Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB

Size: px
Start display at page:

Download "Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB"

Transcription

1 User Guide Viper-12A S E R I E S Westermo Teleindustri AB X1 X5 X9 ON USB RSTP FRNT CON ON USB RSTP FRNT CON X4 X1 X2 X V X2 X3 X V 1000BASE-T 1000BASE-T X5 X9 X6 X10 X7 X11 X8 X12 X6 X10 X7 X11 X8 X12 ON USB RSTP FRNT M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft CON X1 X2 X3 X V M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft 1000BASE-T X5 X9 X6 X10 X7 X11 X8 X12 M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft 12 port Ethernet M12 switch

2 Software tools Related software tools are available in the folder software tools under technical support on the Westermo website. Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at License and copyright for included Free/Libre Open Source Software This product includes software developed by third parties, including Free/Libre Open Source Software (FLOSS). The specific license terms and copyright associated with the software are included in each software package respectively. Please visit the product homepage for more information. Upon request, the applicable source code will be provided. A nominal fee may be charged to cover shipping and media. Please direct any source code request to your normal sales or support channel

3 Safety! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Also check chapter EN mounting notes. The unit has no internal fuse and should be connected via an external fuse. The fuse should be calculated in accordance with the rated current. Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from all power supply.! WARNING Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources. Be aware of that the surface of this unit may become hot. When this unit is operated at high temperatures, the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL To reduce the risk of fire: 1. Use only No. 21 AWG or larger power cable 2. Use only No. 26 AWG or larger telecommunication line cord

4 Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations: Do not attempt to dissassemble the unit. There are not any user serviceable parts inside. Do not drop, knock or shake the unit. Rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not expose the unit to any kind of liquid (water, beverages, paint etc), unless all connectors are connected or fitted with protective caps (delivered with the unit), tightened to the specified torque. Connected cables must have the appropriate ingress protection code. Do not use or store the unit in dusty or dirty areas, unless all connectors and the ventilation membrane are sufficiently protected. Do not cover or bring mechanical force to the ventilation membrane on the back of the unit. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. Environmental protection Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice

5 Agency approvals and standards compliance Type Climate EMC Mechanical (Shock and vibration) Insulation (Coordination and test) Fire protection FCC Part Notice: Approval / Compliance EN 50155/IEC class TX, Railway applications - Electronic equipment used on rolling stock IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car electronic equipment EN , Immunity industrial environments EN , Emission industrial environments EN /IEC , Railway signaling and telecommunications apparatus EN /IEC Railway applications Rolling stock apparatus Tested and verified for Class S1, DB EMC Regulation 06, Commodity team Radio compatibility in VDB Rev 1.0 (Shunting Radio). Compliant with SBB requirements.. Tested and verified for Class S1, ÖBB Radio compatability in near field in accordance with ÖBB-Infrastructure Edition 4, Revision 14 (Shunting Radio). Tested and verified for FCC part 15 EN category 1, class A EN g, 30 ms EN , Railway applications Insulation coordination EN 50155/IEC 60571, Railway applications - Electronic equipment used on rolling stock EN , Fire protection on railway vehicles This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful inter ference to radio communications. Operation of this equipment in a residental area is likely to cause harmful interference in which case the user will be requied to correct the interference at his own expense

6 Declaration of Conformity Westermo Teleindustri AB Declaration of Conformity The manufacturer Westermo Teleindustri AB SE Stora Sundby, Sweden Type of product Model 1 12-port managed Ethernet M12 Switch Viper-x12A 12-port managed Ethernet M12 Switch with 3Gbps ports Viper-x12A-T3G 12-port managed Ethernet M12 Switch with 5 Gbps ports Viper-x12A-T5G is in conformity with the following EU directive(s). No Short name 2014/30/EU Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) References of standards applied for this EU declaration of conformity. No Title Issue EN Railway applications Electromagnetic compatibility Rolling stock Apparatus EN Railway applications Electromagnetic compatibility Emission and immunity 2015 of the signaling and telecommunications apparatus EN Electromagnetic compatibility - Generic standards - Immunity for industrial 2005 environments EN Electromagnetic compatibility - Generic standards - Emission standard for industrial environments A1:2011 EN Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances 2012 Pierre Öberg Technical Manager 10 th February Model Differences: x = 1 or 2 and indicates Software Class Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S Stora Sundby Eskilstuna Sweden Int Int

