Dual Axis Vertical Reference System
|
|
- Mervyn Nelson
- 5 years ago
- Views:
Transcription
1 Dual Axis Vertical Reference System Owner s Manual PART NUMBER: VRS-S232-1AD WATSON INDUSTRIES, INC MELBY STREET EAU CLAIRE, WI Phone: (715) FAX: (715) support@watson-gyro.com 1
2 Table of Contents Introduction... 3 Product Description... 3 Installation... 3 Orientation:...3 Mounting:...3 Environment:...3 Power:...4 Theory of Operation... 4 Operation... 5 Special Operation Modes...5 Reference Mode...5 Free Mode...5 Specifications... 6 Analog Output... 7 RS-232 Digital Output... 7 RS-232 Output Format... 7 RS-232 Input Commands... 8 Connections... 9 Dimensions WARNING DISCLAIMER WARRANTY PRODUCT LIFE Customer Service Determining and Setting Output Channels...13 Setting Output Format...14 Appendix B Watson Industries prides itself on solving customer problems and serving their needs in a timely fashion. This manual is intended to facilitate this goal and to provide written information about your product. We ask that you carefully read this manual. Becoming familiar with the manual will help you understand the product s capabilities and limitations, as well as provide you with a basic understanding of its operation. If, after reading the manual, you require further assistance, do not hesitate to call Watson Industries with your questions and comments. CAUTION! Watson Sensors are rugged devices that have been used successfully in a number of harsh environments. The components have been qualified to withstand a mechanical shock of 1000g 's or greater, and most enclosures provide near that level of protection. However, dropping a sensor from waist height onto a hard floor can cause a shock level of 600g's. At this level, given some resonance, damage is possible. 2
3 Introduction The Watson Industries Vertical Reference represents a significant advancement in inertial sensor technology. It is a highly accurate and rugged device with many advantages over other types of angular rate and incline-sensing devices. This manual describes operation of the Watson Industries Vertical Reference and also provides useful application information to the system designer. Product Description The Watson Industries Vertical Reference System (VRS) is an entirely solid-state sensor that provides exceptional rejection from the adverse effects of inertia and short-term lateral accelerations. It does this through the use of both an accelerometer based vertical reference and an angular rate sensor which is integrated to provide additional information on angular position. It can be a functional replacement for mechanical gyros which are often more expensive and which cannot provide the reliability of a solid-state sensor. Theory of operation is described with more detail on page 4. The specifications, size and pinouts are described later in this document The Watson Vertical References provide for two types of analog output voltages. One is proportional to angular rate and the other is proportional to angular displacement. Full-scale analog outputs produce an output of ±10 volts dependent upon the direction of angular position or rotation. During rotation, positive voltage output occurs in the direction of the rotational arrow on the case. At horizontal and zero angular rotation rate, both outputs for displacement and rotation rate are near zero. A power supply, providing +10 to +30 Volts DC, is required to operate the unit. Special options in power supply, output voltage, scale calibration, and special packaging are available as custom units. Pricing and delivery information on custom units is available by contacting the factory. Installation Orientation: The base plate of the unit is to be mounted on top of a horizontal surface with the connector toward the forward direction of the vehicle. The VRS drawing, with wire call outs, is located in Figure 2. The VRS is a rugged device and will withstand harsh environments. However, due attention needs to be paid to the nature of the sensor and its prime function, which is to measure attitude and motion. Mounting: The unit has four 0.15 diameter mounting holes for using 6-32 screws. A mounting plate is provided for a flat surface mount. The unit may be adhesively mounted at any of its surfaces. If high shock loads are expected, greater than 10G or repeated shocks greater than 5G, the appropriate shock mounting should be used to prevent damage. Vibration environments of over 2.5 G rms would also require shock mounts or vibration isolation. Environment: Avoid mounting sites that are subject to significant temperature variation over the duration of the test. Temperature variation will induce significant rate sensor bias drift, which will reflect in poor attitude accuracy. 3
4 For shipboard applications, install the sensor near the center of gravity. For all applications, it is preferable to install the device where linear dynamic effects are minimized. Power: This unit has an internal regulator to allow operation over a wide voltage input range. Best operation is obtained at either +12 or +24 VDC level, although operation is fully satisfactory down to +10 VDC and up to +30 VDC. The power ground is isolated from the signal ground. Power consumption of the unit is 1.8W. The VRS power system is isolated from the VRS signal system. Internal capacitors are provided to remove a reasonable level of power line noise, however, capacitors should be added for long power line wiring or if noise is induced from other loads on the circuit. Theory of Operation In order to obtain an accurate signal in both the short-term and in the long-term, the Vertical Reference relies upon a Watson Industries angular rate sensor (ARS) combined with solid-state accelerometers. The position output is generated by