Coastal GMDSS Sea Area А1 Marinsys-GMDSS system. Doc. number: _Ed. 1_Rev. A Data: May 2017 г. MARCOM INTEGRALES DE SISTEMAS, S.L.
|
|
- Laurence Cummings
- 5 years ago
- Views:
Transcription
1 INSTALLATION MANUAL Coastal GMDSS Sea Area А1 Marinsys-GMDSS system Doc. number: _Ed. 1_Rev. A Data: May 2017 г. MARCOM INTEGRALES DE SISTEMAS, S.L. Exclusive distributor in Russia Marynsys LLC т. (812)
2 SAFETY INSTRUCTIONS WARNING HAZARDOUS VOLTAGE. Can shock, burn or cause serious injury. Do not work inside the equipment unless totally familiar with electrical circuits. Do not approach the antenna closer than the distances shown below when the antenna is transmitting. The antenna emits radio waves that can be harmful to the human body. CAUTION Ground the transceiver unit. Ground the transceiver unit to prevent electrical shock and interference. Confirm that the power supply voltage is compatible with the voltage rating of the equipment. Connection to the wrong power supply can cause fire or damage the equipment. RF power density Description Distance on antenna aperture required by 100 W/m m IEC W/m m IEC W/m m MPE by FCC (MPE: Minimum Permissible Exposure) Turn off the power at the mains switchboard before beginning the installation. Post a warning sign near the switchboard to indicate that power should not be applied while the equipment is being installed. Electrical shock, serious injury or fire can result if the power is not turned off or is applied while the equipment is being installed. Page 2 of 31
3 TABLE OF CONTENTS SAFETY INSTRUCTIONS 2 TABLE OF CONTENTS 3 SYSTEM CONFIGURATION 4 EQUIPMENT LISTS 5 HOW TO INSTALL THE EQUIPMENT 6 CONECTIONS 10 INITIAL SETTINGS 33 Page 3 of 31
4 SYSTEM CONFIGURATION Page 4 of 31
5 EQUIPMENT LISTS Standard supply Name Type Qty Remarks VHF Transceiver Unit MST-1124/1124M 5 sets MST pcs; MST-1124M-3pcs Housing unit MSU sets With cable & connector Power supply MSPS sets With cable & connector Marinsys VIS system server MSVCS sets With cable & connector Voice Recording and MSVCR sets With cable & connector Playback server Automatic DSC ARM sets PC, 24 monitor operator workstation Automatic Voice ARM sets With cable & connector operator workstation Control and monitoring MSMR sets With cable & connector system server Automatic system control & ARM set PC, 24 monitor monitoring operator workstation PSTN Gateway MSG set With cable & connector Foot Switch with two pedals MSS sets With cable & connector Microphone with dual PTT MSM-123V 2 sets With cable & connector Microphone with PTT MSM set With cable & connector Rack 19 MSBA set With cable & connector Rack 19 MSBA set With cable & connector All cables with connector - 1 set Cables( coaxial, ASSY, LAN ) *PC for Internet & - 1 set With cable & connector *NTP server - 2 sets With GPS/Glonass antenna Optional equipment *Supplied on customer demand. Name Type Remarks Handset MSH-2123 With cable & connector Headphones with dual PTT MSH-285D With cable & connector VoIP module MSRG-123 With cable & connector VoIP module frame MSCMV-1123 With cable & connector Microphone with dual PTT MSM-123R With cable & connector Headphones with dual PTT MSH-085D With cable & connector On-line UPS - With cable & connector UPS battery pack With cable & connector Power distribution unit - With cable & connector Network switch - With cable & connector KVM switch - With cable & connector Microwave link - With cable & connector Fiber optic cable - With cable & connector Firewall - With cable & connector Page 5 of 31
6 1. HOW TO INSTALL THE EQUIPMENT 1.1 Transceiver Unit MST-1124/1124M General installation remarks The transceiver unit (can 4pcs.) installed in a housing unit model MSU Select a location where the controls can be easily operated and a location that is near the power source and the ground location. Additionally, select a location that meets the following conditions: Select a location away from water spray and water splash. The location must not be in direct sunlight, because of heat that can increase inside the unit. Leave some additional length in cables to allow a service technician to move the radio from its normal location with the cables connected. Do not install the unit where flammable gases are stored. Select a location that provides good ventilation. Leave enough space at the sides and rear of the unit for maintenance and service purposes and to provide cool air Housing unit installation Set the transceiver unit to the housing unit and tighten the knob bolts. 