TABLE OF CONTENTS. Page 2 14

Size: px
Start display at page:

Download "TABLE OF CONTENTS. Page 2 14"

Transcription

1

2 TABLE OF CONTENTS INTRODUCTION... 3 WARNING SIGNS AND THEIR MEANINGS PRODUCT OVERVIEW Basic features and components Supply package Robot arm specifications Control box ESD button INSTALLATION General requirements Mechanical integration Mounting the robot arm Mounting an end effector Mounting the control box Electrical integration Continuous power supply requirement Robot arm connections Control box connections Page 2 14

3 INTRODUCTION This manual describes the basic features and components of the PULSE robot and details its specifications. The instructions and recommendations in the document are intended to assist the integrator in installing and commissioning a system comprising a robot arm, an end effector, and a control box. WARNING SIGNS AND THEIR MEANINGS Below, we list the warning symbols used throughout the manual and explain their meanings. The sign denotes important information that is not directly related to safety, but that the user should be aware of. The sign indicates important safety precautions the user should follow. Page 3 14

4 1. PRODUCT OVERVIEW 1.1. Basic features and components The is a lightweight arm designed for industrial use. Its possible applications include handling, pick-and-place, and various processing operations (e.g., welding, deburring, etc.). The arm comes in combination with a control box that features an integrated PC running the PULSE DESK software. Using the software, you can program the arm to move along a desired trajectory and perform different kinds of operations with an end effector. An end effector is a device or a tool connected to the end of the robot arm. Possible end effectors range from grippers for pick-and-place operations, material removal tools for cutting, drilling, and deburring to welding torches. Without an end effector mounted, the robot arm consists of the following parts (see Figure 1-1): a mounting base six interlinked segments a mounting flange for attaching an end effector 1 Mounting base 2 Axis 1 3 Axis 2 5 Axis 4 6 Axis 5 7 Axis 6 8 Mounting flange Figure 1-1: Components of the Page 4 14

5 Each of the segments includes the following elements (see Figure 1-2): an aluminum alloy tube (1) a rotating joint comprising a proprietary servo motor (2) and fitting elements (3) The modular design allows for assembling the segments into any custom configurations to increase the payload or degrees of freedom and to extend the reach (as compared to the basic specifications in Section 1.3). Figure 1-2: The elements in a segment of the PULSE robot The PULSE robots are designed for collaborative operation without safety devices and/or together with a human. Collaborative operation, however, is only possible in non-hazardous applications, where all the components, including tools, work pieces, obstacles, and other machines, pose no threat according to the application's risk assessment. You should also take into consideration the following use restrictions: Failure to observe the restrictions shall constitute a misuse, making our warranty void. It is prohibited to install and operate the PULSE robot in an explosive environment. Always conduct a risk assessment before installing and operating the PULSE robot. Avoid using the PULSE robot outside the operating parameters (see Section 1.3) Supply package When you order a PULSE robot, you receive a package containing the following: an assembled robot arm a control box an emergency shutdown (ESD) button with a connection cable a 220V mains cable a hybrid cable to connect the robot arm and the control box an Ethernet cable mounting bolts user documentation Page 5 14

6 1.3. Robot arm specifications The robot arm has the specifications as listed in Table 1-1 below. Table 1-1: Technical specifications of PULSE robots Specification Value Weight 1) Payload 1) Degrees of freedom 1) Reach 1) Repeatability Non-stop lifetime cycle Protection class Noise level Rated voltage Average power Maximum power Nominal speed Max tool center point (TCP) velocity Max TCP acceleration Acceleration time 0-1 m/s 8 kg 3 kg 6 axes 700 mm +/-0.1 mm 20,000+ hours IP30 less than 60 db 48 VDC 100 W 500 W 30 RPM 2 m/s 11 mm/s*s 0.1 s 1) The specification values can vary, depending on the customer precise requirements. There is a possibility to extend the reach, increase the weight and the payload, and to add a seventh degree of freedom. When operating the robot, make sure to comply with the following parameters: Ambient temperature: -10 C to +45 C Figure 1-3 illustrates the working range of the robot with the specifications as indicated in Table 1-1 when extended to its full length. It is essential to consider the range when installing the robot to avoid any damage to people or equipment. Page 6 14

