Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date
|
|
- Noah Butler
- 5 years ago
- Views:
Transcription
1 ATS-ATP-3405 Page: 1 of 8 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013 Historical Reference Section: Section Name Section Number (i.e., 5.2.1) Revision Affected Explanation of Change Scope 2. A Added not regarding use of facility s SOP when requested Document Control N/A B Review 1. Purpose This document provides instruction for the performance of Room Recovery and Particle Fallout test. 2. Scope This procedure shall be followed by personnel performing cleanroom certifications. Additional testing and or deviation from this SOP shall be agreed upon prior to the start of testing. Note: Facilities Standard Operating Procedures will be followed per client request.
2 ATS-ATP-3405 Page: 2 of 8 3. References 1. Institute of Environmental Sciences Contamination Control Division Recommended Practice IES-RP Testing Cleanrooms 2. International Organization for Standardization ISO Cleanrooms and associated controlled environments - Part 1: Classification of airborne particulates 3. International Organization for Standardization ISO Cleanrooms and associated controlled environments - Part 2: Specifications for testing and monitoring to prove continued compliance with ISO Material Safety Data Sheets (MSDS) located immediately outside the cleanroom. 4. Equipment and Materials Equipment: 2. Aerosol Generator Laskin nozzle compressed air operated DOP/Emery 3000 generator 3. Laser Particle Counter capable of measuring particulate relative to the classification of the room. 4. Witness Plates 5. Microscope 5. Safety 1. Wear proper cleanroom gowning attire as specified by facility SOP or as instructed by facility point of contact. 2. Avoid lifting heavy equipment. Wait for help from another employee prior to lifting any heavy equipment. 3. Avoid reaching while working on a ladder. Move the ladder to ensure proper access to your concern. Do not step on the top two rungs of a step ladder. 4. Refer to manufacturer s safety precautions and Material Safety Data Sheet (MSDS) for appropriate protective equipment and safe handling procedures when using chemicals.
3 ATS-ATP-3405 Page: 3 of 8 6. Responsibility 1. It is the responsibility of the President to maintain this document and oversee these activities. 2. It is the responsibility of the individual(s) performing this task to follow this procedure. 7. Preliminary Operations 1. Collect all materials and equipment necessary to conduct the certification. 2. Ensure all equipment is within calibration prior to the start of use. 3. Wipe down all equipment in accordance with the facility SOP or use a 70% ethanol, 30% water solution unless otherwise instructed by the facility point of contact. 8. Cleanroom Operational Phases Testing may be performed at different stages as characterized by the completeness of the cleanroom installation and operational modes as defined below. Stage 1 Stage 2 Stage 3 NOTE: As-Built-Facility: A cleanroom which is complete and operating with all services connected and functioning, following initial clean down. There is to be no process equipment or operating personnel within the facility. At-Rest-Facility: A cleanroom which is complete and operating. The room is to be fully populated with process equipment staged in a nonoperational mode. There shall be no operating personnel present. Operating Facility: A cleanroom in normal operation fully populated with functioning process equipment and operating personnel. At times it will be necessary to take exception to strict compliance with the aforementioned testing stages. Deviation or interaction among the
4 ATS-ATP-3405 Page: 4 of 8 stages may be required due to availability or operational status of the process equipment. These situations shall be identified and acknowledged as part of the contractual agreement. 9. TEST PROCEDURES AND ACCEPTANCE CRITERIA A. Room Recovery Test 1. Purpose The recovery test is performed to determine whether the cleanroom or clean zone is capable of returning to its specified cleanliness class within a finite time, after being exposed briefly to a source of airborne particulate challenge in the form of a smoke or optional aerosol. This test is not recommended for unidirectional flow rooms. 2. Apparatus A). A smoke generator or suitable alternative aerosol source B). A discrete-particle counter having a minimum sampling flow rate of 1 cfm and particle size discrimination capability of 0.5 um or smaller. 3. Procedure A). Measure the particle counts at a room air return outlet to establish the existing particle concentration level. B). Generate smoke at the air inlet to the room until a particle count at the outlet is substantially above the room s at-rest level. Turn the generator off. C). Record the particle count for a 6-second period each minute, until the cleanliness level at the outlet is restored to the original condition. Record this decay time.