1.2 VHF Antenna Requirements for the dipole antenna Any good quality antenna that meets the requirements shown below can be used. Frequency range: 155 to 164 MHz VSWR, not more than: 1.5 Gain OMNI, dbi: OFFSET, dbi: Sector in vertical plane, -3dB: Impedance: 50 ohms Min. power input, W: 50 W Quality: Withstand the marine environment Temperature range, C: -50 to Installation location The location and installation of different antennas is important to ensure effective communications. Incorrectly installed antennas will degrade performance of the radio equipment and reduce the range of communications. Select the location for the antenna considering the following points. Page 6 of 31
7 VHF antennas should be placed in a position which is as elevated and free as possible, with at least 2 meters horizontal separation from constructions made by conductive materials. Ideally there should not be more than one antenna on the same level. The location of mandatory VHF antennas should be given priority compared with mobile telephone antennas. If they are located on the same level, the distance between them should be at least 5 meters Mounting procedure The basic mounting procedure for the antennas supplied by Marcom is as follows: 1. Fasten the antenna bracket to the stanchion. 2. Set the antenna to the antenna bracket and tighten bolts. 3. Screw the coaxial cable plug into the antenna. 1.3 VHF Antenna The antenna must be separated from the antennas, masts, and other objects that can cause interference. Follow the recommended separation distances in section The installation procedure is like that for the VHF antenna. 1.4 AC-DC Power Supply Power supplied to the transceiver unit, through an AC/DC redundant power supply model MSPS Installation location Select the location that meets the following conditions: Select a location that provides good ventilation. The location must be clean and dry. 1.5 VHF transceivers Housing Unit model MSU-1124 Install the MSU-1124 in rack 19" model MSBA-100-A or in rack 19" model MSBA-800. The location must meet the following points: Select a location where you can operate controls easily Select a location away from water splash. The temperature and humidity of the location must be both stable and moderate. How to install the housing unit 1. Set the housing unit to the bolts. 2. Fasten the console with the bolts to the rack 19". 3. Set MST-1124/1124M to the housing unit. Note: To connect wires after you have hung the console. 4. Fasten the MST-1124/1124M with the bolts to housing unit. Page 7 of 31
8 1.6 Installing the Rails and Server in a Rack 1. Secure the rails to the front of the rack using two screws and to the back of the rack using four screws. 2. Align the keyhole slot on the chassis rails with the corresponding pin on either side of the system and slide the chassis rails towards the front of the system until it locks into place. Secure the chassis rails to the system using screws. 3. Align and insert the ends of the chassis rails into the ends of the rails and push the system inward until the chassis rails lock into place. Page 8 of 31
9 4. Tighten the thumbscrews to secure the ears of system to the rack. 1.7 Installing Monitor of ARM-1126 and ARM-1128 To attach the monitor stand: 1. Remove the cover and place the monitor on it. 2. Fit the two tabs on the upper part of the stand to the groove on the back of the monitor. 3. Press the stand till it snaps into place. Page 9 of 31
10 2. CONNECTIONS Connect external equipment at the rear of the MSU-1124 housing unit. 1 Label Description Use VAC Power cable Connect the power cable from MSPS connector Connect external equipment at the rear of the transceiver unit model MST-1124 & MST-1124M Label Description Use 1 RX/TX antenna connector Connect VHF antenna. 2 RX antenna connector Connect RX antenna for duplex mode. 3 LAN connector Connect RJ45 connector for Ethernet connection. 4 J1 interface connector Connect to interface connector in MSU-1124 Page 10 of 31
