MasterINTERFACE 39 Series - Relay interface modules

Size: px
Start display at page:

Download "MasterINTERFACE 39 Series - Relay interface modules"

Transcription

1 MasterINTERFACE 39 Series - Relay interface modules 39 SERIES Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross) terminals and s versions 35 mm rail mounting (EN 60715) MasterASIC For general use in any type of system EMR: 6 to 24 and 125 AC/DC, 230 AC supply SSR: 6 to 24 DC, 125 AC/DC, 230 AC supply and EMR Electromechanical Relays 1 CO 6 A 250 AC High switching capability SSR Solid State Relays 1 solid state output (options 0.1 A 48 DC, 2 A 24 DC, 2 A 240 AC) Silent, high speed switching, long electrical life 39.11/ /39.00 MasterPLUS Accepts the output fuse module, for the easy and space efficient protection of output circuits EMR: 6 to 125 AC/DC, 125 and 220 DC, 230 AC supply SSR: AC/DC, 6 to 220 DC and 230 AC supply Special 125 AC/DC and 230 AC leakage current suppression types ( , EMR and , SSR) and MasterINPUT Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices Page 4 Page / / Page 6 Page / /39.70 EMR: 6 to 24 and 125 AC/DC, 230 AC supply SSR: 6-24 DC, AC/DC, 230 AC supply and MasterOUTPUT Jumper link option for the quick and easy distribution of supply voltage to output side and its connection to electromagnetic valves and similar output devices EMR: 6 to 24 and 125 AC/DC, 230 AC supply SSR: 6 to 24 DC, 125 AC/DC, 230 AC supply and MasterTIMER Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions Output with fuse module option EMR and SSR: 12 to 24 AC/DC supply and Page 8 Page / /39.50 Page 10 Page / /39.90 Page 12 Page 13

2 39 SERIE S MasterASIC For general interface use in any type of system and application. Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs or motors. Or for output interface between PLC s controllers and relays, solenoids etc. Typical Applications MasterPLUS This special version provides extra protection for the output circuit thanks to the replaceable fuse module. For general interface use in any type of system and application. Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs or motors. Or for output interface between PLC s controllers and relays, solenoids etc. Output devices Output devices Fuse module PLC - Output PLC - Output PLC - Input PLC - Input Fuse module Input devices Input devices

3 MasterINPUT These models allow the full termination of input device to the interface without the need for additional terminals - saving component cost, time and panel space. Quick and easy distribution of supply voltage through the jumper link on the us-ar () connection. Ideal for interface applications between the auxiliary contacts, sensors, limit switches and Controllers or PLC s. Typical Applications MasterOUTPUT These models allow the full termination of output device to the interface without the need for additional terminals - saving component cost, time and panel space. Quick and easy distribution of supply voltage through the jumper link on the us-ar () connection. Ideal for interface applications between the PLC s or Controllers and output devices such as electomagnetic valves or motors etc.. MasterTIMER Slim and Multifunction Timed Interface modules. 39 SERIES Output devices Output devices Fuse module PLC - Output PLC - Output PLC - Input PLC - Input Input devices Input devices 3

4 39 SERIE S 39 Series - Relay interface modules A MasterASIC - EMR Features 39.11/ Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems Common connection possible with optional jumper links (terminals A1, A2 and 11) UL Listing (certain relay/socket combinations) 6 A electromechanical relay 6 to 24 and 125 AC/DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting For outline drawing see page 20, 21 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage AC Rated load AC1 A Rated load AC15 (230 AC) A Single phase motor rating (230 AC) kw reaking capacity DC1: 30/110/220 A Minimum switching load mw (/ma) Standard contact material Supply specification Nominal voltage (U N ) AC/DC AC (50/60 Hz) Rated power A (50 Hz)/W Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) k Dielectric strength between open contacts AC Ambient temperature range C Protection category Approvals relay (according to type) 4 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi See page 16 ( )U N 0.6 U N 0.1 U N ( )U N /6 6 (8 mm) 1, IP 20

5 39 Series - Relay interface modules A 39 SERIES MasterASIC - SSR Features 39.10/ Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems Common connection possible with optional jumper links (terminals A1, A2 and 13+) UL Listing (certain relay/socket combinations) 0.1 or 2 A solid state relay 6 to 24 DC, 125 AC/DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting For outline drawing see page 20, 21 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) A Rated voltage/maximum blocking voltage Switching voltage range Repetitive peak off-state voltage pk Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop Supply specification Nominal voltage (U N ) AC/DC AC (50/60 Hz) DC Rated power A (50 Hz)/W Must drop-out voltage Technical data Operate/release time ms Dielectric strength between input/output AC Ambient temperature range C Protection category Approvals relay (according to type) 39.x0.x.xxx x0.x.xxx x0.x.xxx NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/ AC (1.5 24) DC (1.5 48) DC (12 275) AC See page 17 ( ) U N 0.1 U N 0.2/ / /12 2, IP20 5

