messages and each device determines which of these messages to consume. The module supports the following functions specified in the EGD protocol: Code 3 Retrieve Configuration Request (example provided) 4 Retrieve Configuration Response (example provided) 7 Summary Request 8 Summary Response 9 Capabilities Request 10 Capabilities Request 15 Statistics Request 16 Statistics Response 18 Command NAK 32 Read Request 33 Read Response 34 Write Request 35 Write Response 36 Masked Write Request 37 Masked Write Response General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-EGD EtherNet/IP to GE Ethernet Global Data Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. April 29, 2014

102 EtherNet/IP to Garvens Remote Control Checkweigher Gateway 5201/5202-DFNT-GRCM(4) The ProLinx EtherNet/IP to Garvens Remote Control Checkweigher Gateway creates a powerful connection between devices on an EtherNet/IP network and Garvens high speed checkweighers. The module provides a single Ethernet port and up to four configurable serial ports. EtherNet/IP to Garvens Remote Control Checkweigher Gateway 5201/5202-DFNT-GRCM(4) The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and Rockwell Automation hardware. (Implicit Messaging - connected I/O communications - is not supported). The GRCM driver permits the module to interface Garvens Checkweighers using Garvens Remote Control (GARECO) serial protocol with EtherNet/IP devices. The gateways provides one or four serial ports that allow connection of one to four GARECO serial devices, one per port. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

103 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). GARECO Protocol for Hi-Speed Checkweigher The GRCM driver permits the gateway to interface checkweighers using Garvens Remote Control serial protocol to Rockwell Automation EtherNet/IP devices over Ethernet. The 5201 has one GARECO serial port and the 5202 has four GARECO serial ports to provide communication access for one GARECO serial device per port. General s Ports One to four ports to receive and/or transmit data; One GARECO device allowed per port 255 bytes Termination character 0 to 7000 Receive Buffer Size Receive Termination Receive Database Location Supports device types of Topline VS/VO, "S" Series, and "E" Series General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 0 to 50 C (32 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-GRCM 5202-DFNT-GRCM4 EtherNet/IP to GARECO Protocol for Hi- Speed Checkweigher Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

104 EtherNet/IP to HART Multi-drop Gateway 5207-DFNT-HART The DFNT-HART modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate HART Multi-drop devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to HART Multi-drop Gateway 5207-DFNT-HART The ProLinx EtherNet/IP to HART Multi-drop gateways create a powerful connection between devices on an EtherNet/IP network and HART Multi-drop devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and four HART Multidrop channels. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File CIP Services Supported Data Table File Start - Fixed at N10 Data Table File Size or 1000 words 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).

105 HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Configurable Parameters per Channel HART Driver Command List Polling of command list Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status HART Channel Activity (Green) DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) HART Interface 24VDC power Shipped with Each Unit RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-persecond and less than or equal to 5 minutes duration Four (4) HART Multi-drop channels Screw terminals for each channel Screw terminal for 24VDC Provides HART loop power Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) HART Terminal Block connector ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5207-DFNT-HART EtherNet/IP to HART Multi-drop Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. February 08, 2008

106 DATASHEET EtherNet/IP to HART Analog Gateway 5208-DFNT-HART / 5228-DFNT-HART EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging Miscellaneous PCCC on CIP Explicit Messaging supported 125 word read and write data lengths Floating point data supported EtherNet/IP to HART Analog Gateway 5208-DFNT-HART / 5228-DFNT-HART The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on an EtherNet/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options. EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start - Fixed at N10 Data Table File Size or 1000 words CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.

107 EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). HART Analog The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Configurable Parameters per Channel HART Driver Command List Polling of command list Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. Isolated HART Analog Input s Input Range Current: 4 to 20mA with HART Resolution 16bits Input Filter First Order Sync: 10 Hz Current Input Resistance ohms +/- 1% Open circuit detection 1/2 second maximum time Over current Common Mode Noise Rejection +/-40mA continuous, maximum 105dB Isolated HART Analog Input s Calibrated 25 C 4 to 20 ma: 0.05% of reading Input Isolation Voltage 2500 V RMS per UL 1577, transformer isolated 24V DC Isolation Voltage 1500 VDC HART is a registered trademark of the HART Communication Foundation Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Input 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port HART Interface 1-4 ch: 190 ma max@ 32 VDC max 5-8 ch: 250 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status HART Channel Activity (Green) DB-9M RS-232 only No hardware handshaking Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs) Screw terminals for each channel

108 Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Common Mode DC Rejection Over current +/- 40mA continuous, maximum Overvoltage Protection All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection Accuracy 4 to 20 ma: 0.05% of 25 C 24VDC loop output power Shipped with Each Unit Certifications 1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector CE and ATEX Ordering Information To order this product, please use the following: 5208-DFNT-HART / EtherNet/IP to HART Analog Gateway 5228-DFNT-HART To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) s are subject to change without notice. Copyright ProSoft Technology, Inc All Rights Reserved. 11/7/13 Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Compatible products in this product line also include: Modbus TCP/IP to HART Analog Gateway (5208-MNET-HART / 5228-MNET-HART) DF1Master/Slave to HARTAnalog Gateway (5108-DFCM-HART / 5128-DFCM-HART) Visit our web site at for a complete list of products.

109 EtherNet/IP to Modbus Master/Slave Gateway 5201/5202-DFNT-MCM(4) The DFNT-MCM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate Modbus serial devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to Modbus Master/Slave Gateway 5201/5202-DFNT-MCM(4) The ProLinx EtherNet/IP to Modbus Master/Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

110 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DFNT-MCM 5202-DFNT-MCM4 EtherNet/IP to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

111 EtherNet/IP to PROFIBUS DP Master Gateway 5204-DFNT-PDPM The DFNT-PDPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to PROFIBUS DP Master Gateway 5204-DFNT-PDPM The ProLinx EtherNet/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB9F port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi- Master network. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

112 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5204-DFNT-PDPM EtherNet/IP to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

113 EtherNet/IP to PROFIBUS DPV1 Master Gateway 5204-DFNT-PDPMV1 The DFNT-PDPM modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , brasil@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to PROFIBUS DPV1 Master Gateway 5204-DFNT-PDPMV1 The ProLinx EtherNet/IP to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB9F port. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC on either a Mono-Master or Multi- Master network. The module supports the DPV1 specification. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start - Fixed at N10 Data Table File Size or 1000 words CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).

114 PROFIBUS DP Master V1 The module supports complete Master specifications according to IEC Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol. The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network. Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB) Project-unique GSD file import library Monitoring and Modification of process data and DPV1 acyclic data Multi-drop on a PROFIBUS DPV1 network drop with other compatible devices Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network Automatic project documentation Automatic Bus Parameter calculation Online slave diagnostics Supports all standardized baud rates, up to 12Mbps Supports extended diagnostic data (DPV1) Auto baud detection at all valid PROFIBUS DPV1 rates Multiple modules can be placed in a single rack CRC checksum determination of slave configuration consistency to processor Master Status LED Indicators for Operations, Network Drop Communication, Master Token-Hold FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM) PROFIBUS Master s Up to 125 Slaves can be connected with a repeater Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words) output data Supports Extended Diagnostic Data RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter Acyclic communications (DPV1), Read and Write Alarm Handling (DPV1) Supports Sync and Freeze commands Supports PROFIdrive 3.1 compliant parameter read and write operations Supports Multicast and Broadcast telegrams (DPV1) PROFIBUS Master Port DB-9F Optically Isolated RS-485 Ready, Run, Error and Token LED Indicators PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female connector and isolated Opto-Couplers General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max Operating Temperature -20 to 50 C (-4 to 122 F) Storage Temperature -40 to 85 C (-40 to 185 F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules RJ45 Connector only) Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5204-DFNT-PDPMV1 EtherNet/IP to PROFIBUS DPV1 Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. February 29, 2008

115 EtherNet/IP to PROFIBUS DP Slave Gateway 5205-DFNT-PDPS The DFNT-PDPS modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a PROFIBUS DP master device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to PROFIBUS DP Slave Gateway 5205-DFNT-PDPS The ProLinx EtherNet/IP to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an EtherNet/IP network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Slave configurable DB9F port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

116 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5205-DFNT-PDPS EtherNet/IP to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

117 EtherNet/IP to Rockwell Automation Remote I/O Gateway 5210-DFNT-RIO The DFNT-RIO modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a Remote I/O device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English EtherNet/IP to Rockwell Automation Remote I/O Gateway 5210-DFNT-RIO The ProLinx EtherNet/IP to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on an EtherNet/IP network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count.

118 EtherNet/IP Client s Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5210-DFNT-RIO EtherNet/IP to Rockwell Automation Remote I/O Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

119 DF1 Serial Port Expander Gateway DF1 Serial Port Expander Gateway 5102-DFS3-DFM The Serial Port Expander adds three additional slave ports for a DF1 based device. This allows users to connect programming software, HMI, and modems to processors simultaneously. Commands from the host devices are passed through the module and routed directly to the front port of the processor. This allows a processor s port to be expanded to allow communication with a variety of devices at the same time. Typical applications include local ladder configuration, local operator interface, and wireless concentrator for remote programming and data collection. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5102-DFS3-DFM The ProLinx DF1 Serial Port Expander Gateway allows you to attach up to three separate DF1 master devices to a single DF1 slave. The module is designed to act as a multiplexer, allowing simultaneous connections from multiple DF1 masters to a single DF1 slave. A common use for the module is to have an HMI panel, SCADA package, and Programming software all communicating to the same DF1 channel 0 port of the Rockwell Automation processor. The module provides a single DF1 Master port and three DF1 Slave ports. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count

120 DF1 Master Driver Polling of Command List User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DFS3-DFM DF1 Serial Port Expander Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

121 DH-485 to IEC Master Gateway 5102-DH M The ProLinx DH-485 to IEC Master Gateway creates a powerful connection between devices on a DH-485 network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one IEC 103 Master configurable serial port. DH-485 to IEC Master Gateway 5102-DH M The DH M modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate an IEC 103 slave device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

122 DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DH M DH-485 to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

123 DH-485 to ASCII Generic Serial Gateway 5102-DH485-ASCII3 The ProLinx DH-485 to ASCII Generic Serial Gateway creates a powerful connection between devices on a DH-485 network and ASCII input devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and three ASCII configurable serial ports. DH-485 to ASCII Generic Serial Gateway 5102-DH485-ASCII3 The DH485-ASCII modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate ASCII serial input device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

124 DH485 Functioning as a Master Command List Polling of command list Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count User configurable polling of commands, including disabled, continuous and on change of data (write only) ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DH485-ASCII3 DH-485 to ASCII Generic Serial Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

125 DH-485 to Honeywell DE Master Gateway 5106/5126-DH485-DEM(2) The DH485-DEM modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate Honeywell DE devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE device support, the module provides a very powerful interface to the many Honeywell DE devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DH-485 to Honeywell DE Master Gateway 5106/5126-DH485-DEM(2) The ProLinx DH-485 to Honeywell DE Master Gateway creates a powerful connection between devices on a DH-485 network and Honeywell DE devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and up to eight configurable Honeywell DE Master channels. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

126 DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module. DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source LEDs for Visual Module Status External 24 VDC source connection on the front of the DEM module provides instrument loop power DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5106-DH485-DEM DH-485 to Honeywell DE Master Gateway 5126-DH485-DEM2 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

127 DH-485 to DF1 Master/Slave Gateway 5102-DH485-DFCM3 The DH485-DFCM modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate DF1 devices into a system. The DH- 485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED DH-485 to DF1 Master/Slave Gateway 5102-DH485-DFCM3 The ProLinx DH-485 to DF1 Master/Slave Gateway creates a powerful connection between devices on a DH-485 network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and three DF1 Master or Slave configurable serial ports. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)

128 DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Full Duplex Slave (not peer mode) Half Duplex Polled Configurable Data Table File Start (File N[x] 0 to 999) parameters per slave Data Table File Size (1 to 1000 words) port Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Operating Temperature 20 to 50 C ( 4 to 122 F) Storage Temperature 40 to 85 C ( 40 to 185 F) Relative Humidity 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial DB-9M RS-232 only Port No hardware handshaking Ethernet Port (Ethernet RJ45 Connector modules only) Link and Activity LED indicators Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013 Hardware s Power Supply Current Load 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC

129 DISCONTINUED DH-485 to DNP 3.0 Master Gateway 5102-DH485-DNPM The ProLinx DH-485 to DNP 3.0 Master gateways create a powerful connection between a DH-485 device and a DNP 3.0 slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 Master or Slave configurable serial port and one DNP 3.0 master configurable serial port. DH-485 to DNP 3.0 Master Gateway 5102-DH485-DNPM The DH485-DNPS modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a DNP master device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

130 DH485 Functioning as a Master Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation DNP Master Node address Slave count Command count 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013

131 DH-485 to DNP 3.0 Slave Gateway 5102-DH485-DNPS The ProLinx DH-485 to DNP 3.0 Slave Gateway creates a powerful connection between a DH-485 device and a DNP 3.0 master device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 Master or Slave configurable serial port and one DNP 3.0 slave configurable serial port. DH-485 to DNP 3.0 Slave Gateway 5102-DH485-DNPS The DH485-DNPS modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a DNP master device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

132 DH485 Functioning as a Master Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DH485-DNPS DH-485 to DNP 3.0 Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

133 DISCONTINUED DH-485 to HART Multi-drop Gateway DH-485 to HART Multi-drop Gateway 5107/5127-DH485-HART(2) The DH485-HART modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate HART Multi-drop devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5107/5127-DH485-HART(2) The ProLinx DH-485 to HART Multi-drop Gateway creates a powerful connection between devices on a DH-485 network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and up to eight configurable HART Multi-drop channels. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

134 DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) Dimensions LED Indicators HART Configuration Serial Port The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an Ethernet Port (Ethernet RJ45 Connector individual channel basis to operate as a HART Master Station and modules only) supports all the available HART commands including Universal, Application Serial Ports Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. Serial Port Isolation The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Configurable Parameters per Channel HART Driver Command List Polling of command list Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 16, 2013

135 DH-485 to Modbus Master/Slave Gateway 5102-DH485-MCM3 The DH485-MCM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a DH-485 device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DH-485 to Modbus Master/Slave Gateway 5102-DH485-MCM3 The ProLinx DH-485 to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus network and a DH-485 master or slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 Master or Slave configurable serial port and three Modbus Master or Slave configurable serial ports. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking Communication Parameters BCC and CRC Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only)

136 Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 0 to 50 C (32 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DH485-MCM3 DH-485 to Modbus Master/Slave Gateway Note: The 5102-DH485-MCM3 is in a Final Sales Period of two years, effective October 14, 2008 until October 14, Thereafter, the product will continue to be supported until October 14, Recommended replacement product is the 5201-MNET-DH485 Modbus TCP/IP Client/Server to DH485 Master/Slave Communication Gateway. For more information on the Product Retirement Program, please visit: To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

137 DH-485 to PROFIBUS DP Master Gateway 5104-DH485-PDPM The DH485-PDPM modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a PROFIBUS DP slave device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED DH-485 to PROFIBUS DP Master Gateway 5104-DH485-PDPM The ProLinx DH-485 to PROFIBUS DP Master Gateway creates a powerful connection between devices on a DH-485 network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and PROFIBUS DP Master port. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking Communication Parameters BCC and CRC Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed

138 with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. LED Indicators Power and Module Status Application Status DH485 Functioning as a Master Serial Port Activity LED Command List Up to 100 command per master Serial Activity and Error LED Status port, each fully configurable for Configuration Serial DB-9M RS-232 only function, slave address, register to/from addressing and word/bit Port No hardware handshaking count Ethernet Port (Ethernet RJ45 Connector Polling of command list User configurable polling of modules only) Link and Activity LED indicators commands, including disabled, Application Serial Ports RS-232/422/485 continuous and on change of data RS-232 handshaking configurable (write only) RS-422/485 screw termination PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Serial Port Isolation Shipped with Each Unit included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013

139 Discontinued DH-485 to PROFIBUS DP Slave Gateway DH-485 to PROFIBUS DP Slave Gateway 5105-DH485-PDPS The DH485-PDPS modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate a PROFIBUS DP master device into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5105-DH485-PDPS The ProLinx DH-485 to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DH-485 network and a PROFIBUS DP master device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and PROFIBUS DP Slave port. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

140 DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total Supported PROFIBUS DP PROFIBUS V0 Slave using Siemens SPC3 features chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 16, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

141 DNP 3.0 Master to DF1 Master/Slave Gateway 5102-DNPM-DFCM3 The DNP-DFCM modules are the ideal solution for the many applications where DF1 connectivity can be used to integrate a DNP Slave device into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP Slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DNP 3.0 Master to DF1 Master/Slave Gateway 5102-DNPM-DFCM3 The ProLinx DNP 3.0 Master to DF1 Master/Slave Gateway creates a powerful connection between devices on a DF1 network and a DNP Slave device. This stand-alone DIN-rail mounted protocol gateway provides one DNP configurable serial port and three DF1 Master/Slave configurable serial ports. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNP Master Node address Slave count Command count DNPM Driver Manual contains full Object Definition documentation 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking BCC and CRC

142 General Parameters Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DNPM-DFCM3 DNP 3.0 Master to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

143 DNP 3.0 Master to Modbus Master/Slave Gateway 5102-DNPM-MCM3 The ProLinx DNP 3.0 Master to Modbus Master/Slave Gateway creates a powerful connection between devices on a DNP network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides up to four serial ports. DNP 3.0 Master to Modbus Master/Slave Gateway 5102-DNPM-MCM3 The DNPM-MCM modules are the ideal solution for the many applications where DNP Master connectivity can be used to integrate Modbus devices into a system. The DNP gateway is a powerful module designed with both Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation DNP Master Node address Slave count Command count 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication parameters Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms

144 General Parameters Modbus Protocol Error Checking Floating Point Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating point data movement supported, including configurable support for Enron implementation 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DNPM-MCM3 DNP 3.0 Master to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

145 DNP 3.0 Master to PROFIBUS DP Master Gateway DNP 3.0 Master to PROFIBUS DP Master Gateway 5204-DNPM-PDPM The DNPM-PDPM modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate a PROFIBUS DP Master device into a system. The DNP 3.0 Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5105-DNPM-PDPM The ProLinx DNP 3.0 Master to PROFIBUS DP Master creates a powerful connection between devices on a DNP 3.0 network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and PROFIBUS DB Slave port. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation DNP Master Node address Slave count Command count 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information.

146 General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5204-DNPM-PDPM DNP 3.0 Master to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

147 DATASHEET DNP 3.0 Master to PROFIBUS DP Slave Gateway 5105-DNPM-PDPS The ProLinx DNP 3.0 Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP 3.0 network and PROFIBUS DP master devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and PROFIBUS DB Slave port. The DNP 3.0 Master protocol supports Master implementations of the protocol on one port. This port is fully configurable. The PROFIBUS Slave protocol supports the PROFIBUS DP-V0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished, using the provided ProSoft Configuration Builder software. Features Benefits Powerful network integration Allows movement of data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port DNP 3.0 Master protocol interface DNP 3.0 Master Level 2 Connects to up to 40 slave devices Up to 300 commands PROFIBUS DP-V0 Slave protocol interface ProSoft Configuration Builder software included Adds PROFIBUS DP Slave device monitoring and control to a DNP 3.0 Master network Easy configuration - GSD file provided 122 words input/122 words output, 200 words maximum I/O Graphical drag-and-drop configuration tool for simple module configuration Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics View module database contents through serial connection to a desktop PC Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications

148 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. The PROFIBUS DP-V0 Slave driver provides a powerful and easy-to-use interface between a PROFIBUS DP network and other networks. This slave implementation gives access to up to 244 bytes of PROFIBUS Input data and up to 244 bytes of PROFIBUS Output data, with a maximum configurable limit of 400 total data bytes. These Input and Output data areas are fixed in the ProLinx gateway s data memory, allowing the user to monitor or manipulate this data with either of the installed gateway protocols. Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects. DNP 3.0 Master Functional s The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, and so on). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master - Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation DNP Master Node address Slave count Command count 0 to (software selectable) Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices PROFIBUS DP Slave Functional s GSD File Communication parameters Supported I/O length Supported PROFIBUS DP-V0 features PRLX05A5.GSD Available on Product DVD, or downloadable from ProSoft Technology web site Baud Rate: 9.6 kbps to 12 Mbps 244 bytes Input data 244 bytes Output data 400 total data bytes, maximum PROFIBUS DP-V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 0 to 125 Data byte swapping Action on loss of PROFIBUS connection Communication Fail Timeout Multiplier Status Data location in Internal Database Where Automation Connects Global Distribution ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, technical support and a three year warranty. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under About Us on the web site at: Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.