7 Type tests and environmental conditions Environmental phenomena Basic standard Description Test levels ESD EN Enclosure Contact: ±6 kv Air: ±8 kv Fast transients EN Power port ±2 kv Signal ports ±2 kv Earth port ±2 kv Surge EN Power port L-E: ±2 kv, 42Ω, 0.5 μf, 1.2/50 μs L-E: ±0.5 kv, 12Ω, 9 μf, 1.2/50 μs L-L: ±2 kv, 42Ω, 0.5 μf, 1.2/50 μs L-L ±0.5 kv, 2Ω, 18 μf, 1.2/50 μs Ethernet ports L-E: ±2 kv, 2 Ω Pulsed magnetic field EN Enclosure 300 A/m Radiated RF immunity EN Enclosure 20 (80 MHz 2 GHz) 10 (2 6 GHz) 1 khz sine, 80% AM Conducted RF immunity EN Power port 10 V, 80% AM, 1 khz; ( ) MHz Ethernet ports 10 V, 80% AM, 1 khz; ( ) MHz Earth port 10 V, 80% AM, 1 khz; ( ) MHz Radiated RF emission CISPR Enclosure Class A ( MHz) ANSI C63,4 Class A ( MHz) (FCC Part 15) Conducted RF emission CISPR Power port Class A Ethernet ports Class B Dielectric strength EN Power port ±2250 V, 1 min to all other ports Fast Ethernet ports ±2250 V, 1 min* to all other ports Gbps Ethernet ports ±2250 V, 1 min* to all other ports Environmental Temperatures EN Operating 40 to +70 C ( 40 to +158 F)** EN Storage and transport 55 to +85 C ( 67 to +185 F) Humidity EN Operating 5 to 95% relative humidity Storage and transport 5 to 95% relative humidity Altitude Operating m / 70 kpa Service life Operating 15 years MTBF Viper-x12A: 1: 557,000 hours Viper-x12A-T3G: 1: 549,000 hours 2: 561,000 hours 1: MIL-C217F2, GB, 25 C (+77 F) 2: IEC Viper-x12A-T5G: 1: 544,000 hours Vibration IEC Operational 2g rms Hz, 5 sweeps (sine) IEC Non-operating long m/s² rms Hz, 5 hours (random) life simulation Shock IEC Operating 10 g, 30 ms, half sine 20 g, 11 ms, saw tooth Enclosure EN Zinc Fire enclosure Dimension W x H x D See "Dimensions" chapter for details With connectors Weight 1.4 kg Degree of protection EN Enclosure IP67*** Cooling Convection * ±750 V after damp heat, according to EN ** Refer to Safety section regarding touch temperature *** Provided all connectors are connected with IP67 cabling or fitted with protective caps (delivered with the unit), tightened to the specified torque

8 Description Designed for harsh industrial environments The Viper-12A series is a series of managed 12 port switches optimised for the needs of the railway rolling stock market. Gbps ports cope with high bandwidth devices such as access points and NVRs (Network Video Recorders). The Viper is designed to withstand the tough environment on-board trains, exposing the switch to constant vibration, extreme temperatures, humidity and a demanding electrical environment. A GORE-TEX membrane prevents internal condensation. Threading integrated in chassis provides for additional vibration resistance. High-level isolation between all interfaces enables direct connectivity to vehicle auxiliary power and protects against overvoltage and flashover. IP67 protection prevents ingress of water and dust. An overall optimised design results in an extremely compact package in combination with very high MTBF for easy integration and low lifecycle cost. Thorough type testing at independent labs certify the compliance to a wide range of standards, not least EN 50155, where the highest class is achieved in all aspects. The state-of-the-art Westermo production facility ensures the quality of each individual unit, e.g. through temperature cycling burn-in testing. The WeOS operating system offers an extensive suite of IP networking features for resilient and flexible networks, e.g. the FRNT ring protocol with very fast failover on 100 Mbps as well as Gbps ports. The powerful layer 3 routing capability is very useful for separating networks in complex applications. The backup device accessory matches the Viper in robustness and offers easy configuration update and backup. Meeting the requirements of the railcar market, the Viper is very well suited for deployment in any other application with severe operating conditions and tough environments, for instance in the mining industry. Product models All switches are managed. Viper x12a is used when referring to both models 112A and 212A. Art.no Model Layer Gbps ports Viper-112A Viper-212A Viper-112A-T3G Viper-212A-T3G Viper-112A-T5G Viper-212A-T5G