6 39 SERIE S 39 Series - Relay interface modules A MasterPLUS - EMR Features 39.31/ / Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Accepts output fuse module (for 5 x 20 mm fuses) for quick and easy load protection, see page 24 Common connection possible with optional jumper links (terminals A1, A2 and 11) UL Listing (certain relay/socket combinations) 6 A electromechanical relay 6 to 125 AC/DC, 125 and 220 DC, 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting 6 A electromechanical relay Leakage current suppression version, 125 AC/DC and 230 AC supply and push-in terminal / / Fuse module For outline drawing see page 20, 21 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage AC Rated load AC1 A Rated load AC15 (230 AC) A Single phase motor rating (230 AC) kw reaking capacity DC1: 30/110/220 A Minimum switching load mw (/ma) Standard contact material Supply specification Nominal voltage (U N ) AC/DC AC (50/60 Hz) DC Rated power A (50 Hz)/W Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) k Dielectric strength between open contacts AC Ambient temperature range C Protection category Approvals relay (according to type) 6 1 CO (SPDT) 1 CO (SPDT) 6/10 6/10 250/ /400 1,500 1, /0.2/0.12 6/0.2/ (12/10) 500 (12/10) AgNi AgNi See page 16 See page 16 ( ) U N ( ) U N 0.6 U N 0.6 U N 0.1 U N 0.3 U N /6 5/6 6 (8 mm) 6 (8 mm) 1,000 1, (+55 for 220 DC) IP20 IP20

7 39 Series - Relay interface modules A 39 SERIES MasterPLUS - SSR Features 39.30/ / Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Accepts output fuse module (for 5 x 20 mm fuses) for quick and easy load protection, see page 24 Common connection possible with optional jumper links (terminals A1, A2 and 13+) UL Listing (certain relay/socket combinations) 0.1 or 2 A solid state relay AC/DC, 6 to 220 DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting 0.1 or 2 A solid state relay Leakage current suppression version, 125 AC/DC and 230 AC supply and push-in terminal / / Fuse module For outline drawing see page 20, 21 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) Rated voltage/maximum blocking voltage Switching voltage range Repetitive peak off-state voltage Minimum switching current Max. OFF-state leakage current Max. ON-state voltage drop Supply specification Nominal voltage (U N ) Rated power Must drop-out voltage Technical data Operate/release time Dielectric strength between input/output Ambient temperature range Protection category Approvals relay (according to type) A pk ma ma AC/DC AC (50/60 Hz) DC A (50 Hz)/W ms AC C 39.x0.x.xxx x0.x.xxx x0.x.xxx x0.3.xxx x0.3.xxx x0.3.xxx NO (SPST-NO) 1 NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/ AC 24/33 DC 48/60 DC 240/ AC (1.5 24) DC (1.5 48)DC (12 275) AC (1.5 24) DC (1.5 48)DC (12 275) AC See page 17 See page 17 ( ) U N ( ) U N 0.1 U N 0.3 U N 0.2/ / /12 0.2/ / /12 2,500 2, IP20 IP20 7

8 39 SERIE S 39 Series - Relay interface modules A MasterINPUT - EMR Features 1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (us-bar connection ) Gold plated output contact as standard, for better compatibility with low energy PLC inputs UL Listing (certain relay/socket combinations) 39.41/ A electromechanical relay AC/DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting For outline drawing see page 20, 21 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage AC Rated load AC1 A Rated load AC15 (230 AC) A Single phase motor rating (230 AC) kw reaking capacity DC1: 30/110/220 A Minimum switching load mw (/ma) Standard contact material Supply specification Nominal voltage (U N ) AC/DC AC (50/60 Hz) Rated power A (50 Hz)/W Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) k Dielectric strength between open contacts AC Ambient temperature range C Protection category Approvals relay (according to type) CO (SPDT) 6/10 250/400 1, /0.2/ (5/2) AgNi + Au See page 16 ( ) U N 0.6 U N 0.1 U N /6 6 (8 mm) 1, IP20