149 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Shock Vibration Dimensions (Height x Width x Depth) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) 24 Vdc nominal 18 Vdc to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma 32 Vdc maximum -4 F to 122 F (-20 C to 50 C) -40 F to 185 F (-40 C to 85 C) 5% to 95% RH with no condensation IEC ; HZ IEC ; 11ms, 3-Axis (Operational) Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration 2 DB-9F Female Modbus Plus Ports Serial Port Isolation 2500 Vrms port signal isolation per UL Vdc min. isolation port to ground and port to logic Shipped WITH Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5 mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only) Agency Approvals and Certifications ATEX CE culus CB Safety Where Automation Connects Additional Products Global Distribution ProSoft Technology offers a full complement of hardware and We software think solutions like you do for a wide variety of industrial communication ProSoft platforms. Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. For a complete list of products, visit Our knowledgeable distributors are our web site at: familiar with your application needs. For a complete list of distributors, go to our web site at: Ordering Information To order this product, please use the following: Global DNP 3.0 Support Master to We PROFIBUS are there for you DP Slave Gateway All ProSoft Technology products are backed with free, unlimited technical 5105-DNPM-PDPS support. Contact our worldwide Technical To place an Support order, please team directly contact by phone your local or . ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: Global Offices We and are select where How you to are Buy from the menu. ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Copyright 2013 ProSoft Technology, Inc., all rights reserved. 5/31/2013 s subject to change without notice.

150 DNP 3.0 Slave to DF1 Master/Slave Gateway 5102-DNPS-DFCM3 The DNPS-DFCM modules are the ideal solution for the many applications where DNP connectivity can be used to integrate DF1 Master or Slave devices into a system. The DNP 3.0 Slave gateway is a powerful module designed with level 2 Slave support, enabling easy connection between DNP masters and devices on a dissimilar network. In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DNP 3.0 Slave to DF1 Master/Slave Gateway 5102-DNPS-DFCM3 The ProLinx DNP 3.0 Slave to DF1 Master/Slave Gateway creates a powerful connection between devices on a DNP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one DNP Slave serial port and three DF1 serial ports individually configurable as either Master or Slave. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms

151 General Parameters Error Checking Miscellaneous BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DNPS-DFCM3 DNP 3.0 Slave to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

152 DNP 3.0 Slave to Modbus Master/Slave Gateway DNP 3.0 Slave to Modbus Master/Slave Gateway 5102-DNPS-MCM3 The DNPS-MCM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a DNP 3.0 Master device into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5102-DNPS-MCM3 The ProLinx DNP 3.0 Slave to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus network and a DNP master device. This stand-alone DIN-rail mounted protocol gateway provides one DNP 3.0 Slave configurable serial port, and three Modbus Master or Slave configurable serial ports. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

153 General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address support for Enron implementation 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-DNPS-MCM3 DNP 3.0 Slave to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

154 DNP 3.0 Slave to PROFIBUS DP Master Gateway DNP 3.0 Slave to PROFIBUS DP Master Gateway 5104-DNPS-PDPM The DNPS-PDPM modules are the ideal solution for the many applications where DNP connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The DNP 3.0 Slave gateway is a powerful module designed with Client support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5104-DNPS-PDPM The ProLinx DNP 3.0 Slave to PROFIBUS DP Master Gateway creates a powerful connection between devices on a PROFIBUS network and DNP devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one DB9F port configurable for PDPM. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for

155 configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply 24 VDC nominal 18 VDC to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 500 ma 24 VDC Operating Temperature 32 F to 122 F (0 C to 50 C) Storage Temperature 40 F to 185 F ( 40 C to 85 C) Relative Humidity 5% to 95% (with no condensation) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5104-DNPS-PDPM DNP 3.0 Slave to PROFIBUS DP Master Gateway To place an order please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to: Distributors Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. April 12, 2010

156 DNP 3.0 Slave to PROFIBUS DP Slave Gateway 5105-DNPS-PDPS The ProLinx DNP Slave to PROFIBUS DP Slave Gateway creates a powerful connection between DNP and PROFIBUS master devices. This stand-alone DINrail mounted protocol gateway provides one serial port and one PROFIBUS Slave port. DNP 3.0 Slave to PROFIBUS DP Slave Gateway 5105-DNPS-PDPS The DNPS-PDPS modules are the ideal solution for the many applications where PROFIBUS connectivity can be used to integrate DNP serial devices into a system. The PROFIBUS gateway is a powerful module designed with Client support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English DNP Slave Node address 0 to (software selectable) Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped

157 by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site PROFIBUS s Communication Baud Rate: 9.6 kbit/s 12 Mbit/s parameters Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total Supported PROFIBUS DP features Configurable Parameters PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5105-DNPS-PDPS DNP 3.0 Slave to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

158 DNP 3.0 over Ethernet to IEC Master Gateway 5201-DNPSNET-103M The DNPSNET-103M modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate an IEC 103 slave device into a system. The DNP over Ethernet gateway is a powerful module designed with level 2 Server support, enabling easy connection to other DNP devices. In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DNP 3.0 over Ethernet to IEC Master Gateway 5201-DNPSNET-103M The ProLinx DNP over Ethernet to IEC Master Gateway creates a powerful connection between devices on a DNP over Ethernet network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).

159 The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DNPSNET-103M DNP 3.0 over Ethernet to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

160 DNP 3.0 over Ethernet to DF1 Master/Slave Gateway 5201-DNPSNET-DFCM The DNPSNET-DFCM modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate DF1 devices into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DNP 3.0 over Ethernet to DF1 Master/Slave Gateway 5201-DNPSNET-DFCM The ProLinx DNP over Ethernet to DF1 Master/Slave Gateway creates a powerful connection between devices on a DNP over Ethernet network and DF1 Master/Slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms

161 General Parameters Error Checking Miscellaneous BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 0 to 50 C (32 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DNPSNET-DFCM DNP 3.0 over Ethernet to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

162 DH-485 to DNP 3.0 over Ethernet Gateway 5201-DH485-DNPSNET The DH485-DNPSNET modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a DH-485 device into a system. The DNP over Ethernet gateway is a powerful module designed with level 2 Server support, enabling easy connection to other DNP 3.0 devices. In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED DH-485 to DNP 3.0 over Ethernet Gateway 5201-DH485-DNPSNET The ProLinx DH-485 to DNP over Ethernet Gateway creates a powerful connection between devices on a DNP over Ethernet network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

163 DH485 Functioning as a Master Polling of command list User configurable polling of commands, Ethernet Port (Ethernet RJ45 Connector including disabled, continuous and on modules only) Link and Activity LED indicators change of data (write only) Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Copyright ProSoft Technology, Inc All Rights Reserved. December 16, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking

164 DNP 3.0 over Ethernet to Modbus Master/Slave Gateway 5201/5202-DNPSNET-MCM(4) The ProLinx DNPSNET to Modbus Master/Slave Gateway creates a powerful connection between devices on a DNP Ethernet network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. DNP 3.0 over Ethernet to Modbus Master/Slave Gateway 5201/5202-DNPSNET-MCM(4) The DNPSNET-MCM modules are the ideal solution for the many applications where DNP Ethernet connectivity can be used to integrate MCM serial devices into a system. The DNP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

165 General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DNPSNET-MCM 5202-DNPSNET-MCM4 DNP 3.0 over Ethernet to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

166 DNP 3.0 over Ethernet to PROFIBUS DP Master Gateway 5204-DNPSNET-PDPM The DNPSNET-PDPM modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a PROFIBUS DP slave device into a system. The DNP over Ethernet gateway is a powerful module designed with Client and Server support, enabling easy connection to other DNP devices. In combination with the PROFIBUS DP Master support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED DNP 3.0 over Ethernet to PROFIBUS DP Master Gateway 5204-DNPSNET-PDPM The ProLinx DNP over Ethernet to PROFIBUS DP Master Gateway creates a powerful connection between devices on a DNP over Ethernet network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Master configurable DB9F port. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.

167 PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 18, 2013

168 DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway 5205-DNPSNET-PDPS The DNPSNET-PDPS modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a PROFIBUS DP master device into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to other DNP devices. In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5205-DNPSNET-PDPS The ProLinx DNP over Ethernet to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP over Ethernet network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one PROFIBUS DP Slave configurable DB9F port. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory

169 allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5205-DNPSNET-PDPS DNP 3.0 over Ethernet to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

170 DNP 3.0 over Ethernet to Rockwell Automation Remote I/O Gateway 5210-DNPSNET-RIO The DNPSNET-RIO modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate as a Remote I/O Adapter in a system. The DNP over Ethernet gateway is a powerful module designed with Server support, enabling easy connection to other DNP devices. In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED DNP 3.0 over Ethernet to Rockwell Automation Remote I/O Gateway 5210-DNPSNET-RIO The ProLinx DNP over Ethernet to Remote I/O Gateway creates a powerful connection between devices on a DNP over Ethernet network and Remote I/O devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one Remote I/O port. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module.

171 Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Ethernet Port (Ethernet modules only) RJ45 Connector Link and Activity LED indicators Application Serial Ports RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable Software Configurable Parameters 2.5mm screwdriver Rack Number 0 to 63 CD (docs and Configuration utility) Addressing RS-422/485 DB-9 to Screw Terminal Rack Size ¼-rack, ½-rack, ¾-rack and full rack Adaptor (1 or 4, depending on ports) Starting Group 0,2,4,6 Last Rack Yes or No ProSoft Configuration Builder Baud Rate 57.6K, 115K, 230K ProSoft Configuration Builder (PCB) provides a quick Functional s and easy way to manage module configuration files Supports block-transfers of data with scanner customized to meet your application needs. PCB is not Supports I/O data movement. Amount determined by rack only a powerful solution for new configuration files, but size configuration also allows you to import information from previously BTW Command up to 64 words BTR Command up to 63 words installed (known working) configurations to new projects. Physical Connection Remote I/O connector Standard 3-screw termination connector General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 18, 2013

172 Modbus Plus to IEC Slave Gateway 5301-MBP-101S The MBP-101S modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate an IEC 101 master device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 101 Slave support, the module provides a very powerful interface to the many IEC 101 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Modbus Plus to IEC Slave Gateway 5301-MBP-101S The ProLinx Modbus Plus to IEC Slave Gateway creates a powerful connection between devices on a Modbus Plus network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one IEC 101 Slave configurable serial port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

173 IEC Slave The 101S module acts as an input/output module LED Indicators Power and Module Status between the IEC and other protocols and Application Status Serial Port Activity LED networks, as well as several proprietary interfaces. Serial Activity and Error LED Status General specifications include: Configuration Serial DB-9M RS-232 only Port User-definable module memory usage No hardware handshaking Ethernet Port (Ethernet RJ45 Connector Storage of IEC time used in module is available in modules only) Link and Activity LED indicators the database Application Serial Ports RS-232/422/485 Protocol implementation conforms to the IEC RS-232 handshaking configurable specification with fully configurable parameters RS-422/485 screw termination included Priority Queues Serial Port Isolation 2500V RMS port signal isolation per UL 1577 Invalid Bit Monitoring 3000V DC min. port to ground and Supports Balanced and Unbalanced Mode port to logic power isolation Supports CP24 and CP56 time formats for events Shipped with Each Unit Mini-DIN to DB-9M serial cables Event generation configurable per point or data type 4 ft RS-232 configuration cable General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 18, 2013

174 Modbus Plus to IEC Master Gateway 5301-MBP-103M The MBP-103M modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate an IEC 103 slave device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 103 Master support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Modbus Plus to IEC Master Gateway 5301-MBP-103M The ProLinx Modbus Plus to IEC Master Gateway creates a powerful connection between devices on a Modbus Plus network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one IEC 103 Master configurable serial port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).

175 The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013

176 Modbus Plus to IEC Server Gateway Modbus Plus to IEC Server Gateway 5303-MBP-104S The MBP-104S modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate a Modbus Plus device into a system. The IEC Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 devices. In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5303-MBP-104S The ProLinx Modbus Plus to IEC Server Gateway creates a powerful connection between devices on an IEC 104 Server network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions.

177 The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5303-MBP-104S Modbus Plus to IEC Server Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

178 . Modbus Plus to ASCII Generic Serial Gateway 5301/5302-MBP-ASCII(4) The MBP-ASCII modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate an ASCII generic serial input device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Plus to ASCII Generic Serial Gateway 5301/5302-MBP-ASCII(4) The ProLinx Modbus Plus to ASCII Generic Serial Gateway creates a powerful connection between devices on a Modbus Plus network and ASCII input devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and up to four ASCII configurable serial ports. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII

179 communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5301/5302-MBP-ASCII(4) Modbus Plus to ASCII Generic Serial Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

180 Modbus Plus to DF1 Master/Slave Gateway 5301/5302-MBP-DFCM(4) The MBP-DFCM modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate DF1 devices into a system. The Modbus Plus gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Plus to DF1 Master/Slave Gateway 5301/5302-MBP-DFCM(4) The ProLinx Modbus Plus to DF1 Master/Slave Gateway creates a powerful connection between devices on a Modbus Plus network and DF1 Slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB-9F port and up to four configurable serial ports. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, Polling of command list register to/from addressing and word count Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking BCC and CRC

181 General Parameters Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5301-MBP-DFCM 5302-MBP-DFCM4 Modbus Plus to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

182 Modbus Plus to EtherNet/IP Gateway 5303-MBP-DFNT The ProLinx Modbus Plus to EtherNet/IP Gateway creates a powerful connection between devices on an EtherNet/IP network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port. Modbus Plus to EtherNet/IP Gateway 5303-MBP-DFNT The MBP-DFNT modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate a Modbus Plus device into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The Ethernet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Polling of command list Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported

183 EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words CIP Services Supported 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5303-MBP-DFNT Modbus Plus to EtherNet/IP Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

184 Modbus Plus to DH-485 Gateway Modbus Plus to DH-485 Gateway 5301-MBP-DH485 The MBP-DH485 modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate DH-485 devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5301-MBP-DH485 The ProLinx Modbus Plus to DH-485 Gateway creates a powerful connection between devices on a Modbus Plus network and DH-485 devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus DB9F port and one DH-485 configurable serial port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

185 DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking Communication Parameters BCC and CRC Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command User configurable polling of list commands, including disabled, continuous and on change of data (write only) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 500 ma max@ 24 VDC Operating Temperature 20 to 50 C ( 4 to 122 F) Storage Temperature 40 to 85 C ( 40 to 185 F) Relative Humidity 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5301-MBP-DH485 Modbus Plus to DH-485 Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

186 Modbus Plus to DNP 3.0 Slave Gateway Modbus Plus to DNP 3.0 Slave Gateway 5301-MBP-DNPS The MBP-DNPS modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate DNP serial devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus Plus devices with peer to peer support. In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5301-MBP-DNPS The ProLinx Modbus Plus to DNP 3.0 Slave Gateway creates a powerful connection between devices on a Modbus Plus network and DNP master devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable DB9F port and one serial port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

187 DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5301-MBP-DNPS Modbus Plus to DNP 3.0 Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

188 Modbus Plus to DNP 3.0 over Ethernet Gateway Modbus Plus to DNP 3.0 over Ethernet Gateway 5303-MBP-DNPSNET The MBP-DNPSNET modules are the ideal solution for the many applications where DNP over Ethernet connectivity can be used to integrate a Modbus Plus device into a system. The DNP over Ethernet gateway is a powerful module designed with both Client and Server support, enabling easy connection to other DNP devices. In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5303-MBP-DNPSNET The ProLinx Modbus Plus to DNP over Ethernet Gateway creates a powerful connection between devices on a DNP over Ethernet network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

189 DNP 3.0 TCP/IP Server The DNPSNET protocol driver exists as a single service port (DNPSNET port 20000) implementation that supports a single TCP port connection and multiple UDP ports on a TCP/IP Ethernet network. The DNPSNET port operates as a server, supporting the DNP 3.0 protocol in a Level 2 implementation using the DNP User Group recommended extension for use on LAN/WAN. General Parameters Internal Database Binary Inputs: 8000 points (500 words) Analog Inputs: 500 points Counters: 250 (500 words) Binary Outputs: 2000 points (125 words) Analog Outputs: 500 points DNP Mode DNP 3.0 Slave Level 2 DNP Server Service Port Protocols TCP (1 connection) and UDP Node address 0 to (software selectable) The DNPSNET module accepts DNP commands to control and monitor the data stored in the DNP databases. These data are passed between the module and the other protocol on the ProLinx module. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5303-MBP-DNPSNET Modbus Plus to DNP 3.0 over Ethernet Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

190 Modbus Plus to HART Multi-drop Gateway Modbus Plus to HART Multi-drop Gateway 5307-MBP-HART The MBP-HART modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate HART Multi-drop devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART Multi-drop support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5307-MBP-HART The ProLinx Modbus Plus to HART Multi-drop Gateway creates a powerful connection between devices on a Modbus Plus network and HART devices. This standalone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and four HART Multi-drop channels. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

191 HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Configurable Parameters per Channel HART Driver Command List Polling of command list Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5307-MBP-HART Modbus Plus to HART Multi-drop Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

192 Modbus Plus to Modbus Master/Slave Gateway 5301/5302-MBP-MCM(4) The MBP-MCM modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate Modbus devices into a system. The Modbus Plus gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Plus to Modbus Master/Slave Gateway 5301/5302-MBP-MCM(4) The ProLinx Modbus Plus to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus Plus network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus port and up to four Modbus enabled serial ports. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, Polling of command list register to/from addressing and word count Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication parameters Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms

193 General Parameters Modbus Protocol Error Checking Floating Point Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating point data movement supported, including configurable support for Enron implementation 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5301-MBP-MCM 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

194 Modbus Plus to Modbus TCP/IP Gateway Modbus Plus to Modbus TCP/IP Gateway 5303-MBP-MNET The MBP-MNET modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Modbus Plus device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Modbus Plus support, the module provides a very powerful interface to the many Modbus Plus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5303-MBP-MNET The ProLinx Modbus Plus to Modbus TCP/IP Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a Modbus Plus device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one Ethernet port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. Modbus Plus The Modbus Plus protocol driver operates as a single peer-to-peer Modbus Plus Port with dual media-redundant connectors which are not configurable as separate ports. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

195 Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Modbus Plus Connector Two DB9 female standard Modbus Plus connectors 2500V RMS port signal isolation per UL VDC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver DVD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5303-MBP-MNET Modbus Plus to Modbus TCP/IP Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 9, 2014

196 Modbus Plus to PROFIBUS DP Master Gateway Modbus Plus to PROFIBUS DP Master Gateway 5304-MBP-PDPM The MBP-PDPM modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5304-MBP-PDPM The ProLinx Modbus Plus to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one PROFIBUS DP Master configurable DB9F port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

197 PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5304-MBP-PDPM Modbus Plus to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

198 DATASHEET Modbus Plus to PROFIBUS DPV1 Master Gateway 5304-MBP-PDPMV1 The ProLinx Modbus Plus to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one PROFIBUS DPV1 Master configurable DB9F port. The Modbus Plus protocol supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The PROFIBUS DPV1 Master protocol supports complete Master specifications according to IEC on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification. Features Benefits Powerful network integration Move data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port Modbus Plus protocol interface Modbus Plus serial port with dual media-redundant connectors PROFIBUS DPV1 Master protocol interface CIPConnect enabled. Module supports communications with ProSoft Configuration Builder and FDT comdtm via Ethernet routing using Rockwell Automation Ethernet interface. Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.

199 General s - ProLinx ProLinx Communication gateways provide connectivity for two or more dissimilar network types. The gateway, enclosed in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. General s - MBP Communication parameters Modbus Modes Floating Point Data Modbus Function Codes Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to milliseconds RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating point data movement supported, including configurable support for Enron implementation 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register15: Force( Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers Schematic General s - PDPMV1 The PROFIBUS DPV1 Master implementation is a powerful communication interface for processors. Developed under license from, the module incorporates proprietary backplane technology that enables powerful data exchange with processors. The module supports complete Master specifications according to IEC Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor. Data transfer from the processor is asynchronous with the I/O data transfer on the PROFIBUS network.

200 Functional s - Modbus Plus The Modbus Plus protocol (MBP) operates as a single, peer-to-peer, Modbus Plus Port with dual media-redundant connectors, which are not configurable as separate ports. General Parameters Modbus Function Codes Address Scope 1 to 64 Modbus Plus Functioning as a Master 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words per node max.) Global data write (32 words per node max.) Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous read or write commands and write on change of data (Function Code 16 Write command only)" Modbus Plus Functioning as a Slave Node address 1 to 64 (software selectable) Functional s - PROFIBUS DP Master V1 Easy-to-use drag and drop Master Busview configuration interface via ProSoft Configuration Builder software Project-unique GSD file import library Monitoring and Modification of process data and DPV1 acyclic data Multi-drop on a PROFIBUS DPV1 network with other compatible devices Automatic project documentation Automatic Bus Parameter calculation Online slave diagnostics Supports all standardized baud rates, up to 12Mbps Supports extended diagnostic data (DPV1) Auto baud detection at all valid PROFIBUS DPV1 rates CRC checksum determination of slave configuration consistency to processor Master Status LED Indicators for Operations, Network Communication, Master Token-Hold and Network Configuration. FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM) Up to 125 Slaves can be connected with a repeater Up to 1536 cyclic bytes input and 1536 bytes output data Supports Extended Diagnostic Data RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter Acyclic communications (DPV1), Read and Write Alarm Handling (DPV1) Supports Sync and Freeze commands Supports PROFIdrive 3.1 compliant parameter read and write operations Supports Multicast and Broadcast telegrams (DPV1) Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.