integrating the angular rate output. This signal is compared with the output from the accelerometer and the resultant error signal is passed through a long time constant filter and fed back as a bias to the rate sensor. The system is damped by sending a portion of the error directly to the position integrator. By using a long time constant, the effect of the short-term errors in the accelerometer is minimized. Thus, the adverse effects of inertia, damping and short-term lateral accelerations on the pendulum essentially do not show up on the vertical reference output. See Figure 1 for system overview. The solid-state angular rate sensor used here works on the basic principle of detecting coriolis forces. These forces are generated when a moving particle is rotated. To use the coriolis effect to detect angular rotation, a solid structure is forced to vibrate normally at its resonant frequency. The vibration provides the structure with a linear velocity component. When the structure is rotated, the coriolis forces cause the vibration motion of the structure to be coupled to another vibration mode or plane of the structure. The magnitude of this secondary vibration is proportional to the angular rate of turn. 4
5 Operation In normal operation, the VRS takes data from its internal rate sensors and integrates them in a closed loop system, with the accelerometers as a long-term reference, to generate the Bank, and Elevation data. In most cases, these algorithms provide for very stable and accurate output signals; however, the user should be aware that exceeding the normal ranges of the sensors would affect accuracy. For example, while custom VRS units may have differing ranges, the rate gyros in a typical VRS have a maximum rate of 100 /s. Care should be taken not to exceed this rate because the closed loop system will receive inaccurate rate data. This will result in errors in the angle output signals. Special Operation Modes Reference Mode This mode is usually used for calibration or diagnostics. When in reference mode, the VRS will output data generated directly from the sensor reference signals rather than as a product of the closed loop integration used for normal operation. The reference command provides the same sensor information as in normal operation mode with the following differences: Bank and Elevation are obtained directly from the accelerometers - no gyro stabilization. Angular Rate Sensors are not close-loop bias corrected. The reference mode can be selected either through the terminal mode, or by an analog logic command. Note that reference mode is never a default setting. It must be re-selected when repowering the unit. Free Mode While in Free Mode, the VRS will output data from the sensors without correction by the references. For example, the Bank Angle data output in Free Mode is calculated directly from the X-axis Rate Sensor. In this case, the angle is a direct integration of the roll rate. Free Mode can be used to totally reject effects from dynamic accelerations, but accuracy degrades with time. It is intended for use over periods of a few minutes at a time. This mode provides similar sensor information as in normal operation mode with the following differences: Bank and Elevation are obtained directly from the rate gyros. Angular Rate Sensors are not close-loop bias corrected. Free mode can be accessed either through terminal mode, or by an analog logic command. Note that free mode is never a default setting. It must be re-selected when re-powering the unit. The user should not enter free mode until after the VRS is initialized and its readings are stable. 5
6 Specifications Attitude Range: Bank ±180 (±30 ) Digital (Analog) Range: Elevation ±90 (±30 ) Digital (Analog) Resolution: 0.02 Binary mode (14 bit) Analog Scale Factor: 3 /V ±10V Output Accuracy: Static ±0.5 (up to 75 ) * Accuracy: Dynamic ±2% Angular Rate Range: Roll, Pitch ±100 /sec Resolution: /sec Binary mode (14 bit) Analog Scale Factor: 10 /sec/v ±10V Output Scale Factor Accuracy: 2% Bias: Roll, Pitch < 0.3 /sec Non-Linearity < 0.05% Full scale range Bandwidth 20 Hz Acceleration Range: X, Y, Z ±10g Resolution: 4mg Scale Factor Accuracy: 1% Bias: X, Y, Z < 10mg Non-Linearity: 0.1% Full scale range Bandwidth: 20 Hz Environmental Temperature: Operating -40 C to +85 C Temperature: Storage -55 C to +85 C Vibration: Operating 2.5g rms 20 Hz to 2 khz Vibration: Survival 10g rms 20 Hz to 2 khz Shock: Survival 500g 10ms ½ sine wave Electrical Frame Rate Hz Maximum Startup Time: Data 5 sec Startup Time: Fully operational 10 sec Input Power: 10 to 30VDC 1.8W Input Current: 12VDC 24VDC Digital Output RS-232 Analog Output ±10VDC Analog Output Impedance: 300 Ohm Per line Physical Axis Alignment: < 0.25 Size: Including Mounting Flanges 3.24 W x 5.78 L x 2.38 H 8.2 x 14.7 x 6.0 (cm) Weight: 21oz (1.3lb) 590g (0.59kg) Connection: RS-232 / Analog Outputs 9 pin female D subminiature Connection: Power 9 pin male D subminiature * Actual accuracy can be calculated as the listed percentage multiplied by the change in value over the entire dynamic maneuver. Specifications are subject to change without notice 6