9 39 Series - Relay interface modules A 39 SERIES MasterINPUT - SSR Features 39.40/ Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (us-bar connection ) UL Listing (certain relay/socket combinations) 0.1 or 2 A solid state relay DC, AC/DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting For outline drawing see page 20, 21 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) Rated voltage/maximum blocking voltage Switching voltage range Repetitive peak off-state voltage Minimum switching current Max. OFF-state leakage current Max. ON-state voltage drop Supply specification A pk ma ma 39.x0.x.xxx x0.x.xxx x0.x.xxx NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/ AC (1.5 24) DC (1.5 48) DC (12 275) AC Nominal voltage (U N ) Rated power AC/DC AC (50/60 Hz) DC A (50 Hz)/W See page 17 ( ) U N Must drop-out voltage 0.1 U N Technical data Operate/release time Dielectric strength between input/output Ambient temperature range Protection category Approvals relay (according to type) ms AC C 0.2/ / /12 2, IP20 9

10 39 SERIE S 39 Series - Relay interface modules A MasterOUTPUT - EMR Features 39.21/ Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to output side (us-bar connection ) and its connection to electromagnetic valves and similar output devices UL Listing (certain relay/socket combinations) 6 A electromechanical relay AC/DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting For outline drawing see page 20, 21 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage AC Rated load AC1 A Rated load AC15 (230 AC) A Single phase motor rating (230 AC) kw reaking capacity DC1: 30/110/220 A Minimum switching load mw (/ma) Standard contact material Supply specification Nominal voltage (U N ) AC/DC AC (50/60 Hz) Rated power A (50 Hz)/W Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) k Dielectric strength between open contacts AC Ambient temperature range C Protection category Approvals relay (according to type) NO (SPST-NO) 6/10 250/400 1, /0.2/ (12/10) AgNi See page 16 ( ) U N 0.6 U N 0.1 U N /6 6 (8 mm) 1, IP20

11 39 Series - Relay interface modules A 39 SERIES MasterOUTPUT - SSR 39.20/39.50 Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to output side (us-bar connection ) and its connection to electromagnetic valves and similar output devices UL Listing (certain relay/socket combinations) 0.1 or 2 A solid state relay 6 to 24 DC, 125 AC/DC and 230 AC supply and push-in terminal 35 mm rail (EN 60715) mounting For outline drawing see page 20, 21 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) Rated voltage/maximum blocking voltage Switching voltage range Repetitive peak off-state voltage Minimum switching current Max. OFF-state leakage current Max. ON-state voltage drop Supply specification A pk ma ma 39.x0.x.xxx x0.x.xxx x0.x.xxx NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/ AC (1.5 24) DC (1.5 48) DC (12 275) AC Nominal voltage (U N ) Rated power Must drop-out voltage Technical data AC/DC AC (50/60 Hz) DC A (50 Hz)/W See page 17 ( ) U N 0.1 U N Operate/release time Dielectric strength between input/output Ambient temperature range Protection category Approvals relay (according to type) ms AC C 0.2/ / /12 2, IP20 11

12 39 SERIE S 39 Series - Relay interface modules A MasterTIMER - EMR Features 39.81/39.91 Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels Timer adjustment via top mounted rotary knob, accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions Accepts output fuse module (for 5 x 20 mm fuses) for quick and easy load protection, see page 24 Common connection possible with optional jumper links (terminals A1, A2 and 15) UL Listing (certain relay/socket combinations) A electromechanical relay AC/DC supply and push-in terminal 35 mm rail (EN 60715) mounting Fuse module AI: On-delay DI: Interval GI: Pulse (0.5 s) delayed SW: Symmetrical flasher (starting pulse on) E: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off For outline drawing see page 20, 21 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage AC Rated load AC1 A Rated load AC15 (230 AC) A Single phase motor rating (230 AC) kw reaking capacity DC1: 30/110/220 A Minimum switching load mw (/ma) Standard contact material Supply specification Nominal voltage (U N ) AC/DC Rated power AC/DC A (50 Hz)/W Holding voltage Must drop-out voltage Technical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy full range % Electrical life at rated load AC1 cycles Ambient temperature range C Protection category Approvals relay (according to type) 12 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi See page 16 ( ) U N 0.6 U N 0.1 U N ( )s, (3...60)s, (1...20)min, ( )h ± IP20