11 Connect external equipment at the rear of the MSPS-1124 power supply. 1 2 Label Description Use VAC Power cable Connect the power cable. connector 2 24 VDC Power cable connector Connect the power cable from MSU Connect external equipment at the bottom of the monitor of ARM-1126 and ARM Label Description Use 1 Power cable connector Connect the power cable. 2 Soundbar mounting slots Attaches the Soundbar. NOTE: Please remove the plastic strip covering the mounting slots before affixing the Soundbar. 4 Display Port Connect your computer with DP cable. 7 Audio-line out Connect your speakers Other connectors No use Page 11 of 31
12 Connect external equipment at the rear of the computer of ARM-1126 and ARM Label Description Use 1 Power connector Connect the power cable. 2 DVI connector Connect with monitor. 3 Network adapter connector Connect RJ45 connector for Ethernet connection Page 12 of 31
13 Connect external equipment at the rear of the Marinsys VIS system server Label Description Use 1 KVM over ibmc Port Connect the cable from KVM. 2 Ethernet connectors Connect RJ45 connector for Ethernet connection. 3 Power cable connector Connect the power cable. Page 13 of 31
14 Connect external equipment at the rear of the Voice Recording and Playback server Label Description Use 1 KVM over ibmc Port Connect the cable from KVM. 2 Ethernet connectors Connect RJ45 connector for Ethernet connection. 3 Power cable connector Connect the power cable. Page 14 of 31
15 Connect external equipment at the rear of the Control and monitoring system server Label Description Use 1 KVM over ibmc Port Connect the cable from KVM. 2 Ethernet connectors Connect RJ45 connector for Ethernet connection. 3 Power cable connector Connect the power cable. Page 15 of 31
16 Connect external equipment at the rear of the PSTN Gateway Label Description Use 1 Power cable connector Connect the power cable. 2 Voice port Connect the PABX 3 Ethernet connectors Connect RJ45 connector for Ethernet connection.
17 2.1 VHF Antenna The VHF antenna is connected to the transceiver unit with a 50 ohm coaxial cable, type RG- 214/U. Make sure you leave some additional length in the cable for future service and maintenance. Lay the coaxial cable and fasten an M-type plug to the cable (if necessary) as follows. 1. Remove the sheath by 35 mm. 2. Bare 23 mm of the center conductor. Trim the braided shield by 10 mm and tin. 3. Slide the coupling ring on the cable. 4. Screw the plug assembly on the cable. 5. Solder plug assembly to the braided shield through the solder holes. Solder the contact sleeve to the conductor. 6. Screw the coupling ring into the plug assembly. 7. Screw the plug into the ANT connector at the rear of the transceiver unit. Sheath 35 mm 10 mm 2 mm Plug assembly Contact sleeve Solder here. Braided shield Insulator Conductor Coupling ring Solder both sides of hole. Cut conductor here. 2.2 How to Ground the Transceiver Unit Transceiver is grounded through the J1 connector at the rear of the transceiver unit. More information you can find in service manual. Page 17 of 31
18 2.3 AC/DC Power Supply Unit MSPS-1124 The AC/DC Power Supply Unit MSPS-1124 is shipped ready for connection to 220 VAC. To power on the supply, all the switches located on the front panel (the switches on the two PWS modules, the switch on the BCU module and the main switch on the GPM-124 module) must be turned ON. If the unit is powered from mains, all green LEDs will light up. Ø MAIN PW LED on the PWS modules Ø CHARGER PW LED on the PWS modules Ø POWER LED on the BCU module Ø POWER LED on the GPM module Powering on of the BCU module is more complex and happens in 4 phases, recognisable by the lighting of the front panel LEDs: Ø All the LEDs, except "OPEN FUSE", turn on; Ø One or more LEDs turn on showing the firmware version; Ø Again, all LEDs turn on; Ø Only the green "POWER" LED turns on and the BCU module operates fully. 14 Page 18 of 31
