Optional Remote Sensors - Connect via RJ12 Standard sensor lengths include 12 and 20. Custom lengths available upon request. Temperature:
|
|
- Hugo Hood
- 5 years ago
- Views:
Transcription
1 RJ Port Sensors RJ Port Sensors Monitored Basic & Optional Remote Sensors - Connect via RJ12 Standard sensor lengths include 12 and 20. Custom lengths available upon request. Recommended Levels for Wiring Closets & Data Centers Temperature: F Airfl ow: Relative to Location Humidity: See ASHRAE Tc9.9 Satellite Switched RT Dew Point: See ASHRAE Tc9.9 Temperature Sensor (RT) Temperature: -40F to 254F Temperature Accuracy: +/- 1.8F from 40F to 122F Precisely monitor hot spots throughout your installation. Resources Educational Brackets Software Environmental RTAF RTAFH Temperature & Airflow Sensor (RTAF) Temperature: -40F to 254F Temperature Accuracy: +/-.9F from 50F to 185F Airfl ow: relative The addition of air fl ow monitoring in this dual sensor allows for trending analysis as modifi cations to your installation are made which may create new air fl ow voids. Temperature, Airflow & Humidity Sensor (RTAFH) Temperature: -40F to 254F Temperature Accuracy: +/-.9F from 50F to 185F Airfl ow: relative Humidity: RH Accuracy +/- 2% RH, Range: 0 to 100 % RH, non-condensing Monitor three environmental conditions in this single cord sensor. Ideal for placement near air intake (coldest/driest conditions) and air exhaust (warmest/moistest conditions). Temperature, Humidity & Dew Point Sensor (RTHD) Temperature: -40F to 254F Temperature Accuracy: +/-.9F from 50F to 185F RTHD Humidity: RH Accuracy +/- 2% RH, Range: 0 to 100 % RH, non-condensing Dew Point: Calculated using data provided by the humidity sensor. Dew Point monitoring in this three-in-one sensor is ideal for wiring closets, satellite or outside plant stations where low temperature objects are exposed to rapid temperature change
2 I/O Port Sensors I/O Port Sensors Optional Remote Sensors - Connect via I/O Port or CCAT (See page 167) Basic & Door Position Sensor Magnetic Switch (RDPS) relative Monitor cabinet door position (open vs. closed) with this magnetic sensor. Set alarms to alert when a secure cabinet has been opened. Standard lengths of 30 & 100 with custom lengths available upon request. Water Sensor (RWS) relative Acts as a conductivity bridge to detect the presence of moisture or water in your facility. Standard 20 cord length with custom lengths available upon request. Smoke Alarm Kit (SA-1) relative Integrate smoke alarm functionality into your system and receive remote alarm notifi cation. Kit features Kidde 1275 with interface module and 5-15P straight-blade plug. Power Fail Monitor (RCP-2-100) relative This sensor is connected directly to your utility power feed to alert you when utility power has been affected. Ideal for down-time prevention when PDUs are connected directly to a UPS. Notifi cation of a possible outage prior to UPS battery exhaustion is critical. (power supply included) Monitored Switched Satellite Environmental Software Brackets Educational Resources
3 I/O Port Sensors I/O Port Sensors Monitored Basic & Water Sensing Cable Kit (WSCK) With the advent of liquid cooling in datacenters, water has become increasingly integrated into the computer room environment. Geist Water Sensing Cable Kits feature detection cables which sense the presence of water along the entire cable length. These kits are ideal for detecting moisture over a wide area such as the perimeter of a group of racks and cabinets. When connected to any Geist units with I/O ports, you can be alerted to potential dangers via or SNMP traps. The WSCK-10 contains a 10 detection cable and the WSCK-40 contains a 40 detection cable. Specifications Resources Educational Brackets Software Environmental Satellite Switched Water Alarm To RacSense To I/O (8715) I/O (8715) Fault Alarm WSCK WATER SENSING CABLE KIT 8700 Interface Box Leader Cable Leak Detection Cable with EOL (end of line) connector 8714 Power Supply, 6 length Connection Wire (Interface Box to I/O port) pack, J Clips Water Sensing Cable Kit Application Interface Box (8700) 6 VDC Power Supply (8714) Leader cable - 15 feet (8701) WSCK WATER SENSING CABLE KIT 8700 Interface Box Leader Cable Leak Detection Cable with EOL (end of line) connector 8714 Power Supply, 6 length Connection Wire (Interface Box to I/O port) pack, J Clips Plenum Rating: CL2P/CMP C(UL) Sheer Strength: >180 lbs. Cut Resistance: >40 lbs. with.005 blade Abrasion Resistance: 60 cycles per UL 719 Connector: 4 pin, 0.96 diameter Operating Environment Temperature: 32º to 167ºF Humidity: 5% to 95% RH, non-condensing Altitude: 10,000 ft. max. Storage: -22º to 185ºF Diameter of cable: not more than 0.25 Weight:.02 lbs/ft Top view of Server room Floor EOL terminator plug Water sensing cable (8704 & 8705) J-clips (8702 & 8703) Additional cable lengths available Leak Detection Cable Leak Detection Cable Leak Detection Cable Leak Detection Cable Non Sensing Cable Non Sensing Cable Non Sensing Cable Non Sensing Cable 166
