Keysight N5990A Type-C Extension. User Guide

Size: px
Start display at page:

Download "Keysight N5990A Type-C Extension. User Guide"

Transcription

1 Keysight N5990A Type-C Extension User Guide

2 Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws. Manual Part Number N Manual Edition December, 2017 Keysight Technologies Deutschland GmbH Herrenberger Strasse 130, Böblingen, Germany Technology Licenses The hard ware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. U.S. Government Rights The Software is commercial computer software, as defined by Federal Acquisition Regulation ( FAR ) Pursuant to FAR and and Department of Defense FAR Supplement ( DFARS ) , the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR and and DFARS , the U.S. government acquires no greater than Limited Rights as defined in FAR or DFAR (c), as applicable in any technical data. Warranty THE MATERIAL CONTAINED IN THIS DOCU- MENT IS PROVIDED "AS IS," AND IS SUB- JECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDEN- TAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCU- MENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREE- MENT WITH WARRANTY TERMS COVER- ING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. 2 Keysight N5990A Type-C Extension User Guide

3 Contents 1 Introduction Overview 6 2 ValiFrame Station Configuration 2 USB 8 3 ValiFrame DUT Configuration DisplayPort 9 Thunderbol t 10 Remote Instruments Server 10 Instrument Configuration 11 USB 14 DisplayPort 18 Thunderbol t 20 PDO Configuration 21 Keysight N5990A Type-C Extension User Guide 3

4 Contents 4 Connection Diagrams 4 4 USB 26 Rx Tests with M8020A 26 LFPS Rx Tests with M8020A 28 Rx Tests with N4903B 29 DisplayPort 31 Rx Tests with M8020A 31 Rx Tests with N4903B 33 Rx Tests with ParBERT 7G 34 Rx Tests for DP 2+2 mode 35 Thunderbol t 37 Rx TP2 Tests with M8020A 37 Rx TPEQ Tests with M8020A 39 5 Calibration Procedures References 42 6 Rx Test Procedures PDO Iterations Node 44 7 Contact Information 4 Keysight N5990A Type-C Extension User Guide

5 Keysight N5990A Type-C Extension User Guide 1 Introduction Overview / 6

6 1 Introduction Overview The Keysight Technologies N5990A Test Automation Software Platform ValiFrame is an open and flexible framework for automating tests of the latest digital bus standards. This QuickStart guide describes how to configure the Type-C PDO test options in the ValiFrame Rx tests for USB3.1, DisplayPort and Thunderbolt. The use of the PDOs (Power Data Object) allows the inclusion of different power contracts in the test plan. NOTE This document is just a short overview over the PDO test extension.it is not a complete manual for using those applications. For each particular standard, please refer to the following documents: Keysight N5990A Test Automation Software Platform for USB Keysight N5990A-155 Test Automation Software Platform for Display Port Keysight N5990A-104 Test Automation Software Platform for Thunderbolt The PDO test extension requires the option Type-C enabling. It is a supplement to the standard ValiFrame-USB, ValiFrame-Thunderbolt or ValiFrame-DisplayPort-Module. It only works in conjunction with a basic license for these standards. 6 Keysight N5990A Type-C Extension User Guide

7 Keysight N5990A Type-C Extension User Guide 2 ValiFrame Station Configuration USB / 8 DisplayPort / 9 Thunderbolt / 10 Start the Station Configuration of the particular ValiFrame application to choose and connect to the relevant instrument setup. In the Station Configuration window select the following options for Type-C PDO test support (Refer to Figure 1): 1 Check the option Test Type-C PDOs. 2 Choose a power supply. The main options are: N6786A: The N6786A is suitable for testing sink and source up to 20V. 5V Power Supply: The simple 5V power supply is just to bring a DUT to work, but not to test any PDOs. It maybe any fixed 5V supply with current capability sufficient for the DUT. The recommended minimum is 500mA.

8 2 ValiFrame Station Configuration USB Figure 1 ValiFrame Station Configuration wizard To choose the 5V power supply, select None as power supply. In this case, ValiFrame will not try to configure the power supply during the tests (for example, for link training or loop back purposes). The other options are: E3631A, E363xA, E364xA and N67xx. For a full featured PDO test of USB Type-C DUT, choose N67xx. 8 Keysight N5990A Type-C Extension User Guide

9 ValiFrame Station Configuration 2 DisplayPort Figure 2 DisplayPort Station Configuration Wizard For DisplayPort, you can choose between a Simple 5V Supply and Keysight N67xx Power Supply (Refer to Figure 2). Keysight N5990A Type-C Extension User Guide 9

10 2 ValiFrame Station Configuration Thunderbolt Figure 3 Thunderbolt Station Configuration Wizard For Thunderbolt, you can choose between Keysight N67xx and a Simple 5V supply (Refer to Figure 3). For details about the complete setup options, refer to the specific User Guide for each standard. Remote Instruments Server The Remote Instruments Server is a host server application. All information needed is packed into an installer. This installer also contains special USB driver libraries as well as the driver for N7018A. When Type-C PDO testing is enabled, the N7018A Type-C Controller will be included in the Rx setup. 10 Keysight N5990A Type-C Extension User Guide