9 Interface specifications, Power port Rated voltage Operating voltage Rated current Rated frequency Inrush current, I²t Startup current* Polarity Redundant power input Isolation to Connection 24 to 110 V 16.8 to 143 V (14.4 to 154 V for 100 ms) Max 580 ma at 24 V, max 140 ma at 110 V 105 ma²s at 24 V, 32 ma²s at 110 V Max 840 ma at 16.8 V, Reverse polarity protected Yes ±2250 V to all other ports 4 pin male M12 A-coded connector, recommended Westermo cable: for 1.5 m for 5 m Cable size M12, recommended cable area 0.5 mm² (minimum 0.25 mm²), cable dimensions depend on choice of M12 connector * External supply current capability for proper start-up 100 Mbps ports Electrical specification IEEE std Data rate Duplex Circuit type Transmission range Isolation to Connection Shielded cable Conductive chassis 10 Mbps, 100 Mbps, manual or auto Full or half, manual or auto TNV-1 Up to 150 m with CAT5e cable or better ±2250 V to all other ports* 4 pin M12 D-code, auto MDI/MDI-X, use Westermo cable M12-M12 1 m M12-M12 5 m RJ45-M12 1 m RJ45-M12 5 m Required Yes FRNT reconfiguration time Typically below 20 ms 100 Mbps ports are: X1-X12 on Viper -x12a X1-X3, X5-X7, X9-X11 on Viper-x12A-T3G X1, X5-X7, X9-X11 on Viper-x12A-T5G * ±750 V after damp heat, according to EN

10 Gbps ports Electrical specification IEEE std Data rate Circuit type Connection Transmission range Isolation to Connection Shielded cable 10 Mbps, 100 Mbps, 1000 Mbps, manual or auto TNV-1 8 pin M12 X-code Up to 100 m with CAT5e cable or better ±2250 V to all other ports* 8 pin M12 X-code Required FRNT reconfiguration time Typically below 20 ms Gbps ports are: X4, X8, X12 on Viper-x12A-T3G X2-4, X8, X12 on Viper-x12A-T5G * ±750 V after damp heat, according to EN USB port Electrical specification Data rate Maximum supply current Circuit type Isolation to USB 2.0 host interface Up to 480 Mbps (high-speed mode) 500 ma SELV Ethernet and ports: ±2250 V No isolation to CON or chassis Connection 5 pin M12 female A-code, use Westermo USB plug Console port Electrical specification Data rate Data format Circuit type Isolation to RS kbit/s 8 data bits, no parity, 1 stop bit, no flow control SELV Ethernet and ports: ±2250 V No isolation to USB or chassis Connection 5 pin M12 female B-code, use Westermo cable (serial port) or (USB)

11 Location of interface ports and LED indicators LED indicators 100 Mbps connection USB connection Console connection ON RSTP FRNT USB CON X1 X5 X9 X2 X V X4 X8 1000BASE-T X6 X10 X7 X11 X12 M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft Illustrated by a Viper-x12A-T5G Protective earth connection connection Gbps connection