7 Figure 1-3: The working range of the PULSE robot As mentioned in Section 1.1, the robot comprises six axes when supplied in its basic design. The axes have the lengths as shown in Figure 1-4. Figure 1-4: The lengths of the robot axes Page 7 14

8 The axes also have different motion ranges (see Table 1-2). For location of the axes, see Figure 1-1. Table 1-2: The motion ranges and maximum speeds of the robot axes Axis Motion range Maximum speed Axis 1 (base) -360 to /s Axis to /s Axis to /s Axis to /s Axis to /s Axis to /s 1.4. Control box Supplied together with the PULSE robot, the control box controls and monitors the robot's operation, providing an interface for communication between the hardware and software components of the system. In addition, it features integrated safety functions that allow for secure human-robot collaboration. Although the PULSE robot is designed for collaborative operation, the integrator should conduct a risk assessment to evaluate the need for additional safety devices (e.g., fencing, caging, etc.) at a specific robot installation. The control box is a case of the dimensions as indicated in Table 1-3. It comprises a personal computer (PC) with pre-installed control software (PULSE DESK), as well as other modules required to provide communication, safety, and other essential functions. The robot arm and the control box communicate with each other by means of a CAN connection. The control box transmits CANOpen messages with commands, while receiving and processing execution reports and telemetry from the robot arm components (e.g., servo drives, sensors, etc.). The control box supplied with the PULSE robot of basic design (see Section 1.1) has the specifications as detailed in Table 1-3 below. Table 1-3: The specifications of the control box for PULSE robots Specification Value Weight Dimensions (D x W x H) Noise level Protection rating 9 kg 260 x 483 x 88 mm Less than 60 db IP20 API implementation options C+/C++/C#/Python/ROS Page 8 14

9 1.5. ESD button For the PULSE robot, the ESD button (see Figure 1-5) is supplied as a standalone device assembled with a connection cable. Use the button to immediately stop all robot motion in an emergency, when other protective measures have proved to be impracticable or inefficient. The button is designed as a Category 1 Stop function in accordance with ISO , which implies a controlled stop with power supplied to the motors until full stop is achieved. Figure 1-5: The ESD button for the PULSE robot The actual appearance of the ESD button can differ from that shown in Figure 1-5. Each robot installation should have its own ESD button. You can place the button at any location within the reach of the person operating a specific PULSE robot. 2. INSTALLATION 2.1. General requirements The PULSE robot is partly completed machinery, which means its safe operation largely depends on its operating environment. Therefore, it is a common practice to conduct a risk assessment for each robot installation. The risk assessment is the responsibility of the integrator. If the robot is operated in a non-collaborative installation (e.g., when using a hazardous tool), the risk assessment might conclude that the integrator needs additional safety devices to protect the operator while they work with the robot. Before starting the installation, unpack the robot arm and the other components (as listed in Section 1.2) and get them ready for the mounting works. When unpacking and installing the arm, make sure not to move or rotate the robot joints manually because it can cause irreparable damage. Page 9 14

10 Installation of the PULSE robot involves the following two steps: 1. Mechanical integration 2. Electrical integration 2.2. Mechanical integration Pinching hazard! When performing the mounting works, try to keep your fingers away from the joints to avoid entrapment. Do not wear loose clothing or jewelry. Make sure long hair is tied back Mounting the robot arm With only a 120-mm footprint (see Figure 2-1), the robot arm offers good space-saving opportunities. However, when choosing a mounting location, you need to account for the robot's full working range (see Figure 1-3) to exclude collisions with other equipment or objects. To install the robot arm, follow the instructions below: 1. Unpack the robot arm and position it vertically relative to the mounting surface. The mounting surface should be flat, solid, and stable. 2. Holding the arm tight, fix it on the base with the twelve M4 mounting bolts from the supply package as shown in Figure 2-1. To improve the installation accuracy, you can also use two 5-mm dia pins. Figure 2-1: The footprint of the PULSE robot arm Page 10 14