19 2.3.1 Front panel controls Figure MSPS-1124 front panel shows the front panel of the MSPS-1124 power supply. The front panel contains the following items: MSPS-1124 ON-OFF switch Switch for turning the unit on and off. BITE INH Switches to disable fault indications for the PWS and BCU modules. POWER Green LED Power on. BITE PWS 1 Red LED Fault in the PWS-1124 module no. 1. BITE PWS 2 Red LED Fault in the PWS-1124 module no. 2. BITE BCU Red LED Fault in the BCU-1124 module. FUSE OUT 1 Red LED Fuse OUT 1 (back panel) open. FUSE OUT 2 Red LED Fuse OUT 2 (back panel) open. FUSE OUT 3 Red LED Fuse OUT 3 (back panel) open. BCU-1124 Module ON-OFF switch Switch for turning the module on and off. POWER Green LED Power on. CHARGE Yellow LED Battery charging. BATTERY MODE Red LED Mains power not present and power supplied by external battery. OVERLOAD Red LED Protection from oferload. BATT. OVERHEAT Red LED Battery or BCU heat sink overheating. BITE Red LED Fault in the BCU module. OPEN FUSE Red LED Battery line fuse (Battery Fuse 25 A back panel) open. PWS-1124 Module ON-OFF switch Switch for turning the module on and off. FUSE 5A 5 A fuse on the AC line. MAIN PW Green LED DC power supply out available. CHARGER PW Green LED DC battery charging power out available. BITE Red LED Fault in the PWS-1124 module. OPEN FUSE Red LED Open fuse (FUSE 5 A). MSPS-1124 front panel MSPS-1124 front panel Page 19 of 31
20 2.3.2 Module hot swapping The PWS-1124 and BCU-1124 modules can be hot-swapped in case of need and/or for maintenance (that is, without removing supply from the other power supply components). Act as follows to replace a module: Switch off the module to be replaced; Remove the module (after removing fastening screws); Insert the new module and switch it on. More information you can find in service manual. Page 20 of 31
21 Protective earth Connect a cround wire between the ground and the ground terminal on the MSPS-1124 to prevent electrical shock. CAUTION Attach protective earth securely to the ship's ground. The protective earth (grounding) is required to prevent electrical shock. GND terminal Page 21 of 31
22 2.4 MST-1124/1124M VHF Transceiver Unit The MST-1124/1124M transceiver is supplied with the MSU-1124 rack frame, which can host up to 4units MST-1124/1124Ms and takes care of powering them from mains and managing alarm signals. Difference between models MST-1124 and MST-1124M is build in DSC modem in MST-1124 model. The operating frequency range of the MST-1124/1124M is MHz, with 25 khz or 12.5 khz channel spacing. Modulation used is RTF (G3E/F3E) for MST-1124M, DSC (G2B) only for MST-1124; the maximum RF power radiated is 40 W carriers (nominal). The MST-1124/1124M can be remotely controlled via two serial ports (RS232 and RS422) used to exchange control signals and digitally encoded audio data. It is therefore highly suitable in cases where a small bandwidth is available for remote control. Moreover, the MST-1124/1124M features IP connectivity via 100baseT Ethernet for monitoring and remote control. The device can acquire up to 5 external digital alarm signals (active-low inputs); the state of these inputs can be read through the remote control interface (via serial or IP). A 600-Ω 4W E/M port (Rx+Tx) is available, as well as a dedicated audio port for analog recording. The MST-1124/1124M is an Eurocard module that can be hosted inside a rack, called MSU-1124, which can contain up to 4 units. The MSU-1124 unit provides supply to transceivers and ensures proper cooling by means of axial fans that start operation when the temperature exceeds a threshold value. 14 Page 22 of 31
23 2.4.1 Front panel controls Figure shows the front panel of the MST-1124/1124M transceiver. The front panel contains the following items: ON-OFF switch MICRO socket Speaker 6-key keyboard Graphical LCD display OPEN FUSE LED Switch for turning the unit on and off. Socket for microphone or microtelephone with PTT switch. Speaker for audio output. Keyboard for device control. Display for visualization of device status information. Red LED signaling open fuse. Table 1: MST-1124/1124M front panel MST-1124/1124M front panel More information you can find in service manual. Page 23 of 31
24 2.5 MSU-1124 TRANSCIVER HOISTING FRAME MSU-1124 The MSU-1124 frame is designed to host MST-1124/1124M transceivers in a 19" rack, and to provide dc power for the transceivers (see the MST-1124/1124M operator and installation manual to know more about its specifications). The MSU-1124 is a 19" rack frame 4U high. Up to four MST-1124/1124M transceivers can be hosted inside a MSU The MSU-1124 can supply power to the transceivers it contains, and it can manage their ALARM and BITE signals. The frame hosts two cooling fans. The enclosure is completely built in aluminium, highly resistant to shock and vibration Module hot swapping The MST-1124/1124M VHF transciver can be hot-swapped in case of need and/or for maintenance. Act as follows to replace a module: Switch off the module to be replaced; Remove the module (after removing fastening screws); Insert the new module and switch it on. Page 24 of 31