5 ATS-ATP-3405 Page: 5 of Acceptance Recovery times are a function of airflow velocity, room volume, and the distribution pattern of the HEPA filtered air supply. Acceptable recovery times are to be determined by each facility. The recovery time may be recorded for information only. B. 1. Purpose Results of the particle fallout count indicate the concentration of large airborne particle that are not detected effectively using discrete-particle counters. Particle fallout counts are obtained by allowing a small test surface (witness plate) to collect natural particles (no artificial challenge) that settle out in the cleanroom environment. The particles on the witness plate are counted with a surface particle detection instrument, and a particle deposition rate is determined. 2. Apparatus Witness plate materials should match the type of surface particle detection equipment to be used. Suggested combinations of suitable witness plates and particle detection instruments are: Surface particle detection instrument Microscope, manual or automatic Automatic silicon wafer surface particle detector Suitable witness plate Blank silicon wafers Microscope slides Membrane filters Glass photomask substrates Blank silicon wafers In choosing the method or instrument to be used for this test, consideration should be given to its ability to detect particles in the designated size range appropriate to the specific product being manufactured. The time required
6 ATS-ATP-3405 Page: 6 of 8 for sample analysis and the subjectivity of the procedure should also be considered. Microscopic detection equipment should be set up to detect a minimum particle size of 5 um on the witness plate material selected. The minimum detection limit of silicon-wafer surface-particle detectors is dependent on the model chose, typically in the range of 0.1 to 2 um. A suitable calibration procedure should be established to assure the user that reasonably accurate results are being obtained at each test. 3. Procedure A) Verify that all components of the cleanroom system that contribute to its operation are complete and functioning in accordance with the requirements of the type of cleanroom and the operational mode under test. B) Establish a test point grid at the working level that will satisfy user requirements and be compatible with the type and operational mode of the cleanroom. C) Provide a method of identifying each witness plate. D) Determine and record the background level (before) count on each witness plate, in terms of the average number of particles per square centimeter. average particles = cm 2 total particles on witness plate witness plate area in cm2 E) Provide a sufficient quantity of witness plates to measure the environment and additional witness plates to serves as controls. A minimum of three witness plates should be used as controls. The controls should be handled identically to the other witness plates except that they should not be exposed to the environment.
7 ATS-ATP-3405 Page: 7 of 8 4. Reporting F) Place all witness plates (including the controls) in a suitable, clean container for transportation to the cleanroom test sites. G) Place the witness plate on a surface or support fixture which allows the collection surface to be exposed horizontally at the test point location. Care should be taken to avoid atypical charge potential of the witness plate. Uncover the witness plate immediately before placing it on the support surface. H) Briefly uncover the controls, Place on a support surface, and immediately reinstall the cover and return for particle counting. This count will provide a representation of particles added due to handling. I) Leave the witness plates exposed to the environment for a minimum of 4 hours, or a s long as is necessary to obtain a statistically valid sample, depending on the type of cleanroom, mode of operation, and the test apparatus used. The environmental exposure time should be adequate tot obtain particle samples that satisfy user requirements. J) Take a minimum of three simultaneous particle fallout measurements at each test location. A) Calculate and repot the particle deposition rate as follows: 1) Determine the number of particles per square centimeter added on each of the control witness plates, using the following formula: AC-BC = Paticles/cm2 added to control ACW AC = After Count BC = Before Count
8 ATS-ATP-3405 Page: 8 of 8 5. Acceptance ACW = Area of control witness plate in square centimeters 2) Divide the net particles per square centimeter added by the number of hours the test witness plates wee exposed to the environment. This yields a normalized particle deposition rate in terms of particles per square centimeter per hour. B) Record all individual measurements. Average the readings (three or more) to obtain a mean particle count for each grid location. Record the mean counts on a grid map to show particle fallout levels as a function of location within the cleanroom. Acceptable particle deposition rates should be established by the facility.
Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date
ATS-ATP-3441 Page: 1 of 5 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013
More informationApproval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date
ATS-ATP-3440 Page: 1 of 6 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013
More informationApproval Block. Prepared by: Signature Date. Evan Parnell 17 NOV Reviewed by: Signature Date. Brian Flynn 17 NOV 2014
ATS-SOI-5935 Page: 1 of 5 Approval Block Prepared by: Signature Date Evan Parnell 17 NOV 2014 Reviewed by: Signature Date Brian Flynn 17 NOV 2014 Approved by: Signature Date Kristal Jewell Historical Reference
More informationCleanroom Standards CLEANROOM TUTORIAL PROGRAMME CLEANROOM CLASSES ISO CLEANROOM STANDARDS (SEP 05)
CLEANROOM TUTORIAL PROGRAMME Cleanroom Standards CLEANROOM CLASSES CLASS 1 & 10 These cleanrooms are virtually the exclusive domain of (ISO Class 3 & 4) the microelectronics industry CLASS 100 ntil the
More informationCLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES
CLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES PART I--GENERAL 1.1 Work Included [Edit this specification to eliminate tests not required. Place tests in the desired sequence of performance] A. This
More informationSECTION CLEANROOM CERTIFICATION
SECTION 3 60 9 PART - GENERAL. CONDITIONS AND REQUIREMENTS A. Clean Zone requirements are specified in Sections 0 50 3 and 3 60 3. B. Cleanroom cleaning procedures are specified in Section 3 60 6. C. ing
More informationSpecific Accreditation Criteria
Specific Accreditation Criteria ISO/IEC 17025 Application Document Infrastructure and Asset Integrity - Annex July 2018 Copyright National Association of Testing Authorities, Australia 2013 This publication
More informationCHANGES TO THE STANDARD FOR ISO ISO Cleanrooms and Associated Controlled Environments
CHANGES TO THE STANDARD FOR ISO 14644 1 2015 ISO 14644 2 2015 Cleanrooms and Associated Controlled Environments The newly updated ISO14644-1:2015 has caused some confusion and raised concerns by companies
More informationClean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly!
Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly! Marc Stranz, PharmD, Vice President of Clinical Operations BioScrip, East Greenville, PA Jim Wagner, President
More informationHARBEC Inc Ontario, NY
HARBEC Inc Ontario, NY Cleanroom Certification Report PREPARED FOR 369 Route 104 Ontario, NY 14519-8999 Paul Scheible Engineering Manager Main Cleanroom Gown Room Room Design Classification ISO Class 8
More informationCLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION
Cleanroom Testing and Certification Board Irish Cleanroom Society CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION 10th April 2014 19:30-21:30 Candidates should read the following instructions: Candidates
More informationISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 5: Operations
INTERNATIONAL STANDARD ISO 14644-5 First edition 2004-08-15 Cleanrooms and associated controlled environments Part 5: Operations Salles propres et environnements maîtrisés apparentés Partie 5: Exploitation
More informationAustralian/New Zealand Standard
AS/NZS 14644.3:2009 AS/NZS 14644.3:2009 Australian/New Zealand Standard Cleanrooms and associated controlled environments Part 3: Test methods (ISO 14644-3:2005, MOD) AS/NZS 14644.3:2009 This Joint Australian/New
More informationISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 3: Test methods
INTERNATIONAL STANDARD ISO 14644-3 First edition 2005-12-15 Cleanrooms and associated controlled environments Part 3: Test methods Salles propres et environnements maîtrisés apparentés Partie 3: Méthodes
More informationPARTICLE MEASUREMENT IN CLEAN ROOMS.
ENGLISH PARTICLE MEASUREMENT IN CLEAN ROOMS. PARTICLE MEASUREMENT Particle measurement in clean rooms. WP1508007-0100-EN, V1R0, 2015-08 PARTICLE MEASUREMENT IN CLEAN ROOMS. WHITEPAPER Content Content...
More informationTSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS
TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS APPLICATION NOTE CC-110 (A4) Introduction TSI Incorporated s AeroTrak Remote Particle Counters are used to monitor particulate
More informationFrom Standards to Practice: Sterile Respirator Hoods
From Standards to Practice: Sterile Respirator Hoods Jennifer Galvin, DuPont Safety and Construction Greg Steller, Bullard Philadelphia, PA May 23, 2018 Looking for an answer: Background Regulation Standards
More informationISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 4: Design, construction and start-up
INTERNATIONAL STANDARD ISO 14644-4 First edition 2001-04-01 Cleanrooms and associated controlled environments Part 4: Design, construction and start-up Salles propres et environnements maîtrisés apparentés
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 14644-2 First edition 2000-09-15 Cleanrooms and associated controlled environments Part 2: Specifications for testing and monitoring to prove continued compliance with ISO 14644-1