12 Pin number No 1 No 2 Connector pinout Power Signal No 3 -COM 3 4 No 4 -COM Viper-x12A supports redundant power connection. The positive inputs are +1 and +2, the negative input for both supplies are -COM. Pin number No 1 No 2 No 3 No 4 No 5 CON Signal NC TX RX NC GND Pin number No 1 No 2 No 3 No 4 No 5 USB Signal DN VBUS NC DP GND Pin number No 1 No 2 No Mbps Ethernet Signal TD+ RD+ TD No 4 RD MDI, MDI-X and auto MDI/MDI-X modes are supported. The table shows signals in MDI mode. Pin number Gbps Ethernet Signal 1 DA+ 2 DA 3 DB+ 4 DB 5 DD+ 6 DD

13 Connection to console port The console port can be used to connect to the CLI (Command Line Interface). The following steps needs to be taken 1. Connect the serial diagnostic cable (use Westermo cable (serial port) or (USB) to the console port. 2. Connect cable to your computer serial port. 3. Use a terminal emulator and connect with correct speed and format (115200, 8N1) to the assigned port. For more information about the CLI, see the WeOS Management Guide. Connection to USB port The USB port can be used to copy configuration and log files to/from the switch. Connect the USB plug (use Westermo USB plug ) to the USB port. For more information about the CLI, see the WeOS Management Guide

14 LED Indicators LED Status Description ON OFF Unit has no power. GREEN RED BLINK All OK, no alarm condition. RSTP OFF RSTP disabled. GREEN BLINK Alarm condition, or until unit has started up. (Alarm conditions are configurable, see ''WeOS Management Guide''). Location indicator ("Here I am!"). Activated when connected to WeConfig Tool, or upon request from Web or CLI. RED BLINK during boot indicates pending cable factory reset. RSTP enabled. Unit elected as RSTP/STP root switch. FRNT OFF FRNT disabled. GREEN RED BLINK FRNT OK. FRNT Error. Unit configured as FRNT Focal Point. OFF Unit has no power. X1 to X12 GREEN RED OFF GREEN GREEN FLASH YELLOW Power OK. Power OK on 1 and 2. Power failure on 1 or 2. No Link. Link established. Data traffic indication. Port alarm and no link, or port is set in blocking state by link redundancy protocol. ON RSTP FRNT USB CON X1 X5 X9 X2 X V X4 X8 1000BASE-T X6 X10 X7 X11 Illustrated by a Viper-x12A-T5G X12 M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft

15 Wall mounting There are four 7 mm bores intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and stable surface. ON X1 X5 X9 RSTP FRNT USB CON X2 X V X4 X8 1000BASE-T X6 X10 X7 X11 X12 M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft Connection of cables Recommended tightening torque for the M12 connectors: 0.6 Nm Note that unused connectors must be covered by a protective cap (delivered with the unit), tightened to the specified torque, in order to fulfill the specified ingress protection code. When connecting the power cable, ensure that the pins are connected correctly before tightening the power cable to the unit. Removal Disconnect all cables and unscrew the unit from the wall. Time for replacement < 10 minutes. Cooling This unit relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Hot surface Be aware of that the surface of this unit may became hot. EN mounting notes Two Viper units can be mounted together and as a single interior non-listed group in the sense of EN definitions. For multiple units, the spacing requirements for interior non-listed groups must be met

16 Getting started This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit. WeConfig WeConfig is a Network configuration management tool (NCM) made for commissioning and maintenance of components in a network. Web Configuration of the unit using the web browser. CLI Configuration of the unit via the Command Line Interface. If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions. For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide. Factory default IP address: (and DHCP client) Netmask: Gateway: Disabled Note! If you are not sure about the subnet consult your network administrator. Configuration Configure the unit via web browser The unit can easily be configured via a web browser. Open the link in your web browser, and you will be prompted with a login screen, where the default settings for username and password are: Username: admin Password: westermo Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII ); 'Space' is not a valid password character

17 Reference documents Type Description Document number Management Guide Westermo OS Management Guide Cable factory reset It is possible to set the unit to factory default settings by using two standard Ethernet M12 cables. 1. Power off the switch and disconnect all Ethernet cables. 2. Connect one Ethernet cable between Ethernet ports X5 and X10 and the other between Ethernet ports X6 and X9. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable not a cross-over cable when connecting the ports. 3. Power on the unit. 4. Wait for the unit to start up. Check that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal. Go ahead with factory reset: Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process, and the unit will restart with factory default settings. Skip the factory reset: To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging any of the Ethernet cables. The switch will conduct a normal boot with the existing settings