7 Analog Output Analog signals are output from a 12 bit digital to analog converter through an operational amplifier. Each analog output has a 300 ohm resistor in series to eliminate oscillations from high capacitance loads. The output range for all of the analog output channels is ±10 Volts with respect to the common signal ground. The analog outputs can be found on the 9-pin female D-Sub connector. The outputs include: Signal Pin Range Output Range 0 VDC Scale Factor Bank 6 ±30 ±10V 0 3 /V Elevation 7 ±30 ±10V 0 3 /V Roll Rate (X Axis) 8 ±100 /s ±10V 0 /s 10 /s/v Pitch Rate (Y Axis) 9 ±100 /s ±10V 0 /s 10 /s/v Note that the analog switches are disabled after certain serial commands are sent to the unit. This prevents software/hardware switch conflicts. RS-232 Digital Output The Digital RS-232 outputs can be found on the 9-pin female D-Sub. The Digital output pin map can be found on page 9. The RS-232 signals are referenced to the Signal Ground. The digital connections are: 1. RXD is the data receive line pin 3. The commands are sent to unit on this line. 2. TXD is the data transmit line pin 2. User Receives data on this line. 3. Signal Ground for RS-232 signals is on pin 5. RS-232 Output Format The nominal RS-232 output on the 9-pin female connector consists of a string of decimal ASCII characters sent asynchronously at regular intervals at about strings per second. The string is sent at 9600 baud with eight data bits, one stop bit and no parity. The contents of a typical string are formed as follows: (See Appendix A for information on how to change the data string.) 1. A single letter and a space used to indicate the start of the data string. The letter I indicates the start of an inertial data string. The letter R indicates the start of a Reference data string. If the letter is in lower case ( i or r ), an error over-range condition is indicated (see below). 2. A seven character string representing the bank angle starting with a space, then a + or a -, followed by three digits, a decimal point and one digit and for up to ±179.9 degrees. 3. A six character string representing the elevation angle starting with a space, then a + or a -, followed by two digits, a decimal point and one digit for up to ±89.9 degrees. 4. A six character string representing the X axis angular rate starting with a space, then a + or a -, followed by two digits, a decimal point and one digit for up to ±99.9 /second. 7
8 5. A five character string representing the Y axis angular rate starting with a space, then a + or a -, followed by two digits, a decimal point and one digit for up to ±99.9 /second. 6. The string is terminated by a carriage return. There will then be a short interval with no data transmission before the next string begins. Example: I <CR> bank angle (2) elev. angle (3) X axis Rate (4) Y axis rate (5) (6) space space space space (1) This may be reduced to attitude and heading information to improve the update rate to almost twice the previous rate by using special commands to modify the EEPROM of the unit. More channels are available for output see Appendix A. The system is protected from inadvertent write-over of the EEPROM by requiring two spacebar commands during the initialization interval to access the EEPROM or related functions. The baud rate may be changed from the nominal value of 9600 baud by modifying the default value in the EEPROM of the unit to 38400, 19200, or 4800 baud. A text header that is sent by the VRS during initializations identifies the unit by part number and by serial number and gives the date of last calibration. Additionally, a line of text characters that identifies the data channel columns is sent if the serial output is set to ASCII decimal. This whole message can be temporarily or permanently suppressed or restored by a * command from the interfacing computer. Data transmission sent by the VRS can also be suppressed or restored by a + command from the interfacing computer. The error over range condition is indicated by the use of a lower case i or r when the calculated attitude error exceeds the ranges listed above. Internal functions that require these error values are disabled while the condition exists. The system will continue to operate in an extended time constant mode with a low level of error accumulation until the condition is cleared. Occasional blips of this condition are expected with no detectable affect on the resulting data. The other output format available is a binary format. The binary format provides generally the same information as the decimal ASCII format, but in a compact binary file format. In this format, there are nominally 9 bytes sent that represent 4 fourteen-bit output channels followed by a carriage return. Again, this may be reduced to attitude information to improve the update rate (in this case the rate would be Hz) by using special commands to modify the EEPROM of the unit. This format is for highly experienced users only. Consult the factory for further details. RS-232 Input Commands The RS-232 input commands are provided for the purpose of unit test and installation set-up. The same parameters are used as for the output (9600 baud ASCII nominal, or as reset in the units EEPROM). There are eight commands intended for use by the user (others are used at the factory for alignment and calibration). 8
9 1. An R or r will set the outputs (analog and serial) to their Reference Command modes. This mode is used in installation to physically align the unit. Double spacebar at initialization is required for access to this command. 2. An I or i will clear the Reference Command mode if it had been set by the serial input. This is the default mode at power up and is the normal operating mode. Double spacebar at initialization is required for access to this command. 3. An F will disconnect the references from the attitude system and is the Coast Mode Command. This coast mode is used to make the system ignore the references during high maneuvers and brief disturbances. This mode is not intended for use except in brief intervals, since errors will grow geometrically. 4. A K will clear the Coast Mode Command. 