More informationAgenda. Scope ISO IS : Flowchart. IS : Flowchart. Onderbouwd inschatten en rekenen aan cleanrooms
Agenda Onderbouwd inschatten en rekenen aan cleanrooms Mark Niesen Expert NL WG 4 - ASML 1. Background ISO 14644-4 2. Design process air contamination control Segregation concepts concepts equations Cleanrooms
More informationCLEAN ROOM PROTOCOL AND WAFER HANDLING
CLEAN ROOM PROTOCOL AND WAFER HANDLING Prof. Madya Dr. Uda Hashim 1 Outline Cleanroom Cleanroom protocol Wafer handling procedure 2 CLEANROOM Definition Cleanroom - The cleanliness of the air inside the
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 14644-1 Second edition 2015-12-15 Cleanrooms and associated controlled environments Part 1: Classification of air cleanliness by particle concentration Salles propres et environnements
More informationAirborne Particle Monitoring: Impact of ISO Calibration
Airborne Particle Monitoring: Impact of ISO 21501-4 Calibration Airborne Particle Monitoring: Impact of ISO 21501-4 Calibration Abstract: Dependable, consistent and repeatable results in monitoring airborne
More informationAEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE
AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will
More informationI3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing
I3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing Introduction to Clean Rooms A cleanroom is a controlled environment where Pharmaceuticals, APIs, Medical Devices, Food, Cosmetics,
More informationTest report. Evaluation of particle generation from a chair for use in cleanrooms
Energy Management AB A Chalmers Industriteknik Company Test report Evaluation of particle generation from a chair for use in cleanrooms HÅG Capisco Puls 8010 Ordered by: Scandinavian Business Seating AB
More informationMECHANICAL CONTRACTORS ASSOCIATION OF AMERICA, INC. CLEANROOM PIPING AND PROCEDURES BASIC CONSIDERATIONS
BASIC CONSIDERATIONS For the mechanical contractor, cleanroom construction involves the installation of high purity piping which support an ultra clean environment. This involves extremely stringent requirements
More informationA course entitled. Particle counting to ISO Parts 1& 2
A course entitled Particle counting to ISO 14644 Parts 1& 2 Summary The course is called Particle Counting to ISO 14644: Parts 1 and 2. The course lasts one day. The course is for people who are required
More informationAEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE
AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Model 9306 Handheld Airborne Particle Counter. This guide will help you quickly begin using
More informationBuilding Cleanrooms. - Regulations, Air-Handling, Design & Construction -
Building Cleanrooms - Regulations, Air-Handling, Design & Construction - Created by Michael Starke, Solutions and Handling GmbH, Germany Tel.: +49-2152-553800, Fax: +49-2152-553805, mail: info@solutions-handling.com
More informationMicroContamination Solutions, Inc. P.O. Box 6897, Incline Village, Nevada 89450
To: Jeff Winters, Michael Freier From: Edward Vitenberg Subject: MultiMetrixs End-Effector Cleanliness Test Report Date: October 4, 2002 I. Overview MultiMetrixs End-Effector Cleanliness Test Report For
More informationThe modular application of the cleanroom solutions for manufacturing facilities
White Paper The modular application of the cleanroom solutions for manufacturing facilities Cleanroom facilities in the U.S. have grown fourfold since 1998, reaching an estimated 180 million square feet.
More informationApplication of IBM s s Corporate Ventilation Process at a Semiconductor Facility
Application of IBM s s Corporate Ventilation Process at a Semiconductor Facility AIHA International Ventilation Conference 2005 Robert Desrosiers - IBM 1 IBM - Burlington Overview Site mission Technology
More informationA smart system with an easy touch APC SmartTouch. Airborne Particle Counter
A smart system with an easy touch APC SmartTouch Airborne Particle Counter APC SmartTouch Setting new standards Particle counting is a critical component of cleanroom monitoring programs. Detecting contaminants
More informationCLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION
Cleanroom Testing and Certification Board Irish Cleanroom Society CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION 1 April 2009 1730-1930 Candidates should read the following instructions: 1) Candidates
More informationFS209E and ISO Cleanroom Standards
FS209E and ISO Cleanroom Standards Before global cleanroom classifications and standards were adopted by the International Standards Organization (ISO), the U.S. General Service Administration s standards
More informationISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 4: Design, construction and start-up
