MTeC - EPT202 Digital thermometer Messko
|
|
- Oscar Wilkerson
- 5 years ago
- Views:
Transcription
1 MTeC - EPT202 Digital thermometer Messko
2 MTeC -EPT202 the all-roundermto ST160 und MTO STF 160 The main functions such as Power, Alarm, Trip, Error and the operating status of the individual fan groups are quickly identifiable by means of the LEDs in the control panel. An examination of the ageing behaviour of the insulation system of transformers and therefore the service life in particular shows that these are largely dependent on the temperature in the winding. This temperature is primarily determined by the load of the transformer, the parameterization of the cooling control and the overall design of the cooling equipment. The activation and deactivation of the radiator, controlled by the temperature of the oil or winding, are particularly important in this respect. A temperature monitoring system and fan control customized to the individual conditions posed by the respective transformer equipment firstly increases the expected service life of the transformer and secondly reduces the total losses through fan running times optimized for the load and temperature. The radiators are controlled individually according to the type of cooling. The new MTeC -EPT202 equipment generation (digital thermometer with loaddependent fan control) combines a number of functions for monitoring the temperature of transformers. The clear central display shows all of the equipment information for operating and programming the MTeC, according to the menu item. The basic device displays and monitors the temperature of the oil and winding. The maximum and minimum values for the temperatures and load current are recorded and can be called up later. Two analogue outputs and a RS485 interface are available for remote indication of the temperature values.
3 Navigation through the individual menu is child's play thanks to the cursor keys on the right-hand side next to the central display. You can intuitively navigate your way through the individual function areas. The input can be freely parameterised depending on which sensor you use to measure the oil temperature (4 ma ma or Pt100). We use safety screw terminals for communication and connecting the supply lines, control wires and sensor lines. In addition, these terminals simplify the assembly of the device in its place of installation. You can configure the individual main switching contacts so that they are assigned to either the oil temperature or winding temperature. It is also possible to switch each fan group manually.
4 In the "peak-value" menu item, you will find handy variants of "mechanical drag hands". Minimum/maximum values for the oil and winding temperatures and the maximum load current are recorded and displayed. The input can be freely parameterised depending on which sensor you use to measure the oil temperature (4 ma ma or Pt100). The main switching contacts can be checked extremely easily as part of the regular checks, using the Test function. All equipment functions continue to run in the background. You can configure the individual main switching contacts so that they are assigned to either the oil temperature or winding temperature. It is also possible to switch each fan group manually.
5 MTeC -EPT202 The functions at a glance The lifetime of your transformer substantial depends on the thermal aging of the winding. The MTeC calculates the service life already elapsed according to international standards. The new MTeC -EPT202 equipment generation (digital thermometer with loaddependent fan control) combines a number of functions for monitoring the temperature of transformers: + Measurement/display of the temperature of the oil and 1 to 3 windings + Oil level display for on-load tap-changer and transformer oil conservator + Intelligent (cooling type- and load-dependent) fan control + Calculation of residual service life in line with international standards + Storage of data + Remote monitoring and parameterization via a SCADA system or on site via PC + Reduction of power loss (fan) and noise emissions + Targeted monitoring and reduction of thermal load of transformer MTeC -EPT202 Modular structure Top oil temperature CT phase 1 Parameter Oil level CTphases 2 and 3 PT ma The outputs of the MTeC can be set as required. If you wish to connect another device at a later date, simply redefine the parameters of the output. EPT 202 OL/CT OL CT Analog Oil temperature, winding temperature SCADA Digital Analog Extensionmodules Oil level