4 I/O Port Sensors I/O Port Sensors I/O to RJ Remote Sensor Converter (CCAT) This handy accessory enables connection of I/O devices into RJ12 jacks on Geist units. Device is programmed for the specifi c sensor and available for use with Geist I/O remote sensors. Basic & Monitored Power Monitor - I/O Sensors (-48VDCM & 30VDCM) Continuously track the charge of telephone batteries or cell phone system power with -48VDCM or 30VDCM sensors. Designed for telephony battery voltage monitoring and other applications requiring monitoring a DC voltage, these sensors monitor voltage via the I/O inputs on Geist units. Power Over Ethernet (PoE) Power Geist Environmental Monitors and web cameras over Ethernet cable. Power over Ethernet eliminates the need to run 110/220VAC power to wireless access points and other devices on a wired LAN. Installers only need to run a standard CAT5 cable that will carry both data and power to each device. A PoE confi guration consists of two components; an injector and a splitter. The injector takes data from an Ethernet hub and power from a wall outlet and outputs both data and power through a CAT5 cable. The splitter is placed at the end of the CAT5 cable, returning data and power to their respective cables. (POI-2000) PoE Injector (POS-1000) PoE Splitter Environmental RSMINI163 Monitor (-48VDCM) (30VDCM) Internet Switched Satellite Environmental Software Brackets Educational Resources 12VDC, 300mA PoE Splitter CAT5 cable PoE Injector Ethernet POS ' POI VAC power
5 Monitored Basic & Remote Display (RSD2X8) The RSD2X8 local display is connected to a RSM, RCX, RCM, or RCU power strip and then mounted outside the cabinet for ease of viewing user-selected critical data. This device eliminates the need to enter a secure enclosure to see power and environmental monitoring readouts. A 10 RJ type connection cord is included. Satellite Switched Software Environmental RJ12 16-Port Splitter (SPL16) Multiply the power of your Temperature Monitor Plus with this compact 1U 16-port splitter. Designed with four mounting holes for front or rear attachment of the RSMINI-P. Compatible with all Geist units with external ports for environmental monitoring. RJ12 5-Port Splitter (SP-5) Expand the number of sensors connected to your Geist unit with RJ12 sensor ports. Especially ideal for compact units such as the Temperature Monitor Plus. Brackets Resources Educational D-Link Web Enabled Cameras (DCS920) Acquire live video stream via the DCS920 IP enabled web camera. Its small profi le allows for discrete placement inside or outside the cabinet. Geist units interface with various web enabled camera models from a variety of manufacturers including Axis, D-Link, LinkSys and Panasonic. Because this list is continually expanding, please contact customer service for a current list of supported cameras
6 IEC Cord Sets Help minimize cord tangle and increase airfl ow to your installation. Select an ideal length cord set for use with Geist IEC units. Cable Management Kits Conceal unsightly loose cords. Pre-split plastic tubing can be easily cut to the length you need. Kit includes tubing, color-coded labels for easy cord identifi cation and reusable plastic ties for bundling cords. Tiny Temp This handy diagnostic tool can be mounted near hot spots or carried by your technicians for convenient temperature spot checks near high heat producing equipment. Each unit contains a detachable 12 remote temperature sensor for precise placement. The digital display cycles between Fº and Cº readings with an accuracy of + / -.5 Cº. This unit contains a low battery indicator and is powered by two AA batteries (not included), estimated to last one year. Part # Type Description 7349 INPUT /3 SJT Black cord set, 5-15P to C INPUT /3 SJT Black cor set, L6-20P to C INPUT /3 SJT Black cord set, 6-20P to C INPUT /3 SJT Black cord set, L5-20P to C INPUT /3 SJT Black cord set, 5-20P to C PATCH 20 18/3 SJT Black cord set, C-14 to C PATCH /3 SJT Black cord set, C-14 to C PATCH /3 SJT Black cord set, C-20 to C SPLIT-PATCH 6 12/3 SJT Black Y cord set, C-20 to (2) C-19 Part # Description capacity, 10 black capacity, 10 black capacity, 300 black (no plastic ties) TTS-MINI Dimensions 1.72 x3.8 x1.1 (HxWxD) Basic & Monitored Switched Satellite Environmental Software Brackets Educational Resources TTS-1U Dimensions 1.72 x19 x.85 (HxWxD) 19 rack mountable unit - doubles as a filler panel