INTERNATIONAL STANDARD ISO 14644-4 First edition 2001-04-01 Cleanrooms and associated controlled environments Part 4: Design, construction and start-up Salles propres et environnements maîtrisés apparentés
More informationCleanroom Certification Report
2880 Bergey Road, Ste. K Hatfield, PA 19440 www.envservices.com 800-345 - 6094 Presents: Cleanroom Certification Report Control ID #: 315-165018-7598 Prepared for: SICBOY INDUSTRIES 1218 COMMERCE CT, UNIT
More informationPolicy for Accrediting Assessment Bodies Operating within the Cradle to Cradle Certified Product Certification Scheme. Version 1.2
Policy for Accrediting Assessment Bodies Operating within the Cradle to Cradle Certified Product Certification Scheme Version 1.2 July 2015 Copyright, Cradle to Cradle Products Innovation Institute, 2015
More informationHOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT
HOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT By Kevin Weist, president Clean Air Products A well-designed, aesthetically pleasing modular hardwall cleanroom
More informationCLEAN ROOM TECHNOLOGY
CLEAN ROOM TECHNOLOGY Justin Mathew Applied Electronics and Instrumentation College Of Engineering, Trivandrum April 28, 2015 Justin Mathew (CET) Clean Room Technology April 28, 2015 1 / 18 Overview 1
More informationA copy can be downloaded for personal non-commercial research or study, without prior permission or charge
Whyte, W., Ward, S., Whyte, W.M., and Eaton, T. (2014) Decay of airborne contamination and ventilation effectiveness of cleanrooms. International Journal of Ventilation, 13 (3). pp. 1-10. Copyright 2014
More informationPOST-INTEGRATION CHECKOUT OF SUSPENSION CABLES
STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 POST-INTEGRATION CHECKOUT OF SUSPENSION CABLES -B SCIENCE
More informationAPRIL 2010 VOL. 13 NO. 4. Modular Cleanrooms for Business Startups and New Product Development
APRIL 2010 VOL. 13 NO. 4 Modular Cleanrooms for Business Startups and New Product Development Modular Cleanrooms for Business Startups and New Product Development www.cemag.us Modular Cleanrooms for Business
More informationProgram ROAD Manager MAP Certification
Program Certification Manager The Route to ESD Control Roadmap The purpose of the Roadmap is to project the impact of technology scaling in the semiconductor industry. To develop the Roadmap, ESD devices
More informationIOM Personal Sampler
Operating Instructions 863 Valley View Road, Eighty Four PA 15330 USA Tel: 724-941-9701 Fax: 724-941-1369 e-mail: skctech@skcinc.com IOM Personal Sampler Description The patented* IOM Sampler is a sampling
More informationWHITEPAPER CLEAN ROOM DESIGN AND THE ROLE OF FLOORING. An overview of cleanroom design and flooring considerations to ensure regulatory compliance.
CLEAN ROOM DESIGN AND THE ROLE OF FLOORING An overview of cleanroom design and flooring considerations to ensure regulatory compliance. Contact the Flooring Specialist +61 7 3205 7115 (Brisbane) +61 2
More information-SQA- SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION
-SQA- SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION -Unit Number- 3450764 -Superclass- -Title- PL SAFETY AND CLEANROOM PRACTICE -------------------------------
More informationObtaining the Weld Quality You Need. What to Look for in a Cleanroom Welding Contractor
Obtaining the Weld Quality You Need What to Look for in a Cleanroom Welding Contractor What is Cleanroom Welding? Welding within a cleanroom ensures that there is a low level of contaminants such as dust,
More informationKarl Suss SB6 Bonder Operation Tool Id: Rev 01, 09/24/10
Karl Suss SB6 Bonder Operation Tool Id: 119.020 The technical content of this document is the responsibility of UCLA CNSI Integrated Systems Nanofabrication Cleanroom Los Angeles, CA Karl Suss SB6 Bonder
More informationCleanrooms and Standards The Road Ahead
Cleanrooms and Standards The Road Ahead Andrew Watson CBE AIRAH Kirribilli Club 30 th October 2017 About me My career over 20 years covering: Production Design Construction Consulting Standards preparation
More informationPREPARE PROBE FOR CLASS 10 CLEANROOM
SU/GP-B P0409 Rev STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 PREPARE PROBE FOR CLASS 10 CLEANROOM GP-B
More informationthe closed-loop control system
the closed-loop control system A definitive change in cleanroom technology The Connect 2 Cleanrooms closed-loop control system is designed to ensure the cleanroom operates at optimum effectiveness whilst
More informationEnergy Saving in Cleanrooms
Energy Saving in Cleanrooms Energy Saving in Cleanrooms Dr. Alexander Fedotov, Director of Invar-project Company, Moscow, Russia fedotov@invar-project.ru www.invar-project.ru Presentation discusses : Methods
More informationFS209E and ISO Cleanroom Standards
FS209E and ISO Before global cleanroom classifications and standards were adopted by the International Standards Organization (ISO), the U.S. General Service Administration s standards (known as FS209E)