11 Possible locations for mounting the PULSE robot arm include a horizontal surface (e.g., a table, flooring, and ceiling), a wall, or a moving platform. Alternatively, the mounting kit of the robot arm can include a mounting plate. With the mounting plate, the installation procedure will include the following steps: 1. Position the robot arm vertically and, holding it tight, fix its base to the mounting plate. Use the twelve M4 mounting bolts from the supply package as shown in Figure 2-1. For better installation accuracy, you can also use two 5-mm dia pins. 2. Fix the mounting plate assembled with the robot arm to a solid flat mounting surface Mounting an end effector The supply package for the robot arm includes a special flange for mounting an end effector (Figure 2-2). Figure 2-2: The mounting flange to attach an end effector The mounting flange features a standard ISO M6 mechanical interface (1) and a cable output (2) for connecting the end effector electrically. In case an installation requires a mechanical interface different from the standard ISO M6 one, we can modify the design of the mounting flange in accordance with your requirements. Page 11 14

12 Mounting the control box There are three mounting options available for the control box: horizontal positioning on a flat solid surface (e.g., a table) vertical positioning using a specially designed stand rack mounting (DIN 19") The choice of the mounting method will depend on the operating environment of the PULSE robot and your requirements. When mounting the control box, provide an air clearance of 50 mm from its front and back panels. 2.3 Electrical integration Before proceeding to any electrical integration works, make sure no power is supplied to the robot arm or the control box Continuous power supply requirement For safety reasons, the integrator shall be obliged to provide continuous power supply to the robot arm (e.g., installing an uninterruptible power supply, a redundancy circuit, etc.). Otherwise, we cannot guarantee that the robot arm will maintain its position in case of a power outage, which may result in serious damage to its components Robot arm connections The robot arm features the following connections: 4 digital I/O sockets 2 analog input sockets 1 power supply socket (48 V) Power is supplied to the arm via the cable connecting it with the control box. It is a hybrid cable with two shielded data pairs and three power cores. For the cable specifications, see Table 2-1. Never disconnect the cable when the robot arm is on. Page 12 14

13 Table 2-1: The hybrid cable specifications Outer diameter (O.D.) Conductor Conductor size Characteristic impedance Temperature range mm (approx.) bare stranded copper wire 0.22 qmm (control pairs) 2.50 qmm (power cores) 110 Ohm+-10% (control pairs) -25 C to +70 C (static) -15 C to +70 C (dynamic) Bending radius >12 x O. D Control box connections The control box comprises all major connections required to provide power supply of the robot system, as well as communication within it and with external devices. The connections are located on both the front and the back panels of the device. Back-panel connections On the back panel, you can find the following connections (see Figure 2-3): 8 configurable digital I/O sockets for receiving/ transmitting digital signals (1) 1 USB 3.0 port (not shown in the figure) 1 Ethernet port for integrating the system into an enterprise network (not shown in the figure) a power supply socket for connecting a 220V power cable (2) a mains fuse (3) a power switch to turn on/off the mains power supply (4) Figure 2-3: The back panel of the control box Page 13 14

14 Mains connection The power connection of the control box is in accordance with the IEC C14 standard. The electrical specifications are as indicated in Table 2-2. Table 2-2: Electrical specifications of a mains connection Parameter Min Max Unit Input voltage VAC Mains frequency Hz Standby power - 10 W Nominal operating power W Additionally, it is recommended to install an external mains switch with a fuse to power all the equipment in the robot application. Front-panel connections The connections on the front panel of the control box include (see Figure 2-4): a socket for the cable connecting the control box and the robot (1) (for the cable specifications, see Table 2-1) a socket for connecting the ESD button (2) (for details about the ESD button, see Section 1.5) Figure 2-4: The front panel of the control box Page 14 14

TABLE OF CONTENTS. Page 2 35

TABLE OF CONTENTS. Page 2 35 TABLE OF CONTENTS INTRODUCTION... 3 WARNING SIGNS AND THEIR MEANINGS... 3 1. ABOUT THE PULSE ROBOT... 4 1.1. The hardware and software... 4 1.2. The operating states of the PULSE robot... 5 1.3. Safe operation

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Hand. Desk 4. Panda research 5. Franka Control Interface (FCI) Robot Model Library. ROS support. 1 technical data is subject to change

Hand. Desk 4. Panda research 5. Franka Control Interface (FCI) Robot Model Library. ROS support. 1 technical data is subject to change TECHNICAL DATA 1, 2 Arm degrees of freedom 7 DOF payload 3 kg sensitivity joint torque sensors in all 7 axes maximum reach 855 mm joint position limits A1: -170/170, A2: -105/105, [ ] A3: -170/170, A4:

