SPC BENCHMARK 2 FULL DISCLOSURE REPORT SILICON GRAPHICS INTERNATIONAL CORP. SGI INFINITESTORAGE 5600 SPC-2 V1.4

Size: px
Start display at page:

Download "SPC BENCHMARK 2 FULL DISCLOSURE REPORT SILICON GRAPHICS INTERNATIONAL CORP. SGI INFINITESTORAGE 5600 SPC-2 V1.4"

Transcription

1 SPC BENCHMARK 2 FULL DISCLOSURE REPORT SILICON GRAPHICS INTERNATIONAL CORP. SGI INFINITESTORAGE 5600 SPC-2 V1.4 Submitted for Review: March 6, 2013

2 First Edition March 2013 THE INFORMATION CONTAINED IN THIS DOCUMENT IS DISTRIBUTED ON AN AS IS BASIS WITHOUT ANY WARRANTY EITHER EXPRESS OR IMPLIED. The use of this information or the implementation of any of these techniques is the customer s responsibility and depends on the customer s ability to evaluate and integrate them into the customer s operational environment. While each item has been reviewed by Silicon Graphics International Corp. for accuracy in a specific situation, there is no guarantee that the same or similar results will be obtained elsewhere. Customers attempting to adapt these techniques to their own environment do so at their own risk. This publication was produced in the United States. may not offer the products, services, or features discussed in this document in other countries, and the information is subject to change with notice. Consult your local Silicon Graphics International Corp. representative for information on products and services available in your area. Copyright All rights reserved. Permission is hereby granted to reproduce this document in whole or in part, provided the copyright notice as printed above is set forth in full text on the title page of each item reproduced. Trademarks SPC Benchmark 2, SPC-2, SPC-2 MBPS, and SPC-2 Price-Performance are trademarks of the Storage Performance Council. SGI, the SGI logo and InfiniteStorage are trademarks or registered trademarks of in the United States and other countries. All other brands, trademarks, and product names are the property of their respective owners.

3 Table of Contents Audit Certification... 9 Audit Certification (cont.) Letter of Good Faith Executive Summary Test Sponsor and Contact Information Revision Information and Key Dates Tested Storage Product (TSP) Description SPC-2 Reported Data Storage Capacities and Relationships Differences between the Tested Storage Configuration (TSC) and Priced Storage Configuration Priced Storage Configuration Pricing Priced Storage Configuration Diagram Priced Storage Configuration Components Configuration Information Benchmark Configuration (BC)/Tested Storage Configuration (TSC) Diagram. 19 Storage Network Configuration Host System and Tested Storage Configuration Table Benchmark Configuration/Tested Storage Configuration Diagram Host System and Tested Storage Configuration Components Customer Tunable Parameters and Options Tested Storage Configuration (TSC) Creation and Configuration SPC-2 Workload Generator Storage Configuration ASU Pre-Fill SPC-2 Data Repository SPC-2 Storage Capacities and Relationships SPC-2 Storage Capacities SPC-2 Storage Capacities and Relationships Illustration SPC-2 Storage Hierarchy Ratios Storage Capacity Utilization Logical Volume Capacity and ASU Mapping SPC-2 Test Execution Results SPC-2 Tests, Test Phases, Sequences, and s Large File Processing Test SPC-2 Workload Generator Commands and Parameters... 30

4 SPC-2 Test Results File SPC-2 Large File Processing Average s (MB/s) SPC-2 Large File Processing Average s Graph SPC-2 Large File Processing Average per Stream SPC-2 Large File Processing Average per Stream Graph SPC-2 Large File Processing Average Response Time SPC-2 Large File Processing Average Response Time Graph Large File Processing Test WRITE ONLY Test Phase SPC-2 Large File Processing/WRITE ONLY/1024 KiB Transfer Size Data Ramp-Up Period SPC-2 Large File Processing/WRITE ONLY/1024 KiB Transfer Size Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large File Processing/WRITE ONLY/1024 KiB Transfer Size Average Graph Complete SPC-2 Large File Processing/ WRITE ONLY /1024 KiB Transfer Size Average Data Rate Graph Measurement Interval () Only SPC-2 Large File Processing/ WRITE ONLY /1024 KiB Transfer Size Average Data Rate per Stream Graph SPC-2 Large File Processing/ WRITE ONLY /1024 KiB Transfer Size Average Response Time Graph SPC-2 Large File Processing/ WRITE ONLY /256 KiB Transfer Size Data Ramp-Up Period SPC-2 Large File Processing/ WRITE ONLY /256 KiB Transfer Size Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large File Processing/ WRITE ONLY /256 KiB Transfer Size Average Graph Complete SPC-2 Large File Processing/ WRITE ONLY /256 KiB Transfer Size Average Graph Measurement Interval () Only SPC-2 Large File Processing/ WRITE ONLY /256 KiB Transfer Size Average per Stream Graph SPC-2 Large File Processing/ WRITE ONLY /256 KiB Transfer Size Average Response Time Graph Large File Processing Test READ-WRITE Test Phase SPC-2 Large File Processing/READ-WRITE/1024 KiB Transfer Size Data Ramp-Up Period SPC-2 Large File Processing/READ-WRITE/1024 KiB Transfer Size Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large File Processing/ READ-WRITE/1024 KiB Transfer Size Average Data Rate Graph Complete SPC-2 Large File Processing/ READ-WRITE/1024 KiB Transfer Size Average Data Rate Graph Measurement Interval () Only... 49

5 SPC-2 Large File Processing/READ-WRITE/1024 KiB Transfer Size Average per Stream Graph SPC-2 Large File Processing/READ-WRITE/1024 KiB Transfer Size Average Response Time Graph SPC-2 Large File Processing/READ-WRITE/256 KiB Transfer Size Data Ramp-Up Period SPC-2 Large File Processing/READ-WRITE/256 KiB Transfer Size Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large File Processing/READ-WRITE/256 KiB Transfer Size Average Graph Complete SPC-2 Large File Processing/READ-WRITE/256 KiB Transfer Size Average Graph Measurement Interval () Only SPC-2 Large File Processing/READ-WRITE/256 KiB Transfer Size Average per Stream Graph SPC-2 Large File Processing/READ-WRITE/256 KiB Transfer Size Average Response Time Graph Large File Processing Test READ ONLY Test Phase SPC-2 Large File Processing/READ ONLY/1024 KiB Transfer Size Data Ramp Up Period SPC-2 Large File Processing/READ ONLY/1024 KiB Transfer Size Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large File Processing/READ ONLY/1024 KiB Transfer Size Average Graph Complete SPC-2 Large File Processing/READ ONLY/1024 KiB Transfer Size Average Graph Measurement Interval () Only SPC-2 Large File Processing/READ ONLY/1024 KiB Transfer Size Average per Stream Graph SPC-2 Large File Processing/READ ONLY/1024 KiB Transfer Size Average Response Time Graph SPC-2 Large File Processing/READ ONLY/256 KiB Transfer Size Data Ramp-Up Period SPC-2 Large File Processing/READ ONLY/256 KiB Transfer Size Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large File Processing/READ ONLY/256 KiB Transfer Size Average Graph Complete SPC-2 Large File Processing/READ ONLY/256 KiB Transfer Size Average Graph Measurement Interval () Only SPC-2 Large File Processing/READ ONLY/256 KiB Transfer Size Average per Stream Graph SPC-2 Large File Processing/READ ONLY/256 KiB Transfer Size Average Response Time Graph Large Database Query Test SPC-2 Workload Generator Commands and Parameters... 64

6 SPC-2 Test Results File SPC-2 Large Database Query Average s (MB/s) SPC-2 Large Database Query Average s Graph SPC-2 Large Database Query Average per Stream SPC-2 Large Database Query Average per Stream Graph SPC-2 Large Database Query Average Response Time SPC-2 Large Database Query Average Response Time Graph Large Database Query Test 1024 KIB TRANSFER SIZE Test Phase SPC-2 Large Database Query/1024 KiB Transfer Size/4 Outstanding I/Os Data Ramp-Up Period SPC-2 Large Database Query/1024 KiB Transfer Size/4 Outstanding I/Os Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large Database Query/1024 KiB Transfer Size/4 Outstanding I/Os Average Graph Complete SPC-2 Large Database Query/1024 KiB Transfer Size/4 Outstanding I/Os Average Graph Measurement Interval () Only SPC-2 Large Database Query/1024 KiB Transfer Size/4 Outstanding I/Os Average per Stream Graph SPC-2 Large Database Query/1024 KiB Transfer Size/4 Outstanding I/Os Average Response Time Graph SPC-2 Large Database Query/1024 KiB Transfer Size/1 Outstanding I/O Data Ramp-Up Period SPC-2 Large Database Query/1024 KiB Transfer Size/1 Outstanding I/O Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large Database Query/1024 KiB Transfer Size/1 Outstanding I/O Average Graph Complete SPC-2 Large Database Query/1024 KiB Transfer Size/1 Outstanding I/O Average Graph Measurement Interval () Only SPC-2 Large Database Query/1024 KiB Transfer Size/1 Outstanding I/O Average per Stream Graph SPC-2 Large Database Query/1024 KiB Transfer Size/1 Outstanding I/O Average Response Time Graph Large Database Query Test 64 KIB TRANSFER SIZE Test Phase SPC-2 Large Database Query/64 KiB Transfer Size/4 Outstanding I/Os Data Ramp-Up Period SPC-2 Large Database Query/64 KiB Transfer Size/4 Outstanding I/Os Data Measurement Interval, Run-Out, and Ramp-Down Periods SPC-2 Large Database Query/64 KiB Transfer Size/4 Outstanding I/Os Average Data Rate Graph Complete SPC-2 Large Database Query/64 KiB Transfer Size/4 Outstanding I/Os Average Data Rate Graph Measurement Interval () Only... 80

