1 HP ProLiant DL145 Server User Guide April 2005 (Fifth Edition) Part Number

2 Copyright 2005 Hewlett-Packard Development Company, L.P. AMD, Opteron, and Hyper-Transport are trademarks of AMD Corporation in the United States and other countries. Linux is a trademark of Linux Torvalds Corporation in the United States and other countries. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States and other countries. Intel is a trademark of Intel Corporation in the United States and other countries. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided as is without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. HP ProLiant DL145 Server User Guide April 2005 (Fifth Edition) Part Number

3 Contents About This Guide Audience Assumptions... vii Important Safety Information... vii Symbols on Equipment... vii Rack Stability... viii Symbols in Text... viii Related Documents...ix Getting Help...ix Technical Support...ix HP Website...ix Authorized Reseller...ix Reader s Comments...x Chapter 1 Server Component Identification Front Panel Components Rear Panel Connectors Rear Panel LEDs System Board Components J9 CMOS Jumper Chapter 2 Server Operations Powering Up the Server Powering Down the Server Extending the Server from the Rack Removing the Server from the Rack Removing the Access Panel and Chassis Stiffener Chapter 3 Server Setup Optional Installation Services Rack Planning Resources Optimum Environment Space and Airflow Requirements Temperature Requirements Power Requirements Grounding Requirements Rack Warnings and Cautions HP ProLiant DL145 Server User Guide iii

4 Contents Installing Hardware Options Server Shipping Contents Installing the Server into the Rack Operating System Installation Registering the Server Routine Maintenance Chapter 4 Hardware Options Installation Processors Memory Options Memory Guidelines Removing a Media Bay Blank or a DVD Drive Installing a DVD Drive EIDE Hard Drive Installation Removing the EIDE Hard Drives PCI-X Expansion Board SCSI Hard Drive Installation Installing the SCSI Drives Installing the SCSI Controller Routing the SCSI Cable Additional Information Supported Features Chapter 5 Operating System Installation and Software Overview Operating System Installation ProLiant DL145 Support CD PXE Deployment Software and Utilities ROMPaq Utility Management Processor Flash Utility Diagnostics Utility BIOS Setup Utility Server Management Configuring the Serial Port Configuring Access Through the Serial Port Configuring Access Through the Network User Accounts Accessing the Management Processor CLI Using CLI Commands BIOS Console Text Redirection Linux Operating System Redirection Windows EMS Management Using the Watch Dog Timer System Event Log Systems Insight Manager IPMI System Management iv HP ProLiant DL145 Server User Guide

5 Contents Appendix A Regulatory Compliance Notices Regulatory Compliance Model Number... A-1 Federal Communications Commission Notice... A-1 Class A Equipment... A-1 Class B Equipment... A-2 Declaration of Conformity for Products Marked with the FCC Logo, United States Only... A-2 Modifications... A-3 Cables... A-3 Canadian Notice (Avis Canadien)... A-3 Class A Equipment... A-3 Class B Equipment... A-3 Mouse Compliance Statement... A-3 European Union Notice... A-4 Japanese Notice... A-4 BSMI Notice... A-4 Laser Compliance... A-5 Battery Replacement Notice... A-5 Appendix B Electrostatic Discharge Preventing Electrostatic Damage...B-1 Grounding Methods...B-1 Appendix C System Battery Battery Replacement...C-1 Appendix D Server Error Messages Appendix E Server Specifications Server Specifications...E-1 Appendix F Troubleshooting If the Server Does Not Start... F-1 Diagnosis Steps... F-2 Problems After Initial Startup... F-4 Other Troubleshooting Resources... F-6 Index HP ProLiant DL145 Server User Guide v

6

7 About This Guide This guide provides step-by-step instructions for installation, and reference information for operation, troubleshooting, and future upgrades for the HP ProLiant DL145 server. Audience Assumptions This guide is for the person who installs, administers, and troubleshoots servers. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. Important Safety Information Before installing this product, read the Important Safety Information document included with the server. Symbols on Equipment The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions: WARNING: This symbol, in conjunction with any of the following symbols, indicates the presence of a potential hazard. The potential for injury exists if warnings are not observed. Consult your documentation for specific details. This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel. This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason. WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. This symbol on an RJ-45 receptacle indicates a network interface connection. WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle. HP ProLiant DL145 Server User Guide vii

8 About This Guide This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power. WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system. This symbol indicates that the component exceeds the recommended weight for one individual to handle safely. Weight in kg Weight in lb WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling. Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: The leveling jacks are extended to the floor. The full weight of the rack rests on the leveling jacks. The stabilizing feet are attached to the rack if it is a single-rack installation. The racks are coupled together in multiple-rack installations. Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information. IMPORTANT: Text set off in this manner presents essential information to explain a concept or complete a task. NOTE: Text set off in this manner presents additional information to emphasize or supplement important points of the main text. viii HP ProLiant DL145 Server User Guide

9 About This Guide Related Documents Getting Help For additional information on the topics covered in this guide, refer to the HP Website at or HP Servers Troubleshooting Guide HP ProLiant DL145 Maintenance and Service Guide If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations. Technical Support HP Website In North America, call the HP Technical Support Phone Center at This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. Outside North America, call the nearest HP Technical Support Phone Center. Telephone numbers for worldwide Technical Support Centers are listed on the HP website, Be sure to have the following information available before you call HP: Technical support registration number (if applicable) Product serial number Product model name and number Applicable error messages Add-on boards or hardware Third-party hardware or software Operating system type and revision level The HP website has information on this product as well as the latest drivers and flash ROM images. You can access the HP website at Authorized Reseller For the name of your nearest authorized reseller: In the United States, call In Canada, call Elsewhere, see the HP website for locations and telephone numbers. HP ProLiant DL145 Server User Guide ix

10 About This Guide Reader s Comments HP welcomes your comments on this guide. Please send your comments and suggestions by to ServerDocumentation@hp.com. x HP ProLiant DL145 Server User Guide

11 1 Server Component Identification Front Panel Components Figure 1-1: Front panel components Table 1-1: Front Panel Components Item Description Status 1 LAN activity LED On = Network link Flashing = Network link and activity Off = No link to network 2 System health LED Off = Normal On = System degraded 3 Disk drive activity LED On = Drive activity Flashing = High drive activity Off = No drive activity 4 Power LED On = Power on Off = Power off continued HP ProLiant DL145 Server User Guide 1-1

12 Server Component Identification Table 1-1: Front Panel Components continued Item Description Status 5 USB port 6 Media bay 7 Hard drive bay 2 8 Hard drive bay 1 9 Power button Rear Panel Connectors Figure 1-2: Rear panel connectors Table 1-2: Rear Panel Connectors Item Description Item Description 1 Mouse 5 Dedicated Management NIC 2 Keyboard 6 NIC 2 3 Video 7 NIC 1 4 USB 8 COM1/Management Processor 1-2 HP ProLiant DL145 Server User Guide

13 Server Component Identification Rear Panel LEDs Figure 1-3: Rear Panel LEDs Table 1-3: Rear Panel LEDs Item Description LED Color Status 1 Aux Power LED Amber On = Aux power present Off = No Aux power 2 LAN Link LED Green Green = 1 GB connection Off = no link to network Red Red = 10/100 MB connection Off = no link to network 3 LAN Activity LED Amber On or flashing = network activity Off = no network activity HP ProLiant DL145 Server User Guide 1-3

14 Server Component Identification System Board Components Figure 1-4: System board components Table 1-4: System Board Components Item Description 1 PCI-X riser board slot 2 NVRAM Battery 3 Management Processor 4 Video board 5 J9 CMOS jumper 6 Processor socket 2 7 Memory banks 2A and 2B 8 Processor power module slot 2 9 Processor power module slot 1 10 Memory banks 1A and 1B 11 Processor 1 (boot processor) 1-4 HP ProLiant DL145 Server User Guide

15 Server Component Identification J9 CMOS Jumper Figure 1-5: J9 CMOS Jumper Table 1-5: J9 CMOS Jumper Settings Item 1 Set Setting 2 Clear To clear CMOS: 1. Back up the server data. 2. Shut down the operating system as directed by the operating system documentation. 3. Press the Power button to power down the server. When the server powers down, the system power LED turns off. 4. Disconnect the power cord. 5. Set the J9 CMOS jumper to Clear and hold in position for 3 seconds. 6. Reset the J9 CMOS jumper to Set. 7. Connect the power cord. 8. Power up the system. 9. Reconfigure the server using the BIOS Setup Utility. Refer to Chapter 5, Operating System Installation and Software for more information on the BIOS Setup Utility. HP ProLiant DL145 Server User Guide 1-5

16 2 Server Operations Powering Up the Server To power up the server, press the Power button. Powering Down the Server WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed. 1. Back up the server data. 2. Shut down the operating system as directed by the operating system documentation. 3. Press the Power button to power down the server. When the server powers down, the system power LED turns off. 4. Disconnect the power cord. The system is now without power. HP ProLiant DL145 Server User Guide 2-1

17 Server Operations Extending the Server from the Rack 1. Extend the server on the rack rails until the server rail-release latches engage. Figure 2-1: Extending the server from the rack 2. Reverse the steps to restore the server to operating position. Removing the Server from the Rack Press the side rail tabs to release the server from the rack rails. Figure 2-2: Removing the server from the rack 2-2 HP ProLiant DL145 Server User Guide

18 Server Operations Removing the Access Panel and Chassis Stiffener WARNING: Pressing the Power button does not remove power from all areas of the server. Portions of the power supply and some internal circuitry remain active until the AC power cord is disconnected. WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching. CAUTION: Electrostatic discharge can damage electronic components. Properly ground yourself before beginning any installation procedure. 1. Power down the server. Refer to the Powering Down the Server section earlier in this chapter. 2. Extend the server from the rack. Refer to the Extending the Server from the Rack section earlier in this chapter. 3. Remove the access panel. Figure 2-3: Removing the access panel 4. Remove the chassis stiffener, if necessary. HP ProLiant DL145 Server User Guide 2-3

19 Server Operations Figure 2-4: Removing the chassis stiffener 5. Reverse the steps to install the chassis stiffener and the access panel. 2-4 HP ProLiant DL145 Server User Guide