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Elfin Series Collaborative Robot

Elfin Series Collaborative Robot Elfin Series Collaborative Robot Flexible, Reliable, Efficient, Effective As industry today strives for more efficiency, increased output and reduced costs, Motion Control Products has introduced the Elfin

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF

More information

Robots. KUKA Roboter GmbH. KR AGILUS sixx. With W and C Variants Specification. Issued: Version: Spez KR AGILUS sixs V8 en (PDF)

Robots. KUKA Roboter GmbH. KR AGILUS sixx. With W and C Variants Specification. Issued: Version: Spez KR AGILUS sixs V8 en (PDF) Robots KUKA Roboter GmbH KR AGILUS sixx With W and C Variants Specification Issued: 22.07.2013 Version: Spez KR AGILUS sixs V8 en (PDF) Copyright 2013 KUKA Roboter GmbH Zugspitzstraße 140 D-86165 Augsburg

More information

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Preparing to Install the VG248

Preparing to Install the VG248 CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Standard specifications RS007LFF60

Standard specifications RS007LFF60 Standard specifications RS007LFF60 December 05, 2017 KAWASAKI HEAVY INDUSTRIES, LTD. ROBOT DIVISION Materials and specifications are subject to change without notice. Specification : (Arm): (Controller):

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

High-Speed, High-Performance Industrial Robots

High-Speed, High-Performance Industrial Robots High-Speed, High-erformance Industrial Robots up to 80 kg payload Kawasaki Robotics (USA), Inc. HIGH-SEED, HIGH-ERFORMANCE INDUSTRIAL ROBOTS The new R-Series Robots are setting the benchmark for all small

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

TS60 ESD. SCARA industrial robot Electronics industry

TS60 ESD. SCARA industrial robot Electronics industry TS60 ESD SCARA industrial robot Electronics industry A unique 4 axis and 6 axis robot range for all applications Whenever industrial need Designed to work in the most hostile speed, repeatability or reliability,

More information

InnoMedia Business VoIP ATA Models

InnoMedia Business VoIP ATA Models InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Description. 2.8 Robot Motion. Floor-mounting. Dimensions apply to IRB 6400/ Shelf-mounting

Description. 2.8 Robot Motion. Floor-mounting. Dimensions apply to IRB 6400/ Shelf-mounting Description 2.8 Robot Motion Floor-mounting Dimensions apply to IRB 64/ 3.-7 2943 694 146 3 Shelf-mounting 67 94 2871 184 3116 Figure 8 Working space of IRB 64 and IRB 64S (dimensions in mm). Product Specification

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Digital Overhead Stirrer

Digital Overhead Stirrer A Geno Technology, Inc. (USA) brand name Digital Overhead Stirrer Cat. No. BT1021 1-800-628-7730 1-314-991-6034 info@btlabsystems.com Thanks for choosing BT1021 Digital Overhead Stirrer. This operation

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

Product Information. Force/torque sensor FT-AXIA

Product Information. Force/torque sensor FT-AXIA Product Information FT-AXIA FT-AXIA Precise. Reliable. Robust. FT 6-axis force/torque sensor Rigid 6-axis force/torque sensor for precision measuring in all six degrees of freedom Field of application

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Table of Contents: TOPIC: Safe Operation: READ THIS FIRST Page: 3 Warranty 4 Specifications 4 Installation 5-7 Operating Instructions 8 Parts Diagram

Table of Contents: TOPIC: Safe Operation: READ THIS FIRST Page: 3 Warranty 4 Specifications 4 Installation 5-7 Operating Instructions 8 Parts Diagram INSTALLATION & OPERATIONS MANUAL FlexArm B-19 FlexArm Inc. Division of Midwest Specialties, Inc. 851 Industrial Drive Wapakoneta, Ohio 45895 419-738-8147 Book Part No 360740 12/2014 1 Table of Contents:

More information

MODEL 805 USER MANUAL

MODEL 805 USER MANUAL MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any

More information

Robots. KUKA Deutschland GmbH. KR AGILUS fivve. With C Variant Specification KR AGILUS. fivve. Issued: Version: Spez KR AGILUS fivve V8