7 SPC-2 Large Database Query/64 KiB Transfer Size/4 Outstanding I/Os Average Data Rate per Stream Graph SPC-2 Large Database Query/64 KiB Transfer Size/4 Outstanding I/Os Average Response Time Graph SPC-2 Large Database Query/64 KiB Transfer Size/1 Outstanding I/O Data Ramp-Up Period SPC-2 Large Database Query/64 KiB Transfer Size/1 Outstanding I/O Data Measurement Interval, Run-Out, and Ramp-Down Period SPC-2 Large Database Query/64 KiB Transfer Size/1 Outstanding I/O Average Data Rate Graph Complete SPC-2 Large Database Query/64 KiB Transfer Size/1 Outstanding I/O Average Data Rate Graph Measurement Interval () Only SPC-2 Large Database Query/64 KiB Transfer Size/1 Outstanding I/O Average Data Rate per Stream Graph SPC-2 Large Database Query/64 KiB Transfer Size/1 Outstanding I/O Average Response Time Graph Video on Demand Delivery Test SPC-2 Workload Generator Commands and Parameters SPC-2 Test Results File SPC-2 Video on Demand Delivery Data Video on Demand Delivery Test TEST RUN DATA BY INTERVAL SPC-2 Video on Demand Delivery Average Graph SPC-2 Video on Demand Delivery Average per Stream Graph SPC-2 Video on Demand Delivery Average Response Time Graph SPC-2 Video on Demand Delivery Maximum Response Time Graph Data Persistence Test SPC-2 Workload Generator Commands and Parameters Data Persistence Test Results File Data Persistence Test Results Priced Storage Configuration Availability Date Anomalies or Irregularities Appendix A: SPC-2 Glossary Decimal (powers of ten) Measurement Units Binary (powers of two) Measurement Units SPC-2 Data Repository Definitions SPC-2 Data Protection Levels SPC-2 Test Execution Definitions I/O Completion Types SPC-2 Components Appendix B: Customer Tunable Parameters and Options... 99

8 HBA Parameters Storage Array Parameters Appendix C: Tested Storage Configuration (TSC) Creation Storage Array Volume Creation SPC-2 Logical Volume Discovery SPC2_RAID6_Config.script Appendix D: SPC-2 Workload Generator Storage Commands and Parameters ASU Pre-Fill Common Commands/Parameters LFP, LDQ, VOD and Persistence Large File Processing Test (LFP) Large Database Query Test (LDQ) Video on Demand Delivery (VOD) Persistence 1 (write phase) Persistence 2 (read phase) Appendix E: SPC-2 Workload Generator Execution Commands and Parameters ASU Pre-Fill, Large File Processing Test, Large Database Query Test, Video on Demand Delivery Test, and Persistence Persistence

9 AUDIT CERTIFICATION

10 AUDIT CERTIFICATION (CONT.)

11 LETTER OF GOOD FAITH

12 EXECUTIVE SUMMARY Page 12 of 110 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor Primary Contact Test Sponsor Alternate Contact Auditor Test Sponsor and Contact Information Floyd Christofferson Landing Parkway Fremont, CA Phone: (510) FAX: (270) Jerry Lohr Landing Parkway Fremont, CA Phone: (510) Storage Performance Council Walter E. Baker 643 Bair Island Road, Suite 103 Redwood City, CA Phone: (650) FAX: (650) Revision Information and Key Dates Revision Information and Key Dates SPC-2 Specification revision number V1.4 SPC-2 Workload Generator revision number V1.2 Date Results were first used publicly March 6, 2013 Date FDR was submitted to the SPC March 6, 2013 Date the TSC will be available for shipment to customers April 8, 2013 Date the TSC completed audit certification February 27, 2013

13 EXECUTIVE SUMMARY Page 13 of 110 Tested Storage Product (TSP) Description The IS5600 storage system meets both demanding performance and capacity requirements of science and technology, simulation modeling, and decision support in the most efficient footprint with extreme simplicity, reliability, and scalability. This next generation storage system is unsurpassed at supporting high-performance file systems and bandwidthintensive applications in the most efficient footprint. And its fully redundant I/O paths, advanced protection features, and proactive support monitoring and services provide the highest levels (99.999%) of availability, integrity, and security. SPC-2 Tested Storage Configuration is the IS5600 generic version of the platform with settings documented in Appendix B. The generic version is ideal for customers integrating the platform into heterogeneous environments. In addition the IS5600 is available with especially tuned firmware intended for SGI high-performance compute environments. Versatility extends to the platform itself: The IS5600 comes with 6Gb/s SAS and three drive enclosure options supporting high performance and nearline SAS drives, selfencrypting drives (SEDs), and solid state disk (SSDs). All of the drive types and enclosures can be intermixed in a single system, which can be expanded to support up to 384 drives. The IS5600 controllers can be housed within the ultra-dense 4U 60-drive enclosures used here or in the available 12- and 24-drive enclosures. IS5600 is based on a field-proven 7th generation architecture designed to provide continuous access to data with its redundant hot - swappable components, automated path failover, online administration, proactive drive monitoring, a highly serviceable design, and SGI s worldwide support.

14 EXECUTIVE SUMMARY Page 14 of 110 SPC-2 Reported Data SPC-2 Reported Data consists of three groups of information: The following SPC-2 Primary Metrics, which characterize the overall benchmark result: SPC-2 MBPS SPC-2 Price Performance Application Storage Unit (ASU) Capacity Supplemental data to the SPC-2 Primary Metrics. Total Price Data Protection Level Currency Used Target Country Reported Data for each SPC Test: Large File Processing (LFP), Large Database Query (LDQ), and Video on Demand Delivery (VOD) Test. SPC-2 MBPS represents the aggregate data rate, in megabytes per second, of all three SPC-2 workloads: Large File Processing (LFP), Large Database Query (LDQ), and Video on Demand (VOD). SPC-2 Price-Performance is the ratio of Total Price to SPC-2 MBPS. ASU (Application Storage Unit) Capacity represents the total storage capacity available to be read and written in the course of executing the SPC-2 benchmark. Total Price includes the cost of the Priced Storage Configuration plus three years of hardware maintenance and software support as detailed on page 17. Data Protection Level of Protected 2 using RAID-6, which provides double-parity RAID protection against data loss. Protected 2: The single point of failure of any component in the configuration will not result in permanent loss of access to or integrity of the SPC-2 Data Repository. Currency Used is formal name for the currency used in calculating the Total Price and SPC-2 Price-Performance. That currency may be the local currency of the Target Country or the currency of a difference country (non-local currency). The Target Country is the country in which the Priced Storage Configuration is available for sale and in which the required hardware maintenance and software support is provided either directly from the Test Sponsor or indirectly via a third-party supplier.

15 EXECUTIVE SUMMARY Page 15 of 110 SPC-2 Reported Data SPC-2 MBPS SPC-2 Price-Performance ASU Capacity (GB) Total Price Data Protection Level 8, $ , $141, Protected 2 (RAID-6) The above SPC-2 MBPS value represents the aggregate data rate of all three SPC-2 workloads: Large File Processing (LFP), Large Database Query (LDQ), and Video On Demand (VOD) Currency Used: U.S. Dollars Target Country: USA SPC-2 Large File Processing (LFP) Reported Data (MB/second) Number of Streams per Stream Price-Performance LFP Composite 9, $15.02 Write Only: 1024 KiB Transfer 6, KiB Transfer 6, Read-Write: 1024 KiB Transfer 10, KiB Transfer 9, Read Only: 1024 KiB Transfer 12, KiB Transfer 11, Test Phases: (Write Only, Read-Write, and Read Only). SPC-2 Large Database Query (LDQ) Reported Data (MB/second) Number of Streams per Stream Price-Performance LDQ Composite 11, $ KiB Transfer Size 4 I/Os Outstanding 12, I/O Outstanding 12, KiB Transfer Size 4 I/Os Outstanding 11, I/O Outstanding 8,806.61p p 72 gg g p Test Phases: (1024 KiB and 64 KiB Transfer Sizes). SPC-2 Video On Demand (VOD) Reported Data (MB/second) Number of Streams per Stream Price-Performance 5, , $23.97

16 EXECUTIVE SUMMARY Page 16 of 110 Storage Capacities and Relationships The following diagram (not to scale) and table document the various storage capacities, used in this benchmark, and their relationships, as well as the storage utilization values required to be reported. Application Storage Unit (ASU) Capacity 28, GB 12 SPC-2 Logical Volumes, 2, GB per volume Addressable Storage Capacity 28, GB Configured Storage Capacity 35, GB Physical Storage Capacity 36, GB Data Protection (RAID-6) 7, GB Global Storage Overhead GB SPC-2 Storage Capacity Utilization Application Utilization 79.86% Protected Application Utilization 99.82% Unused Storage Ratio 0.00% Application Utilization: Total ASU Capacity (28, GB) divided by Physical Storage Capacity (36, GB). Protected Application Utilization: Total ASU Capacity (28, GB) plus total Data Protection Capacity (7, GB) minus unused Data Protection Capacity (0.000 GB) divided by Physical Storage Capacity (36, GB). Unused Storage Ratio: Total Unused Capacity (0.000 GB) divided by Physical Storage Capacity (36, GB) and may not exceed 45%. Detailed information for the various storage capacities and utilizations is available on pages in the Full Disclosure Report.

17 EXECUTIVE SUMMARY Page 17 of 110 Differences between the Tested Storage Configuration (TSC) and Priced Storage Configuration The generic NVSRAM and modified settings on the TSC were replaced with the SGI HPC NVSRAM. That change if applied to the TSC would not result in a negative impact to the reported SPC-2 performance data. In addition, the SGI logo was installed on the appropriate faceplate. Priced Storage Configuration Pricing Unit Product Maintenance Extended Marketing Code Description Quantity List Price Ext Price Unit Price Ext Price Price HBA 6Gb SAS PCie3 2extx4 SFF8088 Mini SAS ports, LP, supports up to 1024 PCIE-SAS E drives, JBOD 4 $ $3, $0.00 $0.00 $3, X-SAS-2M-Z 2 meter SAS cable, MiniSAS to MiniSAS 8 $ $1, $0.00 $0.00 $1, IS5600, 4U 60bay, 24GB cache, Duplex, S8 Eight 6Gb SAS Host Ports 1 $91, $91, $4, $4, $96, IS-DMODULE60-SAS 60 bay drive enclosure for IS5000 Family 1 $18, $18, $1, $1, $20, GB 15K SAS 2.5" PI&FDE 60bay IS-D300-I60-G pack for IS5000/IS5000 SP Family 12 $8, $99, $0.00 $0.00 $99, SC7-ISSM-EE-10 Media DVD ISSM EE for Windows for IS $1, $1, $ $ $2, IS-DATA RAID sw impl for up to 1/2 rack storage system, includes knowledge transfer & documentation 1 $1, $1, $0.00 $0.00 $1, IS-HWINST-STOR Base hardware deployment of up to 2 racks of SGI storage system 1 $1, $1, $0.00 $0.00 $1, Installation of dense storage IS-DENSE-STOR-UPG expansion and drive package 1 $1, $1, $0.00 $0.00 $1, Totals without discount $221, $6, $228, Package discount of 38% $86, Final Total $141, The above pricing includes the following: Acknowledgement of new and existing hardware and/or software problems within four hours. Onsite presence of a qualified maintenance engineer or provision of a customer replaceable part within four hours of the above acknowledgement for any hardware failure that results in an inoperative Priced Storage Configuration component.