More informationPARTICLE GENERATION FROM HUMANS A METHOD FOR EXPERIMENTAL STUDIES IN CLEANROOM TECHNOLOGY
Proceedings: Indoor ir 25 PRTICLE GENERTION FROM HUMNS METHOD FOR EXPERIMENTL STUDIES IN CLENROOM TECHNOLOGY M Ramstorp *, M Gustavsson and Gudmundsson Division of Ergonomics and aerosol technology, Department
More informationMontgomery County Community College Document Number: DP DeKalb Pike Revision Number: 2. Page 1 of 9 SOP: BioLogic LP Chromatography System
Page 1 of 9 Approvals Preparer: Jason McMillan Reviewer: Dr. Maggie Bryans Date: 18DEC14 Date: 18DEC14 1. Purpose: Operation of the BioLogic LP Chromatography System. 2. Scope: Applies to the BioLogic
More informationUNDERSTANDING DIFFERRENT ASPECTS OF PROTECTIVE GARMENT SOLUTIONS
UNDERSTANDING DIFFERRENT ASPECTS OF PROTECTIVE GARMENT SOLUTIONS IN CLEANROOMS & CONTROLLED ENVIRONMENTS Nancy Baeten DuPont Protection Solutions BCW College Day - September 2017 MARKETS AND APPLICATIONS
More informationTitle: Standard Operating Procedure for Measurement of Particulate Matter in Ambient Air by Orthogonal Light Scattering
Procedure No: SOP-014 Revision No: 0 (new document) Page No.: 1 of 10 1. INTRODUCTION AND SCOPE The Grimm particulate monitor is used by Alberta Environment (AENV) in the Mobile Air Monitoring Laboratory
More informationRestricted Access Barrier Systems (RABS) & Isolators: The Perfect Combination of Robot System Safety and Aseptic Drug Manufacturing
MACHINE DESIGN AND MANUFACTURING Automated Systems of Tacoma 4110 South Washington St. Tacoma, WA 98409 (253) 475-0200 www.ast-inc.com Restricted Access Barrier Systems (RABS) & Isolators: The Perfect
More informationA copy can be downloaded for personal non-commercial research or study, without prior permission or charge
Whyte, W., Ward, S., Whyte, W.M., and Eaton, T. (2014) The application of the ventilation equations to cleanrooms - Part 2: Decay of contamination. Clean Air and Containment Review (20). pp. 4-9. Copyright
More informationTitle: Karl Suss MA150 Semiconductor & Microsystems Fabrication Laboratory Revision: E Rev Date: 03/01/06
Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Karl Suss MA150 Mask Aligner. All users are expected to have read and understood
More informationEOQ methods and criteria for approval of training courses and training providers
1. Scope This document is describing EOQ rules and criteria to be used for the approval of training providers and training courses using as reference the EOQ Competence Specifications (CoS) and by Accreditation
More informationCONNECT INPUT CABLE TO SQUID P0682 Rev -
1 STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 SU/GPB P0682 Rev - CONNECT INPUT CABLE TO SQUID P0682
More informationHoworth Air Technology. Pharmaceutical Aseptic Isolators and Barriers
Howorth Air Technology Pharmaceutical Aseptic Isolators and Barriers Aseptic Processing For more than 150 years, the Howorth name has represented technical creativity and expertise in air engineering and
More informationOperational Safety Procedure (OSP) For The. Laser Bay. At the. Texas Center for High Intensity Laser Science. Document Number TPW-D-0011-A
Operational Safety Procedure (OSP) For The Laser Bay At the Texas Center for High Intensity Laser Science Document Number TPW-D-0011-A Texas Center for High Intensity Laser Science Dept. of Physics, The
More information10 COMMON TRAPS IN DESIGNING A CLEANROOM
10 COMMON TRAPS IN DESIGNING A CLEANROOM Executive summary Cleanrooms provide a controlled environment with a low level of pollutants. They are typically used for manufacturing or scientific research activities
More informationAir Technology Division
Air Technology Division AIR HANDLING UNITS FS 209E A IR V E NTI L ATI O N S Y E ST M Registered Office : Fullorhat, Ahutibagan, Near Fullorhat Yuba Sangha, Sonarpur, Kolkata - 700 150, W.B., India Cell
More informationMODELING PARTICLE DEPOSITION IN VENTILATION DUCTS
MODELING PARTICLE DEPOSITION IN VENTILATION DUCTS MR Sippola 1* and WW Nazaroff 1,2 1 Dept. of Civil and Environmental Engineering, University of California, Berkeley, CA, USA 2 Indoor Environment Dept.,
More informationWhat is a cleanroom? CMi cleanroom concept. CMi User Manual. Working in CMi cleanroom. Safety at CMi. Visit of the cleanroom
1 What is a cleanroom? CMi cleanroom concept CMi User Manual Working in CMi cleanroom Safety at CMi Visit of the cleanroom 2 3 What is a cleanroom? Continuous air supply through filters. Laminar flow top
More informationIntroduction to Contamination Cotitrol and Cleanroom Technology Matts Rarnstorp copyright 0 WXLEY-VCI.? Verlag GmbH, 2000
Introduction to Contamination Cotitrol and Cleanroom Technology Matts Rarnstorp copyright 0 WXLEY-VCI.? Verlag GmbH, 2000 Further reading (1993). HEPA and ULPA Filter, IEST-RP-CC-001.3. ISBN 1-877862-40-1.