11 ValiFrame Station Configuration 2 The Remote Instruments Server is necessary to access the N7018A. It can be installed on any machine with a MS-Windows system like a PC, laptop or a Keysight DSO. It allows connection via Ethernet to the USB port, where the N7018A is plugged in. Download it from BitifEye's ftp-site, install and run it the first time with admin rights. If you also want to use the Unigraf AUX channel controller DPT-200 and/or the Artek CLE1000 for DisplayPort-tests, you can access them remotely through this RemoteInstrumentsServer. Instrument Configuration The last step of the Station Configuration is the Instrument Configuration. In this step, you have to enter instrument addresses. For Keysight N7018A, use the address of the machine where the N7018A is connected to. NOTE The Remote Instrument Server must be installed in that machine. In the example below, the Remote Instrument Server is installed in the Keysight oscilloscope (Refer to Figure 4): Keysight N5990A Type-C Extension User Guide 11

12 2 ValiFrame Station Configuration Figure 4 Instrument Configuration with Remote Instrument Server installed in the Keysight Oscilloscope If you have connected the N7018A to the same PC where ValiFrame is running, type in the local IP address (Refer to Figure 5). Figure 5 Instrument Configuration with Remote Instrument Server installed in the same PC as ValiFrame 12 Keysight N5990A Type-C Extension User Guide

13 Keysight N5990A Type-C Extension User Guide 3 ValiFrame DUT Configuration USB / 14 DisplayPort / 18 Thunderbolt / 20 PDO Configuration / 21 After the Station is configured, perform the following steps: 1 Open the ValiFrame software of the particular application. 2 From the main window of each active application, click Configure DUT to open the corresponding Configuration Dialog window. In the Configuration Dialog Window, all test parameters can be configured, including the PDOs and other properties of the DUT's Type-C.

14 3 ValiFrame DUT Configuration USB To select the PDOs, perform the following steps (Refer to Figure 6, Figure 7 and Figure 8): 1 In the Station Configuration window, select the Test Type-C PDOs option. 2 In the Configure DUT window, select 3.1 as the Spec Version and Type-C as the connector type. 3 Select ExpertMode and click Parameters 4 In the Common Tab of the Test Parameters Window, select Power Supply as the mode under Power-Automation and Keysight N7015A as the fixture under Type-C. 5 In the Rx Super Speed tab of the Test Parameters Window, set the Loopback Training Method to Warm Reset LTSSM. Setting the Mode under Power Automation to Power Supply and the Method under Loopback Training to WarmResetLTSSM ensures that the DUT is brought into loopback while testing Lane1 and Lane2 in a single (instead of one?) run. 6 Click Select PDOs. Refer to the section PDO Configuration on page 21 for more details. 14 Keysight N5990A Type-C Extension User Guide

15 ValiFrame DUT Configuration Figure 6 USB PDO Selection Keysight N5990A Type-C Extension User Guide 15

16 3 ValiFrame DUT Configuration Figure 7 PDO Selection - Test Parameters Window 16 Keysight N5990A Type-C Extension User Guide

17 ValiFrame DUT Configuration Figure 8 PDO Selection Display Window For a description of all the other test properties, please refer to section of the "Keysight N5990A Test Automation Software Platform for USB" guide. Keysight N5990A Type-C Extension User Guide 17

18 3 ValiFrame DUT Configuration DisplayPort To select the PDOs follow the next steps (Refer to Figure 9): 1 Select the Support for Type-C PDOs option. 2 Select DPType-C as CTS Version. 3 Select Keysight N7015A as the Plug Fixture. 4 Set the Type-C PDO Configuration section. Refer to PDO Configuration on page 21 for more details. Figure 9 DisplayPort PDO Selection By default, the standard 4 lanes operation mode is selected. In this mode, 1, 2 or 4 DP lanes can be tested. 18 Keysight N5990A Type-C Extension User Guide

19 ValiFrame DUT Configuration Select the Check Box for DP 2+2 mode to enable the 2+2 lane operation mode. In this mode, two lanes of the Type-C interface are dedicated to USB3.1 (the other two are DP lanes) (Refer to Figure 10). Figure 10 DP 2+2 Mode Selected For the description of other test properties, refer to section 2.3 of the "Keysight N5990A-155 Test Automation Software Platform for Display Port" guide. Keysight N5990A Type-C Extension User Guide 19

20 3 ValiFrame DUT Configuration Thunderbolt To select the PDOs, perform the following steps (Refer to Figure 11): 1 Select the Support for Type-C PDOs option in the Station Configuration. 2 Select Keysight N7015A Test Fixture as Fixture Type. 3 Click Select PDOs to configure PDOs. Refer to the section PDO Configuration on page 21 for more information. Figure 11 Thunderbolt PDO Selection For the description of all the other test properties please refer to the section 3.2 of the "Keysight N5990A-104 Test Automation Software Platform for Thunderbolt" guide. 20 Keysight N5990A Type-C Extension User Guide

