OVAL FLOWMETER Meter Size: 34,65
|
|
- Beatrix Shields
- 6 years ago
- Views:
Transcription
1 OVAL FLOWMETER Meter Size:, ( Single Case Construction ) with Powerful Magnetic Coupling GENERAL SPECIFICATION GS.No.GBB8--E GENERAL The OVAL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear rotors. It is capable of metering the actual quantity of the material passing through it with a high degree of precision over a wide flow range and accepts any liquid irrespective of its chemical or physical properties. It s accuracy, reliability and quality has made it a highly valued industrial instrument. FEATURES. Simple design makes this meter easy to disassemble and allows for ease in maintenance and inspection.. Introduction of a powerful magnetic coupling makes this meter compatible with a variety of direct-reading registers.. Compatible with a variety of pulse generators that allows a wide selection of remote flow instrumentation.. Can accept liquids of widely varying chemical and physical properties by selecting appropriate meter materials.. A complete line of models are available to meet a broad range of pressure and temperature requirements. GENERAL SPECIFICATIONS Meter size: Meter size: Meter Size Item Nominal Size, mm (inch) Construction Transmission System Materials Linearity Repeatability Operating Temp. Range Liquids to be Metered Flow Direction Finish Rotors Bearings Linearity ±.% ±.% (") FC, SCSA, FC(w/surface treatment) Right Left (std.), Left Right, Bottom Top ( ), ( ) Single case construction Type Magnetic coupling* SCPH Carbon ±.% or ±.% ±.% or ±.% ~ + C ~ + C Petroleums Body, transmission gear box & register case: Munsell.G 8/ Frame: Munsell N. FC, FC(w/surface treatment) Right Left (std.), Left Right, Notes: *Refer to description in the model code number Flange Ratings and Max. Operating Pressures: MPa Pressure Rating K Outer Flange Rating JIS Flange Rating ANSI K K K K SCPH.8. K SCPH... NOTE: Reference temperature are C. SCPH.... OVAL Corporation Head Office: Tokyo; Tel Fax Beijing Office: Tel., Fax Tel Overseas Branch Offices: Seoul. Singapore. Taipei
2 FLOW RANGE Table A Flow Range for Liquid in General (Linearity : ±.%) (Operating temp. range:- ~ + C) Meter Size Bore, mm Operating Condition Type of Liquid Temp., Viscosity Range Continuous Intermittent A.I.F. ~ ~ Continuous ~ Intermittent ~ 8 A.I.F. Unit in m /h Liquids other than water Unite in mpa.s Less than.. ~.8.8 ~ ~ ~ ~ ~ 8 ~ 8 ~ ~ ~ 8 ~ ~ ~ ~ 8 ~ ~ 8 ~ 8 8 ~ ~ ~ ~ 8 ~ ~ 8 ~ ~ 8 ~ 8 8 ~ ~ ~ ~ 8 8 Table B Flow Range for Liquid in General (Linearity : ±.%) (Operating temp. range:- ~ + C) Meter Size Bore, mm Operating Condition NOTES:. In the Operating Condition column Continuous means continuous operation; Intermittent means no more than 8 hours operation a day, and A.I.F. indicates allowable instantaneous flow rate.. Flow range should be selected within the Continuous or Intermittent range specified.. For applications where viscosity exceeds mpa.s, specially machined rotors are used. REGISTERS AND UNIT REGISTRATION Model Dial and Pointer Total Counter Volume per Point Rev. (L) Min. Reading (L) Max. Readout (L) LSD Drum (L) Direct-reading (LW) Direct-reading w/reset Counter (LW) Resettable (LW, ) Type of Liquid Temp., Viscosity Range Continuous Intermittent A.I.F. ~ ~ Continuous ~ Intermittent ~ 8 A.I.F. Unit in m /h Liquids other than water Unite in mpa.s Less than.. ~.8.8 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 8 ~ 8 ~ 8 ~ ~ ~ 8 ~ ~ ~ ~ 8 ~ ~ 8 ~ ~ 8 ~ 8 8 ~ ~ ~ ~ 8 8 : Standard. As to general specifications registers, refer to individual General Specification Sheets. (LSD: Least Significant Digit) Unit of Factored Pulse Generated Unit of Unfactored Pulse Generation Volume per Pointer Rev. L/rev. Meter Size Genrator Pulse No. Signal Unit (L/P) P / rev. PG. PGS Freq. at Max. (Hz) (L/P) P / rev. Freq. at Max. (Hz) (L/P) P / rev. PG. PGD Freq. at Max. (Hz) P / rev. (L/P) Freq. at Max. (Hz) Max. m /h PGS Nominal Meter Factor (ml/p) Less than Full Scale (m /h) More than Full Scale (m /h) () () : Standard For detailed pulse generator specifications, see individual General Specification Sheets. 8 () 8 () Full Scale for Indicator or Recorder Meter Size Full Scale m /h 8 8 Full Scale L/min. 8