13 39 Series - Relay interface modules A 39 SERIES MasterTIMER - SSR Features 39.80/39.90 Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels Timer adjustment via top mounted rotary knob; accessible after assembly Start terminal DIP-switch for selection of 4 time scales and 8 functions Accepts output fuse module (for 5 x 20 mm fuses) for quick and easy load protection, see page 24 Common connection possible with optional jumper links (terminals A1, A2 and 15+) UL Listing (certain relay/socket combinations) or 2 A solid state relay AC/DC supply and push-in terminal 35 mm rail (EN 60715) mounting Fuse module AI: On-delay DI: Interval GI: Pulse (0.5 s) delayed SW: Symmetrical flasher (starting pulse on) E: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off For outline drawing see page 20, 21 Output specification (SSR) 39.x0.x.xxx x0.x.xxx x0.x.xxx.8240 Contact configuration 1 NO (SPST-NO) Rated current/maximum peak current (10 ms) A 2/20 DC 0.1/0.5 DC 2/40 AC Rated voltage/maximum blocking voltage 24/33 DC 48/60 DC 240/ AC Switching voltage range (1.5 24) DC (1.5 48) DC (12 275) AC Repetitive peak off-state voltage pk 600 Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop Supply specification Nominal voltage (U N ) AC/DC Rated power A (50 Hz)/W See page 17 ( ) U N Holding voltage 0.6 U N Must drop-out voltage 0.1 U N Technical data Specified time range ( )s, (3...60)s, (1...20)min, ( )h Repeatability % ± 1 Recovery time ms 50 Minimum control impulse ms 50 Setting accuracy full range % 5 Ambient temperature range Protection category Approvals relay (according to type) C IP20 13

14 39 SERIE S 39 Series - Relay interface modules - Ordering information Ordering information Example: MasterPLUS 39 series screw terminal interface module, electromechanical relay output, 1 CO (SPDT), 24 AC/DC coil. A C D Series Type 1 = MasterASIC, screw terminal 0 = MasterASIC, push-in terminal 3 = MasterPLUS, screw terminal, fuse-protectable output 6 = MasterPLUS, push-in terminal, fuse-protectable output 4 = MasterINPUT, screw terminal 7 = MasterINPUT, push-in terminal 2 = MasterOUTPUT, screw terminal 5 = MasterOUTPUT, push-in terminal 8 = MasterTIMER multifunction, screw terminal, fuse-protectable output 9 = MasterTIMER multifunction, push-in terminal, fuse-protectable output No. of poles 1 = 1 CO (only EMR, except 39.21/51, 1 NO) 0 = 1 NO (only SSR) Coil version, EMR / Input version, SSR 0 = AC (50/60 Hz)/DC 3 = Leakage current suppression AC (50/60 Hz) 7 = DC sensitive 8 = AC (50/60 Hz) Coil voltage, EMR / Input voltage, SSR See page 16 D: Special ersion, EMR 0 = Standard C: Options, EMR 6 = Standard : Contact circuit, EMR 0 = CO (except 39.21/51, 1 NO) A: Contact material, EMR 0 = AgNi Standard 4 = AgSnO 2 5 = AgNi + Au ACD: Output version, SSR 7048 = 0.1 A - 48 DC 8240 = 2 A AC 9024 = 2 A - 24 DC EMR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A C D 39.11/ / / / / SSR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Input version Output version, ACD / / / / /

15 Technical data Insulation according to EN Nominal voltage of supply system AC 230/400 Rated insulation voltage AC Pollution degree 3 2 Insulation between coil and contact set Type of Insulation Overvoltage category Rated impulse voltage k (1.2/50) μs 6 Reinforced Dielectric strength AC 4,000 Insulation between open contacts (EMR) Type of disconnection III Micro-disconnection Dielectric strength AC/k (1.2/50) μs 1,000/1.5 Conducted disturbance immunity U N 60 U N = 125 U N = 230 Fast transients (burst 5/50 ns, 5 khz) according to EN at supply terminals k oltage pulses (surge 1.2/50 μs) according to EN at supply terminals (differential mode) k Other data ounce time (EMR) : NO/NC ms 1/6 ibration resistance (EMR, Hz): NO/NC g 10/15 Power lost to the environment without contact current W 0.2 (24 ) 0.4 (230 ) with rated current W 0.6 (24 ) 0.9 (230 ) Terminals 39 Series - Relay interface modules - Technical data Wire strip length mm 10 8 Screw torque Nm 0.5 Solid and stranded cable Max. wire size mm 2 1 x 2.5/2 x x 2.5 AWG 1 x 14/2 x 16 1 x 14 Min. wire size mm 2 1 x x 0.2 AWG 1 x 24 1 x 24 Solid and stranded cable 39 SERIES Contact specification (EMR) F 39 - Electrical life (AC) v contact current H 39 - Maximum DC1 breaking capacity Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 DC breaking current (A) DC voltage () When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of can be expected. In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. 15