21 ValiFrame DUT Configuration PDO Configuration In the PDO Selection dialog/section, you can read out the PDOs from the DUT and select such PDOs that must be applied during the RX tests. Prior to reading the PDOs, it is necessary to configure the power supply. To do so, click Configure Power Supply (Refer to Figure 12). Figure 12 PDO Power Supply Configuration If N67xx is used, the dialog shows the available channel modules of the N67xx frame. Here, you can choose the module to use (Refer to Figure 13). In case of a simple 5V power supply, the dialog shows the configured current capability. Here, you can type in the actual current capability of the power supply. For the 5V power supply, you may use a high-power USB plug-in charger (Refer to Figure 13). Keysight N5990A Type-C Extension User Guide 21

22 3 ValiFrame DUT Configuration Figure 13 N67xx Power Module Configuration After you have configured the power supply, click Read the DUT PDOs to query the PDOs from the DUT. The PDO list displays only those PDOs, which can be supported by the currently configured power supply. For example, a consumer PDO 5V/900mA will be not displayed, if your configured power supply is only capable of 5V/500mA. To view unsupported PDOs, uncheck the Only supported PDOs check box. NOTE You can only select supported PDOs for tests. 22 Keysight N5990A Type-C Extension User Guide

23 ValiFrame DUT Configuration Figure 14 Supported PDO selection In the same dialog, you can select the configuration channel to CC1 for normal connection orientation and to CC2 for flipped orientation. If, for some reasons, you want to run tests with flipped SBU-lines, select the Flip SBU-lines check box. The SBU lines are assigned to AUX +/- in Displayport-mode and to LSTX / LSRX in Thunderbolt-mode in the right orientation, taking the CC into account (Refer to Figure 14). Keysight N5990A Type-C Extension User Guide 23

24 3 ValiFrame DUT Configuration 24 Keysight N5990A Type-C Extension User Guide

25 Keysight N5990A Type-C Extension User Guide 4 Connection Diagrams USB / 26 DisplayPort / 31 Thunderbolt / 37

26 4 Connection Diagrams USB Rx Tests with M8020A Figure 15 Rx Tests with M8020A 1 Connect the DC blocking capacitors to the M8020A data outputs. 2 Connect the blocking capacitors to the Keysight N7015A Fixture data inputs. 3 Connect the Keysight N7015A Fixture to the Keysight N7018A Type-C Test Controller. 4 Connect the Keysight N7015A Fixture data outputs to the M8020A data inputs. 5 Connect the Keysight N7015A Fixture to the DUT. 26 Keysight N5990A Type-C Extension User Guide

27 Connection Diagrams 6 Connect the N67XX Modular Power System Mainframe to the Keysight N7018A Type-C Test Controller power input 7 Terminate all the connectors as indicated. Keysight N5990A Type-C Extension User Guide 27

28 4 Connection Diagrams LFPS Rx Tests with M8020A Figure 16 LFPS Rx Tests with M8020A 1 Connect the DC blocking capacitors to the M8020A data outputs. 2 Connect the blocking capacitors to the Keysight N7015A Fixture data inputs. 3 Connect the Keysight N7015A Fixture to the Keysight N7018A Type-C Test Controller. 4 Connect the positive output of the Keysight N7015A Fixture to Oscilloscope Channel 1. 5 Connect the negative output of the Keysight N7015A Fixture to M8020A SYS IN A. 6 Connect M8020A Trig Out+ to Oscilloscope Channel 3. 7 Connect the Keysight N7015A Fixture to the DUT. 8 Connect the N67XX Modular Power System Mainframe to the Keysight N7018A Type-C Test Controller power input. 9 Terminate all the connectors as indicated. 28 Keysight N5990A Type-C Extension User Guide

29 Connection Diagrams Rx Tests with N4903B Figure 17 Rx Tests with N4903B 1 Connect N4903B Data Out+ to N4916 De-Emphasis Signal Converter Data In. 2 Connect N4903B Aux CLK Out to N4916 De-Emphasis Signal Converter CLK In. 3 Connect two DC blocking capacitors to the N4916 De-Emphasis Signal Converter data outputs. 4 Connect the blocking capacitors to the Keysight N7015A Fixture data inputs. 5 Connect the Keysight N7015A Fixture to the Keysight N7018A Type-C Test Controller. Keysight N5990A Type-C Extension User Guide 29

30 4 Connection Diagrams 6 Connect the Keysight N7015A Fixture data outputs to the N4903B data inputs. 7 Connect the Keysight N7015A Fixture to the DUT. 8 Connect the N67XX Modular Power System Mainframe to the Keysight N7018A Type-C Test Controller power input. 9 Terminate all the connectors as indicated. 30 Keysight N5990A Type-C Extension User Guide

31 Connection Diagrams DisplayPort Rx Tests with M8020A Figure 18 Rx Tests with M8020A 1 Use DC Blocks for victim aggressor lane. 2 TTCs for the victim lane: 60ps (Picoseconds Pulse Labs). 3 TTCs for the aggressor lanes: 150ps (Picoseconds Pulse Labs). Keysight N5990A Type-C Extension User Guide 31

32 4 Connection Diagrams 4 Use 3-way power dividers to generate the signals from the aggressor generator. 5 Terminate all the unused outputs of the signal generator with 50 Ohm. 32 Keysight N5990A Type-C Extension User Guide