Robots. KUKA Deutschland GmbH. KR AGILUS fivve. With C Variant Specification KR AGILUS. fivve. Issued: Version: Spez KR AGILUS fivve V8 Robots KUKA Deutschland GmbH KR AGILUS fivve With C Variant Specification KR AGILUS fivve Issued: 22.05.2018 Version: Spez KR AGILUS fivve V8 Copyright 2018 KUKA Deutschland GmbH Zugspitzstraße 140 D-86165

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions CubePro Prosumer 3D Printer Main PCB Replacement Guide Original Instructions 1 INTRODUCTION COPYRIGHT 2014 by All rights reserved. This document is subject to change without notice. This document is copyrighted

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-OD) This document provides information on: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

CAT. NO. R0004-C. FD-B4, FD-B4L, FD-V6, FD-V6L, FD-H5, and FD-V20 COMPLETE ROBOTIC ARC WELDING SYSTEMS

CAT. NO. R0004-C. FD-B4, FD-B4L, FD-V6, FD-V6L, FD-H5, and FD-V20 COMPLETE ROBOTIC ARC WELDING SYSTEMS CAT. NO. R0004-C FD-B4, FD-B4L, FD-V6, FD-V6L, FD-H5, and FD-V20 COMPLETE ROBOTIC ARC WELDING SYSTEMS 2 CHANGING THE FUTURE OF MANUFACTURING The ideal solution for automation of welding Intuitive Operation

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

CSM_PYF S/P2RF- -S_DS_E_2_5

CSM_PYF S/P2RF- -S_DS_E_2_5 Screwless Clamp Terminal Sockets PYF@@S/P2RF-@@-S CSM_PYF S/P2RF- -S_DS_E_2_5 New Screwless Terminal Sockets Added for MY and G2R Relays. Simplified wiring without tightening screws. Two wires can be independently

More information

INCLUDED HARDWARE REQUIRED TOOLS GETTING STARTED DISCLAIMERS! 5/32 Allen Wrench (Provided)

INCLUDED HARDWARE REQUIRED TOOLS GETTING STARTED DISCLAIMERS! 5/32 Allen Wrench (Provided) UPSIDE INCLUDED HARDWARE 8 x 5/8 Screw M6x16 REQUIRED TOOLS 5/32 Allen Wrench (Provided) GETTING STARTED Assemble on a soft surface to avoid scratching the worksurface. Hardware & tools required may vary

More information

Standard specifications ST AX ST70L-01-AX

Standard specifications ST AX ST70L-01-AX Standard specifications ST100-01-AX ST70L-01-AX 1st edition: Feb 2008 NACHI-FUJIKOSHI CORP. Robot Production Plant Table of contents 1. Outline...1 1.1. Robot...1 1.2. AX controller...1 2. Characteristic...2

More information

3/4 U CPCI Serial Case System

3/4 U CPCI Serial Case System 3/4 U CPCI Serial Case System User s Manual Product Number: 4579-634 Doc-No: 6397-345_R.0 October 05 R.0 October 05 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt, Germany

More information

Kevin-Peng Kong, Robot Application R&D Manager, October 2015 YuMi a truly collaborative industrial robot for Industry 4.0

Kevin-Peng Kong, Robot Application R&D Manager, October 2015 YuMi a truly collaborative industrial robot for Industry 4.0 Kevin-Peng Kong, Robot Application R&D Manager, October 2015 YuMi a truly collaborative industrial robot for Industry 4.0 YuMi You and Me Agenda Background Main features Inherently safe design Human -

More information

P216. Condenser fan speed controller. Product bulletin. Features

P216. Condenser fan speed controller. Product bulletin. Features P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure

More information

This overview summarizes topics described in detail later in this chapter.

This overview summarizes topics described in detail later in this chapter. 20 Application Environment: Robot Space and Motion Overview This overview summarizes topics described in detail later in this chapter. Describing Space A coordinate system is a way to describe the space

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi ) Cloud capable and communicating failsafe damper actuator for adjusting dampers in commercial HVAC applications. Failsafe Air Damper Size Up to approx. 45 sq. ft. Nominal Torque 180 in lb [20 NM] Power

More information

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs MAN0969-02 PAGE 1 Mix577/977 Module ` SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs 1 SPECIFICATIONS Analog Inputs High Resolution Steady State Current 120mA @ 24v

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Robots. KUKA Roboter GmbH KR 360 FORTEC. With F and C Variants Specification. Issued: Version: Spez KR 360 FORTEC V2