20 3 Server Setup Optional Installation Services You may choose to have HP install the system. The installation service can be purchased as a Care Pack packaged service or as a customized service agreement to meet your specific requirements. Some of the Care Pack services are as follows: Hardware installation services Hardware and operating system installation for ProLiant servers Installation and start-up services for some operating systems Installation and start-up services for Insight Manager This optional hardware installation service is available in all countries where HP has a direct or indirect service presence. Service may be ordered from and directly provided by an authorized service reseller or, in the United States only, service may be ordered by calling In the United States, HP makes all the arrangements to have the system installed by qualified guaranteed service providers. For more information, refer to the HP website Rack Planning Resources The following resource information is available on rack designs and products. The Rack Builder Pro Configuration Tool and Rack Products documentation information can be found on the HP website by following the storage link on the product website. HP ProLiant DL145 Server User Guide 3-1

21 Server Setup The entire Rack Resource CD Kit ships with all HP racks. A summary of the content of each CD follows: Rack Builder Pro Configuration Tool This information helps you to simulate potential rack configurations based on your input. Rack Builder Pro provides the following information: Graphical preview of properly configured racks Site planning data, including power requirements, cooling mandates, and physical specifications Ordering information, including required components, part numbers, and appropriate quantities The Installing Rack Products video provides a visual overview of operations required for configuring a rack with rack-mountable components. It also provides the following important configuration steps: Planning the site Installing rack servers and rack options Cabling servers in a rack Coupling multiple racks The Rack Products Documentation CD enables you to view, search, and print documentation for HP racks and rack options. It also helps you set up and optimize a rack in a manner that best fits your environment. Optimum Environment When installing the server in a rack, select a location that meets the environmental standards described in the following sections. Space and Airflow Requirements To enable servicing and adequate airflow, observe the following spatial requirements when deciding where to install the rack: Leave a minimum clearance of 63.5 cm (25 in) in front of the rack. Leave a minimum clearance of 76.2 cm (30 in) in the back of the rack. Leave a minimum clearance of cm (48 in) from the back of the rack to the rear of another rack or row of racks. 3-2 HP ProLiant DL145 Server User Guide

22 Server Setup HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to enable the warm air to escape from the cabinet. CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilation openings. The 9000 and Series racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64 percent open area for ventilation. CAUTION: When using a Compaq branded 7000 Series rack, you must install the high airflow rack door insert [P/N B21 (42U) and P/N B21 (22U)] to provide proper front-to-back airflow and cooling. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors: If the 42U server rack includes closing front and rear doors, you must allow 5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 in). Temperature Requirements To ensure continued safe and reliable equipment operation, install or locate the system in a well-ventilated, climate-controlled environment. The maximum recommended ambient operating temperature (TMRA) for most server products is 35 C (95 F). The temperature in the room where the rack is located must not exceed 35 C (95 F). CAUTION: To reduce the risk of damage to the equipment when installing third-party options: Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the server or to increase the internal rack temperature beyond the maximum allowable limits. Do not exceed the manufacturer s recommended ambient operating temperature (TMRA). HP ProLiant DL145 Server User Guide 3-3

23 Server Setup Power Requirements The installation of this equipment shall be in accordance with local/regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA 75, 1992 Edition (code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option. WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over the wiring and installation requirements of your facility. CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure. When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines: The power load must be balanced between available AC supply branch circuits. The overall system AC current load must not exceed 80 percent of the branch circuit AC current rating. Do not use common outlet strips for this equipment. Provide a separate electrical circuit for the server. Grounding Requirements For proper operation and safety, the server must be properly grounded. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code) Article 250 as well as any local and regional building codes. In Canada, the equipment must be installed in accordance with Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, the installation must follow any regional or national electrical wiring codes, such as the International Electrotechnical Commission (IEC) 364, parts 1 through 7. Furthermore, you must ensure that all power distribution devices used in the installation such as branch wiring and receptacles are listed or certified groundingtype devices. Because of the high ground leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a power distribution unit (PDU) that is either permanently wired to the branch circuit of the building or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC are considered suitable for this purpose. HP does not recommend using common power outlet strips for this equipment. 3-4 HP ProLiant DL145 Server User Guide

24 Server Setup Rack Warnings and Cautions WARNING: To reduce the risk of personal injury or equipment damage, be sure that: The leveling jacks are extended to the floor. The full weight of the rack rests on the leveling jacks. The stabilizers are attached to the rack for single-rack installation. The racks are coupled together in multiple-rack installations. Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. WARNING: Always mount the heaviest item on the bottom of the rack and work from the bottom to the top. Installing Hardware Options Install any hardware options before initializing the server. For options installation information, refer to the option documentation. For server-specific information, refer to Chapter 4, Hardware Options Installation. Server Shipping Contents Unpack the server-shipping carton and locate the materials and documentation necessary for installing the server. All the rack-mounting hardware necessary for installing the server into the rack is included with the rack or the server. The contents of the server-shipping carton include: Server HP ProLiant DL145 Server Support CD Setup documentation Power cord Rack-mounting hardware HP ProLiant DL145 Server User Guide 3-5

25 Server Setup In addition to these supplied items, you may need any options to be installed. Figure 3-1: Rack-mounting hardware Table 3-1: Rack Mounting Hardware Item Description 1 Rack rail assemblies (2) 2 Bag of screws Installing the Server into the Rack If you are installing the server into a telco rack, order the appropriate option kit at the RackSolutions.com website. Follow the server specific instructions on the website to install the rack brackets. After installing the brackets, follow the steps in this section. WARNING: When installing the server in a telco rack, be sure that the rack frame is adequately secured to the top and bottom of the building structure. WARNING: Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the heaviest item first, and continue to populate the rack from the bottom to the top. 3-6 HP ProLiant DL145 Server User Guide

26 Server Setup 1. Remove server rails from rack rails. Figure 3-2: Removing server rails from rack rails 2. Attach and secure the server rails to the server. Figure 3-3: Attaching server rails HP ProLiant DL145 Server User Guide 3-7

27 Server Setup 3. Install the rack rails. Figure 3-4: Installing rack rails 4. Pull the inner slide rail forward from each rack rail assembly until it locks into place. 5. Align the server and carefully insert the server rail into the inner slide rail until the railrelease levers engage. Figure 3-5: Loading the server onto the rack rails 3-8 HP ProLiant DL145 Server User Guide

28 Server Setup 6. Slide the server into the rack and tighten the thumbscrews to secure the server. Figure 3-6: Securing the server to the rack 7. Connect peripheral devices to the server. WARNING: To reduce the risk of electric shock or fire, do not plug telecommunications/telephone connectors into the NIC connectors. IMPORTANT: To enable the embedded NIC functionality on servers running Microsoft Windows Server based operating systems, it is necessary to load the NIC drivers provided on the HP ProLiant DL145 Server Support CD. Figure 3-7: Rear panel connectors HP ProLiant DL145 Server User Guide 3-9

29 Server Setup Table 3-2: Rear Panel Connectors Item Description Item Description 1 Mouse 5 Dedicated Management NIC 2 Keyboard 6 NIC 2 3 Video 7 NIC 1 4 USB 8 COM1/Management Processor 8. Connect the power cord. 9. Power up the server and load the operating system. Operating System Installation To operate properly, the server must have a supported operating system. For the latest information on supported operating systems, refer to the HP website Install the operating system using the following instructions. 1. Use the optional DVD drive or connect a USB CD-ROM drive to a USB connector. 2. Connect a monitor to the video connector. 3. Connect a mouse to the mouse connector. 4. Connect a keyboard to the keyboard connector. 5. Place the operating system CD in the CD-ROM drive and follow the instructions to complete the server initialization process. IMPORTANT: To enable the embedded NIC functionality on servers running Microsoft Windows Server based operating systems, it is necessary to load the NIC drivers provided on the HP ProLiant DL145 Server Support CD. 6. Check the HP ProLiant DL145 Server Support CD for device drivers. The most current drivers, INF files, ROM images, and diagnostics can be downloaded from the web at Registering the Server Register the server at the HP website: HP ProLiant DL145 Server User Guide

30 Server Setup Routine Maintenance The HP ProLiant DL145 Server Maintenance and Service Guide provides specific information required for general maintenance and component replacement, including: Spare part numbers Removal and replacement procedures Diagnostic tools The HP ProLiant DL145 Server Maintenance and Service Guide can be accessed through the HP website at or at HP ProLiant DL145 Server User Guide 3-11

31 4 Hardware Options Installation If more than one option is being installed, read the installation instructions for all of the hardware options and identify similar steps to streamline the installation process. The following warnings apply to all procedures: WARNING: To reduce the risk of personal injury from surfaces, allow the drives and internal system components to cool before touching them. CAUTION: To prevent damage to electric components, properly ground server before beginning any installation procedure. Improper grounding can cause electrostatic discharge. Processors The server supports up to two processors. CAUTION: Processor socket 1 and processor power module (PPM) slot 1 must be populated at all times or the server will not function properly. CAUTION: If upgrading processor speed, update the system ROM before installing the processor. IMPORTANT: Mixing processor speeds and cache sizes is not supported. To install a processor and PPM: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the chassis stiffener. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. HP ProLiant DL145 Server User Guide 4-1

32 Hardware Options Installation 5. Remove the processor air baffle. Figure 4-1: Removing processor air baffle 6. Remove the processor blank. Figure 4-2: Removing processor blank 7. Open the processor socket lever. 8. Align the processor. 4-2 HP ProLiant DL145 Server User Guide

33 Hardware Options Installation 9. Install the processor. Figure 4-3: Installing a processor 10. Close the processor socket lever. 11. Remove the clear protective cover from the heatsink to expose the thermal pad. 12. Install the processor heatsink. Figure 4-4: Installing processor heatsink HP ProLiant DL145 Server User Guide 4-3

34 Hardware Options Installation 13. Install the PPM. Figure 4-5: Installing a PPM 14. Reinstall the access panel. 15. Restore the server to its operating position in the rack. 16. Power up the server. NOTE: The ROM sets the processing frequency during the Power-On Self-Test (POST). Memory Options Memory Guidelines The server provides double data rate (DDR) synchronous dynamic RAM (SDRAM) that can improve memory clock speed to at least 333 MHz. It activates output on both the rising and falling edge of the system clock rather than on just the rising edge, potentially doubling output. The server features the following advanced memory technologies: Support for up to 16 GB of industry-standard PC2700 registered ECC DDR SDRAM memory Advanced ECC memory for single-bit detection and multi-bit memory error correction Dual-channel memory architecture Bank 1A must always be populated. DIMMs must be installed in pairs and starting at the bank closest to the processor. All DIMMs in a bank must have the same part number. DIMMs on different banks can be of different sizes. Processor 2 must be installed before banks 2A and 2B are populated. If processor 2 is installed, it is recommended that bank 2A be populated before populating bank 1B. 4-4 HP ProLiant DL145 Server User Guide