5. An! will reinitialize the unit. Further, the access to initialization is inhibited such that a spacebar command must be sent within 5 seconds of the! command for initialization to be engaged. There are two output format serial commands: _ for decimal output and ^ for binary. See second part of Appendix A for more information on change output formats. There are several interface commands as well: : will toggle the output to send a frame of data upon receiving any non-command character and + will toggle the output for no output data. These and other changes are made non-volatile in the unit on EEPROM by keying in the quote ( ) character. Double spacebar at initialization is required for access to these commands. The & command calls a menu which allows any of several parameters to be set. These are system time constants, selection of data channels for serial output and baud rate. Double spacebar at initialization is required for access to this command. The commands #, $, (, ), {, },, <, > and? are used by the Watson factory to calibrate the unit and should be used only with the assistance of the factory. If an undesired function is called, a Q, and sometimes Escape or a Delete will interrupt the command and return to operation with the least disturbance to the system. All other unspecified characters such as carriage return, line feed and space are ignored by the system. If there are problems with the system hanging up during the binary output mode, check for crosstalk between the serial transmit and receive line in your installation. In addition, check to see that the communications program used is not sending an echo. This will not happen in the decimal or hexadecimal modes because command characters recognized by the system are not produced in those modes. Connections 9 Pin Male Power Connector Pin Description 1 Power Ground to + 30 VDC 3-9 No Connection 9
10 9 Pin Female RS-232/Analog Output Connector Pin Description 1 No Connection 2 RS-232 TXD 3 RS-232 RXD 4 No Connection 5 Signal Ground 6 Bank (X) Angle Analog Output 7 Elevation (Y) Angle Analog Output 8 X Angular Rate Analog Output 9 Y Angular Rate Analog Output The RS-232 serial and analog output connections are referenced to Signal Ground on pin 5. Dimensions Z X FORWARD Y Y REV. P/N S/N PWR. S.F. WATSON IND., INC. EAU CLAIRE, WI USA support@watson-gyro.com INTERNATIONALLY PATENTED AND PATENTS PENDING CAUTION DELICATE INSTRUMENT HANDLE WITH CARE 10
11 WARNING Rough handling or dropping of this unit is likely to cause damage. Over-voltage and/or miswiring of this unit will cause damage. This unit should be protected against prolonged exposure to high humidity and/or salt air environments. DISCLAIMER The information contained in this manual is believed to be accurate and reliable; however, it is the user s responsibility to test and to determine whether a Watson Industries product is suitable for a particular use. Suggestion of uses should not be taken as inducements to infringe upon any patents. WARRANTY Watson Industries, Inc. warrants, to the original purchaser, this product to be free from defective material or workmanship for a period of two full years from the date of purchase. Watson Industries liability under this warranty is limited to repairing or replacing, at Watson Industries sole discretion, the defective product when returned to the factory, shipping charges prepaid, within two full years from the date of purchase. The warranty described in this paragraph shall be in lieu of any other warranty, express or implied, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. Excluded from any warranty given by Watson Industries are products that have been subject to abuse, misuse, damage or accident; that have been connected, installed or adjusted contrary to the instructions furnished by seller; or that have been repaired by persons not authorized by Watson Industries. Watson Industries reserves the right to discontinue models, to change specifications, price or design of this product at any time without notice and without incurring any obligation whatsoever. The purchaser agrees to assume all liabilities for any damages and/or bodily injury that may result from the use, or misuse, of this product by the purchaser, his employees or agents. The purchaser further agrees that seller shall not be liable in any way for consequential damages resulting from the use of this product. No agent or representative of Watson Industries is authorized to assume, and Watson Industries will not be bound by any other obligation or representation made in connection with the sale and/or purchase of this product. PRODUCT LIFE The maximum expected life of this product is 20 years from the date of purchase. Watson Industries, Inc. recommends the replacement of any product that has exceeded the product life expectation. 11
12 Customer Service All repairs, calibrations and upgrades are performed at the factory. Before returning any product, please contact Watson Industries to obtain a Returned Material Authorization number (RMA). Return Address & Contact Information Watson Industries, Inc Melby Street Eau Claire, WI ATTN: Service Department Telephone: (715) Fax: (715) support@watson-gyro.com Returning the Product Product shall be packaged making sure there is adequate packing around all sides. Please write the words, FRAGILE, DELICATE INSTRUMENT in several places on the outside of the shipping container. Correspondence shall include: Customer s Name and Address Contact Information Equipment Model Number Equipment Serial Number Description of Fault It is the customer s responsibility to pay all shipping charges from customer to Watson Industries, including import and transportation charges. 12
