MEGA Line RACING ELECTRONIC GmbH Haunersdorfer Str.3 D Saal a.d. Donau Description / features

Size: px
Start display at page:

Download "MEGA Line RACING ELECTRONIC GmbH Haunersdorfer Str.3 D Saal a.d. Donau Description / features"

Transcription

1 Description / features The Intelligent Autarkic Supply (IAS) has been designed as an add on system in combination with the E Clutch Actuator and / or E Shift Actuator to help comply with the FIA regulation for disengaging the drive train of stranded cars by the marshals. According to the regulation, the disengagement of the drive train has to be achieved in parallel to a disconnected car main battery. The IAS contains a suitable accumulator combined with the required functionalities to allow to boot the desired E device and achieve a disconnected drivetrain even with car master switch being "off" to enable the car to be pushed or towed. The integrated accumulator (Li Ion) is permanently charged during standard car operation to ensure sufficient capacity. Also, the IAS unit allows to reduce wiring gauge for supply of the E devices by acting as a buffer. In order to allow scalability of the accumulator capacity, the unit also offers the possibility to connect an additional accumulator to react on increased supply needs. Technical specifcations Electronic data: Operating voltage Standby current Peak current Circuit breaker Mechanical data: Dimensions L x W x H Weight Connector: Deutch 37 pin, flange mounted Deutch 37 socket, loom side Temperature range: Ambient Ordering information: Article no. Order no V nom. < 0.5 ma max. 100A not integrated approx. 146 x 88 x 35 mm 375 g AS014 35PN AS614 35SN 25 C C Hazardus goods classification: The specifications contained in this document are subject to change at any time and at the discretion of and without prior warning. accepts no responsibility for any claims or damage Page 1

2 Pin assignment Pin AUX supply out AUX supply out V supply in +13.5V supply in 31 Marshalling command in (switch to GND) 33 CAN low Dia [AWG] 1 2 Type Function AUX supply command in (switch to GND) CAN high Marshalling command E Clutch out* Marshalling command E Shift paddle up out* Marshalling command E Shift paddle down out* * Highside / lowside input configurable via software digital in data digital in data The specifications contained in this document are subject to change at any time and at the discretion of and without prior warning. accepts no responsibility for any claims or damage Page 2

3 Assembly dimensions The specifications contained in this document are subject to change at any time and at the discretion of and without prior warning. accepts no responsibility for any claims or damage Page 3

4 Mechanical dimensions The specifications contained in this document are subject to change at any time and at the discretion of and without prior warning. accepts no responsibility for any claims or damage Page 4

5 Operation diagram The specifications contained in this document are subject to change at any time and at the discretion of and without prior warning. accepts no responsibility for any claims or damage Page 5

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I Ordering Informations Type Output Input Dimensions Article No.* Voltage VE3PUID 300.2,5/L V = 0V - 300V* 3 x 400Vac 84HP/2U 582-00-03 I = 0A - 2,5A* * Delivery condition; Local Mode; LAB (L)-Control-Mode

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12- Relay Board P/N 103190 and 103338 PAGE 1 of 13 1. REVISI LOG... 2 2. OVERVIEW... 3 2.1. PART NUMBERS... 3 2.2. MODULE

More information

Digital Modules AS-i in IP20, 22,5 mm

Digital Modules AS-i in IP20, 22,5 mm Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device. Docking station Order no. 2883.. Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by qualified electricians. Always follow the relevant

More information

EATON Transformer Module

EATON Transformer Module www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC. 86-86000-0

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 USER S MANUAL VER.1 C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 MARCH 2018 User s Manual Page i USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 OVERVIEW... iii 2.0 FEATURES... iii 3.0 SPECIFICATIONS...