25 2.5.2 Front panel controls Figure MSU-1124 front view shows the front panel of the MSU-1124 frame. The front panel contains the following items: ON-OFF switch FUSE POWER FAN RPS BITE BATTERY Switch for turning the unit on and off. 20 A fuse for power supply Green LED Power on. Yellow LED Fan coolers active. Red LED BITE indication from the RPS power supply showing fault. Red LED BATTERY indication from the RPS power supply showing supply from battery. ALARM 1 Red LED Alarm 1 ALARM 2 Red LED Alarm 2 ALARM 3 Red LED Alarm 3 ALARM 4 Red LED Alarm 4 ALARM 5 Red LED Alarm 5 OPEN FUSE Red LED Open fuse. MSU-1124 front panel MSU-1124 front view More information you can find in service manual. Page 25 of 31
26 2.5 Voice operator workstation model ARM Voice operator workstation model ARM-1127 The ARM-1127 represents the touch screen computer of the Marinsys VIS system. The operator interacts with the terminal through a touch screen monitor, in addition to the standard mouse and keyboard. The user will also have available, as standard equipment with the terminal, a pair of earphones(with microphone and PTT button), and integrated speakers. The ARM-1127 is presented to the operator with a single application with it sown graphical interface (GUI), user friendly and intuitive. Every operator can interact with the system through specific interfaces, with which it is possible to configure the parameters of the radio resources available. The operator can also verify the status of other operators in the network, can make full duplex calls to other terminals or PSTN lines. ARM-1127 The main functions of the ARM-1127 are: Telephone communications; Access to the remote radio devices in half duplex or duplex mode with transmission enabled by the PTT on the ARM-1127 Page 26 of 31
27 2.5.2 Audio devices and external equipment Several types of devices can be simultaneously connected to the ARM Devices such as : Microphone with dual РТТ; Headphone; Handset ; Foot switch two pedals; As shown in the figure below, it is possible to connect to the ARM-1127 up to three simultaneous audio devices (connectors are located in the rear side of the ARM-1127) or two audio devices and one foot switch with two pedals. To be specific, there are three independent audio resources each one managed by its own internal board. Connect audio devices and external equipment at the rear of the ARM More information you can find in service manual. Page 27 of 31
28 3. INITIAL SETTINGS. 3.1 How to Register the MMSI MMSI should be programmed on factory. More information you can find in service manual. 3.2 Configuration of equipment and software Configurations of all equipment and software should be fixed on factory. More information you can find in service manual. 3.3 Cable and connector for equipment All cables with connectors of all equipment should be prepared on factory. More information you can find in service manual. Page 28 of 31
29 MST-1124/1124M dimensions Side view Tx/RTx Rx J1 LAN 96.2 MST-1124/1124M dimensions Rear view Page 29 of 31
30 E ELMAN THU-1124 POWER FAN RPS BITE BATTERY ALARM 1 ALARM 2 ALARM 3 ALARM 4 ALARM OPEN FUSE F US OPEN FUSE OFF ON OPEN FUSE OFF ON OPEN FUSE OFF ON OPEN FUSE OFF ON ON ESC ENT ESC ENT ESC ENT ESC ENT OFF MICRO MICRO MICRO MICRO ELMAN RTV 1124 ELMAN RTV 1124 ELMAN RTV 1124 ELMAN RTV 1124 ALP MSU-1124 dimensions Front view MSU-1124 dimensions Top view Page 30 of 31
31 MSPS-1124 dimensions Front view MSPS-1124 dimensions Top view Page 31 of 31
32 Exclusive distributor in Russia Marynsys LLC т. (812) Marinsys LLC. 3A, Dvinskaya str., St.-Petersburg, Russia Tel Fax: Web: office@marinsys.ru
SAFETY INSTRUCTIONS WARNING DANGER CAUTION
SAFETY INSTRUCTIONS DANGER Do not work inside the equipment unless totally familiar with electrical circuits. Hazardous voltage which will cause death or serious injury exists at the following locations:
More informationThank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!