18 Dimensions Measurements are stated in millimetres

19

20 Westermo SE Stora Sundby, Sweden Tel Fax Sales Units Westermo Data Communications China France Germany North America Singapore Sweden United Kingdom Other Offices For complete contact information, please visit our website at or scan the QR code REV. C Westermo Teleindustri AB, Sweden

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB. X9 X15 X16 X17 X10 X11

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB.  X9 X15 X16 X17 X10 X11 User Guide 6641-22531 REV. C Viper 20A Series Westermo Teleindustri AB X3 X9 X15 X3 X9 X15 X1 X2 X4 X5 X1 X2 X10 X11 X4 X5 X16 X17 X10 X11 X16 X17 ON RSTP FRNT DC USB CON 24-110 V DC X6 X7 X8 ON USB RSTP

More information

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB.   10/100 BASE-TX LINK DC1 X1 X1 DC2 User Guide 6641-2280 DDW-002-B1 Westermo Teleindustri AB 10/100 BASE-TX LINK DC1 X1 X1 DC2 LINK STATUS ACTIVITY LINK MASTER ON POWER M12 Torque 0,6±0,1Nm / 0,45±0,1 lbft EN 50155 Ethernet Broadband Bridge

More information

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage. User Guide 6641-2223 RedFox R A I L Westermo Teleindustri AB Ethernet switch and router approved for railway usage www.westermo.com Software tools Related software tools are available in the folder software

More information

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch. User Guide 6643-2213 WeOS Lynx L110 / L210 Westermo Teleindustri AB Industrial Ethernet 10-port Switch www.westermo.com Safety! Warning Do not open connected unit. Hazardous voltage may occur within this

More information

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire. User Guide 6611-2002 TD-29 DC Westermo Teleindustri AB FSK-modem Multidrop 2-wire www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law,

More information

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB.   X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4 User Guide 6641-2241 Viper-12 s e r i e s Westermo Teleindustri AB X1 X5 X9 SRV 1 X2 SRV 2 X3 X6 X10 X7 X11 DC X4 X8 X12 X1 X5 X9 ON USB RSTP FRNT X2 X3 X6 X10 X7 X11 CON DC X4 X8 X12 12-port Ethernet

More information

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch. User Guide 6643-2213 WeOS Lynx L110 / L210 Westermo Teleindustri AB Industrial Ethernet 10-port Switch www.westermo.com Safety! Warning Do not open connected unit. Hazardous voltage may occur within this

More information

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch. User Guide 6643-2230 WeOS Lynx DSS L105-S1/L205-S1 Westermo Teleindustri AB Industrial Ethernet 5-port Device Server Switch www.westermo.com Software tools Related software tools are available in the folder

More information

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch. User Guide 6643-2240 WeOS Lynx DSS L106-S2/L206-S2 Westermo Teleindustri AB Industrial Ethernet 6-port Device Server Switch www.westermo.com Software tools Related software tools are available in the folder

More information

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender. User Guide 6642-22402 WeOS DDW-226 WOLVERINE SERIES Westermo Teleindustri AB Industrial Ethernet SHDSL extender www.westermo.com Software tools Related software tools are available in the folder software

More information

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender. User Guide 6642-22005 DDW-220 WOLVERINE SERIES Westermo Teleindustri AB DDW-220 Industrial Ethernet SHDSL extender www.westermo.com Software tools Related software tools are available in the folder software

More information

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch. User Guide 6643-2220 WeOS Lynx DSS L108 / L208-F2G-S2 Westermo Teleindustri AB Industrial Ethernet 8-port Device Server Switch www.westermo.com Safety! Warning Do not open connected unit. Hazardous voltage

More information

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender. User Guide 6621-2214 DDW-120 Westermo Teleindustri AB Industrial Ethernet SHDSL Extender www.westermo.com Software tools Related software tools are available in the folder software tools under technical