7 Plug, Outlet and Switch Protection Monitored Basic & Plug-Outs (NPP-1) NEMA Outlet Plugs - Safety Yellow Bright Yellow outlet plugs for 15 Amps and 15/20 Amp 125V NEMA receptacles. Geist Plug-Outs contain an international NO symbol to discourage use of any unused outlets and help prevent circuit overloads. Typically the electrical load for installed PDU s should not exceed 80% of the unit capacity. Satellite Switched ew IEC Plug Shields Restrict access to IEC power outlets with these secure covers which require a specialized tool for removal. Designed to fi t all IEC C-13 or C-19 receptacles. Plug Shield C-13 Plug Shield C-19 Software Environmental Brackets Plug Shield Removal Tool IEC C-13 Retaining Clip (7759) Designed for use with Geist vertical units containing C-13 outlets (excludes RCM-O and RCU-O verticals). Sold individually or in packages of 12 ( ). (8954) Designed for use with Geist vertical units, with a width of 1.85 or greater, containing C-19 or duplex NEMA outlets as well as all outlets on RCM-O and RCU-O verticals. Sold individually or in packages of 6 (8951-6). Note: These clips are designed for use with cordsets sold by Geist. Compatibility varies by cordset manufacturer Resources Educational Switch Cover (SC) Our Geist hinged box Switch Cover protects your power strip from accidental shut down, while allowing the fl exibility of switched power control. The sturdy translucent plastic allows for secure protection and visibility of the switch position. Must be ordered with strips; not fi eld upgradable
8 Custom Metal Blanking Panels To maintain proper airfl ow and prevent air recirculation, Geist offers a variety of cabinet blanking panels. A rack without blanking panels can result in thermal damage due to improper cooling as well as excessive energy consumption and an increased carbon footprint. Each Geist blanking panel is engineered with an overlapping lip (see diagram A) for an improved seal to deliver lower temperature air to the hottest area, the upper third of the cabinet. Part # 1UBP 1UBPSKO 2UBP 3UBP 5UBP 3UCMRS 2URS 1UBPSKO 1UBP 2UBP 3UBP 5UBP Description 1U Blanking panel 1U Blanking panel with sensor knock out 2U Blanking panel 3U Blanking panel 5U Blanking panel PANELS PANELS OVERLAP OVERLAP FOR IMPROVED SEAL FOR IMPROVED SEAL A 4UWR DETAIL A 4U Wall Rack In addition to 4U equipment mounting space, Geist s 19 wall rack features a 1U power strip mounting location at the base of the rack. This single piece rack is manufactured with 16 gauge steel and requires no fi eld assembly. Part # 4UWR Description 4U Wall rack Basic & Monitored Switched Satellite Environmental Software Brackets Educational Resources Rack Shelves Geist s 19 rack shelves are manufactured with 16 gauge steel with edges bent up for maximum strength and equipment support. Part # 2URS 3UCMRS Description 2U Rack shelf Front mount shelf with 10.5 depth 3U Rack shelf Double-sided shelf with overall 20 depth
Environmental Monitor (RSMICRO)
Environmental Monitor (RSMICRO) Monitored Basic & Temperature and humidity are two of the most critical conditions to monitor in computing space. While temperature is often given moderate attention, relative
More informationPower Monitoring (RCX)
Power Monitoring (RCX) Geist s Power Monitoring PDUs provide a comprehensive remote view of your installation s power utilization. In addition to Amps, Volts, Real Power, Apparent Power, Power Factor and
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationPDU - Overview / Non-Intelligent PDU s
PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationRack- and Panel-Mount Power Distribution Units (PDUs)
Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES Power on/off LED indicates whether power is available at the PDU External
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More information20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More information30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More informationSpecification Sheet: HT SERIES
Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationMid-span 802.3af PoE Injector. Installation Guide KPOE-100
Mid-span 802.3af PoE Injector Installation Guide KPOE-100 Doc. 070521 1 (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used
More informationSwitched, Outlet Level Monitoring
Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationRack- and Panel-Mount Power Distribution Units (PDUs)