6 MTeC Technical Data of EPT202 Protective housing Rail mounting: Aluminium housing, snaps on to mounting rail in line with DIN EN TH and TH 35-15, degree of protection IP 00 in line with IEC 60529, weight approx. 1.2 kg 19 sub-rack: 19 plug-in housing in line with DIN part 5, 223 x 133 x 178 mm (W x H x D) for mounting in 19 cabinet system, degree of protection IP 00 in line with IEC 60529, weight approx. 1.5 kg Flush panel mounting: Aluminium housing 270 x 200 x 133 mm (W x H x D) for panel cut-out 236 mm x 142 mm (W x H), degree of protection IP 00 in line with IEC 60529, weight approx. 1.5 kg Installation in ED from MR: 19 plug-in housing in line with DIN part 5, 483 x 133 x 178 mm (W x H x D), degree of protection IP 00 in line with IEC 60529, weight approx. 2.5 kg Operation: Storage: Control elements: Display: Status LEDs: Supply voltage: Temperature sensor: Current transformer input: Temperature range -25 C +70 C -30 C +85 C Control elements, displays 5 x function keys with tangible pressure point Monochrome display, White characters on blue illuminated background, 128 x 64 dot 1 x green LED for Power operating display 1 x yellow LED for Alarm contact 1 x red LED for TRIP contact 1 x red LED for ERROR contact 4 x yellow LEDs for S1, S2, S3 and S4 contacts Inputs 100 V AC 240 V AC, 50 Hz 400 Hz or 100 V DC 353 V DC, power consumption: max. 10 VA or W Pt100-Signal in line with IEC 751 in 2- or 3-conductor technology or 4 20 ma signal (active or passive), standard measuring range: -20 C +140 C (others available on request) Instrument transformers can be provided for other input signals such as 0 1 ma or 0 10 V. 0,5 5 A rated CT current, durability: 10 A for 8 hours, short-time current: 500 A for 1 second Outputs Analog outputs: 1 x oil temperature (Oil Temp.), temperature range: -20 C +140 C, 1 x winding temperature (Winding), temperature range: 0 C 160 C Both analog outputs can be set as required within the following ranges: 0 10 V 0 1 ma 4 20 ma (errorsignal < 3,6 ma) 4 20 ma (errorsignal > 22 ma) 0 20 ma (errorsignal > 22 ma) Interfaces: 1 x RS 232 on 9-pole D-Sub connector for parametrization and data logging via PC 1 x RS 485 on screw terminals 1 x SPI-Bus on 15-pole D-Sub connector for connecting additional modules Relais 4 x SPDT contacts for switching points S1 S4, make/break capability of contacts, AC: 250 V/12A, DC: 110 V/0.4 A 2 x SPDT contacts for ALARM and TRIP, make/break capability of contacts, AC: 250 V/5A, DC: 110 V/0.4 A 1 n/c contact for Error message, make/break capability of contact, AC: 250 V/5A, DC: 110 V/0.4 A Tests Elektrical safety: Class 1 protection as per IEC Pollution degree 2 as defined in IEC report Overvoltage category III as defined in IEC report ECE conformity: EMC Directive 89/336 EEC Low Voltage Directive 72/23 EEC
7 MTeC -EPT202 the all-rounder MTO ST160 und MTO STF 160 Transformer (optional) CT phase1 CT phase 2 CT phase 3 Oil temperature Oil level tank (optional) Oil level OLTCILTC Sensor MT-ST160SK-TT Pt100 Cooling control MTO- STF160TT + + TT-PWM60 Combi well Analog input Analog input Control cabinet RS485 RS232 Digital output Analog output oil temperature, winding temperature Signal contacts alarm, error, trip Analog output oil levels Control room C D1272 PQ 96 EI100 Signalling lamp D1272 EI100 operations center SCADA system
8 Messko GmbH 2005 Gablonzer Strasse Oberursel, Germany Phone +49 (0) Fax +49 (0) Please note: Certain aspects of the equipment delivered may differ from the information given in any of our publications. Subject to changes. IN 2075/01en 0105/ /01/2000 Art. no Printed in Germany Messko/Usa Messko
Trafoguard reliable monitoring of Transformer operating statuses. Transformer control
Trafoguard reliable monitoring of Transformer operating statuses. Transformer control 2 Trafoguard Trafoguard money can't buy a better way of ensuring economic Transformer operation. Trafoguard Trafoguard
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description
(-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase
More informationOP10. Pre-programmed, configurable controller for simple applications
revision 10 2013 OP10 Pre-programmed, configurable controller for simple applications The Optigo OP10 range of controllers can be set to handle everything from temperature or humidity control to control
More informationTAPCON 240 Voltage Regulator for Regulating Transformers
www.reinhausen.com TAPCON 240 Voltage Regulator for Regulating Transformers TAPCON The next generation of voltage regulators TAPCON : a name which is synonymous for an entirely new and ground-breaking
More informationSafety Temperature Limiter TT-STL 50
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature
More informationDual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx
D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationElectronic timer CT-ERD.12
2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationProduct and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING
Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.
More informationElectronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet
2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time
More informationRM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC
Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationElectronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet
Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine
More informationTAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS.
TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS. WWW.REINHAUSEN.COM TAPCON 250 TAPCON 250 THE NEW GENERATION OF VOLTAGE CONTROLLERS. For more than 40 years voltage
More informationtapcon 230 user-friendly, FleXiBle and reliable. transformer control
tapcon 230 user-friendly, FleXiBle and reliable. transformer control Tapcon 230 tapcon 230 the new standard in voltage control. 2 Maschinenfabrik Reinhausen (MR) has been developing and manufacturing voltage
More informationSwitching relay CT-IRE with 1 c/o (SPDT) contact
Data sheet Switching relay CT-IRE with 1 c/o (SPDT) contact The CT-IRE is a switching relay from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance
More informationRM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC
Characteristics phase control relay RM17-T - range 183..484 V AC Complementary Maximum switching voltage Minimum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage
More informationRM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary
Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet
2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication
More informationElectronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact The CT-ARE is an electronic time relay with OFF-delay. It is from the CT-E range. The CT-E range is the economic
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationRM35TF V AC
Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters
More informationProduct and functional description
Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationElectronic timer CT-ERS.21
2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationNetworks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks
Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus
More informationElectronic timer CT-AHD.22
2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationAlarm Unit DG 3200 Control And Monitor Standard Signals
Alarm Unit DG 3200 Control And Monitor Standard Signals With the Alarm Unit DG 3200 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique. The Alarm Unit
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationEY-EM : Remote I/O module, ecolink
EY-EM 510...512: Remote I/O module, ecolink510...512 How energy efficiency is improved Optimum adjustment to applications by means of module technology. Reduction in wiring Features Part of the SAUTER
More informationABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011
Technical data 2CDC508136D0202 ABB i-bus KNX Product description The device is a modular installation device (MDRC) in Pro M design. It is intended for installation in distribution boards on 35 mm mounting
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationElectronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationMPreC - Pressure Relief Device Order specification sheet
- Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationRM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA
Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching
More informationISOMETER isopv with coupling device AGH-PV
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling
More informationOnline data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS
Online data sheet TBS-1BSGT3506FM TBS A B C D E F Illustration may differ Detailed technical data Features Ordering information Type Part no. TBS-1BSGT3506FM 6053202 Other models and accessories www.sick.com/tbs
More informationTAPCON 230 Voltage Regulator for Regulating Transformers
www.reinhausen.com TAPCON 230 Voltage Regulator for Regulating Transformers TAPCON Voltage regulators of the next generation TAPCON : a name which stands for a completely new range of voltage regulators
More informationABB i-bus KNX HCC/S Heating/cooling circuit controller
ABB i-bus KNX HCC/S 2.2.1.1 Heating/cooling circuit controller Description of product The device is a modular DIN rail component (MDRC) in pro M design. It is intended for installation in distribution
More informationIRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)
IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationRCMB20/RCMB Series
4 T M /-500 Series Integratable Ground Fault Monitoring Modules For Integration Into Frequency Converters and Combiner Boxes Technical Bulletin NAE1042510 / 10.2012 BENDER Inc. 700 Fox Chase, Coatesville
More informationMCX08M2 Programmable controller
Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection
More informationTM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus
Product data sheet Characteristics TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus Product availability : Stock - Normally stocked in distribution facility Price* : 427.58 USD Main
More informationDALI Professional Controller-4. Control unit Operating instructions
LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections
More informationAC-DC Converter REC K10
Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,
More informationABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011
Technical Data 2CDC505168D0201 ABB i-bus KNX Product description The Analogue Actuator converts telegrams received via KNX into analog output signals. The device has four outputs. The analog outputs can
More informationVISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:
Technical Documentation VISY-Output 8 8-Channel relay output module Version: 3 Edition: 2016-09 Art. no.: 350072 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07 0 Fax:
More informationUMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.
RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels 20 Channel Branch Circuit Monitoring Device with RCM Interfaces / communication RS485 RTU Accuracy of measurement
More informationABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011
, 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for
More informationRM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.
Characteristics voltage control relay RM17-U - range 9..15 V DC Price* : 70.64 GBP Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters
More informationTechnical Datasheet clima RCM-CC
Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationPower Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5
Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of
More informationABB i-bus KNX Fan Coil Actuators FCA/S Product Manual
Fan Coil Actuators FCA/S Product Manual Contents 1 General... 5 1.1 Using the product manual...5 1.1.1 Notes...6 1.2 Product and functional overview...7 1.2.1 Product overview...7 1.2.2 Functional overview...8
More informationTemperature controller Ducted systems
2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More informationLine Coupler, MDRC LK/S 3.1, GH Q R0001
, GH Q605 0067 000 The coupler can be used as a line The coupler is installed in the distribution board on the data rail of the coupler or a backbone coupler. CDC 07 0 F000 As a line coupler, it links
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationAIAS. Technical description
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationElectronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet
2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationSafety controller unit B1 /
Version 1.0 Safety controller unit 470111B1 / For 2 to 16 safety sensors 470115B1 PL d in acc. with EN ISO 13849-1 / SIL CL 2 in acc. with EN IEC 62061 Two safety outputs and external contactor monitoring
More informationOEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers
OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting
More informationUMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM
20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationLinear Position Transducer HLT 1000-R2
7 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and
More informationUniversal Controller
3 342 Universal Controller For comfort control in HVAC & R-Systems Standalone electronic universal controller with P or PI response Operating voltage in accordance to type AC 24 V Control application selectable
More informationElectronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and
More informationRM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O
Product datasheet Characteristics RM22LA32MR Level control relay RM22-L - 24..240 V AC/DC - 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay
More informationLeutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14
Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland
More informationSafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay
EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-PS1) 1 2 3 4 5 7 6 Component Identification 1 Supply module 1794-PS1 2 Indicator 3 120/230V ac ground 4 120/230V ac common L2/N connections 5 120/230V ac power
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationEMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.
Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More informationRM35LM33MW liquid level control relay RM35-L V AC/DC
Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Complementary reset time maximum switching voltage Main range of product product or component type relay type relay name relay monitored
More informationProduct and functional description
Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationProcess controllers for the meat processing industry
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationRoom Temperature Controllers
3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationRM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases
Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching
More informationABB i-bus KNX Fan Coil Actuators FCA/S Product Manual
Fan Coil Actuators FCA/S Product Manual Contents 1 General... 5 1.1 Using the product manual...5 1.1.1 Notes...6 1.2 Product and functional overview...7 1.2.1 Product overview...7 1.2.2 Functional overview...8
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationJ itron DR 100 Microprocessor Controller
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 60030 Fax: +49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net
More informationRM35LM33MW liquid level control relay RM35-L V AC/DC
Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Complementary Reset time Maximum switching voltage [Un] rated nominal voltage Supply voltage limits Operating voltage tolerance Power
More informationEMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks
Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008
More information