3 Oval Oval Oval Oval OVAL MODEL EL REGISTERS AND REMOTE INSTRUMENTATION SYSTEMS Direct-coupled s and Remote Instrumentation System with Pulse Generator Equipped Totalizer EL EL Batch Controller EL8 Batch Coontroller EL8 Series Blender EL Series Multiple Temp. Compensator EL Series 8 Digital Controller PG Pulse Generator (Contact-closure) PG, PGD, PGS, Voltage Pulse Generator LW 8 LW Factored Pulse Generation Basic Oval Flowmeter Unfactored Pulse Generation Convenient Type Accuracy Adjustor (AF) Fixed Type Accuracy Adjustor (AG) 8 PG S LW F/I Converter Converter/ Compensator LW SU SU EL8 Indicator EL Recorder Controller, Analog Instrument Direct-coupled s without Pulse Generator LW Registser 8 LW 8 LW, Basic Oval Flowmeter NOTES:. For details of the direct-coupled register, pulse generators, receiving instruments, etc., see individual General Sepcification Sheets.. Flameproof construction of pulse generators are available. For intrinsically safe construction, pulse repeater is provided.
4 TYPICAL PERFORMANCE CHARACTERISTICS Meter error, % +.. Pressure Drop, kpa Gasoline.mPa.s Kerosene.mPa.s Gas Oil mpa.s Fuel Oil mpa.s Meter Size Meter Size 8 8, m /h DIMENSIONS Meter Size Unit in mm (LW Installed) ;; D L a: F b:8 A R a: Transmission Gear Box w/external Accuracy Adjustor (GB- ) b: Transmission Gear Box w/built-in Accuracy Adjustor (GB-) No. Part Name Flange Oval Rotors Conversion Gear Ass y Mat l Symbol and Press. Rating F F * In case of cooling fin coupled, add mm to F above. F R D A a b Mass kg 8 8 Flange-to-Flange Dimensions (L) Meter Size Nom. size mm (") Flange ratings JIS K RF JIS K RF JIS K RF ANSI RF ANSI RF Pressure Rating K K Unit in mm
5 DIMENSIONS Meter Size (LW Installed) L a : b : 8 F : a : 8., b :.. No. Part Name Flange Oval Rotors Transmission Gerar Box In case of a meter with cooling fin, add mm to dim F above. Approx. Mass: kg Flange-to-Flange Dimensions (L) Nominal Size (mm) Flange Rating JIS K RF ANSI RF ANSI RF L (mm) 8 Anchor Bolt xx Hole Flow
6 MODEL CODE NUMBER st Group nd Group Basic Meter A Code No. Item Description L Liquid service flowmeter Application K Meter conforming to Reference Oil Meters, Standard Oil Meters, and Weights and Measures Law B FC (cast iron) Material of Metering C SCSA Element Q FC(w/surface treatment) Small size mm (") Meter Size Small size, mm ( ) Large size; mm ( ) Single case construction (small size) Flange Bore Single case construction (large size) Direct-reading register (LW) Direction-coupled Direct-reading register w/reset counter (LW) Resettable register (LW) Resettable register/printer combination (LW), Accumlative type Accuracy Adjustor and Mounting Adaptor Fixed type adjustor AG or AG provided. Convenient type adjustor AF provided. Angle adaptor + Fixed type adjustor AG or AG provided. Angle adaptor + Convenient type adjuster AF provided. Cooling fin + Fixed type adjustor AG or AG provided. Cooling fin + Convenient type adjustor AF provided. Other than above (Angle adaptor is used to mount LW, LW register at angle.) (Cooling fin is used in applications where operating temp. exceeds 8 C and PG or PGS pulse generator is added.) Accuracy (Linearity): ±.