201 Hardware s Power Supply 24 Vdc nominal 18 to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 500 ma 32 Vdc maximum Operating Temperature -4 F to 122 F (-20 C to 50 C) Storage Temperature Relative Humidity Dimensions (Height x Width x Depth) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) -40 F to 185 F (-40 C to 85 C) 5 to 95% (without condensation) Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols. Serial Port Isolation 2500 Vrms port signal isolation per UL Vdc min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only) Agency Approvals & Certifications culus ISA Class I, Div 2 Groups A, B, C, D culus C22.2 No. 213-M Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: Modbus Plus to PROFIBUS DPV1 Master Gateway 5304-MBP-PDPMV1 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com fax to Europe / Middle East / Africa europe@prosoft-technology.com fax to +33 (0) Copyright 2010 ProSoft Technology, Inc., all rights reserved. 10/19/2010 s subject to change without notice.

202 Modbus Plus to PROFIBUS DP Slave Gateway 5305-MBP-PDPS The ProLinx Modbus Plus to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and PROFIBUS DP Slave configurable DB9F port. Modbus Plus to PROFIBUS DP Slave Gateway 5305-MBP-PDPS The MBP-PDPS modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a PROFIBUS DP master device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS DP master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Address Scope 1 to 64 Modbus Plus Functioning as a Master Command List Polling of command list Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.

203 General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5305-MBP-PDPS Modbus Plus to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

204 Modbus Plus to Rockwell Automation Remote I/O Gateway 5310-MBP-RIO The MBP-RIO modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a Remote I/O device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Modbus Plus to Rockwell Automation Remote I/O Gateway 5306-MBP-RIO The ProLinx Modbus Plus to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on a Modbus Plus network and a Remote I/O device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and Remote I/O port. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable

205 Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected Configuration Serial to a scanner (master) that controls the data transfer. For Port example, the master/slave relationship can be Ethernet Port (Ethernet accomplished using the RIO module (adapter/slave unit) modules only) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Application Serial Ports Serial Port Isolation DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activityity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and Software Configurable Parameters Rack Number 0 to 63 port to logic power isolation Addressing Shipped with Each Unit Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Copyright ProSoft Technology, Inc All Rights Reserved. December 18, 2013

206 Modbus Serial Port Expander Gateway Modbus Serial Port Expander 5102-MBS3-MBM The Serial Port Expander adds three additional slave ports for a Modbus based device. This allows users to connect SCADA software, HMI, and modems to processors simultaneously. Commands from the host devices are passed through the module and routed directly to the front port of the processor. This allows a processor s port to be expanded to allow communication with a variety of devices at the same time. Typical applications include SCADA software, local operator interface, and wireless concentrator for remote data collection. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English 5102-MBS3-MBM The ProLinx Modbus Serial Port Expander module allows you to attach up to three separate Modbus master devices to a single Modbus slave. The module is designed to act as a multiplexer, allowing simultaneous connections from multiple Modbus masters to a single Modbus slave. A common use for the module is to have an HMI panel and a SCADA package all communicating to the same Modbus slave port of a Modicon processor. This stand-alone DIN-rail mounted protocol gateway provides a single Modbus Master port and three Modbus Slave ports. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. Modbus The serial port(s) on the gateway can be individually configured to support the Modbus protocol (RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication parameters Error Checking Function Codes Modbus Slave Node address Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms RTU mode (binary) with CRC-16 ASCII mode with LRC error checking 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register 1 to 247 software selectable Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

207 General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-MBS3-MBM Modbus Serial Port Expander To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 16, 2007

208 Modbus Master/Slave to IEC Slave Gateway 5102-MCM3-101S The MCM-101S modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC 101 master device into a system. The IEC Slave gateway is a powerful module designed with Slave support, enabling easy connection to an IEC 101 master device. In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to IEC Slave Gateway 5102-MCM3-101S The ProLinx Modbus Master/Slave to IEC Slave Gateway creates a powerful connection between devices on a Modbus network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one IEC 101 Slave configurable serial port and three Modbus Master or Slave configurable serial ports. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

209 IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-MCM3-101S Modbus Master/Slave to IEC Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

210 IEC Master to Modbus Master/Slave Gateway 5102-MCM-103M The MCM-103M modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate an IEC slave device into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Modbus devices (Modicon processors and many others). In combination with the IEC 103 device support, the module provides a very powerful interface to the many IEC 103 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to IEC Master Gateway 5102-MCM-103M The ProLinx Modbus Master/Slave to IEC Master Gateway creates a powerful connection between devices on a Modbus network and an IEC 103 slave device. This stand-alone DINrail mounted protocol gateway provides one Modbus Master or Slave configurable serial port and one IEC 103 Master configurable serial port. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

211 IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-MCM-103M IEC Master to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

212 Modbus Master/Slave to 'C' Programmable Application Development Module 5102-MCM4-ADM4 The 5102 MCM4-ADM4 module is the ideal solution for many applications where serial connectivity needs to be added to a Modbus Master/Slave platform. Example applications involving the 5102 MCM4-ADM4 module include: Bar code scanner interface Legacy ASCII protocol connections Terminal port emulation Printer driver (alarm/status printer) Customized protocol implementations How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to 'C' Programmable Application Development Module 5102-MCM4-ADM4 The ProLinx 'C' Programmable Application Development Module provides a powerful platform for bridging communications between your custom serial protocols. This stand-alone DIN-rail mounted protocol gateway provides four fully programmable serial ports. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

213 General Parameters Modbus Protocol Polling of command list Modbus Slave Node address Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable ADM The ADM API Suite allows software developers to access the serial ports without needing detailed knowledge of the module's hardware design. The ADM API Suite consists of two distinct components: the Serial Port API and the ADM API. Applications for the ADM module may be developed using industrystandard DOS programming tools and the appropriate API components. The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers. Development Environment Operating system: General software DOS 6-XL Compatible compiler (16-bit DOS target) o Digital Mars C++ V8.49 (included) o Borland C++ V5.02 Application Programming Interfaces (API) Serial Port API: serial port functions Backplane API: low level backplane functions ADM API debug port functions: debug port functions, database functions timer functions, high level backplane transfer functions, LED functions, flash read functions General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-MCM4-ADM4 Modbus Master/Slave to 'C' Programmable Application Development Module To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

214 Modbus Master/Slave to ASCII Generic Serial Gateway 5102-MCM-ASCII3 The ProLinx Modbus Master/Slave to ASCII Generic Serial Gateway creates a powerful connection between devices on a Modbus network and ASCII devices. This stand-alone DIN-rail mounted protocol gateway provides one Modbus configurable serial port and three ASCII configurable serial ports. Modbus Master/Slave to ASCII Generic Serial Gateway 5102-MCM-ASCII3 The MCM-ASCII modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate ASCII serial devices into a system. The Modbus gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication parameters Error Checking Floating Point Function Codes Modbus Master Command List Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating point data movement supported, including configurable support for Enron implementation 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

215 General Parameters Modbus Protocol Polling of command list Modbus Slave Node address Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-MCM-ASCII3 Modbus Master/Slave to ASCII Generic Serial Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

216 Modbus Master/Slave to Honeywell DE Master Gateway 5106/5126-MCM-DEM(2) The MCM-DEM modules are the ideal solution for the many applications where DEM connectivity can be used to integrate Modbus serial devices into a system. The Honeywell DE gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Modbus Master/Slave to Honeywell DE Master Gateway 5106/5126-MCM-DEM(2) The ProLinx Modbus Master/Slave to Honeywell DE Master Gateway creates a powerful connection between devices on a Honeywell DE network and Modbus devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable serial port and one 8 channel DEM block. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

217 Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module. DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source LEDs for Visual Module Status External 24 VDC source connection on the front of the DEM module provides instrument loop power DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013 Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators

218 Modbus Master/Slave to DF1 Master/Slave Gateway 5102-MCM4-DFCM4 This module is fully configurable, allowing any of its four serial ports to be configured as either a Master or Slave utilizing either the DF1 or Modbus Protocols. This provides a great deal of application flexibility as the module can be used as a data concentrator (when configuring all four ports for the same protocol) or the module database can be shared between the DF1 and Modbus networks to allow the module to work as a bridge between the two different protocols. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to DF1 Master/Slave Gateway 5102-MCM4-DFCM4 The ProLinx Modbus Master/Slave to DF1 Master/Slave Gateway creates a powerful connection between Modbus Master/Slave and DF1 Master/Slave networks and devices. This stand-alone DIN-rail mounted protocol gateway provides four serial ports, each individually configurable as a Modbus or DF1 Master or Slave. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

219 DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5102-MCM4-DFCM4 Modbus Master/Slave to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

220 Modbus Master/Slave to HART Multi-drop Gateway 5107/5127-MCM-HART(2) The MCM-HART modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate HART serial devices into a system. The Modbus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART device support, the module provides a very powerful interface to the over two-million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to HART Multi-drop Gateway 5107/5127-MCM-HART(2) The ProLinx Modbus Master/Slave to HART Multi-Drop Gateway creates a powerful connection between devices on a Modbus network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and up to eight configurable HART channels. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

221 HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Configurable Parameters per Channel HART Driver Command List Polling of command list Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5107-MCM-HART 5127-MCM-HART2 Modbus Master/Slave to HART Multi-drop Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

222 Modbus Master/Slave to PROFIBUS DP Master Gateway 5104-MCM-PDPM The MCM-PDPM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus Master/Slave gateway is a powerful module designed with Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to PROFIBUS DP Master Gateway 5104-MCM-PDPM The ProLinx Modbus Master/Slave to PROFIBUS Master Gateway creates a powerful connection between devices on a Modbus network and a PROFIBUS DP Slave device. This stand-alone DINrail mounted protocol gateway provides one serial port and one PROFIBUS Master DB9F port. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi- Master network. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

223 PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5104-MCM-PDPM Modbus Master/Slave to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

224 DATASHEET Modbus Serial to PROFIBUS DPV1 Master Gateway 5104-MCM-PDPMV1 The ProLinx Modbus Master/Slave to PROFIBUS DPV1 Master gateway creates a powerful connection between devices on a Modbus serial network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS Master DB9F port. The Modbus protocol supports both Master and Slave implementations. All Modbus serial ports are individually configurable, providing a choice of Modbus RTU or Modbus ASCII serial protocol support. The PROFIBUS DPV1 Master protocol supports complete Master specifications according to IEC Version 1 on either a single or multiple Master network. The gateway offers both cyclic and acyclic data transfers from PROFIBUS DPV1 slaves, as well as cyclic data transfers from DPV0 slaves. Features Benefits Powerful network integration Allows movement of data between dissimilar networks using two communication protocols on one gateway Protocols share access to a common memory database to exchange data between networks View diagnostic data for both networks from a single configuration/debug port Modbus slave protocol interface Emulate Modbus slave device on each individually-configurable application port Supports Modbus RTU and Modbus ASCII protocol versions Floating point data movement supported, including support for Enron, Daniel, and other implementations Suitable for SCADA and field device interface applications PROFIBUS DPV1 Master protocol interface Supports cyclic communications in V0 and both cyclic and acyclic communications in V1 Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.

225 Modbus Serial Port s - PLX Communication parameters Modbus Modes Modbus Function Codes Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to milliseconds RTU mode (binary) with CRC-16, ASCII mode with LRC error checking 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register15: Force( Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers General s - PDPMV1 Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services, allowing communication with slave devices supporting PROFIBUS DPV0 or V1 protocols. The gateway acts as a link between the PROFIBUS network and the other gateway protocol. Data transfer by the other protocol is asynchronous from data transfer on the PROFIBUS network. Functional s Modbus Master A port configured as a virtual Modbus Master actively issues Modbus commands to other nodes on the Modbus network. The Master ports have an optimized polling characteristic that polls slaves with communication problems less frequently. Command List Up to 100 command per Master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Polling of command list Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained per active Modbus Master port. Modbus Slave A port configured as a Modbus slave permits a remote Master to interact with all data contained in the module. This data can be derived from other Modbus slave devices on the network, through a Master port, or from the gateway. Node address Status Data 1 to 247 (software selectable) Error codes, counters and port status available per configured slave port Functional s - PROFIBUS DP Master V1 Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services, allowing communication with slave devices supporting PROFIBUS DPV0 or V1 protocols. The gateway acts as an input/output link between the PROFIBUS network and the other gateway protocol. Data transfer by the other protocol is asynchronous from data transfer on the PROFIBUS network. Easy-to-use drag and drop Master Busview configuration interface via ProSoft Configuration Builder software Project-unique GSD file import library Monitoring and Modification of process data and DPV1 acyclic data Multi-drop on a PROFIBUS DPV1 network with other compatible devices Automatic project documentation, and Bus Parameter calculation Supports online slave diagnostics, and extended diagnostic data (DPV1) Auto baud detection at all valid PROFIBUS DPV1 rates up to 12Mbps CRC checksum determination of slave configuration consistency to processor Master Status LED Indicators for Operations, Network Communication, Master Token- Hold and Network Configuration. Up to 125 Slaves can be connected with a repeater Up to 1536 cyclic bytes input and 1536 bytes output data Supports Extended Diagnostic Data RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter Alarm Handling (DPV1) Supports Sync and Freeze commands Supports PROFIdrive 3.1 compliant parameter read and write operations Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.

226 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions (Height x Width x Depth) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) 24 Vdc nominal 18 to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma 32 Vdc maximum -4 F to 122 F (-20 C to 50 C) -40 F to 185 F (-40 C to 85 C) 5 to 95% (with no condensation) Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols. Serial Port Isolation 2500 Vrms port signal isolation per UL Vdc min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only) Agency Approvals & Certifications culus ISA Class I, Div 2 Groups A, B, C, D culus C22.2 No. 213-M1987 Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: Modbus Serial to PROFIBUS DPV1 Master Gateway 5104-MCM-PDPMV1 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: technology.com and select Where to Buy from the menu Copyright 2016 ProSoft Technology, Inc. All rights reserved. 8/24/2016 s subject to change without notice.

227 Modbus Master/Slave to PROFIBUS DP Slave Gateway 5105-MCM-PDPS The PROFIBUS DP slave interface enables Siemens PLCs or a similar host supporting the PROFIBUS DP protocol to exchange data with other protocols. As such, possible applications of the PDPS product exist in nearly every sector of industry. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus Master/Slave to PROFIBUS DP Slave Gateway 5105-MCM-PDPS The ProLinx Modbus Master/Slave to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus network and PROFIBUS DP master devices. This stand-alone DINrail mounted protocol gateway provides one configurable serial port and one DB9F PDPS port. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

228 PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5105-MCM-PDPS Modbus Master/Slave to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

229 Modbus TCP/IP to IEC Slave Gateway 5201-MNET-101S The ProLinx Modbus TCP/IP to IEC Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and an IEC 101 master device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 101 Slave configurable serial port. Modbus TCP/IP to IEC Slave Gateway 5201-MNET-101S The MNET-101S modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 101 master device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 101 Slave support, the module provides a very powerful interface to the many IEC 101 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database

230 Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-101S Modbus TCP/IP to IEC Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

231 Modbus TCP/IP to IEC Master Gateway Modbus TCP/IP to IEC Master Gateway 5201-MNET-103M The MNET-103M modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 103 slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC 103 Master support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201-MNET-103M The ProLinx Modbus TCP/IP to IEC Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

232 IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-103M Modbus TCP/IP to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

233 Modbus TCP/IP to IEC Server Gateway Modbus TCP/IP to IEC Server Gateway 5201-MNET-104S The MNET-104S modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 104 master device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC Server device support, the module provides a very powerful interface to the many IEC 104 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201-MNET-104S The ProLinx Modbus TCP/IP to IEC Server Gateway creates a powerful connection between devices on a Modbus TCP/IP network and IEC 104 client devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

234 IEC Server Operating in the Server mode, the protocol driver accepts commands from an IEC Client to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fullyconfigured databases in the module to control outputs and monitor inputs. IEC Server Configurable Override StartDT Parameters Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-104S Modbus TCP/IP to IEC Server Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

235 DATASHEET Modbus TCP/IP to 'C' Programmable Serial 4 Port Gateway 5202-MNET-ADM4 The ProLinx 'C' Programmable Application Development Module to Modbus TCP/IP creates a powerful platform for developing and running 'C' applications to communicate with Modbus TCP/IP networks and devices. The gateway provides one Ethernet port and four serial ports. The Modbus TCP/IP protocol driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP for communicating over Ethernet networks. The gateway offers both Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections. The driver recognizes both Modbus TCP/IP MBAP and Encapsulated Modbus messages. The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6- XL. This operating system provides DOS compatibility along with real-time multitasking functionality. DOS compatibility allows user applications to be developed using standard DOS tools, such as DigitalMars and Borland compilers. Features Benefits Powerful network integration Communicate between dissimilar networks Shared database exchanges information from devices on both networks View diagnostics between both networks Modbus TCP/IP protocol interface Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols Suitable for SCADA and "foreign device" interface applications Floating point data movement supported, including configurable support for Enron and Daniel floating point applications Communicate with programmable controllers, intelligent devices, sensors and instruments Allows PCs and HMIs to monitor field devices 'C' Programmable Develop and deploy 'C' applications for a custom implementation, or to protect a proprietary algorithm Interface Modbus TCP/IP devices to serial devices such as bar code scanners, alarm/status printers, terminal port emulation, and legacy serial protocols Up to four fully programmable serial ports available Rapidly create specialized applications using a familiar programming language Libraries include functions for backplane, ports, configuration, and data communication Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration The 'C' Programmable modules are completely configurable. The included API offers the option of text or binary configuration files, configuration through ladder logic, or hardcoded configuration within the application.

236 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. Modbus TCP/IP ProSoft s Modbus TCP/IP implementation uses the gateway s shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks. Configurable floating point data movement is supported, including support for Enron or Daniel floating point applications. Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages.. Supports five independent server connections for Service Port 502 (MBP) Supports five independent server connections for Service Port 2000 (Encapsulated) Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination of data types throughout the memory database Modbus data types overlap in the gateway s memory database, so the same data can be conveniently read or written as bit-level or register-level data. Modbus TCP/IP Client (Master) Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats Offers one client connection with up to 100 commands to talk to multiple severs Status Data Error codes, counters, and port status available Schematic 'C' Programmable The ADM API Suite allows software developers to access the serial ports without needing detailed knowledge of the module s hardware design. The ADM API Suite consists of two distinct components: the Serial Port API and the ADM API. Applications for the ADM module may be developed using industry-standard DOS programming tools and the appropriate API components. Development Environment Operating system: General software DOS 6-XL Compatible compiler (16-bit DOS target) o Digital Mars C++ V8.49 (included) o Borland C++ V5.02 SDK Includes ADM API LIB (library) File ADM API Header File Complete API Documentation Image file creation utility Image file download utility DigitalMars 'C' compiler General software DOS 6-XL Example Code Files Functional s Modbus TCP/IP Modbus Commands Supported (Client and Server) Configurable Parameters: (Client and Server) 1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers Gateway IP Address, Modbus data type starting address offsets, Floating point start address and database offset

237 Modbus TCP/IP (continued) Configurable Parameters: Client Only Command List Status Data Command List Polling 'C' Programmable Minimum Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully-configurable Client commands Error codes reported individually for each command Each command can be individually enabled or disabled; write-only-on-data-change is available Each API provides a library of function calls. This library supports any programming language that is compatible with the 'C' calling convention. Initialization Open and close the API Debug Port Database Timer LED Flash Debug port user interface Read and write data to database Start and check timers Set user LED indicators Parse configuration files Hardware s Power Supply 24 VDC nominal, 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 500 ma max@ 32 VDC max Operating -20 to 50 C (-4 to 122 F) Temperature Storage Temperature -40 to 85 C (-40 to 185 F) Relative Humidity 5% to 95% (non-condensing) Dimensions 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status Configuration Serial DB-9M RS-232 only, No hardware handshaking Port Ethernet Port 10Base-T half duplex RJ45 Connector (Ethernet protocol Link and Activity LED indicators gateways only) Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration Application Serial RS-232/422/485 Ports RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) Agency Approval & Certification UL/cUL ISA Class I, Div 2 Groups A, B, C, D cul C22.2 No. 213-M1987 Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information If you are unsure which product to select, please contact your local distributor. To order this product, please use the following: Modbus TCP/IP to 'C' Programmable Gateway 5202-MNET-ADM4 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe / Middle East / Africa europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. June 02, 2009 s subject to change without notice

238 Modbus TCP/IP to ASCII Generic Serial Gateway Modbus TCP/IP to ASCII Generic Serial Gateway 5201/5202-MNET-ASCII(4) The MNET-ASCII modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate ASCII generic serial input devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201/5202-MNET-ASCII(4) The ProLinx Modbus TCP/IP to ASCII Generic Serial Gateway creates a powerful connection between devices on a Modbus TCP/IP network and ASCII input devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four ASCII configurable serial ports. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

239 ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-ASCII 5202-MNET-ASCII4 Modbus TCP/IP to ASCII Generic Serial Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

240 DATASHEET Modbus TCP/IP to BACnet/IP Client Gateway 5201-MNET-BACNET The ProLinx Modbus TCP/IP to BACnet/IP Client Gateway creates a powerful connection between devices on a Modbus TCP/IP network and BACNET devices. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port. The Modbus TCP/IP driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP. The driver allows Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. The BACnet protocol provides mechanisms by which computerized equipment of arbitrary function may exchange information, regardless of the particular building service it performs. As a result, the BACnet protocol may be used by head-end computers, general-purpose direct digital controllers, and application specific or unitary controllers with equal effect. Features Benefits Powerful network integration Communicate between dissimilar networks Shared database exchanges information from devices on both networks View diagnostics between both networks Modbus TCP/IP protocol interface Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols Suitable for SCADA and "foreign device" interface applications Floating point data movement supported, including configurable support for Enron and Daniel floating point applications Communicate with programmable controllers, intelligent devices, sensors and instruments Allows PCs and HMIs to monitor field devices BACnet/IP Client Standard protocol for Building Automation and Control limited to Analog and Digital I/O commands Communicate with Building Automation controllers, HVAC, Fire and Safety equipment Support for Trane Building Control Unit (BCU) Easy to Configure and Monitor Graphical drag-and-drop configuration tool for simple module configuration LED diagnostics for at-a-glance health check Easy to use diagnostics window with menu-driven hardware and protocol diagnostics View module database contents through serial connection to a desktop PC Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. The 5201-MNET-BACNET Setup Guide and sample configuration provide a quick and easy example with step-by-step instructions on how to move data from one network to the other.

