1 OVAL FLOWMETER Meter Size:, ( Single Case Construction ) with Powerful Magnetic Coupling GENERAL SPECIFICATION GS.No.GBB8--E GENERAL The OVAL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear rotors. It is capable of metering the actual quantity of the material passing through it with a high degree of precision over a wide flow range and accepts any liquid irrespective of its chemical or physical properties. It s accuracy, reliability and quality has made it a highly valued industrial instrument. FEATURES. Simple design makes this meter easy to disassemble and allows for ease in maintenance and inspection.. Introduction of a powerful magnetic coupling makes this meter compatible with a variety of direct-reading registers.. Compatible with a variety of pulse generators that allows a wide selection of remote flow instrumentation.. Can accept liquids of widely varying chemical and physical properties by selecting appropriate meter materials.. A complete line of models are available to meet a broad range of pressure and temperature requirements. GENERAL SPECIFICATIONS Meter size: Meter size: Meter Size Item Nominal Size, mm (inch) Construction Transmission System Materials Linearity Repeatability Operating Temp. Range Liquids to be Metered Flow Direction Finish Rotors Bearings Linearity ±.% ±.% (") FC, SCSA, FC(w/surface treatment) Right Left (std.), Left Right, Bottom Top ( ), ( ) Single case construction Type Magnetic coupling* SCPH Carbon ±.% or ±.% ±.% or ±.% ~ + C ~ + C Petroleums Body, transmission gear box & register case: Munsell.G 8/ Frame: Munsell N. FC, FC(w/surface treatment) Right Left (std.), Left Right, Notes: *Refer to description in the model code number Flange Ratings and Max. Operating Pressures: MPa Pressure Rating K Outer Flange Rating JIS Flange Rating ANSI K K K K SCPH.8. K SCPH... NOTE: Reference temperature are C. SCPH.... OVAL Corporation Head Office: Tokyo; Tel Fax Beijing Office: Tel., Fax Tel Overseas Branch Offices: Seoul. Singapore. Taipei

2 FLOW RANGE Table A Flow Range for Liquid in General (Linearity : ±.%) (Operating temp. range:- ~ + C) Meter Size Bore, mm Operating Condition Type of Liquid Temp., Viscosity Range Continuous Intermittent A.I.F. ~ ~ Continuous ~ Intermittent ~ 8 A.I.F. Unit in m /h Liquids other than water Unite in mpa.s Less than.. ~.8.8 ~ ~ ~ ~ ~ 8 ~ 8 ~ ~ ~ 8 ~ ~ ~ ~ 8 ~ ~ 8 ~ 8 8 ~ ~ ~ ~ 8 ~ ~ 8 ~ ~ 8 ~ 8 8 ~ ~ ~ ~ 8 8 Table B Flow Range for Liquid in General (Linearity : ±.%) (Operating temp. range:- ~ + C) Meter Size Bore, mm Operating Condition NOTES:. In the Operating Condition column Continuous means continuous operation; Intermittent means no more than 8 hours operation a day, and A.I.F. indicates allowable instantaneous flow rate.. Flow range should be selected within the Continuous or Intermittent range specified.. For applications where viscosity exceeds mpa.s, specially machined rotors are used. REGISTERS AND UNIT REGISTRATION Model Dial and Pointer Total Counter Volume per Point Rev. (L) Min. Reading (L) Max. Readout (L) LSD Drum (L) Direct-reading (LW) Direct-reading w/reset Counter (LW) Resettable (LW, ) Type of Liquid Temp., Viscosity Range Continuous Intermittent A.I.F. ~ ~ Continuous ~ Intermittent ~ 8 A.I.F. Unit in m /h Liquids other than water Unite in mpa.s Less than.. ~.8.8 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 8 ~ 8 ~ 8 ~ ~ ~ 8 ~ ~ ~ ~ 8 ~ ~ 8 ~ ~ 8 ~ 8 8 ~ ~ ~ ~ 8 8 : Standard. As to general specifications registers, refer to individual General Specification Sheets. (LSD: Least Significant Digit) Unit of Factored Pulse Generated Unit of Unfactored Pulse Generation Volume per Pointer Rev. L/rev. Meter Size Genrator Pulse No. Signal Unit (L/P) P / rev. PG. PGS Freq. at Max. (Hz) (L/P) P / rev. Freq. at Max. (Hz) (L/P) P / rev. PG. PGD Freq. at Max. (Hz) P / rev. (L/P) Freq. at Max. (Hz) Max. m /h PGS Nominal Meter Factor (ml/p) Less than Full Scale (m /h) More than Full Scale (m /h) () () : Standard For detailed pulse generator specifications, see individual General Specification Sheets. 8 () 8 () Full Scale for Indicator or Recorder Meter Size Full Scale m /h 8 8 Full Scale L/min. 8