35 Hardware Options Installation Figure 4-6: DIMM slots Table 4-1: DIMM and Processor locations Item Description Bank 1 DIMM slot 4 Bank 1B 2 DIMM slot 3 Bank 1B 3 DIMM slot 2 Bank 1A 4 DIMM slot 1 Bank 1A 5 Processor socket 1 6 Processor socket 2 7 DIMM slot 1 Bank 2A 8 DIMM slot 2 Bank 2A 9 DIMM slot 3 Bank 2B 10 DIMM slot 4 Bank 2B To install DIMMs: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. HP ProLiant DL145 Server User Guide 4-5

36 Hardware Options Installation 4. Install the DIMMs. Figure 4-7: Installing a DIMM 5. Reinstall the access panel. 6. Restore the server to its operating position in the rack. 7. Power up the server. Removing a Media Bay Blank or a DVD Drive To remove a media bay blank or a DVD drive: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the chassis stiffener. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. NOTE: If only one IDE drive is being removed and only one SCSI drive is being installed, proceed to step HP ProLiant DL145 Server User Guide

37 Hardware Options Installation 5. Disconnect the DVD drive media cable if the option is installed. Figure 4-8: Disconnecting the DVD drive media cable 6. Disconnect the DVD drive power cable if the option is installed Figure 4-9: Disconnecting the DVD drive power cable HP ProLiant DL145 Server User Guide 4-7

38 Hardware Options Installation 7. Remove the retainer clip Figure 4-10: Removing the retainer clip 8. Remove the DVD drive or media blank. Figure 4-11: Removing the DVD drive or media blank Installing a DVD Drive To install a DVD drive: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the chassis stiffener. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4-8 HP ProLiant DL145 Server User Guide

39 Hardware Options Installation 5. Remove the media bay blank. Refer to the Removing a Media Bay Blank or a DVD Drive section earlier in this chapter. 6. Insert the DVD drive into the media bay. Figure 4-12: Inserting a DVD drive 7. Install the retainer clip. Figure 4-13: Installing the retainer clip HP ProLiant DL145 Server User Guide 4-9

40 Hardware Options Installation 8. Connect the power cable to the DVD drive. Figure 4-14: Connecting the power cable 9. Connect the data cable to the DVD drive. Figure 4-15: Connecting the data cable 10. Reinstall the chassis stiffener. 11. Reinstall the access panel. 12. Restore the server to its operating position in the rack. 13. Power up the server HP ProLiant DL145 Server User Guide

41 Hardware Options Installation EIDE Hard Drive Installation The server supports up to two hard drives. To install a hard drive: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the chassis stiffener. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 5. Remove the DVD drive or media bay blank. Refer to the Installing a DVD Drive section earlier in this chapter. 6. Remove the drive tray. To locate the drive tray, refer to Server Component Identification in Chapter 1. Figure 4-16: Removing the drive tray HP ProLiant DL145 Server User Guide 4-11

42 Hardware Options Installation 7. Install the drive in the drive tray. Figure 4-17: Installing a drive in the drive tray 8. Connect the power and data cables to the hard drive. Figure 4-18: Connecting the cables to the hard drive 4-12 HP ProLiant DL145 Server User Guide

43 Hardware Options Installation 9. Secure the drive cage. Figure 4-19: Securing the drive cage 10. Install the DVD drive or media bay blank. 11. Reinstall the chassis stiffener. 12. Reinstall the access panel. 13. Restore the server to its operating position in the rack. 14. Power up the server. Removing the EIDE Hard Drives All references to left and right drives are from the front of the server. NOTE: If two SCSI drives are to be installed, only remove the right drive. To remove the EIDE hard drives: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the chassis stiffener. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. HP ProLiant DL145 Server User Guide 4-13

44 Hardware Options Installation 5. Disconnect and remove the left IDE drive. Figure 4-20: Removing the left drive tray NOTE: If there is no drive installed in the right drive, process to the SCSI Hard Drive Installation section later in this chapter.. 6. Remove the screw from the right drive tray. Figure 4-21: Removing the screw from right drive tray 7. Disconnect the cable and remove the drive HP ProLiant DL145 Server User Guide

45 Hardware Options Installation Figure 4-22: Disconnecting the cable and removing the drive 8. Remove the drives from the drive trays. Figure 4-23: Removing the drives from the drive tray HP ProLiant DL145 Server User Guide 4-15

46 Hardware Options Installation PCI-X Expansion Board The server has one PCI-X expansion slot. CAUTION: To avoid risk of damage to the system or expansion board, remove the AC power cord before installing or removing an expansion board. With the front panel Power button in the off position, auxiliary power is still connected to the expansion slot and may damage the board. To install an expansion board: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the PCI-X riser cage. Figure 4-24: Removing the PCI-X riser cage 4-16 HP ProLiant DL145 Server User Guide

47 Hardware Options Installation 5. Remove the expansion slot cover. Figure 4-25: Removing the expansion slot cover 6. Install the expansion board in the slot and secure. Figure 4-26: Installing an expansion board HP ProLiant DL145 Server User Guide 4-17

48 Hardware Options Installation 7. Install the PCI-X riser cage. Figure 4-27: Installing the PCI-X riser cage 8. Connect any required cables to the expansion board. 9. Reinstall the access panel. 10. Restore the server to its operating position in the rack. 11. Power up the server. SCSI Hard Drive Installation To prepare the server for SCSI hard drive installation, perform the following steps: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 4. Remove the chassis stiffener. Refer to Removing the Access Panel and the Chassis Stiffener in Chapter 2, Server Operations. 5. Remove the EIDE hard drives. Refer to Removing the EIDE Hard Drives section earlier in this chapter HP ProLiant DL145 Server User Guide

49 Hardware Options Installation Installing the SCSI Drives To install SCSI drives: 1. Set the left drive SCSI address 0. NOTE: See the documentation that ships with the drive for information on how to set the SCSI address. 2. Mount the SCSI drive on the drive tray. Figure 4-28: Mounting the first SCSI drive IMPORTANT: Route the cable through drive bay one (the left drive bay) before connecting the SCSI cable to the SCSI drive. NOTE: Verify connector orientation before attaching 3. Connect the left SCSI connector to the SCSI drive. Figure 4-29: Connecting SCSI connector HP ProLiant DL145 Server User Guide 4-19

50 Hardware Options Installation 4. Insert the drive, connect the power cable, and secure the drive. Figure 4-30: Securing the first SCSI drive NOTE: If installing only one drive, proceed to the Installing the SCSI controller section. IMPORTANT: When installing a SCSI device in the left drive, always connect the short power cable. 5. Set the right drive SCSI address to Mount the SCSI drive on the drive tray. Figure 4-31: Mounting the second SCSI drive NOTE: Verify connector orientation before attaching HP ProLiant DL145 Server User Guide

51 Hardware Options Installation 7. Install the drive and connect the power cable and the terminated end of the SCSI cable (the SCSI connector nearest the terminator). Figure 4-32: Connecting power and media cables to the second SCSI drive 8. Secure the drive. Figure 4-33: Securing the second SCSI drive HP ProLiant DL145 Server User Guide 4-21

52 Hardware Options Installation Installing the SCSI Controller To install the SCSI controller: 1. Remove the PCI-X riser cage. Figure 4-34: Removing the PCI-X riser cage 2. Remove the slot blank. Figure 4-35: Removing the slot blank 4-22 HP ProLiant DL145 Server User Guide

53 Hardware Options Installation 3. Install the SCSI controller. Figure 4-36: Installing the SCSI controller 4. Install the PCI-X riser cage Routing the SCSI Cable To route the SCSI cable: 1. Disconnect the power supply cable. Figure 4-37: Disconnecting the power supply cable 2. Route the SCSI cable in the following manner: a. Around the power supply b. Over the power supply connector ensuring that there is a gap between the cable and the fans CAUTION: When routing the SCSI cable in the gap between the power supply and the PCI-X riser cage, ensure that the SCSI cable is flat across the gap so as not to interfere with proper airflow. HP ProLiant DL145 Server User Guide 4-23

54 Hardware Options Installation CAUTION: When routing the SCSI cable, always be sure that the cable is not in a position where it can be pinched or crimped by the access panel. Figure 4-38: Routing the SCSI cable around the power supply 3. Connect the SCSI cable to the SCSI controller. Figure 4-39: Connecting the SCSI cable to the SCSI controller 4. Reconnect the power supply cable. 5. Install the chassis stiffener. 6. Install the access panel. The installation is complete HP ProLiant DL145 Server User Guide

55 Hardware Options Installation Additional Information For additional information regarding the drivers, documentation, product information, or specifications for the Dual Channel ultra320 SCSI Host Bus Adaptor, refer to the following website: NOTE: Not all features of the Dual Channel ultra320 SCSI Host Bus Adaptor are supported by this server. For additional information on the supported features, refer to the HP ProLiant DL145 Server User Guide at Supported Features The Dual Channel ultra320 SCSI Host Bus Adaptor supports the following features: Internal channel HP ProLiant DL145 Server User Guide 4-25

56 Operating System Installation and Software 5 Overview This chapter discusses the following topics: Operating System Installation HP ProLiant DL145 Server Support CD PXE Deployment Software and Utilities ROMPaq Utility Management Processor Flash Utility Diagnostics Utility BIOS Setup Utility Server Management Configuring the Serial Port Configuring Access Through the Serial Port Configuring Access Through the Network User Accounts Accessing the Management Processor CLI Using CLI Commands BIOS Console Text Redirection Linux Operating System Redirection Windows EMS Management Using the Watch Dog Timer System Event Log Systems Insight Manager IPMI System Management HP ProLiant DL145 Server User Guide 5-1