33 Connection Diagrams Rx Tests with N4903B Figure 19 Rx Tests with N4903B 1 Use the DC Blocks for victim aggressor lane. 2 TTCs for the victim lane: 60ps Picoseconds Pulse Labs. 3 TTCs for the aggressor lanes: 150ps Picoseconds Pulse Labs. 4 Use 3-way power dividers to generate the signals from the aggressor generator. 5 Terminate all the unused outputs of the signal generator with 50 Ohm. Keysight N5990A Type-C Extension User Guide 33

34 4 Connection Diagrams Rx Tests with ParBERT 7G Figure 20 Rx Tests with ParBERT 7G 1 Use the DC Blocks for victim agressor lane. 2 TTCs for the victim lane: 60ps Picoseconds Pulse Labs. 3 TTCs for the aggressor lanes: 150ps Picoseconds Pulse Labs. 4 Use 3-way power dividers to generate the signals from the aggressor generator. 5 Terminate all the unused outputs of the signal generator with 50 Ohm. 34 Keysight N5990A Type-C Extension User Guide

35 Connection Diagrams Rx Tests for DP 2+2 mode Figure 21 Rx Tests for DP 2+2 mode 1 Use the DC Blocks for victim agressor lane. 2 TTCs for the victim lane: 60ps Picoseconds Pulse Labs. 3 TTCs for the aggressor lanes: 150ps Picoseconds Pulse Labs. Keysight N5990A Type-C Extension User Guide 35

36 4 Connection Diagrams 4 Use 3-way power dividers to generate the signals from the aggressor generator. 5 Terminate two of the power divider outputs with 50 Ohm. 6 Terminate all the unused outputs of the signal generator with 50 Ohm. 36 Keysight N5990A Type-C Extension User Guide

37 Connection Diagrams Thunderbolt Rx TP2 Tests with M8020A Figure 22 Rx TP2 Tests with M8020A 1 Connect the N5171B EXG output to the M8062A CM input 'INTERFERENCE IN / CM'. 2 Use the DC-blocking caps at the M8062A outputs. 3 Connect the M8062A data outputs to the lane under test of the fixture. The lane under test is 'Rx0'. Keysight N5990A Type-C Extension User Guide 37

38 4 Connection Diagrams 4 Connect the TBT fixture to the PortA/PortB of the DUT 5 Use the same cables and accessories that were connected for calibration. Do not disconnect them between calibrations and tests. 38 Keysight N5990A Type-C Extension User Guide

39 Connection Diagrams Rx TPEQ Tests with M8020A Figure 23 Rx TPEQ Tests with M8020A 1 Connect the N5171B EXG output to the M8062A CM input 'INTERFERENCE IN / CM'. 2 Use DC-blocking caps at the M8062A outputs. 3 Connect the M8062A data outputs to the lane under test of the fixture. The lane under test is 'Tx0'. 4 Connect the TBT fixture to the PortA/PortB of the DUT. 5 Use a Thunderbolt Type-C cable of 2m between the TBT fixture and the DUT. 6 Use the same cables and accessories that were connected for calibration. Do not disconnect them between calibrations and tests. Keysight N5990A Type-C Extension User Guide 39

40 4 Connection Diagrams 40 Keysight N5990A Type-C Extension User Guide

41 Keysight N5990A Type-C Extension User Guide 5 Calibration Procedures References / 42

42 5 Calibration Procedures References The calibration procedures for USB, Display Port and Thunderbolt Type-C are the same as for the respective technology standards. Refer to the base manual of the particular application to get relevant information about calibrating your setup: Section of the Keysight N5990A Test Automation Software Platform for USB. Chapter 5 of the Keysight N5990A-155 Test Automation Software Platform for DisplayPort. Section 5.1 of the Keysight N5990A-104 Test Automation Software Platform for Thunderbolt. 42 Keysight N5990A Type-C Extension User Guide

43 Keysight N5990A Type-C Extension User Guide 6 Rx Test Procedures PDO Iterations Node / 44

44 6 Rx Test Procedures PDO Iterations Node When at least one PDO has been selected, there will be an additional node in the test tree. This is the PDO iterations node that will contain all the receiver test procedures (Refer to Figure 24). 44 Keysight N5990A Type-C Extension User Guide

45 Rx Test Procedures 6 Figure 24 PDO Iterations Node If you select the PDO iterations node, the property panel will display information of all the selected PDOs and some configurable parameters: Do Auto Iterations through the PDO list?: If set to true, each selected PHY test will be done with each of the selected PDOs applied to the DUT. Keysight N5990A Type-C Extension User Guide 45

46 6 Rx Test Procedures The procedure is the same as that for other tests (Refer to Figure 25): 1 Select the desired set of PHY tests and start the sequencer, following which ValiFrame will automatically repeat each test for each PDO. Figure 25 Test Selection and Execution 2 Save a Workbook after each PDO step?: If set to true, for each PDO, the set of test results is saved in an HTML-workbook (Refer to Figure 26). 3 Path for auto-saved Workbooks: Set the location of the saved workbook. 46 Keysight N5990A Type-C Extension User Guide