16 39 SERIE S 39 Series - Relay interface modules - Technical data Coil specifications - Electromechnical Relay Coil data DC, type 39.31/61 Nominal oltage Coil code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma W 125 ( ) Coil data AC/DC, type 39.11/21/31/41/01/51/61/71 Nominal oltage Coil code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma A/W / / / (1) /0.35 (1) 60 AC/DC for type 39.31/61 only 125 ( ) /0.7 Coil data AC, type 39.11/21/31/41/01/51/61/71 Nominal oltage Coil code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma A/W 230 ( ) /0.4 Coil data leakage current suppression versions, type /61.3 Nominal oltage Coil code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma A/W 125 ( ) /1 The 39 Series interface modules (supply version 3) have builtin leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at ( ) AC/DC and ( ) AC. This problem can occur, for example, when connecting the interface modules to PLC s with triac outputs or when connecting via relatively long cables. 230 ( ) /0.5 Coil data AC/DC timer, type 39.81/91 Nominal oltage Coil code (AC/DC) Must drop-out voltage Rated input current at U N Rated power at U N U N U min U max U r DC AC DC AC ma ma W A/W / /0.3 16

17 39 Series - Relay interface modules - Technical data 39 SERIES Input specifications - Solid State Relay Input data DC, type 39.10/20/30/40/00/50/60/70 Nominal oltage Input code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma W (1) (1) 60 DC, 125 DC and 220 DC for type 39.30/60 only 125 (1) ( ) (1) Input data AC/DC, type 39.10/20/30/40/00/50/60/70 Nominal oltage Input code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma A/W 24 (2) / ( ) /0.7 (2) 24 AC/DC for type 39.30/40/60/70 only Input data AC, type 39.10/20/30/40/00/50/60/70 Nominal oltage Input code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma A/W 230 ( ) /0.4 Input data leakage current suppression versions, type /60.3 Nominal oltage Input code Must drop-out voltage Rated input current at U N Rated power U N U min U max U r I N at U N ma A/W 125 ( ) /1 The 39 Series interface modules (supply version 3) have builtin leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at ( ) AC/DC and ( ) AC. This problem can occur, for example, when connecting the interface modules to PLC s with triac outputs or when - connecting via relatively long cables. 230 ( ) /0.5 Input data AC/DC timer, type 39.80/90 Nominal oltage Input code (AC/DC) Must drop-out voltage Rated input current at U N Rated power at U N U N U min U max U r DC AC DC AC ma ma W A/W / /0.3 17

18 39 SERIE S 39 Series - Timed interface modules Timer specifications EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN k air discharge EN k Radio-frequency electromagnetic field (80 1,000 MHz) EN /m (1,400 2,700 MHz) EN /m Fast transients (burst) (5-50 ns, 5 and 100 khz) on Supply terminals EN k on control signal terminals EN k Surges (1.2/50 μs) on supply and control common mode EN k signal terminals differential mode EN k Radio-frequency common mode on Supply terminals EN ( MHz) on control signal terminals EN Radiated and conducted emission EN class Other data ounce time (EMR) : NO/NC ms 1/6 ibration resistance (EMR, Hz): NO/NC g 10/15 Power lost to the environment without contact current W 0.3 with rated current W 0.8 Terminals Wire strip length mm 10 8 Screw torque Nm 0.5 Solid and stranded cable Max. wire size mm 2 1 x 2.5/2 x x 2.5 AWG 1 x 14/2 x 16 1 x 14 Min. wire size mm 2 1 x x 0.2 AWG 1 x 24 1 x 24 Solid and stranded cable Times scales ( )s (3...60)s (1...20)min ( )h Functions LED Supply voltage NO contact/output OFF Open ON Open ON Open (timing to close in progress) ON Closed 18

19 39 Series - Timed interface modules 39 SERIES Wiring diagram U = Supply voltage S = Signal switch = Output contact Without control signal (AI) On-delay Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed (DI) Interval Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset (GI) Pulse (0.5s) delayed Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s (SW) Symmetrical flasher (starting pulse on) Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). With control signal (E) Off-delay with control signal Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. * *With DC supply, positive polarity has to be conneted to 1, terminal (according to EN ) (CE) On- and off-delay with control signal Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Interval with control signal on Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset (EE) Interval with control signal off Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal 1. ** A voltage other than the supply voltage can be applied to the command Start (1), example: A1 - A2 = 24 AC 1 - A2 = 12 DC 19

20 39 SERIE S 39 Series - Relay interface modules A Outline drawings - sockets / / / /