3 Oval Oval Oval Oval OVAL MODEL EL REGISTERS AND REMOTE INSTRUMENTATION SYSTEMS Direct-coupled s and Remote Instrumentation System with Pulse Generator Equipped Totalizer EL EL Batch Controller EL8 Batch Coontroller EL8 Series Blender EL Series Multiple Temp. Compensator EL Series 8 Digital Controller PG Pulse Generator (Contact-closure) PG, PGD, PGS, Voltage Pulse Generator LW 8 LW Factored Pulse Generation Basic Oval Flowmeter Unfactored Pulse Generation Convenient Type Accuracy Adjustor (AF) Fixed Type Accuracy Adjustor (AG) 8 PG S LW F/I Converter Converter/ Compensator LW SU SU EL8 Indicator EL Recorder Controller, Analog Instrument Direct-coupled s without Pulse Generator LW Registser 8 LW 8 LW, Basic Oval Flowmeter NOTES:. For details of the direct-coupled register, pulse generators, receiving instruments, etc., see individual General Sepcification Sheets.. Flameproof construction of pulse generators are available. For intrinsically safe construction, pulse repeater is provided.

4 TYPICAL PERFORMANCE CHARACTERISTICS Meter error, % +.. Pressure Drop, kpa Gasoline.mPa.s Kerosene.mPa.s Gas Oil mpa.s Fuel Oil mpa.s Meter Size Meter Size 8 8, m /h DIMENSIONS Meter Size Unit in mm (LW Installed) ;; D L a: F b:8 A R a: Transmission Gear Box w/external Accuracy Adjustor (GB- ) b: Transmission Gear Box w/built-in Accuracy Adjustor (GB-) No. Part Name Flange Oval Rotors Conversion Gear Ass y Mat l Symbol and Press. Rating F F * In case of cooling fin coupled, add mm to F above. F R D A a b Mass kg 8 8 Flange-to-Flange Dimensions (L) Meter Size Nom. size mm (") Flange ratings JIS K RF JIS K RF JIS K RF ANSI RF ANSI RF Pressure Rating K K Unit in mm

5 DIMENSIONS Meter Size (LW Installed) L a : b : 8 F : a : 8., b :.. No. Part Name Flange Oval Rotors Transmission Gerar Box In case of a meter with cooling fin, add mm to dim F above. Approx. Mass: kg Flange-to-Flange Dimensions (L) Nominal Size (mm) Flange Rating JIS K RF ANSI RF ANSI RF L (mm) 8 Anchor Bolt xx Hole Flow