18 EXECUTIVE SUMMARY Page 18 of 110 Priced Storage Configuration Diagram 4 Dual PCIe 6Gb SAS HBAs Dual-Active Controllers with: 24 GB cache, 12 GB per controller GB, 2.5, 15K RPM SAS disk drives 5 Drawers each with 12 disk drives IS5600 Expansion Enclosure with: GB, 2.5, 15K RPM SAS disk drives 5 Drawers each with 12 disk drives Priced Storage Configuration Components Priced Storage Configuration: 4 dual port 6 Gb SAS PCIe HBAs ISSM EE for Windows for IS5500 SGI InfiniteStorage 5600 Dual-Active Controllers with: 24 GB cache, 12 GB per controller 8 6 Gb x4 SAS host connections, 4 ports per controller (8 ports used) 2 6 Gb x4 SAS drive connections, 5 per controller, (10 ports used) 1 IS5600 Expansion Enclosure GB, 2.5, 15K RPM SAS disk drives 60 disk drives in the controller enclosure 60 disk drives in the IS5600 Expansion Enclosure

19 CONFIGURATION INFORMATION Page 19 of 110 CONFIGURATION INFORMATION This portion of the Full Disclosure Report documents and illustrates the detailed information necessary to recreate the Benchmark Configuration (BC), including the Tested Storage Configuration (TSC), so that the SPC-2 benchmark result produced by the BC may be independently reproduced. In each of the following sections of this document, the appropriate Full Disclosure Report requirement, from the SPC-2 benchmark specification, is stated in italics followed by the information to fulfill the stated requirement. Benchmark Configuration (BC)/Tested Storage Configuration (TSC) Diagram Clause The FDR will contain a one page BC/TSC diagram that illustrates all major components of the BC/TSC. The Benchmark Configuration (BC)/Tested Storage Configuration (TSC) is illustrated on page 20. Storage Network Configuration Clause If a storage network was configured as a part of the Tested Storage Configuration and the Benchmark Configuration described in Clause contains a high-level illustration of the network configuration, the Executive Summary will contain a one page topology diagram of the storage network as illustrated in Figure The Benchmark Configuration (BC)/Tested Storage Configuration (TSC) was configured with local storage and, as such, did not employ a storage network. Host System and Tested Storage Configuration Table Clause The FDR will contain a table that lists the major components of each Host System and the Tested Storage Configuration. The components that comprise each Host System and the Tested Storage Configuration are listed in the table that appears on page 21.

20 CONFIGURATION INFORMATION Page 20 of 110 Benchmark Configuration/Tested Storage Configuration Diagram 2 Dell PowerEdge R720 servers Microsoft Windows Server 2008 R2 Enterprise Edition w/sp1 4 LSI e Dual 6gb SAS HBAs (2 HBAs per server) NetApp E5560 Storage System Dual-Active Controllers with: 24 GB cache, 12 GB per controller GB, 2.5, 15K RPM SAS disk drives 5 Drawers each with 12 disk drives Expansion Enclosure with: GB, 2.5, 15K RPM SAS disk drives 5 Drawers each with 12 disk drives

21 CONFIGURATION INFORMATION Page 21 of 110 Host System and Tested Storage Configuration Components Host Systems: 2 Dell PowerEdge R720 servers each with: 2 Intel Xeon E5-2650; 8 cores each, 16 logical processors each, 2.00 Ghz, 2 MB L2 cache, 20 MB L3 cache 32 GB main memory Microsoft Windows Server 2008 R2 Enterprise, SP1 Build 7601 PCIe Tested Storage Configuration (TSC) 4 Emulex LPe12002 M8 dual-port FC HBAs SANtricity ES Storage Manager NetApp E5560 Storage System Dual Active Controllers with: 24 GB cache, 12 GB per controller 8 6 Gb x4 SAS host connections, 4 per controller (8 used) 10 6 Gb x4 SAS drive connections, 5 per controller (10 used) 1 Expansion Enclosure GB, 2.5, 15K RPM SAS disk drives 60 disk drives in the controller module 60 disk drives in the Expansion Enclosure

22 CONFIGURATION INFORMATION Page 22 of 110 Customer Tunable Parameters and Options Clause All Benchmark Configuration (BC) components with customer tunable parameter and options that have been altered from their default values must be listed in the FDR. The FDR entry for each of those components must include both the name of the component and the altered value of the parameter or option. If the parameter name is not self-explanatory to a knowledgeable practitioner, a brief description of the parameter s use must also be included in the FDR entry. Appendix B: Customer Tunable Parameters and Options on page 99 contains the customer tunable parameters and options that have been altered from their default values for this benchmark. Tested Storage Configuration (TSC) Creation and Configuration Clause The Full Disclosure Report must include sufficient information to recreate the logical representation of the Tested Storage Configuration (TSC). In addition to customer tunable parameters and options (Clause ), that information must include, at a minimum: A diagram and/or description of the following: All physical components that comprise the TSC. Those components are also illustrated in the BC Configuration Diagram in Clause and the Storage Network Configuration Diagram in Clause The logical representation of the TSC, configured from the above components that will be presented to the SPC-2 Workload Generator. Listings of scripts used to create the logical representation of the TSC. If scripts were not used, a description of the process used with sufficient detail to recreate the logical representation of the TSC. Appendix C: Tested Storage Configuration (TSC) Creation on page 101 contains the detailed information that describes how to create and configure the logical TSC. SPC-2 Workload Generator Storage Configuration Clause The Full Disclosure Report will include all SPC-2 Workload Generator storage configuration commands and parameters used in the SPC-2 benchmark measurement. The SPC-2 Workload Generator storage configuration commands and parameters for this measurement appear in Appendix D: SPC-2 Workload Generator Storage Commands and Parameters on page 104.

23 CONFIGURATION INFORMATION Page 23 of 110 ASU Pre-Fill Clause The SPC-2 ASU is required to be completely filled with specified content prior to the execution of audited SPC-2 Tests. The content is required to consist of random data pattern such as that produced by an SPC recommended tool. The configuration file used to complete the required ASU pre-fill appears in Appendix D: SPC-2 Workload Generator Storage Commands and Parameters on page 104.

24 DATA REPOSITORY Page 24 of 110 SPC-2 DATA REPOSITORY This portion of the Full Disclosure Report presents the detailed information that fully documents the various SPC-2 storage capacities and mappings used in the Tested Storage Configuration. SPC-2 Data Repository Definitions on page 94 contains definitions of terms specific to the SPC-2 Data Repository. In each of the following sections of this document, the appropriate Full Disclosure Report requirement, from the SPC-2 benchmark specification, is stated in italics followed by the information to fulfill the stated requirement. SPC-2 Storage Capacities and Relationships Clause Two tables and an illustration documenting the storage capacities and relationships of the SPC-2 Storage Hierarchy (Clause 2.1) shall be included in the FDR. SPC-2 Storage Capacities The Physical Storage Capacity consisted of 36,000 GB distributed over 120 disk drives each with a formatted capacity of 300 GB. There was GB (0.00%) of Unused Storage within the Physical Storage Capacity. Global Storage Overhead consisted of GB (0.18%) of the Physical Storage Capacity. There was GB (0.00%) of Unused Storage within the Configured Storage Capacity. The Total ASU Capacity utilized 100% of the Addressable Storage Capacity resulting in GB (0.00%) of Unused Storage within the Addressable Storage Capacity. The Data Protection (RAID-6) capacity was 7, GB of which 7, GB was utilized. The total Unused Storage was GB. Note: The configured Storage Devices may include additional storage capacity reserved for system overhead, which is not accessible for application use. That storage capacity may not be included in the value presented for Physical Storage Capacity. SPC-2 Storage Capacities Storage Hierarchy Component Units Capacity Total ASU Capacity Gigabytes (GB) 28, Addressable Storage Capacity Gigabytes (GB) 28, Configured Storage Capacity Gigabytes (GB) 35, Physical Storage Capacity Gigabytes (GB) 36, Data Protection (RAID-6) Gigabytes (GB) 7, Required Storage Gigabytes (GB) Global Storage Overhead Gigabytes (GB) Total Unused Storage Gigabytes (GB) 0.000

25 DATA REPOSITORY Page 25 of 110 SPC-2 Storage Capacities and Relationships Illustration The various storage capacities configured in the benchmark result are illustrated below (not to scale). Application Storage Unit (ASU) Capacity 28, GB 12 SPC-2 Logical Volumes, 2, GB per volume Addressable Storage Capacity 28, GB Configured Storage Capacity 35, GB Physical Storage Capacity 36, GB Data Protection (RAID-6) 7, GB Global Storage Overhead GB SPC-2 Storage Hierarchy Ratios Addressable Storage Capacity Configured Storage Capacity Physical Storage Capacity Total ASU Capacity % 80.00% 79.86% Data Protection (RAID-6) 20.00% 19.96% Addressable Storage Capacity 80.00% 79.86% Required Storage 0.00% Configured Storage Cap5acity 99.82% Global Storage Overhead 0.18% Unused Storage: Addressable 0.00% Configured 0.00% Physical 0.00%

26 DATA REPOSITORY Page 26 of 110 Storage Capacity Utilization Clause The FDR will include a table illustrating the storage capacity utilization values defined for Application Utilization (Clause 2.8.1), Protected Application Utilization (Clause 2.8.2), and Unused Storage Ratio (Clause 2.8.3). Clause 2,8.1 Application Utilization is defined as Total ASU Capacity divided by Physical Storage Capacity. Clause 2,8.2 Protected Application Utilization is defined as (Total ASU Capacity plus total Data Protection Capacity minus unused Data Protection Capacity) divided by Physical Storage Capacity. Clause 2,8.3 Unused Storage Ratio is defined as Total Unused Capacity divided by Physical Storage Capacity and may not exceed 45%. SPC-2 Storage Capacity Utilization Application Utilization 79.86% Protected Application Utilization 99.82% Unused Storage Ratio 0.00% Logical Volume Capacity and ASU Mapping Clause A table illustrating the capacity of the Application Storage Unit (ASU) and the mapping of Logical Volumes to ASU will be provided in the FDR. Capacity must be stated in gigabytes (GB) as a value with a minimum of two digits to the right of the decimal point. Each Logical Volume will be sequenced in the table from top to bottom per its position in the contiguous address space of the ASU. Each Logical Volume entry will list its total capacity, the portion of that capacity used for the ASU, and any unused capacity. Logical Volume (LV) Capacity and Mapping ASU (28, GB) Total Capacity (GB) Capacity Used (GB) Capacity Unused (GB) Logical Volumes , per LV 2, per LV per LV See the Storage Definition (sd) entries in Appendix D: SPC-2 Workload Generator Storage Commands and Parameters on page 104 for more detailed configuration information.