57 Operating System Installation and Software Operating System Installation To operate properly, the server must have a supported operating system. For the latest information on supported operating systems, refer to the HP website: Install the operating system using the following instructions. 1. Use the optional DVD drive or connect a USB CD-ROM drive to a USB connector. 2. Connect a monitor to the video connector. 3. Connect a mouse to the mouse connector. 4. Connect a keyboard to the keyboard connector. 5. Place the operating system CD in the CD-ROM drive and follow the instructions to complete the server initialization process. IMPORTANT: To enable the embedded NIC functionality on servers running Microsoft Windows Server based operating systems, it is necessary to load the NIC drivers provided on the HP ProLiant DL145 Support CD. 6. Check the HP ProLiant DL145 Server Support CD for device drivers. The most current drivers, INF files, ROM images, and diagnostics can be downloaded from the web at ProLiant DL145 Support CD The HP ProLiant DL145 Server Support CD contains the following drivers: For Microsoft Windows Server 2003 AMD-8131 Hyper Transport IOAPIC Controller AMD-8111 High Precision Event Timer Broadcom NetXtreme Gigabit Ethernet NIC Driver for Windows 2003 For Microsoft Windows 2000 AMD-8131 Hyper Transport IOAPIC Controller AMD-8111 High Precision Event Timer AMD-8111 System Management Controller Broadcom NetXtreme Gigabit Ethernet NIC Driver for Windows HP ProLiant DL145 Server User Guide

58 Operating System Installation and Software PXE Deployment Preboot execution environment (PXE) is a component of the Intel Wired for Management (WfM) specification. This feature enables a user to configure a server and install an operating system over a network. To deploy an operating system to multiple servers, you can install a PXE deployment server on a network. Servers to be deployed then load an image over the network from the PXE server and execute it in memory. For each server that you are deploying, the PXE server must be connected to the NIC designated for PXE. A number of third-party PXE deployment tools are available for Windows and Linux. For additional information refer to ftp.compaq.com/pub/products/servers/management/pxe_wp.pdf When a PXE-enabled client boots, it obtains an IP address from a dynamic host configuration protocol (DHCP) server. The client obtains the name of the Network Boot Program (NBP) from the appropriate boot server. Then, the client uses trivial file transfer protocol (TFTP) to download the NBP from the boot server and executes the image. Software and Utilities ROMPaq Utility This section provides information about the following utilities and support tools. ROMPaq Utility Management Processor Flash Utility Diagnostics Utility BIOS Setup Utility Download the most current versions of these utilities and instructions at ROM flash enables you to upgrade the firmware (BIOS). To upgrade the BIOS: 1. Download the latest ROMPaq at 2. Follow the instructions and create a ROMPaq bootable diskette. 3. Connect a USB diskette drive to the server. 4. Insert the ROMPaq bootable diskette. 5. Power the server off and then on. When prompted, press the F10 key to enter the Setup Utility. HP ProLiant DL145 Server User Guide 5-3

59 Operating System Installation and Software 6. Navigate to the Boot Settings screen and select Boot Device Priority. Verify that the diskette drive is set as the 1 st Boot Drive. 7. Exit setup and restart. 8. Boot server from the ROMPaq bootable diskette you created in step 2. The ROMPaq Utility checks the system and provides a choice (if more than one exists) of available ROM versions. The default ROM version is the latest. After ROMPaq has finished flashing the ROM, it may be necessary to restore default values. Management Processor Flash Utility Diagnostics Utility To update the Management Processor firmware, download the Management Processor Flash Utility and follow the instructions that come with the firmware. The firmware can be downloaded at The HP Insight Diagnostics Utility is available for the ProLiant DL145 server. To run this utility: 1. Download the latest diagnostics utility at 2. Follow the instructions and create a bootable diskette. 5-4 HP ProLiant DL145 Server User Guide

60 Operating System Installation and Software BIOS Setup Utility Starting Setup Utility NOTE: The BIOS Setup Utility is not required in the initial setup of the server. The default BIOS settings should be adequate. The options in this utility are meant to assist with specific configuration issues. This section describes the BIOS Setup Utility, which is used to change the server configuration defaults. You can run the utility with or without an operating system present on the server. Setup stores most of the configuration values in battery-backed CMOS and the rest in flash memory. The values take effect when you boot the server. The BIOS uses these values to configure the hardware. If selected values and the hardware do not agree, POST generates an error message and you must then run Setup to specify the correct configuration. Run Setup to view or modify such server features as: Configuring system devices and installed options Viewing system information Selecting the boot device and boot priority NOTE: Features and settings available in the BIOS Setup Utility can change with updated ROM releases. If the server's actual BIOS Setup Utility screens differ from this documentation then it is recommended to upgrade to the latest ROM release and download the latest user guide from To start Setup during the power-on sequence, follow these steps: 1. Press the power on/off button on the front panel of the server. 2. When POST shows the message Press <F10> if you want to run SETUP, press the F10 key. If the server has an administrator password configured, the system prompts you to enter the password. If the server does not have a password configured, the main screen of the BIOS Setup Utility appears. Recording Your Setup Settings Before you make any changes, record the current values. If the default values need to be restored later, such as after a CMOS clear, you must run Setup again. Referring to recorded original settings could make your task easier. HP ProLiant DL145 Server User Guide 5-5

61 Operating System Installation and Software Navigating Setup Utility Screens The BIOS Setup Utility consists of five primary menus (not all BIOS menus are covered in the guide): Main: Displays details on BIOS, processor and System Memory, and lets you configure the system time and date. Advanced: Lets you configure peripheral devices and remote access and disable USB information. Boot: Lets you configure Boot settings. Security: Lets you set a password. Exit: Exits the utility with or without saving utilities and allows management of custom settings. Each menu occupies a single screen and presents a list of menu items. Some menu items are submenus, while others are settings that you can change from the screen. Table 5-1 describes how to navigate between the utility screens and menus. Table 5-1: Setup Screen Navigation Press ENTER TAB F9 F10 ESC To Scroll left through the main menu screens. Scroll right through the main menu screens. Select a submenu item or accept a drop-down choice. Select a field within a value (for example, date field). Select the default value. Save changes and exit Setup. Go back to a previous screen. Scroll up through menu items or value lists. Scroll down through menu items or value lists. 5-6 HP ProLiant DL145 Server User Guide

62 Operating System Installation and Software Setup Screens Main Table 5-2 describes the menu items available on the Main screen. Default values are shown. Table 5-2: BIOS Setup Main Screen Menu Items Primary Menu Item AMIBIOS Processor Sub Menu Items Version Build Date ID Type Speed Count Default Value N/A N/A N/A N/A N/A N/A Description The currently loaded AMIBIOS information. You cannot change these values. They appear for informational purposes only. The currently loaded processor information. You cannot change these values. They appear for informational purposes only. System Memory Size N/A The currently loaded system memory. You cannot change this value. It appears for informational purposes only. System Serial ID (10-digit number) You cannot change this value. It appears for informational purposes only. NIC 1 MAC Address NIC 2 MAC Address Asset Tag ID N/A Enter an asset tag to track the server. System Time HH:MM:SS Set the System Time in hour:minute:second format. System Date MM/DD/YYYY Set the System Date in month/day/year format. HP ProLiant DL145 Server User Guide 5-7

63 Operating System Installation and Software Advanced Table 5-3 describes the menu items available on the Advanced screen. Seven menu items exist on this screen. Each of these items contains submenus that in turn can also lead to subsequent submenus. Default values are shown. Table 5-3: BIOS Setup Advanced Screen Menu Items Primary Menu Item IDE Configuration EMS Console Configuration Event Log Control Sub Menu Items Default Value Comments OnBoard PCI IDE Controller Primary IDE Master Primary IDE Slave Secondary IDE Master Secondary IDE Slave Both N/A N/A N/A N/A You cannot change these values. They appear for informational purposes only EMS Remote Console Disabled This option must be enabled for Windows EMS management. For more information, refer to Windows EMS Management in this chapter. Serial Port Address COM1 Serial Baud Rate 9600, 8, n, 1 Terminal Type View Event Log Mark all events as read Clear Event Log Event Log Statistics VT100 continued 5-8 HP ProLiant DL145 Server User Guide

64 Operating System Installation and Software Table 5-3: BIOS Setup Advanced Screen Menu Items continued Primary Menu Item Management Processor Configuration BIOS Serial Console Configuration USB Configuration Sub Menu Items Default Value Comments Management Processor Status Clear Management Processor Event Log View Management Processor Event Log Set Serial Port Sharing Set LAN Configuration Shared Not Shared Refer to the Server Management section in this chapter. Refer to the Server Management section in this chapter. See Table 5-4, LAN Configuration Settings, immediately following this table. Set PEF Configuration Disabled HP recommends this default setting. Refer to the third-party IPMI Utilities for further instructions. Watch Dog Timer Action Disabled Allows the Management Processor to reset or power down the system if the operating systems crashes or hangs. BIOS Serial Console Enabled This option must be enabled for BIOS redirection. For more information, refer to BIOS Console Text Redirection in this chapter. Serial Port Address COM1 Serial Baud Rate 9600, 8, n, 1 Flow Control Redirection after BIOS POST Terminal Type Send Carriage Return Module Version USB Devices Enabled USB Host Controllers Legacy USB Support None Disabled VT100 Enabled None Enabled Enabled HP ProLiant DL145 Server User Guide 5-9

65 Operating System Installation and Software Table 5-4: LAN Configuration Settings Primary Menu Item Default Value Comments LAN Configuration Settings Channel Number 02 NOTE: The default number needs to be changed to 02. Once changed, you will not need to change it again. IP Address MAC address Subnet Mask IP address assigned as static or DHCP, as needs require. See the note below for more information. HP recommends no change to the default settings. A Subnet Mask is required for static IP configuration. See the note below for more information. NOTE: A static IP address is automatically assigned permanently (and manually) to a computer in a TCP/IP network environment. Static IP addresses are usually assigned to networked devices that are consistently accessed by multiple users, such as printers, faxes, or server computers. A dynamic IP address is automatically assigned to a client station (computer, printer, etc.) in a TCP/IP network environment. Dynamic IP addresses are typically assigned by a DHCP server, which can be a network computer or another piece of hardware. A dynamic IP address may change every time your computer connects to the network HP ProLiant DL145 Server User Guide

66 Operating System Installation and Software Boot Table 5-5 describes the menu items available on the Boot screen. Seven menu items exist on this screen. Each of these items contains submenus that in turn can also lead to subsequent submenus. Default values are shown. NOTE: Setting wrong values in submenus below may cause the system to malfunction. Table 5-5: BIOS Setup Boot Screen Menu Items Primary Menu Item Sub Menu Items Default Value Description Boot Settings Configuration Quick Boot Enabled Bootup Num-Lock On Select power-on state for NumLock. Boot Device Priority Hard Disk Drives ATAPI CDROM Drives PS/2 Mouse Support Enabled Typematic Rate Fast Select keyboard typematic rate. Wait for F1 if Error Disabled Wait for F1 key to be pressed if error occurs. Restore on AC/Power Loss Last State Absent Keyboard Error Warning Information only Onboard NIC Onboard NIC PXE Option ROM 1 st Boot Device 2 nd Boot Device Enabled Enabled 3 rd Boot Device Broadcom MBA 4 th Boot Device Broadcom MBA 1 st Drive PM-Maxtor 6Y080L0 Specifies the boot device priority sequence Information only 1 st Drive SS-DV-28E-B Information only HP ProLiant DL145 Server User Guide 5-11