13 Appendix A The following outputs are available via the RS-232 serial link. Their full-scale ranges are listed for both decimal and binary format. Inertial Output Label Full Scale Decimal Full Scale Binary Time Since Reset TM Bank BK ±179.9º ±180º Elevation EL ±89.9º ±180º X Acceleration XA ±9.99 g ±10 g Y Acceleration YA ±9.99 g ±10 g Z Acceleration ZA ±9.99 g ±10 g X Angular Rate XR ±99.9 º/s ±200 º/s Y Angular Rate YR ±99.9 º/s ±200 º/s Bank Pendulum (simulated) XI ±179.9º ±180º Elevation Pendulum (simulated) YI ±89.9º ±180º Temperature TP -40º to 88ºC -40º to 88ºC (7 bit) Status Bits ST 1 byte 1 byte Flag Bits FL 1 byte 1 byte The Flag Bits contains the following information: a) Bits 0-2 show the current system time constant, using the following equations: TC=2 (Flag Value + 1) b) Bit 3 - If set, reference command selected. c) Bit 4 - If set, Steady Turn Mode Selected d) Bit 5 - If set, Coast mode is selected. e) Bit 6 - If set, the analog switches are disabled. Determining and Setting Output Channels To determine which channels are present. Hook the unit up to your computers serial port. Use hyperterminal program to interface with unit. Turn on unit. Wait for the startup message to appear on display. Hit the space bar twice within the first 5 seconds of turn on. Sometimes it takes a few tries to get the hang of this. Wait for the data string to start transmitting. Now the unit will take in the keyboard commands. To determine which channel present, first type '&' This will bring up the menu: TYPE IN THE NUMBER OF YOUR SELECTION (OR 'Q' TO QUIT): 1 = ADJUST TIME CONSTANTS 2 = SET OUTPUT CHANNELS 3 = LIST CURRENT OUTPUT CHANNEL SELECTION 4 = SET NEW BAUD RATE typing in '3' will show which channels are currently active. To change which channels are output type '&'(this will bring up the menu again) 13
14 Now type '2' to set up channels The following message will appear: TO SET FOR OUTPUT FOR ANY OF THE FOLLOWING DATA ITEMS, PRESS Y TO AVOID ANY OF THE FOLLOWING DATA ITEMS, PRESS N TO QUIT AND DISREGARD ANY OTHER DATA, PRESS Q *** DO YOU WANT TO PROCEED? (Y/N/Q) To proceed type 'Y' Now each channel will come up one at a time For example: DO YOU WANT OUTPUT TIME SINCE RESET? Type 'Y' to output channel, type 'N' to remove channel When you get to bottom of list, this message will appear: Y = GOBACK, N = INSTALL DATA & QUIT, Q = QUIT DO YOU WANT TO TRY TO SET DATA AGAIN? To accept channels type 'N', then hit space bar output data to resume. To make this channel selection the default the next time you power the unit on type in'"' (double quote) Setting Output Format There are two output formats. Decimal output - _ Command Binary output ^ Command To change the output format: Hook the unit up to your computers serial port. Use hyperterminal program to interface with unit. Turn on unit. Wait for the startup message to appear on display. Hit the space bar twice within the first 5 seconds of turn on. Sometimes it takes a few tries to get the hang of this. Wait for the data string to start transmitting. Now the unit will take in the keyboard commands. Press the key Command corresponding to the format you want to switch into. (for example type _ to change into Decimal Format.) To make this format selection the default the next time you power the unit on type in'"' (double quote.) 14
15 Appendix B MSB Data Word LSB As the data words are received, the LSB is shifted left to shift out the sign bit. The MSB is then connected to the LSB as a 16 bit word. This word is then shifted left to shift out the sign bit. What remains is a signed fractional word with a resolution of 13 bits plus a sign bit. DATA STREAM Carriage Return WORD 1 WORD 2 WORD 3 WORD 4... WORD N 0x0D All of the data words have a high sign bit, but the delimiter byte is an ASCII carriage return character that has a low sign bit. The nominal interface settings are: Byte 9600 Baud 8 Bit Data 1 Start Bit 1 Stop Bit No Parity 15
STRAPDOWN HEADING REFERENCE OWNER'S MANUAL
STRAPDOWN HEADING REFERENCE OWNER'S MANUAL PART NUMBER: SHR-360 WATSON INDUSTRIES, INC. 3035 MELBY STREET EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715) 839-8248 email: support@watson-gyro.com 1
More informationINERTIAL MEASUREMENT UNIT OWNER'S MANUAL
INERTIAL MEASUREMENT UNIT OWNER'S MANUAL PART NUMBER: IMU-E604 WATSON INDUSTRIES, INC. 3041 MELBY ROAD EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715) 839-8248 email: support@watson-gyro.com website:
More informationATTITUDE AND HEADING REFERENCE SYSTEM OWNER'S MANUAL
ATTITUDE AND HEADING REFERENCE SYSTEM OWNER'S MANUAL PART NUMBER: AHRS-E304 WATSON INDUSTRIES, INC. 3035 MELBY STREET EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715) 839-8248 email: support@watson-gyro.com
More informationINERTIAL MEASUREMENT UNIT OWNER'S MANUAL PART NUMBER: IMU-E604
, October 22, 2000 INERTIAL MEASUREMENT UNIT OWNER'S MANUAL PART NUMBER: IMU-E604 Revision G, October 21, 2000 WATSON INDUSTRIES, INC. 3041 MELBY ROAD EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715)
More informationECV ecompass Series. Technical Brief. Rev A. Page 1 of 8. Making Sense out of Motion
Technical Brief The ECV ecompass Series provides stable azimuth, pitch, and roll measurements in dynamic conditions. An enhanced version of our ECG Series, the ECV includes a full suite of precision, 3-axis,
More informationSDG1400 User s Guide
SDG1400 User s Guide Model SDG1400 Rate Sensor Systron Donner Inertial Sales and Customer Service Phone: +1 925.979. 4500 Fax: +1 925.349.1366 E-Mail: sales@systron.com www.systron.com SDG1400 User s Guide
More informationOPERATIONS MANUAL PCM-I/O48
OPERATIONS MANUAL PCM-I/O48 NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual
More informationInertial Measurement Unit (IMU) ISIS-IMU (Rev. C)
Inertial Measurement Unit (IMU) ISIS-IMU (Rev. C) Features Fully compensated Inertial Measurement Unit (IMU) DC in digital output Most cost effective IMU - Lowest cost 6 degree of freedom IMU in its performance
More informationResolver to Digital Expansion Board
Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................