27 SPC-2 TEST EXECUTION RESULTS Page 27 of 110 SPC-2 TESTS, TEST PHASES, TEST RUN SEQUENCES, AND TEST RUNS SPC-2 TEST EXECUTION RESULTS This portion of the Full Disclosure Report documents the results of the various SPC-2 Test, Test Phases, Sequences, and s. Protected 1: The single point of failure of any storage device in the configuration will not result in permanent loss of access to or integrity of the SPC-2 Data Repository. Protected 2: The single point of failure of any component in the configuration will not result in permanent loss of access to or integrity of the SPC-2 Data Repository. SPC-2 Test Execution Definitions on page 95 contains definitions of terms specific to the SPC-2 Data Repository. In each of the following sections of this document, the appropriate Full Disclosure Report requirement, from the SPC-2 benchmark specification, is stated in italics followed by the information to fulfill the stated requirement. SPC-2 Tests, Test Phases, Sequences, and s The SPC-2 benchmark consists of the following Tests, Test Phases, Sequences, and s: Data Persistence Test Data Persistence 1 Data Persistence 2 Large File Processing Test WRITE ONLY Test Phase Sequence KiB Transfer maximum number of Streams KiB Transfer 50% of 1 s Streams value KiB Transfer 25% of 1 s Streams value KiB Transfer 12.5% of 1 s Streams value KiB Transfer single (1) Stream Sequence KiB Transfer maximum number of Streams KiB Transfer 50% of 6 s Streams value KiB Transfer 25% of 6 s Streams value KiB Transfer 12.5% of 6 s Streams value KiB Transfer single (1) Stream READ-WRITE Test Phase Sequence KiB Transfer maximum number of Streams KiB Transfer 50% of 11 s Streams value KiB Transfer 25% of 11 s Streams value KiB Transfer 12.5% of 11 s Streams value KiB Transfer single (1) Stream Sequence KiB Transfer maximum number of Streams KiB Transfer 50% of 16 s Streams value

28 SPC-2 TEST EXECUTION RESULTS Page 28 of 110 SPC-2 TESTS, TEST PHASES, TEST RUN SEQUENCES, AND TEST RUNS KiB Transfer 25% of 16 s Streams value KiB Transfer 12.5% of 16 s Streams value KiB Transfer single (1) Stream READ ONLY Test Phase Sequence KiB Transfer maximum number of Streams KiB Transfer 50% of 21 s Streams value KiB Transfer 25% of 21 s Streams value KiB Transfer 12.5% of 21 s Streams value KiB Transfer single (1) Stream Sequence KiB Transfer maximum number of Streams KiB Transfer 50% of 26 s Streams value KiB Transfer 25% of 26 s Streams value KiB Transfer 12.5% of 26 s Streams value KiB Transfer single (1) Stream Large Database Query Test 1024 KIB TRANSFER SIZE Test Phase Sequence I/O Requests Outstanding maximum number of Streams 2 4 I/O Requests Outstanding 50% of 1 s Streams value 3 4 I/O Requests Outstanding 25% of 1 s Streams value 4 4 I/O Requests Outstanding 12.5% of 1 s Streams value 5 4 I/O Requests Outstanding single (1) Stream Sequence I/O Request Outstanding maximum number of Streams 7 1 I/O Request Outstanding 50% of 6 s Streams value 8 1 I/O Request Outstanding 25% of 6 s Streams value 9 1 I/O Request Outstanding 12.5% of 6 s Streams value 10 1 I/O Request Outstanding single (1) Stream 64 KIB TRANSFER SIZE Test Phase Sequence I/O Requests Outstanding maximum number of Streams 12 4 I/O Requests Outstanding 50% of 11 s Streams value 13 4 I/O Requests Outstanding 25% of 11 s Streams value 14 4 I/O Requests Outstanding 12.5% of 11 s Streams value 15 4 I/O Requests Outstanding single (1) Stream Sequence I/O Request Outstanding maximum number of Streams 17 1 I/O Request Outstanding 50% of 16 s Streams value 18 1 I/O Request Outstanding 25% of 16 s Streams value 19 1 I/O Request Outstanding 12.5% of 16 s Streams value 20 1 I/O Request Outstanding single (1) Stream Video on Demand Delivery Test Video on Demand Delivery

29 SPC-2 TEST EXECUTION RESULTS Page 29 of 110 SPC-2 TESTS, TEST PHASES, TEST RUN SEQUENCES, AND TEST RUNS Each Test is an atomic unit that must be executed from start to finish before any other Test, Test Phase, or may be executed. The Tests may be executed in any sequence. The results from each Test, Test Phase, and are listed below along with a more detailed explanation of each component.

30 SPC-2 TEST EXECUTION RESULTS Page 30 of 110 LARGE FILE PROCESSING TEST Large File Processing Test Clause The Large File Processing Test consists of the I/O operations associated with the type of applications, in a wide range of fields, which require simple sequential processing of one or more large files. Specific examples of those types of applications include scientific computing and large-scale financial processing Clause The Large File Processing Test has three Test Phases, which shall be executed in the following uninterrupted sequence: 1. WRITE ONLY 2. READ-WRITE 3. READ ONLY The BC shall not be restarted or manually disturbed, altered, or adjusted during the execution of the Large File Processing Test. If power is lost to the BC during this Test all results shall be rendered invalid and the Test re-run in its entirety. Clause The Full Disclosure Report will contain the following content for the Large File Processing Test: 1. A listing of the SPC-2 Workload Generator commands and parameters used to execute each of the s in the Large File Processing Test. 2. The human readable SPC-2 Test Results File for each of the s in the Large File Processing Test. 3. The following three tables: Average : The average, in MB per second for the Measurement Interval of each in the Large File Processing Test. Average per Stream: The average per Stream, in MB per second, for the Measurement Interval of each in the Large File Processing Test. Average Response Time: The average response time, in milliseconds (ms), for the Measurement Interval of each in the Large File Processing Test. 4. Average, Average per Stream and Average Response Time graphs as defined in Clauses , and SPC-2 Workload Generator Commands and Parameters The SPC-2 Workload Generator commands and parameters for the Large File Processing s are documented in Appendix E: SPC-2 Workload Generator Execution Commands and Parameters on Page 109.

31 SPC-2 TEST EXECUTION RESULTS Page 31 of 110 LARGE FILE PROCESSING TEST SPC-2 Test Results File A link to the SPC-2 Test Results file generated from the Large File Processing s is listed below. SPC-2 Large File Processing Test Results File SPC-2 Large File Processing Average s (MB/s) The average (MB/s) for each in the three Test Phases of the SPC-2 Large File Processing Test is listed in the table below as well as illustrated in the following graph. Sequence 1 Stream 9 Streams 18 Streams 36 Streams 72 Streams Write 1024KiB , , , , Write 256KiB , , , , Read/Write 1024KiB , , , , Read/Write 256KiB , , , , Read 1024KiB , , , , Read 256KiB , , , ,895.52

32 SPC-2 TEST EXECUTION RESULTS Page 32 of 110 LARGE FILE PROCESSING TEST SPC-2 Large File Processing Average s Graph Large File Processing - 72 Streams, 6, MB/s 1024KiB transfers with only Write operations 36 Streams, 5, MB/s 18 Streams, 3, MB/s 9 Streams, 2, MB/s 1 Stream, MB/s 72 Streams, 6, MB/s 256KiB transfers with only Write operations 36 Streams, 4, MB/s 18 Streams, 3, MB/s 9 Streams, 1, MB/s 1 Stream, MB/s 1024KiB transfers with 50% Read operations 50% Write operations 72 Streams, 10, MB/s 36 Streams, 8, MB/s 18 Streams, 5, MB/s 9 Streams, 2, MB/s 1 Stream, MB/s 256KiB transfers with 50% Read operations 50% Write operations 72 Streams, 9, MB/s 36 Streams, 7, MB/s 18 Streams, 4, MB/s 9 Streams, 2, MB/s 1 Stream, MB/s 1024KiB transfers with only Read operations 1 Stream, MB/s 72 Streams, 12, MB/s 36 Streams, 11, MB/s 18 Streams, 8, MB/s 9 Streams, 4, MB/s 72 Streams, 11, MB/s 256KiB transfers with only Read operations 1 Stream, MB/s 18 Streams, 7, MB/s 9 Streams, 4, MB/s 36 Streams, 10, MB/s 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000, MB/sec

33 SPC-2 TEST EXECUTION RESULTS Page 33 of 110 LARGE FILE PROCESSING TEST SPC-2 Large File Processing Average per Stream The average per Stream for each in the three Test Phases of the SPC-2 Large File Processing Test is listed in the table below as well as illustrated in the following graph. Sequence 1 Stream 9 Streams 18 Streams 36 Streams 72 Streams Write 1024KiB Write 256KiB Read/Write 1024KiB Read/Write 256KiB Read 1024KiB Read 256KiB

34 SPC-2 TEST EXECUTION RESULTS Page 34 of 110 LARGE FILE PROCESSING TEST SPC-2 Large File Processing Average per Stream Graph Large File Processing - per Stream 72 Streams, MB/s 1024KiB transfers with only Write operations 36 Streams, MB/s 18 Streams, MB/s 9 Streams, MB/s 1 Stream, MB/s 72 Streams, MB/s 256KiB transfers with only Write operations 36 Streams, MB/s 18 Streams, MB/s 9 Streams, MB/s 1 Stream, MB/s 1024KiB transfers with 50% Read operations 50% Write operations 72 Streams, MB/s 36 Streams, MB/s 18 Streams, MB/s 9 Streams, MB/s 1 Stream, MB/s 256KiB transfers with 50% Read operations 50% Write operations 72 Streams, MB/s 36 Streams, MB/s 18 Streams, MB/s 9 Streams, MB/s 1 Stream, MB/s 1024KiB transfers with only Read operations 72 Streams, MB/s 36 Streams, MB/s 18 Streams, MB/s 9 Streams, MB/s 1 Stream, MB/s 256KiB transfers with only Read operations 72 Streams, MB/s 36 Streams, MB/s 18 Streams, MB/s 9 Streams, MB/s 1 Stream, MB/s , MB/sec