More informationCleanrooms and associated controlled environments. Part 14: Assessment of suitability for use of equipment by airborne particle concentration
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 14644-14 First edition 2016-09-15 Cleanrooms and associated controlled environments Part 14: Assessment of suitability for use of equipment by
More informationMOUNT PROBE ONTO PRECISION MANIPULATOR
SU/GP-B STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 MOUNT PROBE ONTO PRECISION MANIPULATOR GP-B SCIENCE
More informationReliable Environmental Monitoring Systems by Design
Reliable Environmental Monitoring Systems by Design Written by Simon Tebb, TSI - Contamination Control Sales Manager Europe, Middle East & Africa Environmental Monitoring Systems (EMS) In Cleanrooms, data
More informationOctober 21-23, 2013 Holly Springs, NC
NEBB s Cleanroom Performance Testing Certified Professional Seminar and Exam October 21-23, 2013 Holly Springs, NC Introduction: NEBB, in continuance of its policy to enhance education and training within
More informationSOLAIR Portable. Airborne Particle Counters 2017/11/09
SOLAIR Portable Airborne Particle Counters 2017/11/09 SOLAIRPortable 1100LD 1.0 CFM - Airborne Particle Counter The Lighthouse SOLAIR 1100LD (Laser Diode) leads the industry as the first of it s kind portable
More informationA Basic Introduction to Clean Rooms
A Basic Introduction to Clean Rooms By Roger McFadden Senior Scientist, Staples Inc. A cleanroom is a controlled environment where products are manufactured. It is a room in which the concentration of
More informationDeposition velocities of airborne microbecarrying
European Journal of Parenteral & Pharmaceutical Sciences 2016; 21(2): 45-49 2016 Pharmaceutical and Healthcare Sciences Society Deposition velocities of airborne microbecarrying particles W Whyte 1 and
More informationTRANSFER THE QB/T FROM THE OPTICAL TABLE TO VERTICAL MANIPULATOR
SU/GP-B P0404 Rev STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 TRANSFER THE QB/T FROM THE OPTICAL TABLE
More informationTechnovation Systems, Inc
Technovation Systems, Inc A Cleanroom Design/Build & Contamination Control Company 804-744 744-0604 tjm@technovation.org 02/03/06 1 Technovation Systems, Inc. Products & Services Design/Build services:
More informationTEA, Inc. CORPORATE HEALTH AND SAFETY PROGRAM
CORPORATE HEALTH AND SAFETY PROGRAM Updated June 24, 2013 August 12, 2013 Prepared by 10636 Linkwood Court Baton Rouge, Louisiana 70810 Phone: (225) 767-3880 Fax: (225) 767-3883 TABLE OF CONTENTS Section
More informationCleanroom Performance
Cleanroom Performance Testing (CPT) Seminar March 4-6, 2019 Vancouver, WA Location: This Seminar is Designed for: This seminar is intended for individuals with a minimum of two years of cleanroom testing
More informationSSPP-TEV-035 HITCHHIKER ADVANCED CARRIER EQUIPMENT RANDOM VIBRATION TEST PLAN BASIC RELEASE MARCH 1997 GODDARD SPACE FLIGHT CENTER GREENBELT, MARYLAND
HITCHHIKER ADVANCED CARRIER EQUIPMENT RANDOM VIBRATION TEST PLAN SSPP-TEV-035 BASIC RELEASE MARCH 1997 GODDARD SPACE FLIGHT CENTER GREENBELT, MARYLAND PREPARED BY: 5050 POWDER MILL ROAD BELTSVILLE, MD
More informationISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 5: Operations
INTERNATIONAL STANDARD ISO 14644-5 First edition 2004-08-15 Cleanrooms and associated controlled environments Part 5: Operations Salles propres et environnements maîtrisés apparentés Partie 5: Exploitation
More informationthe closed-loop control system
the closed-loop control system A definitive change in cleanroom technology The Connect 2 Cleanrooms closed-loop control system is designed to ensure the cleanroom operates at optimum effectiveness whilst
More informationBHG Operational Awareness Program May 8, 1998 Surveillance Guide NSS-18.1 Revision 0 Criticality Safety Page 1 of 8 CRITICALITY SAFETY
Criticality Safety Page 1 of 8 1.0 Objective The objective of this surveillance is to ensure that effective programs have been developed and implemented to protect the public and DOE's workers from unplanned
More informationFluke 983. Users Manual. Particle Counter. 99 Washington Street Melrose, MA Phone Toll Free
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Fluke 983 Particle Counter Users Manual PN 2414721 January 2005 2005 Fluke Corporation.