1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This Installation Guide will help you efficiently install the 1170 POS. The document
More informationIndustrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationIndustrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.
More informationFCC Regulatory Information
DVW32C Advanced Wireless Voice Gateway - Safety and Installation Product Insert Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationInnoMedia Business VoIP ATA Models
InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationLASER PLUS OPERATING INSTRUCTIONS
LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03 TABLE OF CONTENTS SYSTEM OVERVIEW
More informationOverview. Features CHAPTER
CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page
More informationDDW36A Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement
DDW36A Advanced Wireless Gateway - Safety and Installation Product Insert Federal Communications Commission (FCC) Interference Statement This device has been tested and found to comply with the limits
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationeasyraid Q24P2-U4R4 Hardware Manual
easyraid Q24P2-U4R4 Hardware Manual 42-30000-5105 SCSI Channel to Serial ATA II Disk Array System Version 1.0 easyraid Q24P2-U4R4 U320 SCSI Channel to Serial ATA II Disk Array System Hardware User Manual
More information10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual
10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1
More informationDell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001
Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationUser Manual SP2H2A-H2. HDMI 2.0 1x2 Splitter with Audio Breakout. All Rights Reserved. Version: SP2H2A-H2_2018V1.0
User Manual SP2H2A-H2 All Rights Reserved Version: SP2H2A-H2_2018V1.0 Preface Read this user manual carefully before using the product. Pictures are shown in this manual for reference only. Different models
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationPIX 515/515E. PIX 515/515E Product Overview CHAPTER
CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses
More informationPTC-101 Quick Installation Guide
PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More informationPIX 520. PIX 520 Product Overview CHAPTER
CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature
More informationPS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL
PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31
More information4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual
4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
More informationThank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!
1170 POS SYSTEM 1170 USER GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 1170
More information16-SLOT IN-BAND MANAGEMENT CHASSIS
FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS User's Guide. Version 1.6 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More information4170 POS System Installation Guide
4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document
More informationModified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.
Modified Sinewave Power Inverter 1000/1500 MW 1210, MW1215 True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220 Owner s Manual Modified Sinewave Series True Sinewave Series 1. INTRODUCTION Thank you
More informationClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter
ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter
More informationJanusRAID SA-6692J Hardware User Manual
JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationThis guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).
Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationFIBER OPTIC TRANSMISSION SYSTEM 3730 & 3530 SERIES. Digital Video with Bi-directional/Return Data. User Manual. Infinova
FIBER TIC TRANSMISSI SYSTEM 70 & 50 SERIES Digital Video with Bi-directional/Return Data User Manual Infinova Contents SERVICE NOTICE... PRODUCT DESCRIPTI... ORDERING INFORMATI... INSTALLATI... POWER SUPPLY...
More informationPackage Contents. GP Options (Made by Digital)
When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's
More informationDS-1H05 Ethernet-over-Coax Extender. User Manual
DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationPreparing to Install the VG248
CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30
More informationBASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS
OPERATING INSTRUCTIONS BASIC PA AMPLIFIER A-1031 A-1061 A-1121 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy
More informationIEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual
Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder
More informationButterfly Laser Diode Mount
LM14S2 Butterfly Laser Diode Mount Operating Manual LM14S2 Laser On TEC Driver LD Driver THORLABS, Inc. Ph: (973) 579-7227 435 Route 206N Fax: (973) 383-8406 Newton, NJ 07860 USA www.thorlabs.com 10614-D02
More informationRZ5/RZ5D/RZ6 Processor. Operator s Manual
RZ5/RZ5D/RZ6 Processor Operator s Manual RZ5/RZ5D/RZ6 Processor Operator s Manual Copyright 2010-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced
More informationVision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.
Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationTRBOnet Swift Agent A001
Radio-over-IP Gateway TRBOnet Swift Agent A001 User Manual World HQ Neocom Software 8th Line 29, Vasilyevsky Ostrov St. Petersburg, 199004, Russia US Office Neocom Software 15200 Jog Road, Suite 202 Delray
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationPTC-101-M12 Hardware Installation Guide
PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter
More informationZOTAC ZBOX User s Manual
ZOTAC ZBOX User s Manual No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationPT-7728/7828 Quick Installation Guide
PT-7728/7828 Quick Installation Guide Moxa PowerTrans Switch Edition 9.0, April 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationNature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual
Nature Power Inverters Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w Owner s Manual Modified Sinewave Series True Sinewave Series For safe and optimum performance, the Power Inverter must be
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationHardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical
More informationModular 8-Port Mid-span Power over Ethernet Injector
Modular 8-Port Mid-span Power over Ethernet Injector KPOE-800-1P KPOE-800-2P Installation Guide DOC.090201 1 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationRS-422/485 to Fiber Industrial Converter
RS-422/485 to Fiber Industrial Converter (IRF-612) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or
More informationIMC-21 Quick Installation Guide
IMC-21 Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationUser Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size
User Manual 1U LCD Keyboard Drawer KwikDraw - A Series - With KVM options - 15", 17, 19 screen size 1.1 Important Safeguards Please read all of these instructions carefully before you use the device. Save
More information8-port 10/100Base-TX Switch (INS-806) User s Guide
8-port 10/100Base-TX Switch (INS-806) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means,
More informationMoxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide
Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide First Edition, February 2012 2012 Moxa Inc. All rights reserved. P/N: 1802001016020 Overview Moxa Industrial Media Converter, which
More informationIKS-G6524A/G6824A Series Quick Installation Guide
IKS-G6524A/G6824A Series Quick Installation Guide Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:
More informationDell SC7020 Storage Controller Getting Started Guide
Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better
More informationVision OPLC V TR6/V350-J-TR6
Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More information8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual
8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationCPCI System Subrack 1 U
User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationThis 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount
More informationInstallation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation
Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4
More informationDell SC5020 and SC5020F Storage Systems Getting Started Guide
Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More informationDell SCv3000 and SCv3020 Storage System Getting Started Guide
Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements installing the module connecting the wiring using the indicators for
More informationINDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide
INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationPA Series. Available in 6.0MP and 8.0MP
Camera Quick Install Guide PA Series Available in 6.0MP and 8.0MP Thank you for purchasing a PA Series CCTV Surveillance Camera. This Quick Install Guide covers basic setup, installation and use of your
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationTELIKOU Intercom System
TELIKOU Intercom System MS-800 Main Station Instruction Manual 2006 TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in its product
More informationFollow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation
1 Introduction This document provides a hardware description of the DW-GTW-AC-E1060 (hereafter referred to as device) and step-by-step procedures for mounting and cabling the device. The device supports
More informationHP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions
HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.
More information8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX
8 Chanel HD SDI Over Fiber Transmitter and Reciever Extender User Manual L-8SDI-FE-HD-TX/RX Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW...2 1.2 FEATURE...2 1.3 APPLICATION...3 CHAPTER 2. L-8SDI-FE-HD-TX/RX
More informationAntenna Distributor ORDERCODE D1444
Antenna Distributor ORDERCODE D1444 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio TAS series bring excitement to any venue. Whether you want simple plug-&-play
More informationMaintaining E-Series Routers
Maintaining E-Series Routers 9 This chapter lists the tools, items, and steps needed for installing and uninstalling E-series components. Other maintenance procedures must be performed by an authorized
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More informationPower Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. The Hardened Ethernet Extender introduced here provides one channel for Ethernet over existing
More informationKSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-
KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More informationIndustrial 3-Port Fast Ethernet Media Converter Switches
Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationInstalling the Cisco SFS 3504 Server Switch
CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see
More informationEDS-G308 Series Quick Installation Guide
EDS-G308 Series Quick Installation Guide Moxa EtherDevice Switch Edition 6.1, September 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More information