More information

EcoSystem to 0 10 V- Interface

EcoSystem to 0 10 V- Interface to Interface to Interface 369537i 1 03.22.19 The to Interface provides a control gateway from an link to a compatible lighting device, typically an ED driver. It allows for individual addressing of the

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah)

Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah) Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah) AA Portable Power Corp (http://www.batteryspace.com) Address: 860 S, 19 th St, Unit

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

CC COMPACT DIP SWITCH

CC COMPACT DIP SWITCH CC COMPACT DIP SWITCH COMFORTLINE DIP SWITCH C-R5 186841, 186842, 186843 Typical Applications Built-in in compact luminaires for Shop lighting Downlights Panels ComfortLine DIP switch C-R5 SELECTABLE OUTPUT

More information

INSTALLATION MANUAL SLI 50 INVERTER

INSTALLATION MANUAL SLI 50 INVERTER INSTALLATION MANUAL SLI 50 INVERTER www.unipowerco.com Manual No. SLI-50-48-3 2016 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com

More information

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim Wireless Passive Module Wireless module for Product description Wireless controllable with a Android / ios smart device No need for an external gateway device Forms automatically a wireless communication

More information

Light Control SLS ADRIA

Light Control SLS ADRIA Instruction and Mounting Manual Light Control SLS ADRIA 1 Introduction... 2 2 Safety instructions... 2 2.1 Meaning of the safety symbols... 2 2.2 General safety information... 2 3 Brief description...

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

TXM1.8RB. TX-I/O Blinds module

TXM1.8RB. TX-I/O Blinds module s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections...

More information

HP8440 Power Box. The Intelligent Power Distribution Module. Installation and User Guide for PCM Version 9.02

HP8440 Power Box. The Intelligent Power Distribution Module. Installation and User Guide for PCM Version 9.02 HP8440 Power Box The Intelligent Power Distribution Module Installation and User Guide for PCM Version 9.02 1 Introduction The Power Control Module is an innovative, intelligent and programmable module

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

picture 1: Device components

picture 1: Device components Tronic rotary dimmer with soft-lock Order-No. : 2874 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Quick reference guide 3D sensor O3D3xx

Quick reference guide 3D sensor O3D3xx Quick reference guide 3D sensor O3D3xx 80271080 / 00 11 / 2017 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...4 2.1 Safety note...4 3 Functions and features...4

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Electrical Specifications

Electrical Specifications Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max Load Max Case Tem p. ( C) Input Current Max. Input Power (W) Inrush Current (A pk/50%-µs) THD @ Max Load (%) Power Factor @ Max Load

More information

AS-Interface I/O Module

AS-Interface I/O Module AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard

More information

TPE, TPED Series 2000

TPE, TPED Series 2000 GRUNDFOS INSTRUCTIONS TPE, TPED Series 2000 Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

PRODUCT DATASHEET DATE. This report provides appropriate specifications for the FRDS GENII relay enclosure.

PRODUCT DATASHEET DATE. This report provides appropriate specifications for the FRDS GENII relay enclosure. ATTACHMENT 20 PAGE 1 Of 11 S: None 1 11 ELIGIBLE SERIAL S: PURPOSE: S/N. This report provides appropriate specifications for the FRDS GENII relay enclosure. SUMMARY: The data listed here is compiled from

More information

Installation Instructions & User Manual

Installation Instructions & User Manual Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062

More information

onlinecomponents.com

onlinecomponents.com Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information Grooved-type with Built-in Amplifier EZ-G CSM_EZ-G_DS_E_9_ with Grooved Design and Easy Settings Groove-type with groove width of 5 mm. Models are available with one or two light axes. Models are available

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009 Reference Manual DOC. REV. 4/29/2009 EPM-PS1 PC/104-Plus Power Supply Module WWW.VERSALOGIC.COM 12100 SW Tualatin Road Tualatin, OR 97062-7341 (503) 747-2261 Fax (971) 224-4708 Contents Copyright 2013

More information

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D. Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various

More information

KNX DALI Gateway Plus - User Manual

KNX DALI Gateway Plus - User Manual KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64

More information

Sivoia QS Wireless Smart Panel

Sivoia QS Wireless Smart Panel Sivoia QS Wireless 085355b 1 0.16.17 The Sivoia QS Wireless simplifies wiring and organizes installations with multiple Sivoia QS Wireless window treatments. The Sivoia QS Wireless is designed to be hardwired

More information

Abstract. GLV User Manual 1

Abstract. GLV User Manual 1 GLV User Manual 1 Abstract This user manual is a high level document that explains all operational procedures and techniques needed to operate the GLV system in a safe and effective manner. Anyone operating