241 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. Modbus TCP/IP ProSoft s Modbus TCP/IP implementation uses the module s shared internal memory for data transfer. Sharing the memory with another protocol driver allows the module to transfer data between Modbus TCP/IP devices and other devices on other networks. Configurable floating-point data movement is supported, including support for Enron or Daniel floating-point applications. Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages.. Supports five independent server connections for Service Port 502 (MBAP) Supports five independent server connections for Service Port 2000 (Encapsulated) Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination of data types throughout the memory database Modbus data types overlap in the gateway s memory database, so the same data can be conveniently read or written as bit-level or register-level data. Modbus TCP/IP Client (Master) Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats Offers one client connection with up to 100 commands to talk to multiple severs Status Data Error codes, counters, and port status available BACnet/IP Client The BACnet driver supports a single UDP client to interface with one or more devices that contain a BACnet/IP server The ProLinx BACnet/IP driver implements a limited subset of the BACnet/IP protocol primarily used with the Trane BCU The module controls the read/write data transfer between the gateway and other BACnet/IP devices Functional s Modbus TCP/IP Modbus Commands Supported (Client and Server) Configurable Parameters: (Client and Server) Configurable Parameters: Client Only Command List Status Data Command List Polling 1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers Gateway IP Address Modbus data type starting address offsets Floating point start address and database offset Minimum Command Delay Response Timeout Retry Count Command Error Pointer Up to 100 fully-configurable Client commands Error codes reported individually for each command Each command can be individually enabled or disabled; write-only-on-data-change is available BACnet/IP Client The BACnet/IP (Building Automation and Control networking) protocol is designed specifically to meet the communication needs of building automation and control systems for applications such as heating, ventilating, and air-conditioning control, lighting control, access control, and fire detection systems. The BACnet/IP Client can be used to interface many different protocols with Ethernetenabled BACnet devices. Schematic

242 BACnet/IP General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Service Port 1 to Function Code 12=Read Single Property 14=Read Multiple Properties 15=Write Single Property 16=Write Multiple Property. Data Type 0=Analog Input 1=Analog Output 3=Binary Input 4=Binary Output. Point Count 1 to 25 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Ports 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20 H x 2.07 W x 4.52 D inches (13.2 cm H x 5.25 cm W x 11.48cm D) Extended: 5.20 H x 2.73 W x 4.52 D inches (13.2 cm H x cm W x 11.48cm D) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking 10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. isolation port to ground and port to logic Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) Agency Approval & Certification UL/cUL ISA Class I, Div 2 Groups A, B, C, D cul C22.2 No. 213-M1987 Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information If you are unsure which product to select, please contact your local distributor. To order this product, please use the following: Modbus TCP/IP to BACnet/IP Client Gateway 5201-MNET-BACNET To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe / Middle East / Africa europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. July 15, 2009 s subject to change without notice

243 Modbus TCP/IP to BOSCH Packaging Machinery Gateway Modbus TCP/IP to BOSCH Packaging Machinery Gateway 5201/5202-MNET-BSCH(4) The MNET-BSCH modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate BOSCH Packaging Machinery devices into a system. The Modbus TCP/IP gateway in combination with the BOSCH Packaging Machinery device support, provides a very powerful interface to the many BOSCH devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201/5202-MNET-BSCH(4) The ProLinx Modbus TCP/IP to BOSCH Packaging Machinery Gateway creates a powerful connection between devices on an EtherNet/IP network and BOSCH packaging machinery. The module provides a single Ethernet port and up to four BOSCH configurable serial ports. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The BOSCH Master protocol driver supports Master implementations of the protocol on up to four ports. Each of the ports is individually configurable. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port BOSCH Packaging Machinery The BOSCH Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the BOSCH protocol (Master, Error Checking, Baud rate, etc).

244 General Parameters Type Internal Database BOSCH Modes Error Checking s BOSCH Master Driver Type s General Configurable Parameters per Master port BOSCH Commands supported Command List Status Data Polling of command list 4000 registers (words) available Full-Duplex BCC Full-Duplex, Point to Point Min Command Delay, Number of Commands, Response Timeout, Retry Count, Slave List Error Pointer 0x00 Protected Write 0x01 Unprotected Read Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port. User configurable polling of commands, including disabled, continuous and on change of data (write only) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-BSCH 5202-MNET-BSCH4 Modbus TCP/IP to BOSCH Packaging Machinery Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

245 DATASHEET Modbus TCP/IP to CC-Link Local & Intelligent Station Gateway 5209-MNET-CCLINK ProSoft Technology's Modbus TCP/IP to CC-Link communication gateway allows Schneider Electric control platform users to integrate CC-Link Master compatible products with existing Modbus TCP/IP control networks. The Modbus TCP/IP driver supports Schneider Electric processors as well most other devices that use Modbus TCP/IP. The driver allows Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. An optional web interface can be ordered separately to add FTP (ftp://) support. The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network. Features Benefits Powerful network integration Communicate between dissimilar networks A shared word database exchanges information from devices on both networks Allows integration of Modbus TCP/IP-based systems into a CC-Link Master-controlled network Modbus TCP/IP Client and/or Server communication configurations supported Five simultaneous Server connections on TCP/IP Service Port 502 and five additional Server connections on any unreserved service port (typically TCP/IP Service Port 2000) One Client connection supports up to 100 commands to interface with processors or other Server-based devices CC-Link Intelligent or Local Compatible with CC-Link Version 1.10 Station Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station As a Local Station, provides a read-only list of all network slaves cyclic and status data CC-Link Partner Association (CLPA) Certification Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.

246 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation. Schematic Modbus TCP/IP ProSoft's Modbus TCP/IP implementation uses the gateway's shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks. Floating point data movement is supported, including configurable support for Enron or Daniel floating point implementations. Modbus Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using the Modbus TCP/IP MBAP message format and from clients on Service Port 2000 (or other Service Ports) for clients using the Encapsulated Modbus message format. Supports five independent server connections for Service Port 502 Supports five independent server connections for Service Port 2000 Supports a total Modbus TCP/IP data transfer capacity of up to 4000 registers or up to 64,000 bits in any combination Modbus data types overlap in the gateway's memory database, so the same data can be read or written as bit-level or register-level data, whichever is most convenient. Modbus Client (Master) Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats Offers one client connection with up to 100 commands to talk to multiple severs Status Data Error codes, counters, and port status available CC-Link CC-Link (Control & Communication Link) is an open-standard communication protocol that enables easy connection to Mitsubishi and other Master controllers. CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide. The ProLinx CCLINK interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer. The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector.

247 Functional s Modbus TCP/IP Modbus Commands Supported (Server and Client) Configurable Parameters: Server 1 : Read Coils 2 : Read Input Status 3 : Read Holding Registers 4 : Read Input Registers 5 : Force (Write) Single Coil 6 : Preset (Write) Single Holding Register 15 : Force (Write) Multiple Coils 16 : Preset (Write) Multiple Holding Registers ProLinx IP Address Modbus data type starting address offsets Configurable parameters: Client Min Command Delay Response Timeout Retry Count Command Error Pointer Command List Status Data Polling of command list CC-Link Up to 100 fully-configurable Client commands Error codes reported individually for each command Each command can be individually enabled or disabled; write-only-on-data-change is available CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing its I/O data transfer capacity. Maximum Number of Occupied Stations Maximum Number of Devices per network Device Types Supported CC-Link Version supported Message handling Cyclic Data Capacity Additional I/O Data Transfer Capacity Transient Message Commands Communication speed Transmission path format Transmission format Error control system 4 stations, consecutive addresses Devices depending on Local and Slave Stations configured Intelligent Device and Local Station CC-Link Version 1.10 cyclic data transmission Cyclic Messages and Transient Messages 24 input data words and 24 output data words. Up to 4 slave stations supporting 4 words/32 bits per slave Transient Messaging extends the data transfer capacity to more than 8,000 additional words System Information, Memory Access Information, RUN, STOP, Line Test. Memory Read and Memory Write commands 10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps Bus format (EIA RS485 conformance) HDLC conformance CRC (X16+X12+X5+1) Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Conformance Testing Conformance testing through the CC-Link partner Association (CLPA) ensures that the gateway meets the performance specifications required to become CC-Link certified.

248 Hardware s Power Supply 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, and Ground terminals 2.5 mm screwdriver blade-sized terminals Current Load 500 ma max@ 32 VDC max Operating Temperature -20 to 50 C (-4 to 122 F) Storage Temperature -40 to 85 C (-40 to 185 F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) General LED Indicators Power and General Status Application Status Serial Port Activity LED Serial Activity and Error LED Status CC-Link LED Indicators Run (Network Status) L Run (Data Link Execution) L Err (Data Link Comm Error) SD (Sending Data LED) RD (Receiving Data LED) ERR (Switch Setting Error) Configuration Serial Port DB-9M RS-232 only No hardware handshaking Ethernet Port RJ45 Connector, 10Mbit, half-duplex only Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration CC-Link Interface Pin DA Data Communication line A DB Data Communication line B DG Digital Ground SLD Shield FG Frame Ground Shipped with Each Unit Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) CC-Link to Terminal Block connector Agency Approval & Certification ISA CC-Link Partner Association Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following. If you are unsure which product to select, please contact your local distributor. Modbus TCP/IP to CC- Link Local Station & Intelligent Device Gateway 5209-MNET-CCLINK To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. 11/7/2013 s subject to change without notice.

249 Modbus TCP/IP to Honeywell DE Master Gateway 5206-MNET-DEM The MNET-DEM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate Honeywell DE slave devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Honeywell DE Master support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Modbus TCP/IP to Honeywell DE Master Gateway 5206-MNET-DEM The ProLinx Modbus TCP/IP to Honeywell DE Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Honeywell DE slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and eight Honeywell DE Master configurable channels. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Module IP Address Parameters Modbus address offsetting Modbus TCP/IP Client General Configurable parameters Command List Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

250 Honeywell DE Master The ProLinx DEM Protocol Driver is designed to Configuration Serial interface with up to 8 DE devices. Data is exchanged Port between the DE instruments and the driver using the Ethernet Port (Ethernet internal database contained in the DEM module. modules only) DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power LEDs for Visual Module Status DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013

251 Modbus TCP/IP to DF1 Master/Slave Gateway 5201-MNET-DFCM and 5202-MNET-DFCM4 The MNET-DFCM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate DF1 devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the DF1 Master/Slave device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus TCP/IP to DF1 Master/Slave Gateway 5201-MNET-DFCM and 5202-MNET-DFCM4 The ProLinx Modbus TCP/IP to DF1 Master/Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. The Modbus TCP/IP protocol driver supports Client and Server connections, connecting many different devices into Schneider Electric Quantum processors, as well other solutions supporting the protocol. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Command parameters, Min Command Delay, Response Timeout, Retry Count, and more Up to 100 fully configurable commands on the Client port DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd Error Checking Miscellaneous RTS Timing delays: 0 to ms BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support; Floating point data supported

252 DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex or Half-Duplex Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Ethernet Port (Ethernet modules only) Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 0 to 50 C (32 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status RJ45 Connector Link and Activity LED indicators DB-9M RS-232 only No hardware handshaking Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order these products, please use the following: 5201-MNET-DFCM 5202-MNET-DFCM4 (One DF1 Master/Slave Serial Port) (Four DF1 Master/Slave Serial Ports) The 5201-MNET-DFCM-WEB is in a Final Sales Period of two years, effective October 14, 2008 until October 14, Thereafter, the product will continue to be supported until October 14, The recommended replacement for this product is 5201-MNET-DFCM. Only the WEB option version of this product is being discontinued. For more information on the Product Retirement Program,please visit: com/products/product_retirement_program To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

253 DATASHEET Modbus TCP/IP to EtherNet/IP Gateway 5201-MNET-DFNT The ProLinx Modbus TCP/IP to EtherNet/IP Gateway creates a powerful connection between Modbus TCP/IP and EtherNet/IP networks. The module provides one Ethernet port. The Modbus TCP/IP driver supports Schneider Electric processors as well as most other devices that use Modbus TCP/IP. This implementation allows both Client (Master) and server (slave) configurations using standard Ethernet TCP/IP connections. The gateway can use both Modbus TCP/IP MBAP and Encapsulated Modbus message formats. The EtherNet/IP protocol supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a server, the EtherNet/IP port is a very powerful data transfer tool. General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone, DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols. s The Modbus TCP/IP driver allows multiple independent, concurrent Ethernet connections. The connections may be all Clients, all servers, or a combination of both Client and server connections. Modbus TCP/IP Client Actively reads data from and writes data to Modbus TCP/IP devices using MBAP One Client connection with multiple commands to talk to multiple servers Modbus TCP/IP Server The server driver accepts incoming connections on Service Port 502 for Clients using Modbus TCP/IP MBAP messages and connections on Service Port 2000 (or other Service Ports) for Clients using Encapsulated Modbus messages. Supports multiple independent server connections for any combination of Service Port 502 (MBAP) and Service Port 2000 (Encapsulated) Up to 20 Servers are supported

254 EtherNet/IP Server In server mode, the gateway accepts commands from one or more Clients to read/write data stored in the gateway s internal registers. Number of Connections 5 Supported PLC Types PLC2, PLC5, SLC and ControlLogix file types supported Internal Database Data Table File Size: 100 or 1000 words Data Table File Start: N10 to N109 (based on file size set to 100) or N10 to N19 (based on file set to 1000) CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client In Client mode, the gateway controls the read/write data transfer between the gateway and other EtherNet/IP devices. Number of Clients Supported 1 Command List Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. Polling of Command List User-configurable polling of commands, including disabled, continuous and on change of data (write only). Other Configurable Parameters Number of Commands (up to 100 per Client) Min Command Delay Response Timeout Retry Count Command Error Pointer Modbus TCP/IP Number of Clients Supported 1 Modbus Commands Supported (Client and Server) Configurable Parameters (Client and Server) Configurable Parameters (Client Only) Command List Status Data Command List Polling 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers Gateway IP Address Modbus data type starting address offsets Floating-point start address and database offset Minimum Command Delay Response Timeout Retry Count Command Error Pointer Up to 100 fully configurable Client commands Error codes reported individually for each command Each command can be individually enabled or disabled; write-only-on-data-change is available Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at: Ordering Information To order this product, please use the following: Modbus TCP/IP to EtherNet/IP Gateway 5201-MNET-DFNT To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to: and select Distributors from the menu. Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com Fax to Europe / Middle East / Africa europe@prosoft-technology.com Fax to +33 (0)

255 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions (Height x Width x Depth) LED Indicators (On all gateways) Configuration Serial Port Ethernet Port (Ethernet protocol gateways only) Application Serial Port(s) (Serial protocol gateways only) 24 Vdc nominal 18 Vdc to 32 Vdc allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma 32 Vdc maximum -4 F to 122 F (-20 C to 50 C) -40 F to 185 F (-40 C to 85 C) 5% to 95% RH with no condensation Standard: 5.20 in x 2.07 in x 4.52 in (13.2 cm x 5.25 cm x cm) Extended: 5.20 in x 2.73 in x 4.52 in (13.2 cm x cm x cm) Power and Hardware Fault Configuration and Application Communication Status Serial Configuration Port Activity and Error DB-9M RS-232 only No hardware handshaking 10 Base-T half-duplex RJ45 Connector Link LED and Activity LED indicators Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 DB-9 to Screw Terminal Adapter Note: The number of serial application ports depends on the gateway type, and the combination of protocols. Serial Port Isolation 2500 Vrms port signal isolation per UL Vdc min. isolation port to ground and port to logic Shipped WITH Each Unit Mini-DIN to DB-9M serial cables 4-foot RS-232 configuration cable 2.5 mm screwdriver CD (docs and configuration utility) RS-422/485 DB-9 to Screw Terminal Adapter for each serial application port (serial protocols only) Agency Approvals and Certifications ATEX CE culus CB Safety Where Automation Connects Global Distribution ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at: Global Support We are there for you All ProSoft Technology products are backed with free technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at: Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Copyright 2014 ProSoft Technology, Inc., All rights reserved. 4/23/2014 s subject to change without notice.

256 DH-485 to Modbus TCP/IP Gateway 5201-DH485-MNET The ProLinx DH-485 to Modbus TCP/IP Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a DH-485 device. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and one Ethernet port. DH-485 to Modbus TCP/IP Gateway 5201-DH485-MNET The DH-485-MNET modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a DH-485 device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.