Spec-00193 Cable and Power Management Power Distribution Units (PDUs) Rack- and Panel-Mount Power Distribution Units (PDUs) FEATURES INDUSTRY STANDARDS UL/cUL 60950 listed UL 1449 (Surge protector models
More informationTechnical Overview CM-5 The Compact Climate Monitor Bundle. Get yours direct at:
Technical Overview CM-5 The Compact Climate Monitor Bundle Get yours direct at: 01491 410913 www.theclimate.co.uk OVERVIEW Bundling five CM-1 Climate Monitors, the CM-5 is a great solution for multiple
More informationANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL
ANI-15115-08SWH PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com
More informationAll power outlet units include 10' power cords, mounting brackets, screws, unit packaging:
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More information316TX-N. Phone: Fax: Web: -
THE INDUSTRIAL NETWORK COMPANY 316TX-N The N-TRON 316TX-N, an unmanaged Industrial Ethernet switch, is designed for use in industrial data acquisition, control, and Ethernet I/O applications. The rugged
More informationModular 8-Port Mid-span Power over Ethernet Injector
Modular 8-Port Mid-span Power over Ethernet Injector KPOE-800-1P KPOE-800-2P Installation Guide DOC.090201 1 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More information16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More informationDVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8
DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all
More informationRCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration RCOBN248-102PH6TL21-D Power Monitoring, Outlet Level 20A, 120/208V WYE, 5.7kW 66 in Vertical Description RCOBN248-102PH6TL21-D provides site managers
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More informationSTANDARD MEDIA CONVERTER SWITCHES
2005. All rights reserved. Black Box Corporation. Black Box Network Services (UK) Ltd 464 Basingstoke Road Reading, berkshire, RG2 0BG Tech Support: 0118 965 6000 www.blackbox.co.uk STANDARD MEDIA CONVERTER
More informationPower Distribution. For technical support call Online catalog available at leviton.com 461
INDEX FLX Series... 463 Switched Series... 464 Metered Series... 465 P1000 Series... 466 5500 & 5505 Series... 467 4500 Series... 468 For technical support call 800-824-3005 Online catalog available at
More informationPower Monitoring in the Data Centre
Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags
More informationLiebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection
Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection Liebert GXT4 UPS, 5kVA-10kVA Systems: Best Protection for Critical Network Applications Today s converged networks require increased availability
More informationE-Series Site Preparation Guide
E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...
More informationPRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading
1/6 CR Series Ceiling Rack Systems with AmbiTILT Equipment Loading General Description AtlasIED, the manufacturing leader of ceiling mounted loudspeakers introduces the new CR Series ceiling-mounted equipment
More informationWIRELESS ENVIRONMENTAL MONITORS
Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. From installation to monitoring in minutes 1 Place wireless
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationKPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC
KPW-T2P25 Industrial IEEE 802.3at High Power PoE Splitter User s Manual DOC.121011-1- (C) 2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any
More information10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual
10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1
More informationTOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models
TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30
More informationTOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown
TOT Series Manual North American and International Models - without optional faceplate Receptacle Panel of International Models, CE model shown North American Models Table of Content 1. Important Safety
More informationIndustrial 1-Port Gigabit 95W Ultra PoE Splitter
Industrial 1-Port Gigabit 95W Ultra Splitter Key Features Interface 2 RJ45 interfaces 1-port + input 1-port output 2 output (4-pin terminal block) 1 12V/24V DIP switch over Ethernet Complies with ultra
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationIndustrial Ultra Power over Ethernet Splitter IPOE-171S
Industrial Ultra Power over Ethernet Splitter IPOE-171S User s Manual Table of Contents 1. Package Contents... 3 2. Product Features... 4 3. Product Specifications... 5 4. Hardware Introduction... 8 4.1
More informationRack 111 Catalog. Designed and Built to Exceed Your Needs.