35 SPC-2 TEST EXECUTION RESULTS Page 35 of 110 LARGE FILE PROCESSING TEST SPC-2 Large File Processing Average Response Time The average Response Time, milliseconds (ms), for each in the three Test Phases of the SPC-2 Large File Processing Test is listed in the table below as well as illustrated in the following graph. Sequence 1 Stream 9 Streams 18 Streams 36 Streams 72 Streams Write 1024KiB Write 256KiB Read/Write 1024KiB Read/Write 256KiB Read 1024KiB Read 256KiB

36 SPC-2 TEST EXECUTION RESULTS Page 36 of 110 LARGE FILE PROCESSING TEST SPC-2 Large File Processing Average Response Time Graph Large File Processing - Average Response Time 72 Streams, ms 1024KiB transfers with only Write operations 36 Streams, 6.70 ms 18 Streams, 4.96 ms 9 Streams, 4.64 ms 1 Stream, 4.49 ms 72 Streams, 3.13 ms 256KiB transfers with only Write operations 36 Streams, 1.92 ms 18 Streams, 1.53 ms 9 Streams, 1.59 ms 1 Stream, 1.58 ms 1024KiB transfers with 50% Read operations 50% Write operations 72 Streams, 7.25 ms 36 Streams, 4.29 ms 18 Streams, 3.48 ms 9 Streams, 3.35 ms 1 Stream, 3.27 ms 256KiB transfers with 50% Read operations 50% Write operations 72 Streams, 1.95 ms 36 Streams, 1.24 ms 18 Streams, 1.08 ms 9 Streams, 1.09 ms 1 Stream, 1.06 ms 72 Streams, 6.24 ms 1024KiB transfers with only Read operations 36 Streams, 3.39 ms 18 Streams, 2.29 ms 9 Streams, 2.16 ms 1 Stream, 2.07 ms 72 Streams, 1.59 ms 256KiB transfers with only Read operations 36 Streams, 0.86 ms 18 Streams, 0.60 ms 9 Streams, 0.59 ms 1 Stream, 0.56 ms Response Time, ms

37 SPC-2 TEST EXECUTION RESULTS Page 37 of 110 LARGE FILE PROCESSING TEST WRITE ONLY TEST PHASE Large File Processing Test WRITE ONLY Test Phase Clause A table that will contain the following information for each WRITE ONLY, 1024 KiB Transfer Size : The number of Streams specified. The Average, Average per Stream, and Average Response Time reported at five second intervals. 2. Average by Intervals, Average per Stream by Intervals, and Average Response Time by Intervals graphs for the WRITE ONLY, 1024 KiB Transfer Size s as specified in Clauses A table that will contain the following information for each WRITE ONLY, 256 KiB Transfer Size : The number of Streams specified. The Average, Average per Stream, and Average Response Time reported at five second intervals. 4. Average by Intervals, Average per Stream by Intervals, and Average Response Time by Intervals graphs for the WRITE ONLY, 256 KiB Transfer Size s as specified in Clauses The SPC-2 Large File Processing/WRITE ONLY/1024 KiB Transfer Size data is contained in the table that appears on the next page. That table is followed by graphs illustrating the average, average per Stream, and average Response Time produced by the same s. The table and graphs present the data at fivesecond intervals. Immediately following the SPC-2 Large File Processing/WRITE ONLY/1024 KiB Transfer Size table and graphs will be the SPC-2 Large File Processing/WRITE ONLY/64 KiB Transfer Size table and graphs. The table contains the data and the graphs illustrate the average, average per Stream, and average Response Time produced by the s.

38 SPC-2 TEST EXECUTION RESULTS Page 38 of 110 LARGE FILE PROCESSING TEST WRITE ONLY TEST PHASE SPC-2 Large File Processing/WRITE ONLY/1024 KiB Transfer Size Data Ramp-Up Period TR1 72 Streams TR2 36 Streams TR3 18 Streams TR4 9 Streams TR5 1 Stream Sequence, / Stream, Response Sequence, / Stream, Response Sequence, / Stream, Response Sequence, / Stream, Response Sequence, / Stream, Time MB/sec MB/sec Time, ms Time MB/sec MB/sec Time, ms Time MB/sec MB/sec Time, ms Time MB/sec MB/sec Time, ms Time MB/sec MB/sec 0:00: :06: :13: :20: :27: :00:05 2, :07: :14: :21: :28: :00:10 2, :07:05 2, :14:05 1, :21: :28: :00:15 3, :07:10 3, :14:10 1, :21: :28: :00:20 4, :07:15 3, :14:15 1, :21: :28: :00:25 4, :07:20 3, :14:20 2, :21: :28: :00:30 5, :07:25 4, :14:25 2, :21: :28: :00:35 5, :07:30 4, :14:30 2, :21: :28: :00:40 5, :07:35 4, :14:35 2, :21: :28: :00:45 5, :07:40 4, :14:40 2, :21:40 1, :28: :00:50 5, :07:45 5, :14:45 2, :21:45 1, :28: :00:55 6, :07:50 5, :14:50 2, :21:50 1, :28: :01:00 6, :07:55 5, :14:55 2, :21:55 1, :28: :01:05 6, :08:00 5, :15:00 2, :22:00 1, :29: :01:10 6, :08:05 5, :15:05 3, :22:05 1, :29: :01:15 6, :08:10 5, :15:10 3, :22:10 1, :29: :01:20 6, :08:15 5, :15:15 3, :22:15 1, :29: :01:25 6, :08:20 5, :15:20 3, :22:20 1, :29: :01:30 6, :08:25 5, :15:25 3, :22:25 2, :29: :01:35 6, :08:30 5, :15:30 3, :22:30 2, :29: :01:40 6, :08:35 5, :15:35 3, :22:35 2, :29: :01:45 6, :08:40 5, :15:40 3, :22:40 2, :29: :01:50 6, :08:45 5, :15:45 3, :22:45 2, :29: :01:55 6, :08:50 5, :15:50 3, :22:50 2, :29: :02:00 6, :08:55 5, :15:55 3, :22:55 2, :29: :02:05 6, :09:00 5, :16:00 3, :23:00 2, :30: :02:10 6, :09:05 5, :16:05 3, :23:05 2, :30: :02:15 6, :09:10 5, :16:10 3, :23:10 2, :30: :02:20 6, :09:15 5, :16:15 3, :23:15 2, :30: :02:25 6, :09:20 5, :16:20 3, :23:20 2, :30: :02:30 6, :09:25 5, :16:25 3, :23:25 2, :30: :02:35 6, :09:30 5, :16:30 3, :23:30 2, :30: :02:40 6, :09:35 5, :16:35 3, :23:35 2, :30: :02:45 6, :09:40 5, :16:40 3, :23:40 2, :30: :02:50 6, :09:45 5, :16:45 3, :23:45 2, :30: :02:55 6, :09:50 5, :16:50 3, :23:50 2, :30: :09:55 5, :16:55 3, :23:55 2, :30: Response Time, ms

SPC BENCHMARK 2 FULL DISCLOSURE REPORT VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018

SPC BENCHMARK 2 FULL DISCLOSURE REPORT VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018 SPC BENCHMARK 2 FULL DISCLOSURE REPORT VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018 SUBMISSION IDENTIFIER: B12004 PREAMBLE ii First Edition August 2018

More information

SPC BENCHMARK 2 FULL DISCLOSURE REPORT HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE VM SPC-2 V1.5

SPC BENCHMARK 2 FULL DISCLOSURE REPORT HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE VM SPC-2 V1.5 SPC BENCHMARK 2 FULL DISCLOSURE REPORT HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE VM SPC-2 V1.5 Submitted for Review: January 21, 2014 First Edition January 2014 THE INFORMATION CONTAINED

More information

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM STORWIZE V3700 (TURBO) SPC-1 V1.14

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM STORWIZE V3700 (TURBO) SPC-1 V1.14 SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM STORWIZE V3700 (TURBO) SPC-1 V1.14 Submitted for Review: April 18, 2014 Submission Identifier: A00143 ii First Edition April 2014 THE INFORMATION

More information

SPC BENCHMARK 1C FULL DISCLOSURE REPORT ORACLE CORPORATION SUN STORAGE F5100 FLASH ARRAY SPC-1C V1.3

SPC BENCHMARK 1C FULL DISCLOSURE REPORT ORACLE CORPORATION SUN STORAGE F5100 FLASH ARRAY SPC-1C V1.3 SPC BENCHMARK 1C FULL DISCLOSURE REPORT ORACLE CORPORATION SUN STORAGE F5100 FLASH ARRAY SPC-1C V1.3 Submitted for Review: April 13, 2010 Submission Identifier: C00010 ii First Edition April 2010 THE INFORMATION

More information

SPC BENCHMARK 2 EXECUTIVE SUMMARY EMC CORPORATION EMC VMAX 400K SPC-2 V1.5. Submitted for Review: July 30, 2015 Submission Identifier: B00073

SPC BENCHMARK 2 EXECUTIVE SUMMARY EMC CORPORATION EMC VMAX 400K SPC-2 V1.5. Submitted for Review: July 30, 2015 Submission Identifier: B00073 SPC BENCHMARK 2 EXECUTIVE SUMMARY EMC CORPORATION SPC-2 V1.5 Submitted for Review: July 30, 2015 EXECUTIVE SUMMARY Page 2 of 11 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor Primary

More information

SPC BENCHMARK 2 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX8700 S2 SPC-2 V1.4

SPC BENCHMARK 2 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX8700 S2 SPC-2 V1.4 SPC BENCHMARK 2 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX8700 S2 SPC-2 V1.4 Submitted for Review: December 3, 2012 EXECUTIVE SUMMARY Page 2 of 9 EXECUTIVE SUMMARY Test Sponsor

More information

SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM XIV STORAGE SYSTEM GEN3 SPC-2/E V1.4

SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM XIV STORAGE SYSTEM GEN3 SPC-2/E V1.4 SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM XIV STORAGE SYSTEM GEN3 SPC-2/E V1.4 Submitted for Review: October 19, 2011 EXECUTIVE SUMMARY Page 2 of 9 EXECUTIVE SUMMARY Test Sponsor and

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY

SPC BENCHMARK 1 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY NETAPP, INC. NETAPP EF560 STORAGE SYSTEM SPC-1 V1.14 Submitted for Review: January 27, 2015 Submission Identifier: A00152 EXECUTIVE SUMMARY Page 2 of 9 EXECUTIVE SUMMARY

More information

SPC BENCHMARK 1 FULL DISCLOSURE REPORT DATACORE SOFTWARE CORPORATION DATACORE SANSYMPHONY-V 10.0 SPC-1 V1.14

SPC BENCHMARK 1 FULL DISCLOSURE REPORT DATACORE SOFTWARE CORPORATION DATACORE SANSYMPHONY-V 10.0 SPC-1 V1.14 SPC BENCHMARK 1 FULL DISCLOSURE REPORT DATACORE SOFTWARE CORPORATION DATACORE SANSYMPHONY-V 10.0 SPC-1 V1.14 Submitted for Review: November 30, 2015 Submission Identifier: A00164 ii First Edition November

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS3524 EXPRESS SPC-1 V1.12

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS3524 EXPRESS SPC-1 V1.12 SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS3524 EXPRESS SPC-1 V1.12 Submitted for Review: December 31, 2010 Submission Identifier: A00101 EXECUTIVE SUMMARY Page 2 of 7 EXECUTIVE

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 (SSDS) SPC-1 V1.12

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 (SSDS) SPC-1 V1.12 SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 (SSDS) SPC-1 V1.12 Submitted for Review: June 4, 2012 Submission Identifier: A00116 EXECUTIVE SUMMARY Page 2 of 8 EXECUTIVE SUMMARY

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM POWER 780 SERVER (WITH SSDS) SPC-1 V1.13

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM POWER 780 SERVER (WITH SSDS) SPC-1 V1.13 SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM POWER 780 SERVER (WITH SSDS) SPC-1 V1.13 Submitted for Review: April 11, 2013 Submission Identifier: A00130 EXECUTIVE SUMMARY Page 2 of 9 EXECUTIVE

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASYTIER AND SSDS) SPC-1 V1.12

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASYTIER AND SSDS) SPC-1 V1.12 SPC BENCHMARK EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS87 RELEASE. (EASYTIER AND SSDS) SPC- V. Submitted for Review: April, Submission Identifier: A9 EXECUTIVE SUMMARY Page of 8 EXECUTIVE

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX200 S3 SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX200 S3 SPC-1 V1.14 SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX200 S3 SPC-1 V1.14 Submitted for Review: December 30, 2013 Submission Identifier: A00139 EXECUTIVE SUMMARY Page 2 of

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY PILLAR DATA SYSTEMS,INC. PILLAR AXIOM 600 SPC-1 V1.10.1

SPC BENCHMARK 1 EXECUTIVE SUMMARY PILLAR DATA SYSTEMS,INC. PILLAR AXIOM 600 SPC-1 V1.10.1 SPC BENCHMARK 1 EXECUTIVE SUMMARY PILLAR DATA SYSTEMS,INC. PILLAR AXIOM 600 SPC-1 V1.10.1 Submitted for Review: January 13, 2009 Submission Identifier: A00073 EXECUTIVE SUMMARY Page 2 of 6 EXECUTIVE SUMMARY

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14 SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14 Submitted for Review: April 26, 2016 Submission Identifier: A00174 EXECUTIVE SUMMARY Page 2 of 12 EXECUTIVE

More information

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DE6000H SPC-1 V3.8 SUBMISSION IDENTIFIER: A32008

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DE6000H SPC-1 V3.8 SUBMISSION IDENTIFIER: A32008 SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DE6000H SPC-1 V3.8 SUBMISSION IDENTIFIER: A32008 SUBMITTED FOR REVIEW: NOVEMBER 9, 2018 PREAMBLE Page 2 of 49 First Edition November 2018 THE INFORMATION

More information

SPC BENCHMARK 1 FULL DISCLOSURE REPORT FUJITSU LIMITED ETERNUS AF650 S2 SPC-1 V3.5.0 SUBMISSION IDENTIFIER: A32004

SPC BENCHMARK 1 FULL DISCLOSURE REPORT FUJITSU LIMITED ETERNUS AF650 S2 SPC-1 V3.5.0 SUBMISSION IDENTIFIER: A32004 SPC BENCHMARK 1 FULL DISCLOSURE REPORT FUJITSU LIMITED ETERNUS AF650 S2 SPC-1 V3.5.0 SUBMISSION IDENTIFIER: A32004 SUBMITTED FOR REVIEW: JANUARY 19, 2018 PREAMBLE Page 2 of 35 First Edition January 2018

More information

LENOVO THINKSYSTEM DE6000H

LENOVO THINKSYSTEM DE6000H EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY LENOVO THINKSYSTEM DE6000H SPC-1 IOPS 460,011 SPC-1 Price-Performance $91.76/SPC-1 KIOPS SPC-1 IOPS Response Time SPC-1 Overall Response Time SPC-1 ASU

More information

FUJITSU LIMITED ETERNUS AF250 S2

FUJITSU LIMITED ETERNUS AF250 S2 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED ETERNUS AF250 S2 SPC-1 IOPS 360,070 SPC-1 Price-Performance $94.02/SPC-1 KIOPS SPC-1 IOPS Response Time SPC-1 Overall Response Time SPC-1

More information

High-Performance Lustre with Maximum Data Assurance

High-Performance Lustre with Maximum Data Assurance High-Performance Lustre with Maximum Data Assurance Silicon Graphics International Corp. 900 North McCarthy Blvd. Milpitas, CA 95035 Disclaimer and Copyright Notice The information presented here is meant

More information

HP SAS benchmark performance tests

HP SAS benchmark performance tests HP SAS benchmark performance tests technology brief Abstract... 2 Introduction... 2 Test hardware... 2 HP ProLiant DL585 server... 2 HP ProLiant DL380 G4 and G4 SAS servers... 3 HP Smart Array P600 SAS

More information

SPC BENCHMARK 2 EXECUTIVE SUMMARY VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018

SPC BENCHMARK 2 EXECUTIVE SUMMARY VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018 SPC BENCHMARK 2 EXECUTIVE SUMMARY VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018 SUBMISSION IDENTIFIER: B12004 EXECUTIVE SUMMARY Page 2 f 9 EXECUTIVE SUMMARY

More information

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Best practices Roland Mueller IBM Systems and Technology Group ISV Enablement April 2012 Copyright IBM Corporation, 2012

More information

Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution

Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution Technical Report Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution Joel W. King, NetApp September 2012 TR-4110 TABLE OF CONTENTS 1 Executive Summary... 3 1.1 Overview...

More information

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing EMC VMAX 400K SPC-2 Proven Performance Silverton Consulting, Inc. StorInt Briefing EMC VMAX 400K SPC-2 PROVEN PERFORMANCE PAGE 2 OF 10 Introduction In this paper, we analyze all- flash EMC VMAX 400K storage

More information

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Evaluation report prepared under contract with LSI Corporation Introduction IT professionals see Solid State Disk (SSD) products as

More information

Sun Fire X4170 M2 Server Frequently Asked Questions

Sun Fire X4170 M2 Server Frequently Asked Questions Overview Faced with ever increasing computing needs and budget constraints, companies today want to set up infrastructures that offer optimal value, can easily be re-purposed, and have reduced complexity.

More information

Hewlett-Packard Enterprise Company

Hewlett-Packard Enterprise Company Hewlett-Packard Enterprise Company TPC Benchmark H Full Disclosure Report for Hewlett Packard Enterprise ProLiant DL580 Gen9 using and Red Hat Enterprise Linux Server 7.2 Edition First Edition i Hewlett-Packard

More information

How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity

How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity 9-November-2010 Singapore How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity Shiva Anand Neiker Storage Sales Leader STG ASEAN How Smarter Systems Deliver Smarter Economics

More information

SGI DataRaptor Appliance with MarkLogic Database. Quick Start Guide

SGI DataRaptor Appliance with MarkLogic Database. Quick Start Guide SGI DataRaptor Appliance with MarkLogic Database Quick Start Guide 007-5907-001 COPYRIGHT 2013 Silicon Graphics International Corp. All rights reserved; provided portions may be copyright in third parties,

More information

TELECOMMUNICATIONS TECHNOLOGY ASSOCIATION JET-SPEED HHS3124F / HHS2112F (10 NODES)

TELECOMMUNICATIONS TECHNOLOGY ASSOCIATION JET-SPEED HHS3124F / HHS2112F (10 NODES) EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY TELECOMMUNICATIONS TECHNOLOGY ASSOCIATION JET-SPEED HHS3124F / HHS2112F (10 NODES) SPC-1 IOPS 2,410,271 SPC-1 Price-Performance $287.01/SPC-1 KIOPS SPC-1

More information

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740 Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740 A performance study of 14 th generation Dell EMC PowerEdge servers for Microsoft SQL Server Dell EMC Engineering September

More information

STORAGE. EVOLVED. PRODUCT guide

STORAGE. EVOLVED. PRODUCT guide STORAGE. EVOLVED. PRODUCT guide Mac Storage Solutions designed for the pros -- and perfect for you! G-Technology offers premium external storage solutions for content creators. Our complete portfolio delivers

More information

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March IOmark- VM HP MSA P2000 Test Report: VM- 140304-2a Test Report Date: 4, March 2014 Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VM, IOmark- VDI, VDI- IOmark, and IOmark are trademarks

More information

SAS workload performance improvements with IBM XIV Storage System Gen3

SAS workload performance improvements with IBM XIV Storage System Gen3 SAS workload performance improvements with IBM XIV Storage System Gen3 Including performance comparison with XIV second-generation model Narayana Pattipati IBM Systems and Technology Group ISV Enablement

More information

TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage

TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage Performance Study of Microsoft SQL Server 2016 Dell Engineering February 2017 Table of contents

More information

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades Evaluation report prepared under contract with Dot Hill August 2015 Executive Summary Solid state

More information

IBM System p5 570 POWER5+ processor and memory features offer new options

IBM System p5 570 POWER5+ processor and memory features offer new options Hardware Announcement February 14, 2006 IBM System p5 570 POWER5+ processor and memory features offer new options Overview The System p5 570 offers new POWER5+ processor options with 64-bit 1.9 GHz and