47 Rx Test Procedures 6 Figure 26 Test Results The PDO handling method is the same for all standards (that is, USB, DP and Thunderbolt). The list of Rx tests is not affected by the selection of the PDOs. Refer to the base manual of the particular application to get relevant information about them: Section of the Keysight N5990A Test Automation Software Platform for USB. Chapter 6 of the Keysight N5990A-155 Test Automation Software Platform for Display Port. Section 5.2 of the Keysight N5990A-104 Test Automation Software Platform for Thunderbolt. Keysight N5990A Type-C Extension User Guide 47

48 6 Rx Test Procedures 48 Keysight N5990A Type-C Extension User Guide

49 Keysight N5990A Type-C Extension User Guide 7 Contact Information For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at:

50 7 Contact Information 50 Keysight N5990A Type-C Extension User Guide

51 Keysight ValiFrame Type C Extension User Guide 51

52 This information is subject to change without notice. Keysight Technologies 2017 December 30,

Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort

Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort Calibration and Test Procedure Descriptions User Guide Notices Keysight Technologies 2018 No part of this manual may be reproduced in any

More information

Keysight N5990A-155 Display Port. User Guide

Keysight N5990A-155 Display Port. User Guide Keysight N5990A-155 Display Port User Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

Keysight N5990A Test Automation Software Platform

Keysight N5990A Test Automation Software Platform Keysight N5990A Test Automation Software Platform Installation Guide Notices Copyright Notice Keysight Technologies 2016 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight E7515A UXM Firmware Update Tool

Keysight E7515A UXM Firmware Update Tool Keysight E7515A UXM Firmware Update Tool For the E7515A UXM Wireless Test Set Installation & User Guide Notices Keysight Technologies, Inc. 2014-2017 No part of this manual may be reproduced in any form

More information

Keysight N7015A/16A Type-C Test Kit. User Guide

Keysight N7015A/16A Type-C Test Kit. User Guide Keysight N7015A/16A Type-C Test Kit User Guide Notices Keysight Technologies 2015, 2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Keysight N5990A-104 Test Automation Software Platform for Thunderbolt. User Guide

Keysight N5990A-104 Test Automation Software Platform for Thunderbolt. User Guide Keysight N5990A-104 Test Automation Software Platform for Thunderbolt User Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter Quick Start Guide Keysight GUI Data Logger Software Quick Start Guide 3 Notices Copyright Notice Keysight Technologies

More information

Keysight N5990A-301 PCI Express Link Training Suite. User Guide

Keysight N5990A-301 PCI Express Link Training Suite. User Guide Keysight N5990A-301 PCI Express Link Training Suite User Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables Operations and Installation Manual Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables Notices Keysight Technologies, Inc. 1987-2016 No part of this manual may be reproduced in any form or by any

More information

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Keysight N5191A/93A UXG X-Series Agile Signal Generator Keysight N5191A/93A UXG X-Series Agile Signal Generator Security Features and Document of Volatility Notices Copyright Notice Keysight Technologies 2014-2019 No part of this manual may be reproduced in

More information

Keysight DSOXT3NFC/ DSOX4NFC Near Field Communication Test Application

Keysight DSOXT3NFC/ DSOX4NFC Near Field Communication Test Application Keysight DSOXT3NFC/ DSOX4NFC Near Field Communication Test Application Online Help Notices Keysight Technologies, Inc. 2006-2016 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1987-2015 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent OBSAI Protocol Tester

Agilent OBSAI Protocol Tester Agilent OBSAI Protocol Tester Hardware Reference Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent N5394A DVI Electrical Performance Validation and Compliance Software

Agilent N5394A DVI Electrical Performance Validation and Compliance Software Agilent N5394A DVI Electrical Performance Validation and Compliance Software Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2004-2008 No part of this

More information

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1988-2015 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) EZChrom Edition Reusing EZChrom Data in OpenLAB CDS with Data Store or ECM Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced

More information

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application Keysight N108xA-Series IEEE 802.3 Ethernet KR/CR Compliance and Debug Application Getting Started Notices Keysight Technologies, Inc. 2014 No part of this manual may be reproduced in any form or by any

More information

Keysight Combiner and Mechanical Switches Upgrade Kit

Keysight Combiner and Mechanical Switches Upgrade Kit Keysight Combiner and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5247A/B Option 419 to Option 423 Upgrade Kit Order Number: N5247AU-927 and N5247BU-423 Keysight Kit Number: N5247-60104 Installation

More information

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies Agilent 34826A BenchLink Data Logger for 34980A Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including

More information

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means

More information

Firmware Guide. Keysight PXIe Chassis Family

Firmware Guide. Keysight PXIe Chassis Family Firmware Guide Keysight PXIe Chassis Family Notices Keysight Technologies, Inc. 2018 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

Agilent ChemStation Plus

Agilent ChemStation Plus Agilent ChemStation Plus Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Agilent 1260 Infinity Purification Solution

Agilent 1260 Infinity Purification Solution Agilent 1260 Infinity Purification Solution Administrator's Quick Start Guide Agilent Technologies Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced in any form or by any

More information

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit Keysight 11878A 50 Ohm 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1989, 2004, 2013, 2014 No part of this manual may be reproduced in any form or by any means (including