Designed and Built to Exceed Your Needs. The Open Frame Server Rack is designed to provide users with a customizable solution engineered to meet a diverse set of rack mounting needs. This EIA server rack
More informationCS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)
CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More information6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable
6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable Product ID: IES61002POE The IES61002POE 6-Port Industrial PoE+ switch lets you connect
More informationSNAP Compact Fiber Optic Patch Panel
SNAP Compact Fiber Optic Patch Panel Compact size perfect for limited space enclosures UL Listed 1863 Versatile surface or DIN-Rail mount capability Slide-hinged faceplate aids field termination Patch
More information8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual
8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a
More information1-Port Gigabit Midspan - PoE+ Injector at and 802.3af
1-Port Gigabit Midspan - PoE+ Injector - 802.3at and 802.3af Product ID: POEINJ1GW This Gigabit Power over Ethernet (PoE+) injector supplies power and data connectivity to a Gigabit PoEcompliant device
More informationGigabit PoE Injector Patch Panel
Gigabit PoE Injector Patch Panel 1/4/8/12/16/24 Port Gigabit PoE Injector 1 ~ 24 Port Gigabit PoE Injector Patch Panel 제품사양및모양은제품성능향상을위해예고없이변경될수있습니다 Model Number: GPOE-1-AB 1 Port Gigabit Passive PoE Injector
More informationHP Modular Cooling System: water cooling technology for high-density server installations
HP Modular Cooling System: water cooling technology for high-density server installations technical brief Abstract... 2 Introduction... 2 Data center trends... 2 Increased power demands... 3 Increased
More informationUSER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH
USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before
More informationPS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL
PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31
More informationPDU Solutions. PDU Solutions
Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation
More information317FX-N. Phone: Fax: Web: -
THE INDUSTRIAL NETWORK COMPANY 317FX-N The N-TRON 317FX-N, an unmanaged Industrial Ethernet switch, is designed for use in industrial data acquisition, control, and Ethernet I/O applications. The rugged
More informationThis Gigabit midspan PoE+ injector is a cost-effective alternative to upgrading your existing network switch to a PoE-capable model.
4-port Gigabit midspan - PoE+ injector - 802.3at/af StarTech ID: POEINJ4G This Gigabit midspan PoE+ injector is a cost-effective alternative to upgrading your existing network switch to a PoE-capable model.
More informationIT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...
IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access
More informationIntelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)
Faster. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier
More informationDell MD1280 Storage Enclosure Getting Started Guide
Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
More informationTELCO. Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia
TELCO EDGE SERVER AND CHASSIS Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia Open edge chassis overview Key specifications 3U, 19 mountable (EIA-310 compatible) 130.6 x 440 x 430 mm (H x W x D) 1U and
More informationInstruction Manual Environmental Monitoring Unit. GRSMINI-P, GRSMICRO, GRSMINI163 Firmware Version 3
Instruction Manual Environmental Monitoring Unit GRSMINI-P, GRSMICRO, GRSMINI163 Firmware Version 3 Geist. 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com
More informationOwner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series
Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation
More informationAPS SCALE SERIES DIMENSIONS
APS SCALE SERIES DIMENSIONS 4300 Section page 4 Model APS4300 Recommended Column/Base Combinations 14 Atlas Column 20 Atlas Column 30 Atlas Column Atlas Scale Series Dimensions: 4300 OPTIONS 4300 Section
More informationCOOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments
COOLING SOLUTIONS SmartRack Close-Coupled Cooling for IT Environments Efficient, flexible, manageable cooling reduces costs and simplifies installation. Efficient, flexible, manageable cooling for IT environments
More informationDelivered the Way Yo u Want
SENSAPHONE IMS-4000 Infrastructure Monitoring System Mo nito r What Yo u Want Delivered the Way Yo u Want THE SENSAPHONE IMS-4000 MONITORS AND REPORTS THE INFORMATION THAT YOU NEED TO KNOW: Get critical
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air
More information304TX-N. Phone: Fax: Web:
THE INDUSTRIAL NETWORK COMPANY 304TX-N The N-Tron 304TX is an unmanaged four port Industrial Ethernet Switch. It is housed in a ruggedized DIN-RAIL enclosure and is designed for use in industrial data
More informationHigher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile
More informationUSB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft
USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationINSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.