67 Operating System Installation and Software Security Table 5-6 describes the menu items available on the Security screen. Table 5-6: BIOS Setup Security Screen Menu Items Menu Item Default Value Description Supervisor Password Not installed User Password Not installed Change Supervisor Password Enter Install or change the password. Change User Password Enter Install or change the password. Clear User Password Enter Immediately clears the user password. Boot Sector Virus Protection Disabled Exit Table 5-7 describes the menu items available on the Exit screen. Table 5-7: BIOS Setup Exit Screen Menu Items Menu Item Save Changes and Exit Discard Changes and Exit Discard Changes Restore Default Values Description Exit system setup after saving the changes. The F10 key can be used for this operation. Exit system setup without saving any change. The ESC key can be used for this operation. Discards changes done so far to any of the setup questions. The F7 key can be used for this operation. Restore default values for all setup questions. The F9 key can be used for this operation HP ProLiant DL145 Server User Guide

68 Operating System Installation and Software Server Management The ProLiant DL145 server includes remote management features that are critical for use in high performance computing environments. The ProLiant DL145 server contains an integrated ProLiant 100-series Management Processor that operates independently from the operating system and is powered from auxiliary power. It provides system administrators with access to the server at any time, even prior to an operating system being installed on the server. This Management Processor provides a text remote console and a command line interface (CLI), with two methods of access. Connection to the Management Processor can occur through: Serial port (for use with terminal emulation software or with existing serial infrastructure) Dedicated Management NIC (TCP/IP access over the network using any standard Telnet utility) Both of these industry-standard methods allow access to the management features of the ProLiant DL145 server. In addition, the ProLiant 100-series Management Processor is Intelligent Platform Management Interface (IPMI) v1.5 compliant. Configuring the Serial Port The serial port can be configured to work in two different ways: Shared The server uses the serial port as a regular system serial port and the serial port can be used to communicate with the Management Processor using terminal emulation software or through an existing serial infrastructure. Not Shared The server uses the serial port as a regular system serial port, but the serial port is not used to communicate with the Management Processor. NOTE: Some devices connected to the server serial port may operate with limitations, particularly those devices that rapidly change serial port settings. To configure the serial port: 1. Start Setup during the power-on sequence. a. Power on the server by pressing the power on/off button on the front panel. b. When POST shows the message Press <F10> if you want to run SETUP, press the F10 key. If the server has an administrator password configured, the system prompts you to enter the password. If the server does not have a password configured, the main screen of the BIOS Setup Utility appears. 2. Press to navigate to the Advanced menu. 3. Press to scroll to the Management Processor Configuration menu. Press the Enter key. 4. Press to scroll to the Serial Port Sharing option. HP ProLiant DL145 Server User Guide 5-13

69 Operating System Installation and Software 5. Do one of the following: Press + or to toggle the setting between Shared and Not Shared. Press the Enter key to select the appropriate option. Press the Enter key. The Options box appears. Press or to select Shared with BMC or Not shared W/BMC. Press the Enter key to select the appropriate option. 6. Press the Esc key to return to the previous screen or press the F10 key to save the changes and exit Setup. Configuring Access Through the Serial Port The server is connected to a COM port of a host computer using a null modem cable. Through this connection, you can access the Management Processor CLI, verify POST remotely, access the BIOS Setup Utility remotely, and access the text-mode operating system consoles for Windows 2003 (EMS) or Linux. Connect the serial port to an existing serial infrastructure or use a terminal emulation session to manage the server using the serial port. To set up a terminal emulation session: 1. Connect a null modem cable between the serial port on the server rear panel and a COM port on the host computer. 2. Verify that the server serial port is configured to Shared. For detailed instructions, refer to Configuring the Serial Port in this chapter. 3. Launch a terminal emulation program, such as HyperTerminal. NOTE: HyperTerminal is the remote communication program provided with Windows and is used in this section as an example for setting up a terminal emulation session. HyperTerminal can be launched by clicking Start>Programs>Accessories>HyperTerminal. If you are using another utility, the steps may be different. The Connection Description window appears HP ProLiant DL145 Server User Guide

70 Operating System Installation and Software 4. Enter a name for the connection, select an icon, and click OK. The Connect To window appears. 5. Select the COM port on the host computer to which the serial cable is connected. Click OK. The COM Properties window appears. HP ProLiant DL145 Server User Guide 5-15

71 Operating System Installation and Software 6. Select the following port settings, then click OK. Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None The HyperTerminal session activates. NOTE: No information appears unless the EMS Remote Console or BIOS Serial Console option is set to Enabled on the Setup Utility Advanced screen HP ProLiant DL145 Server User Guide

72 Operating System Installation and Software Configuring Access Through the Network The server is connected to the network using a standard Ethernet cable. Through this connection, you can access the Management Processor CLI, verify POST remotely, and access the BIOS Setup Utility remotely. To set up a Telnet session: 1. Connect a standard Ethernet cable between the dedicated Management NIC on the server rear panel and a network jack. The Management Processor automatically negotiates an IP address. 2. Verify the IP address: a. Establish serial communication to the server. Refer to Configuring Access Through the Serial Port in this chapter. b. Log in to the Management Processor CLI. The ProLiant> prompt appears. Refer to Logging Into the Management Processor Command Line Interface in this chapter. IMPORTANT: You must log in as an OEM or Administrator level user. For information on user accounts, refer to User Accounts in this chapter. c. Enter the network setup command. The INET> prompt appears. d. Enter the state command. The Management Processor IP address appears. e. Exit network setup by entering the quit command. The ProLiant> prompt appears. f. Exit the Management Processor CLI. Refer to Logging Out of the Management Processor CLI in this chapter. 3. Launch Telnet by entering the following command at a DOS prompt or the command line: Telnet xxx.xxx.xxx.xxx where xxx.xxx.xxx.xxx is the Management Processor IP address. User Accounts The Management Processor supports four user accounts. Use third-party IPMI software to configure usernames and privileges. Usernames and passwords are case-sensitive and can contain up to 16 characters each. The default accounts include: OEM OEM privileges allow the user to execute the full set of CLI commands described in Table 5-8. The default username/password is OEM/OEM. NOTE: The default maximum privilege level for the serial channel is OEM. This default is allowed since physical security occurs with the RS-232 interface. If a serial terminal is connected to the RS-232 interface, the serial terminal can provide additional security measures. Administrator Administrator privileges allow the user to execute the full set of CLI commands described in Table 5-8. The default username/password is admin/admin. HP ProLiant DL145 Server User Guide 5-17

73 Operating System Installation and Software Operator Operator privileges allow the user to: Run IPMI commands from the CLI. Read the Sensor Data Records Log. Read the System Event Log. The default username/password is Operator/Operator. User User privileges allow the user to run IPMI commands. The default username and password are blank. NOTE: The default maximum privilege level for the LAN channel is User level. Use third-party IPMI software to set the access and the user privilege for the channel if more privileges are needed. Accessing the Management Processor CLI Through either serial or Telnet access, the ProLiant 100-series Management Processor provides system administrators with the capability to: Freely switch between remote console (Console Mode) and the Management Processor CLI (Terminal Mode). Remotely power on and off the server. Perform warm or cold server reboots. Configure TCP/IP settings for the dedicated Management NIC. Change user passwords. Issue raw IPMI v1.5 commands. Access command line help HP ProLiant DL145 Server User Guide

74 Operating System Installation and Software Logging Into the Management Processor Command Line Interface To log into the Management Processor CLI and enter Terminal mode: 1. Establish a connection to the server by doing one of the following: Establish serial communication to the server as described in Configuring Access Through the Serial Port in this chapter. Launch a Telnet session as described in Configuring Access Through the Network in this chapter. 2. Press the Shift+Esc+9 keys. The Management Processor CLI appears. 3. Enter the username at the login: prompt. 4. Enter the password at the password: prompt. NOTE: The default usernames and passwords are: OEM/OEM admin/admin Operator/Operator <null>/<null> Privileges for the different accounts are discussed in User Accounts in this chapter. The ProLiant> prompt appears. Logging Out of the Management Processor CLI To exit the Management Processor CLI and enter Console mode, do one of the following: Press the Shift+Esc+Q keys. Enter the quit command at the ProLiant> prompt. HP ProLiant DL145 Server User Guide 5-19

75 Operating System Installation and Software Using CLI Commands CLI commands are entered at the ProLiant> prompt that appears after a successful login to the Management Processor. For more information on logging in to the Management Processor, refer to Logging In to the Management Processor CLI in this chapter. Table 5-8 lists and describes the CLI commands. The commands are described in further detail in the sections that follow. IMPORTANT: CLI commands are case-sensitive. Table 5-8: Basic CLI Commands Command changepassword power on power off ipmicommand command, where command is a supported IPMI command sdrread selread network setup* reset warm reset cold help quit Description Change the password. Power on the server remotely. Power off the server remotely. Execute an IPMI command. Display the sensor data records. Display the System Event Log. Set up the network. Reset the server. Power off the server and reset the server after a short time has passed. Display a list of commands. Log out of the Management Processor. * Entering network setup to configure the network results in the prompt changing from ProLiant> to INET>. For information on additional commands that can be entered at the INET> prompt, refer to Setting Up the Network in this chapter HP ProLiant DL145 Server User Guide

76 Operating System Installation and Software Changing Passwords Passwords are stored in nonvolatile memory and can be changed through IPMI commands. Administrator and OEM level users can change passwords through the Management Processor CLI: 1. Log in to the Management Processor CLI as described in Logging In to the Management Processor CLI in this chapter. 2. At the ProLiant> prompt, enter changepassword. 3. Enter the current password when prompted. 4. Enter the new password when prompted. NOTE: Passwords are case-sensitive and can contain up to 16 characters. 5. Re-enter the new password when prompted. Powering the Server On and Off and Resetting the Server Remotely Using the CLI, Administrator and OEM level users can remotely operate the power button of a host server. Virtual power support allows the user to power on, power off, and power cycle the host server. This virtual power support is independent of the operating system and functions regardless of the state of the operating system. 1. Log in to the Management Processor CLI as described in Logging In to the Management Processor CLI in this chapter. 2. At the ProLiant> prompt, enter one of the following commands. power on Powers on the server power off Power off the server reset warm Resets the server reset cold Powers off the server and resets the server after a short time has elapsed HP ProLiant DL145 Server User Guide 5-21