21 39 Series - Relay interface modules A 39 SERIES Outline drawings - sockets / / / / Main features s The push-in terminals permit the quick connection of solid wires or ferrules by their simple insertion into the terminal (A). It is possible to open the terminal to extract the wire by first pushing down on the push-button using a screwdriver (C). For stranded cable it is necessary first to open the terminal using the push button, both for the extraction (C) and insertion (). It is possible at any time to check the connection via the test aperture, using a 2mm diameter test probe (D). A C D 21

22 39 SERIE S Example:.xxxx Series - Relay interface modules A Electromechanical Relay (1 Pole 6 A) & Screw Socket Combinations Interface Module Code Coil voltage Relay Socket MasterASIC AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC MasterPLUS AC/DC AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC ( ) DC DC ( ) AC/DC ( ) AC MasterINPUT AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC MasterOUTPUT 1 NO, 6 A only AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC MasterTIMER AC/DC AC/DC Solid State Relay (1 Pole 0.1 or 2 A) & Screw Socket Combinations Interface Module Code Input voltage Relay Socket MasterASIC xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterPLUS xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx 60 DC xxxx xxxx ( ) DC xxxx xxxx 220 DC xxxx xxxx 24 AC/DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterINPUT xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx 24 AC/DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterOUTPUT xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterTIMER xxxx 12 AC/DC xxxx xxxx 24 AC/DC xxxx

23 39 Series - Relay interface modules A 39 SERIES Electromechanical Relay (1 Pole 6 A) & Push-in Socket Combinations Interface Module Code Coil voltage Relay Socket MasterASIC AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC MasterPLUS AC/DC AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC ( ) DC DC ( ) AC/DC ( ) AC MasterINPUT AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC MasterOUTPUT 1 NO, 6 A only AC/DC AC/DC AC/DC ( ) AC/DC ( ) AC MasterTIMER AC/DC AC/DC Solid State Relay (1 Pole 0.1 or 2 A) & Push-in Socket Combinations Example:.xxxx Interface Module Code Input voltage Relay Socket MasterASIC xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterPLUS xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx 60 DC xxxx xxxx ( ) DC xxxx xxxx 220 DC xxxx xxxx 24 AC/DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterINPUT xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx 24 AC/DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterOUTPUT xxxx 6 DC xxxx xxxx 12 DC xxxx xxxx 24 DC xxxx xxxx ( ) AC/DC xxxx xxxx ( ) AC xxxx MasterTIMER xxxx 12 AC/DC xxxx xxxx 24 AC/DC xxxx

24 39 SERIE S 39 Series - Relay interface modules A Accessories Output fuse module for 39.31/30/81/80/61/60/91/90 types For 5 x 20 mm fuses up to 6 A, Easy visibility of the fuse condition through the window - Quick connection to socket Approvals (according to type): Notes Safety: ecause the output circuit can be reinstated (point 3 below), even with the fuse removed, it is important not to consider the removal of the fuse as a safety disconnect. Always isolate elsewhere before working on the circuit. UL: According to UL508A, the fuse module cannot be installed in power circuits (in which it is mandatory that a fuse certified according to UL category JDDZ be fitted). However, where the MasterInterface is connected as an output interface to a PLC no such restrictions apply, and the fuse module can be usefully employed. Multi-state fuse module 0. As delivered, the socket comes without a fuse module. However, the absent fuse is internally replaced with an electrical link - which allows the interface relay to be used without a fuse module. In this state, the peg/indicator is visually hidden and the connection is protected by a special cap. 1. With fuse module inserted after removing the cap, the fuse is positioned electrically in series with the common output terminal of the interface module (11 for EMR versions, 13+ for SSR versions, 15 for EMR timer, 15+ for SSR timer). This state is indicated by the peg/indicator. 2. If the fuse module is extracted (for example; because the fuse element has blown) the output circuit will be locked open, as this will generally be the safe option. This state is indicated by the peg/indicator. 3. In order to reinstate the output circuit it is necessary to either re-insert the fuse module (complete with functional fuse), or alternatively, return the peg/indicator to position 0 by gently applying pressure in the direction of the arrow. 24

25 39 Series - Relay interface modules A 39 SERIES Accessories way jumper link (blue) (black) (red) Rated values 36 A Possibility of multiple connection, side by side Approvals (according to type): Dual-purpose plastic separator (1.8 mm or 6.2 mm separation) y breaking off the protruding ribs (by hand), the separator becomes only 1.8 mm thick; useful for the visual separation of different groups of interfaces, or necessary for the protective separation of different voltages of neighbouring interfaces, or for the protection of cut ends of jumper links Leaving the ribs in place provides 6.2mm separation. Simply cutting (with scissors) the relevant segment(s) permits the interconnection across the separator of 2 different groups of interface relays, using the standard jumper link. Sheet of marker tags, plastic, 72 tags, 6x12 mm