More informationCleanroom Performance
Cleanroom Performance Testing (CPT) Seminar October 7-9, 2019 Gaithersburg, MD Location: This Seminar is Designed for: This seminar is intended for individuals with a minimum of two years of cleanroom
More informationUnderstanding Particle Counter Technology and the risks of data integrity of particle counts. by Jason Kelly
T E C H N I C A L P A P E R Understanding Particle Counter Technology and the risks of data integrity of particle counts. by Jason Kelly 06/11/2018 Understanding Particle Counter Technology and the risks
More informationDustTrak Presentation
DustTrak Presentation Agenda + Introduction why do we need to sample? + Dusttrak market segments and applications + Product Line Models Features Theory of Operation Specifications + Accessories + Questions
More informationThis is the author s final accepted version.
Whyte, W., Hejab, M., Whyte, W.M. and Green, G. (2010) Experimental and CFD airflow studies of a cleanroom with special respect to air supply inlets. International Journal of Ventilation, 9(3), pp. 197-209.
More informationHandheld Laser Particle Counter. Model: P311. Operation Manual. Ver: 1.50 AIRY TECHNOLOGY INC
Handheld Laser Particle Counter Model: P311 Operation Manual Ver: 1.5 AIRY TECHNOLOGY INC 1 Warranty AIRY TECHNOLOGY INC warrants to the original user that this instrument shall be free from defects in
More informationUSER MANUAL Video Particle Counter with built in Camera Model VPC300
USER MANUAL Video Particle Counter with built in Camera Model VPC300 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model VPC300
More informationCleanroom Suitability Assessment of Equipment according to upcoming ISO standards. Frank Buerger, Fraunhofer IPA, October 10 th 2013, Dresden
Cleanroom Suitability Assessment of Equipment according to upcoming ISO standards Frank Buerger, Fraunhofer IPA, October 10 th 2013, Dresden Solar Flat Panel Semiconductor Technology and Cleanliness Trends
More informationISPE Thailand 3 rd Seminar 2018
ISPE Thailand 3 rd Seminar 2018 Contamination Risk Assessment in Pharmaceutical Cleanrooms & How to use Airflow Visualization (Smoke Studies) to troubleshoot Cleanroom Contamination issues 29 th 30 th
More informationISO CLEANROOM STANDARDS FEDERAL CLEAN ROOM CLASSIFICATIONS
page 1 / 5 page 2 / 5 iso cleanroom standards federal pdf FS209E and ISO Cleanroom Standards. Terra Universal is the leading expert in the design and fabrication of criticalenvironment applications. We
More informationModel VDL 115 Vacuum drying chambers for flammable solvents
Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber
More informationReliable Protection with RABS. Restricted Access Barrier System Reliable Protection of Product and Process. Together always one step ahead
Reliable Protection with RABS Restricted Access Barrier System Reliable Protection of Product and Process Together always one step ahead Reliable Protection of Product and Process with RABS SKAN SKAN,
More informationمعتبرسازي. Validating, establishing and maintaning a routine environmental monitoring program for clean rooms
استقرار و حفظ يك برنامه معتبرسازي محيطي در اتاق هاي جاري مانيتورينگ تميز Validating, establishing and maintaning a routine environmental monitoring program for clean rooms ١ THE SAME IMPORTANCE!!!!! Cleanroom
More informationASSE PROFESSIONAL CERTIFICATION PROGRAMS PROCTOR GUIDE
ASSE International ASSE PROFESSIONAL CERTIFICATION PROGRAMS PROCTOR GUIDE This guide was established to provide uniformity and requirements for proctoring ASSE Certification program exams. An ASSE accredited
More information