77 Operating System Installation and Software Setting Up the Network Administrator and OEM level users can configure the network settings for the Management Processor. To configure the settings: 1. Log in to the Management Processor CLI as described in Logging In to the Management Processor CLI in this chapter. 2. At the ProLiant> prompt, enter network setup. The INET> prompt appears. 3. Enter any Management Processor network setup command. The available commands are described in Table 5-9. IMPORTANT: CLI commands are case-sensitive. Table 5-9: Network Setup Commands Command state delay host length rtadd rtdel routes setip xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy, where xxx.xxx.xxx.xxx is the IP address and yyy.yyy.yyy.yyy is the subnet mask setdgw dhcp firewall setfirewall quit help help general help diagnostics help telnet Description Display the current setup information. Set the milliseconds to wait between pings. Set the default active IP host. Set the default ping packet length. Manually add an IP route to the table. Manually delete an IP route from the table. Display the IP route table. Set the Management Processor IP address and subnet mask. Set the Management Processor default gateway. Enable or Disable DHCP. Display the current firewall settings. Set the firewall parameters. Quit network setup. Display menu help. Display menu help. Display diagnostic commands. Display Telnet commands HP ProLiant DL145 Server User Guide

78 Operating System Installation and Software Entering IPMI Commands Users with any account privilege can enter IPMI commands at the Management Processor CLI. To enter IPMI commands: 1. Log in to the Management Processor CLI as described in Logging In to the Management Processor CLI in this chapter. 2. At the ProLiant> prompt, enter ipmicommand command, where command is a supported IPMI command. BIOS Console Text Redirection BIOS console text redirection functionality enables administrators to monitor the entire boot process remotely and make changes in the BIOS Setup Utility from a remote computer. To configure BIOS console text redirection: 1. Start Setup during the power-on sequence. a. Power on the server by pressing the power on/off button on the front panel. b. When POST shows the message Press <F10> if you want to run SETUP, press the F10 key. If the server has an administrator password configured, the system prompts you to enter the password. If the server does not have a password configured, the main screen of the BIOS Setup Utility appears. 2. Press to navigate to the Advanced menu. 3. Press to scroll to the BIOS Serial Console Configuration menu. Press the Enter key. 4. Press to scroll to the BIOS Serial Console option. 5. Do one of the following: Press + to toggle the setting to Enabled. Press the Enter key. The Options box appears. Press or to select Enabled. Press the Enter key. 6. Press the Esc key to return to the previous screen or press the F10 key to save the changes and exit Setup. To view POST and enter the BIOS Setup Utility remotely: 1. Establish a connection to the server by doing one of the following: Establish serial communication to the server as described in Configuring Access Through the Serial Port in this chapter. Launch a Telnet session as described in Configuring Access Through the Network in this chapter. 2. Reboot the server. As the server boots, POST displays on the remote computer monitor. HP ProLiant DL145 Server User Guide 5-23

79 Operating System Installation and Software 3. When POST shows the message Press <F10> if you want to run SETUP, press the ESC+4 keys on the remote keyboard. If the server has an administrator password configured, the system prompts you to enter the password. If the server does not have a password configured, the main screen of the BIOS Setup Utility appears. To configure redirection after BIOS POST: 1. In the BIOS Setup Utility, press to navigate to the Advanced menu. 2. Press to scroll to the BIOS Serial Console Configuration menu. Press the Enter key. 3. Press to scroll to the Redirection after BIOS POST option. 4. Do one of the following: Press + or - to toggle the settings. Press the Enter key. The Options box appears. Press or to select the appropriate setting. Press the Enter key to select the appropriate option. The available options include: Disabled Turns off the redirection after POST Boot Loader Redirection is active during POST and Boot Loader Always Redirection is always active. 5. Press the Esc key to return to the previous screen or press the F10 key to save the changes and exit Setup. Linux Operating System Redirection Linux operating systems provide text-based console access from the serial port. The Management Processor supports operating system redirection so that an administrator can connect the server serial port to the existing serial infrastructure and perform basic management tasks. Windows EMS Management Windows Server 2003 provides text-based console access from the serial port. An administrator can connect a laptop to the serial port and perform basic management tasks. The Windows Emergency Management Services (EMS) Console, if enabled, displays the processes that are running and allows administrators to halt processes. This capability can be important in cases where video, device drivers, or other operating system features have prevented normal operation and normal corrective actions. To enable the Windows EMS Console: 1. In the BIOS Setup Utility, press to navigate to the Advanced menu. 2. Press to scroll to the EMS Console Configuration menu. Press the Enter key HP ProLiant DL145 Server User Guide

80 Operating System Installation and Software 3. Do one of the following: Press + to toggle the setting to Enabled. Press the Enter key. The Options box appears. Press or to select Enabled. Press the Enter key. 4. Press Esc to return to the previous screen or press F10 to save the changes and exit Setup. To view Windows EMS and perform basic management tasks: 1. Establish serial communication to the server as described in Configuring Access Through the Serial Port in this chapter. 2. Reboot the server. As the server boots, the Windows startup displays on the host computer monitor. 3. At the >SAC prompt, do one of the following: Enter? for a list of general commands. Enter ch -? for a list of channel management commands. Using the Watch Dog Timer The Watch Dog Timer increases server availability by resetting the server, powering down the server, or cycling the server power within a specified time after a system hang or period of inactivity. This functionality requires operating system support from a third-party IPMI product. To configure the Watch Dog Timer: 1. In the BIOS Setup Utility, press to navigate to the Advanced menu. 2. Press to scroll to the Management Processor Configuration menu. Press the Enter key. 3. Press to scroll to the Watch Dog Timer Action option. 4. Do one of the following: Press + or - to toggle the settings. Press the Enter key. The Options box appears. Press or to select the appropriate setting. Press the Enter key to select the appropriate option. The available options include: Disabled Reset System Power Down Power Cycle 5. Press to scroll to the MgmtProcessor WatchDog TimeOut option. NOTE: This option does not appear if the Watch Dog Timer is set to Disabled. HP ProLiant DL145 Server User Guide 5-25

81 Operating System Installation and Software System Event Log 6. Do one of the following: Press + or - to toggle the settings. Press the Enter key. The Options box appears. Press or to select the appropriate setting. Press the Enter key to select the appropriate option. The available options include: 5 min 1 min 30 sec 10 sec 7. Press the Esc key to return to the previous screen or press the F10 key to save the changes and exit Setup. The System Event Log lists a short description of each system event. Events that are recorded include system resets, system power loss, user logins, and unsuccessful login attempts. To use the System Event Log: 1. In the BIOS Setup Utility, press to navigate to the Advanced menu. 2. Press to scroll to the Event Log Control menu. Press the Enter key. 3. Do one of the following: Press + or - to toggle the settings. Press the Enter key. The Options box appears. Press or to select the appropriate setting. Press the Enter key to select the appropriate option. 4. Press to scroll to the following available options: The available options include: View Event Log Mark all events as read Clear Event Log Event Log Statistics 5. Press the Enter key to view the options. 6. Press the Esc key to return to the previous screen or press the F10 key to save the changes and exit Setup. NOTE: The System Event Log can also be viewed by entering the selread command at the Management Processor CLI HP ProLiant DL145 Server User Guide

82 Operating System Installation and Software Systems Insight Manager HP Systems Insight Manager runs on a console and monitors ProLiant 300/500/700 units. HP Systems Insight Manager also monitors basic information on a ProLiant 100 server running Windows and provides system inventory and configuration information. The new system management tool uses industry standards, WBEM and WMI management protocols, to provide this essential functionality. You can download the HP Systems Insight Manager software, as well as the HP Systems Insight Manager Installation and User Guide at IPMI System Management The ProLiant DL145 server is IPMI v1.5 compliant. The IPMI specification defines messages and system interfaces to platform management hardware. HP ProLiant DL145 Server User Guide 5-27

83 A Regulatory Compliance Notices Regulatory Compliance Model Number For the purpose of regulatory compliance certifications and identification, your product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product. Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or FCC ID on the label. Class A devices do not have an FCC logo or FCC ID on the label. After the Class of the device is determined, refer to the corresponding statement in the following sections. Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. HP ProLiant DL145 Server User Guide A-1

84 Regulatory Compliance Notices Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help. Declaration of Conformity for Products Marked with the FCC Logo, United States Only This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding your product, contact us by mail or telephone: Hewlett-Packard Company P. O. Box , Mail Stop Houston, Texas (For continuous quality improvement, calls may be recorded or monitored.) For questions regarding this FCC declaration, contact us by mail or telephone: Hewlett-Packard Company P. O. Box , Mail Stop Houston, Texas To identify this product, refer to the part, regulatory model, or model number found on the product. A-2 HP ProLiant DL145 Server User Guide

85 Regulatory Compliance Notices Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user s authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations. Canadian Notice (Avis Canadien) Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B Equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Mouse Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation HP ProLiant DL145 Server User Guide A-3

86 Regulatory Compliance Notices European Union Notice Japanese Notice Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (the equivalent international standards are in parenthesis): EN55022 (CISPR 22) Electromagnetic Interference EN55024 (IEC , 3, 4, 5, 6, 8, 11) Electromagnetic Immunity EN (IEC ) Power Line Harmonics EN (IEC ) Power Line Flicker EN60950 (IEC950) Product Safety BSMI Notice A-4 HP ProLiant DL145 Server User Guide

87 Regulatory Compliance Notices Laser Compliance This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC The product does not emit hazardous laser radiation. WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product s installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation: Do not try to open the module enclosure. There are no user-serviceable components inside. Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. Allow only HP Authorized Service technicians to repair the unit. Battery Replacement Notice Your computer is equipped with an internal lithium battery or battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Unless specific replacement instructions are provided as part of this guide, replacement is to be done by an authorized service provider using the HP spare designated for this product. For more information about battery replacement or proper disposal, contact your authorized reseller or your authorized service provider. WARNING: Your computer contains an internal lithium battery or battery pack. There is risk of fire and burns if the battery pack is not properly handled. To reduce the risk of personal injury: Do not attempt to recharge the battery. Do not expose to temperatures higher than 60 C. Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water. Replace only with the HP spare designated for this product. Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, please use the public collection system or return them to HP, your authorized HP partners, or their agents. HP ProLiant DL145 Server User Guide A-5