More information

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital

More information

GV204 Impulse Splitter for Incremental Encoders

GV204 Impulse Splitter for Incremental Encoders Operating Manual www.genesisautomationonline.com GV204 Impulse Splitter for Incremental Encoders Product features: Programmable encoder input A, /A, B, /B, Z, /Z, for use with RS422 or TTL differential

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

5SL Miniature Circuit Breakers

5SL Miniature Circuit Breakers 5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186719, 186720, 186721, 186722, 186723, 186724, 186725, 186726, 186727, 186728 Typical Applications Built-in in compact luminaires Shop lighting Downlights EasyLine

More information

General Data. Ambient Conditions - Operating temperature: -25 C C - Storage temperature: -40 C C - Humidity: up to 95%, non-condensing

General Data. Ambient Conditions - Operating temperature: -25 C C - Storage temperature: -40 C C - Humidity: up to 95%, non-condensing 558 General Data Type Reference: Description: Approvals: ASI_BZ, ASI_BZL5 AS-Interface-Slave ASI, ccsaus, GOST-R, UkrSepro Communication - AS-Interface Specification: V2.11 - Slave profile: S-B.A.E - Connection:

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 Total System Manager PAGE 1 of 17 1. REVISION LOG... 2 2. SYSTEM OVERVIEW... 3 2.1. SCOPE... 3 2.2. FEATURES... 3 3. OPERATIONAL

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

SLD-CS-series Compact High Power Broadband Light Source Modules.

SLD-CS-series Compact High Power Broadband Light Source Modules. Superlum Broadband Light Sources SLD-CS-series Compact High Power Broadband Light Source Modules. Technical Product Specification Document ID: SL.RD.04.002.150508 December 2015 Revision: 002 ATTENTION

More information

Pololu 12V Step-Up/Step-Down Voltage Regulator S10V2F12

Pololu 12V Step-Up/Step-Down Voltage Regulator S10V2F12 Pololu 12V Step-Up/Step-Down Voltage Regulator S10V2F12 Overview The Pololu step-up/step-down voltage regulator S10V2F12 is a switching regulator (also called a switched-mode power supply (SMPS) or DC-to-DC

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY. QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

Figure 1: Device components

Figure 1: Device components , switch function, push-button function Art.-No.: 240-31 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

Installation Instructions Model PSX-12

Installation Instructions Model PSX-12 Installation Instructions Model PSX- Amp Power Supply Extender INTRODUCTI The SIEMENS Model PSX- is a high current power supply extender. The power supply extender works in conjunction with the PSC- power

More information

C9900-P208 and C9900-P209

C9900-P208 and C9900-P209 Installation and Operating instructions for C9900-P208 and C9900-P209 Power Supply Units Version: 1.5 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

GT-A81051-XXYY SERIES 5W

GT-A81051-XXYY SERIES 5W 1. ELECTRICAL SPECIFICATIONS: INPUT VOLTAGE: INPUT CURRENT: INPUT FREQUENCY: U= 100-240 VAC; N= 100-120 VAC; E = 180-264VAC < 0.2 A RMS AT 90 VAC INPUT 47-63 HZ OUTPUT VOLTAGE / CURRENT: NORTH AMERICAN

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SLD-mCS/sCS-series Miniature High Power Broadband Light Source Modules

SLD-mCS/sCS-series Miniature High Power Broadband Light Source Modules SLD-mCS/sCS-series Miniature High Power Broadband Light Source Modules Technical Product Specification Document ID: SL.RD.01.001.170215 March 2017 Revision: 002 ATTENTION ELECTROSTATIC SENSITIVE DEVICES

More information

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany. MODULES FOR STEPPER MOTORS MODULES Hardware Version V 1.10 HARDWARE MANUAL + + TMCM-1613 + + Single Axis BLDC Controller / Driver Block-commutation Hall-sensor based Analog+digital inputs / outputs Up-to

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Standalone Linear Li-Ion Battery Charger with Thermal Regulation

Standalone Linear Li-Ion Battery Charger with Thermal Regulation Standalone Linear Li-Ion Battery Charger with Thermal Regulation DESCRIPTION The UP4054A is a complete constant-current /constant-voltage linear charger for single cell lithium-ion batteries. It s TSOT23-5