257 DH485 Functioning as a Master Command List Polling of command list Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count User configurable polling of commands, including disabled, continuous and on change of data (write only) Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-DH485-MNET DH-485 to Modbus TCP/IP Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

258 Modbus TCP/IP to DNP 3.0 Master Gateway Modbus TCP/IP to DNP 3.0 Master Gateway 5201-MNET-DNPM The MNET-DNPM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate DNP Master devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the DNP 3.0 Master device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English 5201-MNET-DNPM The ProLinx Modbus TCP/IP to DNP 3.0 Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and DNP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

259 DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) DNP Master Node address Slave count Command count 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-DNPM Modbus TCP/IP to DNP 3.0 Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

260 Modbus TCP/IP to DNP 3.0 Slave Gateway Modbus TCP/IP to DNP 3.0 Slave Gateway 5201-MNET-DNPS The MNET-DNPS modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate DNP Slave devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Modbus Processors (Modicon and many others). In combination with the DNP 3.0 Slave device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201-MNET-DNPS The ProLinx Modbus TCP/IP to DNP 3.0 Slave Gateway creates a powerful connection between devices on a Modbus network and DNP master devices. This standalone DIN-rail mounted protocol gateway provides one Ethernet port and one serial port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

261 DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-DNPS Modbus TCP/IP to DNP 3.0 Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

262 Modbus TCP/IP to DNP 3.0 over Ethernet Gateway Modbus TCP/IP to DNP 3.0 over Ethernet Gateway 5201-MNET-DNPSNET The MNET-DNPSNET modules are the ideal solution for joining Modbus TCP/IP and DNP over Ethernet networks. This Ethernet to Ethernet gateway is a powerful module designed with both Client and Server support for each protocol, enabling easy connections between the dissimilar network types. The module utilizes a shared database so that the two protocols can quickly and easily transfer data between themselves. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201-MNET-DNPSNET The ProLinx Modbus TCP/IP to DNP over Ethernet Gateway creates a powerful connection between devices on Modbus TCP/IP and DNP over Ethernet networks. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The ProLinx module supports the DNP 3.0 protocol as a server using the TCP and UDP protocols using service port This port is fully configurable. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

263 DNP 3.0 over Ethernet The DNP 3.0 over Ethernet driver provides support as a server using the TCP and UDP protocols using service port General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 125 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Server Level 2 DNP Server Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in (13.2H x 5.25W x 11.48D cm) Extended: 5.20H x 2.73W x 4.52D in (13.2H x 6.934W x 11.48D cm) Ethernet Port (Ethernet modules only) Shipped with Each Unit RJ45 Connector Link and Activity LED indicators Mini-DIN to DB-9M serial cable 4 ft RS-232 configuration cable 2.5 mm screwdriver ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our website at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-DNPSNET Modbus TCP/IP to DNP 3.0 over Ethernet Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific info@prosoft-technology.com fax to Europe europe@prosoft-technology.com fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. August 11, 2017 LED Indicators Configuration Serial Port Power and Module Status Application Status DB-9M RS-232 only No hardware handshaking

264 Modbus TCP/IP to GE Ethernet Global Data Gateway Modbus TCP/IP to GE Ethernet Global Data Gateway 5201-MNET-EGD The MNET-EGD modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate GE Ethernet Global Data devices into a system. The Modbus TCP/IP driver is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the GE Ethernet Global Data device support, the module provides a powerful interface to the many Modbus TCP/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5201 MNET-EGD The ProLinx Modbus TCP/IP to GE Ethernet Global Data Gateway creates a powerful connection between Modbus TCP/IP and GE Ethernet Global Data networks. The module provides one Ethernet port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections. The EGD modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database. This common database provides the "backbone" communications for various field devices using different networks. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

265 EGD GE Ethernet Global Data (EGD) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Bandwidth utilization is optimized by using efficient communication methods. High reliability means fewer communication failures and having the ability to detect failures upon occurrence. Particular emphasis is delivered for applications requiring periodic or frequent updates and time synchronization of devices. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the network can produce these types of messages and each device determines which of these messages to consume. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation Shipped with Each Unit 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-EGD Modbus TCP/IP to GE Ethernet Global Data Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. April 29, 2014

266 Modbus TCP/IP to HART Multi-drop Gateway Modbus TCP/IP to HART Multi-drop Gateway 5207 MNET-HART The MNET-HART modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate HART Multi-drop devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the more than two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5207-MNET-HART The ProLinx Modbus TCP/IP to HART Multi-drop Gateway creates a powerful connection between devices on an EtherNet/IP network and HART Multi-drop devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and four configurable HART channels. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

267 HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Configurable Parameters per Channel HART Driver Command List Polling of command list Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5207 MNET-HART Modbus TCP/IP to HART Multi-drop Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

268 DATASHEET Modbus TCP/IP to HART Analog Gateway 5208-MNET-HART / 5228-MNET-HART Modbus TCP/IP to HART Analog Gateway 5208-MNET-HART / 5228-MNET-HART The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a Modbus TCP/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port HART Analog The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the

269 use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Configurable Parameters per Channel HART Driver Command List Polling of command list Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. Isolated HART Analog Input s Input Range Current: 4 to 20mA with HART Resolution 16bits Input Filter First Order Sync: 10 Hz Current Input Resistance ohms +/- 1% Open circuit detection 1/2 second maximum time Over current +/-40mA continuous, maximum Common Mode Noise 105dB Rejection Calibrated 4 to 20 ma: 0.05% of reading 25 C Input Isolation Voltage 2500 V RMS per UL 1577, transformer isolated 24V DC Isolation Voltage 1500 VDC HART is a registered trademark of the HART Communication Foundation Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Input 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade Current Load 1-4 ch: 190 ma max@ 32 VDC max 5-8 ch: 250 ma max@ 32 VDC max Operating -20 to 50 C (-4 to 122 F) Temperature Storage -40 to 85 C (-40 to 185 F) Temperature Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Power and Module Status Application Status HART Channel Activity (Green) Configuration Serial Port HART Interface DB-9M RS-232 only No hardware handshaking Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs) Screw terminals for each channel Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Common Mode DC Rejection Over current +/- 40mA continuous, maximum Overvoltage Protection All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection Accuracy 4 to 20 ma: 0.05% of 25 C 24VDC loop output power Shipped with Each Unit Certifications MTBF 5-Year Performance Probability 1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector CE and ATEX 937,320 Hours 95.43%

270 Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Compatible products in this product line also include: EtherNet/IP to HART Analog Gateway (5208-DFNT-HART / 5228-DFNT-HART) DF1Master/Slave to HARTAnalog Gateway (5108-DFCM-HART / 5128-DFCM-HART) Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5208-MNET-HART / 5228-MNET-HART Modbus TCP/IP to HART Analog Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) s are subject to change without notice. Copyright ProSoft Technology, Inc All Rights Reserved. 2/25/15

271 Modbus TCP/IP to Modbus Master/Slave Gateway 5201/5202-MNET-MCM(4) The MNET-MCM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate Modbus Master/Slave serial devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP Devices (Modicon processors and many others). In combination with the Modbus Master/Slave device support, the module provides a very powerful interface to the many Modbus Master/Slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus TCP/IP to Modbus Master/Slave Gateway 5201/5202-MNET-MCM(4) The ProLinx Modbus TCP/IP to Modbus Master/Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Modbus serial devices. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and up to four serial ports. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

272 General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNET-MCM 5202-MNET-MCM4 Modbus TCP/IP to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

273 Modbus TCP/IP to PROFIBUS DP Master Gateway Modbus TCP/IP to PROFIBUS DP Master Gateway 5204-MNET-PDPM The MNET-PDPM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5204-MNET-PDPM The ProLinx Modbus TCP/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB-9F port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

274 PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5204-MNET-PDPM Modbus TCP/IP to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

275 Modbus TCP/IP to PROFIBUS DPV1 Master Gateway 5204-MNET-PDPMV1 The MNET-PDPM modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus TCP/IP to PROFIBUS DPV1 Master Gateway 5204-MNET-PDPMV1 The ProLinx Modbus TCP/IP to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and PROFIBUS DP Master configurable DB-9F port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC on either a Mono-Master or Multi- Master network. The module supports the DPV1 specification. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Module IP Address Modbus address offsetting Modbus TCP/IP Client General Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Configurable parameters Command List Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port PROFIBUS DP Master V1 The module supports complete Master specifications according to IEC Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol. The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network. Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB) Project-unique GSD file import library Monitoring and Modification of process data and DPV1 acyclic data Multi-drop on a PROFIBUS DPV1 network drop with other compatible devices

276 Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network Automatic project documentation Automatic Bus Parameter calculation Online slave diagnostics Supports all standardized baud rates, up to 12Mbps Supports extended diagnostic data (DPV1) Auto baud detection at all valid PROFIBUS DPV1 rates Multiple modules can be placed in a single rack CRC checksum determination of slave configuration consistency to processor Master Status LED Indicators for Operations, Network Drop Communication, Master Token-Hold FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM) PROFIBUS Master s Up to 125 Slaves can be connected with a repeater Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words) output data Supports Extended Diagnostic Data RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter Acyclic communications (DPV1), Read and Write Alarm Handling (DPV1) Supports Sync and Freeze commands Supports PROFIdrive 3.1 compliant parameter read and write operations Supports Multicast and Broadcast telegrams (DPV1) PROFIBUS Master Port DB-9F Optically Isolated RS-485 Ready, Run, Error and Token LED Indicators PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female connector and isolated Opto-Couplers General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5204-MNET-PDPMV1 Modbus TCP/IP to PROFIBUS DPV1 Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. February 29, 2008

277 Modbus TCP/IP to PROFIBUS DP Slave Gateway Modbus TCP/IP to PROFIBUS DP Slave Gateway 5205-MNET-PDPS The MNET-PDPS modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the PROFIBUS DP device support, the module provides a very powerful interface to the many Modbus TCP/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5205-MNET-PDPS The ProLinx Modbus TCP/IP to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS DP Master device. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port and a single DB9F PROFIBUS port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

278 PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site PROFIBUS s Communication Baud Rate: 9.6 kbit/s 12 Mbit/s parameters Supported I/O length 244 bytes Input data 244 bytes Output data 400 bytes total Supported PROFIBUS DP features Configurable Parameters PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5205-MNET-PDPS Modbus TCP/IP to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

279 Modbus TCP/IP to Rockwell Automation Remote I/O Gateway Modbus TCP/IP to Rockwell Automation Remote I/O Gateway 5210-MNET-RIO The MNET-RIO modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Remote I/O device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5210-MNET-RIO The ProLinx Modbus TCP/IP to Rockwell Automation Remote I/O Adapter Gateway creates a powerful connection between devices on a Modbus TCP/IP network and Remote I/O devices. This stand-alone DINrail mounted protocol gateway provides one Ethernet port and one Remote I/O port. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port

280 Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5210-MNET-RIO Modbus TCP/IP to Rockwell Automation Remote I/O Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

281 DISCONTINUED Modbus TCP/IP to Siemens 3964R Protocol Gateway 5202-MNET-S3964R4 The ProLinx Modbus TCP/IP to Siemens 3964R Gateway allows point-to-point communication between a Modbus TCP/IP Ethernet network and 3964R serial communication partners. The Modbus TCP/IP protocol driver supports Schneider Electric processors as well most other devices that use Modbus TCP/IP for communicating over Ethernet networks. The gateway offers both Client (Master) and Server (Slave) configurations that use standard Ethernet TCP/IP connections and recognize both Modbus TCP/IP MBAP and Encapsulated Modbus messages. The Modbus TCP/IP implementation on this gateway has been specially developed to provide tight integration with 3964R protocol requirements. The 3964R protocol was designed by Siemens for bi-directional data communication. It provides a point-to-point, serial interface connection that supports assigning high-priority or low-priority read and write access to each communication partner. This reduces initialization errors and improves data messages, increasing its versatility and range of possible applications. Features Benefits Powerful network integration Communicate between dissimilar networks Shared database exchanges information from devices on both networks View diagnostics between both networks Modbus TCP/IP protocol interface Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols Suitable for SCADA and 'foreign device' interface applications S3964R Protocol Interface (on four serial ports) Floating point data movement supported, including configurable support for Enron and Daniel floating point applications Communicate with programmable controllers, intelligent devices, sensors and instruments Allows PCs and HMIs to monitor field devices Integrates with Schneider Electric baggage-handling projects using Siemens 3964R protocol Bi-directional data communication with communication partner high/low priority assignment Support simultaneous connections to as many as four 3964R communication partners Shares common database with Modbus TCP/IP network Backed by ProSoft Technology 20-year history of delivering high-quality, reliable solutions designed with you in mind Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer Three-Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrated with our hardware...a simple and quick, total solution to help you make our products fit your applications Configuration ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. The 5202-MNET-S3964R4 Setup Guide and sample configuration provide an quick and easy example with step-by-step instructions on how to move data from one network to the other.

282 General s ProLinx Communication Gateways provide connectivity for two or more dissimilar network types. The gateways, encased in sturdy extruded aluminum, are stand-alone DIN-rail-mounted solutions that provide data transfer between many of today s most widely used industrial automation. Modbus TCP/IP ProSoft's Modbus TCP/IP implementation uses the gateway's shared internal memory database for data transfer. Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP/IP devices and other devices on other networks. Schematic Configurable floating point data movement is supported, including support for Enron or Daniel floating point applications. Modbus TCP/IP Server (Slave) The server driver accepts incoming connections on Service Port 502 for clients using Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or other Service Ports) for clients using Encapsulated Modbus messages.. Supports five independent server connections for Service Port 502 (MBAP) Supports five independent server connections for Service Port 2000 (Encapsulated) The Modbus TCP/IP implementation in this gateway has been specially designated to meet the unique requirements of the 3964R protocol. This provides a more tightly integrated solution for data transfer between the two protocols. Modbus data types overlap in the gateway's memory database, so the same data can be conveniently read or written as bit-level or register-level data. Modbus TCP/IP Client (Master) Actively reads data from and writes data to Modbus TCP/IP devices, using MBAP or Encapsulated Modbus message formats Offers one client connection with up to 100 commands to talk to multiple severs Status Data Error codes, counters, and port status available S3964R Supported baud rates: 600 through are typical; up to is possible Supported protocols: 3964 with RK512, 3964 without RK512 Priority setting to define the behavior of the protocol in case of an initialization conflict. Offers four independently configurable serial ports. Each port can communicate using 3964R protocol with or without RK512 formatting. Each port can be set to use an RS-232 or RS-422 serial signal interface. The ports operate independently from each other and each port is assigned its own space in the gateway's user memory database. When using S3964R without RK512 communications mode, Port 0, Port 1, Port 2, and Port 3 can initiate or receive DB-SEND instructions. RK512 mode on Port 0, Port 1, Port 2, and Port 3 allow evaluation of RK512 header information: DB data block, DW data word, Coordination Byte 9, and CPU Coordination Byte 10. When using S3964R without RK512 communications mode, Port 0, Port 1, Port 2, and Port 3 can send or receive standard communication telegrams (message packets). In either mode, 512 bytes is the maximum amount of data transferred per data transfer operation Data byte order can be swapped to support different device-specific word formats Communication activity indications and diagnostic information are available through LEDs and acknowledgment telegrams.

283 Functional s - Modbus TCP/IP Modbus Commands Supported (Client and Server) Configurable Parameters: (Client and Server) Configurable Parameters: Client Command List Status Data Polling of command list 1 : Read Coils Status 2 : Read Input Status 3 : Read Holding Registers 4 : Read Input Registers 5 : Force (Write) Single Coil 6 : Preset (Write) Single Holding Register 15 : Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers Gateway IP Address Modbus data type starting address offsets Floating point start address and database offset Minimum Command Delay Response Timeout Retry Count Command Error Pointer Up to 100 fully-configurable Client commands Error codes reported individually for each command Each command can be individually enabled or disabled; write-only-on-data-change is available Functional s - S3964R Ports Baud rates Parity 4 independent RS-232/422 serial application ports Typical: 600, 1200, 2400, 4800, 9600, bps (available on all four ports) Additional Possible: 38400, 57600, bps (available only on Port 1, Port 2, and Port 3) Even, odd, None Where Automation Connects Global Distribution We think like you do ProSoft Technology products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries. Our knowledgeable distributors are familiar with your application needs. For a complete list of distributors, go to our web site at Global Support We are there for you All ProSoft Technology products are backed with free, unlimited technical support. Contact our worldwide Technical Support team directly by phone or . Global Offices We are where you are ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at com. Whether your application is large or small, our technical professionals are there to help you choose the right communication solution. Data bits 8 Stop bits 1 Maximum distance RS cable meters RS cable meters Maximum Data Transfer 512 bytes per data transfer operation

284 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port Application Serial Ports 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma 32 VDC max -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and General Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Mini DIN8 RS-232 only (Mini-DIN8/DB9M adapter included) No hardware handshaking 10Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Serial Port Isolation 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Shipped with Each Unit Mini-DIN to DB-9M serial cable adapters 4 ft RS-232 null-modem DB9F configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor Agency Approval & Certification ISA ISA Class 1 Div 2 CSA/cUL C22.2 No Copyright ProSoft Technology, Inc All Rights Reserved. December 29, 2013 s subject to change without notice

285 Modbus TCP/IP Multi Client to EtherNet/IP Gateway 5201-MNETC-DFNT The MNETC-DFNT modules are the ideal solution for the many applications where Modbus TCP/IP Client connectivity can be used to integrate EtherNet/IP devices into a system. The Modbus TCP/IP gateway is a powerful module designed with up to five Clients, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the EtherNet/IP device support, the module provides a very powerful interface to the many EtherNet/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Modbus TCP/IP Multi Client to EtherNet/IP Gateway 5201-MNETC-DFNT The ProLinx Modbus TCP/IP Multi Client to EtherNet/IP Gateway creates a powerful connection between Modbus TCP/IP and EtherNet/IP networks. The module provides one Ethernet port. The Modbus TCP/IP Multi Client protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNETC driver supports up to ten Client connections, and when coupled with the Web option provides a web/ftp interface as well. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. Modbus TCP/IP Multi Client The Modbus TCP/IP Multi Client driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP Client and other networks and devices. Modbus TCP/IP Multi Client General Configurable parameters Command List Actively reads and writes data with Modbus TCP/IP compatible devices. The MNET driver supports 5 MNET Modbus TCP/IP servers (port 2000) 5 MBAP Modbus TCP/IP servers (port 502) 10 Modbus TCP/IP clients (MNET or MBAP), each supporting up to 16 Modbus TCP/IP commands. The Ethernet driver interfaces with a common internal database in the module. This permits the sharing of data across many different protocols and networks. Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 16 fully configurable commands on the Client port EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported

286 EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Data File CIP Services Supported Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data Table File Start Fixed at N10 Data Table File Size 100 or 1000 words 0x4C CIP Data Table Read 0x4D CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only). General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 32 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5201-MNETC-DFNT Modbus TCP/IP Multi Client to EtherNet/IP Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. September 27, 2007

287 PROFIBUS DP Slave to Honeywell DE Master Gateway 5306-PDPS-DEM The PDPS-DEM modules are the ideal solution for the many applications where PROFIBUS DP connectivity can be used to integrate Honeywell DE slave devices into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to PROFIBUS master devices. In combination with the Honeywell DE support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English DISCONTINUED PROFIBUS DP Slave to Honeywell DE Master Gateway 5506-PDPS-DEM The ProLinx PROFIBUS DP Slave to Honeywell DEM Gateway creates a powerful connection between devices on a PROFIBUS DP network and Honeywell DE slave device. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and eight configurable Honeywell DE channels. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PRLX05A5.GSD Downloadable from ProSoft Technology web site Europe Middle East Africa PROFIBUS s +33 (0) , support.emea@prosoft- Communication Baud Rate: 9.6 kbit/s 12 Mbit/s technology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English parameters Supported I/O length Supported PROFIBUS DP features 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Latin America (Sales only) , latinam@prosoft-technology.com Auto Baud Setting Languages spoken include: Spanish, English Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database

288 Honeywell DE Master Configuration Serial The ProLinx DEM Protocol Driver is designed to Port interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the Ethernet Port (Ethernet internal database contained in the DEM module. modules only) DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power LEDs for Visual Module Status DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 13, 2013

289 PROFIBUS DP Slave to HART Multi-drop Gateway 5507-PDPS-HART The PDPS-HART modules are the ideal solution for the many applications where PROFIBUS DP connectivity can be used to integrate HART Multi-drop devices into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to PROFIBUS master devices. In combination with the HART support, the module provides a very powerful interface to the more than two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English PROFIBUS DP Slave to HART Multi-drop Gateway 5507-PDPS-HART The ProLinx PROFIBUS DP Slave to HART Multi-drop Gateway creates a powerful connection between devices on a PROFIBUS DP network and HART field devices. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and 4 configurable HART Multi-drop channels. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART

290 channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Configurable Parameters per Channel HART Driver Command List Polling of command list Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5507-PDPS-HART PROFIBUS DP Slave to HART Multi-drop Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

291 PROFIBUS DPV1 Master FDT Communications DTM PSW-cDTM-PDPM FDT (Field Device Tool) technology standardizes the communication interface between field devices and systems. The key feature is its independence from the communication protocol and the software environment of either the device or the host system. FDT allows any device to be accessed from any host through any protocol. PROFIBUS DPV1 Master PSW-cDTM-PDPM The PROFIBUS DPV1 Master FDT (Field Device Tool) communication DTM (comdtm) software is an interface between any compliant FDT software container, an FDT device DTM and applicable PROFIBUS slave devices. The FDT PROFIBUS comdtm and a compatible FDT frame application connect multiple device DTMs to their respective PROFIBUS connected field instruments using the Ethernet port on the PC and PROFIBUS DPV1 master module. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Typical FDT frame applications are Fieldcare (Endress + Hauser), PACTware (PACTware association) or fdtcontainer (MM-Software). The PROFIBUS DPV1 master modules support Class 1 and 2 services thereby allowing for PLC cyclic Class 1 services to co-exist with acyclic comdtm Class 2 services over the same network. General s General specifications for comdtm software include: Support for PTQ-PDPMV1 Ethernet port (no serial connectivity) Support for MVI56-PDPMV1 COM 2 serial port (no Ethernet connectivity, use Serial to Ethernet converter) FDT compatible Official FDT-JIG certificate PROFIBUS-DPV1 master Class II operation (acyclic master/slave services)