88 B Electrostatic Discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. Preventing Electrostatic Damage To prevent electrostatic damage, observe the following precautions: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Grounding Methods There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ± 10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. Use heel straps, toe straps, or bootstraps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. HP ProLiant DL145 Server User Guide B-1

89 Electrostatic Discharge Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. NOTE: For more information on static electricity or for assistance with product installation, contact your authorized reseller. B-2 HP ProLiant DL145 Server User Guide

90 C System Battery The server has a memory device that requires a battery to retain stored information. Battery Replacement When the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is usually about 5 to 10 years. To install a new battery: 1. Power down the server. Refer to Powering Down the Server in Chapter 2, Server Operations. 2. Extend the server from the rack. Refer to Extending the Server from the Rack in Chapter 2, Server Operations. 3. Remove the access panel. Refer to Removing the Access Panel in Chapter 2, Server Operations. 4. Locate the battery. To locate the battery refer to Chapter 1, Server Component Identification. 5. Remove the existing battery. Figure C-1: Removing a battery HP ProLiant DL145 Server User Guide C-1

HP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition)

HP BIOS Serial Console User Guide. Part Number March 2003 (Second Edition) HP BIOS Serial Console User Guide Part Number 306147-002 March 2003 (Second Edition) 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

HP ProLiant DL320 Generation 4 Server User Guide

HP ProLiant DL320 Generation 4 Server User Guide HP ProLiant DL320 Generation 4 Server User Guide November 2005 (First Edition) Part Number 394179-001 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide. April 2004 (First Edition) Part Number

HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide. April 2004 (First Edition) Part Number HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide April 2004 (First Edition) Part Number 359539-001 Copyright 2004 Hewlett-Packard Development Company, L.P. The information contained

More information

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide May 2003 (Third Edition) Part Number 291916-003 2003 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are

More information

ProLiant ML350 Tower-to-Rack Conversion Guide. First Edition (September 2000) Part Number Compaq Computer Corporation

ProLiant ML350 Tower-to-Rack Conversion Guide. First Edition (September 2000) Part Number Compaq Computer Corporation ProLiant ML350 Tower-to-Rack Conversion Guide First Edition (September 2000) Part Number 201346-001 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation Compaq, ProLiant, and the Compaq

More information

HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide. September 2003 (Fourth Edition) Part Number

HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide. September 2003 (Fourth Edition) Part Number HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide September 2003 (Fourth Edition) Part Number 293948-004 2003 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows

More information

HP ProLiant DL320 Generation 5 Server User Guide

HP ProLiant DL320 Generation 5 Server User Guide HP ProLiant DL320 Generation 5 Server User Guide September 2006 (First Edition) Part Number 419196-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

HP ProLiant BL40p Server Blade Setup and Installation Guide. January 2004 (Second Edition) Part Number

HP ProLiant BL40p Server Blade Setup and Installation Guide. January 2004 (Second Edition) Part Number HP ProLiant BL40p Server Blade Setup and Installation Guide January 2004 (Second Edition) Part Number 307153-002 Copyright 2003, 2004 Hewlett-Packard Development Company, L.P. The information contained

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide. January 2003 (Second Edition) Part Number

HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide. January 2003 (Second Edition) Part Number HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide January 2003 (Second Edition) Part Number 252621-002 2001, 2003 Hewlett-Packard Development Company, L.P. Microsoft, Windows,

More information

hp uninterruptible power system r12000 xr models installation instructions

hp uninterruptible power system r12000 xr models installation instructions hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer

More information

HP ProLiant 100 Series Servers User Guide

HP ProLiant 100 Series Servers User Guide HP ProLiant 100 Series Servers User Guide for HP ProLiant DL140 and DL145 Generation 2 Servers March 2005 (First Edition) Part Number 384049-001 Copyright 2005 Hewlett-Packard Development Company, L.P.

More information

HP ProLiant DL585 Server User Guide. July 2004 (Third Edition) Part Number

HP ProLiant DL585 Server User Guide. July 2004 (Third Edition) Part Number HP ProLiant DL585 Server User Guide July 2004 (Third Edition) Part Number 358707-003 2004 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation

More information

ProLiant ML350 Setup and Installation Guide

ProLiant ML350 Setup and Installation Guide ProLiant ML350 Setup and Installation Guide First Edition (September 2000) Part Number 201345-001 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation Compaq, Compaq Insight Manager, ProLiant,

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

HP ProLiant ML570 Generation 2 Server Setup and Installation Guide. October 2002 (Second Edition) Part Number

HP ProLiant ML570 Generation 2 Server Setup and Installation Guide. October 2002 (Second Edition) Part Number HP ProLiant ML570 Generation 2 Server Setup and Installation Guide October 2002 (Second Edition) Part Number 223960-002 Microsoft, MS-DOS, Windows, and Windows NT are trademarks of Microsoft Corporation

More information

HP ProLiant DL385 Server Maintenance and Service Guide. January 2005 (First Edition) Part Number

HP ProLiant DL385 Server Maintenance and Service Guide. January 2005 (First Edition) Part Number HP ProLiant DL385 Server Maintenance and Service Guide January 2005 (First Edition) Part Number 376533-001 Copyright 2005 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide. September 2003 (Fourth Edition) Part Number

HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide. September 2003 (Fourth Edition) Part Number HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide September 2003 (Fourth Edition) Part Number 293164-004 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows NT are U.S.

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

HP ProLiant ML570 Generation 4 Server User Guide

HP ProLiant ML570 Generation 4 Server User Guide HP ProLiant ML570 Generation 4 Server User Guide March 2006 (First Edition) Part Number 406862-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to

More information

HP BladeSystem c3000 Enclosure Setup and Installation Guide

HP BladeSystem c3000 Enclosure Setup and Installation Guide HP BladeSystem c3000 Enclosure Setup and Installation Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified

More information

HP ProLiant DL585 Generation 6 Server User Guide

HP ProLiant DL585 Generation 6 Server User Guide HP ProLiant DL585 Generation 6 Server User Guide Part Number 576361-002 September 2009 (Second Edition) Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation ProLiant CL380 Software User Guide Fourth Edition (December 2000) Part Number 157839-004 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation COMPAQ and the Compaq logo, Compaq Insight Manager,

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

HP ProLiant BL20p Generation 3 Server Blade Maintenance and Service Guide. July 2010 (Eleventh Edition) Part Number c

HP ProLiant BL20p Generation 3 Server Blade Maintenance and Service Guide. July 2010 (Eleventh Edition) Part Number c HP ProLiant BL20p Generation 3 Server Blade Maintenance and Service Guide July 2010 (Eleventh Edition) Part Number 316078-011c Copyright 2003, 2010 Hewlett-Packard Development Company, L.P. The information

More information

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks Guidelines June 2000 Prepared by: Storage Products Group Compaq Computer Corporation Contents Introduction...3 Rack Warnings...4 Telco Rack Option Kit for Compaq ProLiant DL360 Server Installation...5

More information

Replacing the Battery HP t5730 and t5735 Thin Clients

Replacing the Battery HP t5730 and t5735 Thin Clients Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows

More information

HP ProLiant SL160z G6 Server

HP ProLiant SL160z G6 Server HP ProLiant SL160z G6 Server Installation Instructions Part Number 571291-004 Item Description 7 UID LED/SW 8 PCI Slot 9 Health LED 10 Power Button Rear Panel Components Figure 2 Rear panel components

More information

HPE ProLiant ML30 Gen9 Server User Guide

HPE ProLiant ML30 Gen9 Server User Guide HPE ProLiant ML30 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

HPE BladeSystem c3000 Enclosure Quick Setup Instructions HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the

More information

HP ProLiant DL360 G7 Server User Guide

HP ProLiant DL360 G7 Server User Guide HP ProLiant DL360 G7 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of

More information

HP ProLiant DL580 Generation 4 Server User Guide

HP ProLiant DL580 Generation 4 Server User Guide HP ProLiant DL580 Generation 4 Server User Guide November 2005 (First Edition) Part Number 407334-001 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

ProLiant DL380 Generation 2 Server Setup and Installation Guide. First Edition (May 2001) Part Number Compaq Computer Corporation

ProLiant DL380 Generation 2 Server Setup and Installation Guide. First Edition (May 2001) Part Number Compaq Computer Corporation ProLiant DL380 Generation 2 Server Setup and Installation Guide First Edition (May 2001) Part Number 203844-001 Compaq Computer Corporation Notice 2001 Compaq Computer Corporation Compaq, the Compaq logo,

More information

HP ProLiant DL360 G7 Server User Guide

HP ProLiant DL360 G7 Server User Guide HP ProLiant DL360 G7 Server User Guide Part Number 608341-004 October 2010 (Fourth Edition) Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

ProLiant 800 Servers Supporting Pentium II Processors and 100-MHz System Bus Setup and Installation Guide

ProLiant 800 Servers Supporting Pentium II Processors and 100-MHz System Bus Setup and Installation Guide ProLiant 800 Servers Supporting Pentium II Processors and 100-MHz System Bus Setup and Installation Guide First Edition (April 1998) Part Number 179489-001 Compaq Computer Corporation Notice The information

More information

HP ProLiant ML150 Gen9 Server User Guide

HP ProLiant ML150 Gen9 Server User Guide HP ProLiant ML150 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

HP Cluster Platform Server and Workstation Overview

HP Cluster Platform Server and Workstation Overview HP Cluster Platform Server and Workstation Overview HP Part Number: A-CPSOV-H Published: March 009 Copyright 009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to

More information

HP NetServer E 800 Installation Guide

HP NetServer E 800 Installation Guide HP NetServer E 800 Installation Guide HP Part Number D9394-90000 Printed June 2000 Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

HP ProLiant DL580 Generation 3 Server User Guide. April 2005 (Second Edition) Part Number

HP ProLiant DL580 Generation 3 Server User Guide. April 2005 (Second Edition) Part Number HP ProLiant DL580 Generation 3 Server User Guide April 2005 (Second Edition) Part Number 379044-002 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

HP ProLiant ML350 Generation 4 Server Maintenance and Service Guide. August 2004 (Second Edition) Part Number

HP ProLiant ML350 Generation 4 Server Maintenance and Service Guide. August 2004 (Second Edition) Part Number HP ProLiant ML350 Generation 4 Server Maintenance and Service Guide August 2004 (Second Edition) Part Number 356698-002 2004 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

HP ProLiant DL160 Gen8 Server User Guide

HP ProLiant DL160 Gen8 Server User Guide HP ProLiant DL160 Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