Robots. KUKA Roboter GmbH KR 360 FORTEC. With F and C Variants Specification. Issued: Version: Spez KR 360 FORTEC V2 Robots KUKA Roboter GmbH KR 360 FORTEC With F and C Variants Specification Issued: 16.04.2014 Version: Spez KR 360 FORTEC V2 Copyright 2014 KUKA Laboratories GmbH Zugspitzstraße 140 D-86165 Augsburg Germany

More information

Single-Core PVC 6491X

Single-Core PVC 6491X Single-Core PVC X 0/0 V Application PVC insulated only cable for fixed wiring purposes. Used in trunking or conduit, or may be surface mounted when used for earthing. Specifications In accordance with

More information

Sapling Converter Box

Sapling Converter Box Installation Manual Sapling Converter Box SCB-100-000-1 Version Number 1.2 Current as of March 15, 2015 The Sapling Company, Inc. (+1) 215.322.6063 P. (+1) 215.322.8498 F. 2-Wire Converter Box (SCB-100-000-1)

More information

TS60 ESD. SCARA industrial robot Electronics industry

TS60 ESD. SCARA industrial robot Electronics industry TS60 ESD SCARA industrial robot Electronics industry A unique 4 axis and 6 axis robot range for all applications Whenever industrial companies need speed, Designed to work in the most hostile repeatability

More information

TS80 ESD. SCARA industrial robot - Electronics industry

TS80 ESD. SCARA industrial robot - Electronics industry TS80 ESD SCARA industrial robot Electronics industry A unique 4 axis and 6 axis robot range for all applications Whenever industrial companies need speed, Designed to work in the most hostile repeatability

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS Online data sheet S30A-7021EK S3000 Anti Collision A B C D E F system plug not supplied with delivery Ordering information Type Part no. S30A-7021EK 1071544 Usage Can only be used in the EFI system network,

More information

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444 Product Manual 01504 (Revision B) Original Instructions RVDT Setup and Polarity Checking Tool for EG Governors T87444 Operation and Calibration Manual General Precautions Read this entire manual and all

More information

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0. Incremental 25-mm-dia. Rotary Encoder CSM DS_E_5_1 Compact Encoder with External Diameter of 25 mm Incremental model External diameter of 25 mm. Resolution of up to ppr. Be sure to read Safety Precautions

More information

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS PDS100 Programmable Dispensing System INSTRUCTION MANUAL SAFETY INSTRUCTIONS Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications

More information

KR QUANTEC K ultra. Robots. With F Variants Specification. KUKA Roboter GmbH. Issued: Version: Spez KR QUANTEC K ultra V10 KR QUANTEC

KR QUANTEC K ultra. Robots. With F Variants Specification. KUKA Roboter GmbH. Issued: Version: Spez KR QUANTEC K ultra V10 KR QUANTEC Robots KUKA Roboter GmbH KR QUANTEC K ultra With F Variants Specification KR QUANTEC K ultra Issued: 02.09.2016 Version: Spez KR QUANTEC K ultra V10 Copyright 2016 KUKA Roboter GmbH Zugspitzstraße 140

More information

EUROPE R-SERIES. up to 80 kg payload

EUROPE R-SERIES. up to 80 kg payload EUROPE R-SERIES up to 80 kg payload »Simple and friendly«into THE FUTURE»40 years of experience and state-of-the-art robot technology«the R-SERIES 1. High speed 4. Protection Kawasaki Robotics invents

More information

Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR)

Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR) Standard Module # Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR) The IRB-540 Flexi-Wrist finishing robot is specifically

More information

3+1 U CPCI Serial System

3+1 U CPCI Serial System 3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,

More information

ADN PS. Power Supply. Instruction manual

ADN PS. Power Supply. Instruction manual Power Supply Instruction manual Contents Contents For your safety... The power supply... 2 Package contents... 2 Components required for operation... 3 Product overview power supply... 4 Structuring and

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Industrial Power Supplies

Industrial Power Supplies 75-600 Watt Features Switch mode power supplies for DIN-rail mounting 4 power ranges with 3, 6, 12 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies

More information

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication 3 870 DESIO RXB Room controller for chilled ceilings and radiators with EIB bus communication RXB10.1 The RXB10.1 controller is used for temperature control in individual rooms: For chilled ceilings and