More information

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch. User Guide 6644-2214 SDW-500 S E R I E S Westermo Teleindustri AB Industrial Ethernet 5-port Switch www.westermo.com Software tools Related software tools are available in the folder software tools under

More information

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch. User Guide SDW-500 S E R I E S 6644-2211 Westermo Teleindustri AB 2004 REV.A Industrial Ethernet 5-port Switch www.westermo.com Contents 1. Description... 3 2. Safety... 4 3. Approvals... 4 3.1 Declaration

More information

Wolverine DDW DDW Industrial Ethernet Extender WeOS

Wolverine DDW DDW Industrial Ethernet Extender WeOS www.westermo.com Wolverine DDW-142-485 DDW-242-485 Industrial Ethernet Extender WeOS 2 6642-22511 General information Legal information The contents of this document are provided as is. Except as required

More information

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card. User Guide 6130-2200 RV-07B Westermo Teleindustri AB 19 rack system PS-20 Power card www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable

More information

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics Redundant Ring Ethernet Extender High Speed Ethernet extension over copper The is an Industrial Ethernet SH extender with support for redundant rings. The redundant protocol can be used either on the SH

More information

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide User Guide 6643-2213 WeOS Lynx L110 / L210 Westermo Teleindustri AB Industrial Ethernet 10-port Switch www.westermo.com License Information This device contains public available software which is under

More information

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch. User Guide 664-0 WeOS RedFox Industrial s e r i e s Westermo Teleindustri AB Industrial Routing Switch www.westermo.com License Information This device contains public available software which is under

More information

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller. AD-01 M-BUS Adapter Industrial adapter, M-bus, Repeater, Converter and zone controller www.westermo.com 2 6612-2202 General information Legal information The contents of this document are provided as is.

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485 LV/HV INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG MANUEL D INSTALLATI Westermo Teleindustri AB 2004 REV. C Galvanic Isolation Transient Protection Balanced Transmission CE Approved RS-422/485

More information

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch. User Guide 6643-2220 WeOS Lynx DSS Westermo Teleindustri AB Industrial Ethernet Device Server Switch www.westermo.com License Information This device contains public available software which is under the

More information

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender. User Guide 6621-2202 DDW-100 Westermo Teleindustri AB Industrial Ethernet SHDSL Extender www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable

More information

RedFox Industrial Series

RedFox Industrial Series www.westermo.com RedFox Industrial Series Industrial Routing Switch WeOS 66-0 General information Legal information The contents of this document are provided as is. Except as required by applicable law,

More information

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender. User Guide 6621-2202 DDW-100 Westermo Teleindustri AB Industrial Ethernet SHDSL Extender www.westermosales.com Legal information The contents of this document are provided as is. Except as required by

More information

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch. User Guide 66-0 WeOS RedFox Industrial S E R I E S Westermo Teleindustri AB Industrial Routing Switch www.westermo.com Software tools Related software tools are available in the folder software tools under

More information

User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router.

User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router. User Guide 6623-2232 BRD-355 Westermo Teleindustri AB Industrial ADSL/VDSL Router www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law,

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm 800xA Networks NE801 User Manual Power and productivity for a better worldtm 800xA Networks NE801 User Manual NOTICE This document contains information about one or more ABB products and may include a

More information

Industrial Routing Switch

Industrial Routing Switch Industrial Routing Switch RFI-14-F4G The RedFox is a high performance industrial Ethernet switch with enhanced routing functionality, in a single robust box. A single RedFox allows you to build cost effective,

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

AO523 Analog Input Module

AO523 Analog Input Module Ordering Data DATA SHEET AO523 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 200 R0001 1SAP 450 200 R0001 AO523, analog output module, 16 AO, U/I, 12 bits

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

MCW-211-F1G-T1G. Industrial Ethernet Media Converter. MCW-211-F1G-T1G Industrial Ethernet Media Converter www.westermo.com 2 6645-2211 General information Legal information The contents of this document are provided as is. Except as required by applicable