% rd Group Basic Meter B Generator Code No. Item Description Material F SCPH (Steel casting) Nominal pressure K Pressure Rating Nominal pressure K Nominal pressure K Bearings Carbon plain bearings Transmission System Magnetic coupling (uniform motion gear magnetic coupling reduction gears) Unfactored Pulse Generation Factored Pulse Generation Mechanical Temperature Compensator and Pulse Generator Combination th Group C D A B C D A B C D Where pulse generator is not required. PGS voltage pulse ( VDC, wires) PGSEP(flameproof construction)voltage pulse ( VDC, wires) PGD Non contact pulse ( VDC, wires) PGDEP EP type Non contact pulse ( VDC, wires) Other than above Where pulse generator is not required. PG voltage pulse ( VDC, wires) PGEP (flameproof construction) voltage pulse ( VDC, wires) PGS voltage pulse ( VDC, wires) PGSEP (flameproof construction) voltage pulse (VDC, wires) PG Contact pulse (Dry read switch) PGEP Contact pulse (Dry read switch) PGD Non contact pulse ( VDC, wires) PGDEP EP type Non contact pulse ( VDC, wires) Other than above Where mechanical temp. compensator is not required. Mechanical temp. compensator (ATC) provided. Where factored pulse is required upon mechanical temp. compensation (ATC + PG) Where factored pulse is required upon mechanical temp. compensation (ATC + PGEP) Where factored pulse is required upon mechanical temp. compensation (ATC + PGS) Where factored pulse is required upon mechanical temp. compensation (ATC + PGSEP) Where factored pulse is required upon mechanical temp. compensation (ATC + PG) Where factored pulse is required upon mechanical temp. compensation (ATC + PGEP) Where factored pulse is required upon mechanical temp. compensation (ATC + PGD) Where factored pulse is required upon mechanical temp. compensation (ATC + PGDEP) Other than above * Liquids which polymerize or vaporize easily such as Vinyl chloride monomer, ethylene oxide. etc.
7 When you make inquiries, please state the following: Item Description Fluid to be metered Name, viscosity, sp. gr., composition, presence of suspended foreign solids Flow range (m /h) Max., normal, min. Temperature ( C) Max., normal, min. Pressure (MPa, kgf/cm ) Max., normal, min. Direction of flow Right Left or Top Bottom Connection flanges Flange size (mm), flange rating Pump Type, capacity 8 Flowmeter, pump, strainer relations P S M piping Application Process control, transaction, etc. Accuracy required ± % Type Direct-reading register, resettable, register, etc. Accessories required Strainer, air eliminator, companion flanges Supplementary equipment required Automatic temperature compensator, Continuous accuracy adjustor Quantities of units desired (accessories inclusive) Remote Instrumentation Signal type and application (totalizer, indicator, recorder, controller, computer input, data logger input, batch, blend) Pulse generator type and signal unit Full scale and unit Flowmeter to receiving instrument distance Power source, voltage, frequency Receiving instrument Automatic Batching Quantity per batch, preset full scale Time required for each batch Daily total number of batch Allowable error in each batch Operating air pressure, power source, voltage, frequency Valve used and accessories
8 The specification as of Sep., is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative:
Series DMHF Heat Meter
Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationRosemount 1595 Conditioning Orifice Plate
Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe
More informationUltrasonic Heat Flow Meters
APPLICATIONS Measuring heat flow Sewage and drainage water with small particle quantity Beverage and food processors HVAC hot and cool water Water and waste treatment Power plants, heat energy boiler feed
More informationInc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS
FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.
More informationSONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS
SONICMAX UL3400C 3-EAM Compact Ultrasonic lowmeter OUTLINE The SONICMAX UL3400C is a converter-integrated ultrasonic flowmeter for inline liquid measurement with 3 pairs of ultrasonic sensors. The 3-beam
More informationMicro Motion R-Series General Purpose Mass and Volume Flowmeter
Product Data Sheet PS 00363 February 2002 Micro Motion R-Series General Purpose Mass and Volume Flowmeter Now available with MVD Technology TYPE EL OCTOBER 2001 www.micromotion.com Micro Motion R-Series
More informationUltra Sonic Flowmeter DATASHEET
Ultra Sonic Flowmeter DATASHEET JUNHO 2013 ULTRASONIC-FLOWMETER NON-INVASIV / CLAMP-ON-SENSORS Type: IS210-S Technical Information 2013 FLOW THE EXPERT IN LEVEL AND FLOW IS210 Technical Information Intra-Automation
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES
The Transit Time Flow Meter of TTFM100 NEW GENERATION (NG) series measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe. This
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationRosemount 1595 Conditioning Orifice Plate
Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before
More informationRosemount 1595 Conditioning Orifice Plate
Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe
More informationVEGA II. Electronic counter. The solutions that count
VEGA II Electronic counter www.isoilmeter.com The solutions that count LEAFLET: PR/VE/ Edition April 25 The VEGA II electronic counter is compatible with almost any type of flow meter, it is an instrument
More informationFH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications
FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management
More informationDFW Ultrasonic Water Meters
2012 NEW RELEASE DFW Ultrasonic Water Meters Waterworks and Industrial applications, DN32 600 Available Battery powered -- 6 years life expectancy No moving parts Rugged mechanical design -- IP68 Built-in
More information"PVL" SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev)
"PVL" SERIES Fixed Displacement - Single PVL Up to 5 (70 ), cm /rev (7 CU.IN./rev) Pub. EC-0 The PVL series single pumps are designed for use with small size machine tools requiring comparatively low pressure
More informationNIVOSWITCH VIBRATING FORK LEVEL SWITCHES
For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini
More informationThermal Mass Flowmeter Sensyflow FMT200-D
Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring
More informationAssembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug
Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationUPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo
UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline
More informationOptical encoding film disc mini board with integrated infrared photo sensor and LED operating indicator round, 5-pin output socket (180, DIN 41524)
Quick reference 200 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Not applicable for ex-proof areas Application The Pulse Generator for RITTER Drum-type
More informationFOR LIQUIDS AND SOLIDS
FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10
More informationVESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS)
VESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS) Reference: - June 2012 Kral Fuel Flowmeters History: TECHNICAL APPROACH The Kral Flowmeter was developed over 20 years ago a solution to an internal
More informationSeries DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from
Series DMTFB Clamp-on Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art
More informationKRAL Electronics BEM 300 and BEM 500.
KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS ULTRAFLO UFD3 ULTRASONIC CLAMP-ON FLOW METER FIXED OPTION PORTABLE OPTION (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 Introduction
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement OIL-Check 400 For permanent and highly precise measurement of the vaporous
More informationVAREC 5000/5010 SERIES FLAME ARRESTERS
VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL
More informationExplosion-Proof Gauge Pressure Transmitter
Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar
More informationRosemount 1595 Conditioning Orifice Plate
Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationACCESSORIES Pulse Generator V4.11 Data Sheet
03.33 Quick reference: 00 pulses per revolution of measuring drum For use with TG0 to TG0, BG4 to BG100 Uni-directional Not applicable for ex-proof areas Application: Components: Description: The Pulse
More informationDifferential Pressure Transmitter STK336
SENSE Instruments CO., LTD. Production address: # 1515 Chuanqiao RD.Jinqiao Export processing Industrial Zone Pudong New Area 201206 Shanghai China Telefon: +86(21) 5854 0878 Telefax: +86(21) 5899 3196
More informationModel FP-100 General Specification
Model General Specification Features! Improved metering accuracy and functionality! Single key access to most important parameters! Display of data in userselectable, engineering units! Self diagnostics
More informationScrew-Type Flow Meter SVC
Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.
More informationThis explosion proof Pulse Generator is equipped with an inductive sensor for use in
Quick reference 50 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Applicable for ex-proof areas (1) Application The Pulse Generator for RITTER Drum-type
More informationThe 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.
Varec 00A Series The 00A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Introduction Varec s have been the industry standard for over
More informationUPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps
VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More informationOval Gear Meter OGM PLUS
Precise volume measurement Reliable process control High-grade materials Resistant to chemicals Not affected by changes in viscosity Elados EMP pump coordinated flow rates Direct connection to an EMP E60
More informationMinilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values
Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and
More informationUltrasonic Flow Meter Brochure
Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationVane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing
Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables
More informationFamily of Water Cut Analyzers
Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water
More informationSTAF, STAF-SG, STAF-R, STAG
STAF, STAFSG, STAFR, STAG Balancing valves 0. Technical description Applications: STAF, STAFSG, STAG: Heating and cooling systems STAFR: Heating and cooling systems Tapwater systems Functions: Balancing
More informationSSV Special Compensating Bypass Check Valve
V 18-0 pecial Compensating Bypass Check Valve ew - 0 ANI 0-0 Δp V R V pecial Compensating Bypass Check Valve V 18-0 (type with integrated non-return valve in the bypass) Range of Applications Compared
More informationClear Benefits of the KRAL Electronic.
Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often
More informationBalancing valve PN 16 and PN 25 DN
STAF, STAF-SG Balancing valve PN and PN DN 0-00 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing
More information97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >
More informationData sheet deltwavec-f
deltawavec vec-f Data sheet deltwavec-f 1- Channel, 2- Channel, Ex Ultrasonic clamp-on flowmeter for liquids Lindberghstrasse 4, 82178 Puchheim Telefon 089-80906-0, Telefax 089-80906-200 http://www.systec-controls.de
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI
SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or
More informationClamp-On Transit Time Ultrasonic Flow Meters
APPLICATIONS Water (hot water, cooling water, potable water, sea water etc.) Petroleum products Chemicals, including alcohol, acids, etc HVAC, energy measurement system Beverage, food and pharmaceutical
More informationDigital pressure gauge Data Sheet: DMM2.431.R1.EN
Data Sheet: DMM.431.R1.EN www.aep.it Digital pressure gauge DMM is a digital pressure gauge made according to the most modern technologies to ensure a high level of reliability, versatility and practicality
More informationCR, CRN high pressure
GRUNDFOS DATA BOOKLET CR, CRN high pressure Vertical multistage centrifugal pumps 5/6 Hz Contents Product Data Performance range 3 Product range 4 Applications 4 CRNE 1 and 3 HS 5 CRN 5, 1, 15, SF 6 x
More informationMobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB
Product Data Sheet February 2015 IP207, Rev DB Mobrey Squitch 2 Ultrasonic Liquid Level Switch A compact, self-contained, ultrasonic gap sensor, designed for switching in clean, non-aerated liquids BSPT
More informationRA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols
/2.9 Gear Pump Model G2 (Series X For Flange Mounting with SE threaded Ports s to 22... 6 PSI (2 bar....7 in /rev. (22. cm /rev. /2.9 eplaces: 2.92 New principle of sealing the pump body, increases service
More informationInstruction Manual, Alfa Laval Rotacheck Sensor and Relay
Instruction Manual Alfa Laval Rotacheck Sensor and Relay Covering Standard Instruments Instruments delivered with ATEX Certification in accordance with Directive 94/9/EC IM-TE91A663-EN9 ESE01763EN Date
More informationRHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter
RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match
More informationLevel measurement. Applications. Special features. Description
Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data
More informationInstruction Manual DR58 Brass Paddle Wheel Flow Meter
Instruction Manual DR58 Brass Paddle Wheel Flow Meter PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden-Nordenstadt Tel.: ++49-(0)6122-7055-0 Fax: ++49-(0)6122-7055-50 Email: info@pkp.de Table
More informationRosemount 1595 Conditioning Orifice Plate
Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before working with the product.
More informationISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids
Stainless steel diaphragm SUS630 and SUS304 are used for wetted parts. For General Purpose Fluids With Backlight Digital Pressure Switch Series ZSE5B (For vacuum) ISE5B (For positive ) Leakage rate: 1
More informationFlow VA 500/
VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety
More informationMicro Motion R-Series Mass and Volume Flowmeter
Product Data Sheet PS-363, Rev. B March 24 Micro Motion R-Series Mass and Volume Flowmeter With MVD Technology TM Micro Motion Micro Motion R-Series Flowmeters Welcome to a new era in measurement technology!
More informationNF770 Temperature Compensation Liquid Flow Computer
NF770 Temperature Compensation Liquid Flow Computer Overview Mass Flow measurement at a comparatively low cost can be achieved using the Model NF770 Liquid Flow Computer, an RTD temperature sensor and
More information700Z JIS. 10K Aluminum Butterfly Valve. Evolution of Long Sellers Sealing performance and Durability Improved! 40 to 300mm
0K Aluminum Butterfly Valve 0Z Valve nominal size 0 to 00mm Max.working pressure MPa Working temperature range C JIS JIS B 0 Compliant (This product conforms to General Specifications for Machinery and
More informationNEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.