More information

Agilent CSV Export Utility

Agilent CSV Export Utility Agilent CSV Export Utility User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures. Agilent SureCall 3.5 Installation Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2016 No part of this manual may be reproduced

More information

Keysight MIPI M-PHY Command Line Packet Generator. User s Guide

Keysight MIPI M-PHY Command Line Packet Generator. User s Guide Keysight MIPI M-PHY Command Line Packet Generator User s Guide Notices Keysight Technologies 2014-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Keysight J-BERT M8020A High-Performance BERT and M8030A Multi-Channel BERT. Getting Started Guide

Keysight J-BERT M8020A High-Performance BERT and M8030A Multi-Channel BERT. Getting Started Guide Keysight J-BERT M8020A High-Performance BERT and M8030A Multi-Channel BERT Getting Started Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means

More information

Keysight N5392B/N5392C Ethernet Compliance Test Application. Methods of Implementation

Keysight N5392B/N5392C Ethernet Compliance Test Application. Methods of Implementation Keysight N5392B/N5392C Ethernet Compliance Test Application Methods of Implementation Notices Keysight Technologies 2015-2017 No part of this manual may be reproduced in any form or by any means (including

More information

Agilent N5410A Fibre Channel Automated Test Application

Agilent N5410A Fibre Channel Automated Test Application Agilent N5410A Fibre Channel Automated Test Application Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced

More information

Agilent G2721AA/G2733AA

Agilent G2721AA/G2733AA Agilent G2721AA/G2733AA Spectrum Mill MS Proteomics Workbench Site Preparation Guide Notices Agilent Technologies, Inc. 2001-2012 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight SAS Link Training. User Guide

Keysight SAS Link Training. User Guide Keysight SAS Link Training User Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

Agilent Series Logic Analysis System

Agilent Series Logic Analysis System Agilent 16900-Series Logic Analysis System Quick Start Guide for 16700-Series Users Agilent Technologies Notices Agilent Technologies, Inc. 2003-2004 No part of this manual may be reproduced in any form

More information

Agilent OpenLAB. Data Store. Backup and Restore Guide

Agilent OpenLAB. Data Store. Backup and Restore Guide Agilent OpenLAB Data Store Backup and Restore Guide Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Keysight Software. Installation Guide

Keysight Software. Installation Guide Keysight 89600 Software Installation Guide Notices Copyright Notice Keysight Technologies 2000-2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect Hardware Setup Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form

More information

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11 BIT-3000 Dynamic Sequencing Generator and Analyzer Datasheet 1.11 BitifEye Digital Test Solutions GmbH Herrenberger Strasse 130 71034 Boeblingen, Germany info@bitifeye.com www.bitifeye.com Notices BitifEye

More information

Keysight U2722A/U2723A USB Modular Source Measure Units

Keysight U2722A/U2723A USB Modular Source Measure Units Keysight U2722A/U2723A USB Modular Source Measure Units Service Guide Notices Copyright Notice Keysight Technologies 2009-2017 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Operating and Service Manual Notices Keysight Technologies 1985, 2013, 2014 No part of this manual may be reproduced in any form or by any means

More information

Agilent ChemStation Plus

Agilent ChemStation Plus Agilent ChemStation Plus Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2006-2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent Technologies E5385A 100-Pin Probe

Agilent Technologies E5385A 100-Pin Probe Agilent Technologies E5385A 100-Pin Probe Installation Note The Agilent Technologies E5385A 100-pin probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a

More information

Agilent OpenLAB. Data Store. Maintenance Guide

Agilent OpenLAB. Data Store. Maintenance Guide Agilent OpenLAB Data Store Maintenance Guide Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

User s Guide. Keysight W2635A and W2636A DDR3 BGA Probe Adapters for Oscilloscopes

User s Guide. Keysight W2635A and W2636A DDR3 BGA Probe Adapters for Oscilloscopes User s Guide Keysight W2635A and W2636A DDR3 BGA Probe Adapters for Oscilloscopes Notices Keysight Technologies, Inc. 2007, 2008, 2015 No part of this manual may be reproduced in any form or by any means

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition Reusing Data from ChemStation B.04.03 SP1 and SP2 in OpenLAB CDS ChemStation Edition Notices Agilent Technologies, Inc. 2012-2013, 2014

More information

86100 Series Infiniium DCA Oscilloscope

86100 Series Infiniium DCA Oscilloscope 86100 Series Infiniium DCA Oscilloscope This manual provides the documentation for the following instruments 86100D 86100C User s Manual Notices Keysight Technologies, Inc. 20xx-2014 No part of this manual

More information

Agilent OpenLAB Chromatography Data System

Agilent OpenLAB Chromatography Data System Agilent OpenLAB Chromatography Data System EZChrom Elite Edition Migration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by

More information

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 1987, 2004, 2008 No part of this manual may be reproduced in any form

More information

Agilent W2100 Antenna Modeling Design System

Agilent W2100 Antenna Modeling Design System Agilent W2100 Antenna Modeling Design System Release Notes Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent Dissolution Tester Driver

Agilent Dissolution Tester Driver Agilent Dissolution Tester Driver Agilent Technologies Notices Agilent Technologies, Inc. 2011-2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005, 2007 No part of this manual may be reproduced in any form