More information

Ethernet Extender with serial support DDW-226

Ethernet Extender with serial support DDW-226 Ethernet Extender with serial support DDW-226 High Speed Ethernet extension over copper The DDW-226 is an Industrial Ethernet SHDSL extender with support for redundant rings. The redundant protocol can

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Industrial Routing Switch

Industrial Routing Switch Industrial Routing Switch RFI-10-F4G-T4G The RedFox is a high performance industrial Ethernet switch with enhanced routing functionality, in a single robust box. A single RedFox allows you to build cost

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

AX522 Analog Input/Output Module

AX522 Analog Input/Output Module Ordering Data DATA SHEET AX522 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 000 R0001 1SAP 450 000 R0001 AX522, analog input/output module, 8 AI

More information

TN-5308 Quick Installation Guide

TN-5308 Quick Installation Guide TN-5308 Quick Installation Guide Moxa ToughNet Switch Edition 6.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

ODW-621 Fibre Optic Modem

ODW-621 Fibre Optic Modem User Guide 6650-2222 ODW-621 Fibre Optic Modem Westermo Teleindustri AB Industrial Converter Serial RS-232 to fibre optic link Point-to-point applications www.westermo.com Legal information The contents

More information

AI531 Analog Input Module

AI531 Analog Input Module Ordering Data DATA SHEET AI531 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 600 R0001 AI531, analog input module, 8 AI, U/I/Pt100, TC, 15 bits + sign, 4-wires

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

ODW-622 Fibre Optic Modem

ODW-622 Fibre Optic Modem User Guide 6650-2233 ODW-622 Fibre Optic Modem Westermo Teleindustri AB Industrial Converter RS-232 to Fibre Optic Link. Repeater, line and redundant ring www.westermo.com Legal information The contents

More information

AX521 Analog Input/Output Module

AX521 Analog Input/Output Module Ordering Data DATA SHEET AX521 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 100 R0001 1SAP 450 100 R0001 AX521, analog input/output module, 4 AI,

More information

Safety Standards. Model Number:

Safety Standards. Model Number: PMC Highlights & Features Universal AC input range from 85Vac to 264Vac without power de-rating High operating ambient temperature, > 60 o C de-rating power High MTBF > 700,000 hrs. as per Telcordia SR-332

More information

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

CI504 PROFINET Communication Interface Module

CI504 PROFINET Communication Interface Module Ordering Data DATA SHEET CI504 PROFINET Communication Interface Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 221 300 R0001 1SAP 421 300 R0001 CI504-PNIO, PROFINET Bus Module

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy Trackside Networks Solutions for Railway and Trackside Applications Robust Industrial Data Communications Made Easy Industrial Data Communications Heritage Produced by: Westermo Teleindustri AB Photo:

More information

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

CM589 PROFINET Communication Module

CM589 PROFINET Communication Module Ordering Data DATA SHEET CM589 PROFINET Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 172 900 R0011 1SAP 372 900 R0011 1SAP 172 900 R0111 1SAP 372 900 R0111

More information

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN Highlights & Features Full corrosion resistant Aluminium chassis Suitable for 24V system up to 40A Built-in diagnostic monitoring for DC OK, Discharge and Battery Fail by relay contacts LED indicator for

More information

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 80.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

CM592 PROFIBUS Communication Module

CM592 PROFIBUS Communication Module Ordering Data DATA SHEET CM592 PROFIBUS Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 200 R0001 1SAP 373 200 R0001 CM592-DP, communication module PROFIBUS

More information

CM579-PNIO PROFINET Communication Module

CM579-PNIO PROFINET Communication Module Ordering Data DATA SHEET CM579-PNIO PROFINET Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 170 901 R0101 1SAP 370 901 R0101 CM579-PNIO, PROFINET communication

More information

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch. User Guide 6640-2001 Lynx SERIES Westermo Teleindustri AB Industrial Ethernet 8-port Switch www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

EH-RIO IP67 Profibus-DP I/O modules

EH-RIO IP67 Profibus-DP I/O modules Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP

More information

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

DC541 Digital Input/Output Module

DC541 Digital Input/Output Module Ordering Data DATA SHEET DC541 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 270 000 R0001 1SAP 470 000 R0001 DC541-CM, digital input/output module,