26 39 SERIE S 39 Series - Relay interface modules A Accessories Approvals (according to type): Connected MasterADAPTER MasterADAPTER The MasterADAPTER permits the easy connection of A1/A2 terminals of up to MasterINTERFACE modules to PLC outputs via a 14-Pole ribbon cable, plus simple 2-wire power supply connection. Technical data Rated current (per signal path) A 1 Minimum required supply power W 3 Nominal voltage (U N ) DC 24 ( ) U N Control logic Positive switching (to A1) Power supply status indication Green LED Ambient temperature range C Terminals for 24 control logic Type of connector 14 pole, according to IEC Terminals for 24 power supply Wire strip length mm 9.5 Screw torque Nm 0.5 Max. wire size solid wire mm 2 1 x 4/2 x 1.5 AWG 1 x 12/2 x 16 stranded wire mm 2 1 x 2.5/2 x 1.5 AWG 1 x 14/2 x 16 Wiring diagram 26

93 SERIES. Timed socket for 34 series 93.68/93.69

93 SERIES. Timed socket for 34 series 93.68/93.69 93 93 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions

More information

34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay

34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay 34 Slim electromechanical PCB relays 6 34 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in terminal sockets 34.51 34.51-5010

More information

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets. 40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or

More information

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable 70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring

More information

48 Series 4C Series 58 Series Relay Interface Modules 15.8 mm wide Relay Interface Modules 15.8 mm wide

48 Series 4C Series 58 Series Relay Interface Modules 15.8 mm wide Relay Interface Modules 15.8 mm wide The FINDER Relay Interface Module ADVANTAGE Take advantage of a pre-assembled unit and make your job easier One Part Number combines relay, socket, clip and LED/suppression module UL listed devices with

More information

70 SERIES. Line monitoring relay

70 SERIES. Line monitoring relay 70 SRIS 70 SRIS lectronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window Mode, Phase

More information

Miniature PCB Relays A

Miniature PCB Relays A SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit

More information

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector Features 11.31 11.41 Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.31-1 NO 16 A output contact Sensitivity adjustment from 1 to 100 lux One module,

More information

Relay actuators & Status indicating modules

Relay actuators & Status indicating modules 19 SЕRIES Relay actuators & Status indicating modules Panels for electrical distribution FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage

More information

1 pole 17.5 mm wide 2,000 2, ,000 1,000 halogen W DC / / / / 30

1 pole 17.5 mm wide 2,000 2, ,000 1,000 halogen W DC / / / / 30 Series - Light Dependent Relay 12-16 A SERES Features.31.41 Relays for automatic control of lighting according to ambient light level - with separate light sensor.31-1 NO 16 A output contact Sensitivity

More information

pole 17.5 mm wide. electronic ballast W

pole 17.5 mm wide. electronic ballast W SERES SERES Relays for automatic control of lighting according to ambient light level - with separate light sensor.31-1 NO 16 A output contact Sensitivity adjustment from 1 to 100 lux One module, 17.5

More information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet CDC 51 1 F000 1 7 6 5 8 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 00 h, for the adjustment of the pulse time c/o contacts nd c/o contact can be

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

CONTROL PANEL COMPONENTS CONTROL PANEL SOLUTIONS

CONTROL PANEL COMPONENTS CONTROL PANEL SOLUTIONS PRODUCT PROFILE Automation Industrial applications CONTROL PANEL COMPONENTS CONTROL PANEL SOLUTIONS www.finder-us.com The Company...An Italian Brand with global presence FINDER S.p.A. - Global Headquarters

More information

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics On-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact The CT-ARE is an electronic time relay with OFF-delay. It is from the CT-E range. The CT-E range is the economic

More information

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine

More information

Cat. No. (Spring Clamp. Input Voltage

Cat. No. (Spring Clamp. Input Voltage Bulletin -HL Product Overview/Product Selection Product Selection Bulletin -HL "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications

More information

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O Characteristics Off-delay Timing Relay - 0.05s 10min - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics Off-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O Characteristics Star-Delta Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

08/07/2015

08/07/2015 DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.