More informationHybrid AC Driver [GCNC-1110]
Page 1 Installation Manual and Datasheet Page 2 Key Features Smooth and quiet operation at all speeds and extremely low motor heating Industrial grade performance for an alternating current servo motor
More informationApplications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment
TECHNICAL DATASHEET #TDA06020 CAN (SAE J1939) or (CANopen ) with Electronic Assistant P/N: A06020 Features: 1 or 2 axis inclination or slope sensors 2 axis (-80º 80º), functional up to +90 º 1 axis, vertically
More informationIntegrated Stepper Drive & Motor
SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More informationApplications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment
TECHNICAL DATASHEET #TDAX06025X Inclinometer CANopen, 2 5-pin M12 Connectors Features: 1 or 2 axis inclination or slope sensors 2 axis (-80º 80º), functional up to +90 º 1 axis, vertically positioned (-180º
More informationMTS-2000 USER S MANUAL
MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this
More informationModel CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual
Model CR103J DC Current and Voltage Calibrator/Standard ±0.01µA to ±111.1110mA ±0.1µV to ±11.11110V Operating Manual This page intentionally left blank. CR103J OPERATORS MANUAL Serial No. This page intentionally
More informationInstallation & Operation
LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon
More informationDCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies
DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR
More informationModel VT120 Fast Timing Preamplifier Operating and Service Manual
Model VT120 Fast Timing Preamplifier Operating and Service Manual Printed in U.S.A. ORTEC Part No. 740360 1202 Manual Revision C Advanced Measurement Technology, Inc. a/k/a/ ORTEC, a subsidiary of AMETEK,
More informationPRO 360. Owner's Manual
One-Year Limited Warranty If, within one year from the date of original purchase, the Pro 360 Digital Protractor fails to function because of defects in materials or workmanship, the manufacturer will,
More informationME15 Magnetic Encoder Manual Revision 1.1
Product Overview The ME15 Magnetic Encoder is the newest addition to AMCI s Encoder product line. The encoder is designed for lower resolution and lower cost applications and provides 10 bits of resolution.
More informationPowered Roller Controller for DeviceNet
PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered
More informationPCM-7140 Pulsed Current Source Operation Manual
PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031
More informationSMD Series Integrated Stepper Driver and Motor Revision 1.3
The AMCI Integrated Stepper Motor and Microstepping Drive Combination represents the future of Stepper Motor Control applications. The SMD is a self-contained stepper motor and driver package, capable
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationVP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display
VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature
More informationDIGITAL COMPASS SOLUTION
Features 5 Heading Accuracy, 0.5 Resolution 2-axis Capability Small Size (19mm x 19mm x 4.5mm), Light Weight Advanced Hard Iron Calibration Routine for Stray Fields and Ferrous Objects 0 to 70 C Operating
More informationPRO Owner's Manual
PRO 3600 Owner's Manual Feature Overview The Pro 3600 operates normally in a standard reference mode where level is displayed as 0.00. However, a new reference point for 0.00 can easily be established
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationTB-100 ControLynx Terminal Block
TB-100 ControLynx Terminal Block TECHNICAL MANUAL Version 1.3 September 2006 Copyright This technical manual and the equipment, firmware and software described herein are copyrighted by INTENT DIGITAL
More informationOPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR
1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com
More informationGlobal Water Instrumentation, Inc.
Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Display: EZ100 11/12/04-1 - Congratulations on your purchase of the EZ100 Display.
More informationSection 1 Introduction
Section 1 Introduction The AT90ICEPRO is a real time In-Circuit Emulator (ICE) for all AT90S1200, -S2313, -S2323, -S2333, -S2343, -S4414, -S4433, -S4434, -S8515 and -S8535 devices. It can be upgraded to
More informationKVH DSP-1750 Fiber Optic Gyro
KVH DSP-1750 Fiber Optic Gyro Dual Axis Standard Rate Digital Output Technical Manual DSP-1750 DSP-1750 Fiber Optic Gyro Technical Manual (Dual-Axis Version) This technical manual supports KVH Industries
More informationEco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features
Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease
More informationES-600 Ozone Controller Operation Manual
ES-600 Ozone Controller Operation Manual Questions about your product? Find answers here: Web: www.ozonesolutions.com/es-600 Phone: 712-439-6880 Ozone Solutions OZONE CONTROLLER Model ES-600 Instructions
More information8520/8520R. User Manual
/R User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Disclaimer SuperLogics
More informationDCM Digital Control Modules
DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.
More informationThis Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.
This Datasheet for the IC660BBA026 Block 24/48Vdc Analog Current Source 6 Inputs http://www.cimtecautomation.com/parts/p-14421-ic660bba026.aspx Provides the wiring diagrams and installation guidelines
More informationLNX Series Motor and Drives
LNX Series Motor and Drives Operator's Manual PN 04-01808 x PRECISION MOTION CONTROLS 2530 Berryessa Rd. #209 San Jose, CA 95132 1 2 Table of Contents Page Introduction 1. Description 3 2. Warranty 4 Installation
More informationA2T. Absolute Optical Inclinometer Page 1 of 5. Description. Mechanical Drawing. Features
Description Page 1 of 5 The A2T is a single axis, digital gravity angle sensor. The A2T serves as a full 360 range absolute tilt sensing programmable level with either digital or analog output. Internally,
More informationV ARIENSE SENSE Y O UR W ORLD. Inertial Measurement Unit VMU931. User Guide. Version 1.3. March VARIENSE INC.
V ARIENSE SENSE Y O UR W ORLD Inertial Measurement Unit VMU931 Version 1.3 March 2018 2017 VARIENSE INC. Contents 1 Product Overview 1 2 Safety 2 3 Setup 3 3.1 Mounting the sensor...........................................