6 MODEL CODE NUMBER st Group nd Group Basic Meter A Code No. Item Description L Liquid service flowmeter Application K Meter conforming to Reference Oil Meters, Standard Oil Meters, and Weights and Measures Law B FC (cast iron) Material of Metering C SCSA Element Q FC(w/surface treatment) Small size mm (") Meter Size Small size, mm ( ) Large size; mm ( ) Single case construction (small size) Flange Bore Single case construction (large size) Direct-reading register (LW) Direction-coupled Direct-reading register w/reset counter (LW) Resettable register (LW) Resettable register/printer combination (LW), Accumlative type Accuracy Adjustor and Mounting Adaptor Fixed type adjustor AG or AG provided. Convenient type adjustor AF provided. Angle adaptor + Fixed type adjustor AG or AG provided. Angle adaptor + Convenient type adjuster AF provided. Cooling fin + Fixed type adjustor AG or AG provided. Cooling fin + Convenient type adjustor AF provided. Other than above (Angle adaptor is used to mount LW, LW register at angle.) (Cooling fin is used in applications where operating temp. exceeds 8 C and PG or PGS pulse generator is added.) Accuracy (Linearity): ±.% rd Group Basic Meter B Generator Code No. Item Description Material F SCPH (Steel casting) Nominal pressure K Pressure Rating Nominal pressure K Nominal pressure K Bearings Carbon plain bearings Transmission System Magnetic coupling (uniform motion gear magnetic coupling reduction gears) Unfactored Pulse Generation Factored Pulse Generation Mechanical Temperature Compensator and Pulse Generator Combination th Group C D A B C D A B C D Where pulse generator is not required. PGS voltage pulse ( VDC, wires) PGSEP(flameproof construction)voltage pulse ( VDC, wires) PGD Non contact pulse ( VDC, wires) PGDEP EP type Non contact pulse ( VDC, wires) Other than above Where pulse generator is not required. PG voltage pulse ( VDC, wires) PGEP (flameproof construction) voltage pulse ( VDC, wires) PGS voltage pulse ( VDC, wires) PGSEP (flameproof construction) voltage pulse (VDC, wires) PG Contact pulse (Dry read switch) PGEP Contact pulse (Dry read switch) PGD Non contact pulse ( VDC, wires) PGDEP EP type Non contact pulse ( VDC, wires) Other than above Where mechanical temp. compensator is not required. Mechanical temp. compensator (ATC) provided. Where factored pulse is required upon mechanical temp. compensation (ATC + PG) Where factored pulse is required upon mechanical temp. compensation (ATC + PGEP) Where factored pulse is required upon mechanical temp. compensation (ATC + PGS) Where factored pulse is required upon mechanical temp. compensation (ATC + PGSEP) Where factored pulse is required upon mechanical temp. compensation (ATC + PG) Where factored pulse is required upon mechanical temp. compensation (ATC + PGEP) Where factored pulse is required upon mechanical temp. compensation (ATC + PGD) Where factored pulse is required upon mechanical temp. compensation (ATC + PGDEP) Other than above * Liquids which polymerize or vaporize easily such as Vinyl chloride monomer, ethylene oxide. etc.

7 When you make inquiries, please state the following: Item Description Fluid to be metered Name, viscosity, sp. gr., composition, presence of suspended foreign solids Flow range (m /h) Max., normal, min. Temperature ( C) Max., normal, min. Pressure (MPa, kgf/cm ) Max., normal, min. Direction of flow Right Left or Top Bottom Connection flanges Flange size (mm), flange rating Pump Type, capacity 8 Flowmeter, pump, strainer relations P S M piping Application Process control, transaction, etc. Accuracy required ± % Type Direct-reading register, resettable, register, etc. Accessories required Strainer, air eliminator, companion flanges Supplementary equipment required Automatic temperature compensator, Continuous accuracy adjustor Quantities of units desired (accessories inclusive) Remote Instrumentation Signal type and application (totalizer, indicator, recorder, controller, computer input, data logger input, batch, blend) Pulse generator type and signal unit Full scale and unit Flowmeter to receiving instrument distance Power source, voltage, frequency Receiving instrument Automatic Batching Quantity per batch, preset full scale Time required for each batch Daily total number of batch Allowable error in each batch Operating air pressure, power source, voltage, frequency Valve used and accessories

8 The specification as of Sep., is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative:

Series DMHF Heat Meter

Series DMHF Heat Meter Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe

More information

Ultrasonic Heat Flow Meters

Ultrasonic Heat Flow Meters APPLICATIONS Measuring heat flow Sewage and drainage water with small particle quantity Beverage and food processors HVAC hot and cool water Water and waste treatment Power plants, heat energy boiler feed

More information

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.