More information

IBM TotalStorage 2104 Expandable Storage Plus 320 offers new high-performance disk drive capacity

IBM TotalStorage 2104 Expandable Storage Plus 320 offers new high-performance disk drive capacity Hardware Announcement April 19, 2005 IBM TotalStorage 2104 Expandable Storage Plus 320 offers new high-performance disk drive capacity Overview The IBM TotalStorage Exp Plus 320 now offers the option of

More information

IBM p5 520 and way and 2-way 1.5 GHz processors offer new processor speed options

IBM p5 520 and way and 2-way 1.5 GHz processors offer new processor speed options Hardware Announcement October 5, 2004 IBM p5 520 and 550 1-way and 2-way 1.5 GHz processors offer new processor speed options Overview IBM p5 520 and 550 offer new POWER5 processor options with the optional

More information

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DS4200 SPC-1 V3.4.0 SUBMISSION IDENTIFIER: A32002

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DS4200 SPC-1 V3.4.0 SUBMISSION IDENTIFIER: A32002 SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DS4200 SPC-1 V3.4.0 SUBMISSION IDENTIFIER: A32002 SUBMITTED FOR REVIEW: JULY 19, 2017 PRE AMBLE Page 2 of 40 First Edition July 2017 THE INFORMATION

More information

HPE ProLiant ML110 Gen10 Server

HPE ProLiant ML110 Gen10 Server Digital data sheet HPE ProLiant ML110 Gen10 Server ProLiant ML Servers What's new New SMB focused offers regionally released as Smart Buy Express in the U.S. and Canada, Top Value in Europe, and Intelligent

More information

Microsoft SQL Server 2012 Fast Track Reference Architecture Using PowerEdge R720 and Compellent SC8000

Microsoft SQL Server 2012 Fast Track Reference Architecture Using PowerEdge R720 and Compellent SC8000 Microsoft SQL Server 2012 Fast Track Reference Architecture Using PowerEdge R720 and Compellent SC8000 This whitepaper describes the Dell Microsoft SQL Server Fast Track reference architecture configuration

More information

HPE ProLiant ML110 Gen P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P )

HPE ProLiant ML110 Gen P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P ) Digital data sheet HPE ProLiant ML110 Gen10 3104 1P 8GB-R S100i 4LFF NHP SATA 350W PS DVD Entry Server/TV (P03684-425) ProLiant ML Servers What's new New SMB focused offers regionally released as Smart

More information

MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS3000G2

MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS3000G2 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS3000G2 SPC-1 IOPS 430,020 SPC-1 Price-Performance $324.38/SPC-1 KIOPS SPC-1 IOPS Response Time 0.444 ms SPC-1

More information

An Oracle Technical White Paper October Sizing Guide for Single Click Configurations of Oracle s MySQL on Sun Fire x86 Servers

An Oracle Technical White Paper October Sizing Guide for Single Click Configurations of Oracle s MySQL on Sun Fire x86 Servers An Oracle Technical White Paper October 2011 Sizing Guide for Single Click Configurations of Oracle s MySQL on Sun Fire x86 Servers Introduction... 1 Foundation for an Enterprise Infrastructure... 2 Sun

More information

IBM System Storage DCS3700

IBM System Storage DCS3700 IBM System Storage DCS3700 Maximize performance, scalability and storage density at an affordable price Highlights Gain fast, highly dense storage capabilities at an affordable price Deliver simplified

More information

Infor M3 on IBM POWER7+ and using Solid State Drives

Infor M3 on IBM POWER7+ and using Solid State Drives Infor M3 on IBM POWER7+ and using Solid State Drives IBM Systems & Technology Group Robert Driesch cooter@us.ibm.com This document can be found on the web, Version Date: January 31, 2014 Table of Contents

More information

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview Overview HP offers a variety of tested, HP-qualified, SMART* capable, SATA Hard Drives offering data integrity and availability in hotpluggable models. HP 3.5" and Small Form Factor (2.5") SATA drives

More information

Technical Information. Experion eserver Specification EP Release July 2018, Version 1

Technical Information. Experion eserver Specification EP Release July 2018, Version 1 Technical Information Experion eserver Specification EP03-230-510 Release 510 6 July 2018, Version 1 Experion eserver Specification, EP03-230-510 2 Revision History Revision Date Description 1 6 July 2018

More information

1 I g-technology.com. PRODUCT guide

1 I g-technology.com. PRODUCT guide 1 I g-technology.com PRODUCT guide Storage solutions designed specifically for content creators G-Technology offers premium external storage solutions for content creators. Our complete portfolio delivers

More information

SAP SD Benchmark with DB2 and Red Hat Enterprise Linux 5 on IBM System x3850 M2

SAP SD Benchmark with DB2 and Red Hat Enterprise Linux 5 on IBM System x3850 M2 SAP SD Benchmark using DB2 and Red Hat Enterprise Linux 5 on IBM System x3850 M2 Version 1.0 November 2008 SAP SD Benchmark with DB2 and Red Hat Enterprise Linux 5 on IBM System x3850 M2 1801 Varsity Drive

More information

IBM System Storage DS8870 Release R7.3 Performance Update

IBM System Storage DS8870 Release R7.3 Performance Update IBM System Storage DS8870 Release R7.3 Performance Update Enterprise Storage Performance Yan Xu Agenda Summary of DS8870 Hardware Changes I/O Performance of High Performance Flash Enclosure (HPFE) Easy

More information

2 to 4 Intel Xeon Processor E v3 Family CPUs. Up to 12 SFF Disk Drives for Appliance Model. Up to 6 TB of Main Memory (with GB LRDIMMs)

2 to 4 Intel Xeon Processor E v3 Family CPUs. Up to 12 SFF Disk Drives for Appliance Model. Up to 6 TB of Main Memory (with GB LRDIMMs) Based on Cisco UCS C460 M4 Rack Servers Solution Brief May 2015 With Intelligent Intel Xeon Processors Highlights Integrate with Your Existing Data Center Our SAP HANA appliances help you get up and running

More information

HPE ProLiant DL360 Gen P 16GB-R P408i-a 8SFF 500W PS Performance Server (P06453-B21)

HPE ProLiant DL360 Gen P 16GB-R P408i-a 8SFF 500W PS Performance Server (P06453-B21) Digital data sheet HPE ProLiant DL360 Gen10 4110 1P 16GB-R P408i-a 8SFF 500W PS Performance Server (P06453-B21) ProLiant DL Servers What's new Innovative design with greater flexibility to mix and match

More information

Introduction to IBM System Storage SVC 2145-DH8 and IBM Storwize V7000 model 524

Introduction to IBM System Storage SVC 2145-DH8 and IBM Storwize V7000 model 524 Introduction to IBM System Storage SVC 2145-DH8 and IBM Storwize V7000 model 524 Guide v1.0 Bhushan Gavankar, Sarvesh S. Patel IBM Systems and Technology Group June 2014 Copyright IBM Corporation, 2014

More information

SGI InfiniteStorage 350 Quick Start Guide

SGI InfiniteStorage 350 Quick Start Guide SGI InfiniteStorage 350 Quick Start Guide 007-4932-001 CONTRIBUTORS Written by Mark Schwenden Illustrated by Chrystie Danzer Production by Mark Schwenden Additional contributions by Dick Brownell, Cheryl

More information

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP All-flash configurations are designed to deliver maximum IOPS and throughput numbers for mission critical workloads and applicati

More information

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure Generational Comparison Study of Microsoft SQL Server Dell Engineering February 2017 Revisions Date Description February 2017 Version 1.0

More information

IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor

IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor IBM United States Announcement 107-099, dated February 14, 2007 IBM System p5 560Q boosts performance with new Quad-Core Module with 1.8 GHz POWER5+ processor Description...2 Publications... 4 Services...4

More information

HP ProLiant delivers #1 overall TPC-C price/performance result with the ML350 G6

HP ProLiant delivers #1 overall TPC-C price/performance result with the ML350 G6 HP ProLiant ML350 G6 sets new TPC-C price/performance record ProLiant ML350 continues its leadership for the small business HP Leadership with the ML350 G6» The industry s best selling x86 2-processor

More information

Empowering. Video Surveillance. Highly integrated. Simple to deploy. Vess A-Series & Vess R-Series

Empowering. Video Surveillance. Highly integrated. Simple to deploy. Vess A-Series & Vess R-Series Empowering Video Surveillance Highly integrated. Simple to deploy. Vess A-Series & Vess R-Series High Performance NVR Appliance and Storage Solutions for Video Surveillance The latest advances in video

More information

IOmark- VM. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VM- HC b Test Report Date: 27, April

IOmark- VM. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VM- HC b Test Report Date: 27, April IOmark- VM HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VM- HC- 150427- b Test Report Date: 27, April 2015 Copyright 2010-2015 Evaluator Group, Inc. All rights reserved. IOmark- VM, IOmark-

More information

Entry-level Intel RAID RS3 Controller Family

Entry-level Intel RAID RS3 Controller Family PRODUCT Brief Entry-Level Intel RAID RS3 Controller Portfolio Entry-level Intel RAID RS3 Controller Family 12Gb/s connectivity and basic data protection RAID matters. Rely on Intel RAID. Cost-effective

More information

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Introduction to NetApp E-Series E2700 with SANtricity 11.10 d Technical Report Introduction to NetApp E-Series E2700 with SANtricity 11.10 Todd Edwards, NetApp March 2014 TR-4275 1 Introduction to NetApp E-Series E2700 with SANtricity 11.10 TABLE OF CONTENTS 1

More information

vstart 50 VMware vsphere Solution Specification

vstart 50 VMware vsphere Solution Specification vstart 50 VMware vsphere Solution Specification Release 1.3 for 12 th Generation Servers Dell Virtualization Solutions Engineering Revision: A00 March 2012 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES

More information

Lenovo Database Configuration

Lenovo Database Configuration Lenovo Database Configuration for Microsoft SQL Server OLTP on Flex System with DS6200 Reduce time to value with pretested hardware configurations - 20TB Database and 3 Million TPM OLTP problem and a solution

More information

SGI Hadoop Based on Intel Xeon Processor E5 Family. Getting Started Guide

SGI Hadoop Based on Intel Xeon Processor E5 Family. Getting Started Guide SGI Hadoop Based on Intel Xeon Processor E5 Family Getting Started Guide 007-5875-001 COPYRIGHT 2013 Silicon Graphics International Corp. All rights reserved; provided portions may be copyright in third