More informationVIP-812A DUAL NETWORKED STATION PORT
ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS
More informationPIM-Mini Pulsed Current Source Operation Manual
PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007
More informationUser's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction
User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt
More informationOPERATIONS MANUAL PCM-DOC
OPERATIONS MANUAL PCM-DOC NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual
More informationCTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *
CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE Version 1.3 CTI Part #062-00305-013 *062-00305-011* 2551-AIOG 110106 $25 Copyright 2006 Control Technology Inc.
More informationINTEGRATED TECH FOR INDUSTRIAL POSITIONING
INTEGRATED TECH FOR INDUSTRIAL POSITIONING Integrated Tech for Industrial Positioning aerospace.honeywell.com 1 Introduction We are the world leader in precision IMU technology and have built the majority
More informationAnalog Interface Unit Operation Manual
Analog Interface Analog Interface Unit Operation Manual WARRANTY Accurate Technology, Inc. warrants the product against defective parts and workmanship for 1 year commencing from the date of original purchase.
More informationTECHNICAL MANUAL PRESSURE TRANSDUCER TYPE MLP
RDP CUSTOMER DOCUMENT TECHNICAL MANUAL PRESSURE TRANSDUCER TYPE MLP Doc. Ref CD1001Q BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense Inc. 2216
More informationDigital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03
Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The
More informationSTATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL
STATIC METERS Models 211 & 212 SURVEYORSTAT Models 211XL & 212XL Operating Manual 5/09 1.0 GENERAL DESCRIPTION The Model 211 and 212 Static Meters, shown in Figures 1.0-1a and b, are accurate, compact
More informationEco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features
Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease
More informationDATASHEET SQ-SI-360DA-VMP SOLID-STATE MEMS INCLINOMETER ±70 º DUAL AXIS, 360 º SINGLE AXIS, SERIAL AND ANALOG OUTPUT FUNCTIONAL DIAGRAMS
Output Voltage (volts) DATASHEET FUNCTIONAL DIAGRAMS -HMP -VMP FUNCTION ± 70 º dual axis angle measurement 360 º single axis angle measurement UART serial output and analog output APPLICATIONS Platform
More informationSGJ Cable Actuated Sensor Industrial CANBus J1939
Cable Actuated Sensor Industrial CANBus J939 Two Available Stroke Ranges: 0-80 in & 0-20 in. Rugged Polycarbonate Enclosure Simple Installation Compact Design Built for IP67 environments IN STOCK FOR QUICK
More informationSonic Ruptor 400. User Manual
Sonic Ruptor 400 User Manual Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and
More informationI/O SIGNAL CONDITIONER
Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT
More informationOPERATING MANUAL AND TECHNICAL REFERENCE
MODEL WFG-D-130 HIGH SPEED DIGITAL 3 AXIS FLUXGATE MAGNETOMETER OPERATING MANUAL AND TECHNICAL REFERENCE December, 2012 Table of Contents I. Description of the System 1 II. System Specifications.. 2 III.
More informationUser s Guide. POWERVAR Single Phase Power Conditioners
POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant
More informationApplications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment
Features: 1 or 2 axis inclination or slope sensors 2 axis (-80º 80º), functional up to +90 º 1 axis, vertically positioned (-180º 180º or 0 360º) High resolution and accuracy SAE J1939 (CANopen models
More informationIt s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1
Installation and Operation Guide 70-210043-17 V 1.1 Copyright 2008 Remote Technologies Incorporated All rights reserved. 2 DECLARATIONS 117 612 914 DECLARATION OF CONFORMITY (DOC) The Declaration of Conformity
More informationThis Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs
This Datasheet for the IC660BBA104 Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs http://www.qualitrol.com/shop/p-14425-ic660bba104.aspx Provides the wiring diagrams and installation guidelines
More informationA2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features
Description Page 1 of 7 The A2K optical encoder is a 12 bit absolute rotary kit style encoder which reports a shaft angle within a single 360 degree rotation of a shaft. The kit style A2K allows the encoder
More informationDC425 NEMA 4X Analog Output Transducers
User User Manual Manual DC425 NEMA 4X Analog Output Transducers ADV ANC ED MIC RO CON T RO L S INC. Manual #: 940-0D030 DC425 Description Offering a 4-20 ma output over single or multiple turns, the DC425
More informationIsolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage
More informationHEAVY DUTY INCLINOMETER ANALOG & RS232 INTERFACE
The Heavy Duty inclinometers are robust inclination sensors specially designed for applications involving rough handling and exposure to rigorous conditions. The die cast aluminium housing and the metal
More informationMODBUS MANUAL For the AccUView UV Transmission Monitor
MODBUS MANUAL For the AccUView UV Transmission Monitor HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 E-Mail: info@hfscientific.com Website: www.hfscientific.com
More informationAWP-24-3 Wave Height Gauge User's Guide
AWP-24-3 Wave Height Gauge User's Guide Issue: 1.5 Status: Released 18-Dec-2014 Prepared by Akamina Technologies Inc. Akamina Technologies Inc. 91 Norice St.,Ottawa,Ontario K2G 2X9, CANADA TEL: +1 613
More informationOZONE SWITCH Model OS-6. OS-6 Features
USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.