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 59,5mm Suitable for mounting in domestic installation panels Low output ripples and spikes Fully compliance to ECO-Standard

More information

CM589 PROFINET Communication Module

CM589 PROFINET Communication Module Ordering Data DATA SHEET CM589 PROFINET Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 172 900 R0011 1SAP 372 900 R0011 1SAP 172 900 R0111 1SAP 372 900 R0111

More information

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Household appliance approvals IEC/EN 60335-1 4kV Electrical Fast Transient / Burst Universal AC input voltage

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description PMC Highlights & Features Universal AC input range from 85Vac to 264Vac without power de-rating Full Aluminium casing for lightweight and corrosion resistant handling Conform to harmonic current IEC/EN

More information

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy Trackside Networks Solutions for Railway and Trackside Applications Robust Industrial Data Communications Made Easy Industrial Data Communications Heritage Produced by: Westermo Teleindustri AB Photo:

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

DC522 Digital Input/Output Module

DC522 Digital Input/Output Module Ordering Data DATA SHEET DC522 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 240 600 R0001 1SAP 440 600 R0001 DC522, digital input/output module, 16

More information

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter. User Guide 6645-2204 MCW-211 S E R I E S Westermo Teleindustri AB Industrial Ethernet Media Converter www.westermo.com Legal information The contents of this document are provided as is. Except as required

More information

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender. User Guide 6642-22005 DDW-220 Wolverine series Westermo Teleindustri AB DDW-220 Industrial Ethernet SHDSL extender www.westermo.com Legal information The contents of this document are provided as is. Except

More information

Safety Standards. Model Number:

Safety Standards. Model Number: PMC Highlights & Features Universal AC input range from 85Vac to 264Vac without power de-rating Full Aluminum casing for light weight and corrosion resistant handling High MTBF > 700,000 hrs. as per Telcordia

More information

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame* PMT Highlights & Features AC input voltage selectable by switch Full Aluminium casing for light weight and corrosion resistant handling Convection cooling Cold start -20 C at 100% load (200W) Low leakage

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front

More information

RedFox Industrial Rack Series

RedFox Industrial Rack Series www.westermo.com RedFox Industrial Rack Series Industrial Routing Switch Digital In- Digital In+ Status- Status+ WeOS 2 6641-22810 General information Legal information The contents of this document are

More information

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch) PMT Highlights & Features AC input range selectable by switch Full Aluminium casing for light weight and corrosion resistant handling Built-in automatic fan speed control circuit Wide operating temperature

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A PMC Highlights & Features Universal AC input range from 85Vac to 264Vac without power de-rating Full Aluminum casing for light weight and corrosion resistant handling High MTBF > 700,000 hrs. as per Telcordia

More information

Leased-Line Extenders over IP

Leased-Line Extenders over IP SmartNode 2290 Series Leased-Line Extenders over IP Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

MRD-405. Industrial M2M/4G Gateway/Router GSM / GPRS / EDGE / HSDPA / HSUPA / HSPA/ 4G LTE. User Guide Westermo Teleindustri AB

MRD-405. Industrial M2M/4G Gateway/Router GSM / GPRS / EDGE / HSDPA / HSUPA / HSPA/ 4G LTE. User Guide Westermo Teleindustri AB User Guide 6623-2212 MRD-405 Westermo Teleindustri AB Industrial M2M/4G Gateway/Router GSM / GPRS / EDGE / HSDPA / HSUPA / HSPA/ 4G LTE www.westermo.com Legal information The contents of this document

More information

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5. PMC Highlights & Features Universal AC input voltage without power de-rating Full corrosion resistant Aluminium chassis NEC Class 2 power supply and Limited Power Source (LPS) approvals High MTBF > 700,000

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

PSC600-series DC/DC W

PSC600-series DC/DC W PSC600-series DC/DC 300-800 W The PSC600 series convection cooled DC/DC converters has a wide range of input and output combinations. The basic mechanical design is based around the Euro format 6HE 230

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information