More information

IBM Power 780 Server Model 9179-MHB Using AIX Version 6.1 and DB2 Enterprise 9.5. TPC Benchmark TM C Full Disclosure Report

IBM Power 780 Server Model 9179-MHB Using AIX Version 6.1 and DB2 Enterprise 9.5. TPC Benchmark TM C Full Disclosure Report IBM Power 780 Server Model 9179-MHB Using AIX Version 6.1 and DB2 Enterprise 9.5 TPC Benchmark TM C Full Disclosure Report Third Edition July 19, 2010 Special Notices The following terms used in this publication

More information

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family Modular Storage The Dell PowerVault MD Storage Family The affordable choice The Dell PowerVault MD family is an affordable choice for reliable storage. The new MD3 models improve connectivity and performance

More information

SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS2500G2-25E SPC-1 IOPS 300,028

SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS2500G2-25E SPC-1 IOPS 300,028 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS2500G2-25E SPC-1 IOPS 300,028 SPC-1 Price-Performance $379.50/SPC-1 KIOPS SPC-1 IOPS Response Time 0.480 ms

More information

IBM System Storage EXP3500 Express

IBM System Storage EXP3500 Express EXP3500 Express Low-cost, high-performance 6 Gbps SAS expansion units Highlights Provide a highly available storage system by supporting attachment to the IBM DS3500 Express storage system Support high

More information

60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020

60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020 Configuration and performance results Abstract This paper describes the design

More information

Milestone Solution Partner IT Infrastructure Components Certification Report

Milestone Solution Partner IT Infrastructure Components Certification Report Milestone Solution Partner IT Infrastructure Components Certification Report Dell Storage PS6610, Dell EqualLogic PS6210, Dell EqualLogic FS7610 July 2015 Revisions Date July 2015 Description Initial release

More information

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4 W H I T E P A P E R Comparison of Storage Protocol Performance in VMware vsphere 4 Table of Contents Introduction................................................................... 3 Executive Summary............................................................

More information

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR V3

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR V3 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 18500 V3 SPC-1 IOPS 2,340,241 SPC-1 Price-Performance $549.75/SPC-1 KIOPS SPC-1 IOPS Response Time 0.723

More information

IBM System p5 550 and 550Q Express servers

IBM System p5 550 and 550Q Express servers The right solutions for consolidating multiple applications on a single system IBM System p5 550 and 550Q Express servers Highlights Up to 8-core scalability using Quad-Core Module technology Point, click

More information

Extremely Fast Distributed Storage for Cloud Service Providers

Extremely Fast Distributed Storage for Cloud Service Providers Solution brief Intel Storage Builders StorPool Storage Intel SSD DC S3510 Series Intel Xeon Processor E3 and E5 Families Intel Ethernet Converged Network Adapter X710 Family Extremely Fast Distributed

More information

HP ProLiant DL580 G5. HP ProLiant BL680c G5. IBM p570 POWER6. Fujitsu Siemens PRIMERGY RX600 S4. Egenera BladeFrame PB400003R.

HP ProLiant DL580 G5. HP ProLiant BL680c G5. IBM p570 POWER6. Fujitsu Siemens PRIMERGY RX600 S4. Egenera BladeFrame PB400003R. HP ProLiant DL58 G5 earns #1 overall four-processor performance; ProLiant BL68c takes #2 four-processor performance on Windows in two-tier SAP Sales and Distribution Standard Application Benchmark HP leadership

More information

HPE ProLiant ML350 Gen10 Server

HPE ProLiant ML350 Gen10 Server Digital data sheet HPE ProLiant ML350 Gen10 Server ProLiant ML Servers What's new Support for Intel Xeon Scalable processors full stack. 2600 MT/s HPE DDR4 SmartMemory RDIMM/LRDIMM offering 8, 16, 32,

More information

SPC BENCHMARK 1 INSPUR ELECTRONIC INFORMATION INDUSTRY CO. LTD. INSPUR AS5500G2 EXECUTIVE SUMMARY SPC-1 IOPS 1,500,346

SPC BENCHMARK 1 INSPUR ELECTRONIC INFORMATION INDUSTRY CO. LTD. INSPUR AS5500G2 EXECUTIVE SUMMARY SPC-1 IOPS 1,500,346 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY INSPUR ELECTRONIC INFORMATION INDUSTRY CO. LTD. INSPUR AS5500G2 SPC-1 IOPS 1,500,346 SPC-1 Price-Performance $307.62/SPC-1 KIOPS SPC-1 IOPS Response

More information

NotesBench Disclosure Report for IBM Netfinity 3500 (RAID-5) with Lotus Domino Server 4.6a for Windows NT 4.0

NotesBench Disclosure Report for IBM Netfinity 3500 (RAID-5) with Lotus Domino Server 4.6a for Windows NT 4.0 UNITED STATES NotesBench Disclosure Report for IBM Netfinity 3500 (RAID-5) with Lotus Domino Server 4.6a for Windows NT 4.0 Audited May 8, 1998 IBM Corporation UNITED STATES Table of Contents Executive

More information

Key results at a glance:

Key results at a glance: HP ProLiant BL680c G5 server blade takes world record for excellent performance for four-processor server on three-tier SAP SD Standard Application Benchmark with Microsoft Windows 2008. The HP Difference

More information

Create a Flexible, Scalable High-Performance Storage Cluster with WekaIO Matrix

Create a Flexible, Scalable High-Performance Storage Cluster with WekaIO Matrix Solution brief Intel Storage Builders WekaIO Matrix Intel eon Processor E5-2600 Product Family Intel Ethernet Converged Network Adapter 520 Intel SSD Data Center Family Data Plane Development Kit Create

More information

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers By Todd Muirhead Dell Enterprise Technology Center Dell Enterprise Technology Center dell.com/techcenter

More information

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR DORADO5000 V3

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR DORADO5000 V3 EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR DORADO5000 V3 SPC-1 IOPS 800,465 SPC-1 Price-Performance $0.48/SPC-1 IOPS SPC-1 IOPS Response Time 0.507

More information

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage A Dell Technical White Paper Dell Database Engineering Solutions Anthony Fernandez April 2010 THIS

More information

Milestone Solution Partner IT Infrastructure Components Certification Report

Milestone Solution Partner IT Infrastructure Components Certification Report Milestone Solution Partner IT Infrastructure Components Certification Report Huawei OceanStor 5500 V3 SAN Storage 08-09-2015 Table of Contents Executive Summary:... 4 Abstract... 4 Certified Products...

More information

HPE ProLiant ML350 Gen P 16GB-R E208i-a 8SFF 1x800W RPS Solution Server (P04674-S01)

HPE ProLiant ML350 Gen P 16GB-R E208i-a 8SFF 1x800W RPS Solution Server (P04674-S01) Digital data sheet HPE ProLiant ML350 Gen10 4110 1P 16GB-R E208i-a 8SFF 1x800W RPS Solution Server (P04674-S01) ProLiant ML Servers What's new Support for Intel Xeon Scalable processors full stack. 2600

More information

SanDisk Enterprise Storage Solutions

SanDisk Enterprise Storage Solutions SanDisk Enterprise Storage Solutions Mike Chenery Senior Fellow Deutsche Bank Technology Conference Las Vegas, Nevada September 14, 2011 Forward-looking Statement During our meeting today we will be making

More information

SUPERMICRO NEXENTASTOR 5.0 REFERENCE ARCHITECTURE

SUPERMICRO NEXENTASTOR 5.0 REFERENCE ARCHITECTURE REFERENCE ARCHITECTURE SUPERMICRO NEXENTASTOR 5.0 REFERENCE ARCHITECTURE TABLE OF CONTENTS 2 SUPERMICRO REFERENCE ARCHITECTURES SOLUTION Supermicro All-Flash Configurations 2 Supermicro X10 All-Flash 24

More information

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage By Dave Jaffe Dell Enterprise Technology Center and Kendra Matthews Dell Storage Marketing Group Dell Enterprise Technology Center delltechcenter.com

More information

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions A comparative analysis with PowerEdge R510 and PERC H700 Global Solutions Engineering Dell Product

More information

SanDisk Overview. Mike Chenery Senior Fellow. 5th Annual Needham HDD & Memory Conference Boston, MA. November 3, 2011

SanDisk Overview. Mike Chenery Senior Fellow. 5th Annual Needham HDD & Memory Conference Boston, MA. November 3, 2011 SanDisk Overview Mike Chenery Senior Fellow 5th Annual Needham HDD & Memory Conference Boston, MA November 3, 2011 Forward-looking Statement During our meeting today we will be making forward-looking statements.

More information

An Oracle White Paper. Released April 2013

An Oracle White Paper. Released April 2013 Performance and Scalability Benchmark: Siebel CRM Release 8.1.1.4 Industry Applications and Oracle 11.2.0.3 Database on Oracle's SPARC T5 Servers and Oracle Solaris An Oracle White Paper Released April

More information

TPC Benchmark H Full Disclosure Report. SPARC T4-4 Server Using Oracle Database 11g Release 2 Enterprise Edition with Partitioning

TPC Benchmark H Full Disclosure Report. SPARC T4-4 Server Using Oracle Database 11g Release 2 Enterprise Edition with Partitioning TPC Benchmark H Full Disclosure Report SPARC T4-4 Server Using Oracle Database 11g Release 2 Enterprise Edition with Partitioning Submitted for Review September 26, 2011 First Printing September 26, 2011

More information

Architecting Storage for Semiconductor Design: Manufacturing Preparation

Architecting Storage for Semiconductor Design: Manufacturing Preparation White Paper Architecting Storage for Semiconductor Design: Manufacturing Preparation March 2012 WP-7157 EXECUTIVE SUMMARY The manufacturing preparation phase of semiconductor design especially mask data

More information

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family Dell PowerVault MD Family Modular storage The Dell PowerVault MD storage family Dell PowerVault MD Family The affordable choice The Dell PowerVault MD family is an affordable choice for reliable storage.

More information

Cisco Connected Safety and Security UCS C220

Cisco Connected Safety and Security UCS C220 Data Sheet Cisco Connected Safety and Security UCS Platform Series The Cisco Connected Safety and Security (CSS) Unified Computing System (UCS ) Platform Series offers you performance and density for deploying

More information