HP ProLiant DL100 Series Server User Guide

HP ProLiant DL100 Series Server User Guide HP ProLiant DL100 Series Server User Guide for HP ProLiant DL120 G6 Servers Part Number 579574-001 October 2009 (First Edition) Copyright 2009 Hewlett-Packard Development Company, L.P. The information

More information

HP ProLiant DL585 Server. Maintenance and Service Guide

HP ProLiant DL585 Server. Maintenance and Service Guide HP ProLiant DL585 Server Maintenance and Service Guide Part number: 358708-009 Ninth edition: May 2006 Legal notices Copyright 2004 2006 Hewlett-Packard Development Company, L.P. The information contained

More information

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007 Sun StorageTek nl 1U Rackmount Media Tray Reference Guide Sun Doc Part Number: 875 4297 10 Second edition: December 2007 Legal and notice information Copyright 2007 Hewlett Packard Development Company,

More information

HP ProLiant BL280c G6 Server Blade User Guide

HP ProLiant BL280c G6 Server Blade User Guide HP ProLiant BL280c G6 Server Blade User Guide Abstract This document describes installation, administration, and troubleshooting for this server blade. This document is for the person who installs, administers,

More information

HP ProLiant DL380 Generation 4 Server Maintenance and Service Guide

HP ProLiant DL380 Generation 4 Server Maintenance and Service Guide HP ProLiant DL380 Generation 4 Server Maintenance and Service Guide March 2006 (Seventh Edition) Part Number 359226-007 Copyright 2004, 2006 Hewlett-Packard Development Company, L.P. The information contained

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

HP BladeSystem c-class Enclosure Troubleshooting Guide

HP BladeSystem c-class Enclosure Troubleshooting Guide HP BladeSystem c-class Enclosure Troubleshooting Guide Part Number 460224-002 July 2009 (Second Edition) Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

HPE ProLiant ML150 Gen9 Server User Guide

HPE ProLiant ML150 Gen9 Server User Guide HPE ProLiant ML150 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

HPE ProLiant DL20 Gen9 Server User Guide

HPE ProLiant DL20 Gen9 Server User Guide HPE ProLiant DL20 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

Hardware Reference Guide HP Compaq t5000 Thin Client

Hardware Reference Guide HP Compaq t5000 Thin Client Hardware Reference Guide HP Compaq t5000 Thin Client Document Part Number: 334457-004 February 2005 This book provides basic hardware information for this series of thin clients. Å WARNING: Ä CAUTION:

More information

HP ProLiant DL100 Series Server User Guide

HP ProLiant DL100 Series Server User Guide HP ProLiant DL100 Series Server User Guide for HP ProLiant DL120 G6 Servers Part Number 579574-003 March 2010 (Third Edition) Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information

More information

HP ProLiant DL385 Generation 5 Server User Guide

HP ProLiant DL385 Generation 5 Server User Guide HP ProLiant DL385 Generation 5 Server User Guide Part Number 457041-001 November 2007 (First Edition) Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

ProLiant DL320 Setup and Installation Guide. First Edition (September 2000) Part Number Compaq Computer Corporation

ProLiant DL320 Setup and Installation Guide. First Edition (September 2000) Part Number Compaq Computer Corporation ProLiant DL320 Setup and Installation Guide First Edition (September 2000) Part Number 203836-001 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation. Compaq, ProLiant, Fastart, Compaq

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

HP ProLiant BL260c Generation 5 Server Blade User Guide

HP ProLiant BL260c Generation 5 Server Blade User Guide HP ProLiant BL260c Generation 5 Server Blade User Guide Part Number 459407-001 March 2008 (First Edition) Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

HP ProLiant MicroServer Gen8 User Guide

HP ProLiant MicroServer Gen8 User Guide HP ProLiant MicroServer Gen8 User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

HP ProLiant DL320e Gen8 v2 Server User Guide

HP ProLiant DL320e Gen8 v2 Server User Guide HP ProLiant DL320e Gen8 v2 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

HPE ProLiant DL580 Gen10 Server

HPE ProLiant DL580 Gen10 Server HPE ProLiant DL580 Gen10 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots HPE server systems. Hewlett Packard Enterprise assumes you are qualified

More information

350 East Plumeria Drive San Jose, CA USA May

350 East Plumeria Drive San Jose, CA USA May Installation Guide 350 East Plumeria Drive San Jose, CA 95134 USA May 2012 201-15135-02 NETGEAR, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored

More information

HPE ProLiant DL580 Gen10 Server User Guide

HPE ProLiant DL580 Gen10 Server User Guide HPE ProLiant DL580 Gen10 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots HPE server systems. Hewlett Packard Enterprise assumes that you are qualified

More information

ReadyNAS OS 6 Rack-Mount Hardware Manual

ReadyNAS OS 6 Rack-Mount Hardware Manual Rack-Mount Hardware Manual Model ReadyNAS 2120 ReadyNAS 2120 v2 ReadyNAS 3130 ReadyNAS 3138 ReadyNAS 3220 ReadyNAS 3312 ReadyNAS 4220 ReadyNAS 4312 ReadyNAS 4360 April 2017 202-11272-08 350 E. Plumeria

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

HP ProLiant BL490c G7 Server Blade User Guide

HP ProLiant BL490c G7 Server Blade User Guide HP ProLiant BL490c G7 Server Blade User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

HP ProLiant DL120 G7 Server User Guide

HP ProLiant DL120 G7 Server User Guide HP ProLiant DL120 G7 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced IT professionals

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, Windows Vista, and Windows

More information

HPE Intelligent Power Distribution Unit Installation Instructions

HPE Intelligent Power Distribution Unit Installation Instructions HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for

More information

HP ProLiant DL385p Gen8 Server User Guide

HP ProLiant DL385p Gen8 Server User Guide HP ProLiant DL385p Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

HP ProLiant DL320e Gen8 Server User Guide

HP ProLiant DL320e Gen8 Server User Guide HP ProLiant DL320e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced IT

More information

HP ProLiant DL/ML370 G6 Server User Guide

HP ProLiant DL/ML370 G6 Server User Guide HP ProLiant DL/ML370 G6 Server User Guide Part Number 513482-001 March 2009 (First Edition) Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

HP StorageWorks Modular Smart Array 500 Generation 2 Storage System User Guide. March 2005 (Second Edition) Part Number

HP StorageWorks Modular Smart Array 500 Generation 2 Storage System User Guide. March 2005 (Second Edition) Part Number HP StorageWorks Modular Smart Array 500 Generation 2 Storage System User Guide March 2005 (Second Edition) Part Number 354906-002 Copyright 2004, 2005 Hewlett-Packard Development Company, L.P. The information

More information

HP ProLiant DL60 Gen9 Server User Guide

HP ProLiant DL60 Gen9 Server User Guide HP ProLiant DL60 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

HP ProLiant DL320e Gen8 Server User Guide

HP ProLiant DL320e Gen8 Server User Guide HP ProLiant DL320e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced IT

More information

HPE ProLiant ML350 Gen9 Server User Guide

HPE ProLiant ML350 Gen9 Server User Guide HPE ProLiant ML350 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Windows is a U.S. registered trademark of

More information

HP ProLiant DL585 G7 Server User Guide

HP ProLiant DL585 G7 Server User Guide HP ProLiant DL585 G7 Server User Guide Part Number 617692-001 May 2010 (First Edition) Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without

More information

HPE ProLiant DL380 Gen10 Server User Guide

HPE ProLiant DL380 Gen10 Server User Guide HPE ProLiant DL380 Gen10 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are

More information

Aruba JL311A Cable Guard Installation Instructions

Aruba JL311A Cable Guard Installation Instructions Aruba JL3A Cable Guard Installation Instructions Abstract Use this guide to assist in the basic installation of the Aruba JL3A Cable Guard on select Aruba 8 port switches. *500-97* Part Number: 500-97

More information

LifeSize ClearSea Installation Guide August 2012

LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea LifeSize ClearSea Virtual Machine LifeSize ClearSea Installation Guide 2 LifeSize ClearSea This guide describes how to install and configure

More information

HPE ProLiant DL80 Gen9 Server User Guide

HPE ProLiant DL80 Gen9 Server User Guide HPE ProLiant DL80 Gen9 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified

More information

HP ProLiant DL388e Gen8 Server User Guide

HP ProLiant DL388e Gen8 Server User Guide HP ProLiant DL388e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

HP ProLiant DL380p Gen8 Server User Guide

HP ProLiant DL380p Gen8 Server User Guide HP ProLiant DL380p Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

HPE ProLiant DL380e Gen8 Server User Guide

HPE ProLiant DL380e Gen8 Server User Guide HPE ProLiant DL380e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are

More information

HP BladeSystem c3000 Tower Enclosure Setup and Installation Guide

HP BladeSystem c3000 Tower Enclosure Setup and Installation Guide HP BladeSystem c3000 Tower Enclosure Setup and Installation Guide Part Number 457022-002 August 2008 (Second Edition) Copyright 2007, 2008 Hewlett-Packard Development Company, L.P. The information contained

More information

HP ProLiant ML350 Generation 4p Server Maintenance and Service Guide

HP ProLiant ML350 Generation 4p Server Maintenance and Service Guide HP ProLiant ML350 Generation 4p Server Maintenance and Service Guide July 2006 (Second Edition) Part Number 382586-002 Copyright 2005, 2006 Hewlett-Packard Development Company, L.P. The information contained

More information

HP ProLiant BL495c Generation 5 Server Blade User Guide

HP ProLiant BL495c Generation 5 Server Blade User Guide HP ProLiant BL495c Generation 5 Server Blade User Guide Part Number 491030-003 April 2009 (Third Edition) Copyright 2008, 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

HP ProLiant WS460c G6 Workstation Blade with WS460c Graphics Expansion Blade User Guide

HP ProLiant WS460c G6 Workstation Blade with WS460c Graphics Expansion Blade User Guide HP ProLiant WS460c G6 Workstation Blade with WS460c Graphics Expansion Blade User Guide Abstract This guide provides operation information for the HP ProLiant WS460c G6 Workstation Blade with WS460c Graphics

More information

HPE ProLiant MicroServer Gen10 Troubleshooting Guide

HPE ProLiant MicroServer Gen10 Troubleshooting Guide HPE ProLiant MicroServer Gen10 Troubleshooting Guide Abstract This document describes common procedures and solutions for troubleshooting the HPE ProLiant MicroServer Gen10. This document is intended for

More information