More information

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A, N5242A, or N5249A Option 219 to Option 224 For Analyzers with Serial Numbers Prefixed MY/SG/US5150 and Below

More information

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies Agilent Lab Advisor IT Administrator's Guide Agilent Technologies Notices Agilent Technologies, Inc. 2016 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5247A/B Option 219 to Option 224 Upgrade Kit Order Number: N5247AU-922 and N5247BU-224 Keysight Kit Number: N5247-60102

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition AIC (M8304AA) Setup Guide Agilent Technologies Notices Agilent Technologies, Inc. 2010-2014, 2015 No part of this manual may be reproduced

More information

BenchCel Workstations Software

BenchCel Workstations Software BenchCel Workstations Software User Guide For Research Use Only. Not for use in diagnostic procedures. Original Instructions Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced

More information

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable Installation Note The 38-pin probe and adapter cable provide a convenient way to connect two Agilent Technologies logic analyzer

More information

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide Notices Keysight Technologies 2013-2014 No part of this manual may be reproduced in any form or by any means (including

More information

Agilent OpenLAB Chromatography Data System

Agilent OpenLAB Chromatography Data System Agilent OpenLAB Chromatography Data System EZChrom Edition EZChrom Elite and ICM Migration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) Hardware and Software Requirements Agilent Technologies Notices Agilent Technologies, Inc. 2013-2014 No part of this manual may be reproduced in any form

More information

Agilent CytoGenomics 2.5

Agilent CytoGenomics 2.5 Agilent CytoGenomics 2.5 Installation and Administration Guide Research Use Only. Not for Diagnostic Procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may

More information

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide Agilent OpenLAB Data Analysis Upload Download Tool User s Guide Notices Agilent Technologies, Inc. 2014 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Agilent InfiniiMax II 1168A/1169A Probes

Agilent InfiniiMax II 1168A/1169A Probes Agilent InfiniiMax II 1168A/1169A Probes Handling Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) EZChrom Edition Compatibility Guide for Agilent Instrument Controllers Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual

More information

Agilent Gb/s Serial BERT

Agilent Gb/s Serial BERT Agilent 3.125 Gb/s Serial BERT N5980A Programming Guide Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Errata. Agilent References in this manual. About this manual. Support for your product

Errata. Agilent References in this manual. About this manual. Support for your product Errata Agilent References in this manual NOTICE: This document contains references to Agilent Technologies. Agilent s former Test and Measurement business has become Keysight Technologies. For more information,

More information

Agilent E2094M IO Libraries

Agilent E2094M IO Libraries Agilent E2094M IO Libraries Agilent IO Libraries Installation and Configuration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or

More information

Keysight M9393A PXIe Vector Signal Analyzer

Keysight M9393A PXIe Vector Signal Analyzer Security Guide Keysight M9393A PXIe Vector Signal Analyzer. Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become Keysight Technologies.

More information

Agilent OpenLAB Data Store Administration. Guide for Administrators

Agilent OpenLAB Data Store Administration. Guide for Administrators Agilent OpenLAB Data Store Administration Guide for Administrators Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

DDR/LPDDR Custom Configuration Creator Tool. User s Guide DDR/LPDDR Custom Configuration Creator Tool User s Guide Notices Keysight Technologies 2008-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent OpenLAB Data Store. Maintenance Guide

Agilent OpenLAB Data Store. Maintenance Guide Agilent OpenLAB Data Store Maintenance Guide Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies Agilent Technologies USB/LAN/GPIB Interfaces Connectivity Guide Agilent Technologies Notices Agilent Technologies, Inc. 2003-2006 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight M8085A MIPI D-PHY Editor. User Guide

Keysight M8085A MIPI D-PHY Editor. User Guide Keysight M8085A MIPI D-PHY Editor User Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies Agilent M9502A and M9505A AXIe Chassis Firmware Revision Firmware Update Guide Agilent Technologies i Notices Agilent Technologies, Inc. 2011, 2012, 2014 No part of this manual may be reproduced in any

More information

Agilent EZChrom SI. Startup Guide

Agilent EZChrom SI. Startup Guide Agilent EZChrom SI Startup Guide Notices Copyright Scientific Software, Inc 2003 Agilent Technologies, Inc. 2006. No part of this manual may be reproduced in any form or by any means (including electronic

More information

Keysight Add 4-Port Capability Upgrade Kit

Keysight Add 4-Port Capability Upgrade Kit Keysight Add 4-Port Capability Upgrade Kit To Upgrade PNA-X N5244B or N5245B Option 217 to Option 417 For Analyzers with Serial Numbers Prefixed MY/SG/US5201 and Above Upgrade Kit Order Number: N5244BU-617

More information

Agilent 89600B VSA. Software Installation Guide

Agilent 89600B VSA. Software Installation Guide Agilent 89600B VSA Software Installation Guide Notices Agilent Technologies, Inc. 2000-2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent OpenLAB ECM Intelligent Reporter

Agilent OpenLAB ECM Intelligent Reporter Agilent OpenLAB ECM Intelligent Reporter Installation and Configuration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007-2016 No part of this manual may be reproduced in any form or by