292 PROFIBUS DPV1 Class II Services: o Initiate o Read o Write o Data transport o Abort Can be used to access Slaves concurrently as the master is scanning (Class I) the network I/O for the PLC. Supports many FDT containers such as FieldCare and PACTware. Built-in Ethernet and serial transport communication providers Software license provides full support of all configured device DTMs and communication of up to 15 master modules. Additional Functions performed: o Scan list function o Set Slave address System Requirements A ProSoft Technology PROFIBUS DPV1 Master module with available user Ethernet or Serial port. FDT v1.2.1 Frame program such as FieldCare or PACTware. Hardware Requirements (Recommended) o Pentium 4 with 2 GHz Processor, 256 MB RAM o 450 MB disk space (for DTM Libraries) o Monitor 1024 X 768, 64k colors Software Requirements (Minimum) o Windows NT 4.0 Service Pack 6A, Windows 2000 SP3 or Windows XP o Microsoft Internet Explorer Version 6.0 o Microsoft Management Console* o Adobe Acrobat Reader 5.0* *Some FDT Containers require these components Additional Products ProSoft Technology offers a full complement of PROFIBUS DPV1 Master/Slave communication solutions for a variety of ProLinx Communication Gateways and PLC processor platforms: PTQ-PDPMV1 MVI56-PDPMV1 PCB ProLinx Gateways ProTalk PROFIBUS DPV1 Master inrax ControlLogix PROFIBUS DPV1 Master ProSoft Configuration Builder. Software required to configure all PROFIBUS DPV1 Masters and slaves. Please visit our WEB site for listing of these products. Visit our web site or contact the factory for a complete and up-to-date list of available ProSoft Technology products. Ordering Information To order this product, please use the following: PSW-cDTM-PDPM PROFIBUS DPV1 Master FDT Communications DTM To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. April 26, 2007

293 Rockwell Automation Remote I/O to IEC Slave Gateway Rockwell Automation Remote I/O to IEC Slave Gateway 5601-RIO-101S The RIO-101S modules are the ideal solution for the many applications where IEC 101 Slave connectivity can be used to integrate a Remote I/O master device into a system. The IEC Slave gateway is a powerful module designed with Slave support, enabling easy connection to IEC 101 master devices. In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5601-RIO-101S The ProLinx Rockwell Automation Remote I/O Adapter to IEC Slave Gateway creates a powerful connection between devices on an IEC 101 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and one IEC 101 Slave configurable serial port. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The IEC Slave protocol driver supports Slave implementations of the protocol. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

294 IEC Slave The 101S module acts as an input/output module between the IEC and other protocols and networks, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Storage of IEC time used in module is available in the database Protocol implementation conforms to the IEC specification with fully configurable parameters Priority Queues Invalid Bit Monitoring Supports Balanced and Unbalanced Mode Supports CP24 and CP56 time formats for events Event generation configurable per point or data type General Parameters Communication parameters IEC Slave Configurable Parameters Baud Rate: 110 to 19,200 baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing Delays: 0 to ms Data link address length Common Address of ASDU length Inform. Object Address length Select/Operate Timeout Event Scan delay Use Balanced Mode Short Pulse Time Long Pulse Time Time DB Offset General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-101S Rockwell Automation Remote I/O to IEC Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

295 Rockwell Automation Remote I/O to IEC Master Gateway Rockwell Automation Remote I/O to IEC Master Gateway 5601-RIO-103M The RIO-103M modules are the ideal solution for the many applications where IEC 103 Master connectivity can be used to integrate a Remote I/O master or slave device into a system. The IEC Master gateway is a powerful module designed with Master support, enabling easy connection to other IEC 103 devices. In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O master or slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5601-RIO-103M The ProLinx Rockwell Automation Remote I/O Adapter to IEC Master Gateway creates a powerful connection between devices on an IEC 103 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and one IEC 103 Master configurable serial port. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The IEC Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is user-configurable, providing a very powerful and flexible host or device interface solution. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

296 IEC Master The IEC Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc). The module supports: 16 slaves (sessions with distinct Data Link Addresses) Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses) Configurable Time Sync and General Interrogation messages during initialization Supports General Interrogation, General Command and Time Synchronization Commands. General Parameters Communication parameters IEC Master Configurable Parameters Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 5 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Baud Rate Parity RTS On RTS Off Minimum Delay Receive Timeout Data Link Address Common ASDU Address General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-103M Rockwell Automation Remote I/O to IEC Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

297 Rockwell Automation Remote I/O to ASCII Generic Serial Gateway 5601/5602-RIO-ASCII(4) The RIO-ASCII modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate ASCII serial input devices into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English DISCONTINUED Rockwell Automation Remote I/O to ASCII Generic Serial Gateway 5601/5602-RIO-ASCII(4) The ProLinx Rockwell Automation Remote I/O to ASCII Generic Serial Gateway creates a powerful connection between devices on a Remote I/O network and ASCII input devices. The module provides one Remote I/O port and up to four ASCII configurable serial ports. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

298 ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Transmit and Receive buffer size Transmit character with pacing Available in up to four port configurations to receive and/or transmit data. 255 bytes each 0 to millisecond delay between each transmitted character. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December18, 2013

299 Rockwell Automation Remote I/O to Honeywell DE Master Gateway 5606-RIO-DEM The RIO-DEM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate Honeywell DE devices into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Honeywell DE Master support, the module provides a very powerful interface to the many Honeywell DE slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Rockwell Automation Remote I/O to Honeywell DE Master Gateway 5606-RIO-DEM The ProLinx Rockwell Automation Remote I/O Adapter to Honeywell DE Master Gateway creates a powerful connection between devices on a Remote I/O network and Honeywell DE slave devices. This stand-alone DINrail mounted protocol gateway provides one Remote I/O port and eight Honeywell DE Master channels. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The DEM protocol driver is designed to provide a tightly integrated communications interface between other protocols of the ProLinx platform and the Honeywell DE instruments. Compatible DE devices include a large array of field devices including pressure, temperature, metering, and many other instruments. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

300 Honeywell DE Master The ProLinx DEM Protocol Driver is designed to interface with up to 8 DE devices. Data is exchanged between the DE instruments and the driver using the internal database contained in the DEM module. DE Communications Built in accordance with the Honeywell DE specification Supports up to 8 single PV transmitters, 2 multivariable transmitters with 4 PVs each, or a mix of single and multivariable equaling 8 input channels Instrument database mismatch verification Interfaces directly to Honeywell Field Terminal Assembly (FTA) with ProSoft-supplied cable Supports redundant and non-redundant FTA implementations Single cable connection from DEM module to FTA Physical s Power Source External 24 VDC source connection on the front of the DEM module provides instrument loop power LEDs for Visual Module Status DE Active DE Error General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5606-RIO-DEM Rockwell Automation Remote I/O to Honeywell DE Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

301 Rockwell Automation Remote I/O to DF1 Master/Slave Gateway 5601/5602-RIO-DFCM(4) The RIO-DFCM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate DF1 Master/Slave devices into a system. The Remote I/O gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DF1 device support, the module provides a very powerful interface to the many DF1 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Rockwell Automation Remote I/O to DF1 Master/Slave Gateway 5601/5602-RIO-DFCM(4) The ProLinx Rockwell Automation Remote I/O Adapter to DF1 Master/Slave Gateway creates a powerful connection between devices on a Remote I/O network and DF1 devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and up to four serial ports. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).

302 General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking Miscellaneous BCC and CRC Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-DFCM 5602-RIO-DFCM4 Rockwell Automation Remote I/O to DF1 Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

303 Rockwell Automation Remote I/O to DH-485 Gateway 5601-RIO-DH485 The RIO-DH485 modules are the ideal solution for the many applications where DH-485 connectivity can be used to integrate Remote I/O devices into a system. The DH-485 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Rockwell Automation Remote I/O to DH-485 Gateway 5601-RIO-DH485 The ProLinx Rockwell Automation Remote I/O Adapter to DH-485 Gateway creates a powerful connection between devices on DH-485 and Remote I/O networks. This stand-alone DIN-rail mounted protocol gateway provides one DH-485 configurable serial port and Remote I/O port. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The DH-485 protocol driver supports the Master and the Slave modes of the protocol on each port, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. All DH-485 ports are individually configurable. User configurable data mapping make the interface an easy to use and powerful data transfer tool. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

304 DH-485 The DH-485 protocol in its native form is a peer to peer token passing network. The ProLinx DH-485 driver accesses the network functioning either as a Master or as a Slave. General Protocol Information Error Checking BCC and CRC Communication Parameters Local Station ID: 0 to 31 Port 0 Baud Rate: 110 to 38.4K baud Port 1 Baud Rate: 110 to baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms DH-485 Slave Mode In Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH-485 commands and has the appearance of an SLC processor to the network. DH-485 Master Mode In Master mode, the ProLinx DH-485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH-485 devices, such as SLC processors. Data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware. DH485 Functioning as a Master Command List Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-DH485 Rockwell Automation Remote I/O to DH-485 Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

305 Rockwell Automation Remote I/O to DNP 3.0 Master Gateway Rockwell Automation Remote I/O to DNP 3.0 Master Gateway 5601-RIO-DNPM The RIO-DNPM modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate Remote I/O serial devices into a system. The DNP Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5601-RIO-DNPM The ProLinx Rockwell Automation Remote I/O Adapter to DNP 3.0 Master Gateway creates a powerful connection between devices on a DNP 3.0 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one RIO port. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

306 DNP 3.0 Master The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc). General Parameters Internal Database Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points DNP Mode DNP 3.0 Master Level 2 DNP Object Support DNPM Driver Manual contains full Object Definition documentation DNP Master Node address Slave count Command count 0 to software selectable Up to 40 slave devices Up to 300 user defined commands to interface with remote slave devices General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-DNPM Rockwell Automation Remote I/O to DNP 3.0 Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

307 Rockwell Automation Remote I/O to DNP 3.0 Slave Gateway 5601-RIO-DNPS The ProLinx Rockwell Automation Remote I/O Adapter to DNP 3.0 Slave Gateway creates a powerful connection between devices on a Remote I/O network and DNP devices. This stand-alone DIN-rail mounted protocol gateway provides one configurable serial port and one RIO port. Rockwell Automation Remote I/O to DNP 3.0 Slave Gateway 5601-RIO-DNPS The RIO-DNPS modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate DNP serial devices into a system. The RIO gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the DNP device support, the module provides a very powerful interface to the many DNP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

308 DNP 3.0 Slave The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc). General Parameters Internal Database Communication parameters Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to ms DNP Mode DNP 3.0 Slave Level 2 DNP Slave Node address 0 to (software selectable) General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-DNPS Rockwell Automation Remote I/O to DNP 3.0 Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

309 Rockwell Automation Remote I/O to HART Multi-drop Gateway 5607-RIO-HART The RIO-HART modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate HART Multi-drop devices into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Rockwell Automation Remote I/O to HART Multi-drop Gateway 5607-RIO-HART The ProLinx Rockwell Automation Remote I/O Adapter to HART Multi-drop Gateway creates a powerful connection between devices on a Remote I/O network and HART devices. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and four configurable HART Multi-drop channels. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

310 HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Configurable Parameters per Channel HART Driver Command List Polling of command list Primary Master: Y or N Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 18, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

311 Rockwell Automation Remote I/O to Modbus Master/Slave Gateway 5601/5602-RIO-MCM(4) The RIO-MCM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate Modbus devices into a system. The Remote I/O gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Rockwell Automation Remote I/O to Modbus Master/Slave Gateway 5601/5602-RIO-MCM(4) The ProLinx Rockwell Automation Remote I/O Adapter to Modbus Master/Slave Gateway creates a powerful connection between devices on a Remote I/O network and Modbus devices. This standalone DIN-rail mounted protocol gateway provides one Remote I/O port and up to four serial ports. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

312 General Parameters Modbus Protocol Communication parameters Error Checking Floating Point Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address Baud Rate: 110 to 115K baud Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating point data movement supported, including configurable support for Enron implementation 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5601-RIO-MCM 5602-RIO-MCM4 Rockwell Automation Remote I/O to Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

313 Rockwell Automation Remote I/O to PROFIBUS DP Master Gateway Rockwell Automation Remote I/O to PROFIBUS DP Master Gateway 5604-RIO-PDPM The RIO-PDPM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English 5604-RIO-PDPM The ProLinx Rockwell Automation Remote I/O Adapter to PROFIBUS DP Master Gateway creates a powerful connection between devices on a Remote I/O network and a PROFIBUS slave device. This stand-alone DINrail mounted protocol gateway provides one Remote I/O port and PROFIBUS DP Master configurable DB9F port. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The PROFIBUS DP Master protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number 0 to 63 Addressing Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector

314 PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port (Ethernet modules only) 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators Application Serial Ports Serial Port Isolation Shipped with Each Unit RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5604-RIO-PDPM Rockwell Automation Remote I/O to PROFIBUS DP Master Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

315 DATASHEET Rockwell Automation Remote I/O to PROFIBUS DP-V1 Master Gateway 5604-RIO-PDPMV1 The ProLinx family Allen Bradley Remote I/O Adapter to PROFIBUS DPV1 Master communications module (5604-RIO-PDPMV1) creates a powerful connection between devices on a Remote I/O network and PROFIBUS slave devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Remote I/O port and a PROFIBUS DPV1 Master with a RS pin D shell female connector interface with isolated Opto-Couplers. The RIO interface is an adapter (slave) which can be connected to a RIO scanner (master) that controls the data transfer. The PROFIBUS DPV1 Master (PDPMV1) protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network. The DPV1 master supports FDT/DTM communication when using the PSW-cDTM- PDPM FDT communication DTM. The PROFIBUS DPV1 Master FDT communication DTM software is an interface between any compliant FDT software container, an FDT device DTM and applicable PROFIBUS slave devices. The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in the industrial automation today. Features Unique PROFIBUS DPV1 to A-B RIO standalone solution FDT communication DTM compliant Supported by ProSoft Configuration Software (PCB) Three Year Warranty Benefits Enhances existing A-B RIO networks in support distributed or remote PROFIBUS DPV1 I/O devices Allows FDT Asset Management users to connect to field devices through Ethernet communications Supported by ProSoft Configuration Software (PCB) Low risk investment with great cost savings, backed up by a better than average equipment failure protection plan, from the industrial communications experts who know protocols, devices, and automation Configuration ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.

316 General s Allows for legacy in-chassis PROFIBUS DPV1 master applications to migrate to and/or sustain support for Allen-Bradley 1771 Remote I/O. ProSoft Configuration Builder (PCB) software with easy-to-use PROFIBUS master network and gateway configuration. Sample PCB configuration file included. The gateway provides an Ethernet port and supports FDT/DTM Ethernet communications using the included communication DTM for use with FDT compliant software containers. The RIO gateway enables the migration of distributed PROFIBUS I/O without impacting existing Allen-Bradley Remote I/O networks. 24VDC Power supply for current loops is included PLC 5 Sample ladder logic provided Sample PCB configuration file included Schematic Functional s Remote I/O Rack Number Addressing: 0 to 63 Rack Size: ¼-rack, ½-rack, ¾-rack and full rack Starting Group: 0, 2, 4, 6 Last Rack: Yes or No Baud Rate: 57.6K, 115K, 230K Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTR Command - up to 63 words BTW Command - up to 64 words PROFIBUS DPV1 Easy-to-use drag and drop Master Busview configuration interface via ProSoft Configuration Builder software Project-unique GSD file import library Monitoring and Modification of process data and DPV1 acyclic data Multi-drop on a PROFIBUS DPV1 network with other compatible devices Automatic project documentation Automatic Bus Parameter calculation Online slave diagnostics Supports all standardized baud rates, up to 12Mbps Supports extended diagnostic data (DPV1) Auto baud detection at all valid PROFIBUS DPV1 rates CRC checksum determination of slave configuration consistency to processor Master Status LED Indicators for Operations, Network Communication, Master Token-Hold and Network Configuration. FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM) Up to 125 Slaves can be connected with a repeater Up to 1536 cyclic bytes input and 1536 bytes output data Supports Extended Diagnostic Data RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter Acyclic communications (DPV1), Read and Write Alarm Handling (DPV1) Supports Sync and Freeze commands Supports PROFIdrive 3.1 compliant parameter read and write operations Supports Multicast and Broadcast telegrams (DPV1)

317 Hardware s Power Supply Current Load Operating Temperature 24 VDC nominal VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 32 VDC max -20 to 50 Deg C -4 to 122 Deg F Storage Temperature -40 to 85 Deg C -40 to 185 Deg F Relative Humidity 5-95% (w/o condensation) Dimensions LED Indicators Configuration Serial Port Standard 5.20H x 2.07W x 4.52D inches 13.2cmH x 5.25cmW x 11.48cmD Extended 5.20H x 2.73W x 4.52D inches 13.2cmH x 6.934cmW x 11.48cmD Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Mini-DIN RS-232 only No hardware handshaking Ethernet Port 10Base-T Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration RIO Connector 3 pos screw-terminal adaptor(j803) RIO LED Indicators Active - Green PROFIBUS Connector DB-9F Standard PROFIBUS connector and isolated Opto-Couplers PROFIBUS LED Ready, Run, Error and Token LED Indicators Indicators Shipped with each unit Mini-DIN to DB-9M cables per serial port 4 ft RS-232 configuration cable 2.5mm screwdriver CD (documentation and Configuration utility) Regulatory Approvals ISA ISA Class 1 Div 2 CSA/cUL C22.2 No Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following. If you are unsure which product to select, please contact your local distributor. Rockwell Automation Remote I/O to PROFIBUS DP-V1 Master Gateway 5604-RIO-PDPMV1 To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved.. 11/18/2008 s subject to change without notice

318 Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway 5605-RIO-PDPS The RIO-PDPS modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP master device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave support, the module provides a very powerful interface to the many PROFIBUS master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway 5605-RIO-PDPS The ProLinx Rockwell Automation Remote I/O Adapter to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Remote I/O network and a PROFIBUS master device. This stand-alone DIN-rail mounted protocol gateway provides one Remote I/O port and one PROFIBUS DP Slave configurable DB9F port. The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images. The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool. Rockwell Automation Remote I/O The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images. Software Configurable Parameters Rack Number Addressing 0 to 63 Rack Size ¼-rack, ½-rack, ¾-rack and full rack Starting Group 0,2,4,6 Last Rack Yes or No Baud Rate 57.6K, 115K, 230K Functional s Supports block-transfers of data with scanner Supports I/O data movement. Amount determined by rack size configuration BTW Command up to 64 words BTR Command up to 63 words Physical Connection Remote I/O connector Standard 3-screw termination connector Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

319 PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database General s The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today. Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal 18 to 36 VDC allowed Positive, Negative, GND Terminals 2.5 mm screwdriver blade 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status Configuration Serial Port Ethernet Port (Ethernet modules only) Application Serial Ports Serial Port Isolation Shipped with Each Unit DB-9M RS-232 only No hardware handshaking RJ45 Connector Link and Activity LED indicators RS-232/422/485 RS-232 handshaking configurable RS-422/485 screw termination included 2500V RMS port signal isolation per UL V DC min. port to ground and port to logic power isolation Mini-DIN to DB-9M serial cables 4 ft RS-232 configuration cable 2.5mm screwdriver CD (docs and Configuration utility) RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 5605-RIO-PDPS Rockwell Automation Remote I/O to PROFIBUS DP Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

320 Wireless IEC Server Gateway 6201-WA-104S The IEC Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 devices. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Wireless IEC Server Gateway 6201-WA-104S The ProLinx Wireless IEC Server Gateway creates a powerful wireless connection between devices on an IEC 104 Server network. The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. IEC Server Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers. The 104S module acts as an input/output module between the IEC Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include: User-definable module memory usage Protocol implementation conforms to the IEC specification with fully configurable parameters SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. IEC Server Configurable Parameters Override StartDT Clear queue on close t1 timeout set value t2 timeout set value t3 timeout set value k (maximum queue) w (latest ack threshold) Time DB Offset

321 ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels: user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports Two RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10-5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals. 500 ma max@ 24 VDC -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Configuration Serial Port Ethernet Port Application Serial Ports Antenna ports Shipped with each unit Mini-DIN, RS-232 only No hardware handshaking RJ45 10Base-T Connector. Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-persecond and less than or equal to 5 minutes duration Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 6201-WA-104S Wireless IEC Server Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. February 27, 2008

322 Brasil , Languages spoken include: Portuguese, English Wireless ASCII Generic Serial Gateway 6201-WA-ASCII The WA-ASCII module is the ideal solution for the many applications where wireless connectivity can be used to integrate an ASCII generic serial input device into a system. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. In combination with the ASCII device support, the module provides a very powerful interface to the many ASCII input devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English DISCONTINUED Wireless ASCII Generic Serial Gateway 6201-WA-ASCII The ProLinx Wireless ASCII Generic Serial Gateway creates a powerful wireless connection between ASCII input devices. The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. ASCII The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc). The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave (Receive ASCII strings), or both. ASCII s Ports Available in up to four port configurations to receive and/or transmit data. Transmit and Receive buffer size Transmit character with pacing 255 bytes each 0 to millisecond delay between each transmitted character. ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each

323 other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels: user selectable Security Antenna Ports 1 through 11* ** PWP + WEP 64/128 Encryption with WEP key rollover management Two RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10-5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals 500 ma max@ 24 VDC -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Configuration Serial Port Application Serial Ports Antenna Ports Port Isolation Shipped with each unit Mini-DIN RS-232 only No hardware handshaking Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. 2500V Opto-Isolators 500V Power Supply Isolation Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013

324 DISCONTINUED Wireless DF1 Master/Slave Gateway 6201-WA-DFCM The ProLinx Wireless DF1 Master/Slave Gateway creates a powerful wireless connection between DF1 Slave devices. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. Wireless DF1 Master/Slave Gateway 6201-WA-DFCM The WA-DFCM modules are the ideal solution for the many applications where wireless connectivity can be used to integrate DF1 devices into a system. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking BCC and CRC Miscellaneous Full hardware handshaking control, providing radio, smart modem and Multidrop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex Master (Module generates commands) Half-Duplex Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

325 DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex Slave (not peer mode) Half Duplex Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports (2) RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10 5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions LED Indicators Configuration Serial Port Application Serial Ports Antenna Ports Port Isolation Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Mini-DIN RS-232 only No hardware handshaking Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. 2500V Opto-Isolators 500V Power Supply Isolation Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013

326 Wireless EtherNet/IP Gateway 6201-WA-DFNT The WA-DFNT modules are the ideal solution for the many applications where wireless EtherNet/IP connectivity can be used to integrate devices into a system. The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Wireless EtherNet/IP Gateway 6201-WA-DFNT The ProLinx Wireless EtherNet/IP Gateway creates a powerful wireless connection between devices on an EtherNet/IP network. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. User-configurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start - Fixed at N10 Data Table File Size or 1000 words CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. Polling of command list User configurable polling of commands, including disabled, continuous and on change of data (write only).