More information

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS SONICMAX UL3400C 3-EAM Compact Ultrasonic lowmeter OUTLINE The SONICMAX UL3400C is a converter-integrated ultrasonic flowmeter for inline liquid measurement with 3 pairs of ultrasonic sensors. The 3-beam

More information

Micro Motion R-Series General Purpose Mass and Volume Flowmeter

Micro Motion R-Series General Purpose Mass and Volume Flowmeter Product Data Sheet PS 00363 February 2002 Micro Motion R-Series General Purpose Mass and Volume Flowmeter Now available with MVD Technology TYPE EL OCTOBER 2001 www.micromotion.com Micro Motion R-Series

More information

Ultra Sonic Flowmeter DATASHEET

Ultra Sonic Flowmeter DATASHEET Ultra Sonic Flowmeter DATASHEET JUNHO 2013 ULTRASONIC-FLOWMETER NON-INVASIV / CLAMP-ON-SENSORS Type: IS210-S Technical Information 2013 FLOW THE EXPERT IN LEVEL AND FLOW IS210 Technical Information Intra-Automation

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES The Transit Time Flow Meter of TTFM100 NEW GENERATION (NG) series measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe. This

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe

More information

VEGA II. Electronic counter. The solutions that count

VEGA II.   Electronic counter. The solutions that count VEGA II Electronic counter www.isoilmeter.com The solutions that count LEAFLET: PR/VE/ Edition April 25 The VEGA II electronic counter is compatible with almost any type of flow meter, it is an instrument

More information

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management

More information

DFW Ultrasonic Water Meters

DFW Ultrasonic Water Meters 2012 NEW RELEASE DFW Ultrasonic Water Meters Waterworks and Industrial applications, DN32 600 Available Battery powered -- 6 years life expectancy No moving parts Rugged mechanical design -- IP68 Built-in

More information

"PVL" SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev)

PVL SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev) "PVL" SERIES Fixed Displacement - Single PVL Up to 5 (70 ), cm /rev (7 CU.IN./rev) Pub. EC-0 The PVL series single pumps are designed for use with small size machine tools requiring comparatively low pressure

More information

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini

More information

Thermal Mass Flowmeter Sensyflow FMT200-D

Thermal Mass Flowmeter Sensyflow FMT200-D Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100

More information

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline

More information

Optical encoding film disc mini board with integrated infrared photo sensor and LED operating indicator round, 5-pin output socket (180, DIN 41524)

Optical encoding film disc mini board with integrated infrared photo sensor and LED operating indicator round, 5-pin output socket (180, DIN 41524) Quick reference 200 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Not applicable for ex-proof areas Application The Pulse Generator for RITTER Drum-type

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10

More information

VESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS)

VESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS) VESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS) Reference: - June 2012 Kral Fuel Flowmeters History: TECHNICAL APPROACH The Kral Flowmeter was developed over 20 years ago a solution to an internal

More information

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from Series DMTFB Clamp-on Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art

More information

KRAL Electronics BEM 300 and BEM 500.

KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500. KRAL Electronics BEM 300 and BEM 500 Electronic units that are coordinated to KRAL flowmeters and their diverse applications. Coordinated to the flowmeters and their

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS ULTRAFLO UFD3 ULTRASONIC CLAMP-ON FLOW METER FIXED OPTION PORTABLE OPTION (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 Introduction

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement OIL-Check 400 For permanent and highly precise measurement of the vaporous

More information

VAREC 5000/5010 SERIES FLAME ARRESTERS

VAREC 5000/5010 SERIES FLAME ARRESTERS VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL

More information

Explosion-Proof Gauge Pressure Transmitter

Explosion-Proof Gauge Pressure Transmitter Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only

More information

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2-16; P=87 PSI Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,

More information

ACCESSORIES Pulse Generator V4.11 Data Sheet

ACCESSORIES Pulse Generator V4.11 Data Sheet 03.33 Quick reference: 00 pulses per revolution of measuring drum For use with TG0 to TG0, BG4 to BG100 Uni-directional Not applicable for ex-proof areas Application: Components: Description: The Pulse

More information

Differential Pressure Transmitter STK336

Differential Pressure Transmitter STK336 SENSE Instruments CO., LTD. Production address: # 1515 Chuanqiao RD.Jinqiao Export processing Industrial Zone Pudong New Area 201206 Shanghai China Telefon: +86(21) 5854 0878 Telefax: +86(21) 5899 3196

More information

Model FP-100 General Specification

Model FP-100 General Specification Model General Specification Features! Improved metering accuracy and functionality! Single key access to most important parameters! Display of data in userselectable, engineering units! Self diagnostics

More information

Screw-Type Flow Meter SVC

Screw-Type Flow Meter SVC Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.

More information

This explosion proof Pulse Generator is equipped with an inductive sensor for use in

This explosion proof Pulse Generator is equipped with an inductive sensor for use in Quick reference 50 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Applicable for ex-proof areas (1) Application The Pulse Generator for RITTER Drum-type

More information

The 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.

The 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Varec 00A Series The 00A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Introduction Varec s have been the industry standard for over

More information

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

Oval Gear Meter OGM PLUS

Oval Gear Meter OGM PLUS Precise volume measurement Reliable process control High-grade materials Resistant to chemicals Not affected by changes in viscosity Elados EMP pump coordinated flow rates Direct connection to an EMP E60

More information

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and

More information

Ultrasonic Flow Meter Brochure

Ultrasonic Flow Meter Brochure Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

Family of Water Cut Analyzers

Family of Water Cut Analyzers Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water

More information

STAF, STAF-SG, STAF-R, STAG

STAF, STAF-SG, STAF-R, STAG STAF, STAFSG, STAFR, STAG Balancing valves 0. Technical description Applications: STAF, STAFSG, STAG: Heating and cooling systems STAFR: Heating and cooling systems Tapwater systems Functions: Balancing

More information

SSV Special Compensating Bypass Check Valve

SSV Special Compensating Bypass Check Valve V 18-0 pecial Compensating Bypass Check Valve ew - 0 ANI 0-0 Δp V R V pecial Compensating Bypass Check Valve V 18-0 (type with integrated non-return valve in the bypass) Range of Applications Compared

More information

Clear Benefits of the KRAL Electronic.

Clear Benefits of the KRAL Electronic. Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often

More information

Balancing valve PN 16 and PN 25 DN

Balancing valve PN 16 and PN 25 DN STAF, STAF-SG Balancing valve PN and PN DN 0-00 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

Data sheet deltwavec-f

Data sheet deltwavec-f deltawavec vec-f Data sheet deltwavec-f 1- Channel, 2- Channel, Ex Ultrasonic clamp-on flowmeter for liquids Lindberghstrasse 4, 82178 Puchheim Telefon 089-80906-0, Telefax 089-80906-200 http://www.systec-controls.de

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or

More information

Clamp-On Transit Time Ultrasonic Flow Meters

Clamp-On Transit Time Ultrasonic Flow Meters APPLICATIONS Water (hot water, cooling water, potable water, sea water etc.) Petroleum products Chemicals, including alcohol, acids, etc HVAC, energy measurement system Beverage, food and pharmaceutical

More information

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Digital pressure gauge Data Sheet: DMM2.431.R1.EN Data Sheet: DMM.431.R1.EN www.aep.it Digital pressure gauge DMM is a digital pressure gauge made according to the most modern technologies to ensure a high level of reliability, versatility and practicality