INSTRUCTION MANUAL DISTRIBUTION UNIT Please read this manual thoroughly before use, and keep it handy for future reference. ISSUE 1 May 2006 LIMITATION OF LIABILITY THE INFORMATION IN THIS PUBLICATION
More informationLCP Hybrid Efficient performance with heat pipe technology
LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative
More informationUSB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1
USB 2.0 SR Extender over one CAT-5 Cable EXT-USB2.0-SR User Manual Version A1 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.
More information1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual
1 10/100TX + 1 100FX w/ 1 PoE Injector Industrial Switch User Manual CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user
More informationInstallation and Maintenance
CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,
More information4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions
4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server
More information308FX2-N. Phone: Fax: Web:
THE INDUSTRIAL NETWORK COMPANY 308FX2-N The N-TRON 308FX2-N, an unmanaged Industrial Ethernet switch, is designed for use in industrial data acquisition, control, and Ethernet I/O applications. The rugged
More information10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual
10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual v1.02 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to
More informationData Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center
Data Center Enclosures Best Practices Maximize the Efficiency of the Enclosure within a Data Center Things to ask before selecting Enclosures: Primary Use Severs or Patching, or both determines size. RMU
More informationTechnical Manual Nova: Cabinet Security Management System (CSMS)
Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova
More informationPower-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features
Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate and Cooling Fan Model: NB141207-40F Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power-Over-
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationPIX 515/515E. PIX 515/515E Product Overview CHAPTER
CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationLNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.
LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with
More informationIP67 Certified 2T2R 5GHz Outdoor Wireless-N Access Point - PoE-Powered 300Mbps a/n WiFi AP
IP67 Certified 2T2R 5GHz Outdoor Wireless-N Access Point - PoE-Powered 300Mbps 802.11a/n WiFi AP Product ID: R300WN22MO5E The R300WN22MO5E Outdoor Wireless Access Point lets you add 5GHz Wireless-N network
More informationHardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationAudio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2
Audio DVI 3GSDI ELR Lite Embedder Extender over one CAT-5 EXT-DVI-1CAT5-SR User Manual Release A2 DVI ELR Lite Extender over one CAT-5 Important Safety Instructions 1. Read these instructions. 2. Keep
More informationInstruction Manual Environmental Monitoring Unit with Output Relays. Watchdog 1400 Series Firmware Version 3
Instruction Manual Environmental Monitoring Unit with Output Relays Watchdog 1400 Series Firmware Version 3 Contents Contents... 2 Specifications... 3 Overview 3 Environmental 3 Electrical 3 Output Relay
More informationDS-1H05 Ethernet-over-Coax Extender. User Manual
DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,
More informationAPC APPLICATION NOTE #74
#74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.
More informationLiebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity
Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today
More informationSMARTONLINE E3 UPS SYSTEMS
SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,
More informationGeist designs and manufactures intelligent hardware and software for the four cornerstones of data center management:
Product Overview Our Mission Geist will be the premier provider of products and services to our customers regardless of industry, product or service setting the standard by which all others are compared.
More informationB&W RearView Camera Installation & Operation
B&W RearView Camera Installation & Operation CA52 (Camera) FOR MORE INFORMATION WWW.STRATEGICVISTA.COM BEFORE OPERATING THIS SYSTEM, PLEASE READ THIS MANUAL THOROUGHLY AND RETAIN IT FOR FUTURE REFERENCE
More information30 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information
SPECIFICATION SHEET specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management of the in-cabinet power usage. This system helps to quickly
More information