327 ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels: user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports Two RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10-5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals. LED Indicators Configuration Serial Port Ethernet Port Application Serial Ports Antenna ports Shipped with each unit Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Mini-DIN, RS-232 only No hardware handshaking RJ45 10Base-T Connector. Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-persecond and less than or equal to 5 minutes duration Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013 Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 500 ma max@ 24 VDC -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD)

328 North America , Languages spoken include: English, Spanish Latin America (Sales only) , Languages spoken include: Spanish, English Brasil , Languages spoken include: Portuguese, English Wireless EtherNet/IP to DF1 Master/Slave Gateway 6202-WA-DFNT-DFCM3 The WA-DFNT-DFCM modules are ideal for the many applications where wireless EtherNet/IP connectivity can integrate DF1 devices into a system. The EtherNet/IP gateway is designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs. With the DF1 Master/Slave device support, the module provides a powerful interface to the many DF1 devices in the industrial marketplace today. Data is exchanged between devices and/or networks using a shared common database and an efficient wireless protocol. This common database provides "backbone" communications for various devices using different networks. Applications are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English DISCONTINUED Wireless EtherNet/IP to DF1 Master/Slave Gateway 6202-WA-DFNT-DFCM3 The ProLinx Wireless EtherNet/IP to DF1 Master/Slave Gateway creates a powerful wireless connection between devices on an EtherNet/IP network and DF1 devices. The EtherNet/IP protocol driver supports the Explicit Messaging implementation of the protocol. Userconfigurable as both a Client and a Server, the EtherNet/IP port is a very powerful data transfer tool. The DF1 protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. EtherNet/IP The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. General Protocol Information Messaging PCCC on CIP Explicit Messaging supported Miscellaneous 125 word read and write data lengths Floating point data supported

329 EtherNet/IP Server s In Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers. EtherNet/IP Server s Connections Five independent TCP server sockets permit remote clients to interact with all data contained in the module. Data File Data Table File Start - Fixed at N10 Data Table File Size or 1000 words CIP Services Supported 0x4C - CIP Data Table Read 0x4D - CIP Data Table Write EtherNet/IP Client s In Client mode, the module controls the read/write data transfer between the gateway and other EtherNet/IP devices. Data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware. EtherNet/IP Client s General One client Command List Polling of command list Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count. User configurable polling of commands, including disabled, continuous and on change of data (write only). DF1 Master/Slave The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is userconfigurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc). General Parameters Communication parameters Error Checking Miscellaneous Local Station ID: 0 to 254 Ports 1 to 3 Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to milliseconds BCC and CRC Full hardware handshaking control, providing radio, smart modem and multi-drop support Floating point data supported DF1 Master Protocol s The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices. DF1 Master Driver DF1 Modes Command List Polling of Command List Full-Duplex - Master (Module generates commands) Half-Duplex - Polling Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count User-configurable polling of commands, including disabled, continuous, and on change of data (write only) DF1 Slave Protocol s The ports on the module can be individually configured to support the Slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers. DF1 Slave Driver DF1 Modes Configurable parameters per slave port Full Duplex - Slave (not peer mode) Half Duplex - Polled Data Table File Start (File N[x] 0 to 999) Data Table File Size (1 to 1000 words) Data Table location in database (0 to 3999) ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol.

330 Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels: user selectable Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports Two RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10-5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. 1 through 11* ** Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals. 500 ma max@ 24 VDC Operating -20 to 50 C (-4 to 122 F) Temperature Storage Temperature -40 to 85 C (-40 to 185 F) Relative Humidity 5% to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Configuration Serial Port Application Serial Ports Antenna ports Shipped with each unit Mini-DIN, RS-232 only No hardware handshaking Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013

331 Wireless HART Multi-drop Gateway 6207/6227-WA-HART(2) The ProLinx High Speed Wireless to HART Multi-drop Gateways create a powerful connection between devices on an wireless network and HART Multi-drop devices. The module provides one wireless port and four HART Multi-drop channels. The ProLinx 6000 series of wireless gateways will provide users more flexibility than ever before seen in wireless solutions. Users will be able to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by selecting the appropriate protocol/network that provides a connection to the hardwire device, the protocol is then converted into a common radio packet, "ProSoft Wireless Protocol" (PWP) or to standard industry protocols such as HART to other wireless gateways in the system. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English DISCONTINUED Wireless HART Multi-drop Gateway 6207/6227-WA-HART(2) The ProLinx Wireless HART Multi-drop Gateway creates a powerful connection between devices on a wireless network and HART devices. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable. ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. HART The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module. The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15. General Parameters Communication parameters Number of HART Preambles: 2 to 50 Enable Handheld: Y or N Primary Master: Y or N Configurable Parameters Auto-Poll Enable, Short / Long Address per Channel Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English

332 HART Driver Command List Polling of command list Up to 100 fully configurable commands per channel User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled. HART is a registered trademark of the HART Communication Foundation General s Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports (2) RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10 5 * Varies with country regulation ** Some European countries such as France allow fewer channels Application Serial Ports Antenna Ports Port Isolation Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. 2500V Opto-Isolators 500V Power Supply Isolation Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) HART HART modules ship with the necessary screw terminal adapters to connect your devices directly to the gateway. ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013 Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Mini-DIN RS-232 only No hardware handshaking

333 Wireless Modbus Plus Gateway 6303-WA-MBP The WA-MBP modules are the ideal solution for the many applications where wireless Modbus Plus connectivity can be used to integrate devices into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others).data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English DISCONTINUED Wireless Modbus Plus Gateway 6303-WA-MBP The ProLinx Wireless Modbus Plus Gateway creates a powerful wireless connection between devices on a Modbus Plus network. The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Modbus Plus The Modbus Plus protocol driver exists in a single Modbus Plus Port (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices. General Parameters Modbus Function Codes Address Scope 1 to 64 3: Read Multiple Data Registers (MSTR 2) 16: Write Multiple Data Register (MSTR 1) Global data read (32 words max.) Global data write (32 words max.) Modbus Plus Functioning as a Master Command List Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count Polling of command list Configurable polling of command list, including continuous and on change of data Modbus Plus Functioning as a Slave Node address 1 to 64 software selectable ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless

334 bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, LED Indicators Power and Module Status, Broadcast and Multicast group messaging. Efficiency is Application Status, Serial Port based on the fact each device on the "wireless" network Activity LED, Serial Activity and can produce these types of messages and each device determines which of these messages to consume. Error LED Status, RF Link Status, RF Data Status General s Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The Configuration Serial Port Application Serial Ports Mini-DIN RS-232 only No hardware handshaking Mini-DIN, RS-232/422/485 RS232 handshaking configurable modules function as a client, providing an ultra-fast RS422/485 screw termination wireless solution for the most demanding industrial included applications. Antenna Ports Two RP-SMA connectors, with automatic antenna diversity. These modules allow you to connect various field Port Isolation 2500V Opto-Isolators devices using different networks or protocols and share 500V Power Supply Isolation data between these devices "over-the-air." This is Shipped with each unit Mini-DIN to DB-9M cables per accomplished by exchanging shared common database serial port, 4 ft RS-232 information over-the-air with ProSoft Technology's configuration cable, 2.5mm efficient but powerful wireless protocol. screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 Frequency 2.4 GHz band (2400 to MHz)* to 4, depending on ports) Wireless medium DSSS Direct Sequence Spread Spectrum (802.11b) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick Output power 32 mw (15 dbm) and easy way to manage module configuration files Channel data rates 11, 5.5, 2, 1 Mbps customized to meet your application needs. PCB is not Channels user 1 through 11* ** only a powerful solution for new configuration files, but selectable also allows you to import information from previously Security PWP + WEP 64/128 Encryption with WEP key rollover management installed (known working) configurations to new projects. Antenna Ports (2) RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10 5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Dimensions Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Copyright ProSoft Technology, Inc All Rights Reserved. December 17, 2013

335 Wireless Modbus Master/Slave Gateway 6201-WA-MCM The WA-MCM modules are the ideal solution for the many applications where wireless Modbus connectivity can be used to integrate devices into a system. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. In combination with the Modbus device support, the module provides a very powerful interface to the many Modbus devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Wireless Modbus Master/Slave Gateway 6201-WA-MCM The ProLinx Wireless Modbus Master/Slave Gateway creates a powerful wireless connection between devices on a Modbus network. The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Modbus Master/Slave The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.). General Parameters Modbus Protocol Communication Baud Rate: 110 to 115K baud parameters Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to ms Error Checking RTU mode (binary) with CRC-16 ASCII mode with LRC error checking Floating Point Floating point data movement supported, including configurable support for Enron implementation Function Codes Modbus Master Command List Polling of command list Modbus Slave Node address 1: Read Output Status 2: Read Input Status 3: Read Multiple Data Registers 4: Read Input Registers 5: Write Single Bit 6: Write Single Data Register 15: Write Multiple Bits 16: Write Multiple Data Register Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count. Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. 1 to 247 software selectable

336 ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports (2) RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10 5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions 24 VDC nominal, 18 to 36 VDC allowed. Positive, Negative, GND Terminals 500 ma max@ 24 VDC 20 to 50 C ( 4 to 122 F) 40 to 85 C ( 40 to 185 F) 5 to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) LED Indicators Configuration Serial Port Application Serial Ports Antenna Ports Port Isolation Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Mini-DIN RS-232 only No hardware handshaking Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. 2500V Opto-Isolators 500V Power Supply Isolation Shipped with each unit Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 6201-WA-MCM Wireless Modbus Master/Slave Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. May 03, 2007

337 Wireless Modbus TCP/IP Gateway 6201-WA-MNET The WA-MNET modules are the ideal solution for the many applications where wireless Modbus TCP/IP connectivity can be used to integrate devices into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe - Middle East - Africa +33 (0) , support.emea@prosoft-technology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Wireless Modbus TCP/IP Gateway 6201-WA-MNET The ProLinx wireless Modbus TCP/IP Gateway creates a powerful wireless connection between devices on a Modbus TCP/IP network. The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well. ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. Modbus TCP/IP The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices. Modbus TCP/IP Server General Configurable Parameters Modbus TCP/IP Client General Configurable parameters Command List Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port Module IP Address Modbus address offsetting Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer Up to 100 fully configurable commands on the Client port ProSoft Wireless Protocol ProSoft Wireless Protocol (PWP) offers versatility where a mix of control devices requires cooperation with each other. This involves sharing of information across the applications regardless of device or network type, often at high speed, and with high reliability. Wireless bandwidth utilization is optimized by using efficient communication methods. The protocol supports Unicast, Broadcast and Multicast

338 group messaging. Efficiency is based on the fact each device on the "wireless" network can produce these types of messages and each device determines which of these messages to consume. General s - Radio Modules These modules utilize a full function wireless network card, supporting RF data rates up to 11 Mbps. The modules function as a client, providing an ultra-fast wireless solution for the most demanding industrial applications. These modules allow you to connect various field devices using different networks or protocols and share data between these devices "over-the-air." This is accomplished by exchanging shared common database information over-the-air with ProSoft Technology's efficient but powerful wireless protocol. Frequency 2.4 GHz band (2400 to MHz)* Wireless medium DSSS: Direct Sequence Spread Spectrum (802.11b) Output power 32 mw (15 dbm) Channel data rates 11, 5.5, 2, 1 Mbps Channels: user selectable 1 through 11* ** Security PWP + WEP 64/128 Encryption with WEP key rollover management Antenna Ports Two RP-SMA connectors, automatic antenna diversity Bit Error Rate (BER) Better than 10-5 * Varies with country regulation ** Some European countries such as France allow fewer channels Hardware s Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port 24 VDC nominal, 18 to 32 VDC allowed. Positive, Negative, GND Terminals. 500 ma max@ 24 VDC -20 to 50 C (-4 to 122 F) -40 to 85 C (-40 to 185 F) 5% to 95% (non-condensing) Standard: 5.20H x 2.07W x 4.52D inches (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D inches (13.2cmH x 6.934cmW x 11.48cmD) Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status, RF Link Status, RF Data Status Mini-DIN, RS-232 only No hardware handshaking Ethernet Port Application Serial Ports Antenna ports Shipped with each unit RJ45 10Base-T Connector. Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-persecond and less than or equal to 5 minutes duration Mini-DIN, RS-232/422/485 RS232 handshaking configurable RS422/485 screw termination included Two RP-SMA connectors, with automatic antenna diversity. Mini-DIN to DB-9M cables per serial port, 4 ft RS-232 configuration cable, 2.5mm screwdriver, CD (docs and Configuration utility), RS-422/485 DB9 to Screw Terminal Adaptor (1 to 4, depending on ports) ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects. Additional Products ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at for a complete list of products. Ordering Information To order this product, please use the following: 6201-WA-MNET Wireless Modbus TCP/IP Gateway To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to Distributors: Place your order by or fax to: North American / Latin American / Asia Pacific orders@prosoft-technology.com, fax to Europe europe@prosoft-technology.com, fax to +33 (0) Copyright ProSoft Technology, Inc All Rights Reserved. February 27, 2008

339 Wireless PROFIBUS Gateways 6104-WA-PDPM / 6105-WA-PDPS The modules offer one-to-one or one-to-many PROFIBUS interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks. How to Contact Us: Sales and Support All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or Asia Pacific , asiapc@prosoft-technology.com Languages spoken include: Chinese, Japanese, English Europe Middle East Africa +33 (0) , support.emea@prosofttechnology.com Languages spoken include: French, English North America , support@prosoft-technology.com Languages spoken include: English, Spanish Latin America (Sales only) , latinam@prosoft-technology.com Languages spoken include: Spanish, English Brasil , eduardo@prosoft-technology.com Languages spoken include: Portuguese, English Wireless PROFIBUS DP Gateways 6104-WA-PDPM 6105-WA-PDPS PROFIBUS DP Master The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to continuously interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. General Parameters Communication parameters PROFIBUS Master Command List Node address Status Data Baud Rate: 9.6 kbit/s 12 Mbit/s Read Diag Global Cmd Read Cntrs Reset Cntrs software selectable. Error codes, counters and port status available per configured slave on the network. PROFIBUS DP Slave The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols. General Parameters GSD File PROFIBUS s Communication parameters Supported I/O length Supported PROFIBUS DP features PRLX05A5.GSD Downloadable from ProSoft Technology web site Baud Rate: 9.6 kbit/s 12 Mbit/s 244 bytes Input data 244 bytes Output data 400 bytes total PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting Configurable Parameters PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database

EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO

EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO The EtherNet/IP to Allen-Bradley Data Highway Plus or Remote I/O Gateway provides solutions for some commonly encountered issues where

More information

Technical Note. ProSoft Technical Publications. RLXIC-Sx Serial Cellular Radio Application Setup Guide

Technical Note. ProSoft Technical Publications. RLXIC-Sx Serial Cellular Radio Application Setup Guide Technical Note ProSoft Technical Publications RLXIC-Sx Serial Cellular Radio Application Setup Guide Document Information Author Jim Schliem Description Detailed setup instructions for specific cellular

More information

4205/5205-TS-104S-PDPS

4205/5205-TS-104S-PDPS 4205/5205-TS-104S-PDPS ProLinx Standalone User Manual Please Read This Notice Successful application of this module requires a reasonable working knowledge of the ProLinx Module, its connected devices,

More information

104S v2 PROTOCOL MANUAL. ProLinx Gateway IEC Server (Firmware v2.xx) March 19, 2010

104S v2 PROTOCOL MANUAL. ProLinx Gateway IEC Server (Firmware v2.xx) March 19, 2010 104S v2 ProLinx Gateway IEC 60870-5-104 Server PROTOCOL MANUAL Important Installation Instructions Power, Input, and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article

More information

Technical Note. MVI56(E)-MNETR Add-On Instruction Installation Guide

Technical Note. MVI56(E)-MNETR Add-On Instruction Installation Guide MVI56(E)-MNETR Add-On Instruction Installation Guide Modbus TCP/IP Ethernet Communication Module Author: ProSoft Technical Publications Date: November 06, 2009 Document Information Author ProSoft Technical

More information

DH485 DRIVER MANUAL. ProLinx Gateway DH485 Interface. August 27, 2009

DH485 DRIVER MANUAL. ProLinx Gateway DH485 Interface. August 27, 2009 DH485 ProLinx Gateway DRIVER MANUAL Important Installation Instructions Power, Input and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501-4 (b) of the National

More information

Technical Note PLX82-MNET-61850

Technical Note PLX82-MNET-61850 Performance Measurement Document Code: TN-004-11- Author: Marcio Rodrigues. Kentaro Seki, Neven Grgas Date: 11/08/11 Document Information Author Marcio Rodrigues, Kentaro Seki, Neven Grgas Description

More information

Stand-Alone Industrial Gateways

Stand-Alone Industrial Gateways Stand-Alone Industrial Gateways Application Solutions with ProLinx Table of Contents 2 Stand-Alone Gateways 3 Port Expanders 4 Ethernet Gateways 5 Field Instrumentation 5000 Series 6000 Series 7000 Series

More information

ProLinx DNPS. ProLinx Gateway DNP 3.0 Slave USER MANUAL

ProLinx DNPS. ProLinx Gateway DNP 3.0 Slave USER MANUAL ProLinx DNPS ProLinx Gateway USER MANUAL December 01, 2009 Important Installation Instructions Power, Input, and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article

More information

MVI69-101S. CompactLogix or MicroLogix Platform IEC Slave Communication Module USER MANUAL

MVI69-101S. CompactLogix or MicroLogix Platform IEC Slave Communication Module USER MANUAL MVI69-101S CompactLogix or MicroLogix Platform IEC 60870-5-101 Slave Communication Module USER MANUAL 3/16/2009 MVI (Multi Vendor Interface) Modules WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT

More information

IMC-BHx-AC INSTALLATION GUIDE. Industrial Media Converter. Ethernet over Belden 9463 Blue Hose

IMC-BHx-AC INSTALLATION GUIDE. Industrial Media Converter. Ethernet over Belden 9463 Blue Hose IMC-BHx-AC Industrial Media Converter Ethernet over Belden 9463 Blue Hose INSTALLATION GUIDE IMC-BHx-AC Installation Guide Your Feedback Please We always want you to feel that you made the right decision

More information

101M ProLinx Gateway IEC Master

101M ProLinx Gateway IEC Master 101M ProLinx Gateway March 14, 2012 PROTOCOL MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments

More information

MBP DRIVER MANUAL. ProLinx Gateway Modbus Plus. July 10, 2018

MBP DRIVER MANUAL. ProLinx Gateway Modbus Plus. July 10, 2018 MBP ProLinx Gateway DRIVER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints about

More information

Technical Note. Converting Modbus applications from a 3150-MCM to an MVI46-MCM. Document Code: TN Author: Steve Crippen Date:

Technical Note. Converting Modbus applications from a 3150-MCM to an MVI46-MCM. Document Code: TN Author: Steve Crippen Date: Converting Modbus applications from a 3150-MCM to an MVI46-MCM Document Code: Author: Steve Crippen Date: 01 2015 Document Information Author Steve Crippen Description Describes how to convert a Modbus

More information

ILX34-MBS QUICK START GUIDE. Quick Start Guide. March 10, 2014

ILX34-MBS QUICK START GUIDE. Quick Start Guide. March 10, 2014 ILX34-MBS Quick Start Guide QUICK START GUIDE ILX34-MBS Quick Start Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments,

More information

Technical Note. Rockwell Automation ControlLogix PLC Communications with 4B Watchdog Super Elite via a ProSoft Technology PLX31-EIP-MBTCP

Technical Note. Rockwell Automation ControlLogix PLC Communications with 4B Watchdog Super Elite via a ProSoft Technology PLX31-EIP-MBTCP Rockwell Automation ControlLogix PLC Communications with 4B Watchdog Super Elite via a ProSoft Technology PLX31-EIP-MBTCP Author: Bobby Maxwell Date: July 2016 Document Information Author Bobby Maxwell

More information

ISDA/ISDA4 Protocol Driver Manual. Table of Contents

ISDA/ISDA4 Protocol Driver Manual. Table of Contents ISDA/ISDA4 Protocol Driver Manual Table of Contents ISDA 1 Functional Overview... 3 1.1 Master Serial Port(s)... 3 1.2 Module Internal Database... 4 1.2.1 ISDA Serial Port Driver Access to Database...