More information

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

RM84 miniature relays

RM84 miniature relays RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to

More information

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O Characteristics Ondelay Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Switching relay CT-IRE with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact Data sheet Switching relay CT-IRE with 1 c/o (SPDT) contact The CT-IRE is a switching relay from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13 Data sheet Thermistor motor protection relays CM-MSS.12 and CM-MSS.13 The thermistor motor protection relays CM-MSS.12 and CM-MSS.13 monitor the winding temperature of motors and protect them from overheating,

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control

More information

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet 2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching

More information

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet 2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output Characteristics off-delay timing relay - control - 1 s..100 h - 24..240 V - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width

More information

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O Characteristics StarDelta Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Three-phase monitoring relay

Three-phase monitoring relay 2CDC 251 044 F0t08 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact The CT-ERS.12 is an electronic timer from the CT-S range with ON-delay and 10 time ranges. All electronic timers from the CT-S

More information

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13 Data sheet Thermistor motor protection relays CM-MSS.12 and CM-MSS.13 The thermistor motor protection relays CM-MSS.12 and CM-MSS.13 monitor the winding temperature of motors and protect them from overheating,

More information

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet 2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33 Data sheet Thermistor motor protection relays CM-MSS.32 and CM-MSS.33 The thermistor motor protection relays CM-MSS.32 and CM-MSS.33 monitor the winding temperature of motors and protect them from overheating,

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

Latching, Sequence and Impulse Relays Application Data

Latching, Sequence and Impulse Relays Application Data Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation

More information

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O Characteristics On-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 1C/O Product availability : Stock - Normally stocked in distribution facility Price* : 59.76 USD Main Range of product Product or component

More information

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications RSC Series RSC Series Solid State Relays Key features of the RSC series include: Slim design allows for DIN rail or panel mounting Built-in heat sink maximizes current output capability Epoxy-free design

More information

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers

More information

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet 1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models with system diagnostics Very low zero-cross turn-on voltage Input and output protection and control LED standard IP20 protection by flaps on terminals With double removable

More information

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and

More information

1.5 Solid State Relays

1.5 Solid State Relays Relays.. Solid State Relays Application s Pins Contacts AC ratings DC ratings Socket CSS Series AC Solid state, Instantaneous switching CSS-I A / 0 V S0 AC Solid state synch. to zero crossing CSS-Z A /

More information

PI84 with socket GZM80 interface relays

PI84 with socket GZM80 interface relays RM84 + GZM80 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) Min. switching current Max. inrush current Rated current

More information

Thermistor motor protection relay CM-MSS.21

Thermistor motor protection relay CM-MSS.21 Data sheet Thermistor motor protection relay CM-MSS.21 The thermistor motor protection relay CM-MSS.21 monitors the winding temperature of motors and protects them from overheating, overload and insufficient

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/ O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33 Data sheet Thermistor motor protection relays CM-MSS.32 and CM-MSS.33 The thermistor motor protection relays CM-MSS.32 and CM-MSS.33 monitor the winding temperature of motors and protect them from overheating,

More information

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.41 Data sheet Thermistor motor protection relay CM-MSS.41 The thermistor motor protection relay CM-MSS.41 monitors the winding temperature of motors and protects them from overheating, overload and insufficient

More information

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact Characteristics variable speed drive ATV320-0.75kW - 200...240V - 1 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections - terminals Housing material Main Range

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O Characteristics Current control relay 0.15A 15A, 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay type Switching capacity in VA Measurement

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions with adaptor (V) with adaptor (H) Power relays of general application AC and DC coils Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB Versions: faston 187 (4,8 x 0,5 mm); faston

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity

More information

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC Characteristics on-delay timing relay - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical

More information

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket Solid-state Timer Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating modes. Conforms

More information

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink Characteristics variable speed drive ATV32-7.5 kw - 400 V - 3 phase - with heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application Function

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC Characteristics on-delay timing relay - 0.02 s..300 h - 24..240 V AC - 2 OC Product availability : Stock - Normally stocked in distribution facility Price* : 73.00 USD Main Range of product Product or

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O Product datasheet Characteristics RM22LA32MR Level control relay RM22-L - 24..240 V AC/DC - 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay

More information

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.41 Data sheet Thermistor motor protection relay CM-MSS.41 The thermistor motor protection relay CM-MSS.41 monitors the winding temperature of motors and protects them from overheating, overload and insufficient

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main. Characteristics universal plug-in timing relay - flashing - 0.1 s..60 mn - 24..240 V AC - 2 OC Main Range of product Product or component type Discrete output type Contacts type and composition Width pitch

More information