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

LTC4089/-5 DESCRIPTION

LTC4089/-5 DESCRIPTION LTC4089/-5 DESCRIPTION Demonstration circuit DC929A-A/B is a monolithic high voltage (6V-36V) switching buck regulator, USB Powerpath controller, and Li-Ion battery charger. It is based on the LTC4089/-5

More information

Anytronics DMX to PWM LED Driver : Installation Guide

Anytronics DMX to PWM LED Driver : Installation Guide Anytronics DMX to PWM : Installation Guide The Anytronics DMX to PWM LED driver provides four controllable PWM outputs for controlling constant voltage LED loads connected with common anodes to a single

More information

OPENUPS 6-34V Intelligent Uninterruptible Power Supply

OPENUPS 6-34V Intelligent Uninterruptible Power Supply OPENUPS 6-34V Intelligent Uninterruptible Power Supply Installation Guide Version 1.0f P/N OPENUPS-06 Before you start Please take a moment and read this manual before you install the OPENUPS. Often times,

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , LINEAR LED DRIVERS EasyLine SIMPLE FIX 186712, 186713, 186714, 186715, 186716, 186760 Typical Applications Built-in in linear luminaires for Office lighting Weatherproof Luminaires EasyLine Simple Fix

More information

TABLE OF CONTENTS. Page 2 14

TABLE OF CONTENTS. Page 2 14 TABLE OF CONTENTS INTRODUCTION... 3 WARNING SIGNS AND THEIR MEANINGS... 3 1. PRODUCT OVERVIEW... 4 1.1. Basic features and components... 4 1.2. Supply package... 5 1.3. Robot arm specifications... 6 1.4.

More information

The Sentinel - Talon-SRX Breakout Board, rev A User s Guide

The Sentinel - Talon-SRX Breakout Board, rev A User s Guide The Sentinel - Talon-SRX Breakout Board, rev A User s Guide December 13, 2016 - document rev A Thank you for purchasing the the Sentinel Talon-SRX Breakout Board. Within this guide, you will find information

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MGate 5105-MB-EIP Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

The identified danger could cause physical and property damage.

The identified danger could cause physical and property damage. Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor

More information

3000 Series Instructions Read Instructions Carefully!

3000 Series Instructions Read Instructions Carefully! Series Instructions Read Instructions Carefully! With buttons Without buttons CURTIS INSTRUMENTS, INC. Kisco Avenue, Mt. Kisco, NY 9 Tel. (9) 9 www.curtisinst.com. Technical Specifications. Electrical

More information

14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches

14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches Miniature Pre-Leaded Vertical Enclosed Switches 14CESeries Miniature enclosed switches with outstanding harsh environment resistance, ideal for compact machinery and equipment. Easy mounting by tightening

More information

DC2U-1VR DC-DC Converter Module

DC2U-1VR DC-DC Converter Module DC2U-1VR DC-DC Converter Module Quick Start Guide Rev 1.3 08/2010 Contents Chapter 1 Overview 1.1 General Description 1.2 Image of DC2U-1VR 1.3 Getting Started 1.4 Recommended Cables Chapter 2 Details

More information

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF Power Supplies GL Series: Single & Multi Output Switchers The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500 watts for use in various

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION TECHNICAL PRODUCT DATASHEET ES-Key Climate Control Module P/N

More information

ACE-SDC-V3 Stepper Driver +Controller with USB 2.0 Communication

ACE-SDC-V3 Stepper Driver +Controller with USB 2.0 Communication ACE-SDC-V3 Stepper Driver +Controller with USB 2.0 Communication ACE-SDC-V3 Manual page 1 rev 1.00 COPYRIGHT 2008 ARCUS, ALL RIGHTS RESERVED First edition, April 2008 ARCUS TECHNOLOGY copyrights this document.

More information

Li-BMS V4. Modular Battery Management System. Datasheet. Updated in April 2017

Li-BMS V4. Modular Battery Management System. Datasheet. Updated in April 2017 We electrify the future. Modular Battery Management System Updated in April 2017 LION Smart GmbH Daimlerstraße 15 85748 Garching www.lionsmart.com +49 89 360 363 200 Overview System Description and Structure

More information