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

P216 Series Condenser Fan Speed Controller

P216 Series Condenser Fan Speed Controller P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version

More information

Schwintek Bed Tilt OEM INSTALLATION MANUAL

Schwintek Bed Tilt OEM INSTALLATION MANUAL Schwintek Bed Tilt OEM INSTALLATION MANUAL TABLE OF CONTENTS Safety Information 2 Resources Required 3 Installation 3 Racks 3 Bed Support 4 Calibration 5 Troubleshooting 6 Error Code Chart 6 Notes 7 Safety

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Manual 5 Axis CNC Interface Breakout Board Model#-DB25-1R5AM

Manual 5 Axis CNC Interface Breakout Board Model#-DB25-1R5AM Manual 5 Axis CNC Interface Breakout Board Read this manual carefully before making connections to the board. Store this manual away for further reference. Safety Notes: The electronics of the control

More information

Automatic Control Industrial robotics

Automatic Control Industrial robotics Automatic Control Industrial robotics Prof. Luca Bascetta (luca.bascetta@polimi.it) Politecnico di Milano Dipartimento di Elettronica, Informazione e Bioingegneria Prof. Luca Bascetta Industrial robots

More information

Robot Control. Robotics. Robot Control. Vladimír Smutný

Robot Control. Robotics. Robot Control. Vladimír Smutný Robot Control Robotics Robot Control Vladimír Smutný Center for Machine Perception Czech Institute for Informatics, Robotics, and Cybernetics (CIIRC) Czech Technical University in Prague Kinematic Model

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information Grooved-type with Built-in Amplifier EZ-G CSM_EZ-G_DS_E_9_ with Grooved Design and Easy Settings Groove-type with groove width of 5 mm. Models are available with one or two light axes. Models are available

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

Industrial Power Supplies

Industrial Power Supplies 50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

RobotEye RELW60. High Speed Long Wave Infra-Red Thermal Imaging System User Manual

RobotEye RELW60. High Speed Long Wave Infra-Red Thermal Imaging System User Manual RobotEye RELW60 High Speed Long Wave Infra-Red Thermal Imaging System User Manual. Unit F1, 13-15 Forrester St Kingsgrove NSW 2208 Australia ii Copyright Notice and Disclaimer Copyright 2015 ( Ocular Robotics

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Series 1780 dynamometer and thrust stand datasheet

Series 1780 dynamometer and thrust stand datasheet Series 1780 dynamometer and thrust stand datasheet Typical use Inrunner and outrunner brushless motor characterization (0-100A) Propeller characterization (max 40 ) Servo testing and control Battery endurance

More information

TS80 ESD. SCARA industrial robot - Electronics industry

TS80 ESD. SCARA industrial robot - Electronics industry TS80 ESD SCARA industrial robot Electronics industry A unique 4 axis and 6 axis robot range for all applications Whenever industrial need Designed to work in the most hostile speed, repeatability or reliability,

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Pick-it M-HD Camera Field of view

Pick-it M-HD Camera Field of view Pick-it M-HD Camera Field of view To be visible for Pick-it, all parts or FIELD OF VIEW (FOV) SIDE VIEW FRONT VIEW items of interest must be inside the DIMENSIONS field of view (FOV) of the D camera. The

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

xtablet T1600 Vehicle Holder Installation Guide

xtablet T1600 Vehicle Holder Installation Guide This document will step you through setting up the T1600 Vehicle Holder installation and tips for a safe, clean and long lasting installation. Preparing to Mount the Vehicle Holder Warning : Dock mounting

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

Product Information. Anti-collision and overload protection sensor OPS

Product Information. Anti-collision and overload protection sensor OPS Product Information OPS OPS Compliant. Highly responsive. Simplified monitoring. OPS collision and overload sensor Collision and overload protection with automatic reset for protecting robots and handling

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

Model VDL 115 Vacuum drying chambers for flammable solvents

Model VDL 115 Vacuum drying chambers for flammable solvents Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber

More information

The Flexible Heavy-Duty Robot

The Flexible Heavy-Duty Robot The Flexible Heavy-Duty Robot up to kg payload Kawasaki Robotics (USA), Inc. THE FLEXIBLE HEAVY-DUTY ROBOT The high payload long reach Z-Series robots were developed using Kawasaki s advanced technology

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information