NEW product No, NPPDF 6-01E-3 Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure
More informationFlow. Order number VA 550. Order no. VA 570. Further accessories A_...M_
Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573
More informationAnalog electric proportional joysticks JEP
Analog electric proportional joysticks JEP 2.01.09 Index: Description: Page 3 Technical features: Page 4 Metering curve: Page 5 Overall dimensions: Pages 6 9 Control handles: Page 10 Rubber boot: Page
More informationApplications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement
MEASURE TODAY. ENSURE TOMORROW REGAL Series RH20 Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement Applications The RH20 handheld flowmeter is one of the most powerful yet portable
More informationPrecision digital pressure gauge Model CPG1500
Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration
More informationRHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter
RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter Features Rack/Panel Mounting Operate with RHM sensor in hazardous area Selectable Units for Mass, Volume, Density and Temperature Positive,
More informationRHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter
RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationScanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A
NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter
More informationScrew-Type Flow Meter SVC
Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.
More informationUniversal IV Water Cut Meter
DREXELBROOK DATA SHEET Universal IV Water Cut Meter with Density Compensation Use the Best For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable
More informationStandard Bellows Metering Pumps
Standard Bellows Metering Pumps Bellows Metering Pumps operate on a positive displacement principle. Pumps are designed to displace both corrosive and noncorrosive fluids. Accurate to ± 0.5% from stroke
More informationLAUREL ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview
SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor
More information... f l o w measurement & control...
... f l o w measurement & control... ELECTROMAGNETIC FLOWMETERS OPEN CHANNEL MAGNETIC FLOWMETER PARTLY FILLED PIPE MAGNETIC FLOWMETER VENTURI & PARSHALL FLUMES ULTRASONIC LEVEL MEASUREMENT ULTRASONIC OPEN
More informationTRITIUM COLLECTION SYSTEMS
F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs TRITIUM COLLECTION SYSTEMS 100 120 VAC KH3-200 MRB200H3 MRB200H3-60ML MRB500H3 TCS-3000-BL TCS-5000-BLDC Rev: 13 June 2018 Tel:
More informationDREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance
USE THE BEST For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable and accurate products at a reasonable cost. We offer the highest pressure
More informationConductivity Transmitters
Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows
More informationLAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationScrew-Type Flow Meter SVC
Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.
More informationProduct Information. POSITIP PT 8016 Digital Readout for Manually Operated Machine Tools
Product Information POSITIP PT 816 Digital Readout for Manually Operated Machine Tools 11/218 POSITIP PT 816, PT 816 Active The convenient digital readout for milling, drilling, and boring machines, and
More informationSelection can be made from different capacities (ranging from 100kN to 2000kN) from HL 590 / HL590 (FL) series or HLC 591 / HLC 591 (FL) series.
Universal Testing Machines UNIVERSAL TESTING MACHINE HEICO UTM is suitable to conduct following tests - (i) Compression (ii) Tension (iii) Transverse (iv)bending (v) Shear (vi) Hardness and many others
More informationMultiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual
Issue/Rev. 0.1 (5/05) Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual Bulletin MNMP003 Contents Section 1 Introduction... Page 3 Section 2 TopFlow MultiPhase Meter... Page 4 Sensor
More informationRHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter
RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter Features Rack/Panel Mounting Operate with RHM sensor in hazardous area Selectable Units for Mass, Volume, Density and Temperature Positive,
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation
More informationLevel and temperature switch Nivotemp NT-M, NT-MD
Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible
More informationDN100 (4") - DN500 (20") Hot Tappings
DN00 (4") - DN500 (20") Hot Tappings TONISCO B40 Hot Tapping Machine is versatile and easy to operate. It has a full range capability of setting valves DN00 DN500 by completing it with proper adapters.
More informationFlow Measurement SITRANS F C
Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,
More informationRadiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems
6 EN - Straight valves VDN Angle valves VEN Reverse angle valves VUN Radiator Valves NF norm, for -pipe heating systems VDN VEN VUN Valve bodies made of brass, mat nickel-plated DN, DN and DN (VDN, VEN
More information