More information

CR, CRN high pressure

CR, CRN high pressure GRUNDFOS DATA BOOKLET CR, CRN high pressure Vertical multistage centrifugal pumps 5/6 Hz Contents Product Data Performance range 3 Product range 4 Applications 4 CRNE 1 and 3 HS 5 CRN 5, 1, 15, SF 6 x

More information

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB Product Data Sheet February 2015 IP207, Rev DB Mobrey Squitch 2 Ultrasonic Liquid Level Switch A compact, self-contained, ultrasonic gap sensor, designed for switching in clean, non-aerated liquids BSPT

More information

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols /2.9 Gear Pump Model G2 (Series X For Flange Mounting with SE threaded Ports s to 22... 6 PSI (2 bar....7 in /rev. (22. cm /rev. /2.9 eplaces: 2.92 New principle of sealing the pump body, increases service

More information

Instruction Manual, Alfa Laval Rotacheck Sensor and Relay

Instruction Manual, Alfa Laval Rotacheck Sensor and Relay Instruction Manual Alfa Laval Rotacheck Sensor and Relay Covering Standard Instruments Instruments delivered with ATEX Certification in accordance with Directive 94/9/EC IM-TE91A663-EN9 ESE01763EN Date

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

Standard Circulating Pumps

Standard Circulating Pumps Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match

More information

Level measurement. Applications. Special features. Description

Level measurement. Applications. Special features. Description Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data

More information

Instruction Manual DR58 Brass Paddle Wheel Flow Meter

Instruction Manual DR58 Brass Paddle Wheel Flow Meter Instruction Manual DR58 Brass Paddle Wheel Flow Meter PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden-Nordenstadt Tel.: ++49-(0)6122-7055-0 Fax: ++49-(0)6122-7055-50 Email: info@pkp.de Table

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before working with the product.

More information

ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids Stainless steel diaphragm SUS630 and SUS304 are used for wetted parts. For General Purpose Fluids With Backlight Digital Pressure Switch Series ZSE5B (For vacuum) ISE5B (For positive ) Leakage rate: 1

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

Micro Motion R-Series Mass and Volume Flowmeter

Micro Motion R-Series Mass and Volume Flowmeter Product Data Sheet PS-363, Rev. B March 24 Micro Motion R-Series Mass and Volume Flowmeter With MVD Technology TM Micro Motion Micro Motion R-Series Flowmeters Welcome to a new era in measurement technology!

More information

NF770 Temperature Compensation Liquid Flow Computer

NF770 Temperature Compensation Liquid Flow Computer NF770 Temperature Compensation Liquid Flow Computer Overview Mass Flow measurement at a comparatively low cost can be achieved using the Model NF770 Liquid Flow Computer, an RTD temperature sensor and

More information

700Z JIS. 10K Aluminum Butterfly Valve. Evolution of Long Sellers Sealing performance and Durability Improved! 40 to 300mm

700Z JIS. 10K Aluminum Butterfly Valve. Evolution of Long Sellers Sealing performance and Durability Improved! 40 to 300mm 0K Aluminum Butterfly Valve 0Z Valve nominal size 0 to 00mm Max.working pressure MPa Working temperature range C JIS JIS B 0 Compliant (This product conforms to General Specifications for Machinery and

More information

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display. NEW product No, NPPDF 6-01E-3 Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure

More information

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_ Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573

More information

Analog electric proportional joysticks JEP

Analog electric proportional joysticks JEP Analog electric proportional joysticks JEP 2.01.09 Index: Description: Page 3 Technical features: Page 4 Metering curve: Page 5 Overall dimensions: Pages 6 9 Control handles: Page 10 Rubber boot: Page

More information

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement MEASURE TODAY. ENSURE TOMORROW REGAL Series RH20 Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement Applications The RH20 handheld flowmeter is one of the most powerful yet portable

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter Features Rack/Panel Mounting Operate with RHM sensor in hazardous area Selectable Units for Mass, Volume, Density and Temperature Positive,

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter

More information

Screw-Type Flow Meter SVC

Screw-Type Flow Meter SVC Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.