More information

Keysight N5990A-302 USB Link Training Suite

Keysight N5990A-302 USB Link Training Suite Keysight N5990A-302 USB Link Training Suite User Guide Notices Keysight Technologies, Inc. 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Microscan Barcode Reader

Microscan Barcode Reader Microscan Barcode Reader Device Driver Guide For Research Use Only. Not for use in diagnostic procedures. Original Instructions Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced

More information

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide Keysight 54006A 6 GHz Passive Divider Probe Kit User s Guide Notices Keysight Technologies, Inc. 1988-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A, N5242A, or N5249A Option 419 to Option 423 Upgrade Kit Order Number: N5241AU- 927, N5242AU- 927, and N5249AU-

More information

Errata. Agilent References in this manual. About this manual. Support for your product

Errata. Agilent References in this manual. About this manual. Support for your product Errata Agilent References in this manual NOTICE: This document contains references to Agilent Technologies. Agilent s former Test and Measurement business has become Keysight Technologies. For more information,

More information

Agilent N4880A. Reference Clock Multiplier. User s Guide

Agilent N4880A. Reference Clock Multiplier. User s Guide Agilent N4880A Reference Clock Multiplier User s Guide Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Setting Up Probes. Online Help

Setting Up Probes. Online Help Setting Up Probes Online Help Notices Agilent Technologies, Inc. 2001-2009 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

Keysight Add Source and Receiver Attenuators Upgrade Kit

Keysight Add Source and Receiver Attenuators Upgrade Kit Keysight Add Source and Receiver Attenuators Upgrade Kit To Upgrade PNA N5221A or N5222A Option 401 to Option 417 Upgrade Kit Order Numbers: N5221AU-417 or N5222AU-417 Keysight Kit Number: N5222-60107

More information

Quick Start/Installation Guide

Quick Start/Installation Guide Agilent Technologies E5850A Time Correlation Fixture Quick Start/Installation Guide The Agilent E5850A time correlation fixture allows you to make time-correlated measurements between a 1680/90 or 16700

More information

Agilent ChemStation for UV-visible Spectroscopy

Agilent ChemStation for UV-visible Spectroscopy Agilent ChemStation for UV-visible Spectroscopy Understanding Your Biochemical Analysis Software Agilent Technologies Notices Agilent Technologies, Inc. 2000, 2003-2008 No part of this manual may be reproduced

More information

Agilent 34970A BenchLink Data Logger 3

Agilent 34970A BenchLink Data Logger 3 Agilent 34970A BenchLink Data Logger 3 Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight Software

Keysight Software Keysight 89600 Software Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become Keysight Technologies. For more information, go to www.keysight.com.

More information

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT. Getting Started with the Agilent Serial BERT N4906B You only need a few minutes to get started with the Serial BERT. This Getting Started Brochure helps you to quickly understand the operating principles

More information

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Agilent E4418/19A Power Meter Hardware Upgrade Kit Agilent E4418/19A Power Meter Hardware Upgrade Kit (E9300 Compatible) Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form

More information

Agilent Flowmeter ADM2000

Agilent Flowmeter ADM2000 Agilent Flowmeter ADM2000 Operating Instructions Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent ChemStation. ECM Interface Guide. Agilent Technologies Agilent ChemStation ECM Interface Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2005-2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

U4431 MIPI M-PHY Protocol Analyzer. User Guide

U4431 MIPI M-PHY Protocol Analyzer. User Guide U4431 MIPI M-PHY Protocol Analyzer User Guide Notices Agilent Technologies, Inc. 2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

Keysight U4421A MIPI D-PHY Protocol Analyzer and Exerciser. Hardware and Probing Guide

Keysight U4421A MIPI D-PHY Protocol Analyzer and Exerciser. Hardware and Probing Guide Keysight U4421A MIPI D-PHY Protocol Analyzer and Exerciser Hardware and Probing Guide Notices Keysight Technologies 2012-2015 No part of this manual may be reproduced in any form or by any means (including

More information

Teledyne LeCroy. Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing

Teledyne LeCroy. Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing Teledyne LeCroy DisplayPort Standard April, 2016 Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing This document is provided "AS IS" and without any warranty of any kind, including, without

More information

Agilent N5393B PCI Express Automated Test Application

Agilent N5393B PCI Express Automated Test Application Agilent N5393B PCI Express Automated Test Application Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2004-2009 No part of this manual may be reproduced

More information

Agilent U2941A Parametric Test Fixture

Agilent U2941A Parametric Test Fixture Agilent U2941A Parametric Test Fixture Operating Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Keysight N7018A Type-C Test Controller. Data Sheet

Keysight N7018A Type-C Test Controller. Data Sheet Keysight N7018A Type-C Test Controller Data Sheet 02 Keysight N7018A Type-C Test Controller - Data Sheet Table of Contents Designed for Debug, Compliance and Full Design Validation...04 Debug Features...06

More information

Keysight U1610/20A Handheld Digital Oscilloscope. Quick Start Guide

Keysight U1610/20A Handheld Digital Oscilloscope. Quick Start Guide Keysight U1610/20A Handheld Digital Oscilloscope Quick Start Guide Contacting Keysight www.keysight.com/find/assist (worldwide contact information for repair and service) Safety and EMC Information This

More information