More information

MVI46-103M. User Manual. SLC Platform. IEC Master Communication Module

MVI46-103M. User Manual. SLC Platform. IEC Master Communication Module MVI46-103M SLC Platform IEC 60870-5-103 Master Communication Module User Manual Please Read This Notice Successful application of this module requires a reasonable working knowledge of the Rockwell Automation

More information

RS485 I/O Expansion System

RS485 I/O Expansion System RS485 I/O Expansion System USER GUIDE User Guide Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or

More information

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT

More information

MVI46-MCM SLC Platform Modbus Interface Module USER MANUAL. February 5, 2004

MVI46-MCM SLC Platform Modbus Interface Module USER MANUAL. February 5, 2004 MVI46-MCM SLC Platform Modbus Interface Module USER MANUAL ProSoft Technology, Inc. 1675 Chester Avenue Fourth Floor Bakersfield, CA 93301 (661) 716-5100 (661) 716-5101 Fax prosoft@prosoft-technology.com

More information

MPU-32 AND FPU-32 TIA-485 NETWORK

MPU-32 AND FPU-32 TIA-485 NETWORK 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/protectionrelays MPU-32 AND FPU-32 TIA-485 NETWORK SEPTEMBER 5, 2006 PRELIMINARY Publication: MPU-32/FPU-32

More information

Using Add-On Instruction and CIPconnect TM

Using Add-On Instruction and CIPconnect TM Technical Note Introduction The goal of this technical note is to allow any user to successfully achieve the complete MVI56-PDPMV1 setup. When the user will have followed the procedure, the module will

More information

FreyrSCADA Embedded Solution

FreyrSCADA Embedded Solution FreyrSCADA Embedded Solution Software Document IEC 60870-5-101 Server Simulator User Manual Stack Version: 21.04.001 Document version: 16.07.26 Online Check the latest version IEC 60870-5-101 Product Table

More information

ProLinx REFERENCE GUIDE. Standalone Gateways Configuration and Troubleshooting 10/13/2009

ProLinx REFERENCE GUIDE. Standalone Gateways Configuration and Troubleshooting 10/13/2009 ProLinx Standalone Gateways 10/13/2009 REFERENCE GUIDE Important Installation Instructions Power, Input, and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501-4

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

MVI56E-LDM QUICK START GUIDE. ControlLogix Platform. C Programmable Linux Application Development Module

MVI56E-LDM QUICK START GUIDE. ControlLogix Platform. C Programmable Linux Application Development Module MVI56E-LDM ControlLogix Platform C Programmable Linux Application Development Module QUICK START GUIDE Your Feedback Please We always want you to feel that you made the right decision to use our products.

More information

S3964R DRIVER MANUAL. ProLinx Gateway Siemens 3964R Protocol. April 14, 2009

S3964R DRIVER MANUAL. ProLinx Gateway Siemens 3964R Protocol. April 14, 2009 S3964R ProLinx Gateway DRIVER MANUAL Important Installation Instructions Power, Input and Output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501-4 (b) of the National

More information

ILX34-MBS. User Manual Modbus Serial Module for CompactLogix L1 and Point I/O Adapters USER MANUAL

ILX34-MBS. User Manual Modbus Serial Module for CompactLogix L1 and Point I/O Adapters USER MANUAL ILX34-MBS User Manual Modbus Serial Module for CompactLogix L1 and Point I/O Adapters USER MANUAL User Manual Your Feedback Please We always want you to feel that you made the right decision to use our

More information

IEC Protocol Interoperability List

IEC Protocol Interoperability List IEC 60870-5-104 Protocol Interoperability List Network configuration Point-to-point Multiple point-to-point Multipoint-party line Multipoint-star Physical layer Transmission speed (control direction) Unbalanced

More information

IEC Master Communication Protocol

IEC Master Communication Protocol IEC-60870-5-104 Master Communication Protocol Summary 1. GENERAL INFORMATION... 1 1.1 Summary... 1 1.2 Supported Object Data (ASDUs)... 1 1.3 General Operation... 2 2. CHANNEL SETTINGS... 3 2.1 Protocol

More information

MVI46-DFNT SLC Platform EtherNet/IP Client/Server Communication Module

MVI46-DFNT SLC Platform EtherNet/IP Client/Server Communication Module MVI46-DFNT SLC Platform EtherNet/IP Client/Server Communication Module USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions,

More information

5209-MNET-CCLINK SETUP GUIDE

5209-MNET-CCLINK SETUP GUIDE 5209-MNET-CCLINK ProLinx Stand-alone Communications Gateway Modbus TCP/IP Client/Server to CC-Link Local Station & Intelligent Device version 1.10 SETUP GUIDE 3/11/2009 Important Installation Instructions

More information

IEC Interoperability Profile

IEC Interoperability Profile IEC 60870-5-104 Interoperability Profile 2 9 Interoperability This companion standard presents sets of parameters and alternatives from which subsets must be selected to implement particular telecontrol

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

FreyrSCADA Embedded Solution

FreyrSCADA Embedded Solution FreyrSCADA Embedded Solution IEC 60870-5-101 Client Stack Interoperability Stack Version: 21.04.001 Document version: 17.10.028 Check the latest version @ online IEC 60870-5-101 Product 8 Interoperability

More information

PLX3x Series USER MANUAL. Multi-Protocol Gateways. November 8, 2017

PLX3x Series USER MANUAL. Multi-Protocol Gateways. November 8, 2017 PLX3x Series Multi-Protocol Gateways USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or

More information

APNT#1208 GP-Pro EX to Allen Bradley RIO via Gateway. Explore Newer Solutions

APNT#1208 GP-Pro EX to Allen Bradley RIO via Gateway. Explore Newer Solutions Application Note #1208: GP-Pro EX to Allen Bradley RIO via Gateway Explore Newer Solutions When upgrading your existing HMI consider updating the communications to current technology. Pro-face GP-Pro EX

More information

FreyrSCADA Embedded Solution

FreyrSCADA Embedded Solution FreyrSCADA Embedded Solution IEC 60870-5-104 Client Stack Interoperability Stack Version: 21.04.001 Document version: 16.07.28 Check the latest version @ online IEC 60870-5-104 Product 1. Interoperability

More information

IEC Interoperability Document

IEC Interoperability Document IEC60870-5-104 Interoperability Document This companion standard presents sets of parameters and alternatives from which subsets must be selected to implement particular telecontrol systems. Certain parameter

More information

Industrial Protocol Gateway

Industrial Protocol Gateway Industrial Protocol Gateway PG5901 Series Feature Highlights Dual 10/100 Mbps Ethernet port, PoE PD 1-port RS-232/422/485, baud rate up to 921.6 Kbps IP30 Metal housing with Aluminum heat sink Strong EMC

More information

PLX3x Series. Ethernet and Serial Gateways USER MANUAL

PLX3x Series. Ethernet and Serial Gateways USER MANUAL PLX3x Series USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints about our products,

More information

SystemCORP. Embedded Technology Pty Ltd. IEC Library (PIS21) Interoperability

SystemCORP. Embedded Technology Pty Ltd. IEC Library (PIS21) Interoperability SystemCORP Embedded Technology Pty Ltd IEC 60870-5-101 Library (PIS21) Copyright: All rights reserved. None of the information contained in this document may be reproduced or stored in a database or retrieval

More information

PLX35-NB2 RELEASE NOTES. Network Bridge Stand Alone Gateway. July 20, 2018

PLX35-NB2 RELEASE NOTES. Network Bridge Stand Alone Gateway. July 20, 2018 PLX35-NB2 Network Bridge RELEASE NOTES Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments or complaints

More information

IEC Configuration/Interoperability Guide for SICAM SGU 7XV5676

IEC Configuration/Interoperability Guide for SICAM SGU 7XV5676 IEC 60870-5-104 Configuration/Interoperability Guide for SICAM SGU 7V5676 7V5676-xJJx SICAM SGU with Binary IO 7V5676-xJLx SICAM SGU with Binary IO and Analog IO DOCUMENT VERSION V1.11 MARCH, 2014 E50417-

More information

Industrial Protocol Gateway

Industrial Protocol Gateway PG5908/PG5916 Series Industrial Protocol Gateway Feature Highlights Dual 10/100Mbps Ethernet ports, Embedded IPsec VPN for enhanced security Remotely monitor, manage, and control industrial field devices

More information

CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS

CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS This configuration guide provides programming information for the DL-PC (ISA) and DL-STD (STD 80 and 32) Remote I/O Link applications.

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Allen-Bradley. PowerFlex DSI Communication Adapters. DeviceNet (22-COMM-D) EtherNet/IP (22-COMM-E) PROFIBUS (22-COMM-P) RS-232 DF1 Module (22-SCM-232)

Allen-Bradley. PowerFlex DSI Communication Adapters. DeviceNet (22-COMM-D) EtherNet/IP (22-COMM-E) PROFIBUS (22-COMM-P) RS-232 DF1 Module (22-SCM-232) Communications PowerFlex DSI Communication Adapters DeviceNet (22-COMM-D) EtherNet/IP (22-COMM-E) PROFIBUS (22-COMM-P) RS-232 DF1 Module (22-SCM-232) Communications 22-COMM-D DeviceNet Adapter The PowerFlex

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

MVI56-DNPSNET ControlLogix Platform DNP 3.0 Server over Ethernet Communication Module

MVI56-DNPSNET ControlLogix Platform DNP 3.0 Server over Ethernet Communication Module MVI56-DNPSNET ControlLogix Platform DNP 3.0 Server over Ethernet Communication Module USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If

More information

PLX51-DF1-ENI. DF1 Router DF1 to EtherNet/IP TM Router USER MANUAL

PLX51-DF1-ENI. DF1 Router DF1 to EtherNet/IP TM Router USER MANUAL PLX51-DF1-ENI DF1 Router DF1 to EtherNet/IP TM Router USER MANUAL December, 2017 Preface Page 2 of 81 Preface CONTENTS 1. Preface... 5 1.1. Introduction to the PLX51-DF1-ENI... 5 1.2. Features... 6 1.3.

More information

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation GT200-DP-RS V6.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Gateway...4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical Specifications... 4 1.4 Related

More information

IEC Master Driver PTC Inc. All Rights Reserved.

IEC Master Driver PTC Inc. All Rights Reserved. 2018 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 4 Overview 4 Setup 5 Channel Properties General 5 Channel Properties Serial Communications 6 Channel Properties Write Optimizations

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

SystemCORP. Embedded Technology Pty Ltd. IEC Library (PIS20) Interoperability

SystemCORP. Embedded Technology Pty Ltd. IEC Library (PIS20) Interoperability SystemCORP Embedded Technology Pty Ltd IEC 60870-5-104 Library (PIS20) Copyright: All rights reserved. None of the information contained in this document may be reproduced or stored in a database or retrieval

More information

MVI69-PDPS. CompactLogix or MicroLogix Platform Profibus DP Slave Communication Module USER MANUAL

MVI69-PDPS. CompactLogix or MicroLogix Platform Profibus DP Slave Communication Module USER MANUAL MVI69-PDPS CompactLogix or MicroLogix Platform USER MANUAL 10/31/2008 Please Read This Notice Successful application of this module requires a reasonable working knowledge of the Rockwell Automation CompactLogix

More information

PS69-DPS. CompactLogix or MicroLogix Platform Profibus DP Slave Communication Module USER MANUAL

PS69-DPS. CompactLogix or MicroLogix Platform Profibus DP Slave Communication Module USER MANUAL PS69-DPS CompactLogix or MicroLogix Platform Profibus DP Slave Communication Module USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If

More information

Allen-Bradley Automation

Allen-Bradley Automation Product Data 1791D CompactBlock I/O for DeviceNet 1791D CompactBlock I/O modules contain I/O circuits, a built-in power supply, and a built-in DeviceNet I/O adapter. CompactBlock I/O modules are ideal

More information

Select Family: MicroLogix 1100 or 1400 Controller

Select Family: MicroLogix 1100 or 1400 Controller Select Family: MicroLogix 1100 or 1400 Controller 21 Select Family: MicroLogix 1100 or 1400 Controller Step 1 - Select: controller family - based on memory, I/O, added functionality, programming instructions

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. ) PROFIBUS-DP

More information

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet VIPA CPU 115DP (115-6BL22) Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO

More information

ReLab Protocol Server Bridge Manual. (925)

ReLab Protocol Server Bridge Manual. (925) ReLab Protocol Server Bridge Manual (925) 262-4244 http://www.relabsoft.com contact@relabsoft.com Overview ReLab Protocol Server Bridge implements Slave capability of IEC 60870-5-101, IEC 60870-5-104,

More information

M-series Profibus DP Series 2 Plus Interface Card

M-series Profibus DP Series 2 Plus Interface Card January 2013 Page 1 M-series Profibus DP Series 2 Plus Interface Card The DeltaV M-series Profibus DP Interface Card provides the solution for interfacing to discrete actuators and sensors. Offers freedom

More information

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000

More information

KTA-250 Anemometer Alarm Card

KTA-250 Anemometer Alarm Card Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments

More information

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Simple but elegant look and ease of installation make it ideal for various industrial applications. This LDD240-WU DC/DC converter is the optimal response to the applications where compactness and high reliability are requested. It is isolated and offers a wide range of input and output voltages. Simple

More information

IEC Interoperability Document for:

IEC Interoperability Document for: w w w. s t r e a m x. c h IEC 60870-5-101 Interoperability Document for: StreamBridge: Stream870-5-101 Version Informations Last activities Date Author File 02/23/2012 Infoteam / FD Interoperability StreamBridge

More information

MVI46-BDW. User Manual. SLC Platform. BARDAC Drive Web Interface

MVI46-BDW. User Manual. SLC Platform. BARDAC Drive Web Interface MVI46-BDW SLC Platform User Manual Please Read This Notice Successful application of this module requires a reasonable working knowledge of the Rockwell Automation SLC hardware, the MVI46-BDW Module and

More information

MVI94-MCM. Flex I/O Platform Serial Communications Modbus Communication Module USER MANUAL

MVI94-MCM. Flex I/O Platform Serial Communications Modbus Communication Module USER MANUAL MVI94-MCM Flex I/O Platform Serial Communications Modbus Communication Module USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have

More information

Allen-Bradley DF1 Driver PTC Inc. All Rights Reserved.

Allen-Bradley DF1 Driver PTC Inc. All Rights Reserved. 2017 PTC Inc. All Rights Reserved. 2 Table of Contents Allen-Bradley DF1 Driver 1 Table of Contents 2 Allen-Bradley DF1 Driver 5 Overview 5 Cable Connections 6 Channel Setup 7 Channel Properties - General

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly. August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual (Version 1.01) PAGE:1

More information

P3-SCM. General Specifications

P3-SCM. General Specifications General Specifications Module Type Modules per Base Modules per Group I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to

More information

MVI R. User Manual. SLC Platform. Siemens 3964R Protocol

MVI R. User Manual. SLC Platform. Siemens 3964R Protocol MVI46-3964R SLC Platform User Manual June 08, 2006 Please Read This Notice Successful application of this module requires a reasonable working knowledge of the Rockwell Automation SLC hardware, the MVI46-3964R

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU319F-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT

More information

IntesisBox Modbus Server - Honeywell XLS 80

IntesisBox Modbus Server - Honeywell XLS 80 IntesisBox Server - Honeywell XLS 80 Gateway for integration of Honeywell XLS 80 fire panels into (RTU and TCP) enabled control systems. Integrate your Honeywell fire panels into your master device or

More information

DeltaV SD Plus Controller

DeltaV SD Plus Controller August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls

More information

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec PROFIBUS DP / Modbus TCP Gateway EP-321MP User Manual REV 1.2 Sibotech Automation Co., Ltd Technical Support: 021-5102 8348 E-mail:support@sibotech.net Catalog 1 Product Overview... 4 1.1 General...4 1.2

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION ICP PANEL-TEC MICROBRIDGE INSTALLATION AND OPERATION GUIDE MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION Revision History Revision Date Author Comments 000 3 May 2010 David Walker Initial release.

More information

Industrial Protocol Gateway

Industrial Protocol Gateway PG5908A/PG5916A Series Industrial Protocol Gateway Feature Highlights Compliant with IEC 61850- and IEEE 161 Power Substation Standards 8 or 16-port RS-22/22/85, baud rate up to 921.6 Kbps Isolated redundant

More information

PLX51-DL USER MANUAL. Data Logger Data Storage Module. April, 2018

PLX51-DL USER MANUAL. Data Logger Data Storage Module. April, 2018 PLX51-DL Data Logger Data Storage Module April, 2018 USER MANUAL Page 2 CONTENTS 1. Preface... 7 1.1. Introduction to the Data Logger... 7 1.2. Features... 8 1.3. Additional Information... 9 2. Installation...

More information

MVI69L-MBS. CompactLogix Platform Modbus Serial Lite Communication Module USER MANUAL

MVI69L-MBS. CompactLogix Platform Modbus Serial Lite Communication Module USER MANUAL MVI69L-MBS CompactLogix Platform Modbus Serial Lite Communication Module USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions,

More information

VPGate Manual PROFIBUS to serial

VPGate Manual PROFIBUS to serial VPGate Manual PROFIBUS to serial Important information Purpose of the Manual This user manual provides information how to work with the VPGate PROFIBUS to serial. Document Updates You can obtain constantly

More information

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CC 03, Commander Compact (603-1CC21) Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:

More information

AC 800M for Compact Product Suite Outline of all modules

AC 800M for Compact Product Suite Outline of all modules DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose

More information

MVI46-MBP. SLC Platform Modbus Plus Communication Module. User Manual

MVI46-MBP. SLC Platform Modbus Plus Communication Module. User Manual MVI46-MBP SLC Platform User Manual Please Read This Notice Successful application of this module requires a reasonable working knowledge of the Rockwell Automation SLC hardware, the MVI46-MBP Module and

More information

PLX32-EIP-MBTCP-UA. Multi-Protocol Gateway USER MANUAL

PLX32-EIP-MBTCP-UA. Multi-Protocol Gateway USER MANUAL PLX32-EIP-MBTCP-UA Multi-Protocol Gateway USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products. If you have suggestions, comments, compliments

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

CLVM Driver CLV Command Language Module. Table of Contents

CLVM Driver CLV Command Language Module. Table of Contents CLVM Driver CLV Command Language Module CLVM Table of Contents 1 Introduction... 3 1.1 General Specifications... 3 1.2 Resources... 3 2 Functionality... 4 2.1 Data Flow... 4 2.1.1 Receive Data... 5 2.1.2

More information

PLX51-DF1-MSG. DF1 Messenger DF1 to EtherNet/IP TM Messenger USER MANUAL

PLX51-DF1-MSG. DF1 Messenger DF1 to EtherNet/IP TM Messenger USER MANUAL PLX51-DF1-MSG DF1 Messenger DF1 to EtherNet/IP TM Messenger USER MANUAL December, 2017 CONTENTS 1. Preface... 5 1.1. Introduction to the PLX51-DF1-MSG... 5 1.2. Features... 6 1.3. Architecture... 7 1.4.

More information

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21. 0-CC 0-CC Order number 0-CC 0-CC Figure Type CC 0, Commander Compact CC 0DP, Commander Compact, PROFIBUS-DP slave General information Note - - Features x 0 characters, x 0 characters, Integrated PLC-CPU,

More information

I IA CE SE R&D SD 3. SIPLUS RIC IEC on S7. Interoperability list V1.3

I IA CE SE R&D SD 3. SIPLUS RIC IEC on S7. Interoperability list V1.3 I IA CE SE R&D SD 3 SIPLUS RIC IEC on S7 Interoperability list V1.3 Contents Interoperability list I IA CE SE R&D SD 3 1. IEC870-5-101... 3 1.1. General Information... 3 1.2. Device function... 3 1.3.

More information

Features and Benefits. Certifications

Features and Benefits. Certifications MGate 5111 Series 1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus, PROFINET, EtherNet/IP, and PROFIBUS Supports PROFIBUS DP V0 slave

More information