More information

Universal IV Water Cut Meter

Universal IV Water Cut Meter DREXELBROOK DATA SHEET Universal IV Water Cut Meter with Density Compensation Use the Best For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable

More information

Standard Bellows Metering Pumps

Standard Bellows Metering Pumps Standard Bellows Metering Pumps Bellows Metering Pumps operate on a positive displacement principle. Pumps are designed to displace both corrosive and noncorrosive fluids. Accurate to ± 0.5% from stroke

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor

More information

... f l o w measurement & control...

... f l o w measurement & control... ... f l o w measurement & control... ELECTROMAGNETIC FLOWMETERS OPEN CHANNEL MAGNETIC FLOWMETER PARTLY FILLED PIPE MAGNETIC FLOWMETER VENTURI & PARSHALL FLUMES ULTRASONIC LEVEL MEASUREMENT ULTRASONIC OPEN

More information

TRITIUM COLLECTION SYSTEMS

TRITIUM COLLECTION SYSTEMS F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs TRITIUM COLLECTION SYSTEMS 100 120 VAC KH3-200 MRB200H3 MRB200H3-60ML MRB500H3 TCS-3000-BL TCS-5000-BLDC Rev: 13 June 2018 Tel:

More information

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance USE THE BEST For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable and accurate products at a reasonable cost. We offer the highest pressure

More information

Conductivity Transmitters

Conductivity Transmitters Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Screw-Type Flow Meter SVC

Screw-Type Flow Meter SVC Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.

More information

Product Information. POSITIP PT 8016 Digital Readout for Manually Operated Machine Tools

Product Information. POSITIP PT 8016 Digital Readout for Manually Operated Machine Tools Product Information POSITIP PT 816 Digital Readout for Manually Operated Machine Tools 11/218 POSITIP PT 816, PT 816 Active The convenient digital readout for milling, drilling, and boring machines, and

More information

Selection can be made from different capacities (ranging from 100kN to 2000kN) from HL 590 / HL590 (FL) series or HLC 591 / HLC 591 (FL) series.

Selection can be made from different capacities (ranging from 100kN to 2000kN) from HL 590 / HL590 (FL) series or HLC 591 / HLC 591 (FL) series. Universal Testing Machines UNIVERSAL TESTING MACHINE HEICO UTM is suitable to conduct following tests - (i) Compression (ii) Tension (iii) Transverse (iv)bending (v) Shear (vi) Hardness and many others

More information

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual Issue/Rev. 0.1 (5/05) Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual Bulletin MNMP003 Contents Section 1 Introduction... Page 3 Section 2 TopFlow MultiPhase Meter... Page 4 Sensor

More information

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter Features Rack/Panel Mounting Operate with RHM sensor in hazardous area Selectable Units for Mass, Volume, Density and Temperature Positive,

More information

Standard Circulating Pumps

Standard Circulating Pumps Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation

More information

Level and temperature switch Nivotemp NT-M, NT-MD

Level and temperature switch Nivotemp NT-M, NT-MD Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible

More information

DN100 (4") - DN500 (20") Hot Tappings

DN100 (4) - DN500 (20) Hot Tappings DN00 (4") - DN500 (20") Hot Tappings TONISCO B40 Hot Tapping Machine is versatile and easy to operate. It has a full range capability of setting valves DN00 DN500 by completing it with proper adapters.

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,

More information

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems 6 EN - Straight valves VDN Angle valves VEN Reverse angle valves VUN Radiator Valves NF norm, for -pipe heating systems VDN VEN VUN Valve bodies made of brass, mat nickel-plated DN, DN and DN (VDN, VEN

More information