More informationPMDX-170 Slotted Optical Sensor
PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc
More informationPC 150. Digital Bench Scale. Operation Manual
PC 150 Digital Bench Scale Operation Manual Revision 1.2 September 14, 2000 1996-2000 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 35 Waltz Drive Wheeling,
More informationV-9908 MESSAGE/PAGE PANEL
Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides
More informationSierra 80 Volt Brushless DC Motor Controller Product Specification
Sierra 80 Volt Brushless DC Motor Controller Product Specification Assembly 025F0135 600A0588 Rev. B January 29, 2010 025F0135 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description
More informationKBMG MULTI-SPEED BOARD
TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this
More informationINDUSTRIAL INCLINOMETER ANALOG & RS232 INTERFACE
The industrial inclinometers are compact solutions for determining the inclination in both single and dual axes with remarkable precision and at a lower expense. The molded housing provides the mechanical
More informationPMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B
PMDX-103 Parallel Port Isolator Board User s Manual Date: 20 February 2007 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977
More informationIsolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage
More informationVE8014A/VE8014AR QUAD NETWORKED STATION PORT
ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.
More informationVIP-804 QUAD ENHANCED NETWORK AUDIO PORT
ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to
More informationDATASHEET SQ-SI-360DA-VMP SOLID-STATE MEMS INCLINOMETER ±70 º DUAL AXIS, 360 º SINGLE AXIS, SERIAL AND ANALOG OUTPUT. -Az RANGE AND SCALE
Gravity -Az -Ax +A θ φ -HMP -VMP DESCRIPTION The inclinometer module performs calibrated angle measurement with analog voltage and digital serial outputs. FUNCTION ± 70 º dual axis angle measurement 360
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationPB-501. Logic Design Trainer Instruction Manual
PB-501 Logic Design Trainer Instruction Manual 10/2009 2 All rights reserved. No Part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical,
More informationIsolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Process Current Output 7B39 FEATURES Interfaces, isolates and filters a 0 V to + 10 V or +1 V to +5 V input signal. Provides an isolated process current output of 0 ma to 20 ma or 4 ma to 20
More informationApplication basics/handbook
Application basics/handbook Inclination sensor / Tiltmeter GKAS2000 series with Modbus output a Dear Customer, thank you for purchasing this product. These Instruments are a results of a cooperation between
More informationSIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS
SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL
More informationIsolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.
More informationMODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL
10623 Roselle Street, San Diego, CA 92121 (858) 550-9559 FAX (858) 550-7322 contactus@accesio.com www.accesio.com MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL FILE: MUSB-DA12-8E.B1h
More informationIMU06WP. What is the IMU06?
IMU06 What is the IMU06? The IMU06 is a compact 6 degree of freedom inertial measurement unit. It provides 3 axis acceleration (maximum 10G) and angular velocities (maximum 300 degrees/s) on both CAN and
More informationCTI 2550 EIGHT CHANNEL ISOLATED ANALOG INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 2.0 CTI Part # IOG $25
CTI 2550 EIGHT CHANNEL ISOLATED ANALOG INPUT MODULE INSTALLATION AND OPERATION GUIDE Version 2.0 CTI Part #062-00102 2452IOG 092205 $25 ii CTI 2550 Installation and Operation Guide Copyright 2005 Control
More informationKramer Electronics, Ltd. USER MANUAL
Kramer Electronics, Ltd. USER MANUAL Models: VP-200NK, 1:2 High Resolution XGA DA VP-300NK, 1:3 High Resolution XGA DA VP-400NK, 1:4 High Resolution XGA DA Contents Contents 1 Introduction 1 2 Getting
More informationGlobal Water globalw.com. Global Water. Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com PC300: Process Controller
More informationCK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2
CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering
More informationIsolated Process Current Input with Loop Power 7B35
Isolated Process Current Input with Loop Power 7B35 FEATURES Single-channel signal conditioning current input module that interfaces with two-wire transmitters. Module provides a precision output of either
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationDeviceNet Expansion Board
DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................
More informationModel E100RC. DC Millivolt Reference Source ±1µV to ±10Vdc - 10ppm Resolution. Operating Manual
Model E100RC DC Millivolt Reference Source ±1µV to ±10Vdc - 10ppm Resolution Operating Manual This page intentionally left blank. MANUALLY OPERATED DC VOLTAGE CALIBRATOR Model E-100-RC Serial No. This
More informationKramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver
Kramer Electronics, Ltd. USER MANUAL Model: WP-210E XGA Line Driver Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 1 4 Your WP-210E XGA Line Driver 2 4.1 Your WP-210E: Available in 3
More informationKVH DSP-1500 Fiber Optic Gyro. Dual-Axis Version. Technical Manual DSP-1500
KVH DSP-1500 Fiber Optic Gyro Dual-Axis Version Technical Manual DSP-1500 DSP-1500 Fiber Optic Gyro Technical Manual (Dual-Axis Version) This technical manual supports KVH Industries DSP-1500 dual-axis
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationLN3X Series Motor and Drives
LN3X Series Motor and Drives Operator's Manual PN 04-01920 C PRECISION MOTION CONTROLS 2175 De La Cruz Blvd., #1 Santa Clara, CA 95050 1 Contents INTRODUCTION... 3 Description... 3 Features... 3 Warranty...
More information